A38 - Bristol Road

5
RE GAS GAS GAS g SE70 116.487 SE71 118.917 Priory Road A38 - Bristol Road Priory Road Priory Road Key: Scheme boundary Proposed alignment Existing survey/OS information Tactile / corduroy paving construction - Refer to Footways and Paved Areas drawings B2309009-JAC-1100-DR-1101 to 1105 0.5m cycle segregation island Proposed Footways and Paved Areas - Refer to Footways and Paved Areas drawings B2309009-JAC-1100-DR-1101 to 1105 Proposed Cycleway - Refer to footways and Paved Areas drawings B2309009-JAC-1100-DR-1101 to 1105 Shared footway - Refer to footways and Paved Areas drawings B2309009-JAC-1100-DR-1101 to 1105 Visirail as shown on drawings - Refer to Pedestrian guardrail drawing B2309009-JAC-0400-DR-0402 and as per BCC SD HW/4.02 Existing / Proposed Lighting column - Refer to Street Lighting drawings B2309009-JAC-1300-DR-1301 to 1305 Proposed Traffic Sign and pole - Refer to Traffic Sign drawings B2309009-JAC-1200-DR-1211 to 1215 Traffic Bollard - Refer to Traffic Sign drawings B2309009-JAC-1200-DR-1211 to 1215 Existing relocated information board Existing Edgbaston Road fingerboard sign to be relocated Proposed bus shelter -Specification to be agreed with TfWM Proposed Road Markings - Refer to Road Markings drawings B2309009-JAC-1200-DR-1201 to 1205 Proposed Traffic Signal - Refer to Traffic Signal drawings B2309009-JAC-1200-DR-1221 to 1224 Proposed Earthworks and verge Proposed bin - Broxap Derby Standard Liter Bin - BX45 2550-S (or similar approved) with pyramid top fixed to permanent position with fixing kit. Colour - Powder coated RAL 9005 with gold band. Proposed mini feeder pillar Earthworks Slope Gradient 1: x Revision Cloud x 1 Drawing status Drawing number Scale Client no. Jacobs No. Drawing title DO NOT SCALE Rev Project Client G N W I A R D T U A O A D C P:\B2309009 - Pershore Rd- Priory Rd Jct Detailed Design\008 CADD\0000 General Arrangement\B2309009-JAC-0000-DR-0001 (Sheet 1 of 5) R02.dwg - 30/09/2020 15:58:55 - SHEET 01 - GriceD Apprv'd Purpose of revision Rev Rev. Date Drawn Checkd Rev'd © Copyright 2020 Jacobs U.K. Limited. The concepts and information contained in this document are the property of Jacobs. Use or copying of this document in whole or in part without the written permission of Jacobs constitutes an infringement of copyright. Limitation: This drawing has been prepared on behalf of, and for the exclusive use of Jacobs' Client, and is subject to, and issued in accordance with, the provisions of the contract between Jacobs and the Client. Jacobs accepts no liability or responsibility whatsoever for, or in respect of, any use of, or reliance upon, this drawing by any third party. PERSHORE ROAD - PRIORY ROAD JUNCTION DETAILED DESIGN GENERAL ARRANGEMENT SHEET 1 OF 5 SUITABLE FOR APPROVAL 1:250 @ A1 B2309009 B2309009-JAC-0000-DR-0001 R02 7th Floor, 2 Colmore Square, 38 Colmore Circus Queensway, Birmingham, B4 6BN Tel:+44(0)121 237 4000 www.jacobs.com REPRODUCED FROM ORDNANCE SURVEY MAPS WITH PERMISSION FROM THE CONTROLLER OF HM STATIONERY OFFICE. CROWN COPYRIGHT RESERVED. LICENCE No. 0100031673 2018. CONTINUED ON SHEET 2 SHEET 01 SHEET 02 SHEET 03 SHEET 04 SHEET 05 R02 30/09/20 CONCRETE BOLLARD REMOVED, SHARED HATCH AND KEY UPDATED, BOUNDARY ALTERED, TIE IN DEFINED DG MP MP AL R01 27/05/20 AMENDMENTS MADE DG TS TS AL R00 20/03/20 SUITABLE FOR APPROVAL BV TS DM AL 3.0m 3.0m 1.9m 2.0m 4.3m 3.0m Odell Place traffic island extended Tie into A38 BCR scheme Tie into A38 BCR scheme Existing substation Notes: 1) Drawing to be printed in colour to enable correct viewing of symbols. 2) Do not scale. 3) This drawing to be read in conjunction with all other relevant contract drawings and documents. 4) The Contractor shall verify the presence and location of all services before undertaking any work in any area of the site by carrying out a full non-intrusive survey of the entire site before commencing the works. 5) For cross sections refer to cross section drawings B2309009-JAC-0000-DR-0041 to 0044 and B2309009-JAC-0000-DR-0051 to 0065 Location Plan - Sheet 1 10m 0m 15m 5m 5m Scale 1:250 All site activities shall be carried out in accordance with the Contractor's Construction Phase Plan and Safe Work Method Statements/Risk Assessments. In addition to the hazards/risks normally associated with the type of work detailed on this drawing, note the following: WORK CAN ONLY BE CARRIED OUT BY SUITABLY TRAINED AND BRIEFED PERSONNEL. CONSTRUCTION 1) Working in proximity to live traffic and construction plant . 2) All existing services should be located on site as required by the contractor prior to any construction works being undertaken. 3) Ensure adequate liaison is undertaken with residents and businesses within the site extents to ensure safe access / egress arrangements are communicated. 4) Vibration from works operations should be avoided in the vicinity of buildings and utilities. 5) Any works to be undertaken at night should have adequate lighting available, and regulations regarding noise must be followed. 6) Contact with carcinogenic tar based material. 7) Dust inhalation, noise and excessive vibration. 8) High temperatures from asphalt laying process resulting in burns and fume inhalation. SAFETY, HEALTH AND ENVIRONMENTAL (SHE) INFORMATION 7.7m Ducting and feeder pillar to new bus shelter to be installed by contractor

Transcript of A38 - Bristol Road

RE

GAS

GAS

GAS

g

S

E

7

0

1

1

6

.

4

8

7

S

E

7

1

1

1

8

.

9

1

7

P

r

i

o

r

y

R

o

a

d

A

3

8

-

B

r

i

s

t

o

l

R

o

a

d

P

r

i

o

r

y

R

o

a

d

P

r

i

o

r

y

R

o

a

d

Key:

Scheme boundary

Proposed alignment

Existing survey/OS information

Tactile / corduroy paving construction - Refer to

Footways and Paved Areas drawings

B2309009-JAC-1100-DR-1101 to 1105

0.5m cycle segregation island

Proposed Footways and Paved Areas - Refer to

Footways and Paved Areas drawings

B2309009-JAC-1100-DR-1101 to 1105

Proposed Cycleway - Refer to footways and Paved Areas

drawings B2309009-JAC-1100-DR-1101 to 1105

Shared footway - Refer to footways and Paved Areas drawings

B2309009-JAC-1100-DR-1101 to 1105

Visirail as shown on drawings - Refer to Pedestrian guardrail

drawing B2309009-JAC-0400-DR-0402 and as per BCC SD

HW/4.02

Existing / Proposed Lighting column - Refer to Street

Lighting drawings B2309009-JAC-1300-DR-1301 to 1305

Proposed Traffic Sign and pole - Refer to Traffic Sign

drawings B2309009-JAC-1200-DR-1211 to 1215

Traffic Bollard - Refer to Traffic Sign

drawings B2309009-JAC-1200-DR-1211 to 1215

Existing relocated information board

Existing Edgbaston Road fingerboard sign to be relocated

Proposed bus shelter -Specification to be agreed

with TfWM

Proposed Road Markings - Refer to Road Markings

drawings B2309009-JAC-1200-DR-1201 to 1205

Proposed Traffic Signal - Refer to Traffic Signal drawings

B2309009-JAC-1200-DR-1221 to 1224

Proposed Earthworks and verge

Proposed bin - Broxap Derby Standard Liter Bin - BX45

2550-S (or similar approved) with pyramid top fixed to

permanent position with fixing kit. Colour - Powder coated

RAL 9005 with gold band.

Proposed mini feeder pillar

Earthworks Slope Gradient 1: x

Revision Cloud

x

1

Drawing status

Drawing number

Scale

Client no.

Jacobs No.

Drawing title

DO NOT SCALE

Rev

Project

Client

G

N

W

I

A

R

D

T

U

A

O

A

D

C

P:\B

2309009 - P

ersho

re

R

d- P

rio

ry R

d Jct D

etailed

D

esig

n\0

08 C

AD

D\000

0 G

ene

ral A

rrangem

ent\B

230

900

9-JA

C-00

00-D

R-0

00

1 (S

he

et 1

o

f 5

) R

02

.d

wg

- 3

0/09

/2

02

0 1

5:5

8:5

5 - S

HE

ET

0

1 - G

rice

D

Apprv'dPurpose of revision

Rev Rev. Date Drawn CheckdRev'd

© Copyright 2020 Jacobs U.K. Limited. The concepts and information contained in this document are the property of Jacobs.

Use or copying of this document in whole or in part without the written permission of Jacobs constitutes an infringement of

copyright. Limitation: This drawing has been prepared on behalf of, and for the exclusive use of Jacobs' Client, and is subject

to, and issued in accordance with, the provisions of the contract between Jacobs and the Client. Jacobs accepts no liability or

responsibility whatsoever for, or in respect of, any use of, or reliance upon, this drawing by any third party.

PERSHORE ROAD - PRIORY ROAD

JUNCTION DETAILED DESIGN

GENERAL ARRANGEMENT

SHEET 1 OF 5

SUITABLE FOR APPROVAL

1:250 @ A1

B2309009

B2309009-JAC-0000-DR-0001 R02

7th Floor, 2 Colmore Square, 38 Colmore Circus

Queensway, Birmingham, B4 6BN

Tel:+44(0)121 237 4000 www.jacobs.com

REPRODUCED FROM ORDNANCE SURVEY MAPS WITH PERMISSION

FROM THE CONTROLLER OF HM STATIONERY OFFICE. CROWN

COPYRIGHT RESERVED. LICENCE No. 0100031673 2018.

C

O

N

T

I

N

U

E

D

O

N

S

H

E

E

T

2

S

H

E

E

T

0

1

S

H

E

E

T

0

2

SHEET 03

SHEET 04

SHEET 05

R02 30/09/20

CONCRETE BOLLARD REMOVED, SHARED HATCH AND

KEY UPDATED, BOUNDARY ALTERED, TIE IN DEFINED

DG MPMP AL

R01 27/05/20 AMENDMENTS MADE DG TSTS AL

R00 20/03/20 SUITABLE FOR APPROVAL BV TS DM AL

3.0m

3.0m

1.9m

2.0m

4.3m

3.0m

Odell Place traffic island extended

Tie into A38 BCR scheme

Tie into A38 BCR scheme

Existing substation

Notes:

1) Drawing to be printed in colour to enable correct viewing of symbols.

2) Do not scale.

3) This drawing to be read in conjunction with all other relevant contract

drawings and documents.

4) The Contractor shall verify the presence and location of all services

before undertaking any work in any area of the site by carrying out a full

non-intrusive survey of the entire site before commencing the works.

5) For cross sections refer to cross section drawings

B2309009-JAC-0000-DR-0041 to 0044 and

B2309009-JAC-0000-DR-0051 to 0065

Location Plan - Sheet 1

10m0m 15m5m5m

Scale 1:250

All site activities shall be carried out in accordance with the Contractor's Construction

Phase Plan and Safe Work Method Statements/Risk Assessments. In addition to the

hazards/risks normally associated with the type of work detailed on this drawing, note

the following:

WORK CAN ONLY BE CARRIED OUT BY SUITABLY TRAINED AND BRIEFED

PERSONNEL.

CONSTRUCTION

1) Working in proximity to live traffic and construction plant.

2) All existing services should be located on site as required by the contractor prior to any construction

works being undertaken.

3) Ensure adequate liaison is undertaken with residents and businesses within the site extents to

ensure safe access / egress arrangements are communicated.

4) Vibration from works operations should be avoided in the vicinity of buildings and utilities.

5) Any works to be undertaken at night should have adequate lighting available, and regulations

regarding noise must be followed.

6) Contact with carcinogenic tar based material.

7) Dust inhalation, noise and excessive vibration.

8) High temperatures from asphalt laying process resulting in burns and fume inhalation.

SAFETY, HEALTH AND ENVIRONMENTAL (SHE) INFORMATION

7.7m

Ducting and feeder pillar to new bus

shelter to be installed by contractor

AutoCAD SHX Text
120.1m
AutoCAD SHX Text
Shelter
AutoCAD SHX Text
BUS
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STOP
AutoCAD SHX Text
SLOW
AutoCAD SHX Text
BUS
AutoCAD SHX Text
25.0
AutoCAD SHX Text
50.0
AutoCAD SHX Text
75.0
AutoCAD SHX Text
100.0
AutoCAD SHX Text
125.0

ST

S

E

0

2

1

1

3

.

1

1

2

P

e

r

s

h

o

r

e

R

o

a

d

ST

ST

ST

ST

ST

ST

ST

ST

ST

ST

ST

STST

STST

STST

ST

STST

STST

STST

ST

ST

ST

ST

ST

ST

FH

GAS

GASGAS

GAS

GAS

TP

TP

TV

TV

M

S

0

1

1

1

2

.

8

2

8

S

E

0

11

1

2

.

7

1

9

S

E

0

3

1

1

1

.

8

5

9

S

E

0

A

1

1

2

.

2

0

1

S

E

0

21

1

3

.

1

1

2

1

1

3

.

0

1

1

3

.

0

1

1

5

.

0

1

1

4

.

0

1

1

4

.

0

1

1

4

.

0

1

1

3

.

0

1

1

3

.

0

P

r

i

o

r

y

R

o

a

d

P

e

r

s

h

o

r

e

R

o

a

d

P

e

r

s

h

o

r

e

R

o

a

d

E

d

g

b

a

s

t

o

n

R

o

a

d

Extents of trees to be removed,

see Site Clearance drawing

B2309009-JAC-0200-DR-0202

R

a

m

p

E

x

t

e

n

t

s

Existing TRO marking to

be refreshed on new

kerbline

Bus lay-by adjusted to

suit new channel line

Tie in to existing shared

use footway

Key:

Scheme boundary

Proposed alignment

Existing survey/OS information

Tactile / corduroy paving construction - Refer to

Footways and Paved Areas drawings

B2309009-JAC-1100-DR-1101 to 1105

0.5m cycle segregation island

Proposed Footways and Paved Areas - Refer to

Footways and Paved Areas drawings

B2309009-JAC-1100-DR-1101 to 1105

Proposed Cycleway - Refer to footways and Paved Areas

drawings B2309009-JAC-1100-DR-1101 to 1105

Shared footway - Refer to footways and Paved Areas drawings

B2309009-JAC-1100-DR-1101 to 1105

Visirail as shown on drawings - Refer to Pedestrian guardrail

drawing B2309009-JAC-0400-DR-0402 and as per BCC SD

HW/4.02

Existing / Proposed Lighting column - Refer to Street

Lighting drawings B2309009-JAC-1300-DR-1301 to 1305

Proposed Traffic Sign and pole - Refer to Traffic Sign

drawings B2309009-JAC-1200-DR-1211 to 1215

Traffic Bollard - Refer to Traffic Sign

drawings B2309009-JAC-1200-DR-1211 to 1215

Relocated information board

Existing Edgbaston Road fingerboard sign to be relocated

Proposed bus shelter -Specification to be agreed with

TfWM

Proposed Road Markings - Refer to Road Markings

drawings B2309009-JAC-1200-DR-1201 to 1205

Proposed Traffic Signal - Refer to Traffic Signal drawings

B2309009-JAC-1200-DR-1221 to 1224

Proposed Earthworks and verge

Proposed bin - Broxap Derby Standard Liter Bin - BX45

2550-S (or similar approved) with pyramid top fixed to

permanent position with fixing kit. Colour - Powder coated

RAL 9005 with gold band.

Proposed mini feeder pillar

Earthworks Slope Gradient 1: x

Revision Cloud

x

1

Key:

Scheme boundary

Proposed alignment

Existing survey/OS information

Tactile / corduroy paving construction - Refer to

Footways and Paved Areas drawings

B2309009-JAC-1100-DR-1101 to 1105

0.5m cycle segregation island

Proposed Footways and Paved Areas - Refer to

Footways and Paved Areas drawings

B2309009-JAC-1100-DR-1101 to 1105

Proposed Cycleway - Refer to footways and Paved Areas

drawings B2309009-JAC-1100-DR-1101 to 1105

Shared footway - Refer to footways and Paved Areas drawings

B2309009-JAC-1100-DR-1101 to 1105

Visirail as shown on drawings - Refer to Pedestrian guardrail

drawing B2309009-JAC-0400-DR-0402 and as per BCC SD

HW/4.02

Existing / Proposed Lighting column - Refer to Street

Lighting drawings B2309009-JAC-1300-DR-1301 to 1305

Proposed Traffic Sign and pole - Refer to Traffic Sign

drawings B2309009-JAC-1200-DR-1211 to 1215

Traffic Bollard - Refer to Traffic Sign

drawings B2309009-JAC-1200-DR-1211 to 1215

Relocated information board

Existing Edgbaston Road fingerboard sign to be relocated

Proposed bus shelter -Specification to be agreed with

TfWM

Proposed Road Markings - Refer to Road Markings

drawings B2309009-JAC-1200-DR-1201 to 1205

Proposed Traffic Signal - Refer to Traffic Signal drawings

B2309009-JAC-1200-DR-1221 to 1224

Proposed Earthworks and verge

Proposed bin - Broxap Derby Standard Liter Bin - BX45

2550-S (or similar approved) with pyramid top fixed to

permanent position with fixing kit. Colour - Powder coated

RAL 9005 with gold band.

Proposed mini feeder pillar

Earthworks Slope Gradient 1: x

Revision Cloud

x

1

Drawing status

Drawing number

Scale

Client no.

Jacobs No.

Drawing title

DO NOT SCALE

Rev

Project

Client

G

N

W

I

A

R

D

T

U

A

O

A

D

C

P:\B

2309009 - P

ersho

re

R

d- P

rio

ry R

d Jct D

etailed

D

esig

n\0

08 C

AD

D\000

0 G

ene

ral A

rrangem

ent\B

230

900

9-JA

C-00

00-D

R-0

00

2 (S

he

et 2

o

f 5

) R

02

.d

wg

- 3

0/09

/2

02

0 16

:1

4:21

- S

HE

ET

0

2 - G

rice

D

Apprv'dPurpose of revision

Rev Rev. Date Drawn CheckdRev'd

© Copyright 2020 Jacobs U.K. Limited. The concepts and information contained in this document are the property of Jacobs.

Use or copying of this document in whole or in part without the written permission of Jacobs constitutes an infringement of

copyright. Limitation: This drawing has been prepared on behalf of, and for the exclusive use of Jacobs' Client, and is subject

to, and issued in accordance with, the provisions of the contract between Jacobs and the Client. Jacobs accepts no liability or

responsibility whatsoever for, or in respect of, any use of, or reliance upon, this drawing by any third party.

C

O

N

T

I

N

U

E

D

O

N

S

H

E

E

T

1

C

O

N

T

I

N

U

E

D

O

N

S

H

E

E

T

3

PERSHORE ROAD - PRIORY ROAD

JUNCTION DETAILED DESIGN

GENERAL ARRANGEMENT

SHEET 2 OF 5

SUITABLE FOR APPROVAL

1:250 @ A1

B2309009

B2309009-JAC-0000-DR-0002 R02

7th Floor, 2 Colmore Square, 38 Colmore Circus

Queensway, Birmingham, B4 6BN

Tel:+44(0)121 237 4000 www.jacobs.com

REPRODUCED FROM ORDNANCE SURVEY MAPS WITH PERMISSION

FROM THE CONTROLLER OF HM STATIONERY OFFICE. CROWN

COPYRIGHT RESERVED. LICENCE No. 0100031673 2018.

S

H

E

E

T

0

1

S

H

E

E

T

0

2

SHEET 03

SHEET 04

SHEET 05

R02 30/09/20

SHARED HATCH AND KEY UPDATED & TIE IN

DEFINED, FEEDER PILLAR REMOVED

DG MPMP AL

R01 27/05/20 AMENDMENTS MADE DG TSTS AL

R00 20/03/20 SUITABLE FOR APPROVAL BV TS MS AL

C

O

N

T

I

N

U

E

D

O

N

I

N

S

E

T

A

INSET A

Scale 1:500

Location Plan - Sheet 2

10m0m 15m5m5m

Scale 1:250

All site activities shall be carried out in accordance with the Contractor's Construction

Phase Plan and Safe Work Method Statements/Risk Assessments. In addition to the

hazards/risks normally associated with the type of work detailed on this drawing, note

the following:

WORK CAN ONLY BE CARRIED OUT BY SUITABLY TRAINED AND BRIEFED

PERSONNEL.

CONSTRUCTION

1) Working in proximity to live traffic and construction plant.

2) All existing services should be located on site as required by the contractor prior to any construction

works being undertaken.

3) Ensure adequate liaison is undertaken with residents and businesses within the site extents to

ensure safe access / egress arrangements are communicated.

4) Vibration from works operations should be avoided in the vicinity of buildings and utilities.

5) Any works to be undertaken at night should have adequate lighting available, and regulations

regarding noise must be followed.

6) Contact with carcinogenic tar based material.

7) Dust inhalation, noise and excessive vibration.

8) High temperatures from asphalt laying process resulting in burns and fume inhalation.

SAFETY, HEALTH AND ENVIRONMENTAL (SHE) INFORMATION

Notes:

1) Drawing to be printed in colour to enable correct viewing of symbols.

2) Do not scale.

3) This drawing to be read in conjunction with all other relevant contract

drawings and documents.

4) The Contractor shall verify the presence and location of all services

before undertaking any work in any area of the site by carrying out a full

non-intrusive survey of the entire site before commencing the works.

5) For cross sections refer to cross section drawings

B2309009-JAC-0000-DR-0041 to 0044 and

B2309009-JAC-0000-DR-0051 to 0065.

3

1

3

1

AutoCAD SHX Text
2
AutoCAD SHX Text
40
AutoCAD SHX Text
0.0
AutoCAD SHX Text
25.0
AutoCAD SHX Text
50.0
AutoCAD SHX Text
75.0
AutoCAD SHX Text
0.0
AutoCAD SHX Text
25.0
AutoCAD SHX Text
50.0
AutoCAD SHX Text
75.0
AutoCAD SHX Text
243
AutoCAD SHX Text
233
AutoCAD SHX Text
245
AutoCAD SHX Text
241
AutoCAD SHX Text
253
AutoCAD SHX Text
263
AutoCAD SHX Text
281
AutoCAD SHX Text
2
AutoCAD SHX Text
2a
AutoCAD SHX Text
8
AutoCAD SHX Text
8a
AutoCAD SHX Text
297
AutoCAD SHX Text
1 to 12
AutoCAD SHX Text
14 to 117
AutoCAD SHX Text
6a
AutoCAD SHX Text
6
AutoCAD SHX Text
4a
AutoCAD SHX Text
4
AutoCAD SHX Text
125.0
AutoCAD SHX Text
150.0
AutoCAD SHX Text
175.0
AutoCAD SHX Text
200.0
AutoCAD SHX Text
225.0
AutoCAD SHX Text
250.0
AutoCAD SHX Text
275.0
AutoCAD SHX Text
300.0
AutoCAD SHX Text
50.0
AutoCAD SHX Text
75.0
AutoCAD SHX Text
100.0
AutoCAD SHX Text
125.0
AutoCAD SHX Text
150.0
AutoCAD SHX Text
175.0
AutoCAD SHX Text
200.0
AutoCAD SHX Text
225.0
AutoCAD SHX Text
125.0
AutoCAD SHX Text
150.0
AutoCAD SHX Text
175.0
AutoCAD SHX Text
200.0
AutoCAD SHX Text
225.0
AutoCAD SHX Text
250.0
AutoCAD SHX Text
275.0
AutoCAD SHX Text
300.0
AutoCAD SHX Text
50.0
AutoCAD SHX Text
75.0
AutoCAD SHX Text
100.0
AutoCAD SHX Text
125.0
AutoCAD SHX Text
150.0
AutoCAD SHX Text
175.0
AutoCAD SHX Text
200.0
AutoCAD SHX Text
225.0
AutoCAD SHX Text
BUS
AutoCAD SHX Text
STOP
AutoCAD SHX Text
BUS
AutoCAD SHX Text
STOP
AutoCAD SHX Text
BUS
AutoCAD SHX Text
STOP
AutoCAD SHX Text
SLOW
AutoCAD SHX Text
SLOW

TL

TLTL

TL

TL

TL

TL

TL

TL

TL

TL

TL

TL

TL

TL

TL

TL

TL

TL

RS

BS

GAS

GAS

GAS

LP

LP

LP

LP

LP

LP

LP

LP

LP

LP

LP

Existing shared

area to remain

Proposed cycleway at

carriageway level

Existing kerbline to remain

Existing uncontrolled

crossing to remain

Proposed toucan crossing

Existing crossing to be

retained

R

a

m

p

E

x

te

n

ts

Ramp Extents

E

Key:

Scheme boundary

Proposed alignment

Existing survey/OS information

Tactile / corduroy paving construction - Refer to

Footways and Paved Areas drawings

B2309009-JAC-1100-DR-1101 to 1105

0.5m cycle segregation island

Proposed Footways and Paved Areas - Refer to

Footways and Paved Areas drawings

B2309009-JAC-1100-DR-1101 to 1105

Proposed Cycleway - Refer to footways and Paved Areas

drawings B2309009-JAC-1100-DR-1101 to 1105

Shared footway - Refer to footways and Paved Areas drawings

B2309009-JAC-1100-DR-1101 to 1105

Visirail as shown on drawings - Refer to Pedestrian guardrail

drawing B2309009-JAC-0400-DR-0402 and as per BCC SD

HW/4.02

Existing / Proposed Lighting column - Refer to Street

Lighting drawings B2309009-JAC-1300-DR-1301 to 1305

Proposed Traffic Sign and pole - Refer to Traffic Sign

drawings B2309009-JAC-1200-DR-1211 to 1215

Traffic Bollard - Refer to Traffic Sign

drawings B2309009-JAC-1200-DR-1211 to 1215

Relocated information board

Existing Edgbaston Road fingerboard sign to be relocated

Proposed bus shelter -Specification to be agreed with

TfWM

Proposed Road Markings - Refer to Road Markings

drawings B2309009-JAC-1200-DR-1201 to 1205

Proposed Traffic Signal - Refer to Traffic Signal drawings

B2309009-JAC-1200-DR-1221 to 1224

Proposed Earthworks and verge

Proposed bin - Broxap Derby Standard Liter Bin - BX45

2550-S (or similar approved) with pyramid top fixed to

permanent position with fixing kit. Colour - Powder coated

RAL 9005 with gold band.

Proposed mini feeder pillar

Earthworks Slope Gradient 1: x

Revision Cloud

x

1

CO

NT

IN

UE

D O

N S

HE

ET

2

CO

NT

IN

UE

D O

N S

HE

ET

4

PERSHORE ROAD - PRIORY ROAD

JUNCTION DETAILED DESIGN

GENERAL ARRANGEMENT

SHEET 3 OF 5

SUITABLE FOR APPROVAL

1:250 @ A1

B2309009

B2309009-JAC-0000-DR-0003 R02

7th Floor, 2 Colmore Square, 38 Colmore Circus

Queensway, Birmingham, B4 6BN

Tel:+44(0)121 237 4000 www.jacobs.com

REPRODUCED FROM ORDNANCE SURVEY MAPS WITH PERMISSION

FROM THE CONTROLLER OF HM STATIONERY OFFICE. CROWN

COPYRIGHT RESERVED. LICENCE No. 0100031673 2018.

S

H

E

E

T

0

1

S

H

E

E

T

0

2

SHEET 03

SHEET 04

SHEET 05

Drawing status

Drawing number

Scale

Client no.

Jacobs No.

Drawing title

DO NOT SCALE

Rev

Project

Client

G

N

W

I

A

R

D

T

U

A

O

A

D

C

P:\B

2309009 - P

ersho

re

R

d- P

rio

ry R

d Jct D

etailed

D

esig

n\0

08 C

AD

D\000

0 G

ene

ral A

rrangem

ent\B

230

900

9-JA

C-00

00-D

R-0

00

3 (S

he

et 3

o

f 5

) R

02

.d

wg

- 3

0/09

/2

02

0 15

:5

3:07

- S

HE

ET

0

3 - G

rice

D

Apprv'dPurpose of revision

Rev Rev. Date Drawn CheckdRev'd

© Copyright 2020 Jacobs U.K. Limited. The concepts and information contained in this document are the property of Jacobs.

Use or copying of this document in whole or in part without the written permission of Jacobs constitutes an infringement of

copyright. Limitation: This drawing has been prepared on behalf of, and for the exclusive use of Jacobs' Client, and is subject

to, and issued in accordance with, the provisions of the contract between Jacobs and the Client. Jacobs accepts no liability or

responsibility whatsoever for, or in respect of, any use of, or reliance upon, this drawing by any third party.

Location Plan - Sheet 3

10m0m 15m5m5m

Scale 1:250

2.5m

12.4m

15.0m

6.3m

2.5m

3.0m

6.7m

6.2m

All site activities shall be carried out in accordance with the Contractor's Construction

Phase Plan and Safe Work Method Statements/Risk Assessments. In addition to the

hazards/risks normally associated with the type of work detailed on this drawing, note

the following:

WORK CAN ONLY BE CARRIED OUT BY SUITABLY TRAINED AND BRIEFED

PERSONNEL.

CONSTRUCTION

1) Working in proximity to live traffic and construction plant.

2) All existing services should be located on site as required by the contractor prior to any construction

works being undertaken.

3) Ensure adequate liaison is undertaken with residents and businesses within the site extents to

ensure safe access / egress arrangements are communicated.

4) Vibration from works operations should be avoided in the vicinity of buildings and utilities.

5) Any works to be undertaken at night should have adequate lighting available, and regulations

regarding noise must be followed.

6) Contact with carcinogenic tar based material.

7) Dust inhalation, noise and excessive vibration.

8) High temperatures from asphalt laying process resulting in burns and fume inhalation.

SAFETY, HEALTH AND ENVIRONMENTAL (SHE) INFORMATION

6.60m

Notes:

1) Drawing to be printed in colour to enable correct viewing of symbols.

2) Do not scale.

3) This drawing to be read in conjunction with all other relevant contract

drawings and documents.

4) The Contractor shall verify the presence and location of all services

before undertaking any work in any area of the site by carrying out a full

non-intrusive survey of the entire site before commencing the works.

5) For cross sections refer to cross section drawings

B2309009-JAC-0000-DR-0041 to 0044 and

B2309009-JAC-0000-DR-0051 to 0065

R02 30/09/20 KEY UPDATED DG MPMP AL

R01 27/05/20 AMENDMENTS MADE DG TSTS AL

R00 20/03/20 SUITABLE FOR APPROVAL BV TS DM AL

AutoCAD SHX Text
100
AutoCAD SHX Text
300.0
AutoCAD SHX Text
325.0
AutoCAD SHX Text
350.0
AutoCAD SHX Text
375.0
AutoCAD SHX Text
400.0
AutoCAD SHX Text
425.0
AutoCAD SHX Text
450.0
AutoCAD SHX Text
SLOW

FH

SVSV

SV

SV

SV

SV

WO

GAS

Existing bus

stop post/flag to

remain

Proposed cycleway at

carriageway level on

existing

Existing bridge trief kerbs and

footway to remain

Edgbasto

n R

oad

Queen's R

ide

R

i

v

e

r

R

e

a

2.0m

2.0m

3.0m

Ramp

Extents

Key:

Scheme boundary

Proposed alignment

Existing survey/OS information

Tactile / corduroy paving construction - Refer to

Footways and Paved Areas drawings

B2309009-JAC-1100-DR-1101 to 1105

0.5m cycle segregation island

Proposed Footways and Paved Areas - Refer to

Footways and Paved Areas drawings

B2309009-JAC-1100-DR-1101 to 1105

Proposed Cycleway - Refer to footways and Paved Areas

drawings B2309009-JAC-1100-DR-1101 to 1105

Shared footway - Refer to footways and Paved Areas drawings

B2309009-JAC-1100-DR-1101 to 1105

Visirail as shown on drawings - Refer to Pedestrian guardrail

drawing B2309009-JAC-0400-DR-0402 and as per BCC SD

HW/4.02

Existing / Proposed Lighting column - Refer to Street

Lighting drawings B2309009-JAC-1300-DR-1301 to 1305

Proposed Traffic Sign and pole - Refer to Traffic Sign

drawings B2309009-JAC-1200-DR-1211 to 1215

Traffic Bollard - Refer to Traffic Sign

drawings B2309009-JAC-1200-DR-1211 to 1215

Relocated information board

Existing Edgbaston Road fingerboard sign to be relocated

Proposed bus shelter -Specification to be agreed with

TfWM

Proposed Road Markings - Refer to Road Markings

drawings B2309009-JAC-1200-DR-1201 to 1205

Proposed Traffic Signal - Refer to Traffic Signal drawings

B2309009-JAC-1200-DR-1221 to 1224

Proposed Earthworks and verge

Proposed bin - Broxap Derby Standard Liter Bin - BX45

2550-S (or similar approved) with pyramid top fixed to

permanent position with fixing kit. Colour - Powder coated

RAL 9005 with gold band.

Proposed mini feeder pillar

Earthworks Slope Gradient 1: x

Revision Cloud

x

1

CO

NT

IN

UE

D O

N S

HE

ET

3

CO

NT

IN

UE

D O

N S

HE

ET

5

PERSHORE ROAD - PRIORY ROAD

JUNCTION DETAILED DESIGN

GENERAL ARRANGEMENT

SHEET 4 OF 5

SUITABLE FOR APPROVAL

1:250 @ A1

B2309009

B2309009-JAC-0000-DR-0004R02

7th Floor, 2 Colmore Square, 38 Colmore Circus

Queensway, Birmingham, B4 6BN

Tel:+44(0)121 237 4000 www.jacobs.com

REPRODUCED FROM ORDNANCE SURVEY MAPS WITH PERMISSION

FROM THE CONTROLLER OF HM STATIONERY OFFICE. CROWN

COPYRIGHT RESERVED. LICENCE No. 0100031673 2018.

S

H

E

E

T

0

1

S

H

E

E

T

0

2

SHEET 03

SHEET 04

SHEET 05

Drawing status

Drawing number

Scale

Client no.

Jacobs No.

Drawing title

DO NOT SCALE

Rev

Project

Client

G

N

W

I

A

R

D

T

U

A

O

A

D

C

P:\B

2309009

- P

ersh

ore R

d- P

riory R

d Jct D

etailed

D

esign\008 C

AD

D\000

0 G

en

eral A

rrangem

ent\B

230

900

9-JA

C-0

00

0-D

R-0

00

4 (S

he

et 4

o

f 5

) R

02

.d

wg

- 3

0/09

/2

02

0 1

5:5

3:4

5 - S

HE

ET

0

4 - G

rice

D

Apprv'dPurpose of revision

Rev Rev. Date Drawn CheckdRev'd

© Copyright 2020 Jacobs U.K. Limited. The concepts and information contained in this document are the property of Jacobs.

Use or copying of this document in whole or in part without the written permission of Jacobs constitutes an infringement of

copyright. Limitation: This drawing has been prepared on behalf of, and for the exclusive use of Jacobs' Client, and is subject

to, and issued in accordance with, the provisions of the contract between Jacobs and the Client. Jacobs accepts no liability or

responsibility whatsoever for, or in respect of, any use of, or reliance upon, this drawing by any third party.

Location Plan - Sheet 4

10m0m 15m5m5m

Scale 1:250

All site activities shall be carried out in accordance with the Contractor's Construction

Phase Plan and Safe Work Method Statements/Risk Assessments. In addition to the

hazards/risks normally associated with the type of work detailed on this drawing, note

the following:

WORK CAN ONLY BE CARRIED OUT BY SUITABLY TRAINED AND BRIEFED

PERSONNEL.

CONSTRUCTION

1) Working in proximity to live traffic and construction plant.

2) All existing services should be located on site as required by the contractor prior to any construction

works being undertaken.

3) Ensure adequate liaison is undertaken with residents and businesses within the site extents to

ensure safe access / egress arrangements are communicated.

4) Vibration from works operations should be avoided in the vicinity of buildings and utilities.

5) Any works to be undertaken at night should have adequate lighting available, and regulations

regarding noise must be followed.

6) Contact with carcinogenic tar based material.

7) Dust inhalation, noise and excessive vibration.

8) High temperatures from asphalt laying process resulting in burns and fume inhalation.

SAFETY, HEALTH AND ENVIRONMENTAL (SHE) INFORMATION

Notes:

1) Drawing to be printed in colour to enable correct viewing of symbols.

2) Do not scale.

3) This drawing to be read in conjunction with all other relevant contract

drawings and documents.

4) The Contractor shall verify the presence and location of all services

before undertaking any work in any area of the site by carrying out a full

non-intrusive survey of the entire site before commencing the works.

5) For cross sections refer to cross section drawings

B2309009-JAC-0000-DR-0041 to 0044 and

B2309009-JAC-0000-DR-0051 to 0065

R02 30/09/20 KEY UPDATED DG MPMP AL

R01 27/05/20 AMENDMENTS MADE DG TSTS AL

R00 20/03/20 SUITABLE FOR APPROVAL BV TS DM AL

AutoCAD SHX Text
FB
AutoCAD SHX Text
Foot
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Path
AutoCAD SHX Text
110.6m
AutoCAD SHX Text
QUEEN'S RIDE
AutoCAD SHX Text
FB
AutoCAD SHX Text
Pond
AutoCAD SHX Text
Boro Const & Ward Bdy
AutoCAD SHX Text
Pond
AutoCAD SHX Text
BUS
AutoCAD SHX Text
STOP
AutoCAD SHX Text
BUS
AutoCAD SHX Text
STOP
AutoCAD SHX Text
SLOW
AutoCAD SHX Text
SLOW
AutoCAD SHX Text
BUS
AutoCAD SHX Text
STOP
AutoCAD SHX Text
475.0
AutoCAD SHX Text
500.0
AutoCAD SHX Text
525.0
AutoCAD SHX Text
550.0
AutoCAD SHX Text
575.0
AutoCAD SHX Text
600.0
AutoCAD SHX Text
625.0

FH

Ramp Extents

E

d

g

b

a

s

to

n

R

o

a

d

C

a

n

n

o

n

H

ill

R

o

a

d

C

a

n

n

o

n

H

ill P

a

rk

Existing toucan

crossing to be

shortened

Existing kerbline to

remain

Proposed cycleway at

carriageway level on

existing westbound

lane

Visirails

Existing street name

plate

E

d

g

b

a

s

t

o

n

R

o

a

d

Existing bus shelter to

remain

Existing bus shelter to

remain

Key:

Scheme boundary

Proposed alignment

Existing survey/OS information

Tactile / corduroy paving construction - Refer to

Footways and Paved Areas drawings

B2309009-JAC-1100-DR-1101 to 1105

0.5m cycle segregation island

Proposed Footways and Paved Areas - Refer to

Footways and Paved Areas drawings

B2309009-JAC-1100-DR-1101 to 1105

Proposed Cycleway - Refer to footways and Paved Areas

drawings B2309009-JAC-1100-DR-1101 to 1105

Shared footway - Refer to footways and Paved Areas drawings

B2309009-JAC-1100-DR-1101 to 1105

Visirail as shown on drawings - Refer to Pedestrian guardrail

drawing B2309009-JAC-0400-DR-0402 and as per BCC SD

HW/4.02

Existing / Proposed Lighting column - Refer to Street

Lighting drawings B2309009-JAC-1300-DR-1301 to 1305

Proposed Traffic Sign and pole - Refer to Traffic Sign

drawings B2309009-JAC-1200-DR-1211 to 1215

Traffic Bollard - Refer to Traffic Sign

drawings B2309009-JAC-1200-DR-1211 to 1215

Relocated information board

Existing Edgbaston Road fingerboard sign to be relocated

Proposed bus shelter -Specification to be agreed with

TfWM

Proposed Road Markings - Refer to Road Markings

drawings B2309009-JAC-1200-DR-1201 to 1205

Proposed Traffic Signal - Refer to Traffic Signal drawings

B2309009-JAC-1200-DR-1221 to 1224

Proposed Earthworks and verge

Proposed bin - Broxap Derby Standard Liter Bin - BX45

2550-S (or similar approved) with pyramid top fixed to

permanent position with fixing kit. Colour - Powder coated

RAL 9005 with gold band.

Proposed mini feeder pillar

Earthworks Slope Gradient 1: x

Revision Cloud

x

1

PERSHORE ROAD - PRIORY ROAD

JUNCTION DETAILED DESIGN

GENERAL ARRANGEMENT

SHEET 5 OF 5

SUITABLE FOR APPROVAL

1:250 @ A1

B2309026

B2309009-JAC-0000-DR-0005 R02

7th Floor, 2 Colmore Square, 38 Colmore Circus

Queensway, Birmingham, B4 6BN

Tel:+44(0)121 237 4000 www.jacobs.com

S

H

E

E

T

0

1

S

H

E

E

T

0

2

SHEET 03

SHEET 04

SHEET 05

Drawing status

Drawing number

Scale

Client no.

Jacobs No.

Drawing title

DO NOT SCALE

Rev

Project

Client

G

N

W

I

A

R

D

T

U

A

O

A

D

C

P:\B

2309009 - P

ersho

re

R

d- P

rio

ry R

d Jct D

etailed

D

esig

n\0

08 C

AD

D\000

0 G

ene

ral A

rrangem

ent\B

230

900

9-JA

C-00

00-D

R-0

00

5 (S

he

et 5

o

f 5

) R

02

.d

wg

- 3

0/09

/2

02

0 1

6:1

9:0

6 - S

HE

ET

0

5 - G

rice

D

Apprv'dPurpose of revision

Rev Rev. Date Drawn CheckdRev'd

© Copyright 2020 Jacobs U.K. Limited. The concepts and information contained in this document are the property of Jacobs.

Use or copying of this document in whole or in part without the written permission of Jacobs constitutes an infringement of

copyright. Limitation: This drawing has been prepared on behalf of, and for the exclusive use of Jacobs' Client, and is subject

to, and issued in accordance with, the provisions of the contract between Jacobs and the Client. Jacobs accepts no liability or

responsibility whatsoever for, or in respect of, any use of, or reliance upon, this drawing by any third party.

CO

NT

IN

UE

D O

N S

HE

ET

4

REPRODUCED FROM ORDNANCE SURVEY MAPS WITH PERMISSION

FROM THE CONTROLLER OF HM STATIONERY OFFICE. CROWN

COPYRIGHT RESERVED. LICENCE No. 0100031673 2018.

CO

NT

IN

UE

D O

N IN

SE

T B

CO

NT

IN

UE

D A

BO

VE

INSET B

3.0m

Location Plan - Sheet 5

10m0m 15m5m5m

Scale 1:250

All site activities shall be carried out in accordance with the Contractor's Construction

Phase Plan and Safe Work Method Statements/Risk Assessments. In addition to the

hazards/risks normally associated with the type of work detailed on this drawing, note

the following:

WORK CAN ONLY BE CARRIED OUT BY SUITABLY TRAINED AND BRIEFED

PERSONNEL.

CONSTRUCTION

1) Working in proximity to live traffic and construction plant.

2) All existing services should be located on site as required by the contractor prior to any construction

works being undertaken.

3) Ensure adequate liaison is undertaken with residents and businesses within the site extents to

ensure safe access / egress arrangements are communicated.

4) Vibration from works operations should be avoided in the vicinity of buildings and utilities.

5) Any works to be undertaken at night should have adequate lighting available, and regulations

regarding noise must be followed.

6) Contact with carcinogenic tar based material.

7) Dust inhalation, noise and excessive vibration.

8) High temperatures from asphalt laying process resulting in burns and fume inhalation.

SAFETY, HEALTH AND ENVIRONMENTAL (SHE) INFORMATION

Notes:

1) Drawing to be printed in colour to enable correct viewing of symbols.

2) Do not scale.

3) This drawing to be read in conjunction with all other relevant contract

drawings and documents.

4) The Contractor shall verify the presence and location of all services

before undertaking any work in any area of the site by carrying out a full

non-intrusive survey of the entire site before commencing the works.

5) For cross sections refer to cross section drawings

B2309009-JAC-0000-DR-0041 to 0044 and

B2309009-JAC-0000-DR-0051 to 0065

R02 30/09/20

SHARED HATCH AND KEY UPDATED, HAZARD

PAVING ADDED TO END OF SCHEME, ROAD PLATE

LEADER ADDED

DG MPMP AL

R01 27/05/20 AMENDMENTS MADE DG TSTS AL

R00 20/03/20 SUITABLE FOR APPROVAL BV TS DM AL

AutoCAD SHX Text
900
AutoCAD SHX Text
Pond
AutoCAD SHX Text
Pond
AutoCAD SHX Text
650.0
AutoCAD SHX Text
675.0
AutoCAD SHX Text
700.0
AutoCAD SHX Text
725.0
AutoCAD SHX Text
750.0
AutoCAD SHX Text
775.0
AutoCAD SHX Text
SLOW
AutoCAD SHX Text
BUS
AutoCAD SHX Text
STOP
AutoCAD SHX Text
BUS
AutoCAD SHX Text
STOP