A Brief Update
Jeff Sawyer
September, 2012 HPIC Los Alamos, NM
Laboratory Impex Systems Ltd
Laboratory Impex Systems (LIS)
• Specialize in the design and manufacture and supply of health physics, radiation protection, and process instrumentation / systems
– Stand alone monitors (alpha-beta aerosols, liquids, various gases, dose rate)
– Installed systems– Stack sampling and stack monitoring– and stack flow measurement– Software for compliance monitoring
• Established in 1976
Continuous Monitoring Stations
CMS 2 SmartCAM
Area Gamma Monitor Alpha/Beta in Air Monitor
Some More News
• SmartCAM AB+ passed seismic testing• The Testing was carried out at the Earthquake Engineering
Laboratory at Bristol University.• Used a tri-axial vibratory shaker table testing, in accordance
with IEEE Std 344-2004, IEEEE Recommended Practice for Seismic Qualification of Class 1E Equipment for Nuclear Power Generating Stations. Testing was carried out in three mutually perpendicular test axes in accordance with IEEE Std 344-2004, Para 8.1.5.2
CMS-GAMMA Area Monitor
• Backlit LCD with text and graphics• One or Two Detectors• GM Detectors can be 1,000 meters away• Can use UDI – Universal Detector Interface• Variety of Detector Types and Ranges• Battery Back up• RS-485 or Ethernet communications• Relays and two analog outputs• Stainless Steel Construction• Data accessible via standard Web browser
GM Detector Ranges
• Standard GM Detectors– GDI RANGE (Integrated Electronics, No UDI
Required)– GDI-1304 0.01 rem/h – 1,000 rem/h – GDI-1314 1 mrem/h – 300 rem/h – GDI-1324 0.01 mrem/h – 10 rem/h– GDI-1202 0.01 mrem/h – 4 rem/h– GDI-1301 0.01 rad/h – 1,000 rad/h– GDI-1313 0.001 rad/h – 300 rad/h– GDI-1321 0.3 mrad/h – 10 rad/h
• Other Detectors and Ranges Available!• UDI used for other detector types
Ion Chamber
• ICI-1 Ion Chamber Interface– Current to TTL frequency
converter• ICD-1 Ion Chamber
– Pressurized Chamber– 5 mR/h to 5,000 R/h
• 137Cs live-zero source– 4 µCi or 148 kBq
• <10 m cable length
Hot Cell Monitor HC833
• Simple, panel mount high range monitor• Several different detectors
– Up to 1,000 R/h• Analog, log scale• Simple Alarms • Relay Outputs• Stainless steel housing
Rack-mount Monitoring Systems
• 19” rack mount• Complete dose rate or
particulate monitoring solution• Network using RS-485 or
Ethernet• Key switch and password
protected• Simple LCD text display• Remote light panels and
audible annunciation
Noble Gas and Radioiodine
• Standard Skids• Particulate detector or pre-
filter• 2-inches of lead shielding• 4π lead shield arrangement• Electronics can mount on skid
or remotely• RS-485 or Ethernet• Interface to 9205EMS Data
Management System• Various types of vacuum
pumps available
SmartCAM Continuous Air MonitorAlpha Beta CAM
• Alpha spectrum analysis with peak fitting algorithm used in differential spectrum
• Temperature and pressure spectrum stabilization (Patented)
• Detachable head assembly for remote monitoring
• Gamma dose-rate sensor (option)
• Easy to use, easy to navigate, touch screen display
• Continuous Display of– Concentration (i.e. DAC)
by Nuclide– Dose (i.e. DAC-h) by
Nuclide– Sample Flow– Integrated Sample
Volume– Temperature– Dose Rate (optional)– Pressure
SmartCAM Display
Recent Design Changes
• Upgraded to a more flexible detector cable– Now using a more rugged, easier to use
connector• Added ModBus support (allows ProfiBus)• NRTL tested to UL 61010-1/CSA-C22.2 No. 61010-1
Second Edition: Electrical Equipment for Measurement Control and laboratory Use– For more information, see :
http://ulstandardsinfonet.ul.com/scopes/scopes.asp?fn=61010-1.html
• 47-mm filter in addition to standard cards
Stack Monitor for Positrons
• Used for compliance monitoring• Direct measurement of positron
activity• Simple interface for Daily, Weekly,
Monthly, and Annual Releases• Used with air injection pumps
Vacuum Pumps
• Rotary vane pump– Rebuild “annually”
• Air injection pump– No moving parts– Quieter and cooler– Compressed air required– About 80 psi and 1 cfm
Los Angeles Phoenix
Albuquerque
Dallas
St Louis
Memphis Little Rock
Birmingham
Knoxville
Fort Lauderdale
Baltimore Beltsville
Philadelphia
East Rutherford
Rochester
Columbia
Winston Salem
Kennewick
Hartford
Cleveland
Atlanta
Tampa
San Diego
New Haven Denver
Boston
LIS Cyclotron Installations
Lubbock
Sacramento
Chicago
Seattle
Albany
Augusta
Orlando
Charlottesville
Detroit
Minneapolis
Las Vegas
Alarm and Data Management System – 9205EMS
• 9205 – Generic Network Software Package• Supports multiple communications
protocols• Real Time Display of Measured Values• Generates and Logs Alarms• Accumulates Stack Discharge (Daily, Weekly,
Monthly, Annual)• Database of results (History)• Automated Reports in Word format
Stack Flow Measurement
• Pitot tube averages flow across duct– Stainless steel– Proper placement important
• DP-2001 Differential Pressure– Calibrated for correct pressure range
• 4 to 20 mA Signal to CMS-Pet– Standard Ethernet cable used
Stack Sampling Systems
• Shrouded probes (1” and 1.5”)• Meet ANSI N13.1-1999• Licensed by Texas A&M• NQA-1 Quality Assurance• Seismic analysis performed• Design capability for new
applications
• Gas sampling probes• Various mounting flanges used
System Use With Air Cannons
• Flow rates cannot be accurately measured after the air cannon because of turbulence
• Measuring the concentration prior to the air cannon offers better statistics for lower concentrations
• Software can add in the additional air allowing it to report proper release concentration results
• Monitoring before the air cannon allows proper measurement and reporting of activity releases