Abbreviations General Roof Plan Notes General Plan...

10
Abbreviations Class A door architect/engineer Americans with Disabilities Act addendum administration above finished floor aluminum amount approximate apartment Architect Architect's Supplemental Instruction association assembly American Society for Testing and Materials avenue average Architectural Woodworking institute Class B door board below finished ceiling below finish floor bituminous building bulkhead boulevard Building Officials and Code Administrators Association International bottom bearing bearing plate basement cabinet chalk board ceramic base closed circuit television construction documents contract documents cement plaster cement plaster ceiling cast-in-place construction joint control joint center line ceiling ceiling height closet clear concrete masonry unit counter countertop column concrete concrete floor conference construction coordinate corridor carpet Construction Specifications Institute casement casework ceramic tile ceramic tile base ceramic tile floor center cubic feet cubic inch cubicle custodian Class D door datum decibel double double acting door double glaze degree degrees Celsius degrees Fahrenheit delete demolition department detail drinking fountain double hung (door, window) diameter diagonal diffuser dimension direction dispenser division double joist down door down spout drawing drawer Class E door each Electrical Contractor exterior finish system exterior insulation and finish system expansion joint elevation electric elevator emergency enamel enclosure entrance edge of slab ethylene propylene diene monomer equal equipment equivalent escalator easement estimate et cetra existing expansion joint fabric fascia fascia board file cabinet floor drain foundation fire extinguisher fire extinguisher cabinet federal fire hose fire hydrant fire hose cabinet figure finish finish floor finish grade finish wood fixture flashing flooring flush mount floor floor finish fluted concrete masonry unit face of concrete face of finish face of masonry face of slab foundation face of wall Fire Protection Contractor fire resistant fiber reinforced concrete fiber reinforced gypsum fiberglass reinforced plastic freezer feet, foot footing finned tubed radiation furring furniture fabric wall covering gauge gallon galvanized General Contrator glass-fiber-reinforced concrete glass-fiber-reinforeced gypsum glass-fiber-reinforeced plaster glass-fiber-reinforeced plastic glass block glue laminated wood government gypsum wallboard hazard hazardous materials handicap hose cabinet hollow core wood door hand dryer heavy duty hardboard high density overlay hardware hardwood hollow metal horizontal headquarters hour height heater highway heating, ventalation and air conditioning International Building Code inside diameter inside dimension inch/ inches install instrument insulation, (e), (ed) interior A LABEL A/E ADA ADD ADMIN AFF ALUM AMT APPROX APT ARCH ASI ASSN ASSY ASTM AVE AVG AWI B LABEL BD BFC BFF BITUM BLDG BLKHD BLVD BOCA BOT BRG BRG PL BSMT CAB CB CB CCTV CD CD CEM PLAS CEM PLAS CLG CIP CJ CJ CL CLG CLG HT CLO CLR CMU CNTR CNTRTP COL CONC CONC FLR CONF CONSTR COORD CORR CPT CSI CSMT CSWK CT CTB CTF CTR CU FT CU IN CUB CUST D LABEL DAT db DBL DBL ACT DR DBL GLZ DEG DEG C DEG F DEL DEMO DEPT DET DF DH DIA DIAG DIFF DIM DIR DISP DIV DJ DN DR DS DWG DWR E LABEL EA EC EFS EIFS EJ EL/ ELEV ELEC ELEV EMER ENAM ENCL ENTR EOS EPDM EQ EQUIP EQUIV ESCAL ESMT EST ECT EXIST EXP JT FAB FAS FAS BD FC FD FDTN FE FEC FED FH FH FHC FIG FIN FIN FLR FIN GR FIN WD FIXT FLASH FLG FLMT FLR FLR FIN FLUT CMU FOC FOF FOM FOS FOUND FOW FPC FR FRC FRG FRP FRZ FT FTG FTR FURG FURN FWC GA GAL GALV GC GFRC GFRG GFRP GFRP GL BLK GLU LAM GOVT GWB HAZ HAZ MAT HC HC HCWD HD HDBD HDO HDW HDWD HM HORIZ HQ HR HT HTR HWY HVAC IBC ID ID IN INSTL INSTR INSUL INT janitor janitor closet knock down kitchen knockout laminate laminated glass lacquer laundry lavatory laundry chute landing light emitting diode linear feet (foot) loose fill insulation left hand left hand reverse library locker room lane location large light light gauge louver door maintenance manual material maximum marker board Mechanical Contractor mail chute metal deck medium density overlay measure mechanical mechanical room medium melamine membrane mezzanine manufactured manufacturing manufacturer manufacturer's recommendation management minimum mirror miscellaneous metal lath molding (moulding) millwork masonry opening mount mounted mounting metal mullion not applicable National Building Code National Electric Code National Fire Code National Institute of Building Sciences not in contract number nominal not to scale out to out on center outside diameter outside dimension office overflow drain opening opposite overflow roof drain original Occupational Safety and Health Administration parging partial particleboard percent perforated package plastic laminate plywood panel porcelain pair prefabricated prefinish preformed preparation parking project paint post-tensioned concrete radius resilient base reflected ceiling plan roof drain reinforcing steel bars received receptacle reference refrigerator reinforced require required restroom request for information request for proposal right hand roof hatch right hand reverse room rough opening rating roof top unit JAN JAN CLO KD KIT KO LAM LAM GL LAQ LAU LAV LC LDG LED LF LF INS LH LHR LIB LKR RM LN LOC LRG LT LT GA LVDR MAINT MAN MATL MAX MB MC MCH MD MDO MEAS MECH MECH RM MED MEL MEMB MEZZ MFD MFG MFR MFR REC MGT MIN MIRR MISC ML MLDG MLWK MO MT MTD MTG MTL MULL NA NBC NEC NFC NIBS NIC NO NOM NTS O/O OC OD OD OFC OFD OPNG OPP ORD ORIG OSHA PARG PART PBD PCT PERF PKG PLAS LAM PLYWD PNL PORC PR PREFAB PREFIN PREFMD PREP PRKG PROJ PT PT CONC R RB RCP RD REBAR RECD RECPT REF REF REINF REQ REQD REST RFI RFP RH RH RHR RM RO RTG RTU SAT suspended acoustical tile SATC suspended acoustical tile ceiling SCD seat cover dispenser SCH school SCHED schedule SCHEM schematic SCWD solid core wood door SD smoke detector SD soap dispenser SECT section SF square foot (feet) SFTWD softwood SHR shower SHT sheet SIM similar SLNT sealant SM small SPEC specification SPKLR sprinkler SPKR speaker SQ square SQIN square inch SQ YD square yard SS stainless steel ST street STA station STD standard STL steel STL JST steel joist STL LNTL steel lintel STL PL steel plate STL RF DK steel roof deck STL TB steel tube STL TR steel truss STOR storage STR stair(s) STRUCT structural STRUCT STL structural steel SUPP supplement SURF surface SURR surround SURV survey SUSP suspend SUSP CLG suspended ceiling SV sheet vinyl SVC service SWR sewer SYS system T&G tongue and groove T/O top of TAN tangent TB tack board TB towel bar TC terra cotta TD towel dispenser TECH technical TEL telephone TEMP temperature TEMP temporary TEMP tempored glass TER terrazzo TFA to floor above TFB to floor below TFF top of finish floor THK thickness THRES threshold THRU through THRUOUT throughout TI tapered insulation TOS top of steel TOM top of masonry TPD toilet paper dispenser TR towel rack TRANS transom TRANS transparent TS tube steel TV television TYP typical UBC Uniform Building Code UFC Uniform Fire Code UL Underwriters Laboratories UMC Uniform Mechanical Code UNO unless noted otherwise UPC Uniform Plumbing Code UPS uninterruptible power supply UTIL utility VAR variation VAR varies VB vinyl base VCT vinyl composition tile VCT vitrified clay tile VEH vehicle VERT vertical VEST vestibule VIF verify in field VOL volume VP veneer plaster VR vapor retarder VTR vent through roof VWC vinyl wall covering VWF vinyl wall fabric W CAB wall cabinets W/ with W/O without WB wood base WC wall covering WD wood WH weep hole WHSE warehouse WO where occurs WP working point WSCT wainscot WT weight SINK LAVATORY TOILET SUPPLY AIR RETURN AIR EXIT LIGHT LIGHT FIXTURE IN CEILING GRID ROOF/OVERFLOW DRAIN FLOOR DRAIN URINAL Component Symbols DOUBLE SINGLE UTILITY COUNTERTOP WALL HUNG WALL HUNG FLOOR MOUNT 3 GANG 2 GANG CONCRETE MASONRY UNIT FACE BRICK EARTH CONCRETE PLYWOOD METAL/STEEL FINISHED WOOD TRIM WOOD BLOCKING WOOD SHIM INSULATION (LOOSE OR BATT.) INSULATION (RIGID) GYPSUM BOARD / PLASTER Material Symbols TITLE MARK SECTION MARK ELEVATION MARK CUT LINE DETAIL MARK PLAN NOTE DESIGNATION WHEELCHAIR CLEARANCE RADIUS WALL DESIGNATION DOOR NUMBER WINDOW NUMBER FURNITURE COLUMN DESIGNATION NORTH ARROW ROOM TAG UNIT MATCHLINE DEMOLITION NOTE DATUM POINT 1 View Name 1/8" = 1'-0" A DA 1t Door Label Door Number Hardware Set Frame Type 1t FM N Room name 101 Reference Symbols FB FB REVISION TAG UNIT A UNIT B # 1 A101 SIM A101 1 Ref 1 Ref 1 Ref 1 Ref SHEET REFERENCE DETAIL REFERENCE A101 1 SIM A1 # 101 45 min FG 168 HM23A=HM# 1. 2. 3. 4. 5. 6. 7. 8. All dimensions shown are to face of stud or masonry, unless noted otherwise. Dimensions designated as "CLR or "clear" indicate a clear dimension from face of finish to face of finish. Dimensions of exterior walls are to outside edge of foundation. Dimensions for all openings for Mechanical, Plumbing, Fire Protection and Electrical shall be fire stopped at each floor penetration. Provide bracing and blocking as required in walls supporting casework, tackboards, markerboards, and restroom accessories. All door frames are located 4" from adjacent wall, unless noted otherwise. All exposed outside corners of CMU shall be bullnosed. Seal all joints between dissimilar materials. All gypsum wallboard is 5/8" Type "X", unless noted otherwise. Base elevation is 0'-0" = XXX.X' (United States Geological Survey data). General Plan Notes 1. 2. 3. All ceilings are at 9'-0" AFF, unless noted otherwise. All bulkheads are at 8'-10" AFF, unless noted otherwise. All grids are centered in rooms, unless noted otherwise. General Refl. Ceiling Plan Notes REFLECTED CEILING PLAN LEGEND APC-1 2' X 2' Acoustical Panel Ceiling (09 51 13) APC-2 2' X 2' Washable Acoustical Panel Ceiling (09 51 13) APC-3 2' X 2' Humidity Resistant Acoustical Panel Ceiling with Aluminum Grid (09 51 13) APC-4 2' X 2' Humidity Resistant Acoustical Panel Ceiling (09 51 13) Walls to Deck Light Fixture (Reference E-Series Dwgs) Return Air (Reference M-Series Dwgs) Supply Air (Reference M-Series Dwgs) Exit Light (Reference E-Series Dwgs) Recessed Light Fixture Suspended Fixture in Areas with Exposed Ceilings (Reference E-Series Dwgs) S SOUND SYSTEM SPEAKER (REFERENCE E-SERIES/T- SERIES DWGS) 1. 2. 3. 4. Where utilized, tapered insulation shall be installed to achieve positive drainage with a minimum resultant slope of 1/4" per foot, unless noted otherwise. Low slope roof areas shall have a minimum of 4" rigid insulation over metal roof deck. Saddles, crickets, and slope portions of flat roof deck shall be formed by tapered insulation. Areas where tapered insulation is anticipated have been indicated, but shall not be considered all inclusive. It is Contractor's responsibility to provide sloped surfaces to achieve proper drainage. Roof penetrations and equipment shown shall not be considered all inclusive. Coordinate with Mechanical, Plumbing and Electrical Documents to confirm penetrations and equipment locations. Flash all roof penetrations in accordance with roofing manufacturer's recommendations. Provide crickets to allow for proper drainage around units. Roof walkway pads or blocks shall be installed in accordance with roofing manufacturer's recommendation where indicated and around entire perimeter of rooftop equipment. General Roof Plan Notes 0' - 6" MIN. 095113 - CEILING FINISH, REF ARCHITECTURAL CEILING PLANS 09 29 00 - INT GYB, 5/8" TYPE 'X' EACH SIDE 061000 - WOOD STUD FRAMING, 2X4 @ 16" O.C. 092900 - SOUND ATTENUATION BLANKET BRACE FRAMING TO DECK/STRUCTURE ABOVE AS REQUIRED BY S-SERIES DRAWINGS. 0' - 6" MIN. 095113 - CEILING FINISH, REF ARCHITECTURAL CEILING PLANS 092900 - INT GWB, 5/8" TYPE 'X' ON 2X4 WOOD FRAMING AT 16" O.C. 074113.13 - METAL LINER PANEL, PBR PRE-ENGINEERED STRUCTURE GIRT BATT INSULATION WITH VAPOR BARRIER PER PRE- ENGINEERED BUILDING MANUFACTURER. 074113.13 - METAL WAKK SIDING PANEL, AVP T.O. MASONRY 12'-0" AFF 095113 - CEILING FINISH, REF ARCHITECTURAL CEILING PLANS 042000 - CMU BOND BEAM, 10 IN 042000 - CMU, 10 IN 042000 - MASONRY JOINT REINFORCEMENT T.O. MASONRY 10'-0" AFF @ BUILDING A & C. 042000 - CMU BOND BEAM, 10 IN 042000 - CMU, 10 IN 042000 - MASONRY JOINT REINFORCEMENT 06 16 00.A1 - GYPSUM SHEATHING BOARD 061000 - WOOD STUD FRAMING, 2X4 @ 16" O.C. 072100 - 6" BLANKET INSULATION WITH VAPOR BARRIER 074200 - DIRECT-APPLIED EXTERIOR FINISH SYSTEM (DEFS) SEE WALL SECTION 2A/A-311 N 1 2 3 4 5 6 A B C D E 1 2 3 4 5 6 A B C D E Project No. Project Date Produced These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. KEY PLAN 6/13/2017 2:40:31 PM C:\_RevitLocal\2016-010.GTC_Bldg001_A_2016\2016-010.GTC_Bldg001_A_2016_tning.rvt 2016-010.GTC 06.12.2017 ARCHITECTURAL GENERAL NOTES AND ABBREVIATIONS A-001 Designer Author Greencastle Community School Corporation Greencastle Transportation Center 2016-010.GTC_Greencastle Community School Corporation_Greencastle Transportation Center_ 800 Tennessee Street Greencastle, IN 46135 A-001_ ARCHITECTURAL GENERAL NOTES AND ABBREVIATIONS 1 1/2" = 1'-0" 2A S4iC WALL TYPE 1 1/2" = 1'-0" 2B S4-C' WALL TYPE 1 1/2" = 1'-0" 3B SPF075-D WALL TYPE 1 1/2" = 1'-0" 3A M10-C WALL TYPE 1 1/2" = 1'-0" 4A M10-D WALL TYPE - NON-RATED # Revision Date

Transcript of Abbreviations General Roof Plan Notes General Plan...

Page 1: Abbreviations General Roof Plan Notes General Plan …keymarkcompany.com/sites/default/files/projects/5.4_architectural.pdf · glass block glue laminated wood government ... (moulding)

AbbreviationsClass A doorarchitect/engineerAmericans with Disabilities Actaddendumadministrationabove finished flooraluminumamountapproximateapartmentArchitectArchitect's Supplemental InstructionassociationassemblyAmerican Society for Testing and MaterialsavenueaverageArchitectural Woodworking institute

Class B doorboardbelow finished ceilingbelow finish floorbituminousbuildingbulkheadboulevardBuilding Officials and Code Administrators Association Internationalbottombearingbearing platebasement

cabinetchalk boardceramic baseclosed circuit televisionconstruction documentscontract documentscement plastercement plaster ceilingcast-in-placeconstruction jointcontrol jointcenter lineceilingceiling heightclosetclearconcrete masonry unitcountercountertopcolumnconcreteconcrete floorconferenceconstructioncoordinatecorridorcarpetConstruction Specifications Institutecasementcaseworkceramic tileceramic tile baseceramic tile floorcentercubic feetcubic inchcubiclecustodian

Class D doordatumdecibeldoubledouble acting doordouble glazedegreedegrees Celsiusdegrees Fahrenheitdeletedemolitiondepartmentdetaildrinking fountaindouble hung (door, window)diameterdiagonaldiffuserdimensiondirectiondispenserdivisiondouble joistdowndoordown spoutdrawingdrawer

Class E dooreachElectrical Contractorexterior finish systemexterior insulation and finish systemexpansion jointelevationelectricelevatoremergencyenamelenclosureentranceedge of slabethylene propylene diene monomerequalequipmentequivalentescalatoreasementestimateet cetraexistingexpansion joint

fabricfasciafascia boardfile cabinetfloor drainfoundationfire extinguisherfire extinguisher cabinetfederalfire hosefire hydrantfire hose cabinetfigurefinishfinish floorfinish gradefinish woodfixtureflashingflooringflush mountfloorfloor finishfluted concrete masonry unitface of concreteface of finishface of masonryface of slabfoundationface of wallFire Protection Contractorfire resistantfiber reinforced concretefiber reinforced gypsumfiberglass reinforced plasticfreezerfeet, footfootingfinned tubed radiationfurringfurniturefabric wall covering

gaugegallongalvanizedGeneral Contratorglass-fiber-reinforced concreteglass-fiber-reinforeced gypsumglass-fiber-reinforeced plasterglass-fiber-reinforeced plasticglass blockglue laminated woodgovernmentgypsum wallboard

hazardhazardous materialshandicaphose cabinethollow core wood doorhand dryerheavy duty hardboardhigh density overlayhardwarehardwoodhollow metalhorizontalheadquartershourheightheaterhighwayheating, ventalation and air conditioning

International Building Codeinside diameterinside dimensioninch/ inchesinstallinstrumentinsulation, (e), (ed)interior

A LABELA/EADAADDADMINAFFALUMAMTAPPROXAPTARCHASIASSNASSYASTMAVEAVGAWI

B LABELBDBFCBFFBITUMBLDGBLKHDBLVDBOCA

BOTBRGBRG PLBSMT

CABCBCBCCTVCDCDCEM PLASCEM PLAS CLGCIPCJCJCLCLGCLG HTCLOCLRCMUCNTRCNTRTPCOLCONCCONC FLRCONFCONSTRCOORDCORRCPTCSICSMTCSWKCTCTBCTFCTRCU FTCU INCUBCUST

D LABELDATdbDBLDBL ACT DRDBL GLZDEGDEG CDEG FDELDEMODEPTDETDFDHDIADIAGDIFFDIMDIRDISPDIVDJDNDRDSDWGDWR

E LABELEAECEFSEIFSEJEL/ ELEVELECELEVEMERENAMENCLENTREOSEPDMEQEQUIPEQUIVESCALESMTESTECTEXISTEXP JT

FABFASFAS BDFCFDFDTNFEFECFEDFHFHFHCFIGFINFIN FLRFIN GRFIN WDFIXTFLASHFLGFLMTFLRFLR FINFLUT CMUFOCFOFFOMFOSFOUNDFOWFPCFRFRCFRGFRPFRZFTFTGFTRFURGFURNFWC

GAGALGALVGCGFRCGFRGGFRPGFRPGL BLKGLU LAMGOVTGWB

HAZHAZ MATHCHCHCWDHDHDBDHDOHDWHDWDHMHORIZHQHRHTHTRHWYHVAC

IBCIDIDININSTLINSTRINSULINT

janitorjanitor closet

knock downkitchenknockout

laminatelaminated glasslacquerlaundrylavatorylaundry chutelandinglight emitting diodelinear feet (foot)loose fill insulationleft handleft hand reverselibrarylocker roomlanelocationlargelightlight gaugelouver door

maintenancemanualmaterialmaximummarker boardMechanical Contractormail chutemetal deckmedium density overlaymeasuremechanicalmechanical roommediummelaminemembranemezzaninemanufacturedmanufacturingmanufacturermanufacturer's recommendationmanagementminimummirrormiscellaneousmetal lathmolding (moulding)millworkmasonry openingmountmountedmountingmetalmullion

not applicableNational Building CodeNational Electric CodeNational Fire CodeNational Institute of Building Sciencesnot in contractnumbernominalnot to scale

out to outon centeroutside diameteroutside dimensionofficeoverflow drainopeningoppositeoverflow roof drainoriginalOccupational Safety and Health Administration

pargingpartialparticleboardpercentperforatedpackageplastic laminateplywoodpanelporcelainpairprefabricatedprefinishpreformedpreparationparkingprojectpaintpost-tensioned concrete

radiusresilient basereflected ceiling planroof drainreinforcing steel barsreceivedreceptaclereferencerefrigeratorreinforcedrequirerequiredrestroomrequest for informationrequest for proposalright handroof hatchright hand reverseroomrough openingratingroof top unit

JANJAN CLO

KDKITKO

LAMLAM GLLAQLAULAVLCLDGLEDLFLF INSLHLHRLIBLKR RMLNLOCLRGLTLT GALVDR

MAINTMANMATLMAXMBMCMCHMDMDOMEASMECHMECH RMMEDMELMEMBMEZZMFDMFGMFRMFR RECMGTMINMIRRMISCMLMLDGMLWKMOMTMTDMTGMTLMULL

NANBCNECNFCNIBSNICNONOMNTS

O/OOCODODOFCOFDOPNGOPPORDORIGOSHA

PARGPARTPBDPCTPERFPKGPLAS LAMPLYWDPNLPORCPRPREFABPREFINPREFMDPREPPRKGPROJPTPT CONC

RRBRCPRDREBARRECDRECPTREFREFREINFREQREQDRESTRFIRFPRHRHRHRRMRORTGRTU

SAT suspended acoustical tileSATC suspended acoustical tile ceilingSCD seat cover dispenserSCH schoolSCHED scheduleSCHEM schematicSCWD solid core wood doorSD smoke detectorSD soap dispenserSECT sectionSF square foot (feet)SFTWD softwoodSHR showerSHT sheetSIM similarSLNT sealantSM smallSPEC specificationSPKLR sprinklerSPKR speakerSQ squareSQIN square inchSQ YD square yardSS stainless steelST streetSTA stationSTD standardSTL steelSTL JST steel joistSTL LNTL steel lintelSTL PL steel plateSTL RF DK steel roof deckSTL TB steel tubeSTL TR steel trussSTOR storageSTR stair(s)STRUCT structuralSTRUCT STL structural steelSUPP supplementSURF surfaceSURR surroundSURV surveySUSP suspendSUSP CLG suspended ceilingSV sheet vinylSVC serviceSWR sewerSYS system

T&G tongue and grooveT/O top ofTAN tangentTB tack boardTB towel barTC terra cottaTD towel dispenserTECH technicalTEL telephoneTEMP temperatureTEMP temporaryTEMP tempored glassTER terrazzoTFA to floor aboveTFB to floor belowTFF top of finish floorTHK thicknessTHRES thresholdTHRU throughTHRUOUT throughoutTI tapered insulationTOS top of steelTOM top of masonryTPD toilet paper dispenserTR towel rackTRANS transomTRANS transparentTS tube steelTV televisionTYP typical

UBC Uniform Building CodeUFC Uniform Fire CodeUL Underwriters LaboratoriesUMC Uniform Mechanical CodeUNO unless noted otherwiseUPC Uniform Plumbing CodeUPS uninterruptible power supplyUTIL utilityVAR variationVAR variesVB vinyl baseVCT vinyl composition tileVCT vitrified clay tileVEH vehicleVERT verticalVEST vestibuleVIF verify in fieldVOL volumeVP veneer plasterVR vapor retarderVTR vent through roofVWC vinyl wall coveringVWF vinyl wall fabricW CAB wall cabinetsW/ withW/O withoutWB wood baseWC wall coveringWD woodWH weep holeWHSE warehouseWO where occursWP working pointWSCT wainscotWT weight

SINK

LAVATORY

TOILET

SUPPLY AIR

RETURN AIR

EXIT LIGHT

LIGHT FIXTURE IN

CEILING GRID

ROOF/OVERFLOW DRAIN

FLOOR DRAIN

URINAL

Component Symbols

DOUBLE SINGLE UTILITY

COUNTERTOP WALL HUNG

WALL HUNG FLOOR MOUNT

3 GANG2 GANG

CONCRETE MASONRY UNIT

FACE BRICK

EARTH

CONCRETE

PLYWOOD

METAL/STEEL

FINISHED WOOD TRIM

WOOD BLOCKING

WOOD SHIM

INSULATION (LOOSE OR BATT.)

INSULATION (RIGID)

GYPSUM BOARD / PLASTER

Material Symbols

TITLE MARK

SECTION MARK

ELEVATION MARK

CUT LINE

DETAIL MARK

PLAN NOTE DESIGNATION

WHEELCHAIR CLEARANCE RADIUS

WALL DESIGNATION

DOOR NUMBER

WINDOW NUMBER

FURNITURE

COLUMN DESIGNATION

NORTH ARROW

ROOM TAG

UNIT MATCHLINE

DEMOLITION NOTE

DATUM POINT

1View Name1/8" = 1'-0"

ADA

1t

Door Label

Door NumberHardware Set

Frame Type

1t

FM

N

Room name

101

Reference Symbols

FB

FB

REVISION TAG

UNIT A

UNIT B

#

1

A101

SIM

A101

1Ref

1 Ref

1 Ref

1RefSHEET REFERENCE

DETAIL REFERENCE

A1011

SIM

A1

#

101

45 m

in

FG

168

HM

23A

=H

M#

1.

2.

3.

4.

5.

6.

7.

8.

All dimensions shown are to face of stud or masonry, unless noted otherwise.Dimensions designated as "CLR or "clear" indicate a clear dimension from face offinish to face of finish. Dimensions of exterior walls are to outside edge of foundation.

Dimensions for all openings for Mechanical, Plumbing, Fire Protection and Electricalshall be fire stopped at each floor penetration.

Provide bracing and blocking as required in walls supporting casework, tackboards,markerboards, and restroom accessories.

All door frames are located 4" from adjacent wall, unless noted otherwise.

All exposed outside corners of CMU shall be bullnosed.

Seal all joints between dissimilar materials.

All gypsum wallboard is 5/8" Type "X", unless noted otherwise.

Base elevation is 0'-0" = XXX.X' (United States Geological Survey data).

General Plan Notes

1.

2.

3.

All ceilings are at 9'-0" AFF, unless noted otherwise.

All bulkheads are at 8'-10" AFF, unless noted otherwise.

All grids are centered in rooms, unless noted otherwise.

General Refl. Ceiling Plan Notes

REFLECTED CEILING PLANLEGEND

APC-1 2' X 2' AcousticalPanel Ceiling(09 51 13)

APC-22' X 2' WashableAcousticalPanel Ceiling(09 51 13)

APC-3

2' X 2' HumidityResistant AcousticalPanel Ceiling withAluminum Grid(09 51 13)

APC-42' X 2' HumidityResistant AcousticalPanel Ceiling(09 51 13)

Walls to Deck

Light Fixture(Reference E-Series Dwgs)

Return Air(Reference M-Series Dwgs)

Supply Air(Reference M-Series Dwgs)

Exit Light(Reference E-Series Dwgs)

Recessed Light FixtureSuspended Fixture in Areaswith Exposed Ceilings(Reference E-Series Dwgs)

SSOUND SYSTEM SPEAKER(REFERENCE E-SERIES/T-SERIES DWGS)

1.

2.

3.

4.

Where utilized, tapered insulation shall be installed to achieve positive drainage witha minimum resultant slope of 1/4" per foot, unless noted otherwise.

Low slope roof areas shall have a minimum of 4" rigid insulation over metal roofdeck. Saddles, crickets, and slope portions of flat roof deck shall be formed bytapered insulation. Areas where tapered insulation is anticipated have been indicated,but shall not be considered all inclusive. It is Contractor's responsibility to providesloped surfaces to achieve proper drainage.

Roof penetrations and equipment shown shall not be considered all inclusive.Coordinate with Mechanical, Plumbing and Electrical Documents to confirmpenetrations and equipment locations. Flash all roof penetrations in accordance withroofing manufacturer's recommendations. Provide crickets to allow for properdrainage around units.

Roof walkway pads or blocks shall be installed in accordance with roofingmanufacturer's recommendation where indicated and around entire perimeter ofrooftop equipment.

General Roof Plan Notes

0' -

6"

MIN

.

095113 - CEILING FINISH, REFARCHITECTURAL CEILINGPLANS

09 29 00 - INT GYB, 5/8" TYPE'X' EACH SIDE

061000 - WOOD STUD FRAMING,2X4 @ 16" O.C.

092900 - SOUND ATTENUATIONBLANKET

BRACE FRAMING TODECK/STRUCTURE ABOVE ASREQUIRED BY S-SERIES DRAWINGS.

0' -

6"

MIN

.

095113 - CEILING FINISH, REFARCHITECTURAL CEILING PLANS

092900 - INT GWB, 5/8" TYPE 'X' ON2X4 WOOD FRAMING AT 16" O.C.

074113.13 - METALLINER PANEL, PBR

PRE-ENGINEEREDSTRUCTURE GIRT

BATT INSULATION WITHVAPOR BARRIER PER PRE-ENGINEERED BUILDINGMANUFACTURER.

074113.13 - METALWAKK SIDINGPANEL, AVP

T.O. MASONRY

12'-0" AFF

095113 - CEILING FINISH, REFARCHITECTURAL CEILINGPLANS

042000 - CMU BOND BEAM,10 IN

042000 - CMU, 10 IN

042000 - MASONRY JOINTREINFORCEMENT

T.O. MASONRY

10'-0" AFF @ BUILDING A & C.

042000 - CMU BOND BEAM,10 IN

042000 - CMU, 10 IN

042000 - MASONRY JOINTREINFORCEMENT

06 16 00.A1 - GYPSUM SHEATHINGBOARD

061000 - WOOD STUD FRAMING,2X4 @ 16" O.C.

072100 - 6" BLANKET INSULATIONWITH VAPOR BARRIER

074200 - DIRECT-APPLIED EXTERIORFINISH SYSTEM (DEFS)

SEE WALL SECTION 2A/A-311

N

123456

A

B

C

D

E

123456

A

B

C

D

E

Project No.

Project Date

Produced

These Drawings and Specifications, and all copiesthereof are and shall remain the property and copyright ofthe Architect. They shall be used only with respect to this

Project and are not to be used on any other Project orWork without prior written permission from the Architect.

KEY PLAN

6/1

3/2

017 2

:40:3

1 P

M

C:\

_R

evitLocal\2016-0

10.G

TC

_B

ldg001_A

_201

6\2

016-0

10.G

TC

_B

ldg001_A

_2

016_tn

ing.r

vt

2016-010.GTC

06.12.2017

ARCHITECTURALGENERAL NOTES AND

ABBREVIATIONS

A-001

Designer Author

GreencastleCommunity School

Corporation

GreencastleTransportation

Center

2016-0

10.G

TC

_G

reencastle C

om

munity S

chool C

orp

ora

tion_G

reencastle T

ransport

ation C

ente

r_

800 Tennessee StreetGreencastle, IN 46135

A-0

01_ A

RC

HIT

EC

TU

RA

L G

EN

ER

AL N

OT

ES

AN

D A

BB

RE

VIA

TIO

NS

1 1/2" = 1'-0"2A

S4iC WALL TYPE

1 1/2" = 1'-0"2B

S4-C' WALL TYPE 1 1/2" = 1'-0"

3BSPF075-D WALL TYPE

1 1/2" = 1'-0"3A

M10-C WALL TYPE 1 1/2" = 1'-0"

4AM10-D WALL TYPE - NON-RATED

# Revision Date

Page 2: Abbreviations General Roof Plan Notes General Plan …keymarkcompany.com/sites/default/files/projects/5.4_architectural.pdf · glass block glue laminated wood government ... (moulding)

1

3

5

AF1A16D

AF1A15D

S4iC

S4iC

S4iC

S4iC'

S4-C'

S4iC

S4iC

S4iC

S4iC

S4iC

S4iC

S4-C'

S4iC

S4iC

S4-C'

S4iC

S4iC S4-C'

M10-C

M10-C

M10-D

M10-C

S4iC

17' -

4"

4' -

4 1

/4"

8' -

11 3

/4"

4' -

0"

15' - 0" 25' - 0" 6' - 0" 9' - 0" 21' - 0"

1' -

8"

7' -

2"

7' -

2"

1' -

4"

8' - 6" 6' - 0" 8' - 8" 16' - 10"

14' -

0"

5' -

6"

5' -

6"

7' -

2"

1' -

4"

23' - 4" 3' - 4" 14' - 0" 6' - 4" 8' - 0" 6' - 4"

4' -

4"

14' -

0"

1' -

2"

3' -

4"1

' - 1

0"

14' -

0"

13' -

4"

6' -

4"

4' -

8"

14' -

0"

1' -

2"

3' -

4"

1' -

6"

14' -

0"

12' -

0"

3' -

4"

7' -

2"

3' -

4"

6' -

10"

3' -

4"

5' -

4"

5' - 4" 3' - 4" 9' - 4" 3' - 4" 12' - 0" 3' - 4" 2' - 8" 3' - 4" 2' - 8" 3' - 4" 3' - 0" 3' - 4" 16' - 4" 3' - 4" 4' - 0" 3' - 4" 4' - 0" 3' - 4" 10' - 8"

M10-C

DRIVER RR

A105

DRIVER RR

A106

STAFF RR

A112

CUST

A111

HALL

A104

DRIVER'S LOUNGE

A103

PARTS STOR

A115

FLUID STOR

A116

HALL

A107

OFFICE/STOR

A102

OFFICE

A101

LOBBY

A100

MECH

A109OFFICE

A110

SERVICE BAY A

A117

SERVICE BAY C

A119

SERVICE/WASH BAY D

A120

SERVICE BAY B

A118

2E

A-301

4E

A-301

2D

A-301

4D

A-301

STOR

A110A

ELEC.

A108

S4iC

S4iC

A-5011A

A-5011B

A-5011C

A-5011D

A-5011E

A-5012E

A-5012D

A-5014D

A-5012B

6

12

1

1

1

1

1

1

1

222

2

3 3 3

A116AF 11

HM-001=

A118OH 1

A120OH 1

A119OH 1

A117OH 1

A103BF 6HM-002=F1

A10

0F

6

HM

-002

=F

1

A110AF 8HM-001=F1A110

NV 4HM-001=F1

A10

9F

9

HM

-001

=F

1

A10

8F

9

HM

-001

=F

1

A107AF 3HM-002=F1

A105F 7HM-001=F1

A106F 7HM-001=F1

A112F 7HM-001=F1

A111F 8HM-001=F1

A101F 4HM-001=F1

A10

3AF

3

HM

-001

=F

1

A10

2N

V

4H

M-0

01

=F

1

A10

7BF

3

HM

-002

=F

1

A11

5F

1

0H

M-0

03

=F

1

A11

6BF

1

0H

M-0

03

=F

1

11

11

11

11

AF1A15C

SPF075-D

SP

F075-D

SP

F075-D

A10

3CF

5

HM

-003

=F

1

A120AF 2HM-002=F1

A119AF 2HM-002=F1

TYP.

14

14

1414

S4-C

'

S4-C'S4-C'S4-C'S4-C'S4-C'S4-C'S

4-C

'S

4-C

'

100' - 0"

22' - 9" 27' - 3" 27' - 3" 22' - 9"

80' -

0"

5

6

2E

A-301

4E

A-301

2D

A-301

4D

A-301

A.F.F.ACP-1

9' - 0"

A.F.F.ACP-1

9' - 0"

A.F.F.ACP-1

9' - 0"

A.F.F.ACP-1

9' - 0"A.F.F.ACP-1

9' - 0"

A.F.F.ACP-1

9' - 0" A.F.F.ACP-1

9' - 0"

A.F.F.9' - 0"

A.F.F.9' - 0"

A.F.F.ACP-1

9' - 0"

A.F.F.9' - 0"

A.F.F.ACP-1

9' - 0"

A.F.F.ACP-1

9' - 0"

A.F.F.ACP-1

9' - 0"

10

A.F.F.11' - 6" A.F.F.11' - 5 3/8"

1 1

1

1

1

1

1

1

1

1

1

1111

3

4

4

4

7

78 888

9 999

10

10

10

1111

11

2E

A-301

7

6

3

1

4

2

5

87

6

1

3

4

2

5

786

1' - 5"1' - 10"

1' - 5"1' - 10"

3' - 4" 3' - 8"

6

2

3

1

4

5

7

8

1' - 5"2' - 0"

0' -

6"

0' -

2"

0' - 4 7/8"

09 22 16.C6 - INT STEEL STUDFRAMING, 3-5/8" @ 16" O.C.

09 29 00.B7 - INT GWB, 5/8" TYPE X

09 51 13.A2 - CEILING FINISH, REFARCHITECTURAL CEILING PLANS

2' - 6" 3' - 0"

CLEAR

+/- 3' - 4"

2' -

6"

1' -

8"

2' -

10"

OWNER-PROVIDEDREFRIGERATOR

24"D SINK BASECABINET

24"D BASECABINET

25"D PLASTIC LAMINATECOUNTER TOP

OWNER-PROVIDEDMICROWAVE

1' -

5"

2' -

9"

12"D WALL CABINET WITHMICROWAVE SHELF12"D WALL CABINET

C100 LOBBY WOC VWB PNT

ROOM # ROOM NAME FLOOR BASE NORTH

PNT

EAST

PNT

WEST

PNT

SOUTH CEILING

A100 APC-1

WALLS

C101 OFFICE VCT VWB PNT PNT PNT PNTA101 APC-1

C102 OFFICE/STOR VCT VWB PNT PNT PNT PNTA102 APC-1

C103 DRIVER'S LOUNGE VCT VWB PNT PNT PNT PNTA103 APC-1

C104 HALL VCT VWB PNT PNT PNT PNTA104 APC-1

C105 DRIVER'S RR RESIN VWB PNT PNT PNT PNTA105 GYP

C106 DRIVER'S RR RESIN VWB PNT PNT PNT PNTA106 GYP

C107 HALL VCT VWB PNT PNT PNT PNTA107 APC-1

C108 ELECTRICAL SC VWB PNT PNT PNT PNTA108 APC-1

C109 MECHANICAL SC VWB PNT PNT PNT PNTA109 EXPOSE

C110 OFFICE CPT VWB PNT PNT PNT PNTA110 APC-1

C110A STORAGE SC VWB PNT PNT PNT PNTA110A APC-1

C111 CUSTODIAL SC VWB PNT PNT PNT PNTA111 APC-1

C112 STAFF RR RESIN VWB PNT PNT PNT PNTA112 GYP

C115 PARTS STORAGE RESIN RESIN PNT PNT PNT PNTA115 GYP

C116 FLUID STORAGE RESIN RESIN PNT MTL PNT PNTA116 GYP

C117 SERVICE BAY A RESIN RESIN PNT - MTL -A117 EXPOSE

C118 SERVICE BAY B RESIN RESIN PNT MTL - -A118 EXPOSE

C119 SERVICE BAY C RESIN RESIN - - MTL MTLA119 EXPOSE

C120 SERVICE BAY D RESIN RESIN - MTL - MTLA120 EXPOSE

ROOM FINISH SCHEDULE

ABBREVIATIONS

ACP ACOUSTICAL PANEL CEILING (095113)CPT CARPET (096813)GYP GYPSUM BOARD CEILING (09290)MTL METAL LINER PANEL (074213)PNT PNT (099123 & 099600.99)RESIN RESINOUS FLOORING (096723)SC SEALED CONCRETEVCT VINYL COMPOSITE TILE (096519)VWB VINYL WALL BASE (096513)WOC WALK-OFF CARPET TILE (096813)

BUS WASH CURTAIN/DIVIDER:

Provide 68' long by 10' high retractable bus wash curtain/divider system asshown. Contractor shall verify final size and configuration with manufacturerand Owner. Verify all dimensions and construction conditions in the field.

18 oz. vinyl reinforced with a polyester mesh scrim

Clear 20 mil vinyl vision panel to allow a line of sight

Vinyl meets NFPA 701 & California State Fire Marshall standard

16 gauge galvanized steel track which resists rusting

Hemmed edges for a clean finish look

Resistant to all wash down chemicals

5 year warranty on curtain

Lifetime warranty on all hardware

Provide a bus wash curtain system by one of the following manufacturers oran equal product:

AKON Curtain and Divider - https://www.curtain-and-divider.com/wash-down-curtains/industrial-wash-bay-curtains/

AmCraft Manufacturing, Inc. -http://www.amcraftindustrialcurtainwall.com/car-wash-curtains/

QSD Inc. - http://www.qsd-inc.com/industrial-curtains/wash-bay-curtains/

N

123456

A

B

C

D

E

123456

A

B

C

D

E

Project No.

Project Date

Produced

These Drawings and Specifications, and all copiesthereof are and shall remain the property and copyright ofthe Architect. They shall be used only with respect to this

Project and are not to be used on any other Project orWork without prior written permission from the Architect.

KEY PLAN

6/1

3/2

017 2

:41:3

3 P

M

C:\

_R

evitLocal\2016-0

10.G

TC

_B

ldg001_A

_201

6\2

016-0

10.G

TC

_B

ldg001_A

_2

016_tn

ing.r

vt

2016-010.GTC

06.12.2017

FIRST FLOOR PLANS -TRANSPORTATION

BUILDING A

AF1A1

Designer Author

GreencastleCommunity School

Corporation

GreencastleTransportation

Center

2016-0

10.G

TC

_G

reencastle C

om

munity S

chool C

orp

ora

tion_G

reencastle T

ransport

ation C

ente

r_

800 Tennessee StreetGreencastle, IN 46135

AF

1A

1_ F

IRS

T F

LO

OR

PLA

NS

- T

RA

NS

PO

RT

AT

ION

BU

ILD

ING

A

1/8" = 1'-0"1A

FIRST TRANSPORTATION BLDG FLOOR PLAN

5.4.401 - RESTROOM ACCESSORY SCHEDULE

Type Mark Keynote Description Mounting Furnished By Installed By

1 10 28 00 GRAB BAR - 18" VERTICAL BOTTOM @ 40" AFF CONTRACTOR CONTRACTOR

2 10 28 00 GRAB BAR - 36" HORIZONTAL TOP @ 2'-11'' AFF CONTRACTOR CONTRACTOR

3 10 28 00 GRAB BAR - 42" HORIZONTAL TOP @ 2'-11'' AFF CONTRACTOR CONTRACTOR

4 10 28 00 TOILET TISSUE DISPENSER - DOUBLE BOTTOM @ 1'-6 AFF OWNER CONTRACTOR

5 08 31 13 ACCESS DOOR - 16" X 16" BOTTOM @ 40" AFF CONTRACTOR CONTRACTOR

6 10 28 00 PAPER TOWEL DISPENSER AND DISPOSAL DISPENSER OPENING @ 42" AFF OWNER CONTRACTOR

7 10 28 00 SOAP DISPENSER BOTTOM @ 4" ABOVE FIXTURE OWNER CONTRACTOR

8 10 28 13 MIRROR - 18" X 36" BOTTOM @ 4'' ABOVE FIXTURE CONTRACTOR CONTRACTOR

1/8" = 1'-0"4A

FIRST FLOOR RCP - TRANSPORTATION BLDG

PLAN NOTES

KEY NOTE

1 6” pipe bollard, reference detail 3B/A-501

2 077100 - Aluminum downspouts, 3”x4” with splash block.

3 077100 - Aluminum downspout (3"x4"), reference Roof Plan. Coordinate with C-Series forunderground installation and drain boot.

5 Spill containment platforms (by Owner).

6 Bus wash vinyl curtain system (see bus wash curtain note on sheet AF1A1).

11 083613 - Vehicle exhaust port

12 Exposed roof structure and deck.

14 Floor drain, see P-series drawings. Slope floor slab to drain. Typical

REFLECTED CEILING NOTES

KEY NOTE

1 095113 – Acoustical panel ceiling system, APC-1.

3 095113 – Acoustical panel ceiling hold-down clips.

4 Gypsum bulkhead, see detail 6C/AF1A1

5 Exposed structure. Prep all exposed structure, deck, piping, conduits and ductwork for finish.Reference I-series drawings for finish.

6 Suspended bus wash vinyl curtain system (see bus wash curtain note on sheet AF1A1).

7 077100 - Gutter, 5”x5”.

8 077100 - Downspout, 3”x4” with splash block.

9 077100 - Downspout (3"x4"), reference Roof Plan. Coordinate with C-Series for undergroundinstallation and drain boot.

10 083613 – Overhead coiling sectional service door. See Door Schedule.

11 Suspended gypsum ceiling

1/4" = 1'-0"6D

ENLARGED DRIVER'S REST ROOM PLANS - A105 & A106 1/4" = 1'-0"

5DENLARGED STAFF REST ROOM PLAN - A112

1 1/2" = 1'-0"6C

BULKHEAD DETAIL - TYPICAL 1/4" = 1'-0"

5CCASEWORK ELEVATION

# Revision Date

Page 3: Abbreviations General Roof Plan Notes General Plan …keymarkcompany.com/sites/default/files/projects/5.4_architectural.pdf · glass block glue laminated wood government ... (moulding)

55' - 0" 54' - 0" 56' - 0" 56' - 0" 54' - 0" 55' - 0"90' -

0"

330' - 0"

35' - 0" 40' - 0" 35' - 0" 35' - 0" 40' - 0" 35' - 0" 35' - 0" 40' - 0" 35' - 0"

BUS BAY 36

B136

BUS BAY 34

B134

BUS BAY 32

B132

BUS BAY 30

B130

BUS BAY 28

B128

BUS BAY 26

B126

BUS BAY 24

B124

BUS BAY 22

B122

BUS BAY 20

B120

BUS BAY 35

B135

BUS BAY 33

B133

BUS BAY 31

B131

BUS BAY 29

B129

BUS BAY 27

B127

BUS BAY 25

B125

BUS BAY 23

B123

BUS BAY 21

B121

BUS BAY 19

B119

1B

A-301

B11

8AF

1

2H

M-0

02

=F

1

B12

0AF

1

2H

M-0

02

=F

1

B12

0O

H

1

B12

2O

H

1

B12

4O

H

1

B12

6O

H

1

B12

8O

H

1

B13

0O

H

1

B13

2O

H

1

B13

4O

H

1

B13

6O

H

1B

135

OH

1

B13

3O

H

1

B13

1O

H

1

B13

1AF

1

2H

M-0

02

=F

1

B12

9AF

1

2H

M-0

02

=F

1

B12

9O

H

1

B12

7O

H

1

B12

5O

H

1

B12

3O

H

1

B12

1O

H

1

B11

9O

H

1

B11

9AF

1

2H

M-0

02

=F

1

B11

7AF

1

2H

M-0

02

=F

1

B11

9O

H

1

B12

1O

H

1

B12

3O

H

1

5' - 0" 14' - 0" 1' - 0" 14' - 0" 2' - 0" 14' - 0" 10' - 0" 14' - 0" 2' - 0" 14' - 0" 1' - 0" 14' - 0" 10' - 0" 14' - 0" 1' - 0" 14' - 0" 2' - 0" 14' - 0" 10' - 0"

1' - 0" 3' - 4"

1' - 4"

3' - 4" 1' - 0"1' - 0" 3' - 4"

1' - 4"

3' - 4" 1' - 0"

B13

2AF

1

2H

M-0

02

=F

1

B13

0AF

1

2H

M-0

02

=F

1

1' - 0" 3' - 4"1' - 4"

3' - 4" 1' - 0" 1' - 0" 3' - 4"

1' - 4"

3' - 4" 1' - 0"

3A

A-301

M10-D

M10-D

M10-D

3

3

3

3

3

3

3

3

3

3

ENTER, TYP.

EXIT, TYP.

1212 12

1' - 0"

1' - 0"1' - 0"1' - 0"

3' - 4"

1' - 4"

3' - 4"3' - 4"

1' - 4"

3' - 4"

BUS BAY 17

B117

BUS BAY 15

B115

BUS BAY 13

B113

BUS BAY 11

B111

BUS BAY 9

B109

BUS BAY 7

B107

BUS BAY 5

B105BUS BAY 3

B103

BUS BAY 1

B101

BUS BAY 18

B118

BUS BAY 16

B116

BUS BAY 14

B114

BUS BAY 12

B112

BUS BAY 10

B110

BUS BAY 8

B108

BUS BAY 6

B106

BUS BAY 4

B104

BUS BAY 2

B102

B10

5AF

1

2H

M-0

02

=F

1B

106A

F

12

HM

-002

=F

1

B10

7AF

1

2H

M-0

02

=F

1B

108A

F

12

HM

-002

=F

1

B11

7AF

1

2H

M-0

02

=F

1B

118A

F

12

HM

-002

=F

1

B12

0AF

1

2H

M-0

02

=F

1B

119A

F

12

HM

-002

=F

1

B11

7O

H

1

B11

5O

H

1

B11

3O

H

1

B11

1O

H

1

B10

9O

H

1

B10

7O

H

1

B10

5O

H

1

B10

3O

H

1

B10

1O

H

1B

102

OH

1

B10

4O

H

1

B10

6O

H

1

B10

8O

H

1

B11

0O

H

1

B11

2O

H

1

B11

4O

H

1

B11

6O

H

1

B11

8O

H

1

1A

A-301

1B

A-301

10' - 0" 14' - 0" 2' - 0" 14' - 0" 1' - 0" 14' - 0" 10' - 0" 14' - 0" 1' - 0" 14' - 0" 2' - 0" 14' - 0" 10' - 0" 14' - 0" 2' - 0" 14' - 0" 1' - 0" 14' - 0" 5' - 0"

1' - 0" 3' - 4"

1' - 4"

3' - 4" 1' - 0"1' - 0" 3' - 4"

1' - 4"

3' - 4" 1' - 0"

M10-D

M10-D

M10-D

A-5012A

A-5015A

33333

33333

ENTER, TYP.

EXIT, TYP.

1212 12

90' -

0"

04 20 00.B4 - CMU, 10 IN

04 20 00.B9 - CMU BOND BEAM

09 22 16.C8 - INT STEEL STUDFRAMING, 6" @ 16" O.C.

2 LAYERS OF 5/8" FIRE RATEDGYPSUM WALL BOARD ONBOTH SIDES.

SEAL PERIMETER OF WALLWITH FIRE RATED SEALANT

EXTEND BARRIER TO UNDERSIDEOF ROOF DECK/PANELS. SEALPERIMETER OF WALL WITH FIRERATED SEALANT

CUT AROUND ROOF PURLINSAND PROVIDE FIRE CAULK TOSEAL AROUND EACH PURLIN ASREQUIRED TO MAINTAIN 2-HOURFIRE BARRIER RATING.

N

123456

A

B

C

D

E

123456

A

B

C

D

E

Project No.

Project Date

Produced

These Drawings and Specifications, and all copiesthereof are and shall remain the property and copyright ofthe Architect. They shall be used only with respect to this

Project and are not to be used on any other Project orWork without prior written permission from the Architect.

KEY PLAN

6/1

3/2

017 2

:41:3

9 P

M

C:\

_R

evitLocal\2016-0

10.G

TC

_B

ldg001_A

_201

6\2

016-0

10.G

TC

_B

ldg001_A

_2

016_tn

ing.r

vt

2016-010.GTC

06.12.2017

FIRST FLOOR PLANS -BUS STORAGE BUILDING

B

AF1B1

Designer Author

GreencastleCommunity School

Corporation

GreencastleTransportation

Center

2016-0

10.G

TC

_G

reencastle C

om

munity S

chool C

orp

ora

tion_G

reencastle T

ransport

ation C

ente

r_

800 Tennessee StreetGreencastle, IN 46135

AF

1B

1_ F

IRS

T F

LO

OR

PLA

NS

- B

US

ST

OR

AG

E B

UIL

DIN

G B

1/32" = 1'-0"1E

KEY PLAN - BUS STORAGE BLDG

1/8" = 1'-0"3C

FIRST FLOOR PLAN - BUS STORAGE BLDG UNIT A

1/8" = 1'-0"1A

FIRST FLOOR PLAN - BUS STORAGE BLDG UNIT B

PLAN NOTES

KEY NOTE

1 6” pipe bollard, reference detail 3B/A-501

2 077100 - Aluminum downspouts, 3”x4” with splash block.

3 077100 - Aluminum downspout (3"x4"), reference Roof Plan. Coordinate with C-Series forunderground installation and drain boot.

5 Spill containment platforms (by Owner).

6 Bus wash vinyl curtain system (see bus wash curtain note on sheet AF1A1).

11 083613 - Vehicle exhaust port

12 Exposed roof structure and deck.

14 Floor drain, see P-series drawings. Slope floor slab to drain. Typical

# Revision Date

1/2" = 1'-0"5A

WALL SECTION - 2 HOUR FIRE RATED

Page 4: Abbreviations General Roof Plan Notes General Plan …keymarkcompany.com/sites/default/files/projects/5.4_architectural.pdf · glass block glue laminated wood government ... (moulding)

SLO

PE

1:1

2S

LO

PE

1:1

2

1

2

3

4

5

6

7

34' - 1 1/8" 30' - 0" 36' - 1 1/8"

1

2

3 33

44 4

6

SLO

PE

1:1

2

SLO

PE

1:1

2

SLO

PE

1:1

2

SLO

PE

1:1

2

48' - 1 1/8" 14' - 0" 96' - 0" 14' - 0" 96' - 0" 14' - 0" 48' - 1 1/8"

48' - 1 1/8" 14' - 0" 96' - 0" 14' - 0" 96' - 0" 14' - 0" 48' - 1 1/8"

1

4

5

6

71

1

2

2

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

5

5

5

5

5

N

123456

A

B

C

D

E

123456

A

B

C

D

E

Project No.

Project Date

Produced

These Drawings and Specifications, and all copiesthereof are and shall remain the property and copyright ofthe Architect. They shall be used only with respect to this

Project and are not to be used on any other Project orWork without prior written permission from the Architect.

KEY PLAN

6/1

3/2

017 2

:41:4

3 P

M

C:\

_R

evitLocal\2016-0

10.G

TC

_B

ldg001_A

_201

6\2

016-0

10.G

TC

_B

ldg001_A

_2

016_tn

ing.r

vt

2016-010.GTC

06.12.2017

ROOF PLAN & ROOFDETAILS - BUILDINGS A &

B

AR100

Designer Author

GreencastleCommunity School

Corporation

GreencastleTransportation

Center

2016-0

10.G

TC

_G

reencastle C

om

munity S

chool C

orp

ora

tion_G

reencastle T

ransport

ation C

ente

r_

800 Tennessee StreetGreencastle, IN 46135

AR

100_ R

OO

F P

LA

N &

RO

OF

DE

TA

ILS

- B

UIL

DIN

GS

A &

B

3/32" = 1'-0"1C

ROOF PLAN - TRANSPORTATION BLDG

ROOF PLAN NOTES

KEY NOTE

1 074113.16 - Metal standing seam roof system

2 077100 – Metal Gutter, 5”x5”.

3 077100 – Metal downspout, 3”x4” with splash block.

4 077100 - Metal downspout (3”x4”), reference Roof Plan. Coordinate with C-Series forunderground installation and drain boot.

5 074113.16 – Snow and ice Guard, bar type.

6 Not Used

7 Not Used

3/32" = 1'-0"1A

ROOF PLAN - BUS STORAGE BLDG

# Revision Date

Page 5: Abbreviations General Roof Plan Notes General Plan …keymarkcompany.com/sites/default/files/projects/5.4_architectural.pdf · glass block glue laminated wood government ... (moulding)

1

2

3

4 6

7

8

2D

A-301

4D

A-301

9

1

4

BEYOND

44 66

7

8

7

8

3

SPECSECTION

EXTERIOR FINISH SCHEDULE

MAT'L COLOR: BASIS OF DESIGN

THIS LEGEND IS PROVIDED FOR REFERENCE PURPOSES ONLY. PRODUCTS/COLORSINDICATED ARE BASED ON BASIS-OF-DESIGN MANUFACTURERS. REFER TOSPECIFICATIONS FOR LIST OF ACCEPTED EQUAL MANUFACTURERS/PRODUCTS.

079200 SEALANTS ALL SEALANTS USED IN MASONRY CONTROL JOINTSSHALL MATCH THE MASONRY MORTAR.

ALL SEALANTS USED IN EXPOSED CONCRETE SHALLMATCH THE SURROUNDING COLOR CONCRETE,UNLESS NOTED OTHERWISE.

ALL SEALANTS USED TO SEAL AROUND EXTERIORWINDOWS AND DOOR FRAMES SHALL MATCH THEWINDOW AND DOOR FRAME FINISH COLOR.

ALL SEALANTS USED TO SEAL THE EXTERIOR METALWALL/ROOF PANEL SHALL MATCH THE WALL/ROOFPANEL FINISH COLOR.

083323 OVERHEADCOILING DOORS

COLOR TO MATCH MBCI Signature 300 'Almond'

099600.99 HIGHPERFORMANCECOATING

HOLLOW METAL DOOR, DOOR FRAME AND WINDOWFRAME: MATCH MBCI Signature 300 'Almond'

CMU: Match MBCI Signature 300 'Almond'

PIPE BOLLARD: COLOR TO MATCH "SAFETY YELLOW"

042000 BRICK BRICK TYPE A: Basis of design - Belden 'Landmark GrayVelour'.

072400 DEFS/STUCCO COLOR TO MATCH STO 32136 'Sandlewood'.

074113.16 STANDING-SEAMMETAL ROOF

COLOR TO MATCH MBCI Signature 300 'Medium Bronze'

074213 METAL WALL LINERPANEL

COLOR TO MATCH MBCI Signature 300 'Almond'

077100 ALUM GUTTERALUM DOWNSPOUT

COLOR TO MATCH MBCI Signature 300 'Medium Bronze'

083613 SECTIONALDOORS

COLOR TO MATCH MBCI Signature 300 'Almond'

085113 ALUM WINDOWS COLOR TO MATCH MBCI Signature 300 'Almond'FIRST FLOOR0' - 0"

2E

A-301

4E

A-301

121

121

5

9

10

3

4

1

6

10

13

99

2D

A-301

4D

A-301

5

9

3

1

6

5

BEYOND

9

BEYOND

5 5

6 6

3

FIRST FLOOR0' - 0"

2E

A-301

4E

A-301

121

121

5

9

10

3

4

1

6

10

3 1

99

121

121

5

31

6

1

5

3

5

10

2

1

6

1010

555555555

66

101010101010

2

11

2

101010101010101010

66

5

10

2

1

6

10 10

6

5 5 5 5

6

5 5 5 5 5

6 6

10 10 10 10 10 10 10 10 10 10 10 10 10 10 10

2

1

2

1

121

121

5

1

6

13

5

3

N

123456

A

B

C

D

E

123456

A

B

C

D

E

Project No.

Project Date

Produced

These Drawings and Specifications, and all copiesthereof are and shall remain the property and copyright ofthe Architect. They shall be used only with respect to this

Project and are not to be used on any other Project orWork without prior written permission from the Architect.

KEY PLAN

6/1

3/2

017 2

:41:0

0 P

M

C:\

_R

evitLocal\2016-0

10.G

TC

_B

ldg001_A

_201

6\2

016-0

10.G

TC

_B

ldg001_A

_2

016_tn

ing.r

vt

2016-010.GTC

06.12.2017

EXTERIOR BUILDINGELEVATIONS - BUILDING A

& B

A-201

Designer Author

GreencastleCommunity School

Corporation

GreencastleTransportation

Center

2016-0

10.G

TC

_G

reencastle C

om

munity S

chool C

orp

ora

tion_G

reencastle T

ransport

ation C

ente

r_

800 Tennessee StreetGreencastle, IN 46135

A-2

01_ E

XT

ER

IOR

BU

ILD

ING

ELE

VA

TIO

NS

- B

UIL

DIN

G A

& B

1/8" = 1'-0"4E

NORTH ELEVATION - TRANSPORTATION BLDG

EXTERIOR ELEVATION NOTES

KEY NOTE

1 074113.16 - STANDING -SEAM METAL ROOF SYSTEM

2 074113.16 - SNOW GUARD/SNOW DAM, BAR TYPE.

3 077100 - ALUMINUM GUTTER, 5"X5".

4 077100 - ALUMINUM DOWNSPOUT, 3"X4" WITH SPLASH BLOCK.

5 077100 - ALUMINUM DOWNSPOUT, 3"X4" TO DRAIN BOOT. COORDINATE WITHC-SERIES DRAWINGS.

6 METAL VERTICAL WALL SIDING (AVP).

7 METAL DRIP TRIM/WINDOW SILL

8 042000 - BRICK VENEER WATER TABLE

9 PIPE BOLLARD. SEE DETAIL 3B/A-501.

10 083613 - SECTIONAL OVERHEAD SERVICE DOOR. SEE DOOR & FRAME SCHEDULE.

1/8" = 1'-0"2E

EAST ELEVATION - TRANSPORTATION BLDG

1/8" = 1'-0"4D

SOUTH ELEVATION - TRANSPORTATION BLDG 1/8" = 1'-0"2D

WEST ELEVATION - TRANSPORTATION BLDG

3/32" = 1'-0"1B

EAST ELEVATION - BUS STORAGE BLDG

3/32" = 1'-0"1C

NORTH ELEVATION - BUS STORAGE BLDG

3/32" = 1'-0"1A

SOUTH ELEVATION - BUS STORAGE BLDG

3/32" = 1'-0"4B

WEST ELEVATION - BUS STORAGE BLDG

# Revision Date

Page 6: Abbreviations General Roof Plan Notes General Plan …keymarkcompany.com/sites/default/files/projects/5.4_architectural.pdf · glass block glue laminated wood government ... (moulding)

2E

A-3014E

A-301

12

112

1

J K L2E

A-301

4E

A-301

A-3113A

A-3111A

A-3112A

12

1

12

1

1169 SF

SERVICE BAY C

A119

1135 SF

SERVICE BAY A

A117

650 SF

DRIVER'S LOUNGE

A103

313 SF

LOBBY

A100

2D

A-301

4D

A-301

A-3114A

A-3115A

11 1312 14 15

2D

A-301

4D

A-301

A-3116A

A-3121A

121

121

A-3123A

A-3124A

FOUNDATION PLAN -BUILDING B

0' - 0"

ROOF FRAMING PLAN -BUILDING B

14' - 4 1/4"

ROOF FRAMING PLAN -BUILDING A

18' - 4 1/4"

CA B D E

A-3122A

1211

12

N

123456

A

B

C

D

E

123456

A

B

C

D

E

Project No.

Project Date

Produced

These Drawings and Specifications, and all copiesthereof are and shall remain the property and copyright ofthe Architect. They shall be used only with respect to this

Project and are not to be used on any other Project orWork without prior written permission from the Architect.

KEY PLAN

6/1

3/2

017 2

:41:0

5 P

M

C:\

_R

evitLocal\2016-0

10.G

TC

_B

ldg001_A

_201

6\2

016-0

10.G

TC

_B

ldg001_A

_2

016_tn

ing.r

vt

2016-010.GTC

06.12.2017

BUILDING SECTIONS -BUILDING A & B

A-301

Designer Author

GreencastleCommunity School

Corporation

GreencastleTransportation

Center

2016-0

10.G

TC

_G

reencastle C

om

munity S

chool C

orp

ora

tion_G

reencastle T

ransport

ation C

ente

r_

800 Tennessee StreetGreencastle, IN 46135

A-3

01_ B

UIL

DIN

G S

EC

TIO

NS

- B

UIL

DIN

G A

& B

1/8" = 1'-0"2D

BUILDING SECTION - TRANSPORTATION BLDG A 1/8" = 1'-0"

4DBUILDING SECTION - TRANSPORTATION BLDG A

1/8" = 1'-0"2E

BUILDING SECTION - TRANSPORTATION BLDG A 1/8" = 1'-0"

4EBUILDING SECTION - TRANSPORTATION BLDG A

3/32" = 1'-0"1A

BUILDING SECTION - BUS STORAGE BLDG B

3/32" = 1'-0"1B

BUILDING SECTION - BUS STORAGE BLDG B

3/32" = 1'-0"3A

BUILDING SECTION - BUS STORAGE BLDG B

# Revision Date

Page 7: Abbreviations General Roof Plan Notes General Plan …keymarkcompany.com/sites/default/files/projects/5.4_architectural.pdf · glass block glue laminated wood government ... (moulding)

A-3112D

A-3111E

PREFINISHED METAL LINERPANEL SYSTEM. PBR PANEL.TYPICAL

033000 - CAST-IN-PLACECONCRETE SLAB, SEE S-SERIESDWGS.

TOP OFICF6 WALL18'-0" AFF

PREFINISHED METAL WALL PANELSYSTEM. AVP PANEL. TYPICAL

PRE-ENGINEERED BUILDINGSTRUCTURAL GIRT. TYPICAL

BATT INSULATION PER PRE-ENGINEERED BUILDINGMANUFACTURER

07 21 00.B2 - PERIMETER/UNDERSLABINSULATION, 2" THK, 24" HORIZ. MIN.

A-3116E

10' -

0"

10' -

8"

VIF

M10-D

09 51 13.B2 - ACOUSTICAL PANELCEILING, APC-1

03 30 00.A5 - ISOLATION JOINT, REFS-SERIES DWGS

03 30 00 - CONC SLAB,REF S-SERIES DWGS

04 20 00.B4 - CMU, 10 IN

3/4" PLYWOOD SHEATHING,PRIMED AND PAINTED

BATT INSULATIONWITH VAPOR BARRIER

2X6 WOOD STUDFRAMING AT 16" O.C.BRANCE WALL ASREQUIRED.

A-3114D

A-3114E

TOP OFICF6 WALL18'-0" AFF

A-3111E

Sim

A-3113D

07 21 00.B2 - PERIMETER/UNDERSLABINSULATION, 2" THK, 24" HORIZ. MIN.

A-3111C

SUSPENDED GYPSUM SHEATHINGCEILING, 5/8" WITH 6" METAL STUDFRAMING AT 24" O.C.. REF RCP.

07 21 00.B2 - PERIMETER/UNDERSLABINSULATION, 2" THK, 24" HORIZ. MIN.

TOP OFICF6 WALL18'-0" AFF

A-3111C

Sim

A-3114E

Sim

A-3114D

Sim

07 21 00.B2 - PERIMETER/UNDERSLABINSULATION, 2" THK, 24" HORIZ. MIN.

A-3116D

TOP OFICF6 WALL18'-0" AFF

A-3111C

Sim

07 21 00.B2 - PERIMETER/UNDERSLABINSULATION, 2" THK, 24" HORIZ. MIN.

METAL LINER PANEL, PBR PANEL

STANDING SEAM METAL ROOFINGPANEL, DOUBLE-LOCK DLK.

METAL GUTTER ANDDOWNSPOUT SYSTEM PERPER-ENGINEERED BUILDINGMANUFACTURER.

BLANKET INSULATION WITHHEAVY DUTY VAPORBARRIER/LINER.

STEEL ROOF PURLIN PERPRE-ENGINEERED BUILDINGMANUFACTURER.

METAL WALL PANEL,AVP PANEL

STEEL STRUCTURAL GIRT PERPRE-ENGINEERED BUILDINGMANUFACTURER

12

1

03 30 00 - CONCRETE FOUNDATION,SEE S-SERIES DWGS.

03 30 00.A3 - CONC SLAB, REFS-SERIES DWGS

BLANKET INSULATION WITHHEAVY DUTY VAPORBARRIER/LINER

STEEL STRUCTURAL GIRT PERPRE-ENGINEERED BUILDINGMANUFACTURER

METAL LINER PANEL,PBR PANEL.

METAL PANEL, AVP PANEL.TYPICAL

07 21 00.B2 - PERIMETER/UNDERSLABINSULATION, 2" THK, 24" HORIZ. MIN.

03 30 00 - SERVICE BAY CONCRETESLAB, REF S-SERIES DWGS.

M10-D

096723 - RESINOUS FLOORING,SEE I-SERIES DWGS.

03 30 00 - CONCRETE GRADEBEAM, SEE S-SERIES DWGS.

09 65 13.B1 - RESILIENT WALL BASE

03 30 00.A5 - ISOLATION JOINT, REFS-SERIES DWGS

03 30 00.A3 - CONC SLAB, REFS-SERIES DWGS

TOP OFICF6 WALL18'-0" AFF

BLANKET INSULATION WITH HEAVYDUTY VAPOR BARRIER/LINER.

STANDING SEAM METALROOFING PANEL, DOUBLE-LOCK DLK.

STEEL STRUCTURAL GIRT PERPRE-ENGINEERED BUILDINGMANUFACTURER.

METAL STANDING SEAM METALROOF EDGE TRIM/FASCIA.

METAL WALL PANEL, AVP PANELPRE-FINISHED METALCOVER. FINISH TOMATCH AVP WALLPANELS.

083613 - OVERHEADSECTIONAL DOOR, ELECTRICWITH REMOTE.

STEEL HEADER PER PRE-ENGINEERED BUILDINGMANUFACTURER.

METAL WALL PANELS, AVPPANEL. TYPICAL

BATT INSULATION WITH VAPORBARRIER PER PRE-ENGINEERED BUILDINGMANUFACTURER.

METAL LINER PANEL,PBR PANEL. TYPICAL

079200 - JOINT SEALANT,CONTINUOUS ENTIRE FRAME.

079200 JOINT SEALANT,CONTINUOUS ENTIREPERIMETER.

PREFINISHED METAL WALLPANEL, AVP PANEL. TYPICAL

WALL PANEL WINDOW HEADTRIM PER PRE-ENGINEEREDMETAL BUILDINGMANUFACTURER

S4-C'

BATT INSULATION WITH VAPORBARRIER PER PRE-ENGINEEREDBUILDING MANUFACTURER

085113 - ALUMINUMWINDOW SYSTEM

WOOD WINDOW STOOL, PAINTED.

WOOD STOOL APRON, PAINTED.

2X4 WOOD STUD FRAMINGAT 16' O.C.

AIR BARRIER

04 20 00 - FACE BRICK

07 20 00 - AIR SPACE09 29 00.B7 - INT GWB, 5/8" TYPE X

STEEL STRUCTURAL GIRT PERPRE-ENGINEERED BUILDINGMANUFACTURER

BLANKET INSULATION WITHHEAVY DUTY VAPORBARRIER

06 16 00.D12 - WOOD PANELSHEATHING, 1/2"

085113 - ALUMINUMWINDOW SYSTEM.

METAL WINDOWSILL/FLASHING,CONTINUOUS.

09 65 13.B1 - RESILIENT WALL BASE

09 29 00.B7 - INT GWB, 5/8" TYPE X

METAL BASE ANGLE PER PRE-ENGINEERED BLDG MANUFACTURER

2X4 WOOD STUD FRAMINGAT 16" O.C.

BLANKET INSULATION WITHVAPOR BARRIER

STEEL GIRT PER PRE-ENGINEEREDBLDG MANUFACTURER

04 20 00.O6 - BRICK VENT @ 24" O.C.

04 20 00.O1 - FLASHING, EMBEDDEDTHROUGH-WALL W/ WEEPS

04 20 00.N2 - CAVITY DRAINAGEMATERIAL

04 20 00.O5 - STAINLESS STEELTERMINATION BAR

04 20 00.F1 - FACE BRICK

06 16 00.D12 - WOOD PANELSHEATHING, 1/2"

AIR BARRIER

03 30 00 - CONCRETEFOUNDATION. SEE S-SERIESDWGS.

07 21 00.B2 - PERIMETER/UNDERSLABINSULATION, 2" THK, 24" HORIZ. MIN.

N

123456

A

B

C

D

E

123456

A

B

C

D

E

Project No.

Project Date

Produced

These Drawings and Specifications, and all copiesthereof are and shall remain the property and copyright ofthe Architect. They shall be used only with respect to this

Project and are not to be used on any other Project orWork without prior written permission from the Architect.

KEY PLAN

6/1

3/2

017 2

:41:1

2 P

M

C:\

_R

evitLocal\2016-0

10.G

TC

_B

ldg001_A

_201

6\2

016-0

10.G

TC

_B

ldg001_A

_2

016_tn

ing.r

vt

2016-010.GTC

06.12.2017

WALL SECTIONS -BUILDING A

A-311

Designer Author

GreencastleCommunity School

Corporation

GreencastleTransportation

Center

2016-0

10.G

TC

_G

reencastle C

om

munity S

chool C

orp

ora

tion_G

reencastle T

ransport

ation C

ente

r_

800 Tennessee StreetGreencastle, IN 46135

A-3

11_ W

ALL S

EC

TIO

NS

- B

UIL

DIN

G A

1/2" = 1'-0"1A

WALL SECTION @ SERVICE BAYS 1/2" = 1'-0"

2AWALL SECTION - BETWEEN LOUNGE & OFFICE

1/2" = 1'-0"3A

WALL SECTION @ OFFICE 1/2" = 1'-0"

4AWALL SECTION @ GABLE END SERVICE BAY

1/2" = 1'-0"5A

WALL SECTION @ GABLE END LOUNGE 1/2" = 1'-0"

6AWALL SECTION @ SERVICE DOOR

1" = 1'-0"1E

GUTTER DETAIL

1" = 1'-0"2D

FOUNDATION DETAIL - TYPICAL

1" = 1'-0"6E

WALL DETAIL

1" = 1'-0"1C

EAVE DETAIL

1" = 1'-0"6D

SECTIONAL DOOR HEAD DETAIL

1" = 1'-0"4E

WINDOW HEAD DETAIL, TYPICAL

1" = 1'-0"4D

WINDOW SILL DETAIL, TYPICAL.

# Revision Date

1" = 1'-0"3D

Detail 18

Page 8: Abbreviations General Roof Plan Notes General Plan …keymarkcompany.com/sites/default/files/projects/5.4_architectural.pdf · glass block glue laminated wood government ... (moulding)

TOP OF ICF614'-0" AFF

A-3111E

Sim

A-3116D

Sim

SITE PAVING, SEEC-SERIES DWGS

03 30 00 - CONCRETEFOUNDATION. SEE S-SERIES DWGS.

03 30 00 - CONC. FLOORSLAB. SEE S-SERIESDWGS.

TOP OF ICF614'-0" AFF

FINISH FLOOR0'-0" AFF

A-3111E

Sim

A-3112D

Sim

FINISH GRADE, SEEC-SERIES DWGS

03 30 00 - CONCRETEFOUNDATION. SEE S-SERIES DWGS.

03 30 00 - CONC. FLOORSLAB. SEE S-SERIES DWGS.

FINISH FLOOR0'-0" AFF

A-3112D

Sim

A-3111C

Sim

03 30 00 - CONC. FOUNDATION.SEE S-SERIES DWGS.

03 30 00 - CONC.FLOOR SLAB. SEE S-SERIES DWGS.

A-3124D

03 30 00 - CONC. FLOOR SLAB.SEE S-SERIES DWGS.

03 30 00 - CONC. FOUNDATION.SEE S-SERIES DWGS.

04 20 00.B4 - CMU, 10 IN

09 29 00 - 2 LAYERS OF5/8" FIRE RATED GWB ONBOTH SIDES

SEAL JOINT WITH FIRERATED SEALANT TOCONTINUE RATING

04 20 00.B9 - CMU BOND BEAM

09 22 16.C8 - INT STEEL STUDFRAMING, 6" @ 16" O.C.

2' -

8"

03 30 00 - CONC.FLOOR SLAB.SEE S-SERIES DWGS.

N

123456

A

B

C

D

E

123456

A

B

C

D

E

Project No.

Project Date

Produced

These Drawings and Specifications, and all copiesthereof are and shall remain the property and copyright ofthe Architect. They shall be used only with respect to this

Project and are not to be used on any other Project orWork without prior written permission from the Architect.

KEY PLAN

6/1

3/2

017 2

:41:1

6 P

M

C:\

_R

evitLocal\2016-0

10.G

TC

_B

ldg001_A

_201

6\2

016-0

10.G

TC

_B

ldg001_A

_2

016_tn

ing.r

vt

2016-010.GTC

06.12.2017

WALL SECTIONS -BUILDING A & B

A-312

Designer Author

GreencastleCommunity School

Corporation

GreencastleTransportation

Center

2016-0

10.G

TC

_G

reencastle C

om

munity S

chool C

orp

ora

tion_G

reencastle T

ransport

ation C

ente

r_

800 Tennessee StreetGreencastle, IN 46135

A-3

12_ W

ALL S

EC

TIO

NS

- B

UIL

DIN

G A

& B

1/2" = 1'-0"1A

WALL SECTION @ BUILDING B 1/2" = 1'-0"

2AWALL SECTION @ BUILDING B

1/2" = 1'-0"3A

WALL SECTION @ BUILDING B 1/2" = 1'-0"

4ARATED WALL SECTION @ BUILDING B

# Revision Date

1" = 1'-0"4D

2-HOUR BARRIER WALL DETAL

Page 9: Abbreviations General Roof Plan Notes General Plan …keymarkcompany.com/sites/default/files/projects/5.4_architectural.pdf · glass block glue laminated wood government ... (moulding)

STEEL PER-ENGINEEREDBUILDING STRUCTURE

STRUCTURAL GIRT

METAL WALL PANELS,AVP PANEL. TYPICAL

METAL LINER PANEL,PBR PANEL. TYPICAL

BATT INSULATION PER PRE-ENGINEERED BUILDINGMANUFACTURER

METAL DOWNSPOUT

6" PIPE BOLLARD,REFERENCE C-SERIES DWGS.

PRE-FINISHED METAL COVER,FINISH TO MATCH METAL EXTERIORPANELS.

083613 - OVERHEADSECTIONAL DOOR, ELECTRICWITH REMOTE.

SECTIONAL DOOR FRAMING.STRUCTURAL GIRT

METAL WALL PANEL,AVP PANEL. TYPICAL

BATT INSULATION PERPER-ENGINEEREDBUILDING MANUFACTURER

METAL LINER PANEL,PBR PANEL. TYPICAL

M10-D

STRUCTURAL GIRT

METAL WALL PANELS,AVP PANEL. TYPICAL

BATT INSULATION PER PER-ENGINEERED BUILDINGMANUFACTURERMETAL LINER PANEL,

PBR PANEL. TYPICAL

07 92 00.B1 - JOINT SEALANT W/BACKER ROD

M10-C

STRUCTURAL GIRT PERPER-ENGINEERED BUILDINGMANUFACTURER

METAL WALL PANELS,AVP PANEL. TYPICAL

METAL LINER PANEL,PBR PANEL. TYPICAL

07 92 00.B1 - JOINT SEALANT W/BACKER ROD

S4-C

'

BATT INSULATION PER PRE-ENGINEERED BUILDINGMANUFACTURER

PROVIDE ADDITIONALINSULATION/BLOCKING TOCLOSE AIR PATH FROM SERVICEBAY/FLUIDS ROOM INTO THEOFFICE SIDE OF THE BUILDING.

STRUCTURAL GIRT

2X4 WOOD STUD FRAMINGAT 16" O.C.

METAL DOWNSPOUT

3' -

2"

09 29 00.B7 - INT GWB, 5/8" TYPE X

METAL FLASHING/BRICK CAP BELOW

METAL WALL PANELS, AVP PANEL.TYPICAL

STEEL PRE-ENGINEEREDBUILDING STRUCTURE

BATT INSULATION PER PRE-ENGINEERED BUILDINGMANUFACTURER

0' - 10"

S4iC

07 92 00.B1 - JOINT SEALANT W/BACKER ROD

085113 - ALUM WINDOW,SLIDING.

METAL FLASHING/BRICK CAP BELOW

METAL WALL PANELS, AVP PANEL. TYPICAL

S4-C'

METAL WINDOWSTOOL/BRICK CAP, BELOW

WOOD WINDOW STOOL,BELOW

M10-C

S4-C'

S4iC

081113 - HOLLOW METAL FRAME ANDDOOR, SEE DOOR OPENING SCHEDULE.

M10-C

M10-C

S4iC S4-C'

081113 - HOLLOW METAL FRAME ANDDOOR, SEE DOOR OPENING SCHEDULE.

M10-D

07 92 00.B2 - JOINT SEALANT

07 92 00.B1 - JOINT SEALANT W/BACKER ROD

081113 - HOLLOW METAL FRAMEAND DOOR, SEE DOOR OPENINGSCHEDULE.

S4-C

'

METAL LINER PANEL,PBR PANEL. TYPICAL

STRUCTURAL GIRT

METAL WALL PANELS,AVP PANEL. TYPICAL

BATT INSULATION PERPRE-ENGINEEREDBUILDINGMANUFACTURER

PROVIDE ADDITIONALINSULATION/BLOCKING TOCLOSE AIR PATH FROMSERVICE BAY INTO OFFICESIDE OF THE BUILDING

083613 - OVERHEADSECTIONAL DOOR, ELECTRICWITH REMOTE.

PREFINISHED METALCOVER, FINISH TOMATCH AVP WALLPANEL

SECTIONAL DOOR FRAMING,SEE ELEVATION 5A/A-501.

STEEL PRE-ENGINEEREDBUILDING STRUCTURE

STRUCTURAL GIRT

METAL WALL PANELS,AVP PANEL. TYPICAL

METAL DOWNSPOUT

2 HOUR RATED WALLCONSTRUCTION. EXTEND WALLTO BOTTOM OF ROOFDECK/PANEL. CUT WALLAROUND ROOF PURLINS ANDSEAL WITH FIRE SEALANT

079200 - SEALANT, ENTIREPERIMETER OF FRAME, TYPICALBOTH SIDES.

081113 - DOOR & FRAME, REFDOOR SCHEDULE

09 22 16.C8 - INT STEEL STUDFRAMING, 6" @ 16" O.C.

09 29 00 - 2 LAYERS OF 5/8" FIRERATED GWB ON BOTH SIDES.

METAL TRIM/CLOSER. CONTINIUOUS

METAL WALL PANELS,AVP PANEL. TYPICAL

2-HOUR FIRE BARRIER ABOVE 2'-8" AFF

0' -

6"

3' -

0"

4' -

0"

0' - 6"

0' - 6"

0' - 6"

FINISH GRADE

CONCRETE FOOTING,MIN. 6" COVER.

BOLLARD, 6" DIAMETER, 1/4"MIN. THICK, GALVANIZEDPIPE FILLED WITHCONCRETE

CONCRETE CROWN CAP,1/2" HIGHER THAN THEPIPE.

PRIME AND PAINT BOLLARDWITH HIGH PERFORMANCECOATING SYSTEM.

2-HOUR FIRE BARRIER BELOW 2'-8" AFF

METAL WALL PANELS,AVP PANEL. TYPICAL

2-HOUR RATED BARRIERWALL CONSTRUCTION.EXTEND WALL FROMFINISH FLOOR TO 2'-8"AFF.

079200 - SEALANT,ENTIRE PERIMETER OFFRAME, BOTH SIDES.TYPICAL

METAL TRIM/CLOSER,CONTINUOUS.

081113 - DOOR &FRAME, REF DOORSCHEDULE

PROVIDE FIREBLOCKING/SEALANT TOCONTINUE FIRE BARRIER TOEXTERIOR WALL PANEL.

N

123456

A

B

C

D

E

123456

A

B

C

D

E

Project No.

Project Date

Produced

These Drawings and Specifications, and all copiesthereof are and shall remain the property and copyright ofthe Architect. They shall be used only with respect to this

Project and are not to be used on any other Project orWork without prior written permission from the Architect.

KEY PLAN

6/1

3/2

017 2

:41:2

3 P

M

C:\

_R

evitLocal\2016-0

10.G

TC

_B

ldg001_A

_201

6\2

016-0

10.G

TC

_B

ldg001_A

_2

016_tn

ing.r

vt

2016-010.GTC

06.12.2017

TYPICAL DETAILS -BUILDING A & B

A-501

Designer Author

GreencastleCommunity School

Corporation

GreencastleTransportation

Center

2016-0

10.G

TC

_G

reencastle C

om

munity S

chool C

orp

ora

tion_G

reencastle T

ransport

ation C

ente

r_

800 Tennessee StreetGreencastle, IN 46135

A-5

01_ T

YP

ICA

L D

ET

AIL

S -

BU

ILD

ING

A &

B

1" = 1'-0"1A

PLAN DETAIL

1" = 1'-0"1B

PLAN DETAIL

1" = 1'-0"1C

PLAN DETAIL

1" = 1'-0"1D

PLAN DETAIL

1" = 1'-0"1E

PLAN DETAIL

1" = 1'-0"2E

PLAN DETAIL

1" = 1'-0"2D

PLAN DETAIL 1" = 1'-0"

4DPLAN DETAIL

1" = 1'-0"2B

PLAN DETAIL

1" = 1'-0"2A

PLAN DETAIL - BUS STOR BLDG B 1" = 1'-0"

5APLAN DETAIL - BUS STOR BLDG B

1/2" = 1'-0"3B

PIPE BOLLARD DETAIL

# Revision Date

1" = 1'-0"4A

2-HOUR BARRIER PLAN DETAIL - BUS STOR BLDG B

Page 10: Abbreviations General Roof Plan Notes General Plan …keymarkcompany.com/sites/default/files/projects/5.4_architectural.pdf · glass block glue laminated wood government ... (moulding)

GENERAL NOTES

A. This Door Schedule(s) is furnished for whatever assistance it may afford theContractor. Do not consider it as entirely inclusive. Carefully examine the Drawings(especially the Floor Plans) and the Specifications to determine the extent of door andframe quantities required (including interior borrowed lite or sidelite openings). Shouldany particular door, frame, or interior borrowed lite or sidelite shown on the Drawings beinadvertently omitted from this Schedule, supply same as required for similar openings.

B. The "QTY" column designates the number of leaves in the opening. The "DoorWidth" column designates the total width of all leaves. In multiple leaf conditions, theleaves shall equally divide the "Door Width" unless noted otherwise; however, the activeleaf shall not be less than 3'-0" wide.

C. Door Type "X" denotes a frame with no door such as a borrowed lite, referenceFrame Elevations.

D. An asterisk (*) in a dimension denotes a width that varies, reference plans, elevations,details and schedules.

E. Verify locksets with the Owner during submittals.

F. All door frames shall be hollow metal unless noted otherwise.

G. All door frames in masonry wall shall have a 4" head unless noted otherwise.

H. All hollow metal door frames in stud walls shall be wrap-around frames and all hollowmetal door frames in masonry walls shall be butt frames unless noted otherwise.

ABBREVIATIONS

AL AluminumHM Hollow MetalST SteelWD WoodTG Tempered GlazingIG Insulated GlazingLG Laminated GlazingFG Frosted GlazingSP Spandrel Panel

DOOR & FRAME SCHEDULE NOTESSee Door Schedule

1. Provide 4" head at door frame.

SEE SCHED.

SE

E S

CH

ED

.

F

SEE SCHED.

SE

E S

CH

ED

.

NV

3' -

6"

2' -

10"

0' - 6" 0' - 6"

F1

0' - 2" 0' - 2"

0' -

2"

SE

E S

CH

ED

.

SEE SCHED.

N

123456

A

B

C

D

E

123456

A

B

C

D

E

Project No.

Project Date

Produced

These Drawings and Specifications, and all copiesthereof are and shall remain the property and copyright ofthe Architect. They shall be used only with respect to this

Project and are not to be used on any other Project orWork without prior written permission from the Architect.

KEY PLAN

6/1

3/2

017 2

:41:2

5 P

M

C:\

_R

evitLocal\2016-0

10.G

TC

_B

ldg001_A

_201

6\2

016-0

10.G

TC

_B

ldg001_A

_2

016_tn

ing.r

vt

2016-010.GTC

06.12.2017

DOOR AND FRAMESCHEDULE - BUILDING

A&B

A-601

Designer Author

GreencastleCommunity School

Corporation

GreencastleTransportation

Center

2016-0

10.G

TC

_G

reencastle C

om

munity S

chool C

orp

ora

tion_G

reencastle T

ransport

ation C

ente

r_

800 Tennessee StreetGreencastle, IN 46135

A-6

01_ D

OO

R A

ND

FR

AM

E S

CH

ED

ULE

- B

UIL

DIN

G A

&B

1/8" = 1'-0"

5.4.601 - DOOR AND FRAME LEGEND

1/4" = 1'-0"

5.4.602 - DOOR PANEL ELEVATIONS

DOOR & FRAME SCHEDULE

MARK

DOOR PANEL FRAME

LABELHDWR

SET NOTES MARKTYPE QTY MATL GLAZ

SIZE

MARK MATL GLAZH W TH

A100 F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 6 A100

A101 F 1 HM TG 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 4 A101

A102 NV 1 WD TG 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 4 A102

A103A F 1 HM TG 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 3 A103A

A103B F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 6 A103B

A103C F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 5 1 A103C

A105 F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 7 A105

A106 F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 7 A106

A107A F 1 HM TG 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 3 A107A

A107B F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 3 1 A107B

A108 F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 9 A108

A109 F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 9 A109

A110 NV 1 WD TG 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 4 A110

A110A F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 8 A110A

A111 F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 8 A111

A112 F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 7 A112

A115 F 2 HM -- 7' - 0" 6' - 0" 0' - 1 3/4" F1 HM -- 10 1 A115

A116A F 2 HM -- 7' - 0" 6' - 0" 0' - 1 3/4" HM -- 11 A116A

A116B F 2 HM -- 7' - 0" 6' - 0" 0' - 1 3/4" F1 HM -- 10 1 A116B

A117 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 A117

A118 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 A118

A119 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 A119

A119A F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 2 A119A

A120 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 A120

A120A F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 2 A120A

B101 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B101

B102 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B102

B103 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B103

B104 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B104

B105 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B105

B105A F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 12 B105A

B106 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B106

B106A F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 12 B106A

B107 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B107

B107A F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 12 B107A

B108 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B108

B108A F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 12 B108A

B109 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B109

B110 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B110

B111 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B111

B112 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B112

B113 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B113

B114 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B114

B115 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B115

B116 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B116

B117 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B117

B117A F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 12 B117A

B118 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B118

B118A F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 12 B118A

B119 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B119

B119A F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 12 B119A

B120 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B120

B120A F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 12 B120A

B121 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B121

B122 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B122

B123 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B123

B124 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B124

B125 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B125

B126 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B126

B127 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B127

B128 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B128

B129 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B129

B129A F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 12 B129A

B130 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B130

B130A F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 12 B130A

B131 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B131

B131A F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 12 B131A

B132 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B132

B132A F 1 HM -- 7' - 0" 3' - 0" 0' - 1 3/4" F1 HM -- 12 B132A

B133 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B133

B134 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B134

B135 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B135

B136 OH 1 ST -- 12' - 0" 14' - 0" 0' - 3" -- 1 B136

1/4" = 1'-0"

5.4.603 - DOOR FRAME ELEVATIONS

# Revision Date