AC Leakage current transformers
PART NUMBERS
. 7 - 1
FEATURES
APPLICATIONS
SPECIFICATIONS
• Center hole-through, easy installation,on the safe side. • Metal casing,better capacity of resisting disturbance,be adequate for inside and outside surroundings. • High-sensitivity/accuracy,good linearity. • Two series for selection: passive and active
• Used in high voltage electric power equipment insulation monitoring plant, which is stalled in transformers station. Provide exact measurement for mA leakage current of high voltage power equipment, such as transformers sleeve, current transformers
• Frequency:50Hz • Rated current:10mA、20mA、30mA • Measuring range:0.5~700mA • Output signal:mV/mA • Amplitude error:±0.1% • Phase error:±1' • Environmental temperature:一30º C~+75º C Influence on phase error by temperature change is<1’ • Diameter of primary center hole:Φ13mm, 25mm, 40mm, 50mm
TA
Rated Output Current
Rated Input Current
Casing Number
AC Leakage C
T’s
Phone: +86-533-381-8450 Fax: +86-533-381-8724
AC Leakage current transformers
25XL
YUANXING TA25LXX Series of AC Leakage current transformers Base theory of zero flux, TA25LXX series is used for online insulation monitoring device of high-voltage electric equipment in electric substation, which can exactly transit mA AC leakage current.
YUANXING can designe and manufacture to meet the spe-cific design challenges of the client’s specific application. The following models are only a small sampling of the manydifferent products which have been and are currently being manufactured.
TA25XL
SHANDONG YUANXING Electronics Co.,Ltd.NO.39, QIXIN AVENUE, ZHANGDIAN, ZIBO, SHANDONG, CHINA 255095
. 7 - 2
AC Leakage C
T’s
Phone: +86-533-381-8450 Fax: +86-533-381-8724
元星电子YUANXING
AC Leakage current transformers
PERFORMANCES
OUTLINE DRAWING
45.5 ±0.2
H
2-6.5X1.5
W
B
A
L
TA25L
H56
±0.2
34 ±0.2
A
B(L)4
4-5x2.5
46W
45
TA25CL
H
±0.2
4-
±0.2
6.5
2175
W
A
B(L)
TA25DL
TA25EL±0.295 6
8
76
±0.2W
7648±0.2
L
A
B(H)
2
L
H A
W
TA25BL
TA25BL 10~100
TA25CL
1000 :150/60
50/60
0 16.0-50-44-54.8
25.5-68-65.5-72
TA25DL
TA25EL
50/60
50/60 0.020.05
40.5-88-48-91
50-105-86-100
0.020.05
0.020.05
0.020.05
0
0
0
2000 :1
1000 :12000 :1
1000 :12000 :1
1000 :12000 :1
10~1000
10~1000
10~1000
TA25L 10~1001000 :1
50/60 0 12.4-58-43-560.020.052000 :1
Frequency Rated burdenNumber Outline dimension( Hz)
(mm)Accuracy class
Rated Input(mA)
Ratio ID-L-W-H (ohms)
SHANDONG YUANXING Electronics Co.,Ltd.NO.39, QIXIN AVENUE, ZHANGDIAN, ZIBO, SHANDONG, CHINA 255095
. 7 - 3
AC Leakage C
T’s
Phone: +86-533-381-8450 Fax: +86-533-381-8724
元星电子YUANXING
AC Leakage current transformers
OUTLINE DIMENTIONUnit:mm (inch)
TA25BL
TA25CL
50.0
(1.969)
44.0
(1.732)
54.8
(2.157)
12.4
(0.488)
53.0
(2.087)
68.0(2.677)
25.5(1.004)
68.0(2.677)
65.5(2.579)
72.0(2.835)
TA25DL
TA25EL
88.0
(3.465)
48.0
(1.890)
91.0
(3.583)
40.5
(1.594)
88.0
(3.465)
105.0(4.134)
50.0(1.969)
100.0(3.937)
86.0(3.386)
100.0(3.937)
L W H A B
TA25L58.0
(2.283)
43.0
(1.693)
56.0
(2.205)
12.4
(0.488)
53.0
(2.087)
Part number
SHANDONG YUANXING Electronics Co.,Ltd.NO.39, QIXIN AVENUE, ZHANGDIAN, ZIBO, SHANDONG, CHINA 255095