«A la carte» Programmedonar.messe.de/.../ce-t-tsi-inverter-a-la-carte-eng... · TSI Bravo Shelf...

8
«A la carte» Programme The complete modular AC/AC and DC/AC converter range up to 225kVA AC output power solutions Each»module»has»AC»and»DC»input»without»need»of»a»static»switch Dynamic»source»transfer»0mS»from»AC»to»DC»and»vice»versa Single»point»of»failure»elimination»(no»need»of»external»static»switch) Evolutive»architecture»A+B»without»need»of»external»static»switch High»effi » » ciency»up»to»96%»in»normal»operation η +

Transcript of «A la carte» Programmedonar.messe.de/.../ce-t-tsi-inverter-a-la-carte-eng... · TSI Bravo Shelf...

Page 1: «A la carte» Programmedonar.messe.de/.../ce-t-tsi-inverter-a-la-carte-eng... · TSI Bravo Shelf and TSI Bravo modules Phase 1 TSI Bravo Shelf and TSI Bravo modules Phase 2 TSI Bravo

«Alacarte»ProgrammeThecompletemodularAC/ACandDC/ACconverterrangeupto225kVAACoutputpowersolutions

Each»module»has»AC»and»DC»input»without»need»of»a»static»switch

Dynamic»source»transfer»0mS»from»AC»to»DC»and»vice»versa

Single»point»of»failure»elimination»(no»need»of»external»static»switch)

Evolutive»architecture»A+B»without»need»of»external»static»switch

High»effi»»ciency»up»to»96%»in»normal»operationη+

TSI_ALACARTE_CET_POUR BROCHURE.indd 2 21/02/11 20:15

Page 2: «A la carte» Programmedonar.messe.de/.../ce-t-tsi-inverter-a-la-carte-eng... · TSI Bravo Shelf and TSI Bravo modules Phase 1 TSI Bravo Shelf and TSI Bravo modules Phase 2 TSI Bravo

TSI Inverter system schematic

A & B architecture with TSI Module

ACOUT bulk bkr

TSI Modules

Battery

AC OutputDistribution

(Optional)

(Optional)

(Optional)

SNMP

DISPLAY

TSS

AC Input bkr(Optional)

Manual By-pass Switch(Optional)

AC

Inp

ut

DEG

LOAD

Feed A Feed B

A1 B1

An Bn

DEG

LOAD

TechnologyinactionTSIisanadvancedstepinDC/ACmodularconvertertechnology.Offeringhigherpower,higherefficiency,loweroperationcostandhavingapositivecarbonimpact.

Intoday’sfastmovingbusinessandclimatechanges,organisationsneedanticipation;1.Topreventdowntime,ensurethecontinuityofserviceandmaximizerevenue2.ToreduceOPEXandoptimizeCAPEX3.Totakeintoconsiderationenvironmentalfactor

»» »The»«A»la»carte»»programme»is»structured»around»a»complete»module»range»of»500VA,»750VA,»1500VA,»2500VA»output»power

»» »Each»module»is»equipped»with»dual»AC»and»DC»input»(except»500VA)»» A»dynamic»source»transfer»garantees»switching»from»AC»to»DC»with»

» 0»mS»transfer»time»and»vice»versa.»»» TSI»systems»can»operate»in»2»working»mode»» »EPCmode

While»AC»input»mains»is»present»a»double»conversion»AC/DC»and»DC/AC»with»96%»effi»»ciency»supplies»a»pure»stabilized»AC»output»voltage.»In»case»of»AC»input»failure»a»dynamic»source»transfer»ensures»the»transition»of»power»to»the»DC»battery»without»interruption.»

» Onlinemode»DC»input»battery»is»the»primary»source»and»converted»into»a»pure»stabilized»»AC»ouput.»In»case»of»battery»or»DC»failure»the»AC»load»will»be»transfered»on»AC»input»source

»» »η+ EPC»mode»has»up»to»96%»effi»»ciency»and»reduce»signifi»cantly»the»losses»compared»to»conventional»DC/AC»inverter.»It»also»has»a»positive»impact»on»environnement»and»reduces»signifi»cantly»the»operation»costs.»

»Applications&advantages

»» »The»TSI»technology»is»ideal»in»ICT»and»Industry»installations»where»DC»batteries»are»present»and»critical»applications»need»a»reliable»AC»output»power»with»long»battery»back»up»time»up»to»225kVA»single»or»3»phases.

»» »By»adding»Modular»battery»charger»we»can»build»Modular»UPS»with»long»battery»back»up»time.

»» »Possibility»to»realize»A+B»installation»without»static»switches.»» »Elimination»of»external»static»switch»and»rectifi»er»are»sized»only»to»

charge»battery.»» »Expandable»system»up»to»225kVA»and»modular»architecture.»» »AC»mains»fi»ltering»(unity»power»factor»ACin).»»» AC»output»stabilized»at»230VAC»with»ACin»from»150VAC»to»265VAC.»» »Simplifi»ed»installation»and»commissioning.

TSI_ALACARTE_CET_POUR BROCHURE.indd 3 21/02/11 20:15

TSI programme «A La Carte» off ers a unique confi guration tool to customize the TSI solution ready to use to secure the power supply of your criticalACloadapplication.

TechnologyinactionTSIisanadvancedstepinDC/ACmodularconvertertechnology.Offeringhigherpower,higherefficiency,loweroperationcostandhavingapositivecarbonimpact.

Weoff ermorethenjustanInverterOurcompletesolutioncabinetsaredesignedtoprocureeasyinstallation,easycustomerconnection,andreduceinstallationcosts.

»» »Easy»installation»:»terminations»and»connections»are»located»in»one»«cold»zone»»area»providing»easy»cable»access,»fi»xing»and»termination»point»for»AC»input,»DC»input,»AC»output»and»alarms»connections.

»» Tested»&»certifi»ed»:»All»CE+T»Power»systems»have»been»tested»for»vibrations,»high»operating»T°»and»EMC»to»grant»excellent»operation»in»severe»environment.

12

H

G

F

E

D

C

B

A

J

K

L

M

N

P

Q

R

A

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

1110987654321 13 14 15 16 17 18 19 20 21 22 23 24

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Assem6

XXX

XXX

XXX

XXXXXX

XXX

XXX

XXX

WEIGHT:

A0

SHEET 2 OF 2SCALE:1:2

DWG NO.

TITLE:

REVISIONDO NOT SCALE DRAWING

MATERIAL:

DATESIGNATURENAME

DEBUR AND BREAK SHARP EDGES

FINISH:UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:

Q.A

MFG

APPV'D

CHK'D

DRAWN

Termination Box

AC distribution line (Optional)

Manual By Pass (Optional)

DC input protectionBreaker (Optional)

TSI Bravo Shelf and TSI Bravo modulesPhase 1

TSI Bravo Shelf and TSI Bravo modulesPhase 2

TSI Bravo Shelf and TSI Bravo modulesPhase 3

Cabinet Footprint 600x600mm (WxD)

CANDIS Display & TCP-IP (Optional)

75kVA system 3 phases in CE+T Power cabinet600x600x2100 mm (WxDxH)

TSI_ALACARTE_CET_POUR BROCHURE.indd 4 21/02/11 20:15

Page 3: «A la carte» Programmedonar.messe.de/.../ce-t-tsi-inverter-a-la-carte-eng... · TSI Bravo Shelf and TSI Bravo modules Phase 1 TSI Bravo Shelf and TSI Bravo modules Phase 2 TSI Bravo

TSI Inverter system schematic

A & B architecture with TSI Module

ACOUT bulk bkr

TSI Modules

Battery

AC OutputDistribution

(Optional)

(Optional)

(Optional)

SNMP

DISPLAY

TSS

AC Input bkr(Optional)

Manual By-pass Switch(Optional)

AC

Inp

ut

DEG

LOAD

Feed A Feed B

A1 B1

An Bn

DEG

LOAD

TechnologyinactionTSIisanadvancedstepinDC/ACmodularconvertertechnology.Offeringhigherpower,higherefficiency,loweroperationcostandhavingapositivecarbonimpact.

Intoday’sfastmovingbusinessandclimatechanges,organisationsneedanticipation;1.Topreventdowntime,ensurethecontinuityofserviceandmaximizerevenue2.ToreduceOPEXandoptimizeCAPEX3.Totakeintoconsiderationenvironmentalfactor

»» »The»«A»la»carte»»programme»is»structured»around»a»complete»module»range»of»500VA,»750VA,»1500VA,»2500VA»output»power

»» »Each»module»is»equipped»with»dual»AC»and»DC»input»(except»500VA)»» A»dynamic»source»transfer»garantees»switching»from»AC»to»DC»with»

» 0»mS»transfer»time»and»vice»versa.»»» TSI»systems»can»operate»in»2»working»mode»» »EPCmode

While»AC»input»mains»is»present»a»double»conversion»AC/DC»and»DC/AC»with»96%»effi»»ciency»supplies»a»pure»stabilized»AC»output»voltage.»In»case»of»AC»input»failure»a»dynamic»source»transfer»ensures»the»transition»of»power»to»the»DC»battery»without»interruption.»

» Onlinemode»DC»input»battery»is»the»primary»source»and»converted»into»a»pure»stabilized»»AC»ouput.»In»case»of»battery»or»DC»failure»the»AC»load»will»be»transfered»on»AC»input»source

»» »η+ EPC»mode»has»up»to»96%»effi»»ciency»and»reduce»signifi»cantly»the»losses»compared»to»conventional»DC/AC»inverter.»It»also»has»a»positive»impact»on»environnement»and»reduces»signifi»cantly»the»operation»costs.»

»Applications&advantages

»» »The»TSI»technology»is»ideal»in»ICT»and»Industry»installations»where»DC»batteries»are»present»and»critical»applications»need»a»reliable»AC»output»power»with»long»battery»back»up»time»up»to»225kVA»single»or»3»phases.

»» »By»adding»Modular»battery»charger»we»can»build»Modular»UPS»with»long»battery»back»up»time.

»» »Possibility»to»realize»A+B»installation»without»static»switches.»» »Elimination»of»external»static»switch»and»rectifi»er»are»sized»only»to»

charge»battery.»» »Expandable»system»up»to»225kVA»and»modular»architecture.»» »AC»mains»fi»ltering»(unity»power»factor»ACin).»»» AC»output»stabilized»at»230VAC»with»ACin»from»150VAC»to»265VAC.»» »Simplifi»ed»installation»and»commissioning.

TSI_ALACARTE_CET_POUR BROCHURE.indd 3 21/02/11 20:15

TSI programme «A La Carte» off ers a unique confi guration tool to customize the TSI solution ready to use to secure the power supply of your criticalACloadapplication.

TechnologyinactionTSIisanadvancedstepinDC/ACmodularconvertertechnology.Offeringhigherpower,higherefficiency,loweroperationcostandhavingapositivecarbonimpact.

Weoff ermorethenjustanInverterOurcompletesolutioncabinetsaredesignedtoprocureeasyinstallation,easycustomerconnection,andreduceinstallationcosts.

»» »Easy»installation»:»terminations»and»connections»are»located»in»one»«cold»zone»»area»providing»easy»cable»access,»fi»xing»and»termination»point»for»AC»input,»DC»input,»AC»output»and»alarms»connections.

»» Tested»&»certifi»ed»:»All»CE+T»Power»systems»have»been»tested»for»vibrations,»high»operating»T°»and»EMC»to»grant»excellent»operation»in»severe»environment.

12

H

G

F

E

D

C

B

A

J

K

L

M

N

P

Q

R

A

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

1110987654321 13 14 15 16 17 18 19 20 21 22 23 24

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Assem6

XXX

XXX

XXX

XXXXXX

XXX

XXX

XXX

WEIGHT:

A0

SHEET 2 OF 2SCALE:1:2

DWG NO.

TITLE:

REVISIONDO NOT SCALE DRAWING

MATERIAL:

DATESIGNATURENAME

DEBUR AND BREAK SHARP EDGES

FINISH:UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:

Q.A

MFG

APPV'D

CHK'D

DRAWN

Termination Box

AC distribution line (Optional)

Manual By Pass (Optional)

DC input protectionBreaker (Optional)

TSI Bravo Shelf and TSI Bravo modulesPhase 1

TSI Bravo Shelf and TSI Bravo modulesPhase 2

TSI Bravo Shelf and TSI Bravo modulesPhase 3

Cabinet Footprint 600x600mm (WxD)

CANDIS Display & TCP-IP (Optional)

75kVA system 3 phases in CE+T Power cabinet600x600x2100 mm (WxDxH)

TSI_ALACARTE_CET_POUR BROCHURE.indd 4 21/02/11 20:15

Page 4: «A la carte» Programmedonar.messe.de/.../ce-t-tsi-inverter-a-la-carte-eng... · TSI Bravo Shelf and TSI Bravo modules Phase 1 TSI Bravo Shelf and TSI Bravo modules Phase 2 TSI Bravo

THIRD ANGLE PROJECTION

12

H

G

F

E

D

C

B

A

J

K

L

M

N

P

Q

R

A

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

1110

98

76

54

32

1

1314

1516

1718

1920

2122

2324

12

34

56

78

910

1112

1314

1516

1718

1920 Assem6

XXX

XXX

XXX

XXXXXX

XXX

XXX

XXX

WEIGHT: A0

SHEET 1 OF 1

SCALE:1:2

DWG NO.

TITLE:

REVISION

DO NOT SCALE DRAWING

MATERIAL:

DATESIGNATURE

NAME

DEBUR AND BREAK SHARP EDGES

FINISH:UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:

Q.A

MFG

APPV'D

CHK'D

DRAWN

»ACoutput

»» Bulk»on»terminal»or»breaker»(option).

»» »AC»distribution»line.»Up»to»20bkr»1»pole,»10bkr»2»poles,»5bkr»3»poles»to»be»installed»live»and»safe.»Max»40A»per»breaker.

»» Single»phase»or»3»phases.

Theterminationbox isthekeysuccess inthe«ALaCarte»programmecoveringallaspecttoprovideeasy installation,commissioningandtomaximizesystemoperationwhilereducingCAPEXandOPEX.

»DCinput

»» COMMON»DC»:»each»module»can»be»protected»with»breaker»(option).

»» INDIVIDUAL»DC»:»with»or»without»breaker»(option).

»ACinput

»» Single»phase»or»3»phases.

»» Bulk»on»terminal.

»» Bulk»on»breaker»(option)

»» »3»wires»(L1,»N,»PE)»for»single»phase»and»5»wires»(L1,»L2,»L3,»N,»PE)»for»3»phases.

»ToporBottomcabling

»» Top»cabling»by»default,»all»cables»easily»fixed»with»tie»rap.

»» Bottom»cabling»on»request.

WeoffermorethenjustanInverterOurcompletesolutioncabinetsaredesignedtoprocureeasyinstallation,easycustomerconnection,andreduceinstallationcosts.

MakeyourideasgofurtherSelectthepoweryouneed,andbuildyoursolutionprogressively.

TSI_ALACARTE_CET_POUR BROCHURE.indd 5 21/02/11 20:15

THIRD ANGLE PROJECTION

12

H

G

F

E

D

C

B

A

J

K

L

M

N

P

Q

R

A

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

1110987654321 13 14 15 16 17 18 19 20 21 22 23 24

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Assem6

XXX

XXX

XXX

XXXXXX

XXX

XXX

XXX

WEIGHT:

A0

SHEET 1 OF 1SCALE:1:2

DWG NO.

TITLE:

REVISIONDO NOT SCALE DRAWING

MATERIAL:

DATESIGNATURENAME

DEBUR AND BREAK SHARP EDGES

FINISH:UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:

Q.A

MFG

APPV'D

CHK'D

DRAWN

»Manualbypass

»» 20kVA,»40kVA,»60kVA,»80kVA»single»phase.

»» 30kVA,»75kVA»3»phases.

»» »Make»before»break»manual»by-pass»switch»only»needed»for»service»maintenance.

»Alarmterminal

»» Dry»changeover»contact»NO,»NC,»C.

-»Minor»:»minor»event»in»system.-»Major»:»major»event»in»system.-»Aux»:»user»confi»gurable»contact.

»» Contact»rating»:»0,5A»/»30VDC.

»Monitoring

Monitoring

»» 3»LEDS»local.

»» »USB»com»port»for»parameter»setting»and»to»consult»system»information»

»» »Optional»MODBUS»/»CANBUS»communication»with»other»monitoring»equipment

CANDIS display & CANDIS TCP-IP(option)

»» CANDIS»DisplayProvides»all»system»input»&»output»measurementsSingle»or»3»phases»display.Scroll»menu»push»button.

»» CANDIS TCP/IP-SNMPOff»ers»remote»access»through»Ethernet,»Web»Explorer,»SNMP»protocol.

CANDIS TCP/IP Web user Interface example.

MakeyourideasgofurtherSelectthepoweryouneed,andbuildyoursolutionprogressively.

Weallhavetowin

TSI_ALACARTE_CET_POUR BROCHURE.indd 6 21/02/11 20:15

Page 5: «A la carte» Programmedonar.messe.de/.../ce-t-tsi-inverter-a-la-carte-eng... · TSI Bravo Shelf and TSI Bravo modules Phase 1 TSI Bravo Shelf and TSI Bravo modules Phase 2 TSI Bravo

THIRD ANGLE PROJECTION

12

H

G

F

E

D

C

B

A

J

K

L

M

N

P

Q

R

A

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

1110

98

76

54

32

1

1314

1516

1718

1920

2122

2324

12

34

56

78

910

1112

1314

1516

1718

1920 Assem6

XXX

XXX

XXX

XXXXXX

XXX

XXX

XXX

WEIGHT: A0

SHEET 1 OF 1

SCALE:1:2

DWG NO.

TITLE:

REVISION

DO NOT SCALE DRAWING

MATERIAL:

DATESIGNATURE

NAME

DEBUR AND BREAK SHARP EDGES

FINISH:UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:

Q.A

MFG

APPV'D

CHK'D

DRAWN

»ACoutput

»» Bulk»on»terminal»or»breaker»(option).

»» »AC»distribution»line.»Up»to»20bkr»1»pole,»10bkr»2»poles,»5bkr»3»poles»to»be»installed»live»and»safe.»Max»40A»per»breaker.

»» Single»phase»or»3»phases.

Theterminationbox isthekeysuccess inthe«ALaCarte»programmecoveringallaspecttoprovideeasy installation,commissioningandtomaximizesystemoperationwhilereducingCAPEXandOPEX.

»DCinput

»» COMMON»DC»:»each»module»can»be»protected»with»breaker»(option).

»» INDIVIDUAL»DC»:»with»or»without»breaker»(option).

»ACinput

»» Single»phase»or»3»phases.

»» Bulk»on»terminal.

»» Bulk»on»breaker»(option)

»» »3»wires»(L1,»N,»PE)»for»single»phase»and»5»wires»(L1,»L2,»L3,»N,»PE)»for»3»phases.

»ToporBottomcabling

»» Top»cabling»by»default,»all»cables»easily»fixed»with»tie»rap.

»» Bottom»cabling»on»request.

WeoffermorethenjustanInverterOurcompletesolutioncabinetsaredesignedtoprocureeasyinstallation,easycustomerconnection,andreduceinstallationcosts.

MakeyourideasgofurtherSelectthepoweryouneed,andbuildyoursolutionprogressively.

TSI_ALACARTE_CET_POUR BROCHURE.indd 5 21/02/11 20:15

THIRD ANGLE PROJECTION

12

H

G

F

E

D

C

B

A

J

K

L

M

N

P

Q

R

A

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

1110987654321 13 14 15 16 17 18 19 20 21 22 23 24

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Assem6

XXX

XXX

XXX

XXXXXX

XXX

XXX

XXX

WEIGHT:

A0

SHEET 1 OF 1SCALE:1:2

DWG NO.

TITLE:

REVISIONDO NOT SCALE DRAWING

MATERIAL:

DATESIGNATURENAME

DEBUR AND BREAK SHARP EDGES

FINISH:UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:

Q.A

MFG

APPV'D

CHK'D

DRAWN

»Manualbypass

»» 20kVA,»40kVA,»60kVA,»80kVA»single»phase.

»» 30kVA,»75kVA»3»phases.

»» »Make»before»break»manual»by-pass»switch»only»needed»for»service»maintenance.

»Alarmterminal

»» Dry»changeover»contact»NO,»NC,»C.

-»Minor»:»minor»event»in»system.-»Major»:»major»event»in»system.-»Aux»:»user»confi»gurable»contact.

»» Contact»rating»:»0,5A»/»30VDC.

»Monitoring

Monitoring

»» 3»LEDS»local.

»» »USB»com»port»for»parameter»setting»and»to»consult»system»information»

»» »Optional»MODBUS»/»CANBUS»communication»with»other»monitoring»equipment

CANDIS display & CANDIS TCP-IP(option)

»» CANDIS»DisplayProvides»all»system»input»&»output»measurementsSingle»or»3»phases»display.Scroll»menu»push»button.

»» CANDIS TCP/IP-SNMPOff»ers»remote»access»through»Ethernet,»Web»Explorer,»SNMP»protocol.

CANDIS TCP/IP Web user Interface example.

MakeyourideasgofurtherSelectthepoweryouneed,andbuildyoursolutionprogressively.

Weallhavetowin

TSI_ALACARTE_CET_POUR BROCHURE.indd 6 21/02/11 20:15

Page 6: «A la carte» Programmedonar.messe.de/.../ce-t-tsi-inverter-a-la-carte-eng... · TSI Bravo Shelf and TSI Bravo modules Phase 1 TSI Bravo Shelf and TSI Bravo modules Phase 2 TSI Bravo

Modulerange

»» Output»500VA/400W»up»to»65°C»operation»full»power

»» Ideal»for»300mm»depth»enclosure

»» »η+ Effi»»ciency»89%»DC/AC

»» 230VAC»output»voltage

»» 48VDC»input»voltage

»VEDAModule

»» 750VA/525W»output»power»up»to»50°C»operation»full»power.

»» »η+ Effi»»ciency»93%»in»EPC»mode,»90%»DC/AC»mode

»» 230VAC»output»voltage

»» 48VDC»input»voltage

»NOVAModule

»» 1500VA/1200W»output»power»up»to»50°C»operation»full»power

»» »η+ Effi»»ciency»94%»in»EPC»mode,»90%»DC/AC»mode

»» 230VAC»and»120VAC»output»voltage

»» 48VDC»input»voltage

»MEDIAModule

»» 2500VA/2000W»output»power

»» »η+ Effi»»ciency»96%»in»EPC»mode,»91%»DC/AC»mode

»» 230VAC»and»120VAC»voltage

»» »48VDC,»60VDC,»110VDC,»24VDC»(1500VA/1200W)»input»voltage

»BRAVOModule

The«AlaCarte»programmeisbasedonacompletemodulerange.Weoff ersolutionsfrom500VAupto225kVA.

TSI_ALACARTE_CET_POUR BROCHURE.indd 7 21/02/11 20:15

«Alacarte»OverviewProgrammePleaseconsultCE+TPowerSalesforanycustomisedsolutionyouneed

»«Alacarte»48VDC,60VDC,110VDC

»Largesystemsupto225kVA

»» »Our» systems» can» be» extended» to» large» 3» phases» installations» with» up» to»3x75kVA»systems»to»deliver»an»output»power»of»225kVA.

»» »3» systems,» up» to» 75kVA» each,» are» synchronized» to» provide» a» reliable» pure»AC»output»power»for»critical»applications.

The“ALaCarte”rangeisintegratedin19inchesstandardcabinet600x600mmHeightcanbe1100,1800,2130mmdependingonpoweranddistributionline.DC input

Votage 48VDC 60VDC, 110VDC

DC output Votage 220/230VAC 3x400VAC 120VAC 120/240VAC 3x208VAC 220/230VAC 3x400VAC

Power kVA

Nbr Module

Nbr Rack

Nbr Module

Nbr Rack

Nbr Module

Nbr Rack

Nbr Module

Nbr Rack

Nbr Module

Nbr Rack

Nbr Module

Nbr Rack

Nbr Module

Nbr Rack

3 4xNOVA2xBRAVO

1xNOVA1xBRAVO

6xNOVA3xBRAVO

3xNOVA3xBRAVO

2xMEDIA2xBRAVO

1xMEDIA1xBRAVO

2xMEDIA2xBRAVO

2xMEDIA2xBRAVO

3xMEDIA3xBRAVO

3xMEDIA3xBRAVO 2xBRAVO 1xBRAVO 3xBRAVO 3xBRAVO

5 7xNOVA2xBRAVO

2xNOVA1xBRAVO

9xNOVA3xBRAVO

6xNOVA3xBRAVO

4xMEDIA2xBRAVO

1xMEDIA1xBRAVO

4xMEDIA2xBRAVO

2xMEDIA2xBRAVO

6xMEDIA3xBRAVO

3xMEDIA3xBRAVO 2xBRAVO 1xBRAVO 3xBRAVO 3xBRAVO

6 8xNOVA3xBRAVO

2xNOVA1xBRAVO

9xNOVA3xBRAVO

6xNOVA3xBRAVO

4xMEDIA3xBRAVO

1xMEDIA1xBRAVO

4xMEDIA4xBRAVO

2xMEDIA2xBRAVO

6xMEDIA3xBRAVO

3xMEDIA3xBRAVO 3xBRAVO 1xBRAVO 3xBRAVO 3xBRAVO

9 12xNOVA4xBRAVO

3xNOVA1xBRAVO

12xNOVA6xBRAVO

3xNOVA3xBRAVO

6xMEDIA4xBRAVO

2xMEDIA1xBRAVO

6xMEDIA4xBRAVO

2xMEDIA2xBRAVO

6xMEDIA6xBRAVO

3xMEDIA3xBRAVO 4xBRAVO 1xBRAVO 6xBRAVO 3xBRAVO

12 16xNOVA5xBRAVO

4xNOVA2xBRAVO

18xNOVA6xBRAVO

6xNOVA3xBRAVO

8xMEDIA5xBRAVO

2xMEDIA2xBRAVO

8xMEDIA6xBRAVO

2xMEDIA2xBRAVO

9xMEDIA6xBRAVO

3xMEDIA3xBRAVO 5xBRAVO 2xBRAVO 6xBRAVO 3xBRAVO

15 20xNOVA6xBRAVO

5xNOVA2xBRAVO

21xNOVA6xBRAVO

6xNOVA3xBRAVO

10xMEDIA6xBRAVO

3xMEDIA2xBRAVO

10xMEDIA6xBRAVO

4xMEDIA2xBRAVO

12xMEDIA6xBRAVO

3xMEDIA2xBRAVO 6xBRAVO 2xBRAVO 6xBRAVO 3xBRAVO

18 24xNOVA8xBRAVO

6xNOVA2xBRAVO

24xNOVA9xBRAVO

6xNOVA3xBRAVO

12xMEDIA8xBRAVO

3xMEDIA2xBRAVO

12xMEDIA8xBRAVO

4xMEDIA2xBRAVO

12xMEDIA9xBRAVO

3xMEDIA3xBRAVO 8xBRAVO 2xBRAVO 9xBRAVO 3xBRAVO

20 8xBRAVO 2xBRAVO 9xBRAVO 3xBRAVO 8xBRAVO 2xBRAVO 8xBRAVO 2xBRAVO 9xBRAVO 3xBRAVO 8xBRAVO 2xBRAVO 9xBRAVO 3xBRAVO

24 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 10xBRAVO 4xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO

30 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 4xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO

40 16xBRAVO 4xBRAVO 18xBRAVO 6xBRAVO 16xBRAVO 4xBRAVO 16xBRAVO 4xBRAVO 18xBRAVO 6xBRAVO 16xBRAVO 4xBRAVO 18xBRAVO 6xBRAVO

50 20xBRAVO 5xBRAVO 20xBRAVO 6xBRAVO 20xBRAVO 5xBRAVO 20xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 20xBRAVO 5xBRAVO 24xBRAVO 6xBRAVO

60 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO

70 28xBRAVO 7xBRAVO 30xBRAVO 9xBRAVO 28xBRAVO 7xBRAVO 28xBRAVO 8xBRAVO 30xBRAVO 9xBRAVO 28xBRAVO 7xBRAVO 30xBRAVO 9xBRAVO

75 30xBRAVO 8xBRAVO 30xBRAVO 9xBRAVO 30xBRAVO 8xBRAVO 30xBRAVO 8xBRAVO 30xBRAVO 9xBRAVO 30xBRAVO 8xBRAVO 30xBRAVO 9xBRAVO

80 32xBRAVO 9xBRAVO NA NA 32xBRAVO 9xBRAVO 32xBRAVO 8xBRAVO NA NA 32xBRAVO 9xBRAVO NA NA

TSI_ALACARTE_CET_POUR BROCHURE.indd 8 21/02/11 20:15

Page 7: «A la carte» Programmedonar.messe.de/.../ce-t-tsi-inverter-a-la-carte-eng... · TSI Bravo Shelf and TSI Bravo modules Phase 1 TSI Bravo Shelf and TSI Bravo modules Phase 2 TSI Bravo

Modulerange

»» Output»500VA/400W»up»to»65°C»operation»full»power

»» Ideal»for»300mm»depth»enclosure

»» »η+ Effi»»ciency»89%»DC/AC

»» 230VAC»output»voltage

»» 48VDC»input»voltage

»VEDAModule

»» 750VA/525W»output»power»up»to»50°C»operation»full»power.

»» »η+ Effi»»ciency»93%»in»EPC»mode,»90%»DC/AC»mode

»» 230VAC»output»voltage

»» 48VDC»input»voltage

»NOVAModule

»» 1500VA/1200W»output»power»up»to»50°C»operation»full»power

»» »η+ Effi»»ciency»94%»in»EPC»mode,»90%»DC/AC»mode

»» 230VAC»and»120VAC»output»voltage

»» 48VDC»input»voltage

»MEDIAModule

»» 2500VA/2000W»output»power

»» »η+ Effi»»ciency»96%»in»EPC»mode,»91%»DC/AC»mode

»» 230VAC»and»120VAC»voltage

»» »48VDC,»60VDC,»110VDC,»24VDC»(1500VA/1200W)»input»voltage

»BRAVOModule

The«AlaCarte»programmeisbasedonacompletemodulerange.Weoff ersolutionsfrom500VAupto225kVA.

TSI_ALACARTE_CET_POUR BROCHURE.indd 7 21/02/11 20:15

«Alacarte»OverviewProgrammePleaseconsultCE+TPowerSalesforanycustomisedsolutionyouneed

»«Alacarte»48VDC,60VDC,110VDC

»Largesystemsupto225kVA

»» »Our» systems» can» be» extended» to» large» 3» phases» installations» with» up» to»3x75kVA»systems»to»deliver»an»output»power»of»225kVA.

»» »3» systems,» up» to» 75kVA» each,» are» synchronized» to» provide» a» reliable» pure»AC»output»power»for»critical»applications.

The“ALaCarte”rangeisintegratedin19inchesstandardcabinet600x600mmHeightcanbe1100,1800,2130mmdependingonpoweranddistributionline.DC input

Votage 48VDC 60VDC, 110VDC

DC output Votage 220/230VAC 3x400VAC 120VAC 120/240VAC 3x208VAC 220/230VAC 3x400VAC

Power kVA

Nbr Module

Nbr Rack

Nbr Module

Nbr Rack

Nbr Module

Nbr Rack

Nbr Module

Nbr Rack

Nbr Module

Nbr Rack

Nbr Module

Nbr Rack

Nbr Module

Nbr Rack

3 4xNOVA2xBRAVO

1xNOVA1xBRAVO

6xNOVA3xBRAVO

3xNOVA3xBRAVO

2xMEDIA2xBRAVO

1xMEDIA1xBRAVO

2xMEDIA2xBRAVO

2xMEDIA2xBRAVO

3xMEDIA3xBRAVO

3xMEDIA3xBRAVO 2xBRAVO 1xBRAVO 3xBRAVO 3xBRAVO

5 7xNOVA2xBRAVO

2xNOVA1xBRAVO

9xNOVA3xBRAVO

6xNOVA3xBRAVO

4xMEDIA2xBRAVO

1xMEDIA1xBRAVO

4xMEDIA2xBRAVO

2xMEDIA2xBRAVO

6xMEDIA3xBRAVO

3xMEDIA3xBRAVO 2xBRAVO 1xBRAVO 3xBRAVO 3xBRAVO

6 8xNOVA3xBRAVO

2xNOVA1xBRAVO

9xNOVA3xBRAVO

6xNOVA3xBRAVO

4xMEDIA3xBRAVO

1xMEDIA1xBRAVO

4xMEDIA4xBRAVO

2xMEDIA2xBRAVO

6xMEDIA3xBRAVO

3xMEDIA3xBRAVO 3xBRAVO 1xBRAVO 3xBRAVO 3xBRAVO

9 12xNOVA4xBRAVO

3xNOVA1xBRAVO

12xNOVA6xBRAVO

3xNOVA3xBRAVO

6xMEDIA4xBRAVO

2xMEDIA1xBRAVO

6xMEDIA4xBRAVO

2xMEDIA2xBRAVO

6xMEDIA6xBRAVO

3xMEDIA3xBRAVO 4xBRAVO 1xBRAVO 6xBRAVO 3xBRAVO

12 16xNOVA5xBRAVO

4xNOVA2xBRAVO

18xNOVA6xBRAVO

6xNOVA3xBRAVO

8xMEDIA5xBRAVO

2xMEDIA2xBRAVO

8xMEDIA6xBRAVO

2xMEDIA2xBRAVO

9xMEDIA6xBRAVO

3xMEDIA3xBRAVO 5xBRAVO 2xBRAVO 6xBRAVO 3xBRAVO

15 20xNOVA6xBRAVO

5xNOVA2xBRAVO

21xNOVA6xBRAVO

6xNOVA3xBRAVO

10xMEDIA6xBRAVO

3xMEDIA2xBRAVO

10xMEDIA6xBRAVO

4xMEDIA2xBRAVO

12xMEDIA6xBRAVO

3xMEDIA2xBRAVO 6xBRAVO 2xBRAVO 6xBRAVO 3xBRAVO

18 24xNOVA8xBRAVO

6xNOVA2xBRAVO

24xNOVA9xBRAVO

6xNOVA3xBRAVO

12xMEDIA8xBRAVO

3xMEDIA2xBRAVO

12xMEDIA8xBRAVO

4xMEDIA2xBRAVO

12xMEDIA9xBRAVO

3xMEDIA3xBRAVO 8xBRAVO 2xBRAVO 9xBRAVO 3xBRAVO

20 8xBRAVO 2xBRAVO 9xBRAVO 3xBRAVO 8xBRAVO 2xBRAVO 8xBRAVO 2xBRAVO 9xBRAVO 3xBRAVO 8xBRAVO 2xBRAVO 9xBRAVO 3xBRAVO

24 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 10xBRAVO 4xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO

30 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 4xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO

40 16xBRAVO 4xBRAVO 18xBRAVO 6xBRAVO 16xBRAVO 4xBRAVO 16xBRAVO 4xBRAVO 18xBRAVO 6xBRAVO 16xBRAVO 4xBRAVO 18xBRAVO 6xBRAVO

50 20xBRAVO 5xBRAVO 20xBRAVO 6xBRAVO 20xBRAVO 5xBRAVO 20xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 20xBRAVO 5xBRAVO 24xBRAVO 6xBRAVO

60 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO

70 28xBRAVO 7xBRAVO 30xBRAVO 9xBRAVO 28xBRAVO 7xBRAVO 28xBRAVO 8xBRAVO 30xBRAVO 9xBRAVO 28xBRAVO 7xBRAVO 30xBRAVO 9xBRAVO

75 30xBRAVO 8xBRAVO 30xBRAVO 9xBRAVO 30xBRAVO 8xBRAVO 30xBRAVO 8xBRAVO 30xBRAVO 9xBRAVO 30xBRAVO 8xBRAVO 30xBRAVO 9xBRAVO

80 32xBRAVO 9xBRAVO NA NA 32xBRAVO 9xBRAVO 32xBRAVO 8xBRAVO NA NA 32xBRAVO 9xBRAVO NA NA

TSI_ALACARTE_CET_POUR BROCHURE.indd 8 21/02/11 20:15

Page 8: «A la carte» Programmedonar.messe.de/.../ce-t-tsi-inverter-a-la-carte-eng... · TSI Bravo Shelf and TSI Bravo modules Phase 1 TSI Bravo Shelf and TSI Bravo modules Phase 2 TSI Bravo

S 32 A 7 3 E 04 32 C I 1 00 4 00 1

EPC ModeÀ la carte

Module Type

31 : NOVA32 : BRAVO33 : MEDIA34 : VEDA

AC Voltage

3 : 120VAC

5 : 3x208VAC

6 : 120/240VAC

7 : 220/230/240VAC

8 : 3x400VAC

DC Input

2 : 24VDC

3 : 48VDC

4 : 60VDC

5 : 110VDC

Specify number of Module to install at beginning. Here 4 modules installed.

Maximum Number of module in the system for future extension � lled with blank at beginning. Maximum 32 modules installed in the example.

Monitoring

0 : No monitoring1 : CANDIS display2 : CANDIS TCP/IP4 : CANDIS Display and TCP/IP

AC output distribution

0X : AC distribution line 1 pole0Y : AC distribution line 2 poles0Z : AC distribution line 3 poles00 : Bulk on terminal

Manual by pass

0 : No MBP1 : With MBP

Cabinet type 600mm wide

Our solutions can be integrated in any kind of ANSI or ETSI cabinet. An integration in a customized cabinet is also possible.

«A»La»Carte»»programme»consist»of»a»20»characters»code.

DC distributionCan be done at system or at module level.

Howtoorder?

CE+Ts.a.Phone»:»+32»4»345»67»00Fax»:»+32»4»345»67»01ww.cet.be

PleaseconsulttheCE+TPowersalesteamformoreinformation.

CE+TUK

Phone»:»+44»1246»25»11»11»Fax»:»+44»1246»25»11»33www.cet.be

CE+TChina

Phone»:»+86»756»853»2380»Fax»:»+86»756»853»2396www.cet-china.com

CE+TScandinaviaRegionaloffi ce

Phone»:»+46»70»3107812»Skype»:»marten.ribaeus

CE+TAmerica,Inc

Phone»:»+1»678»405»4636Fax»:»»+1»770»495»0992»www.»cetamerica.com

CETPowerSolutionsIndiaPVTLTD

Phone»:»+91»80»42764617»Email»:»[email protected]

TSI_ALACARTE_CET_POUR BROCHURE.indd 1 21/02/11 20:14