    Power Quality tools

    for industrial andcommercial applications.

    Troubl

    eshooters L

    oggers

    Recorders

    actoolsupply.com

    actoolsupply.com

    actoolsupply.com

    Fluke 437-II 400 Hertz Power Quality Energy Analyzer

    http://www.aikencolon.com/fluke-437-ii-series-ii-power-quality-energy-analyzerhttp://www.aikencolon.com/http://www.aikencolon.com/Fluke-Test-Equipment_c_577.htmlhttp://www.aikencolon.com/fluke-437-ii-series-ii-power-quality-energy-analyzer
  • 8/11/2019 AC Fluke Power Quality Brochure

    2/8

    What is power quality?How reliably can your systemsoperate their loads? That isthe essence of power quality.Power disturbances can involvevoltage, current, or frequencyand typically manifest as dips,swells, harmonic distortion,unbalance, flicker, and tran-sients. These problems can orig-inate in your own power system

    or from the utility. Defined interms of magnitude and dura-tion, power disturbances canlast microseconds, or involveoutages of hours or more.

    Power quality overview

    The costs of poor power qualityThe increasing cost of electricalenergy is driving industries to useenergy as efficiently as possible. Flukepower and energy measuring tools area vital component in gaining controlof those costs. The traditional way ofreducing energy usage is monitoringand targeting (M & T); Monitoring andtargeting determines when and whereenergy is being used, and by doing sodiscovers whether or not that energyis being used effectively. Examplesof this include comparing buildingoccupancy with energy profiles.Simple things like ensuring lightingand heating systems are not being op-erated when a building is unoccupiedcan create significant savings. Otherexamples of energy waste include thepowering of machinery and plantswhen no production is taking place,and leaving equipment in standbymode for extended periods of time.The power and energy logging capa-bilities in Fluke Power Quality toolsenable the user to monitor and targetenergy usage to identify these savings

    opportunities.Another way of determining whetheror not electrical equipment is operat-ing efficiently is to identify potentialpower quality issues. Poor power qual-ity is expensive. First and foremost, itpushes up your energy costs both fromexcess power usage, and in penaltiesyour utility may assess for poor powerfactor or high peak demands.

    Poor power quality also takes a tollon equipment, increasing the cost ofmaintenance and repairs. Prematureequipment failures or damage caused

    by power problems result not only inthe expense of replacing the equip-ment itself, but also in associatedlabor costs for diagnosis and repair.

    When equipment is not operatingdue to unscheduled downtime, pro-ductivity drops and process consisten-cy suffers or fails, which in turn leadsto product waste. Flukes Power Qualitytools provide the means to discoverthe source and magnitude of powerquality issues allowing savings oppor-tunities to be identified and capital-ized upon. Taking these capabilities

    one step further, the Fluke 430 Series

    II Power Quality and Energy Analyz-ers will quantify the actual fiscal costof wasted energy due to poor powerquality, ultimately saving money interms of your energy bill and theeffects of unplanned downtime.

    How do you know you havepower quality problems?

    Youll easily recognize the symptoms:flickering lights, power outages,nuisance tripping of breakers, PLCsand variable speed drives. Equipmentsuch as motors and transformers willrun hot or noisy. Some problems are

    more subtle such as poor computerperformance, causing lock-ups anddata loss. All of these problemsdrive up your utility bills and drivedown efficiency.

    Where do power qualityproblems originate?

    You might not realize that more than80 percent of all power quality prob-lems originate within your facility.

    Large equipment starting-up orshutting down, improper wiring andgrounding, and overloaded circuitsor harmonics are just a few of theculprits. Less than 20 percent of powerproblems originate with the utilitytransmission and distribution system.Lightning strikes, equipment failure,accidents, and weather conditionsall adversely affect the utility. Neigh-boring businesses, and normaloperation of utility equipment canalso affect the quality of power deliv-ered to your facility.

    Take a pro-active approachYou have the power to improve powerquality. Your frontline of defense isregular and frequent inspection of yourfacility with good maintenance prac-tices, using the right inspection equip-ment. Thats where Fluke can help.

    actoolsupply.com

    actoolsupply.com

  • 8/11/2019 AC Fluke Power Quality Brochure

    3/8

    Fluke tools will help you troubleshoot,record, and analyze power quality andenergy parameters with speed andconfidence. Get detailed information Locate a variety of disturbance sources Correctly diagnose problems Prevent problems

    Every Fluke energy optimization andpower quality tool is a solutionbeginning with an intuitive user in-terface that makes advanced featureseasy to access. Flexible and powerfulsoftware is included with each tool, atno extra cost.

    Fluke offers a comprehensive lineof troubleshooters, power and energyloggers, and recorders to handle abroad range of power quality applica-tions. But how do you know whichtool is right for which job? Use thequick reference guide below to identifythe right tool for the problems youreexperiencing.

    TroubleshootersThese instruments include a livedisplay when immediate access tothe diagnostic information is needed.

    Whenever a recurring problemexists (such as overheatingtransformers and motors, andnuisance tripping of breakers).

    On-site electrician or electricaltechnician

    LoggersLoggers are the basic tools for creat-ing energy usage profiles used inmonitoring and targeting. You canalso use a power quality logger tovalidate voltage quality and look forgeneral trends in the power quality.

    When you need to know the loadingon a system, or to understand thegeneral quality of service.

    Power quality specialist, on-siteelectrician or electrical technician,

    engineer facilities technicians andhigh-end electrical contractors, com-missioners

    Recorders

    Many problems cant be foundimmediately, especially those causedby different loads interacting. Usethese instruments to record indepthvoltage and current information overtime, so you can better diagnose andresolve problems.

    When intermittent voltagedisturbances or high-speedtransients cause problems.

    R&D engineer, facility manager,plant manager, electrician

    Why use one?

    When?

    Who?

    Out-of-the-box solutions for energyoptimization and power quality

    actoolsupply.com

    actoolsupply.com

  • 8/11/2019 AC Fluke Power Quality Brochure

    4/8

    A Frontline troubleshootingand predictive maintenance

    In these applications, a memberof the facilitys maintenance teamresponds to failures that may result indowntime.

    When the facility is down it isnot generating revenue, so there isextreme urgency to get these prob-lems identified so operations can berestored as quickly as possible. Withequipment down, the maintenancetech wants to see information aboutthe problem right on the screen of

    the toolas opposed to recordingit and then analyzing the data laterwith a PC.

    Symptoms include: Overheating transformers Overheating motors Reduced operating life of motors

    and transformers Control system problems

    (PLCs tripping) Nuisance tripping of circuit

    breakers

    B Load studies

    Before the installation of newequipment or major distributionchanges, load studies are conductedto determine if the system hasenough electrical capacity to handlethe proposed loads.

    The three groups that mayconduct a load study include: Electrical contractorswho have

    been hired to install newequipment.

    The maintenance teamif theyare installing equipment.

    The utilitywhen a new facility

    is being built and there is aneed to determine what trans-

    formers and other equipmentwill be needed to meet powerrequirements.

    In the US, regulation NEC 220.87

    defines how to properly perform a

    load study in order to obtain an

    electrical permit.

    Recognizing, identifying, and solvingpower quality problems is increasinglyimportant to businessesso buildingthis essential knowledge will helpyou get to the next level. You can counton Fluke to bring you the understandingand the proven tools you need.

    Count on Fluke to help you find,fix, and prevent power qualityproblems

    When you need to identify and solveyour electrical problems fast, Fluke hasthe tool for the job. New to energy optimization and

    power quality?Fluke offers intuitiveand safe troubleshooting tools withonline seminars and application notesto help you get started.

    Seasoned pro?Fluke has theadvanced products and industrycase studies to match your mostdemanding problems.

    Industrial and commercial building applications

    C Energy surveysThe goal of an energy survey is toreduce the electrical energy usage.

    Simple monitoring and targetingcan discover savings opportuni-ties by comparing daily and weeklyenergy usage profiles with facilitiesactivities. Monitoring and targetingcan also pinpoint reductions in peakdemand charges and power factorpenalties.

    An energy survey is performed overwhatever period of time captures arepresentative energy profile of the

    business in question. This could bea day, week, or month depending onindustry. The facility uses the resultsof the survey to guide improvementsin energy consumption, such asinstalling high efficiency equipmentor correcting power factor. The testwill then be repeated to validate thebenefit of the changes.

    Flukes new UnifiedPower Measurement(UPM) capability can alsodiscover energy wastedue to specific power

    quality issues such asharmonics and unbal-ance. UPM specificallydetails the energywasted due to thepresence of thesepower quality issues.By reducing harmonicsand unbalance you canreduce the overallamount of energy used.

    actoolsupply.com

    actoolsupply.com

  • 8/11/2019 AC Fluke Power Quality Brochure

    5/8

    D Voltage qualityCustomers expect their utilities to supplyvoltage that meets a minimum level ofquality to allow their facilities to runwithout problems. When a customerexperiences a voltage quality issue, theyoften assume that the utility is at fault,so the customer or the utility will use atool to validate the voltage qualityat the service entrance. In Europea standard for voltage quality has beenestablished: EN 50160. Many countriesoutside of Europe accept this standardas well. If the utility is ruled out as thesource of the problem, the next step isto conduct voltage quality tests insidethe facility and at the load.

    Symptoms of voltage qualityproblems include: Flickering lights Tripping/resets UPS cycling

    E Long-term and intermittentanalysisMany times, the problem cannot beidentified immediately. It could be theinteraction of different loads on the

    power system causing the problem. Inthis case, an instrument that can recordvoltage and current information overtime helps the user more easily diag-nose the disturbance. These tests oftenuse a series of instruments, recordingat multiple locations simultaneously topinpoint the root cause of the distur-bance. Tests can last for months whilepersonnel wait for the symptom to occurso they can correlate it to the specificevent that caused the problem.

    Symptoms include: Intermittent voltage disturbances

    High speed transients

    actoolsupply.com

    actoolsupply.com

  • 8/11/2019 AC Fluke Power Quality Brochure

    6/8

    Fluke 345Power QualityClamp Meter

    Monitor electronic loads.Combining a power analyzer, powerquality logger, and clamp meter, theFluke 345 is ideal for commissioningand monitoring electronic loads.

    Set up and troubleshootvariable frequency drivesand UPS systemsAccurately measure key powerquality parameters. A low-pass filterremoves high frequency noise.

    Uncover harmonic issues thatdamage or disrupt equipmentAnalyze the harmonic spectrumgraphically, with the bright, color,power meter display, or digitally.

    Measure inrush current tocapture nuisance circuit-

    breaker trippingfrom 3 to300 seconds.

    Verify system capacity withload studiesbefore addingloads.

    Measure dc current up to2000 A without breaking thecircuit

    The Hall Effect clamp meter designmakes it possible.

    Analyze trends or catchintermittent problemswith long-term power quality monitoring.Monitor for minutes or months,including harmonics, with high-

    capacity internal memory.

    Measures three-phase balanceloads.

    600 V CAT IV safety rating foruse at the service entrance.

    Includes Power Log softwarefor generating reports and viewinggraphs.

    Fluke 43BPower Quality

    Analyzer

    Get control of power problems.Maintain power systems, troubleshootpower problems, and diagnoseequipment failures with one rugged,handheld tool. The Fluke 43B com-bines the most useful capabilities ofa power quality analyzer, multimeter,and scope.

    Combinesthe most useful capabili-ties of a power quality analyzer,multimeter and scope.

    Trendsvoltage, current, frequency,and power harmonics.

    Capturesvoltage sags, transients,and inrush current.

    Tracks intermittent problemsand power system performancewith monitoring functions. Recordstwo selectable parameters up to16 days.

    Calculates 3-phase poweronbalanced loads with a single-phasemeasurement.

    Measuresresistance, diode voltagedrop, continuity, and capacitance.

    6.5 hours of operating timewith

    new NiMH battery. Includes FlukeViewsoftware

    for logging readings over time including a complete harmonic profileup to the 51st harmonic.

    Fluke 430 Series IIThree-Phase Power Qualityand Energy Analyzers

    Pinpoint power quality problemsand monetize energy loss.The new 430 Series II analyzers offerthe best in power quality analysis,and introduce, for the first time ever,the ability to monetarily quantifylosses caused by power quality issues.Use for:

    Frontline troubleshootingQuickly diagnose problemson-screen to get your operationback online.

    Energy loss managementMeasure and quantify specificcauses of energy losses to enablesimple return-on-investmentcalculation of harmonics andunbalance mitigation equipment.

    Power inverter efficiencySimultaneously measure AC inputpower and DC output power forpower electronics systems.

    Capture fast RMS data, show half-cycle and waveforms to character-ize electrical system dynamics.

    Predictive maintenance

    Detect and prevent power qualityissues before they cause downtime.

    Quality of service complianceValidate incoming power qualityat the service entrance.

    Long-term analysis

    Uncover hard-to-find or intermittentissues.

    Load studies

    Verify electrical system capacitybefore adding loads.

    Dynamic load testing

    Capture instantaneous values tosee the effect of load switch ongenerators and UPS systems.

    Fluke VR1710Power QualityRecorder

    A simple plug-in voltage loggerto pinpoint whats happening atsingle phase outlets.Whether its loose connections ortransients caused by equipmentswitching or lightning strikes theVR1710 will find the problem. Powerquality parameters including rmsaverage, transients, flicker, and har-monics up to the 32nd, are recordedusing a user-selected average periodfrom one second to 20 minutes.

    Fast and easy recording ofvoltage trends, dropouts, andpower qualityEasily pinpoint the root cause ofsingle phase voltage problems.

    Continuous recording of allvalues with no gapsSave testing time by getting thewhole picture with one instrumentthat records both events and voltage.

    Min, Max, and Average rmsvalues (1/4 cycle) with timestampQuickly see what happened andwhen.

    Includes PowerLog softwarepackagefor quick download,analysis, and automatic reportingSave time by generating powerquality reports automatically withpre-set templates.

    LoggersTroubleshooters actoolsupply.com

    actoolsupply.com

  • 8/11/2019 AC Fluke Power Quality Brochure

    7/8

    Fluke 1735Three-Phase PowerLogger

    Study energy consumptionand loads.For electricians or technicians whoneed basic power quality logging.Set it up in seconds. Monitor andrecord most power parameters forup to 45 days.

    Load studiesVerify electrical system capacitybefore adding loads.

    Energy assessmentsQuantify energy consumptionbefore and after improvements tojustify energy-saving devices.

    Harmonics surveysCapture energy profiles to enableenergy optimization actions.

    Improve reliability by capturingvoltage eventsMonitor for dips and swells fromload switching that cause spuriousresets or nuisance circuit breakertripping.

    Includes Fluke Power LogsoftwareGenerate reports and view graphs.

    Fluke 1740 SeriesThree-Phase Power QualityLoggers Memobox

    Easy power quality logging.The everyday power meter for tech-nicians who need to troubleshootand analyze power quality issues.Simultaneously log up to 500 powerparameters for up to 85 days touncover intermittent and hard-to-findpower quality issues.

    Uncover root causes of equipmentmalfunctions.

    Check incoming power qualityat the service entrance.

    Establish a power qualitybaselineand check compatibilitywith critical systems before installingnew equipment.

    Load studiesVerify system capacity beforeadding loads.

    Energy assessmentsQuantify energy consumption,power factor, and overall powerquality before and after improve-

    ments, to validate performance.

    Installs inside the cabinetCompact, fully-insulated housing

    and accessories fit easily in tightspaces, next to live power.

    Includes PQ Log softwareQuickly analyzes trends, createsstatistical summaries, and generateddetailed graphs and tables.

    Fluke 1750Three-Phase Power QualityRecorder

    Threshold-free measurementensures youll never miss an event.Capture every measurement, everyevent, on every cycle, all the time.The Fluke 1750 makes it automatic.Excellent accuracy and resolutionprovide complete visibility into yourdistribution system.

    Long-term analysisUncover hard-to-find or intermit-

    tent issues.

    Power quality surveysQuantify power quality throughouta facility, documenting results withprofessional reports.

    Quality of service complianceValidate incoming power quality atthe service entrance.

    Portable monitoringMonitor critical equipment tocapture power quality events andcorrelate them with equipmentmalfunctions.

    Quick, reliable configurationAndroid based wireless tablet fontpanel interface provides a window

    into what the instrument is record-ing, even in awkward test locations.

    Threshold-free set-upApply thresholds after the datais collected.

    Plug and playSet up in minutes with self-

    identifying current probes andsimple lead voltage connections.

    Includes Intuitive PC softwareEasy-analysis and reportingof data with Fluke Power AnalyzeV2.1 software with automaticreport generation.

    Fluke 1760Three-Phase Power QualityRecorder Topas

    Class-A compliance for your mostdemanding power quality tests.For advanced power quality analysisand consistent compliance testingof industrial power distributionsystems. The Fluke 1760 is designedfor medium-voltage and low-voltagenetworks.

    Detailed disturbance analysisPerform high-speed transientanalysis and uncover root cause ofequipment malfunctions for mitiga-

    tion and predictive maintenance.Capture even very short impulsessuch as lightning strikes.

    Fully compliant to IEC61000-4-30 Class-AOffers indisputable verificationof incoming power quality at theservice entrance.

    Correlate events at multiplelocationsUse GPS time synchronizationto quickly detect where a fault firstoccurred, either inside or outsidethe facility.

    Galvanic separation anddc couplingMake complete measurementson dissimilar power systems. Forexample, you can troubleshootUPS systems by simultaneouslyrecordingthe battery voltage andpower output.

    Power quality and power loadstudiesAssess baseline power qualitytovalidate compatibility with criticalsystems before installation. Verifyelectrical system capacity beforeadding loads.

    Includes ComprehesivesoftwareFluke Power Analyze V2.1 software

    provides trend diagrams for rootcause analysis, statistical summariesreport writing, and real-time datamonitoring in the online mode.

    Recordersactoolsupply.com

    actoolsupply.com

  • 8/11/2019 AC Fluke Power Quality Brochure

    8/8

    Applications Troubleshooters Loggers Recorders

    345 43B 430 II 1710 1735 1740 1750 1760

    Frontline

    troubleshooting

    and predictive

    maintenance

    Load studies

    Energy surveys

    Voltage quality

    Long-term/inter-

    mittent analysis

    Energy

    monetization

    Single-phase Single-phase Three-phase Single-phase Three-phase Three-phase Three-phase Three-phase

    Learn more!

    Free Power Quality video Application Poster On-site demo

    Training

    i430 Thin Flex 4 Pak i5sPQ3, 5 A ac CurrentClamps, 3-pack

    GPS430-II TimeSynchronization Module

    Recommended applications

    actoolsupply.com

    actoolsupply com