27 Single Line Display

download 27 Single Line Display

of 37

Transcript of 27 Single Line Display

  • Single-line Display

    EPLAN Training 1

    Single-line Display

  • Single-line Display

    EPLAN Training 2

    1 Drawing Schematics in Single-line Representation...................................3 1.1 Create a page for single-line display.........................................................3 1.2 Place the symbol.......................................................................................4 1.3 Place the connection definition point.........................................................6

    2 Showing Bus Topologies .............................................................................9 2.1 PLC card overview..................................................................................10 2.2 Insert bus ports .......................................................................................12 2.3 Insert bus cables.....................................................................................14

    3 Single-Line Display Compliant with the GOST Standard ........................18

    4 Creating a Bundle Connection Point Symbol...........................................25

    5 Comparing Functions / Components between Single-Line and Multi-Line Displays...............................................................................................32

    6 Numbering Cables by the GOST Standard ...............................................33

    7 Converting Macros .....................................................................................34

    8 Using the Numbering Functions................................................................35

    This functionality is only available for certain module packages. Info

  • Single-line Display

    EPLAN Training 3

    1 Drawing Schematics in Single-line Representation

    For the single-line display of schematics, you can use pages with a special page type. The placed symbols are connected together via autoconnecting. Using a connection definition point, you can display the number of conductors in the cable.

    Precondition:

    You have opened a project.

    Page > New

    1.1 Create a page for single-line display 1. In the New page dialog, select Schematic single-line from the drop-down list

    in the Page type field.

    EPLAN creates a page of type Schematic single-line.

  • Single-line Display

    EPLAN Training 4

    1.2 Place the symbol 1. Select Insert > Symbol.

  • Single-line Display

    EPLAN Training 5

    2. Select the desired symbol from the Symbol selection dialog.

    If you have selected a page of type Schematic single-line, only predefined single-line symbols will be offered for selection.

    3. Click [OK].

    4. Place the symbol on the page in the graphical editor.

  • Single-line Display

    EPLAN Training 6

    1.3 Place the connection definition point 1. Select Insert > Connection definition point.

  • Single-line Display

    EPLAN Training 7

    2. Place the connection definition point on the autoconnection line between the desired symbols in the graphical editor.

    3. In the Properties dialog, in the Connection definition point tab, enter the desired data.

  • Single-line Display

    EPLAN Training 8

    4. Click [OK].

    This functionality is only available for certain module packages. Info

  • Single-line Display

    EPLAN Training 9

    2 Showing Bus Topologies In EPLAN, bus topologies can be shown using PLC boxes and bus ports, which you insert on schematic pages in single-line display. Depending on the bus topology, PLC boxes can be used for different components. From a physical point of view, PLC cards can be stacked and combined into a so-called "bus node". The individual bus nodes can then be located in different places and are connected together using corresponding bus cables. To create a bus topology with PLC cards, proceed as follows:

    Precondition:

    You have opened a page of type Schematic single-line in the graphical editor.

  • Single-line Display

    EPLAN Training 10

    2.1 PLC card overview 1. Select the menu item Insert > Box / connection point / mounting panel >

    PLC box.

  • Single-line Display

    EPLAN Training 11

    2. Draw the PLC box representing a PLC card as a rectangle.

    3. In the properties dialog, enter the device data for the PLC box.

    4. Click [OK].

  • Single-line Display

    EPLAN Training 12

    5. Repeat the previous steps for all the other PLC cards.

    2.2 Insert bus ports 1. Select the menu item Insert > Box / connection point / mounting panel >

    Bus port.

  • Single-line Display

    EPLAN Training 13

    2. Place the bus port within the PLC cards.

    3. In the properties dialog that appears, enter the device data for the bus port; for the function definition select "Bus input" or "Bus output".

  • Single-line Display

    EPLAN Training 14

    4. Click [OK].

    5. Connect the corresponding bus nodes together for each bus system by generating autoconnect lines between the bus ports on the PLC cards.

    2.3 Insert bus cables Bus cables for bus systems are generally implemented using connection definition points.

  • Single-line Display

    EPLAN Training 15

    1. Select the menu items Insert > Connection definition point.

  • Single-line Display

    EPLAN Training 16

    2. Place the connection definition points on the connection lines between the cards.

    3. For each connection definition point, enter the connection data in the properties dialog.

  • Single-line Display

    EPLAN Training 17

    4. Click [OK].

    This functionality is only available for certain module packages. Info

  • Single-line Display

    EPLAN Training 18

    3 Single-Line Display Compliant with the GOST Standard

    In the GOST standard, it is permitted to combine multiple connections together into one line. In the vicinity of the connection points, the individual connections must be shown in individual form (multi-line) again. Combined connections must be labeled on the points at which they leave the bundle and where they enter the bundle.

    Precondition:

    You have opened a page in the graphical editor.

    1. Place the desired symbols on the page in the graphical editor.

  • Single-line Display

    EPLAN Training 19

    2. Place several bundle connection point symbols (T-node, angle, etc.) at the desired component to combine them to a bundle connection point.

  • Single-line Display

    EPLAN Training 20

    3. Generate another bundle connection point for the component to be connected.

    The bundle connection points are connected together via autoconnecting.

  • Single-line Display

    EPLAN Training 21

    4. Select Insert > Connection definition point.

  • Single-line Display

    EPLAN Training 22

    5. Place the connection definition point on the autoconnection line between the symbols.

  • Single-line Display

    EPLAN Training 23

    6. Enter the desired data in the Properties dialog, in the Connection definition point tab.

  • Single-line Display

    EPLAN Training 24

    7. Click [OK].

    This functionality is only available for certain module packages. Info

  • Single-line Display

    EPLAN Training 25

    4 Creating a Bundle Connection Point Symbol Bundle connection point symbols are special symbols which make it possible to transition from the multi-line to the single-line display.

    A bundle connection point symbol is combined from multiple individual symbols. You can put together your own bundle connection point symbol. The individual parts are connected together with a special colored autoconnection line. The following symbols are available in all four angle variants:

    T-node

    Double junction for the combined connection point

    Two angles for the ends (right and left)

    T-node for the connection points between the ends.

    The thin ends of the bundle connection point symbols are the connection points to the components, while the wide ends are the connection points to the autoconnection line.

    Precondition:

    You have opened a page in the graphical editor.

    Insert > Symbol

  • Single-line Display

    EPLAN Training 26

    1. From the Symbol selection, select the symbol Angle bundle left.

  • Single-line Display

    EPLAN Training 27

    2. Place the angle at the desired component.

  • Single-line Display

    EPLAN Training 28

    3. From the Symbol selection, select the symbol Angle bundle right.

  • Single-line Display

    EPLAN Training 29

    4. Place the angle at the desired component.

  • Single-line Display

    EPLAN Training 30

    5. From the Symbol selection, select the symbol Double junction - bundle.

    6. Place the symbol at the middle component.

    The Edit bundle connection point data dialog is opened.

    7. In the Edit bundle connection point data dialog, enter the desired designation for the connection point into the Bundle connection point designation field and click [OK].

  • Single-line Display

    EPLAN Training 31

    The Bundle connection point designation is accepted and displayed in the graphical editor.

    Note: Bundle connections (autoconnecting and symbols) are graphically not influenced by entries for the connection graphics on potentials or on connections.

    This functionality is only available for certain module packages. Info

  • Single-line Display

    EPLAN Training 32

    5 Comparing Functions / Components between Single-Line and Multi-Line Displays

    If you make a change to a multi-line object or a single-line object belonging to one, you can synchronize the objects with one another. You can be sure in this way that the change has been transferred to the matching counterpart object.

    Precondition:

    You have changed an object in the overview or the graphical editor.

    1. Select the desired object.

    2. Select the menu item Utilities > Synchronization and, for a multi-line object select Multi-line --> single-line and overview, for a single-line object select Single-line --> multi-line and overview and for an object in the overview, select Overview--> multi-line and single-line.

    This functionality is only available for certain module packages. Info

  • Single-line Display

    EPLAN Training 33

    6 Numbering Cables by the GOST Standard According to the GOST standard, the numbers of the cables are shown in circles. This circle interrupts the connection (autoconnecting) in the vicinity of the connection point.

    Precondition:

    You have opened a page in the graphical editor.

    Insert > Symbol

    1. From the Symbol selection, select the symbol for the two-sided cable definition.

    2. Place the symbol on the autoconnecting line between the desired objects.

    3. In the properties dialog, enter the connection data for the cable.

    This functionality is only available for certain module packages. Info

  • Single-line Display

    EPLAN Training 34

    7 Converting Macros You can convert single-line symbols to multi-line symbols and vice versa on a page in the graphical editor. The representation type changes accordingly. The other properties remain unchanged.

    Precondition:

    You have placed a macro in the graphical editor.

    1. Select the desired macro in the graphical editor.

    2. Select the menu items Utilities > Exchange symbols single-line multi-line.

    The representation type in the Symbol / function data tab of the properties dialog switches from single-line to multi-line or vice versa.

    This functionality is only available for certain module packages. Info

  • Single-line Display

    EPLAN Training 35

    8 Using the Numbering Functions You can number devices in the graphical editor.

    Precondition:

    You have placed one or more objects in the graphical editor.

    1. Select the desired objects in the graphical editor.

  • Single-line Display

    EPLAN Training 36

    2. You select the menu item Project Data > Devices > Number.

    All selected devices are listed in the Number dialog.

    3. Select Default from the drop-down list in the Filter field.

    4. Activate the filter.

    5. Select the Preview of result check box and click [OK].

    In the Preview of result dialog, the devices are shown with the new numbering.

    6. Click [OK].

    The device numbering is adopted.

  • Single-line Display

    EPLAN Training 37