  • NITON XLp 300A/700A SERIES LEAD-BASED-PAINT

    ANALYZER

    USERS GUIDE

    Part Number 500-926

    Version 4.2

  • Thermo Electron Corporation Portable Elemental Analysis

    900 Middlesex Turnpike, Building 8Billerica, Massachusetts 01821 USA

    Voice: (800) 875-1578 +1 (978) 670-7460 Fax: +1 (978) 670-7430Email: [email protected] web: http://www.niton.com

    Copyright Thermo Electron Corporation1993, 1994, 1995, 1996, 1997, 1998, 1999, 2000, 2001, 2002, 2003, 2004.

    All Rights Reserved

    No part of this publication may be reproduced, read or stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, by photocopying, recording, or otherwise, without the prior permission of Thermo Electron Corporation.

    NITON XLp, 300 Series, and SpectraView are trademarks of Thermo Electron Corporation.

    The information in this Users Guide is furnished for informational purposes only, is subject to change without notice, and should not be construed as a commitment by Thermo Electron Corporation. Thermo Electron Corporation assumes no liability for any errors, inaccuracies or omissions that may appear in this book.

    XLp300 Series Lead-based-Paint Analyzer Users Guide XLp300 Series Lead-based-Paint Analyzer

    Produced in the United States of America

    Registration: Thermo Electron Corporation manufactures the XLp 300 Series Lead-based-Paint Analyzer under the authority of the Commonwealth of Massachusetts, in accordance with Radioactive Materials License 55-0238

  • ! Warning: Do not attempt to use this instrument without first reading and understand-ing the entire Users Guide!

  • YOUR NITON XRF ANALYZER .................................................. IUnpacking and Assembling Your NITON XLp XRF Analyzer ............ iThe NITON XLp XRF Analyzer Overview ........................................... iiThe Control Panel ................................................................................... iiInstrument Startup .................................................................................. ivScreen Contrast....................................................................................... vi

    RADIATION SAFETY ..................................................................... 1Typical Radiation Doses in millirem (NCRP, 1987).............................. 3How to Use Your NITON XLp .............................................................. 5 Shutter safety ......................................................................................... 7Monitoring your Radiation Exposure ..................................................... 8Procedures for Instrument Loss or Damage IN THE USA .................... 11Procedures for Instrument Loss or Damage OUTSIDE THE USA ....... 12XLp Radiation Dose Profile - Wood Substrate ..................................... 13

    THE MENU SYSTEM ..................................................................... 1The Main Menu ...................................................................................... 2The Mode Menu ..................................................................................... 4The Utilities Menu.................................................................................. 6 The Data Menu ...................................................................................... 9The Data Menu - Second Page ............................................................... 12The View Libraries Menu....................................................................... 13The Common Setup Menu...................................................................... 14The Calibrate Menu ................................................................................ 16The Erase Menu...................................................................................... 18The Serial Output Menu ......................................................................... 20The Set Protocol Menu ........................................................................... 21The Hardware Setup Menu..................................................................... 23The Source Menu.................................................................................... 25The Source Time Menu .......................................................................... 26The Source Match Number Menu .......................................................... 28

    ALLOY TESTING ........................................................................... 1Using Alloy Testing Mode ..................................................................... 1

    PB PAINT MODE .......................................................................... 1Using Pb Paint Mode .............................................................................. 1The Pb Paint Mode Menu ....................................................................... 2The Standard Mode Menu ...................................................................... 4The K+L Mode Menu............................................................................. 6The Set Action Level Screen .................................................................. 8

  • Taking a Reading.................................................................................... 10Standard Mode Results Screen ............................................................... 12K+L Mode Results Screen...................................................................... 13The Data Entry Screens .......................................................................... 14Using The Data Entry Screen ................................................................. 16A Sample Parameter Value Sub-screen.................................................. 19Calibrating the XLp 300A/700A series Analyzer for Lead-in-Paint Analysis...................................................................... 21

    THIN SAMPLE TEST MODES ......................................................... 1Using Thin Sample Test Modes ............................................................. 2The Thin Sample Mode Menu................................................................ 3Dust Wipe Testing Mode Menu ............................................................. 537mm Testing Mode Menu .................................................................... 1025mm Testing Mode Menu .................................................................... 13TSP Filter Mode ..................................................................................... 16Standard Testing Mode Menu ................................................................ 19Analyzing Thin Samples......................................................................... 21The Data Entry Screen............................................................................ 24Setting Up Custom Barcodes.................................................................. 26Navigating the Data Entry Screen .......................................................... 27The Virtual Keyboard ............................................................................. 28NITON Environmental Test Platform .................................................... 29

    BULK SAMPLE TEST MODES ....................................................... 1Using Bulk Sample Test Modes ............................................................. 1The Bulk Sample Mode Menu................................................................ 2Standard Soil Mode ................................................................................ 4Industrial Bulk Cu/Zn/Pb Testing Mode ................................................ 6Industrial Bulk Ta/Hf/Re Testing Mode................................................. 7Analyzing Bulk Samples ........................................................................ 8To Prepare or Not to Prepare In Situ vs. Ex Situ................................. 12The Data Entry Screen............................................................................ 28Setting Up Custom Barcodes.................................................................. 31Navigating the Data Entry Screen .......................................................... 32The Virtual Keyboard ............................................................................. 33NITON Lead paint Test Platform........................................................... 34NITON RCRA Verification Response Sample ...................................... 35Certified values for NIST standards ....................................................... 36

  • PRECIOUS METALS MODE ........................................................... 1Using Precious Metals Mode.................................................................. 1

    ROUTINE MAINTENANCE GUIDELINES ........................................ 1Battery Pack and Battery Charger .......................................................... 1Maintenance, Cleaning and Repairs ....................................................... 6Storing and Transporting Your NITON XLp 300A/700A Series Analyzer ............................................. 9

    APPENDIX A ................................................................................. IX-ray Emission Energies, Arranged by Element, by Atomic Number... i

    APPENDIX B.................................................................................. IIIX-ray Emission Energies Arranged Alphabetically by Element ............ iii

    APPENDIX C.................................................................................. VSpectraView............................................................................................ v

    APPENDIX D: ................................................................................ VIIIAPPENDIX E:................................................................................. XIIAPPENDIX F: ................................................................................. XV

    Appendix G: Warranty ........................................................................... xvi

  • Introduction:YourNITONXRFAnalyzerIntroduction YOUR NITON XRF ANALYZER

    UNPACKING AND ASSEMBLING YOUR NITON XLP XRF ANALYZER

    Inspect the shipping carton for signs of damage such as crushed or water damaged packaging. Immediately notify the shipping company and Thermo Electron Corporation, in the United States, toll free, at (800) 875-1578, or outside the United States, at +1-978-670-7460, if there is any visible damage to the ship-ping container or any of its contents.

    Open the packing carton. If your instrument is not packed in its carrying case, please call Thermo Electron Corporation imme-diately, in the United States, toll free, at (800) 875-1578, or out-side the United States, at +1-978-670-7460.

    Verify the contents of the shipping container against the enclosed packing list. If there are any discrepancies between the actual contents of the shipping container and the enclosed pack-ing list, please notify Thermo Electron Corporation immedi-ately, in the United States, toll free, at (800) 875-1578, or outside the United States, at +1-978-670-7460.

    Open the carrying case and visually inspect the instrument for damage before removing it from the case. Call the shipper and Thermo Electron Corporation if you find any damage to the case or its contents.

    Save the shipping carton and all packing materials. Store them in a safe, dry area for reuse the next time that you ship the instrument. NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideIntroductioni

  • Introduction:YourNITONXRFAnalyzerTHE NITON XLP XRF ANALYZER OVERVIEW

    The NITON XLp Analyzer is a single unit, hand held, high perfor-mance portable x-ray fluorescence (XRF) elemental analyzer.

    THE CONTROL PANEL

    The control panel is located on the instruments top housing, directly below the LCD touch screen (see Figure I-2). The control panel consists of a 4 way touch pad and two control buttons, one on each side. Using either the control panel or the touch screen (with or without the NITON standard touch screen stylus accessory, that clips in the XLp battery pack) you may navigate through all of the instruments screens and menus. You can control the movement of the screen cursor by pressing the four way control pad in one of four directions to highlight each of the menu options. The enter but-ton on the right side of the four way touch pad is used to select highlighted menu options. The on/off/escape button both controls the power to the instrument and serves as an "escape" button. When the on/off/escape button is pushed and immediately released, it

    Top View

    Rear View Front View

    Bottom View

    Side View

    Control panel

    Stylus

    LED lights Trigger

    LCD touch screen

    Measurement window

    Battery pack/handle

    Figure I-1

    Proximity Sensor

    RearInterlock

    NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideIntroductionii

  • Introduction:YourNITONXRFAnalyzerfunctions as an "escape", and brings you back to the Main Menu from the current screen in the menu system.

    Push and hold the on/off/escape button for at least 3 seconds to turn the instrument on. A 'beep' will sound as the power comes on. Push the on/off/escape button and hold it down for about 10 seconds to shut off power to the instrument from any screen in the menu sys-tem. The instrument will 'beep' as it shuts down.

    You also have the option of operating the instrument, including navigating the menu system, by using the built in touch screen with or without the stylus. To select a menu option with the stylus, tap on the icon once. The touch screen icons have the same functionality as the four way touch pad, the on/off/escape button, and the enter button. This User's Guide will refer to the process of choosing a course of action by selecting an icon from a menu, either using the touch screen or using the control panel buttons, as selecting.

    Selecting the Return icon works everywhere throughout the User Interface to bring you back to the previous menu from the current menu in the menu system. Use the on/off/escape button to return to the Main Menu.

    LCD touch screen

    On/off/escape button

    Clear/enter button

    4-way touch pad

    Figure I-2NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideIntroductioniii

  • Introduction:YourNITONXRFAnalyzerINSTRUMENT STARTUP

    To turn on the instrument, depress the on/off/escape button on the control panel for approximately 3 seconds, until you hear a beep.

    On startup, the screen will be replaced by a Restart screen (see Fig-ure I-3) which will automatically count down from 9 to 0 in incre-ments of one second.

    When the Restart is complete, the Restart Screen will be replaced by the Logon screen (see Figure I-4). Tap anywhere on this screen to access the virtual touch pad:

    Figure I-3

    Figure I-4NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideIntroductioniv

  • Introduction:YourNITONXRFAnalyzerSelect your 4 digit security code, followed by the enter (E) key. The temporary password assigned by default is 1-2-3-4, followed by the E key. After you have completed the log on procedure, the word "SUCCESS" will appear on the bottom of the screen, then the Main Menu will appear:

    Check the date/time. The time should be set correctly for accurate and verifiable record keeping (see Set Time and Date on page 2-7).

    Your analyzer can be stored safely in temperatures of up to 122F (50C) and is designed to operate at temperatures of up to 122F (50C). You will not be able to take a measurement if the instrument overheats. If it is hot to the touch, you should allow it to cool before testing.

    Figure I-5NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideIntroductionv

  • Introduction:YourNITONXRFAnalyzerSCREEN CONTRAST

    To adjust the contrast of your instruments touch screen display, press and hold the left and right ends of the 4 way Touch Pad until a beep sounds. After the beep, you may press the up portion of the 4 way Touch Pad to darken the screen, and the down portion to lighten the screen. When you have the display adjusted so that it is best for you, press the Enter button to save the current setting. NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideIntroductionvi

  • Chapter1:RadiationSafetyChapter 1 RADIATION SAFETY

    The NITON XLp Analyzer was designed so that virtually no mea-surable radiation external to any part of the instrument can escape when the shutter is closed. When the instrument is used in accor-dance with it's instructions, it is completely safe, that is, there is minimal radiation exposure, even with the shutter open.

    NITON XLp 300A/700A Series Analyzers contain a sealed 109Cd radioactive isotope source. The source is designed to remain secure even under extreme conditions, so that even if the instrument is bro-ken, crushed or burned, there should be no leakage of radioactive material.

    During manufacturing, each sealed isotope source is locked in place in a solid tungsten alloy source holder. The source is completely secure in its housing because the aperture at the closure end of the housing is smaller than the source and is completely sealed. The source assembly is secured in the instruments case, which is fitted with tamper-proof screws.

    Your exposure to radiation is determined by three factors: time, dis-tance, and shielding. Human exposure to radiation is typically mea-sured in rems, or in one-thousandths of a rem, called millirems (mrem).

    For a given source of radiation, three factors will determine the radiation dosage you receive from the source:

    1. Duration of ExposureThe longer you are exposed to a source of radiation the more radiation strikes your body and the greater the dose you receive. Dosage increases in direct proportion to length of exposure.

    2. Distance from The SourceThe closer you are to a source of radiation, the more radiation strikes you. The dosage increases in inverse-squared relation to your distance from the source of radiation. For example, the radiation dose one inch from a source is nine times greater than NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter11

  • Chapter1:RadiationSafetythe dose three inches from the source, and 144 times greater than the dose one foot (12 inches) from the source. For another example, the radiation dose one meter from the source of radia-tion is 100 times lower than the dose at 10 cm from the source of radiation. Keep your hand and all body parts away from the front end of the instrument when the shutter is open to minimize your exposure.

    3. ShieldingYour instrument emits virtually no radiation with the shutter closed because the 109Cd source is thoroughly shielded in every direction. This shielding absorbs nearly all of the radiation produced by the source except when the shutter is open during testing. With the shutter open, the instrument emits a conical primary beam (see Fig-ure 1.1) of radiation out the front of the device. This beam is mostly absorbed by sample in a typical measurement. Without a sample, the in-beam dose rate is approximately 315 mrem at a 5cm distance distance from the front of the device.

    Note: Wearing a dosimeter badge does not protect you against radia-tion exposure. A dosimeter badge measures your exposure.

    Note: Pregnant workers may want to take special precautions to reduce their exposure to radiation. Qualified scientists have recom-mended that the radiation dose to pregnant women should not exceed a total of 500 mrem/gestation period. See U.S. NRC Regulatory Guide 8.13 "Instruction Concerning Prenatal Radiation Exposure".

    The Table 1-1 lists typical radiation doses encountered in daily life and lists the annual occupational radiation dosage limits for adults set forth in 105CMR 120.200NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter12

  • Chapter1:RadiationSafetyTYPICAL RADIATION DOSES IN MILLIREM (NCRP, 1987)

    Table 1-1

    Average total dose in US (annual) 360 mrem (3.6 mSv)

    Average worker exposure (annual) 210 mrem (2.1 mSv)

    Average exposure for underground miner (annual)

    400 mrem (4.0 mSv)

    Exposure for airline crew (1,000 hours at 35,000 ft)

    500 mrem (5.0 mSv)

    Additional from living in Denver at 5300' (annual)

    25 mrem (0.25 mSv)

    Additional from 4 pCi/l radon in home (annual)

    1,000 mrem (10.0 mSv)

    Typical chest x-ray 6 mrem (0.06 mSv)

    Typical head or neck x-ray 20 mrem (0.2 mSv)

    Typical pelvis/hip x-ray 65 mrem (0.65 mSv)

    Typical lumbar spine x-ray 30 mrem (1.3 mSv)

    Typical upper G.I. x-ray 245 mrem (2.45 mSv)

    Typical barium enema x-ray 405 mrem (4.05 mSv)

    Typical CAT scan 110 mrem (1.10 mSv)

    Minimum detectable dose on a standard film badge

    5 mrem/QTR (0.05 mSv)

    Annual occupational dosage limits:

    Maximum allowable for the gen-eral public (annual)

    100 mrem (1.0 mSv)

    Annual Occupational Dose Limits for Adults:

    Whole body 5,000 mrem/yr (50 mSv)

    For a pregnant worker (during ges-tation period)

    500 mrem (5.0 mSv)

    For a minor 500 mrem (5.0 mSv)

    Eye dose equivalent 15,000 mrem (150 mSv)

    Shallow dose equivalent to the skin or any extremity or organ

    50,000 mrem (500 mSv)NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter13

  • Chapter1:RadiationSafetyAs noted above, the allowable limit in the U.S. for occupational exposure is 5,000 mrem/year (50 mSv/year) for a whole-body and 50,000 mrem (500 mSv) for shallow penetration and extremities. Extremity exposure from a properly used NITON XRF instrument will be less than 100 mrem per year, (1.0 mSv per year) even if the instrument is used as much as 2,000 hours per year, with the shutter open continuously.

    NOTE: NCRP is the National Council on Radiation Protection and Mea-surementsNITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter14

  • Chapter1:RadiationSafetyHOW TO USE YOUR NITON XLp

    The NITON XLp was designed to be as safe as possible. However, we strongly recommend that you follow these precautions to insure your safety and the safety of those around you.

    WARNING!

    Always be aware of the location of your instruments radioac-tive sources and the direction of their beam of X-rays. The loca-tion of the sources is at the front end of the instrument.

    Open the shutter only to do a test. The shutter can only be opened after the user has logged on to the instrument using the password.

    During testing, a strong beam of radiation is continuously emitted through the kapton window at the front of the instrument (see Fig-ure 1-1). There will be some radiation at the front and top-front of the instrument. There is negligible radiation at the handle of the instrument.

    !

    Horizontal reference

    55

    Figure 1-1

    x-raybeamNITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter15

  • Chapter1:RadiationSafetyWARNING!

    Always treat radiation with respect. Do not hold your instru-ment near the Kapton window during testing. Never point your instrument at yourself or anyone else when the shutter is open.!NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter16

  • Chapter1:RadiationSafety SHUTTER SAFETY

    Under no circumstances should the shutter be open when theinstrument is not in use!!!

    The 3 warning lights on your instrument will go on when the shut-ter is open and stay on as long as the shutter remains open.

    WARNING!

    In the unlikely event that the shutter becomes stuck in the open position, remove the battery (see Battery Pack and Battery Charger - Routine Maintenance Guidelines - Note: All shutters will close immediately and remain locked in the closed position when the battery pack is not attached to the instrument), replace the instrument in its shielded holster, place the holster in the shielded carrying case, and call Thermo Electron Corpo-rations Service Department at (800) 875-1578 or +1-978-670-7460.

    WARNING!

    If your LCD Touch Screen displays the message SHUTTER DOES NOT OPERATE, remove the battery (see Battery Pack and Battery Charger - Routine Maintenance Guidelines - Note: All shutters should close immediately and remain locked in the closed position when the battery pack is not attached to the instrument), replace the instrument in its shielded holster, place the holster in the shielded carrying case, and call Thermo Elec-tron Corporations Service Department at (800) 875-1578 or +1-978-670-7460.

    !

    !NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter17

  • Chapter1:RadiationSafetyMONITORING YOUR RADIATION EXPOSURE

    There is virtually no measurable radiation from a NITON XLp ana-lyzer when its shutters are closed. The maximum dosage to which you are exposed when properly operating your NITON XLp is

  • Chapter1:RadiationSafetyThe diagram in Figure 1-2 shows the test wipe locations.

    The source shutter must be closed while performing a leak test!

    Along these seams

    Around these screw heads

    Along these seams

    Around thesescrew heads

    Along these seams

    Around thesescrew heads

    Figure 1-2NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter19

  • Chapter1:RadiationSafetyThe following laboratories supply leak test kits:

    Applied Health Physics2986 Industrial Blvd.Bethel Park, PA 15102Tel: (412) 835-9555

    Stan A. Huber Consultants200 N. Cedar RoadNew Lennox, IL 60451Tel: (800) 383-0468

    Valley Safety Services330 Old Enfield RoadBelchertown, MA 01007Tel: (413) 323-9571

    These companies are listed for information purposes only. NITON does not endorse the services of these companies. Please check with your local NITON representative if you are located outside the USA.NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter110

  • Chapter1:RadiationSafetyPROCEDURES FOR INSTRUMENT LOSS OR DAMAGE IN THE USA

    If your instrument is damaged, destroyed, lost, or stolen, call:

    1. The Office of Radiological Safety for your states Dept. of Health.

    Telephone:___________________________________

    2. Ken Martin, C.I.H of Thermo Electron Corporation.

    3. If your instrument is lost, stolen, or damaged in a car accident, also, immediately notify your State Police Department:

    Telephone: ___________________________________

    If your instrument is damaged in a fire or an explosion, also immediately, notify your local Fire Department.

    Telephone:___________________________________

    Note: Please fill in the phone numbers on these pages today. Keep copies where you can find them in case of an emergency.

    Table 1-2: During Regular Business Hours

    Calling from within the USA (800) 875-1578(toll-free)

    Calling from outside the USA +1-978-670-7460

    Table 1-3: During Evenings and Weekends

    CALL ONLY WHEN YOU HAVE A RADIOLOGICAL EMERGENCY

    Person Phone NumberMobile Phone

    Number

    Calling from Any-where

    Ken Martin +1 (617) 923-6312 +1 (617) 901-3125NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter111

  • Chapter1:RadiationSafetyPROCEDURES FOR INSTRUMENT LOSS OR DAMAGE OUTSIDE THE USA

    If your instrument is damaged, destroyed, lost, or stolen, immedi-ately notify:

    1. The proper authorities for your location.

    Telephone:___________________________________2. Ken Martin, C.I.H. of Thermo Electron Corporation

    3. If your instrument is lost, or stolen, or damaged in a car acci-dent, also, immediately notify your local Police Department:

    Telephone: ___________________________________

    If your instrument is damaged in a fire or an explosion, also immediately, notify your local Fire Department.

    Telephone:___________________________________

    Note: Please fill in the phone numbers on these pages today. Keep copies where you can find them in case of an emergency.

    Table 1-4: During Regular Business Hours

    Calling from within the USA (800) 875-1578(toll-free)

    Calling from outside the USA +1-978-670-7460

    Table 1-3: During Evenings and Weekends

    CALL ONLY WHEN YOU HAVE A RADIOLOGICAL EMERGENCY

    Person Phone NumberMobile Phone

    Number

    Calling from Any-where

    Ken Martin +1 (617) 923-6312 +1 (617) 901-3125NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter112

  • Chapter1:RadiationSafetyXLp RADIATION DOSE PROFILE - WOOD SUBSTRATE

    XLp 300A/700A Series In-Beam Dose Rates - Shutter Open

    Notes:Not to scale.

    Profile conducted by: James Blute, CHP, Corporate RSO, 04/05/04.

    Substrate 3/4 thick pine.

    Profile was taken with the strongest source and the least dense sub-strate to show the worst case scenario. Any other combination of source strength and substrate would result in lower dose rates from scatter radiation.

    Isotope Activity 5 cm 30cm 100 cm Trigger

    Cd-109 50 369 14.8 1.71 0.053

    0.092mr/hr@30cm (0.92 Sv/hr)

    0.092mr/hr@30cm (0.92 Sv/hr)

    0.079mr/hr@30cm (0.79 Sv/hr)

    2.64mr/hr@5cm (26.4 Sv/hr)

    0.092mr/hr@30cm (0.92 Sv/hr)

    2.37mr/hr@5cm (23.7 Sv/hr)

    2.24mr/hr@5cm (22.4 Sv/hr)

    0.066mr/hr@30cm (0.66 Sv/hr)

    0.857mr/hr@5cm (8.57 Sv/hr)

    0.079mr/hr@30cm (0.79 Sv/hr)

    0.04mr/hr@30cm (0.4 Sv/hr)

    0.066mr/hr@30cm (0.66 Sv/hr)

    Figure 1-3

    2.51mr/hr@5cm (25.1 Sv/hr) 2.24mr/hr@5cm (22.4 Sv/hr)

    1.45mr/hr@5cm (14.5 Sv/hr)1.45mr/hr@5cm (14.5 Sv/hr)NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter113

  • Chapter1:RadiationSafetyView of the Underside of the XLp Analyzer Showing Proper Placement of General and State Specific Radiation Labels

    Figure 1-5NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter114

  • Chapter2:TheMenuSystemChapter 2

    THE MENU SYSTEM

    The NITON XLp Menu System enables you to perform critical tasks, including taking readings and viewing and moving data, with a minimum number of steps. Menus are presented as small pictures called icons which, when selected, will do one of three things:

    1. Toggle between two different functions or views, such as turn-ing backlighting on or off.

    2. Present a subsidiary or sub-menu which will allow you access to more choices.

    3. Present a screen which allows you to view data, edit data, or control the instrument.

    Icons which appear on your NITON instrument screen display in light gray (grayed out) represent features which are not enabled, and therefore cannot be selected. In order to enable features on your NITON instrument which are currently not enabled, please contact Thermo Electron Corporation in the United States, toll free, at (800) 875-1578, or outside the United States, at +1-978-670-7460, or your local Authorized NITON Service Center.

    Icons which appear on your NITON instrument screen display with a diagonal line through them represent features which are currently turned off. When an icon with a diagonal line through it is selected, the diagonal line through that icon will automatically be erased, and the feature corresponding to that icon will automatically become enabled.NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter21

  • Chapter2:TheMenuSystemTHE MAIN MENU

    All NITON XLp instruments functions are accessible from the Main Menu and subsidiary menus. Each of the instrument func-tions represented by an icon on the Main Menu screen (Test, Mode, Utilities, Data, and Common Setup) may be selected by choosing the appropriate icon. When one of these Main Menu icons is selected, the function specific sub-menu appropriate to that icon will be displayed.

    In order to test samples in the previously used test mode, simply select the Test icon. Your NITON XLp analyzer will operate in the testing mode that is currently selected. Choose an appropriate test mode for the samples you are testing by selecting a mode from the Mode Menu.

    Access the Mode Menu by selecting the Mode icon from the Main Menu screen. The instrument will remember the last mode used on the instrument, and will use that mode by default unless another mode is selected.

    Access the Utilities Menu by selecting the Utilities icon from the Main Menu screen. The Utilities Menu enables you to view instrument specifications; set the date and time; auto-calibrate the instrument electronics and the touch screen display; and update and maintain entry passwords and user profiles.

    Figure 2-1NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter22

  • Chapter2:TheMenuSystemAccess the Data Menu by selecting the Data icon from the Main Menu screen. The Data Menu allows you to view readings, and allows you to view the alloy library and stored signatures.

    Access the Common Setup Menu by selecting the Common Setup icon from the Main Menu screen. The Common Setup Menu allows you to turn on or off the liquid crystal display back-light, turn on or off the integrated bar code scan engine, to enable and configure source utilization, and to enable or disable the printer.

    Return to the Logon screen by selecting the Logoff icon. The Logon Screen logs you out and allows you to login again, prevent-ing casual unauthorized access to your analyzer.NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter23

  • Chapter2:TheMenuSystemTHE MODE MENU

    The Mode Menu enables you to select any one of the sample test modes that have been installed on your NITON XLp analyzer.

    Select the Alloy icon to access any one of the alloy testing modes. The Alloy Modes enables you to test metal alloys for chemical composition and/or alloy identification. The Alloy Testing Modes are detailed in Chapter 3 of this User's Guide.

    The Pb Paint Mode allows you to determine lead (Pb) loading in paint samples in units of mg/cm2, and to determine if paint samples are above or below the user-defined action level for lead in the shortest time possible. The Pb Paint Mode is detailed in chapter 4 of this Users Guide.

    Select the Thin Sample Mode icon to access the Thin Sample Mode Menu, where you may choose a thin sample testing mode appropriate to the samples you will be testing. The Thin Sample Testing Modes allow you to analyze thin samples, such as dust wipes and air filters, and coatings for elemental analysis. The Thin Sample Test Modes are detailed in Chapter 5 of this User's Guide.

    Figure 2-2NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter24

  • Chapter2:TheMenuSystemSelect the Bulk Sample Mode icon to access Bulk Sample Mode. The Bulk Sample Mode allows you to analyze soil, mining, and other thick samples for metallic composition and/or contamination. The Bulk Sample Mode is detailed in Chapter 6 of this Users Guide.

    Select the User Definable Mode icon to access User Definable Mode. The User Definable Mode allows you to create your own protocols and methods for your own use. The User Definable Mode is detailed in Chapter 7 of this Users Guide.NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter25

  • Chapter2:TheMenuSystemTHE UTILITIES MENU

    To access the Utilities Menu, select the Utilities icon from the Main Menu display. The Utilities Menu enables you to view your NITON instrument specifications, set the date and time, auto-cali-brate your NITON's detector or touch screen display, Rotate the dis-play on the LCD screen, or change the communication (baud) rate for the RS-232 port.

    Select the Calibrate icon to access the Calibrate Menu. The Cali-brate Menu allows you to calibrate the detector or to calibrate the touch screen.

    Select the Specs icon to display the instrument's specifications. These specifications include your NITON XLp's serial number, software and firmware versions, temperature, bias, and data copro-cessors. Press the enter button to return to the Utilities Menu.

    Figure 2-3NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter26

  • Chapter2:TheMenuSystemSelect the Date & Time icon to set the date and time as needed for different time zones, daylight savings time, or any other reason. The date and time are factory preset prior to shipping. The format used is month/day/year - MM/DD/YY, and hour/minute - HH/MM, for the 24 hour clock.

    When the Date & Time icon is selected, the Date & Time screen comes up on your XLp's LCD Screen. Initially, the first character of the month is highlighted in reverse video (white on black), as in the sample display shown here. To change a character, select the digit you want to replace the character with from the virtual numeric keypad displayed on the screen, then select the Enter (E) character from the virtual numeric keypad. Your NITON XLp will then accept the entry and automatically advance to the next digit. To skip a character, simply select the Enter (E) character from the virtual numeric keypad without selecting a replacement character.

    For example, on the sample display, if you wish to change the "06" of the month to "07", the display appears with the first character (0) highlighted. Select the Enter (E) character to skip the zero. The "6" will now be highlighted. Select the "7" digit from the virtual numeric keypad, then select the Enter (E) key from the virtual numeric keypad. The change is accepted and the next digit is high-lighted. Continue to select the Enter (E) symbol from the virtual numeric keypad to skip over the remaining characters of the date and time until the last character is reached. When you select the Enter (E) key from the virtual numeric keypad to confirm the last

    Numeric keypad

    Highlighted numeral

    TimeDate

    Figure 2-4NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter27

  • Chapter2:TheMenuSystemcharacter, the word "SUCCESS" will appear beneath the Date field, and you will be returned to the Main Menu. The date is given in month/day/year format.

    Caution

    Your XLp analyzer must have the correct time and date set in order to test samples correctly using the 109Cd radioisotope source. Please make sure that the time and date are set correctly before testing.

    WARNING!

    It is important that the date and time information displayed on the Date and Time screen is correct. If either the date or time is incorrect, the information stored with your readings will be incorrect. In addition, an incorrect date prevents the instrument from properly compensating for normal source decay - causing erroneous analysis results for instruments equipped with 109Cd. This information must be correct before proceeding with testing.

    The instrument will automatically return you to the Main Menu when the entry is complete.

    Select the Current Baud Rate icon to change the communications rate for the RS-232 port. Selecting the Current Baud Rate icon will toggle the communications rate between 115 kbaud and 38 kbaud. The default 115 kbaud rate may be too fast for some older computers, and dropping the rate to 38 kbaud will insure proper communications between your PC and your NITON XLp Analyzer.

    Select the Rotate Screen icon to toggle the orientation of the screen between right side up and upside down. This is used primarily when your analyzer is placed in the NITON Environmental Test Stand, because the analyzer is inverted when properly installed in the Test Stand.

    !

    !NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter28

  • Chapter2:TheMenuSystem THE DATA MENU

    To access the Data Menu, select the Data icon from the Main Menu display. The Data Menu enables you to access readings and libraries, for viewing or manipulation.

    Select the View Data icon in order to view previously taken test result readings. When the View Data icon is selected, the Results screen of your most recent test is shown on the LCD display.

    Using the buttons on the control panel, you may view different readings or additional data for different readings. Pressing the "Up" position on the 4-way touch pad of your NITON XLp 300 Series Lead-based-Paint Analyzer will display the standard screen analysis. Pressing the "Down" position on the 4-way touch pad will display a

    Figure 2-5a

    Figure 2-6NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter29

  • Chapter2:TheMenuSystemcomplete scrolling elemental chemistry listing. Each press of the Down position scrolls the screen down to the next element. Press-ing the "Left" position on the 4-way touch pad of your NITON 300 Series Lead-based-Paint Analyzer will display the previous read-ing, or if the first reading is currently displayed, the last reading. Pressing the "Right" position on the 4-way touch pad will display the next reading, or if the last reading is currently displayed, the first reading. The NITON XLp 300 Series Lead-based-Paint Analyzer can store up to 3000 readings.

    You can also look at the complete x-ray spectra for each reading stored in your NITON XLp 300 Series Lead-based-Paint Analyzer's memory.

    For any reading result, simply use the on/off/escape button to gain access to the screen buttons at the bottom of the screen. Selecting RETN (Return) will take you to the previous menu. Selecting DATA will show the Data Entry parameters for the Reading. Selecting SPTR (Spectrum) will show a graphed spectrum of this reading, called SpectraView. SpectraView can be a useful tool for rapid, qualitative analysis of sample chemistries. See Appendix C: SpectraView for details.

    Pressing the DATA screen button while viewing the reading spec-trum will access the parameter data for the reading. In this scrolling screen, you can see the parameters input into the Data Entry Screen describing the conditions of the reading test target, the inspector taking the reading, and other data concerning the reading.

    Select the Erase icon to access the Erase Menu. The Erase Menu allows you to erase your data.

    Figure 2-7NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter210

  • Chapter2:TheMenuSystem Caution

    Never turn off the instrument while data is being erased!

    WARNING!

    Do not attempt to take measurements while downloading read-ings! This will generate an error requiring a system reset, and may corrupt your stored readings, requiring all stored readings to be erased.

    Select the Return screen button or use the on/off/escape button to the left of the four-way touch pad to return you to the Main Menu.

    Select the View Libraries icon to access the Library View Menu. The Library View Menu allows you to view data in the Grade Library as well as the Superlib and Superstds libraries.

    Select the View Signatures icon to view data saved as reference sample signatures in Signature ID Mode. When the View Data icon is selected, the Results screen of your most recent test is shown on the LCD display.

    Select the More icon to access the second page of the Data Menu.

    !

    !NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter211

  • Chapter2:TheMenuSystemTHE DATA MENU - SECOND PAGE

    To access the Data Menu Second Page, select the More icon from the Data Menu display. The Data Menu enables you to access readings and libraries, for viewing or deleting.

    Select the View SuperChem icon in order to view your SuperChem data. The SuperChem View icon allows you to view your SuperChem Mode data, and also allows you to delete indi-vidual readings.When the View Data icon is selected, the Results screen of your most recent test is shown on the LCD display.

    Select the View SuperPrec icon in order to view your SuperPrec data. The View SuperPrec icon allows you to view your Super-Prec Mode data, and also allows you to delete individual SuperChem standards.When the View Data icon is selected, the Results screen of your most recent test is shown on the LCD dis-play.

    Figure 2-5bNITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter212

  • Chapter2:TheMenuSystemTHE VIEW LIBRARIES MENU

    To access the View Libraries Menu, select the View Libraries icon from the Data Menu. The View Libraries Menu enables you to view reference data from your analyzers libraries.

    Select the View Grade Library icon to view your Grade Library, which is set by NITON. The entries in the Grade Library serve as a reference for chemistry based analysis. The library entries allow the analyzer to work properly out of the box without needing time-consuming pre-analysis. Please refer to the NDT User Guide for information on modifying the Grade Library.

    Select the View SuperStds icon in order to view your SuperStds Alloy library.

    Select the View Additional Library icon in order to view your Additional Library alloys, which you may have uploaded to your XLp Analyzer with the NDTl utility. If you have not uploaded an additional library, the View Additional Library icon will be grayed-out and the View Additional Library function will be unavailable.

    Figure 2-8NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter213

  • Chapter2:TheMenuSystemTHE COMMON SETUP MENU

    To access the Common Setup Menu, select the Common Setup icon from the Main Menu display. The Common Setup Menu gives you access to various NITON XLp instrument functions, including touch screen display backlighting and the built in bar code scanner, and enables you to configure the way the sources contained in your NITON XLp analyzer are used in sample testing.

    Select the Hardware Setup icon to access the Hardware Setup menu. The Hardware Setup Menu allows you to toggle the dis-play backlight on or off, toggle the built-in bar code scanner on or off, set up the analyzer to use a welding mask, or access the Hot-foot Mode.

    Select the Set Protocol icon to bring up the Set Protocol menu. The Set Protocol Menu allows you to control source utilization by enabling and disabling individual sources, set the time between source autoswitching, and control the match number triggering source autoswitching.

    Select the Set Cal Factors (Ind Bulk) icon to bring up the Set Cal Factors Menu. The Set Cal Factors Menu allows you to correct for the presence of certain light elements in a Bulk Mode test matrix which may influence the readings, even though they are not quanti-fied by the analyzer.

    Select the Serial Output icon to access the Serial Output Menu. The Serial Output Menu allows you to download data across a

    Figure 2-9NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter214

  • Chapter2:TheMenuSystemserial line or a Bluetooth wireless connection from your instrument to a computer, printer, or other computing device.NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter215

  • Chapter2:TheMenuSystemTHE CALIBRATE MENU

    To access the Calibrate Menu, select the Calibrate icon from the Utilities Menu. The Calibrate Menu enables you to re-calibrate the instrument's touch screen display interface and to automatically re-calibrate your instrument's sample analysis electronics.

    Select the Calibrate Detector icon to re-calibrate the instrument's electronics. As soon as the icon is selected, calibration will begin. The instrument is programmed to calibrate for a specific, predeter-mined period in order to ensure proper operation of your NITON XLp analyzer in the field. The instrument calibration screen will be displayed until calibration is complete. After the calibration has fin-ished, the calibration results will be displayed. Press the on/off/escape button or the Return icon to return to the Main Menu. In order to insure good test results, it is essential that you calibrate your NITON XLp 300 Series Lead-based-Paint Analyzer's detector if a check sample test reveals discrepancies in the reading.

    Select the Calibrate Touch Screen icon to re-calibrate the instru-ment's touch screen display. This procedure establishes the display boundaries for the touch screen interface. When the Calibrate Touch Screen icon is selected, the display will show the message: "Calibrate Touch Screen". There will be a small cross in the upper left-hand corner of the display. Tap on this cross with the stylus, and the cross will disappear and reappear in the lower left-hand corner of the screen. Tap on the cross again, and it will reappear in the lower right-hand corner of the screen. Tap on the cross again and it will reappear in the top right-hand corner of the screen. Tap on the

    Figure 2-10NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter216

  • Chapter2:TheMenuSystemcross once more, and the Logon Screen will appear. Logon as nor-mal, and you will be presented with the Main Menu

    Figure 2-11NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter217

  • Chapter2:TheMenuSystemTHE ERASE MENU

    To access the Erase Menu, select the Erase icon from the Data Menu. The Erase Menu enables you to delete data from your ana-lyzer, allowing you to gain storage space for more recent data. You should only erase data which you have already transferred to per-manent storage, or when requested to do so by NITON service per-sonnel.

    Select the Erase All Data icon to erase all data, including signa-tures and SuperChem reference readings, from your analyzer. Selecting the Erase All Data icon will bring up a confirmation screen (see Figure 2-13) asking you Are you sure? with options to select YES or NO. Selecting YES will erase all reading data from your analyzer. Selecting NO will return you to the Erase Menu.

    Select the Erase Readings icon to erase all accumulated test read-ings from your analyzer. Selecting the Erase Readings icon will bring up a confirmation screen (see Figure 2-13) asking you Are you sure? with options to select YES or NO. Selecting YES will erase all test reading data from your analyzer. Selecting NO will return you to the Erase Menu.

    Select the Erase Signatures icon to erase all accumulated alloy sig-natures from your analyzer. Selecting the Erase Signatures icon will bring up a confirmation screen (see Figure 2-13) asking you Are you sure? with options to select YES or NO. Selecting YES will erase all signature data from your analyzer. Selecting NO will return you to the Erase Menu.

    Figure 2-12NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter218

  • Chapter2:TheMenuSystemSelect the Erase SuperChem icon to erase accumulated SuperChem reference readings from your analyzer. Selecting the Erase SuperChem icon will bring up a confirmation screen (see Figure 2-13) asking you Are you sure? with options to select YES or NO. Selecting YES will erase all SuperChem refer-ence reading data from your analyzer. Selecting NO will return you to the Erase Menu.

    Figure 2-13NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter219

  • Chapter2:TheMenuSystemTHE SERIAL OUTPUT MENU

    Select the Download Regions icon to toggle the configuration of the serial port to the task of exporting Regions data to your com-puter.

    Select the Download Spectra icon to toggle the configuration of the serial port to the task of exporting Spectral data to your com-puter.

    Select the Printer icon to toggle the configuration of the serial port to the task of sending your data to the printer. Enabling the Printer icon will disable Live Serial Output.

    Select the Live Serial Output icon to toggle the serial post to the task of sending continuous data updates to an external device. Live Serial Output is very useful for online applications with continuous monitoring of a product stream. Enabling Live Serial Output icon will disable the Printer.

    Figure 2-14NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter220

  • Chapter2:TheMenuSystemTHE SET PROTOCOL MENU

    For NITON XLp analyzers equipped with more than one radioiso-tope source, the Set Protocol Menu enables you to directly enable or disable any source, control the time that a source irradiates the sample before auto-switching to another source, and select the chi-squared deviation cutoff for auto-switching between sources.

    Select the Enable Sources icon from the Set Protocol Menu to bring up the Source Menu. From the Source Menu, you may choose exactly which of the sources contained in your NITON XLp analyzer will be used for sample testing.

    Select the Source Switch on Time Only icon from the Set Proto-col Menu to toggle Time Switch Only Mode on or off. In Time Switch Only Mode, the NITON XLp analyzer will ignore the match number and only switch sources according to the time inter-val you set in the Source Auto-Switch Time menu.

    Select the Source Auto-Switch Time icon from the Set Protocol Menu to display the Source Time Menu. The Source Time Menu enables you to set the number of seconds each enabled source is allotted before auto-switching will occur when needed during sam-ple testing. Your NITON XLp analyzer will auto-switch from one source to another when the testing time for that source is greater than or equal to the time you have chosen, the match number for that source is lower than the match number you have set, and the

    Figure 2-15NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter221

  • Chapter2:TheMenuSystemidentified alloy is flagged as needing the switch in the NITON Alloy Library.

    Select the Source Auto-switch Match Num. icon from the Set Protocol Menu to display the Source Match Menu. The Source Match Menu enables you to set the chi-squared deviation (match number) below which the instrument will auto-switch to the next enabled source during alloy sample testing.

    Select the Set Maximum Measurement Time icon from the Set Protocol Menu to display the Max Time Screen. The Max Time Screen allows you to set a cap on the maximum time any sample is allowed to be analyzed. This allows you to set up a sample in a NITON Test Stand for a reading without having to time the reading manually. In the field, the maximum measurement time feature also allows you to control measurement time in noisy or otherwise dis-tracting environments.

    The Max Time Screen displays a virtual touchpad, similar to the ones used for logging on and setting the clock. At the top left is the name of the screen. At the bottom left is the current measurement time in source seconds. Select C to clear the current maximum measurement time, then key in the time you want to use as a mea-surement cap with the number keys. Select E to enter the time, and the maximum measurement time will be reset to the new value.

    Figure 2-16NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter222

  • Chapter2:TheMenuSystemTHE HARDWARE SETUP MENU

    The Hardware Setup Menu enables you to toggle various options on or off, as well as select certain hardware dependant modes.

    Select the Backlight icon to toggle the built in touch screen display backlight off and on. Select the Backlight icon to turn the backlight off. The display will then show the Backlight icon with a slash through it. Select the Backlight icon with a slash through it to turn the backlight on. The display will then show the Backlight icon without a slash through it.

    Figure 2-17

    Backlight ON Backlight OFF

    Figure 2-18NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter223

  • Chapter2:TheMenuSystem Caution

    Enabling the backlight will reduce your battery pack operating time, requiring more frequent recharges.

    Select the Scan Engine icon from the Set Protocol Menu to toggle the Data Entry Screens on or off. If the Data Entry Screens are currently enabled, you can select the Scan Engine icon to disable data entry. The display will then show the Scan Engine icon with a slash through it. If the Data Entry Screens are currently disabled, you can select the Scan Engine icon to enable data entry. The dis-play will then show the Scan Engine icon without a slash through it.

    Select the Welding Mask icon from the Set Protocol Menu to adjust for the presence or absence of a welding mask. Welding Mask Mode requires additional hardware and special calibration. Welding Mask Mode should not be used without the welding mask hardware to ensure proper analysis, as the calibration adjusts to compensate for the changed geometry when using the welding mask. When the Welding Mask icon is displayed with a diagonal line through it, Welding Mask Mode is disabled. Selecting the Welding Mask icon will toggle Welding Mask Mode between an enabled state and a disabled state. When changing from Welding Mask Mode to normal use and back, remember to enable or disable Welding Mask Mode as appropriate.

    Some nations have laws or regulations which prohibit use of this feature. In this case, the feature will be disabled before shipping.

    Note: If the Welding Mask Icon is grayed out contact Thermo Electron Corporation or your local NITON Sales representative to have Welding Mask mode installed on your instrument.

    Select the Proximity Start Button icon from the Set Protocol Menu to toggle the use of the front proximity button. This enables the proximity button to be used to start taking a sample on contact. Selecting the Proximity Start Button icon again turns the proxim-ity button off.

    Some nations have laws or regulations which prohibit use of this feature. In this case, the feature will be disabled before shipping.

    !NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter224

  • Chapter2:TheMenuSystemTHE SOURCE MENU

    The Source Menu enables you to select exactly which sources will be activated during sample testing. Testing modes auto-switch between sources, based on the testing time and the match number parameters set for the instrument. You may disable a source if you know that the samples you are testing do not need that source for discrimination.

    Select the Enable Cd/Tube icon to toggle the 109Cd source x-ray tube between the enabled and disabled states. When the 109Cd source is disabled, the Enable Cd/Tube icon will appear on the Source Filter Menu display with a black diagonal line running through the icon. When the 109Cd source is enabled, there is no diagonal line through the icon.

    Select the Enable Fe55 icon to toggle the 55Fe source between the enabled and disabled states. When the 55Fe source is disabled, the Enable Fe55 icon will appear on the source display with a black diagonal line running through the icon. When the 55Fe source is enabled, there is no diagonal line through the icon.

    Selecting the Enable Am241 icon will toggle the 241Am source between the enabled and disabled states. When the 241Am source is disabled, the Am source icon will appear on the source display with a black diagonal line running through the icon. When the 241Am source is enabled, there is no diagonal line through the icon.

    Figure 2-19NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter225

  • Chapter2:TheMenuSystemTHE SOURCE TIME MENU

    Select the Source Autoswitch Match Time icon from the Set Pro-tocol Menu screen to display the Source Time Menu. Selecting appropriate icons from the Source Time Menu enables you to change the number of seconds that are allotted to each source before your NITON XLp analyzer auto-switches to the next source during sample testing.

    Your NITON XLp analyzer will auto-switch from one source to another when the testing time for that source is greater than or equal to the time you have chosen and the match number for that source is lower than the match number you have set.

    Select the Configure Cd109 icon to bring up the Source Time Configuration Screen for the 109Cd source. The Source Time Configuration Screen allows you to set the number of seconds the 109Cd source is used before auto-switching to the next enabled source during testing.

    Select the Configure Fe55 icon to bring up the Source Time Con-figuration Screen for the 55Fe source. The Source Time Configu-ration Screen allows you to set the number of seconds the 55Fe source is used before auto-switching to the next enabled source dur-ing testing.

    Figure 2-20NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter226

  • Chapter2:TheMenuSystemSelect the Configure Am241 icon to bring up the Source Time Configuration Screen for the 241Am source. The Source Time Configuration Screen allows you to set the number of seconds the 241Am source is used before auto-switching to the next enabled source during testing.

    The Source Time Configuration Screen enables you to select the number of seconds each source will be used during a sample analy-sis. In the center, the display screen is dominated by a virtual numeric keypad. At the bottom left of the screen is the number of seconds the selected source is allotted during testing (Example: 20.4.)

    To change the configuration for the selected source, clear the cur-rent number with the Clear key C, then change the number using the virtual numeric keypad, selecting the digits in order, then select enter (E). For example, to change the time from 20.4 seconds to 10.5 seconds: select C, then select "1", then select "0", then select ".", then select "5", then select "E". The source measurement time setting will be changed, and you will return to the previous menu.

    Current Mode

    Source seconds allotted

    Enterkey

    Clearkey

    Figure 2-21NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter227

  • Chapter2:TheMenuSystemTHE SOURCE MATCH NUMBER MENU

    Select the Source Autoswitch Match Number icon from the Set Protocol Menu screen to display the Source Match Number Menu. Selecting appropriate icons from the Source Match Num-ber Menu enables you to change the match number each source must reach before your NITON XLp analyzer auto-switches to the next source during sample testing.

    Your NITON XLp analyzer will auto-switch from one source to another when the match number for that source is lower than the match number you have chosen and the time for that source is greater than or equal to the time you have set.

    Select the Configure Cd109 icon to bring up the Source Match Number Configuration Screen for the 109Cd source. The Source Match Number Configuration Screen allows you to set the match number the 109Cd source is compared to before auto-switching to the next enabled source during testing.

    Select the Configure Fe55 icon to bring up the Source Match Number Configuration Screen for the 55Fe source. The Source Match Number Configuration Screen allows you to set the match number the 55Fe source is compared to before auto-switching to the next enabled source during testing.

    Figure 2-22NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter228

  • Chapter2:TheMenuSystemSelect the Configure Am241 icon to bring up the Source Time Configuration Screen for the 241Am source. The Source Time Configuration Screen allows you to set the match number the 241Am source is compared to before auto-switching to the next enabled source during testing.

    The Source Match Number Configuration Screen enables you to select the match number each source will be compared to during a sample analysis. The source being configured is displayed in the upper left hand corner of the screen display (Example: Fe55) along with the parameter being configured (Example: Time.) In the cen-ter, the display screen is dominated by a virtual numeric keypad. At the bottom left of the screen is the match number the selected source is to be compared to during testing (Example: 2.0).

    To change the configuration for the selected source, clear the cur-rent setting with the Clear key C, then change the number using the virtual numeric keypad, selecting the digits in order, then select enter (E). For example, to change the match number from 2.0 sec-onds to 3.0: select C, then select "3", then select ".", then select "0", then select "E". The source match number setting will be changed, and you will return to the previous menu.

    Current Mode

    Source match number

    Enterkey

    Clearkey

    Figure 2-23NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter229

  • Chapter3:AlloyTesting

    NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter31

    Chapter 3 ALLOY TESTING

    USING ALLOY TESTING MODE

    Alloy Testing Mode is not enabled on your NITON XLp analyzer. For more information on this feature please contact NITONs Customer Service Department in the United States, Toll free, at (800) 875-1578, or outside the United States at + 1-978-670-7460 or your authorized NITON Service Center.

  • Chapter4:PbPaintModeChapter 4 PB PAINT MODE

    USING PB PAINT MODE

    Your NITON XLp 300A/700A Series Lead-in-Paint Analyzer is designed to detect and quantify the amount of lead present in painted surfaces. Your analyzer also tracks important information about your site readings using the integrated bar-code scanner or the analyzers control panel.

    Both Paint Modes can be used interchangeably to measure lead concentrations in paint in mg/cm2. In all paint modes, NITON ana-lyzers simultaneously measure and analyze both K-shell and L-shell lead x-rays to determine:

    1. The numerical value of the lead in mg/cm2 present in the sam-ple;

    2. The 95% confidence interval; and 3. Whether the sample has a lead concentration that is greater-

    than-or-equal-to ("Positive") or less-than ("Negative") the lead Action-level (in mg/cm2) that has been entered.

    Note: In all paint testing modes, if a test is stopped before a "Positive" or "Negative" determination has been made, you will get a "Null" test result.NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter41

  • Chapter4:PbPaintModeTHE PB PAINT MODE MENU

    All NITON XLp 300A/700A Series Lead-in-Paint Analyzer Mode functions are accessible from the Pb Paint Mode Menu and sub-sidiary menus. Each of the instrument functions represented by an icon on the Pb Paint Mode Menu screen may be selected by choosing the appropriate icon. When one of these Pb Paint Mode Menu icons is selected, the function specific sub-menu appropriate to that icon will be displayed.

    The Standard Mode icon allows you to select the Lead-in-Paint Standard Mode. In Standard Mode, the instrument reads until a 95% confident reading of "Positive" or "Negative" versus the Action-level is achieved. Then the instrument displays either Posi-tive or Negative, and the Result in mg/cm2. In Standard Mode, testing times will vary somewhat from sample to sample. The instrument will measure only until a 95% confident reading of "Positive" or "Negative" (versus the Action-level you have set) has been attained. Press the down section on the 4-way touchpad to see the Depth Index.

    The Depth Index is a numerical value indicating the amount of non-leaded paint covering the lead (if any) detected by the analyzer.

    Figure 4-1NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter42

  • Chapter4:PbPaintModeA Depth Index of less than 1.5 indicates a reading very near the surface. A Depth Index between 1.6 and 4.0 indicates a moderate depth, while a Depth Index of greater than 4.0 indicates a deeply buried reading.

    The K+L Mode icon allows you to select the Lead-in-Paint K+L Mode. In K & L Mode, the instrument displays the complete test information continuously, from the beginning of each reading, including the K-shell reading with two-sigma confidence interval, the L-shell reading with two-sigma confidence interval, the combined reading (Pb) with two-sigma confidence interval, and the Depth Index. With each reading, a Null result is displayed until a Positive or Negative result is determined. In K & L Mode, you may continue readings indefinitely after a "Positive" or "Negative" result is obtained, until you have attained a desired measurement time or degree of precision.

    The Set Action Level icon allows you to change the Lead-in-Paint Action Level in your analyzer to match the current Action Level used in your locality. Selecting the Set Action Level icon brings up the Set Action Level Screen.NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter43

  • Chapter4:PbPaintModeTHE STANDARD MODE MENU

    All NITON XLp Standard Mode functions are accessible from the Standard Mode Menu and subsidiary sub-menus. When the Stan-dard Mode Menu Data Entry icon is selected, the function spe-cific sub-menu appropriate to that icon will be displayed.

    Select the Data Entry icon from the Standard Mode Menu input the reading parameters for the reading. You may input the reading parameters in one of three ways:

    Scan in the bar coded parameter value using the standard acces-sory barcode sheet found in the case of your NITON XLp ana-lyzer, or print your own with a bar code font. The parameter value you scan in will be used for that reading. After setting the parameters you want to set, you may continue with the reading.

    Type the parameter value using the Virtual Keyboard. The parameter value you type in will be used for that reading. After setting the parameters you want to set, you may continue with the reading.

    Select the parameter value using the drop down lists of pre-defined values. The parameter value you select will be used for that reading. After setting the parameters you want to set, you may continue with the reading.

    Figure 4-2aNITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter44

  • Chapter4:PbPaintModeThe current Lead-in-Paint Action Level is displayed near the bot-tom of the screen. If this Action level does not match the Action Level in your locality, Reset the Action Level from the Set Action Level icon on the Lead Paint Menu.

    The Batt Life: XX% line shows you the percentage of battery life left before recharging is needed.NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter45

  • Chapter4:PbPaintModeTHE K+L MODE MENU

    All NITON XLp K+L Mode functions are accessible from the K+L Mode Menu and subsidiary sub-menus. When the K+L Menu Data Entry icon is selected, the function specific sub-menu appropriate to that icon will be displayed.

    Select the Data Entry icon from the K+L Mode Menu input the reading parameters for the reading. You may input the reading parameters in one of three ways:

    Scan in the bar coded parameter value using the standard acces-sory barcode sheet found in the case of your NITON XLp ana-lyzer, or print your own with a bar code font. The parameter value you scan in will be used for that reading. After setting the parameters you want to set, you may continue with the reading.

    Type the parameter value using the Virtual Keyboard. The parameter value you type in will be used for that reading. After setting the parameters you want to set, you may continue with the reading.

    Select the parameter value using the drop down lists of pre-defined values. The parameter value you select will be used for

    Figure 4-2bNITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter46

  • Chapter4:PbPaintModethat reading. After setting the parameters you want to set, you may continue with the reading.

    The current Lead-in-Paint Action Level is displayed near the bot-tom of the screen. If this Action level does not match the Action Level in your locality, Reset the Action Level from the Set Action Level icon on the Lead Paint Menu.

    The Batt Life: XX% line shows you the percentage of battery life left before recharging is needed.NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter47

  • Chapter4:PbPaintModeTHE SET ACTION LEVEL SCREEN

    The Set Action Level Screen can be accessed by selecting the Set Action Level icon from the Paint Mode Menu. This screen allows you to set a new Action Level or change an existing Action Level.

    To set a new Action Level or change an existing Action Level, select the digits from the virtual numeric keypad displayed. This will append the selected digits onto the existing Action Level. For example, if the current Action Level is 2.5, selecting 4 from the vir-tual numeric keypad will display an Action Level of 2.54 on the screen. If the Action Level is cleared, selecting 2 and . and 5 from the virtual numeric keypad will display 2.5 as the new Action Level.

    The Clear Screen Button clears the entire Action Level. For exam-ple, selecting this screen button while an Action Level of 2.5 is dis-played will clear the Action Level to zero, displayed as . on the screen.

    The Clear Last Entry Screen Button clears the last digit you entered. For example, if the Action Level reads 2.54, selecting the

  • Chapter4:PbPaintModeSelecting the Enter Screen Button will place whatever number is displayed as the Action Level on the screen into the analyzers memory as the new Action Level. For example, if the Action Level displayed is 2.5, selecting the Enter Screen Button will place 2.5: into the analyzers memory as the new Action Level.

    The Action Level entered must be between 3.0 and 0.3 inclu-sive. Any other value will be held as invalid and rejected. See Fig-ure 4-2d.

    Figure 4-2dInvalid Action LevelNITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter49

  • Chapter4:PbPaintModeTAKING A READING

    There are five different methods of operation for taking a sample measurement, and your analyzer will be configured to use one of those methods for Lead-in-Paint samples, depending on the regula-tory requirements of your locality. These methods are:

    Trigger-Only method. With the Trigger-Only method, you only need to place the measurement window close to the surface to be analyzed and pull the trigger for sample analysis to be initi-ated.

    Trigger-and-Proximity-Sensor method. With the Trigger-and-Proximity-Sensor method, you must place the measurement window against the surface to be analyzed to engage the prox-imity sensor on the front of the instrument, then pull the trigger for sample analysis to be initiated.

    Momentary-Trigger-Touch-and-Proximity-Sensor method. With the Momentary-Trigger-Touch-and-Proximity-Sensor method, you must place the measurement window against the surface to be analyzed to engage the proximity sensor on the front of the instrument, then pull the trigger.

    The trigger may be released and the reading will continue until you release the proximity button, or other criteria (such as Max Time) are reached. This is the primary mode of operation for the XLi XLp 300A/700A Series Lead-in-Paint Analyzer in the USA.

    Trigger-and-Interlock method. With the Trigger-and-Interlock method, you need to place the measurement window close to the surface to be analyzed, press and keep pressing the interlock button at the rear of the instrument with your free hand, then pull the trigger for sample analysis to be initiated.

    Trigger-Interlock-and-Proximity-Sensor method. With the Trig-ger-Interlock-and-Proximity-Sensor method, you must place the measurement window against the surface to be analyzed to engage the proximity sensor on the front of the instrument, press and keep pressing the interlock button at the rear of the instrument with your free hand, then pull the trigger for sample analysis to be initiated.

    After your NITON XLp analyzer is calibrated and your Data Entry is complete, initiate a sample reading using the appropriate method. If you attempt to initiate a sample reading using a different method, the analyzer will inform you that one or more of the preconditions need to be met in order for sample analysis to begin. NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter410

  • Chapter4:PbPaintMode WARNING!

    The Proximity Button must remain depressed for the duration of the reading in Standard Mode or K+L Mode. If the Proxim-ity Button is released, the three LED lights will stop blinking, the shutter will close, and the measurement will end. The flash-ing of the LED lights is not synchronized to optimize power consumption.

    To end a K+L Mode test, simply release the Proximity Button.

    WARNING!

    The three LED warning lights are designed to blink only dur-ing instrument calibration (See Chapter 2 page 16) or during a measurement, where the shutter is open and the preconditions for operation are in effect. If the LED lights blink at any other time, disconnect the battery pack immediately, place the instru-ment in its shielded holster, place the holster in the shielded car-rying case, and call Thermo Electron Corporations Service Department in the United States, toll free, at (800) 875-1578, or outside the United States, at +1-978-670-7460, or your local Authorized NITON Service Center.

    Your NITON Analyzer will display the Results Screen throughout the duration of each reading, The Results Screen is updated regu-larly throughout the reading. When the reading is complete, a final screen update will appear, and your NITON analyzer will display the final results of the measurement which has just been completed.

    !

    !NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter411

  • Chapter4:PbPaintModeSTANDARD MODE RESULTS SCREEN

    Before the analyzer has reached a determination, the result will be shown as Null. Your analyzer will beep twice when a result is reached then terminate the reading. The display will change from Null to show the result, either Positive for lead detected above the action level, or Negative for no lead or lead below the action level. It will also display the amount of lead detected in mg/cm2.

    If you want to see the Depth Index, press the down section on the 4-way touchpad.

    The Depth Index is a numerical value indicating the amount of non-leaded paint covering the lead (if any) detected by the analyzer. A Depth Index of less than 1.5 indicates a reading very near the surface. A Depth Index between 1.6 and 4.0 indicates a moderate depth, while a Depth Index of greater than 4.0 indicates a deeply buried reading.

    Reading Number

    Nominal Secondsfor this Reading

    Analysis Mode

    Result

    Lead detected inmg/cm2

    Return Button Data Button Spectra Button

    Optionally DisplayedDepth Index

    Figure 4-3ANITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter412

  • Chapter4:PbPaintModeK+L MODE RESULTS SCREEN

    The K+L Mode Results Screen will show the basic display indi-cated in Figure 4-3B throughout the reading. Your analyzer will beep twice to indicate it has reached a conclusion, and the Result field will change from Null to Positive or Negative, but the reading will continue for as long as you continue to contact the Proximity Sensor.

    The K+L Results Screen shows the reading results and error for both K and L-shell readings. The Lead Detected in mg/cm2 total field is the result of the instrument softwares determination as to which reading, K or L-shell, best represents the true condition.

    The Depth Index is a numerical value indicating the amount of non-leaded paint covering the lead (if any) detected by the analyzer. A Depth Index of less than 1.5 indicates a reading very near the surface. A Depth Index between 1.6 and 4.0 indicates a moderate depth, while a Depth Index of greater than 4.0 indicates a deeply buried reading.

    Reading Number

    Nominal Secondsfor this Reading

    Analysis ModeResult

    Lead detected in

    mg/cm2 total

    Return Button Data Button Spectra Button

    L-shell

    Lead detected in

    Lead detected inK-shell

    Depth Index

    ReadingError

    Figure 4-3BNITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter413

  • Chapter4:PbPaintMode

    SMincoTHE DATA ENTRY SCREENS

    The Data Entry Screen and subsidiary sub-screens allow you to set the values for various parameters tracked by the system along with the actual analysis results. These parameters all describe the particular test target to be analyzed. The location of the target in the site, the type of target, the surface and substrate, the condition of the surface, and the inspector performing the test are some of the parameters tracked by the analyzer.

    Navigating the Data Entry Screen

    Above is a sample of the Data Entry Screen. To navigate through the Data Entry Screen and select your parameter settings, you can use the touch screen display or 4-way touch pad and control panel buttons.

    Screen Name

    Menu Code Number

    Return Clear All Button

    Next Screen Button

    Data Entry Screen SAMPLE

    KB Button

    Parameter Row

    Button

    Selecting theKB buttonsbrings up thevirtual keyboard

    Prev ScreenButton

    Figure 4-4

    electing theenu Code Numberitiates a barde scan

    Parameter Name

    brings up theselection lists

    Selecting theParameter NamesNITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter414

  • Chapter4:PbPaintMode The following description of screen navigation using the control panel assumes that the instrument is held so that the display is rotated to the left as in the figure above.

    To move from column to column, use the Right and Left portion of the 4-way touch pad.

    To move from row to row, use the Up and Down portions of the 4-way touch pad.

    To access the Return, Clear All, Prev, and Next but-tons, press the On/Off button on the control panel once. To return to the parameter settings, press the On/Off button again. This is a toggle between those two screen areas.

    To select the highlighted option, press the Enter button on the control panel.

    The Data Entry Screen is divided into sections of 3 setting parame-ters. By using the Down portion of the 4-way touch pad when you are on the last row of a section, the display will change to the next section. By using the Up portion of the 4-way touch pad when you are on the first row of a section, the display will change to the previ-ous section.

    By selecting the Return screen button, you will exit the Data Entry Screen. Selecting the Clear All screen button will clear all the settings.

    Touch Screen Display

    On/Off Button

    Down

    Right

    4-way touch- pad

    UpEnterButton

    LeftFigure 4-5NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter415

  • Chapter4:PbPaintModeUSING THE DATA ENTRY SCREEN

    This is the first section of the Data Entry Screen. There are five parameters in this section. The screen can display 13 characters in each parameter field, but internally the field can hold 32 characters maximum, all of which can be accessed and displayed on your computer using the NDT software.

    Selecting Component allows you to input the reading location component parameter.

    Selecting Substrate allows you to input the reading location sub-strate parameter.

    Selecting Side allows you to input the reading location side param-eter.

    Selecting Condition allows you to input reading the reading loca-tion condition parameter.

    Selecting Color allows you to input the reading location color parameter.

    Selecting the Menu Code Number will initiate a bar code scan to input pre-printed bar code parameter values

    Figure 4-6ANITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter416

  • Chapter4:PbPaintMode Selecting the Parameter Name will access the particular sub-menu for that parameter, allowing you to select the parameter value from a pre-determined list.

    Selecting the KB button allows you to input a parameter value as required using the Virtual Keyboard.

    This is the second section of the Data Entry Screen. There are three parameters in this section.

    Selecting Site allows you to input the reading location site parame-ter.

    Selecting Inspector allows you to input the reading inspector parameter.

    Selecting Floor allows you to input the reading floor parameter.

    Selecting Room allows you to input the reading location room parameter.

    Selecting Misc 1 allows you to input one pertinent miscellaneous reading parameter.

    Figure 4-6BNITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter417

  • Chapter4:PbPaintMode Selecting the Menu Code Number will initiate a bar code scan to input pre-printed bar code parameter values

    Selecting the Parameter Name will access the particular sub-menu for that parameter, allowing you to select the parameter value from a pre-determined list.

    Selecting the KB button allows you to input a parameter value as required using the Virtual Keyboard.

    This is the last section of the Data Entry Screen. There are two parameters in this section.

    Selecting Misc 2 allows you to input one other pertinent miscella-neous reading parameter.

    Selecting the Menu Code Number will initiate a bar code scan to input pre-printed bar code parameter values

    Selecting the Parameter Name will access the particular sub-menu for that parameter, allowing you to select the parameter value from a pre-determined list.

    Selecting the KB button allows you to input a parameter value as required using the Virtual Keyboard.

    Figure 4-6DNITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter418

  • Chapter4:PbPaintModeA SAMPLE PARAMETER VALUE SUB-SCREEN

    Following is a sample of the pre-determined lists of parameter val-ues which can be accessed by selecting the Parameter Name in the Data Entry Screen.

    Selecting the First Value will enter the value Concrete in the Sub-strate parameter.

    Selecting the Second Value will enter the value Drywall in the Substrate parameter.

    Selecting the Third Value will enter the value Metal in the Sub-strate parameter.

    Selecting the Fourth Value will enter the value Miniblind in the Substrate parameter.

    Selecting the Fifth Value will enter the value Plaster in the Sub-strate parameter.

    Name of the Parameter Number of values in list

    FirstValue

    ThirdValue

    Fifth Value

    Prev

    ButtonReturn Button Next Screen ButtonScreen

    Figure 4-7A

    Value

    Value

    Value

    Second

    Fourth

    Sixth

    Value ListN-R

    Value List

    Value List

    Value List

    S-Z

    G-M

    A-FNITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter419

  • Chapter4:PbPaintModeSelecting the Sixth and final Value will enter the value Wood in the Substrate parameter.

    Selecting the Prev Screen Button will return you to the previous screen in the sub-menu, if any.

    Selecting the Next Screen Button will advance you to the next screen in the sub-menu, if any.

    Selecting the Return Button will bring you back to the Data Entry Screen.

    Selecting the Value List A-F Button list value choices which begin with the letter A through the letter F.

    Selecting the Value List G-M Button list value choices which begin with the letter G through the letter M.

    Selecting the Value List N-R Button list value choices which begin with the letter N through the letter R.

    Selecting the Value List S-Z Button list value choices which begin with the letter S through the letter Z.NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter420

  • Chapter4:PbPaintModeCALIBRATING THE XLP 300A/700A SERIES ANALYZER FOR LEAD-IN-PAINT ANALYSIS

    Warm-upTurn the instrument on. Before entering the instrument password, let the instrument stabilize for 5 minutes. You may then enter your password and continue.

    Verify Date and TimeYour instrument must have the correct date and time in order to obtain accurate results. Verify the correct Date and Time from the Main Menu by selecting Utilities. From the Utilities Menu, select Specs. Tap the touch screen display or press any button on the Control Pad to return to the Main Menu.

    If the Date and Time are incorrect, follow the instructions found elsewhere in this User Guide to make the necessary adjustments.

    Instrument Internal CalibrationThe instrument will prompt the user to perform an internal calibra-tion prior to testing. The instrument may also perform an internal calibration at any time when initiated by the user. From the Main Menu, select Utilities. From the Utilities Menu, select Cali-brate. From the Calibrate Menu, select Calibrate Detector. When the calibration is completed, select RETN to access the Main Menu.

    Initial Calibration Procedure Using Lead Paint Standards

    Caution

    The initial calibration procedure using lead paint standards should be performed using a substrate known to be free of lead, such as the XLp Users Guide. Do not use the NITON case for a substrate.

    From the Main Menu, select Mode to access the Mode Menu. Select Pb Paint to access the Pb Paint Menu. Select K + L Mode.

    !NITONXLp300SeriesLeadinPaintAnalyzerUsersGuideChapter421

  • Chapter4:PbPaintModePerform a twenty source-second reading on the front side of the nominal 1.0 mg/cm2 Lead Paint S