4226 RfR BCL Chanderia ER Calculations 20110427

download 4226 RfR BCL Chanderia ER Calculations 20110427

of 6

Transcript of 4226 RfR BCL Chanderia ER Calculations 20110427

  • 7/29/2019 4226 RfR BCL Chanderia ER Calculations 20110427

    1/6

    Description Notation

    The electricity supplied from the project activity to the cement plant, EGCP,y

    The emissions factor of the baseline electricity supply source, If in the

    baseline scenario electricity is supplied from the grid, then EFElec, y is the

    emission factor of the grid - EFGrid,y; if electricity is supplied from the

    identified specific captive power generation source, then EFElec, y is the

    emission factor of it EFCaptive,y

    EFCaptive,y

    The fossil fuel (i.e. coal) consumption rate of the identified generation source

    (IGS) to supply EGYFIIGS

    The emission coefficient of the fuel (i.e. coal) used in identified generation

    source, expressed as tCO2/per GJ lower heating value.COEF

    IGS

    CO2 emission factor per unit of energy of the fuel used in identified

    generating source, expressed as tCO2 per unit mass or volume unit.

    (TCO2/ton of coal)

    EFCO2, fuel, IGS

    Net calorific value (energy content) per mass or volume unit of a fuel used in

    identified generating source; (TJ/ton of coal)NCVfuel,IGS

    Electricity supplied from project activity to the grid (MWh) EGGrid,y

    Emission factor of electricity grid EFGrid,y

    Baseline emission in the year y EBy

    The ex ante design estimate of the change in the energy consumption of each

    clinker kiln due to project implementationEIi

    carbon coefficient of the fuel used in the cement works in yeary to raise the

    necessary heat for clinker productionCOEFfuel,y

    CO2 emission factor per unit of energy of the fuel used in clinker production

    in the year y, expressed as tCO2 per unit mass or volume unit. (TCO2/unit

    mass or volume)

    EFCO2, fuel, y

    Net calorific value (energy content) per mass or volume unit of a fuel used in

    clinker production in the year; (TJ/unit mass or volume)NCVfuel,y

    Annual clinker production from the ith clinker production line Oclinker,i

    Project emission in the year y PEy

    Determination of Emissions Reduction in the year y ERy

    ipcc

    Computation of Emission Reduction for "Utilisation of the thermal energy co

    Determination of Project Emissions in the year y (EBy)

  • 7/29/2019 4226 RfR BCL Chanderia ER Calculations 20110427

    2/6

    Unit Value

    MWh 34810

    tCO2/MWh 1.150

    GJ/MWh 12.00

    tCO2/GJ 0.09581

    TCO2/ton NA

    TJ/ton of coal NA

    MWh 0.000

    tCO2 /MWh 0.8

    tCO2 40026

    TJ/ton Clinker 0

    tCO2/TJ of input

    fuelNA

    TCO2/unit mass or

    volumeNA

    TJ/unit mass or

    volumeNA

    ton of clinker 1996500

    tCO2 0

    tCO2 40026

    tent of the waste gas of clinker cooler a

  • 7/29/2019 4226 RfR BCL Chanderia ER Calculations 20110427

    3/6

    Remarks

    As per the detailed project report provided by the equiment suppliers and consultant

    Calculated based upon FIIGS and COEFIGS below mentioned

    Considering heat rate of the new coal based power plant - 2837kcal/kWh (as per the supplier)

    No supply of power (generated by the waste heat recovery based captive power plant) to grid

    Emission factor of NEWNE grid

    As per equipment supplier there will be no change in fuel consumption during clinker

    manufacturing due to the project activity

    As per the rated capacity of the kilns

    The same is not required as the ex-ante project emisison will be zero as EIi is assumed as

    zero following equipment supplier's recommendation in this regard (i.e. there will be no

    change in fuel consumption during clinker manufacturing due to the project activity)

    nd pre-heater for power generation at a cement plant in Rajasthan"

    The factor-COEFIGS has been calculated following the methodological guidance based on LabAnalysis Report (enclosed as Annexure-XIV) conducted on coal which would have been used

    in the baseline coal based power plant and the same is found to be 0.11665tCO2/GJ (Please

    refer to worksheet 'COEFigs' for details) . However the same was compared with the same

    factor reported in Indias Initial National Communication to the United Nations Framework

    Convention on Climate Change (NATCOM) which shows this factor as 0.0958tCO2/GJ.

    Therefore consideration of this factor from NATCOM Report will entail a conservative

    computation of baseline emissions and hence emission reductions. This justifies the

    consideration of this factor as per the NATCOM Report.

  • 7/29/2019 4226 RfR BCL Chanderia ER Calculations 20110427

    4/6

    95.81

  • 7/29/2019 4226 RfR BCL Chanderia ER Calculations 20110427

    5/6

    Description Notation Unit

    The emission coefficient of the fuel (i.e. coal) used in identified

    generation source, expressed as tCO2/per GJ lower heating value.COEFIGS tCO2/GJ

    CO2 emission factor per unit of energy of the fuel used in identified

    generating source, expressed as tCO2 per unit mass or volume unit.

    (TCO2/ton of coal)

    EFCO2, fuel, IGS TCO2/ton

    Net calorific value (energy content) per mass or volume unit of a fuel

    used in identified generating source; (TJ/ton of coal)NCVfuel,IGS TJ/ton of coal

    The emission coefficient of the fuel (i.e. coal) used in identified

    generation source, expressed as tCO2/per GJ lower heating value.COEFIGS tCO2/GJ

    COEFIGS as per Lab analysi

    COEFIGS as per Indias Initial National Communication to the United Nations

    Dtermination of COEFIGS (conservative

  • 7/29/2019 4226 RfR BCL Chanderia ER Calculations 20110427

    6/6

    Value Remarks

    0.11665Calculated based upon EFCO2, fuel, IGS and NCVfuel,IGS below

    mentioned

    1.8454

    Coal analysis report (Ultimate analysis) conducted independent

    testing laboratory - ' National Council for cement and building

    materials'

    0.0158

    GCV to NCV conversion:

    - Using the following IPCC formulae determine the NCV of those

    fortnightly samples

    - NCV = GCV - 0.212H - 0.0245M - 0.0008O

    - Where H - Percentage of Hydrogen, M - Percentage of Moisture

    and O - Percentage of Oxygen (as determined from the ultimate

    analysis report)

    - Please note that here GCV and NCV are in Mega Joule/kg,

    therefore it is required to do the necessary unit adjustments

    (1kcal/kg = (4.186/10^3) = 0.004186 MJ/kg)

    Assuming GCV = 18.4017MJ/kg, O =9.23%, H = 3.63%,

    M=7.45% (Source: Coal analysis report conducted independent

    - '

    0.09581

    Please refer to Indias Initial National Communication to the

    United Nations Framework Convention on Climate Change

    (NATCOM)

    s report

    Framework Convention on Climate Change (NATCOM)

    figure to be chosen)