    ENGLISH Thank you for choosing Delta DVP-SE. DVP-SE is a 12-point (8DI + 4DO) PLC MPU, offering various instructions and with 16k steps program memory, able to connect to all DVP Slim type series extension modules and high-speed extension modules, including digital I/O (max. 480 I/O points) and analog modules (for A/D, D/A conversion and temperature measurement). 2 points of 100 kHz and 2 points of 10 kHz high-speed pulse output satisfy all kinds of applications. DVP-SE is small in size, and can be installed easily. Users do not have to install any batteries in DVP-SE series PLCs. The PLC programs and the latched data are stored in the high-speed flash memories. EN DVP-SE is an OPEN-TYPE device. It should be installed in a control cabinet free of

    airborne dust, humidity, electric shock and vibration. To prevent non-maintenance staff from operating DVP-SE, or to prevent an accident from damaging DVP-SE, the control cabinet in which DVP-SE is installed should be equipped with a safeguard. For example, the control cabinet in which DVP-SE is installed can be unlocked with a special tool or key.

    EN DO NOT connect AC power to any of I/O terminals, otherwise serious damage may occur. Please check all wiring again before DVP-SE is powered up. After DVP-SE is disconnected, Do NOT touch any terminals in a minute. Make sure that the ground terminal on DVP-SE is correctly grounded in order to prevent electromagnetic interference.

    FR DVP-SE est un module OUVERT. Il doit tre install que dans une enceinte protectrice (boitier, armoire, etc.) saine, dpourvue de poussire, dhumidit, de vibrations et hors datteinte des chocs lectriques. La protection doit viter que les personnes non habilites la maintenance puissent accder lappareil (par exemple, une cl ou un outil doivent tre ncessaire pour ouvrir a protection).

    FR Ne pas appliquer la tension secteur sur les bornes dentres/Sorties, ou lappareil DVP-SE pourra tre endommag. Merci de vrifier encore une fois le cblage avant la mise sous tension du DVP-SE. Lors de la dconnection de lappareil, ne pas toucher les connecteurs dans la minute suivante. Vrifier que la terre est bien relie au connecteur de terre afin dviter toute interfrence lectromagntique.

    Product Profiles

    DVP-12SE

    ss

    -

    1

    23

    4

    5

    6

    7

    9

    88

    10

    11

    12

    3

    12

    13

    14

    15

    16 37.4

    90

    60

    [Figure 1]3 Unit: mm

    1. POWER, RUN, ERROR, COM1 indicator 9. Nameplate 2. RUN/STOP switch 10. Right-side extension port 3. COM1 port (Mini USB) 11. DIN rail mounting slot (35mm) 4. I/O terminals and COM3 comm. port (RS-485) 12. Extension unit clip 5. I/O point and COM2, COM3 indicator 13. COM2 communication port (RS-485)6. Ethernet communication port 14. Mounting rail for extension module 7. DIN rail clip 15. DC power input 8. Mounting hole for extension module 16. Left-side module connection port

    Electrical Specifications Model

    Item DVP12SE11R DVP12SE11T

    Power supply voltage 24 VDC (-15 to 20%) (with counter-connection protection on the polarity of DC input power) DVPPS01/PS02: input 100 to 240 VAC, output 24 VDC/1A (PS02: 2A)

    Connector European standard removable terminal block (Pin pitch: 3.5mm) Operation Maximum power loss time is 10ms or less. Inrush current Max. 7.5 A@24 VDC, I2t = 0.25 A2S Fuse capacity 2.5 A/30 VDC, Polyswitch Power consumption 1.8 W 1.5 W Power protection With counter-connection protection on the polarity of DC input power Insulation resistance > 5 M (all I/O point-to-ground: 500 VDC)

  • - 2 -

    Model Item DVP12SE11R DVP12SE11T

    Noise immunity

    ESD (IEC 61131-2, IEC 61000-4-2): 8kV Air Discharge EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2kV, Digital I/O: 1kV, Analog & Communication I/O: 1kV RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m

    Grounding The diameter of grounding wire cannot be smaller than the wire diameter of terminals L and N (All DVP units should be grounded directly to the ground pole).

    Operation / storage Operation: 0 to 55C (temp.), 50 to 95% (humidity), Pollution degree 2Storage: -25 to 70C (temp.), 5 to 95% (humidity) Vibration / shock resistance

    International standards: IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)

    Weight (g) 145 135 Input Points Spec.

    Items 24 VDC (-15 to 20%) single common port input Input No. X0 to X2 X3 to X7 Input type DC (SINK or SOURCE) Input current (10%) 24 VDC, 5 mA Input impedance 4.7 k Max. frequency 100 kHz 10 kHz

    Off On > 15 VDC Action level On Off < 5 VDC

    Off On < 2.5 s < 20 s Response time On Off < 5 s < 50 s Filter time Adjustable within 0 ~ 20ms by D1020 (Default: 10ms)

    Output Points Spec. Items Relay Transistor Output No. Y0 to Y3 Y0, Y2 Y1, Y3 Max. frequency 1 Hz 100 kHz 10 kHz Working voltage 250 VAC, < 30 VDC 5 to 30 VDC #1

    Resistive 1.5 A/1 point (5 A/COM) 0.5 A/1 point (2 A/COM) Inductive #2 15 W (30 VDC) Max. load

    Lamp 20 WDC/100 WAC 2.5 W (30 VDC) Off On 2 s #3 20 s #3 Response

    time On Off Approx. 10 ms

    3 s #3 30 s #3 #1: UP, ZP must work with external auxiliary power supply 24 VDC (-15 to +20%), rated

    consumption approx. 1mA/point. #2: Life curves

    Contact current(A)0.50.1 0.2

    50

    0.3 0.7 1 2

    200300

    500

    100

    1,0002,0003,000

    Ope

    ratio

    n(X

    10)3

    120 VAC, resistive30 VDC, induct ive (t=7ms)

    240 VAC, inductive (cos 0.4)=120 VAC, inductive (cos =0.4)

    30 VDC, inductive(t=40ms)

    [ Figure 2 ] #3: Load = 0.5A I/O Configuration

    Input Output I/O Configuration Model Point Type Point Type Relay Transistor

    DVP12SE11R Relay

    DVP12SE11T

    8 DC (Sink Or Source) 4

    Transistor

    S/ SX0X1X2

    X5X6X7

    Y0Y1Y2

    SGCOM3+COM3-

    X4

    C0

    Y3

    X3

    S/ SX0X1X2

    X5X6X7

    Y1Y2Y3

    SGCOM3+COM3-

    X4

    Y0

    UP

    X3

    ZP

  • - 3 -

    Dimension & Installation Please install the PLC in an enclosure with sufficient space around it to allow heat dissipation, See [Figure 3]. Direct Mounting: Use M4 screw according to the

    dimension of the product. DIN Rail Mounting: When mounting the PLC to

    35mm DIN rail, be sure to use the retaining clip to stop any side-to-side movement of the PLC and reduce the chance of wires being loose. The retaining clip is at the bottom of the PLC. To secure the PLC to DIN rail, pull down the clip, place it onto the rail and gently push it up. To remove the PLC, pull the retaining clip down with a flat screwdriver and gently remove the PLC from DIN rail.

    Wiring 1. Use 22-16AWG (1.5mm) single or multiple core wire

    on I/O wiring terminals. See the figure in the right hand side for its specification. PLC terminal screws should be tightened to 1.90 kg-cm (1.65 in-lbs) and please use only 60/75C copper conductor.

    22-16AWG

    < 1.5mm

    2. DO NOT wire empty terminal. DO NOT place the I/O signal cable in the same wiring circuit.

    3. DO NOT drop tiny metallic conductor into the PLC while screwing and wiring. Tear off the sticker on the heat dissipation hole for preventing alien substances from dropping in to ensure normal heat dissipation of the PLC.

    Power Supply The power input of DVP-SE is DC. When operating DVP-SE please note the following points: 1. The power is connected to two terminals, 24 VDC and 0 V, and the range of power is

    20.4 to 28.8 VDC. If the power voltage is less than 17.5 VDC, the PLC will stop running, all outputs will go Off, and the ERROR indicator will start to blink continuously.

    2. The power shutdown for less than 10ms will not affect the operation of the PLC. However, the shutdown time that is too long or the drop of power voltage will stop the operation of the PLC, and all outputs will go off. When the power returns to normal status, the PLC will automatically resume the operation. (Please take care of the latched auxiliary relays and registers inside the PLC when doing the programming).

    Safety Wiring

    Since DVP-SE is only compatible with DC power supply, Deltas power supply modules (DVPPS01/DVPPS02) are the suitable power supplies for DVP-SE. We suggest you install the protection circuit at the power supply terminal to protect DVPPS01 or DVPPS02. See the figure below.

  • - 4 -

    AC power supply:100 ~ 240VAC, 50/60Hz Breaker

    Emergency stop: This button cuts off the system power supply when accidental emergency takes place.

    Power indicator AC power supply load

    Power supply circuit protection fuse (2A) DVPPS01/DVPPS02

    DC power supply output: 24 VDC, 500 mA DVP-PLC (main processing unit)

    Digital I/O module

    Input Point Wiring

    There are 2 types of DC inputs, SINK and SOURCE. (See the example below. For detailed point configuration, please refer to the specification of each model.)

    DC Signal IN SINK mode Input point loop equivalent circuit

    DC Signal IN SOURCE mode Input point loop equivalent circuit

    24G

    +24V

    S/S

    X0

    X1

    [ Figure 5 ]

    +24V

    24G

    S/S

    X0

    X1

    [ Figure 6 ]

    Output Point Wiring

    1. DVP-SE has two output modules on it, relay and transistor. Be aware of the connection of shared terminals when wiring output terminals.

    2. Relay output terminals, Y0 to Y3 of relay models use C0 common port. See [Figure 7]. When the output points are enabled, their corresponding indicators on the front panel will be on.

    3. Transistor output terminals, Y0 to Y3 of transistor (NPN) models use UP, ZP common port. See [Figure 8].

    4. Isolation circuit: The optical coupler is used to isolate signals between the circuit

    inside PLC and input modules.

  • - 5 -

    Relay (R) output circuit wiring

    DC power supply Emergency stop: Uses external switch Fuse: 5 to10A fuse at the shared terminal of output contacts to protect the output circuit Transient voltage suppressor (SB360 3A 60V): Extends the life span of contact.

    1. Diode suppression of DC load: Used when in smaller power [Figure 10a] 2. Diode + Zener suppression of DC load: Used when in larger power and frequent On/Off

    [Figure 10b]

    Incandescent light (resistive load) Absorber: Reduces the interference on AC load [Figure 11]

    Transistor (T) output circuit wiring

    DC power supply Emergency stop Circuit protection fuse

  • - 6 -

    The output of the transistor model is open collector. If Y0/Y1 is set to pulse output, the output current has to be bigger than 0.1 A to ensure normal operation of the model. 1. Diode suppression: Used when in smaller power [Figure 13a] 2. Diode + Zener suppression: Used when in larger power and frequent On/Off [Figure 13b]

    Manually exclusive output: For example, Y2 and Y3 control the forward running and reverse running of the motor, forming an interlock for the external circuit, together with the PLC internal program, to ensure safe protection in case of any unexpected errors.

    RS-485 Wiring

    Figure 14

    D+ D- SG D+ D- SG SG D+ D-

    3

    4

    1 2 2

    3

    4 Master node Slave node Terminal resistor Shielded cable

    Note: 1. Terminal resistors are suggested to be connected to master and the last slave with resistor value of

    120. 2. To ensure communication quality, please apply double shielded twisted pair cable (20AWG) for wiring.

    Ethernet (RJ45) Wiring Please use the twisted pair CAT-5e to connect the Ethernet RJ45 communication port.

    Tx+ N/C Tx- Rx- Rx+ N/C

    N/C N/C

    Note: The DVP-SE series PLC is equipped with the Auto MDI/MDIX function. It does not need any jumper wire when it connects to the network device.

    Setting the Ethernet The DVP-SE series PLC contains a built-in Ethernet communication port. Users have to set the network parameter before the PLC connects to other network devices. The default parameter setting values are 192.168.1.5 (the IP address) and 255.255.255.0 (the subnet mask). Users can set the parameter by using DCISoft, or by using the PLC program to write the values into the network control register (CR). Software: Start the DCIsoft, and connect the PC to the DVP-SE series PLC through

    the ehternet cable. Enter Communication Setting page in DCISoft, and choose Ethernet communication port. Then, click Search to search for the picture representing the DVP-SE series PLC. After users click the picture twice, the setting page appears. Finally, enter the related parameters, and click Apply to finish the setting.

    PLC program: Users use the instruction To to write the IP address (CR#88, 89) and the subnet mask (CR#90, 91). For example, when the IP address is 192.168.1.5, users write 192.168 (HC0A8) into CR#89, and .1.5 into CR#88 (H105).

    Note: When users use the instruction From/To to read the data from the network control register and write the data into it, the module number is K108.

    Precision of the RTC (Second/Month) Temperature

    (C/F) 0/32 25/77 55/131

    Maximum error (Second) -117 52 -132

    Duration in which the RTC is latched: Two weeks

  • - 7 -

    DVP DVP-SE 12 8 + 4 PLC 16k steps I/O 480 A/DD/A 100 kHz 10 kHz PLC

    DVP-SE

    OPEN TYPE

    COM1 Mini USB , PLC ,

    1 [Figure 1]mm

    1. COM1 9.

    2. RUNSTOP 10. I/O

    3. COM1 Mini USB 11. DIN 35mm

    4. COM3RS-485 12. I/O

    5. COM2COM3 13. COM2RS-485

    6. 14. I/O

    7. DIN 15.

    8. I/O 16. I/O

    DVP12SE11R DVP12SE11T

    24 VDC (-15 ~ 20%)

    DVPPS01/PS02 100 ~ 240 VAC 24 VDC/1A (PS02: 2A)

    3.5mm 10ms

    Max. 7.5A@24VDC, I2t = 0.25A2S

    2.5 A/30 VDC (Polyswitch)

    1.8 W 1.5 W

    > 5M 500 VDC

    ESD (IEC 61131-2, IEC 61000-4-2): 8kV Air Discharge EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2kV, Digital I/O: 1kV, Analog & Communication I/O: 1kV RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m

  • - 8 -

    DVP12SE11R DVP12SE11T

    PLC

    0 ~ 55C50 ~ 95% 2

    -25 ~ 70C5 ~ 95%

    IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)

    (g) 145 135

    24 VDC-15 ~ 20%

    No. X0 ~ X2 X3 ~ X7

    S/S SINK SOURCE

    10% 24 VDC5 mA

    4.7 k

    100 kHz 10 kHz

    Off On > 15 VDC

    On Off < 5 VDC Off On < 2.5 s < 20 s

    On Off < 5 s < 50 s

    D1020 0 ~ 20 ms 10 ms

    No. Y0 ~ Y3 Y0, Y2 Y1, Y3

    1 Hz 100 kHz 10 kHz

    250 VAC< 30 VDC 5 ~ 30 VDC #1

    1.5 A /1 5 A/COM 0.5 A/1 2 A/COM

    #2 15 W30 VDC

    20 WDC/100 WAC 2.5 W30 VDC

    Off On 2 s #3 20 s #3

    On Off 10 ms

    3 s #3 30 s #3

    #1UP, ZP 24 VDC-15 ~ +20% 1 mA #2 [Figure 2] #3 0.5A

    I/O

    DVP12SE11R

    DVP12SE11T 8

    Sink Source4

    PLC PLC 3 [Figure 3]

    M4 DIN 35mm DIN

  • - 9 -

    I/O I/O 1. 22-16AWG (1.5mm) 3

    PLC 1.90 kg-cm (1.65 in-lbs) 60/75C 2. 3. PLC

    DVP-SE 1. 24VDC 0V 20.4~28.8VDC 17.5VDC

    PLC OffERROR LED 2. 10ms PLC

    PLC OffPLC PLC

    DVP-SE DC Only (DVPPS01/DVPPS02) DVP-SE DVPPS01/DVPPS02 4 [Figure 4]

    100 ~ 240 VAC, 50/60 Hz

    2A DVPPS01/DVPPS02

    24 VDC500 mA DVP PLC

    DC SINK SOURCE 4 [Figure 5] [Figure 6]

    1. DVP-SE PLC

    2. Y0~Y3 C0 5 [Figure 7]

    3. NPN Y0~Y3 UPZP 5 [Figure 8]

    4. PLC

    5 [Figure 9] ~ [Figure 11]

    5~10 A

  • - 10 -

    1. DC 5 [Figure 10a]

    2. DC + Zener On/Off

    5 [Figure 10b] 5 [Figure 11]

    [Figure 12] ~ [Figure 13b]

    1. DC 6 [Figure 13a]

    2. DC + Zener On/Off

    6 [Figure 13b] Y2 Y3

    PLC

    RS-485 6 [ Figure 14]

    1. 120

    2. 20AWG

    (RJ45) CAT-5e RJ45

    Tx+ N/C N/C Tx- N/C N/C

    Rx+ Rx-

    DVP-SE Auto MDI/MDIX

    DVP-SE :192.168.1.5 (IP )255.255.255.0 () DCISoft PLC (CR) PLC DCISoft PC DVP-SE

    DCISoft Ethernet DVP-SE IP

    PLC PLC To IP (CR#88, 89)(CR#90,91) IP :192.168.1.5 CR#89 192.168 (HC0A8) ; CR88 .1.5 (H105)

    DVP-SE From/To (CR) K108

    (C/F) 0/32 25/77 55/131

    -117 52 -132

  • - 11 -

    DVP DVP-SE 12 8 + 4 PLC 16k steps I/O / 480 A/DD/A 100 kHz 10 kHz PLC

    DVP-SE

    (OPEN TYPE)

    COM1 Mini USB , PLC ,

    1 [Figure 1]mm

    1. COM1 8.

    2. RUNSTOP 9. I/O

    3. COM1 (Mini USB) 11. DIN 35mm

    4. COM3RS-485 12. I/O

    5. COM2COM3 13. COM2RS-485

    6. 14. I/O

    7. DIN 15.

    8. I/O 16. I/O

    DVP12SE11R DVP12SE11T

    24VDC (-15 ~ 20%)

    DVPPS01/PS02 100 ~ 240 VAC 24 VDC/1 A (PS02: 2 A)

    3.5 mm 10ms

    Max. 7.5 A@24 VDC, I2t = 0.25A2S

    2.5A /30 VDC(Polyswitch)

    1.8 W 1.5 W

    > 5M 500 VDC

    ESD (IEC 61131-2, IEC 61000-4-2): 8kV Air Discharge EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2kV, Digital I/O: 1kV, Analog & Communication I/O: 1kV RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m

    PLC

  • - 12 -

    DVP12SE11R DVP12SE11T

    0 ~ 55C50 ~ 95% 2

    -25 ~ 70C5 ~ 95%

    IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)

    (g) 145 135

    24 VDC-15 ~ 20%

    No. X0 ~ X2 X3 ~ X7

    S/S

    10% 24 VDC5 mA

    4.7 k

    100 kHz 10 kHz

    Off On > 15 VDC

    On Off < 5 VDC Off On < 2.5 s < 20 s

    On Off < 5 s < 50 s

    D1020 0 ~ 20 ms 10 ms

    No. Y0 ~ Y3 Y0Y2 Y1Y3

    1 Hz 100 kHz 10 kHz

    LED ON OFF

    250 VAC< 30 VDC 5 ~ 30 VDC #1

    1.5 A /1 5 A/COM 0.5 A/1 2 A/COM

    #2 15 W30 VDC

    20WDC/100WAC 2.5 W30 VDC

    Off On 2 s #3 20 s #3

    On Off 10 ms

    3 s #3 30 s #3

    #1UP, ZP 24 VDC-15 ~ +20% 1 mA #2 [Figure 2] #3 0.5A

    / I/O

    DVP12SE11R

    DVP12SE11T 8

    4

    NPN

  • - 13 -

    PLC PLC 3 [Figure 3]

    M4 DIN 35mm DIN

    I/O I/O 1. 22 ~ 16AWG1.5mm 3

    PLC 1.90 kg-cm1.65 in-lbs 60/75C 2. 3. PLC

    DVP-SE 1. 24 VDC 0 V 20.4 ~ 28.8 VDC 17.5

    VDC PLC OffERROR LED 2. 10 ms PLC

    PLC OffPLC PLC

    DVP-SE DC Only (DVPPS01/DVPPS02) DVP-SE DVPPS01/DVPPS02 4 [Figure 4]

    100 ~ 240 VAC, 50/60 Hz 2A DVPPS01/DVPPS02 24 VDC500 mA DVP PLC

    DC DC 4 [Figure 5] [Figure 6]

    1. DVP-SE PLC -NPN -PNP

    2. Y0 ~ Y3 C0 5 [Figure 7]

    3. NPN Y0 ~ Y3 UPZP 5 [Figure

    8] 4. PLC 5 [Figure 9] ~ [Figure 11]

    5 ~ 10A

  • - 14 -

    1. DC 5 [Figure 10a]

    2. DC + Zener On/Off

    5 [Figure 10b]

    5 [Figure 11]

    [Figure 12] ~ [Figure 13b]

    1. DC 6 [Figure 13a]

    2. DC + Zener On/Off

    6 [Figure 13b] Y2 Y3

    PLC

    RS-485 6 [Figure 14]

    1. 120

    2. 20AWG

    (RJ45)

    CAT-5e RJ45 Tx+ N/C Tx- Rx- Rx+ N/C

    N/C N/C DVP-SE Auto MDI/MDIX

    DVP-SE

    :192.168.1.5 (IP )255.255.255.0 () DCISoft

    PLC (CR)

    PLC DCISoft PC DVP-SE DCISoft Ethernet

    DVP-SE

    IP

    PLC PLC To IP (CR#88, 89)

    (CR#90,91) IP :192.168.1.5 CR#89 192.168 (HC0A8) ;

    CR88 .1.5 (H105)

    DVP-SE From/To (CR)

    K108

    (C/F) 0/32 25/77 55/131

    -117 52 -132

  • - 15 -

    ....... TRKE .........

    Deltann DVP-SE modelini setiiniz iin teekkrler. DVP- SE PLC rn 12-nokta (8DI + 4DO) MPU, eitli komutlar ve 16K step program ile tm DVP-S serisi genileme modlleri (Maksimum 480 adet dijital I/O) ve yksek hzl ilave modllerle (A/D, D/A dnm ve scaklk lm) ile balanabilir. 2 adet 100 kHz ve 2 adet 10 kHz yksek hzl pulse k ile birok uygulamann gereksinimlerini karlar. DVP-SE rn kk boyutlu ve kurulumu kolaydr. Bu bilgi dkman sadece rnn elektriksel zellikleri, genel fonksiyonlar, kurulumu

    ve balants ile ilgili bilgiler salar. Detayl programlama ve DVP-SE uygulama komutlar ile ilgili ltfen DVP-SE Operation Manual: Programming dkmann inceleyiniz. Opsiyonel evre birimleri ile ilgili ltfen kutunun iindeki rnle birlikte gelen bilgi dkmann inceleyiniz. DVP-SE serisi PLClere herhangi bir pil taklmas gerekmez. PLC programlar ve kalc veriler yksek hzl flash belleklerde saklanr.

    Bu rn AIK TP bir PLCdir. PLC rn toz, rutubet, elektrik oku riski ve titreimden uzak yerlerde muhafaza edilmelidir. Ayrca cihaza yetkili olmayan kiilerin mdahale etmesini engelleyecek nlemler alnmaldr. (rnein rnn kurulduu panoya kilit konulmas gibi). Aksi halde kullanclar ve/veya PLC zarar grebilir.

    Giri/k terminallerine kesinlikle AC besleme balamaynz. Aksi halde rn zarar grebilir. Enerji vermeden nce rnn tm balantlarn kontrol ediniz. Elektromanyetik grlty nlemek iin topraklamann dzgn yapldna emin olunuz. Enerjili iken rn terminallerine mdahale etmeyiniz.

    COM1 bu model zerinde Mini USB haberleme portudur. Bu port sadece PLCden program ekmek, PLCye program yklemek ve geici olarak program hata ayklama iin kullanlabilir. Uzun sreli grntleme ilevi iin uygun deildir.

    rn Grn ngilizce (English) blmnde ekil 1ye [Figure 1] baknz. Birim: mm.

    1. POWER, RUN, ERROR, COM1 indikatr 9. Etiket

    2. RUN/STOP anahtar 10. Sa-kenar ilave port 3. COM1 port (Mini USB) 11. DIN ray montaj slotu (35mm)

    4. I/O terminalleri ve COM3 hab. portu (RS-485) 12. lave nite klipsi

    5. I/O nokta ve COM2,COM3 indikatr 13.COM2 haberleme portu (RS-485)

    6. Ethernet haberleme portu 14. lave niteler iin montaj ray 7. DIN ray klip 15. DC power girii

    8. lave unite iin montaj delii 16. Sol-kenar modl balant portu

    Elektriksel zellikler Model

    Madde DVP12SE11R DVP12SE11T

    Besleme voltaj 24VDC (-15 ~ 20%) (DC giri besleme ters balant korumas) DVPPS01/PS02: giri 100 ~ 240 VAC, k 24 VDC/ 1A (PS02: 2A)

    Konnektr Avrupa standart sklebilir terminal blok (Pin ls: 3.5mm) alma Maksimum enerji kesintisi zaman 10 ms veya alt.

    Sznt Akm Maksimum 7.5 A@24 VDC, I2t = 0.25A2S

    Sigorta Kapasitesi 2.5 A/30 VDC, Polyswitch

    G Tketimi 1.8 W 1.5 W Besleme Koruma DC giri besleme ters balant korumas

    Izolasyon direnci > 5 M (Tm I/O nokta - ground: 500 VDC)

  • - 16 -

    Model Madde

    DVP12SE11R DVP12SE11T

    Ses Bakl

    ESD (IEC 61131-2, IEC 61000-4-2): 8kV Hava Dearj EFT (IEC 61131-2, IEC 61000-4-4): G Hatt: 2kV, Dijital I/O: 1kV, Analog & Haberleme I/O: 1kV RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m

    Topraklama Topraklama kablosunun kesiti 24V - 0V terminalleri kablolar kesitinden kk olmamaldr. (Tm DVP rnleri dorudan ground ucundan topraklanmaldrlar).

    alma/Saklama alma: 0 ~ 55C (scaklk), 50 ~ 95% (rutubet), Kirlenme derece 2 Saklama: -25 ~ 70C (scaklk), 5 ~ 95% (rutubet)

    Titreim/ok direnci Uluslararas Standartlar: IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)

    Arlk (g) 145 135

    Giri Noktas zellik.Madde 24 VDC (-15 ~ 20%) tek ortak u girii Giri No. X0 ~ X2 X3 ~ X7

    Giri Tipi DC (SINK veya SOURCE)

    Giri Akm (10%) 24 VDC, 5 mA

    Giri Empedans impedance 4.7 k

    Maksimum frekans 100 kHz 10 kHz Off On > 15 VDC

    Aktif seviye On Off < 5 VDC

    Off On < 2.5 s < 20 s Cevap Zaman On Off < 5 s < 50 s Filtre zaman D1020 datasndan 0 ~ 20 ms (Default: 10 ms)

    k Noktas zellikMadde Rle Transistor

    k No. Y0 ~ Y3 Y0, Y2 Y1, Y3 Maksimum frekans 1 Hz 100 kHz 10 kHz

    alma Voltaj 250 VAC, < 30 VDC 5 ~ 30 VDC #1

    Rezistif 1.5 A /1 nokta (5 A/COM) 0.5 A/1 nokta (2 A/COM)

    Endktif #2 15 W (30 VDC) Maksimum Yk Lamba 20 WDC/100 WAC 2.5 W (30 VDC)

    Off On 2 s #3 20 s #3 Cevap Zaman On Off

    Yaklak 10 ms 3 s #3 30 s #3

    #1: UP, ZP harici 24 VDC (-15 ~ +20%) g kayna ile alr, g tketimi oran yaklak 1 mA/nokta.

    #2: ngilizce (English) blmnde ekil 2ye [Figure 2] baknz. #3: Yk = 0.5 A.

    I/O Konfigurasyon Giri k I/O konfigurasyon

    Model Nokta Tip Nokta Tip Rle Transistor

    DVP12SE11R Rle

    DVP12SE11T 8

    DC (Sink veya

    Source) 4

    Transistor

    ngilizce (English)

    blmnde baknz

    ngilizce (English)

    blmnde baknz

  • - 17 -

    ller & Kurulum Ltfen PLCnin kurulumunu yaparken s dalmnn verimli olmas iin evresinde gerekli boluun brakldna emin olunuz. Ltfen ngilizce (English) blmnde ekil 3e [Figure 3] baknz.

    Dorudan Montaj: rnn llerine gre ltfen M4 vida kullannz.

    DIN Ray Montaj: PLC rn 35mm DIN rayna monte edilecei zaman, rnn hareket ederek kablo balantlarnn zarar grmesini engellemek iin sabitleyici klipsleri kullannz. Sabitleyici klipsler PLCnin altnda olup, PLCyi DIN rayna sabitlemek iin bu klipsleri bastrnz. PLCyi yerinden karmak iinse ince tornavida yardm ile nce bu klipsleri anz ve PLCyi DIN rayndan ekerek kartnz.

    Balant 1. PLCnin I/O terminal balantlarn yapmak iin

    22-16AWG (1.5mm) tek damarl veya ok damarl kablo kullannz. Kablo zellikleri yandaki ekilde gsterildii gibi olmaldr. PLC terminal vidalar 1.90 kg-cm (1.65 in-lbs) orannda sklmal ve sadece bakr iletkenler kullanlmaldr.

    22-16AWG

    < 1.5mm

    2. Bo terminallere balant yapmaynz ve I/O sinyal kablolar ile power kablolarn ayr kablo bloundan balaynz.

    3. PLC kablo balantlarn yaparken PLCnin iine iletken paracklar drmeyiniz. Balantlar tamamladktan sonra s dalmn salanabilmesi iin kk cisimlerin PLCnin iine dmesini engelleyen koruyucu etiketleri kartnz.

    G Kayna (Power Supply)

    DVP-SE serisi rnlerin besleme girii DCdir. DVP-SE serisi rnleri kullanrken aadaki uyarlara dikkat ediniz: 1. Besleme, 24 VDC ve 0 V terminallerine balanmal ve besleme voltaj 20.4 ~ 28.8

    VDC aralnda olmaldr. Eer besleme voltaj 17.5 VDC altna derse, PLC almay durdurur, tm klar OFF olur ve ERROR indikatr srekli flash yapar.

    2. 10 ms altndaki enerji kesintisi PLCnin almasna etki etmeyecektir. Fakat daha uzun sureli bir enerji kesintisi veya voltaj dmesi durumunda PLC almas duracak ve tm klar OFF olacaktr. PLCnin beslemesi normal duruma dndnde, PLC otomatik olarak normal almasna geri dner. (PLC programlanaca zaman iindeki kalc rle ve registerlerin kullanmna dikkat ediniz).

    Gvenli Balant

    DVP-SE rnleri sadece DC voltaj ile beslenir. DELTAnn g kaynaklar (DVPPS01/DVPPS02), DVP-SE PLClerin beslemesi iin uygundur. DVPPS01 veya DVPPS02 rnlerini korumak iin power supply terminallerine koruyucu devre kurulmas nerilir. ngilizce (English) blmnde ekil 4e [Figure 4] baknz. AC power supply: 100 ~ 240 VAC, 50/60 Hz Devre kesici Acil Stop: Acil durumda sistemin enerjisini kesmek iin kullanlr.

    Power indikatr AC power supply yk Power supply devre koruma sigortas (2A) DVPPS01/DVPPS02 DC power supply k: 24 VDC, 500 mA DVP-PLC (Ana ilemci birimi) Digital I/O modl

    Giri Balants

  • - 18 -

    2 eit DC giri vardr, SINK veya SOURCE. ngilizce (English) blmde ekil 5e [Figure 5] ve ekil 6ya [Figure 6] baknz.

    k Balants

    1. DVP-SE serisi rnlerde 2 eit k vardr. Rle ve Transistr (NPN/PNP). k terminal balantlarn yaparken ortak terminallerin kullanmna dikkat ediniz. (COM).

    2. Rle k terminalleri, Y0 ~ Y3 rle k modellerde C0 ortak ucunu kullanr. ngilizce (English) blmde ekil 7ye [Figure 7] baknz. k terminalleri aktif olduu zaman n panelde klara karlk gelen ilgili indikatrler de ON olur.

    3. Transistr k terminalleri (NPN), Y0 ~ Y3 UP, ZP ortak ularn kullanr. ngilizce (English) blmde ekil 8e [Figure 8] baknz.

    4. zolasyon devresi: PLC i devreleri ve giri modlleri arasn izole etmek iin optokuplr kullanlr.

    Rle (R) k devre balants

    Balant detay iin ngilizce (English) blmde ekil 9a - ekil 11e [Figure 9] ~ [Figure 11] baknz. DC power supply Acil stop: Harici switch kullanr.

    Sigorta: k devrelerini korumak iin klarn ortak terminallerinde 5~10A sigorta kullanr. Yksek gerilim darbe koruyucu (SB360 3A 60V): Kontak mrn uzatmak iin kullanlr.

    1. DC yk diyot koruma: Dk power olduu zaman kullanlr. (ngilizce (English) blmde ekil 10aya [Figure 10a] baknz).

    2. DC yk Diyot + Zener koruma: Yksek power veya ok sk On/Off durumlarda kullanlr. (ngilizce (English) blmde ekil 10bye [Figure 10b] baknz)

    Akkor Lamba (resistif yk)

    Dalga Emici (Absorber): AC ykteki grlty nlemek iin kullanlr. (ngilizce (English) blmde ekil 11e [Figure 11] baknz)

    Transistr (T) k devre balants

    Balant detay iin ngilizce (English) blmde ekil 12 ~ ekil 13bye [Figure 12] ~ [Figure 13] baknz.

    DC power supply Acil stop Devre koruma sigortas

    Transistor kl modeler ak kolektr(open collector) dr. Eer Y0/Y1 pulse k olarak ayarlandysa, normal alma iin k akm 0.1Aden byk olmaldr. 1. Diyot koruma: Dk power olduu zaman kullanlr. (ngilizce (English) blmde

    ekil 13aya [Figure 13a] baknz) 2. Diyot + Zener koruma: Yksek power veya ok sk On/Off durumlarda kullanlr

    (ngilizce (English) blmde ekil 13bye [Figure 13b] baknz)

    Manual tek k: rnein, Y2 ve Y3 klar motorun ileri ve geri almasn kontrol etsin. klarn ayn anda almasn ve beklenmeyen hatalar nlemek iin PLC programnda ve harici devre balantsnda gerekli nlemler alnarak ayn anda sadece tek kn almas salanabilir.

    RS-485 Wiring

    ngilizce (English) blmde ekil 14ye [Figure 14] baknz.

    Master istasyon Slave istasyon Terminal resistor Ekranl kablo Not: 1. Terminal resistorun master ve son slave arasnda 120W olacak ekilde balanlmas nerilir. 2. Haberleme kalitesini arttrmak iin, ltfen balantda double shield (ift ekranl) twisted pair

    (sarmal iftli) kablo (20AWG) kullannz.

    Ethernet (RJ45) Balants

  • - 19 -

    Ethernet RJ-45 haberleme portuna balant iin ltfen sarmal iftli CAT-5e kullann. Tx+ N/C Tx- Rx- Rx+ N/C

    N/C N/C

    Not: DVP-SE serisi PLC Auto MDI/MDIX fonksiyonu ile donatlmtr. Bir aa balanrken cross balantya ihtiya duymaz.

    Ethernet Ayar DVP-SE serisi PLC dahili Ethernet haberleme portu ierir. PLC dier a aygtlarna balanmadan nce a ayarlarnn yaplmas gerekmektedir. Varsaylan a parametreleri 192.168.1.5 (IP adresi) ve 255.255.255.0 (alt a maskesi) eklindedir. Kullanclar kendi parametrelerini DCISoft yardm ile veya PLC ladder programndan a kontrol registerlarna (CR) yazma yaparak ayarlayabilir.

    Yazlm: DCIsoft yazlmn balatn ve DVP-SE PLCyi ethernet kablosu aracl ile PCye balayn. DCIsoft ierisinde Communication Setting sayfasna girin ve Ethernet haberleme portunu sein. Daha sonra DVP-SE serisi PLC resmini gsteren simgeyi buldurmak iin Search zerine tklayn. Resim simgesi bulunduktan sonra zerine ift tkladnzda ayarlar penceresi alacaktr. Son olarak gerekli parametreleri girdikten sonra ayar ilemini tamamlamak iin Apply butonuna tklayn.

    PLC program: Kullanclar, IP adresi (CR#88, 89) ve Alt A Maskesi (CR#90, 91) deerlerini yazdrmak iin TO komutunu kullanr. rnein; IP adresi 192.168.1.5 ise kullanclar 192.168 (HC0A8) deerini CR#89 ierisine ve 1.5 (H0105) deerini CR#88 ierisine yazmaldr.

    Not: Kullanclar FROM/TO komutlarn a kontrol registerlarndan data okumak ve data yazmak iin kullandnda modl numaras K108 dir.

    RTC Doruluu (Saniye/Ay) Scaklk (C/F) 0/32 25/77 55/131 Maksimum hata

    (Saniye) -117 52 -132

    RTC kalc olduu sre: ki hafta