General Notes Nothing set forth in these Drawings shall release any Contractor from responsibility to provide appropriate quantities, field measurements, dimensional stability, installation, anchorage and coordination with other trades, or waive the Contractor's responsibility to identify and resolve deviations from the requirements of the Contract Documents, or waive the Contractor's responsibility to alert the Architect to errors or omissions contained therein. Each Contractor shall verify in the field all existing applicable conditions and dimensions shown on the Drawings and as pertinent to the intent of these Drawings. Any discrepancy discovered shall be brought to the attention of the Architect prior to the commencement of any Work affected by, or related to, such discrepancy. Each Contractor shall be responsible for all costs associated with, or caused by failure to comply with requirement. Each Contractor shall review in advance all portions of the Work to verify that the Work will not prohibit completion of the Project as intended in these Contract Documents. Any questions shall be promptly referred to the Architect for resolution. Vicinity Map Thoroughfare Map Each Contractor shall refer to the Project Manual for cleaning and disposal requirements. Each Contractor shall be responsible for the protection of all surfaces and finishes at interior and exterior of building. Damaged surfaces and finishes resulting from the performance of the Work shall be repaired at no cost to the Owner by the responsible Contractor to match existing to the satisfaction of the Owner. Each Contractor shall coordinate respective cutting and patching Work with the other Prime Contracts. Each Contractor shall become completely familiar with all aspects of the Work, even those areas designated to be provided by others. This familiarization includes full and complete understanding of the Work described on all Sheets of the Drawings and in all Sections of the Project Manual. Failure by the Contractor to become completely familiar and cognizant of all aspects of the Work shall not relieve the Contractor of the responsibility to provide materials, assemblies, or services indicated in the Contract Documents. Drawing Index 2016-010.GTC 06.12.2017 Greencastle Transportation Center Greencastle Community School Corporation Greencastle Community School Corporation Greencastle Transportation Center 800 Tennessee Street Greencastle, IN 46135 2016-010.GTC G-000 1 - General G-000 COVER SHEET G-010 FIRE & LIFE SAFETY PLANS 2 - Site C-001 SITE GENERAL NOTES & ABBREVIATIONS 1 OF 1 TOPOGRAPHIC LAND SURVEY CD101 SITE DEMOLITION PLAN CL101 SITE LAYOUT PLAN CL501 SITE LAYOUT DETAILS CG101 SITE GRADING PLAN CU101 SITE UTILITY PLAN CU501 SITE UTILITY DETAILS CE101 EROSION CONTROL PLAN CE501 EROSION CONTROL DETAILS CE502 EROSION CONTROL DETAILS LP101 LANDSCAPE PLAN LP501 LANDSCAPE DETAILS 3 - Structural SF1A1 FOUNDATION PLANS - BUILDINGS A & B S-401 SECTIONS AND DETAILS S-402 TYPICAL FOUNDATION DETAILS S-501 STRUCTURAL NOTES 4 - Architectural A-001 ARCHITECTURAL GENERAL NOTES AND ABBREVIATIONS AF1A1 FIRST FLOOR PLANS - TRANSPORTATION BUILDING A AF1B1 FIRST FLOOR PLANS - BUS STORAGE BUILDING B AR100 ROOF PLAN & ROOF DETAILS - BUILDINGS A & B A-201 EXTERIOR BUILDING ELEVATIONS - BUILDING A & B A-301 BUILDING SECTIONS - BUILDING A & B A-311 WALL SECTIONS - BUILDING A A-312 WALL SECTIONS - BUILDING A & B A-501 TYPICAL DETAILS - BUILDING A & B A-601 DOOR AND FRAME SCHEDULE - BUILDING A&B 7 - Mechanical M-001 MECHANICAL SYMBOLS AND ABBREVIATIONS MH1A1 FIRST FLOOR HVAC & PIPING PLAN- TRANSPORTATION BLDG M-501 MECHANICAL DETAILS M-601 MECHANICAL SCHEDULES 8 - Plumbing P-001 PLUMBING SYMBOLS AND ABBREVIATIONS PF1A1 FOUNDATION, FIRST FLOOR, AND ROOF PLUMBING PLANS P-501 PLUMBING DETAILS P-502 PLUMBING ISOMETRICS P-601 PLUMBING SCHEDULES 9 - Electrical E-001 SYMBOLS & ABBREVIATIONS ES100 SITE ELECTRICAL PLAN ES101 SITE PHOTOMETRIC PLAN EL1B1 BUS STORAGE BUILDING ELECTRICAL LIGHTING PLANS EP1A1 TRANSPORTATION BUILDING ELECTRICAL PLANS EP1B1 BUS STORAGE BUILDING ELECTRICAL POWER PLANS E-501 ELECTRICAL DETAILS E-502 LIGHTING DETAILS E-601 ELECTRICAL SCHEDULES E-602 PANELBOARD SCHEDULES 10 - Telecommunications T-001 SYMBOLS & ABBREVIATIONS TS101 TELECOMMUNICATIONS SITE PLAN T-101 TELECOMMUNICATIONS PLAN T-501 TELECOMMUNICATIONS DETAILS

Transcript of Greencastle Community School Corporation C Greencastle...

Page 1: Greencastle Community School Corporation C Greencastle ...keymarkcompany.com/sites/default/files/projects/5.1_general.pdfa-201 exterior building elevations - building a & b a-301 building

General NotesNothing set forth in these Drawings shall release any Contractor from responsibility to provideappropriate quantities, field measurements, dimensional stability, installation, anchorage andcoordination with other trades, or waive the Contractor's responsibility to identify and resolvedeviations from the requirements of the Contract Documents, or waive the Contractor'sresponsibility to alert the Architect to errors or omissions contained therein.Each Contractor shall verify in the field all existing applicable conditions and dimensions shown onthe Drawings and as pertinent to the intent of these Drawings. Any discrepancy discovered shall bebrought to the attention of the Architect prior to the commencement of any Work affected by, orrelated to, such discrepancy.Each Contractor shall be responsible for all costs associated with, or caused by failure to complywith requirement.Each Contractor shall review in advance all portions of the Work to verify that the Work will notprohibit completion of the Project as intended in these Contract Documents. Any questions shall bepromptly referred to the Architect for resolution.

Vicinity Map Thoroughfare Map

Each Contractor shall refer to the Project Manual for cleaning and disposal requirements.Each Contractor shall be responsible for the protection of all surfaces and finishes at interior andexterior of building. Damaged surfaces and finishes resulting from the performance of the Workshall be repaired at no cost to the Owner by the responsible Contractor to match existing to thesatisfaction of the Owner.Each Contractor shall coordinate respective cutting and patching Work with the other PrimeContracts.Each Contractor shall become completely familiar with all aspects of the Work, even those areasdesignated to be provided by others. This familiarization includes full and complete understandingof the Work described on all Sheets of the Drawings and in all Sections of the Project Manual.Failure by the Contractor to become completely familiar and cognizant of all aspects of the Workshall not relieve the Contractor of the responsibility to provide materials, assemblies, or servicesindicated in the Contract Documents.

Drawing Index

2016-0

10.G

TC

06.1

2.2

017

Gre

encast le T

ransport

ation C

ente

rG

reencastle C

om

munity S

chool C

or p

ora

t ion

Greencastle Community School CorporationGreencastle Transportation Center

800 Tennessee StreetGreencastle, IN 46135

2016-010.GTC

G-000

1 - General

G-000 COVER SHEET

G-010 FIRE & LIFE SAFETY PLANS

2 - Site

C-001 SITE GENERAL NOTES & ABBREVIATIONS

1 OF 1 TOPOGRAPHIC LAND SURVEY

CD101 SITE DEMOLITION PLAN

CL101 SITE LAYOUT PLAN

CL501 SITE LAYOUT DETAILS

CG101 SITE GRADING PLAN

CU101 SITE UTILITY PLAN

CU501 SITE UTILITY DETAILS

CE101 EROSION CONTROL PLAN

CE501 EROSION CONTROL DETAILS

CE502 EROSION CONTROL DETAILS

LP101 LANDSCAPE PLAN

LP501 LANDSCAPE DETAILS

3 - Structural

SF1A1 FOUNDATION PLANS - BUILDINGS A & B

S-401 SECTIONS AND DETAILS

S-402 TYPICAL FOUNDATION DETAILS

S-501 STRUCTURAL NOTES

4 - Architectural

A-001 ARCHITECTURAL GENERAL NOTES AND ABBREVIATIONS

AF1A1 FIRST FLOOR PLANS - TRANSPORTATION BUILDING A

AF1B1 FIRST FLOOR PLANS - BUS STORAGE BUILDING B

AR100 ROOF PLAN & ROOF DETAILS - BUILDINGS A & B

A-201 EXTERIOR BUILDING ELEVATIONS - BUILDING A & B

A-301 BUILDING SECTIONS - BUILDING A & B

A-311 WALL SECTIONS - BUILDING A

A-312 WALL SECTIONS - BUILDING A & B

A-501 TYPICAL DETAILS - BUILDING A & B

A-601 DOOR AND FRAME SCHEDULE - BUILDING A&B

7 - Mechanical

M-001 MECHANICAL SYMBOLS AND ABBREVIATIONS

MH1A1 FIRST FLOOR HVAC & PIPING PLAN- TRANSPORTATIONBLDG

M-501 MECHANICAL DETAILS

M-601 MECHANICAL SCHEDULES

8 - Plumbing

P-001 PLUMBING SYMBOLS AND ABBREVIATIONS

PF1A1 FOUNDATION, FIRST FLOOR, AND ROOF PLUMBING PLANS

P-501 PLUMBING DETAILS

P-502 PLUMBING ISOMETRICS

P-601 PLUMBING SCHEDULES

9 - Electrical

E-001 SYMBOLS & ABBREVIATIONS

ES100 SITE ELECTRICAL PLAN

ES101 SITE PHOTOMETRIC PLAN

EL1B1 BUS STORAGE BUILDING ELECTRICAL LIGHTING PLANS

EP1A1 TRANSPORTATION BUILDING ELECTRICAL PLANS

EP1B1 BUS STORAGE BUILDING ELECTRICAL POWER PLANS

E-501 ELECTRICAL DETAILS

E-502 LIGHTING DETAILS

E-601 ELECTRICAL SCHEDULES

E-602 PANELBOARD SCHEDULES

10 - Telecommunications

T-001 SYMBOLS & ABBREVIATIONS

TS101 TELECOMMUNICATIONS SITE PLAN

T-101 TELECOMMUNICATIONS PLAN

T-501 TELECOMMUNICATIONS DETAILS

Page 2: Greencastle Community School Corporation C Greencastle ...keymarkcompany.com/sites/default/files/projects/5.1_general.pdfa-201 exterior building elevations - building a & b a-301 building

SERVICE BAYS IN TOTAL ARE LESSTHAN 5,000 SQ FT, THUS NO FIREBARRIERS OR SPRINKLERS AREREQUIRED.

2-H

OU

R F

IRE

BA

RR

IER

2-H

OU

R F

IRE

BA

RR

IER

2-H

OU

R F

IRE

BA

RR

IER

2-H

OU

R F

IRE

BA

RR

IER

2-H

OU

R F

IRE

BA

RR

IER

THIS SPACE IS LESS THAN 5,000 SF,THUS SPRINKLERS ARE NOT REQUIRED.

THIS SPACE IS LESS THAN 5,000 SF,THUS SPRINKLERS ARE NOT REQUIRED.

THIS SPACE IS LESS THAN 5,000 SF,THUS SPRINKLERS ARE NOT REQUIRED.

THIS SPACE IS LESS THAN 5,000 SF,THUS SPRINKLERS ARE NOT REQUIRED.

THIS SPACE IS LESS THAN 5,000 SF,THUS SPRINKLERS ARE NOT REQUIRED.

THIS SPACE IS LESS THAN 5,000 SF,THUS SPRINKLERS ARE NOT REQUIRED.

PROJECT DESCRIPTION:

New Transportation Center for Greencastle Community School Corporation.This project consist of two new buildings for the Greencastle Community SchoolCorporation's Transportation use.The first building is an 8000 square foot single-story transportation/bus maintenancebuilding and office. It consists of reception, offices, driver's lounge, restrooms andstorage for the school transportation department. It also has a four-bay work area forthe maintenance and repair of the district's school buses and vehicles.The second building is a 29,700 square foot bus storage building. It has 36 busbays to house all of the school district's buses and service vehicles. This building isdivided into six spaces with 2-hour fire barriers, thus each space is less than 5,000 sf.This building is used for the storage of the vehicles and no work will be performed here.

These building are mainly used by the staff and drivers of Greencastle CommunitySchools and not a public use facility.

Applicable Code: 2014 Indiana Building Code2014 Indiana Fire Code

Occupancy Classifications: Vehicle Maintenance, Parts Storage- S-1 Occupancy [311.2]

Office and administrative use- B Occupancy [304.1]

Allowable Area: Tabular Area: 9,000 sf Table 503Frontage Increase: +6,750 sf 506.2Total allowable area: 15,750 sfActual area: 8,000 sf

Building Elements: Building elements, including bearing walls and roof structure arepermitted to be of nonrated combustible construction

[Table 601]Exterior walls are permitted to be nonrated, combustibleconstruction, where having more than 10 feet of fire separationdistance [Table 602]

PROJECT CODE SUMMARY - TRANSPORTATION BLDG "A"

Construction Type: Type VB Construction permitted based upon allowable area[503.1]

Fire Barrier: 3-hour fire barrier provided to limit S-1 Occupancy fire area to lessthan 5,000 sq ft as required for nonsprinklered S-1 Occupancyrepair garage for commercial vehicles

[Table 707.3.10, Sec. 901.7 and 903.2.9.1]

Incidental Use Areas: None applicable to this project [Table 509]

Exit Access Travel Distance: The maximum travel distance to an exterior exit is permitted to be amaximum of 200 feet [1016.1]

Panic Hardware: Panic hardware is not required for either an S-1 Occupancy or a BOccupancy [1008.1.10]

Automatic Sprinklers: Automatic sprinklers are not required based upon an S-1 Occupancyfire area of less than 5,000 square feet [903.2.9.1]Automatic sprinklers are not otherwise required throughout thebuilding based upon provision of required exterior openings on atleast one side of the building [903.2.11.1]

Fire Alarm System: Not required for S-1 Occupancy or B Occupancy with an occupantload of less than 500 [907.2]

Fire Fighting Access Road: Fire fighting access road required to within 150 feet of all exteriorwalls of the building [503, IFC]

Applicable Code: 2014 Indiana Building Code2014 Indiana Fire Code

Occupancy Classifications: Bus storage- S-2 Occupancy [311.3]

Allowable Area: Unlimited area permitted for 1-story S-2 Occupancies surroundedby a minimum of 60-ft frontage [507.2]

Building Elements: Building elements, including bearing walls and roof structure arepermitted to be of nonrated combustible construction

[Table 601]Exterior walls are permitted to be nonrated, combustibleconstruction, where having more than 10 feet of fire separationdistance [Table 602]

PROJECT CODE SUMMARY - BUS STORAGE BLDG "B"

Construction Type: Type VB Construction permitted based upon allowable area for 1-story S-2 Occupancies surrounded by a minimum of 60-ft frontage

[503.1]

Fire Barrier: 2-hour fire barriers provided to limit S-2 Occupancy fire area to lessthan 5,000 sq ft as required for nonsprinklered S-2 Occupancystorage of commercial vehicles or buses

[Table 707.3.10, Sec. 901.7 and 903.2.10.1]

Incidental Use Areas: None applicable to this project [Table 509]

Exit Access Travel Distance: The maximum travel distance to an exterior exit is permitted to be amaximum of 200 feet [1016.1]

Panic Hardware: Panic hardware is not required for either an S-2 Occupancy or a BOccupancy [1008.1.10]

Automatic Sprinklers: Automatic sprinklers are not required based upon an S-2 Occupancyfire area of less than 5,000 square feet [903.2.10.1]Automatic sprinklers are not otherwise required throughout thebuilding based upon provision of required exterior openings on atleast one side of the building [903.2.11.1]

Fire Alarm System: Not required for S-2 Occupancy [907.2]

Fire Fighting Access Road: Fire fighting access road required to within 150 feet of all exteriorwalls of the building [503, IFC]

General Comments: The Bus Storage Building "B" is not a conditioned space and willnot be occupied other than when buses drive in or out.

N

123456

A

B

C

D

E

123456

A

B

C

D

E

Project No.

Project Date

Produced

These Drawings and Specifications, and all copiesthereof are and shall remain the property and copyright ofthe Architect. They shall be used only with respect to this

Project and are not to be used on any other Project orWork without prior written permission from the Architect.

KEY PLAN

6/1

3/2

017 2

:45:4

1 P

M

C:\

_R

evitLocal\2016-0

10.G

TC

_B

ldg001_A

_201

6\2

016-0

10.G

TC

_B

ldg001_A

_2

016_tn

ing.r

vt

2016-010.GTC

06.12.2017

FIRE & LIFE SAFETYPLANS

G-010

Designer Author

GreencastleCommunity School

Corporation

GreencastleTransportation

Center

2016-0

10.G

TC

_G

reencastle C

om

munity S

chool C

orp

ora

tion_G

reencastle T

ransport

ation C

ente

r_

800 Tennessee StreetGreencastle, IN 46135

G-0

10_ F

IRE

& L

IFE

SA

FE

TY

PLA

NS

3/32" = 1'-0"1C

TRANSPORTATION BLDG FLOOR PLAN - FIRE & LIFE SAFETY

3/32" = 1'-0"1A

BUS STORAGE BLDG FLOOR PLAN - FIRE & LIFE SAFETY

8,000 square foot

29,700 square foot

# Revision Date