22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm...

22
PROPOSED RENOVATION FOR KING 65 ALLAMBI AVE BROADBEACH WATERS JOB NUMBER - 5082 NOTES: * IMAGES ARE DIAGRAMATIC ONLY * REFER TO ELEVATIONS FOR DETAILS

Transcript of 22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm...

Page 1: 22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm high and inaccordance with as 1926.1 proposed renovation for jr 090513 b roof deck

PROPOSED RENOVATION FOR

KING

65ALLAMBI AVE

BROADBEACH WATERS

JOB NUMBER - 5082

NOTES:* IMAGES ARE DIAGRAMATIC ONLY* REFER TO ELEVATIONS FOR DETAILS

Page 2: 22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm high and inaccordance with as 1926.1 proposed renovation for jr 090513 b roof deck

Phone (07) 55 203 022Fax (07) 55 203 033

PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219

ABN 73 097 995 616

BSA License No: 1129687Email: [email protected]

© Copyright reserved in part or whole. Writtendimensions take preference.

Contractor to verify dimensions.Notify designers of discrepancies.

Failure to do so shall voidthe designers responsibilities.

TH

IS D

ES

IGN

IS T

HE

EX

CLU

SIV

E P

RO

PE

RT

Y O

F S

TU

AR

T O

SM

AN

BU

ILD

ING

DE

SIG

NS

N.B

ALL

WR

ITT

EN

DIM

EN

SIO

NS

TA

KE

PR

EC

ED

EN

CE

OV

ER

SC

ALE

D S

IZE

SB

E W

AR

NE

D: S

UB

ST

ITU

TIO

N O

F A

NY

ST

RU

CT

UR

AL

ME

MB

ER

S, A

ND

OR

AN

Y V

AR

IAT

ION

TO

AN

Y P

AR

T O

F T

HE

DE

SIG

N W

ILL

VO

ID A

NY

RE

SP

ON

SIB

ILIT

IES

OF

ST

UA

RT

OS

MA

N B

UIL

DIN

G D

ES

IGN

S F

OR

TH

E S

TR

UC

TU

RA

L IN

TE

GR

ITY

AN

D P

ER

FO

RM

AN

CE

OF

TH

E B

UIL

DIN

G

CLIENT

PROJECT

JOB NUMBER

BUILDER

DRAWN BY CHECKED BY

DESIGN

DATE

SCALES AMENDMENTS

SHEET NUMBERof

MEMBER OF

CHARTEREDMEMBER OF

MEMBER OF

queensland inc.association of

building designers

KING

PROPOSED RENOVATION65

ALLAMBI AVEBROADBEACH WATERS

5082

JR

A 09/05/2013

D180613E230713F020813G130813H150813I 020913

SO

CUSTOM

1:100 @ A3

2 22

J030913K190913L240913M181013N081113

DESCRIPTIONREV. DATE

PRELIMINARY PLANS ISSUEDA

DENOTES LOCATION OF SMOKE DETECTORS (refer electrical layout plans), TOBE HARD WIRED WITH EMERGENCY BACK-UP AND COMPLY WITH AS 3786.

WIND SPEED AS NOMINATED ON BRACING PLAN.

PROVIDE LIFT OFF HINGES TO W.C OR OPEN OUT DOOR OR MIN 1200mm CLEARANCEFROM DOOR TO PAN.

EXHAUST FANS FROM SANITARY COMPARTMENTS TO BE DUCTED TO THE OUTSIDEARE AIR OR TO A VENTED ROOF SPACE AND AS PER AS 1668.2

THESE NOTES ARE NEITHER EXHAUSTIVE NOR A SUBSTITUTE FOR REGUALTIONS,STATUTORY REQUIREMENTS, BUILDING PRACTICE OR CONTRACUAL OBLIGATIONS.

ALL CONSTRUCTION MATERIALS SUPPLIED MUST TAKE INTO ACCOUNT PROXIMITY TOCOASTAL OR INDUSTRIAL ENVIRONMENTS, IN ACCORDANCE WITH MANUFACTURERSSPECIFICATIONS

THESE PLANS ARE PROTECTED BY COPY RIGHT AND ARE THE PROPERTY OF THEAUTHOR.

KING65

ALLAMBI AVEBROADBEACH WATERS

JOB NUMBER - 5082

GENERAL NOTES

DO NOT SCALE PLANS, USE WRITTEN DIMENSIONS ONLY.

THE OWNER/BUILDER SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS, LEVELS,SETBACKS AND SPECIFICATIONS PRIOR TO COMMENCING WORKS OR ORDERINGMATERIALS AND SHALL BE RESPONSIBLE FOR ENSURING THAT ALL BUILDING WORKSCONFORM TO THE BUILDING CODE OF AUSTRALIA 2006, CURRENT AUSTRALIANSTANDARDS, BUILDING REGULATIONS AND TOWN PLANNING REQUIREMENTS,REPORT ANY DISCREPANCIES TO THIS OFFICE.

ALL WORKS SHALL COMPLY WITH BUT NOT LIMITED TO THE BUILDING CODE OFAUSTRALIAN AND THE AUSTRALIAN STANDARDS LISTED IN NOTE 4.

AS 1288 - 2006 GLASS IN BUILDINGS - SELECTION AND INSTALLATIONAS 1562 - 1992 DESIGN AND INSTALLATION OF SHEET ROOF AND WALL CLADDINGAS 1684 - 2010 NATIONAL TIMBER FRAMING CODEAS 2049 - 2002 ROOF TILESAS 2050 - 2002 INSTALLATION OF ROOF TILESAS 2870 - 1996 RESIDENTIAL SLAB AND FOOTINGS - CONSTRUCTIONAS/NZS 2904 - 1995 DAMP-PROOF COURSES AND FLASHINGSAS 3600 - 2000 CONCRETE STRUCTURESAS 3660 - 2000 BARRIERS FOR SUBTERRANEAN TERMITESAS 3700 - 2001 MASONRY IN BUILDINGSAS 3740 - 2004 WATERPROOFING OF WET AREAS IN RESIDENTIAL BUILDINGSAS 3786 - 1993 SMOKE ALARMSAS 4055 - 2006 WIND LOADINGS FOR HOUSINGAS 4100 - 1998 STEEL STRUCTURES

THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANY STRUCTURAL AND CIVILENGINEERING COMPUTIONS AND DRAWINGS.

SOIL CLASSIFICATION - REFER TO STRUCTURAL ENGINEERS SOIL TEST.

ALL BUILDINGS SHALL BE PROTECTED AGAINST TERMITE ATTACK IN ACCORDANCEWITH AS 3660.1 AND A DURABLE NOTICE SHALL BE PLACED IN THE METER BOXINDICATING TYPE OF BARRIER AND REQUIRED PERIODICAL INSPECTIONS.

SAFETY GLAZING TO BE USED IN THE FOLLOWINGS CASES -i) ALL ROOMS - WITHIN 500mm VERTICAL OF THE FLOORii) BATHROOMS - WITHIN 1500mm VERTICAL OF THE BATH BASEiii) FULLY GLAZED DOORSiv) SHOWER SCREENSv) WITHIN 300mm OF A DOOR AND <1200mm ABOVE FLOOR LEVELvi) WINDOW SIZES ARE NOMINAL ONLY, ACTUAL SIZES WILL VARYWITH MANUFACTURER, FLASHING ALL ROUND.

ALL GUTTERS TO BE STRAMIT QUEENSLANDER QUAD GUTTERING WITH MIN. 100x75RECTANGULAR OR 100 dia. DOWNPIPES, EACH DOWNPIPE SHALL SERVICE A MAXIMUMROOF AREA OF 36 sq.m OR SHALL BE POSITIONED AS PER AS 3500.3, 2003, SECTION 3.

STORMWATER TO BE TAKEN TO THE LEGAL POINT OF DISCHARGE AS DETERMINED BYTHE RELEVANT AUTHORITY.

TILED DECKS OVER LIVABLE AREAS ARE TO BE, IN THE FOLLOWING ORDER OVERTHEFLOOR JOISTS : 19mm COMPRESSED FIBRE CEMENT SHEET, WITH ONE LAYER OFPARCHEM EMERPROOF 750 WITH A SECOND LAYER OF SAND SEED WITH A DFT OF1300 MICRON, INSTALLED TO MANUF. SPECIFICATIONS, AND FLOOR TILES OVER, ALLCORNERS TO HAVE 20mm MASTIC SEALANT UNDER THE PARCHEM EMERPROOF 750.

FOOTINGS NOT TO ENCROACH TITLE BOUNDARIES OR EASEMENTS. IT ISRECOMMENDED THAT WHERE BUILDINGS ARE TO BE LOCATED IN CLOSE PROXIMITYOF BUNDARIES, A CHECK SURVEY BE CONDUCTED BY A LICENSED SURVEYOR.

ALL STEELWORK IN MASONRY TO BE HOT DIP GALVANISED.

ALL WET AREAS TO COMPLY WITH BCA 3.8.1.2 AND AS 3740. SPLASH BACKS SHALL BEIMPERVIOUS FOR 150mm ABOVE SINKS, TROUGHS AND HAND BASINS WITHIN 75mm OFTHE WALL.

PROVIDE WALL TIES AT 600mm SPACINGS BOTH VERTICAL AND HORIZONTAL ANDWITHIN 300mm OF ARTICULATION JOINTS. BRICK TIES TO BE STAINLESS STEEL.

SUB-FLOOR VENTILATION MINIMUM 7500mm sq FOR EXTERNAL WALLS AND 1500mm sqFOR INTERNAL WALLS BELOW BEARER.

THERMAL INSULATION; R2.5 BATTS TO CEILING AND R1.5 BATTS AND REFLECTIVE FOILTO EXTERNAL WALLS OR AS PER ENERGY RATING.

STAIR REQUIREMENTS : MIN. TREAD 240mm, MIN. RISER 115mm, MAX. RISER 190mm,SPACE BETWEEN OPEN TREADS MAX. 125mm. TREADS TO BE NON SLIP SURFACE.BALUSTRADES : MIN. 1000mm ABOVE LANDINGS WITH MAX. OPENING OF 125mm AND INACCORDANCE WITH BCA 3.9.2FOR STAINLESS STEEL BALUSTRADE, REFER TO Table 3.9.2.1 (WIRE BALUSTRADECONSTRUCTION - REQUIRED WIRE TENSION AMD MAXIMUM PERMISSIBLEDEFLECTION) OF THE BCA..

THE BUILDER SHALL TAKE ALL STEPS NECESSARY TO ENSURE THE STABILITY OFEXISTING AND NEW STRUCTURES THROUGH-OUT CONSTRUCTION.

LEGEND

CJ CONSTRUCTION JOINTDP DOWNPIPEFP FIRE PLACEFW FLOOR WASTEHWS HOT WATER SYSTEMAC AIR CONDITIONINGPS PLUMBING STACK / DUCTSP STEEL POSTT.B.C TO BE CONFIRMEDRL RELATIVE LEVELAHD AUSTRALIAN HEIGHT DATUMCSD CAVITY SLIDING DOOROHC OVER HEAD CUPBOARDFG FIXED GLASSFSR FLOOR SPACE RATIOLB LOAD BEARINGNGL NATURAL GROUND LINEUBO UNDER BENCH OVENWO WALL OVENDW DISHWASHERMW MICROWAVEWM WASHING MACHINEWIR WALK-IN-ROBESD SLIDING GLASS DOORASW ALUMINIUM SLIDING WINDOWADH ALUM. DOUBLE HUNG WINDOWAAW ALUM. AWNING WINDOWALW ALUM. LOUVRE WINDOWBCA BUILDING CODE OF AUSTRALIAAS AUSTRALIAN STANDARDS

SITE NOTES

ALL STORMWATER AND DRAINAGE TO BE IN COMPLIANCE WITH BCAPARTS 3.1.2 & 3.5.2 AS WELL AS AS/NZS 3500.

ENSURE 90mm DIAMETER AGRICULTURAL DRAINS ARE PROVIDED TOTHE BASE OF ALL CUTS AND RETAINING WALLS AND ARE CONNECTEDTO THE STORMWATER SYSTEM VIA SILT PIT/S TO THE RBSREQUIREMENTS.

THE EXTERNAL FINISHED SURFACE SURROUNDING THE BUILDINGMUST BE DRAINED TO MOVE SURFACE WATER AWAY FROM THEBUILDING AND GRADE TO PROVIDE A SLOPE NOT LESS THAN 50mmOVER THE FIRST 1000mm FROM THE BUILDING.

A MINIMUM HEIGHT OF 150mm SHALL BE MAINTAINED BETWEEN THETOP OF THE OVERFLOW GULLY RISER & THE LOWEST FIXTURECONNECTED TO THE DRAIN. THE OVERFLOW GULLY RISER SHALL BELOCATED AT 75mm ABOVE SURROUNDING GROUND LEVEL OR SHALLBE FINISHED AT A HEIGHT TO PREVENT THE INGRESS OF WATERWHEN LOCATED IN A PATH OR PAVED AREA.

CONNECT DOWNPIPES TO LEGAL POINT OF DISCHARGE VIA 100mmDIAMETER UPVC STORMWATER PIPE LAID WITH A MINIMUM FALL OF1:100, DISCHARGE TO THE SATISFACTION OF THE RELEVANTAUTHORITY.

ALL STORMWATER DRAINAGE BELOW GROUND SHALL BE SEWERGRADE WITH NO JOINTS UNDER SLAB INSTALLED TO AS3500.3, 2003.MINIMUM PIPE SIZE 100mmMINIMUM GRADE 1:100

ALL POOL FENCING SHALL BE MIN. 1200mm HIGH AND INACCORDANCEWITH AS 1926.1

PROPOSED RENOVATION FOR

090513JR

ROOF DECK OPTIONB 090513JR

CLIENT AMENDSC 300513JR

CLIENT AMENDS. GYM ADDEDD 180613JR

LAYOUT RECONFIGUREDE 230713JR

MINOR AMENDS. KITCHENF 020813JR

MAJOR CLIENT AMENDSG 130813JR

MINOR AMENDSH 150813JR

MINOR AMENDS. KITCHEN LAYOUTI 020913JR

MINOR AMENDS.J 030913JR

CLIENT AMENDS.K 190913JR

MINOR AMENDS. ENSUITES. GATEHOUSE ADDEDL 240913JR

WORKING DRAWINGS ISSUEDM 181013JR

AMENDS TO FLOOR STRUCTURE IN GYM, JOIST TO SUS. SLABN 081113ST

Page 3: 22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm high and inaccordance with as 1926.1 proposed renovation for jr 090513 b roof deck

Phone (07) 55 203 022Fax (07) 55 203 033

PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219

ABN 73 097 995 616

BSA License No: 1129687Email: [email protected]

© Copyright reserved in part or whole. Writtendimensions take preference.

Contractor to verify dimensions.Notify designers of discrepancies.

Failure to do so shall voidthe designers responsibilities.

TH

IS D

ES

IGN

IS T

HE

EX

CLU

SIV

E P

RO

PE

RT

Y O

F S

TU

AR

T O

SM

AN

BU

ILD

ING

DE

SIG

NS

N.B

ALL

WR

ITT

EN

DIM

EN

SIO

NS

TA

KE

PR

EC

ED

EN

CE

OV

ER

SC

ALE

D S

IZE

SB

E W

AR

NE

D: S

UB

ST

ITU

TIO

N O

F A

NY

ST

RU

CT

UR

AL

ME

MB

ER

S, A

ND

OR

AN

Y V

AR

IAT

ION

TO

AN

Y P

AR

T O

F T

HE

DE

SIG

N W

ILL

VO

ID A

NY

RE

SP

ON

SIB

ILIT

IES

OF

ST

UA

RT

OS

MA

N B

UIL

DIN

G D

ES

IGN

S F

OR

TH

E S

TR

UC

TU

RA

L IN

TE

GR

ITY

AN

D P

ER

FO

RM

AN

CE

OF

TH

E B

UIL

DIN

G

CLIENT

PROJECT

JOB NUMBER

BUILDER

DRAWN BY CHECKED BY

DESIGN

DATE

SCALES AMENDMENTS

SHEET NUMBERof

MEMBER OF

CHARTEREDMEMBER OF

MEMBER OF

queensland inc.association of

building designers

KING

PROPOSED RENOVATION65

ALLAMBI AVEBROADBEACH WATERS

5082

JR

A 09/05/2013

D180613E230713F020813G130813H150813I 020913

SO

CUSTOM

1:100 @ A3

3 22

J030913K190913L240913M181013N081113

REPORT STATUS DATE

WORKPLACE HEALTH & SAFETY REPORTCOMPLETED - DISCUSSED WITH & PROVIDED TOCLIENT ALONG WITH WORKING DRAWINGS 16/10/13

KING65

ALLAMBI AVEBROADBEACH WATERS

JOB NUMBER - 5082

b) SLIPPERY OR UNEVEN SURFACESFLOOR FINISHESSpecified finishes have been selected to minimise the risk of floors and

paved areas becoming slippery when wet or when walked on with wetshoes/feet. Any changes to the specified finish should be made in

consultation with the designer or, if this is not practical, surfaces with anequivalent or better slip resistance should be chosen.

The owner is responsible for the selection of surface finishes in the

pedestrian trafficable areas of this building. Surfaces should be selected in

accordance with AS HB 197:1999 and AS/NZ 4586:2004.

STEPS, LOOSE OBJECTS AND UNEVEN SURFACESDue to design restrictions for this building, steps and/or ramps are included

in the building which may be a hazard to workers carrying objects orotherwise occupied. Steps should be clearly marked with both visual and

tactile warning during construction, maintenance, demolition and at all timeswhen the building operates as a workplace.

Building owners and occupiers should monitor the pedestrian access ways

and in particular access to areas where maintenance is routinely carried outto ensure that surfaces have not moved or cracked so that they become

uneven and present a trip hazard. Spills, loose material, stray objects orany other matter that may cause a slip or trip hazard should be cleaned or

removed from access ways.Contractors should be required to maintain a tidy work site during

construction, maintenance or demolition to reduce the risk of trips and fallsin the workplace. Materials for construction or maintenance should be

stored in designated areas away from access ways and work areas.

2. FALLING OBJECTSLOOSE MATERIALS OR SMALL OBJECTSConstruction, maintenance or demolition work on or around this building is

likely to involve persons working above ground level or above floor levels.Where this occurs one or more of the following measures should be taken

to avoid objects falling from the area where the work is being carried out

onto persons below.1. Prevent or restrict access to areas below where the work

is being carried out.2. Provide toeboards to scaffolding or work platforms.

3. Provide protective structure below the work area.4. Ensure that all persons below the work area have

Personal Protective Equipment.

BUILDING COMPONENTSDuring construction, renovation or demolition of this building, parts of the

structure including fabricated steelwork, heavy panels and many other

components will remain standing prior to or after supporting parts are inplace. Contractors should ensure that temporary bracing or other required

support is in place at all times when collapse which may injure persons inthe area is a possibility.

Mechanical lifting of materials and components during construction,

maintenance or demolition presents a risk of falling objects. Contractorsshould ensure that appropriate lifting devices are used, that loads are

properly secured and that access to areas below the load is prevented or

restricted.

3. TRAFFIC MANAGEMENTParking of vehicles or loading/unloading of vehicles on this roadway maycause a traffic hazard. During construction, maintenance or demolition of

this building designated parking for workers and loading areas should beprovided. Trained traffic management personnel should be responsible for

the supervision of these areas.

Construction of this building will require loading and unloading of materials

on the roadway. Deliveries should be well planned to avoid congestion ofloading areas and trained traffic management personnel should be used to

supervise loading/unloading areas.

Busy construction and demolition sites present a risk of collision wheredeliveries and other traffic are moving within the site. A traffic management

plan supervised by trained traffic management personnel should be

adopted for the work site.

4. SERVICESRupture of services during excavation or other activity creates a variety of

risks including release of hazardous material. Existing services are located

on or around this site. Where known, these are identified on the plans but

the exact location and extent of services may vary from that indicated.Services should be located using an appropriate service (such as Dial

Before You Dig), appropriate excavation practice should be used and,where necessary, specialist contractors should be used.

(in locations with underground power)Underground power lines are located in or around this site. All underground

power lines must be disconnected or carefully located and adequate

warning signs used prior to any construction, maintenance or demolitioncommencing.

(in locations with overhead power lines )Overhead power lines are near or on this site. These pose a risk of

electrocution if struck or approached by lifting devices or other plant andpersons working above ground level. Where there is a danger of this

occurring, power lines should be, where practical, disconnected orrelocated. Where this is not practical adequate warning in the form of bright

coloured tape or signage should be used or a protective barrier provided.

5. MANUAL TASKSComponents within this design with a mass in excess of 25kg should belifted by two or more workers or by mechanical lifting device. Where this is

not practical, suppliers or fabricators should be required to limit thecomponent mass.

All material packaging, building and maintenance components should

clearly show the total mass of packages and where practical all itemsshould be stored on site in a way which minimises bending before lifting.

Advice should be provided on safe lifting methods in all areas where liftingmay occur.

Construction, maintenance and demolition of this building will require theuse of portable tools and equipment. These should be fully maintained in

accordance with manufacturer’s specifications and not used where faulty or(in the case of electrical equipment) not carrying a current electrical safety

tag. All safety guards or devices should be regularly checked and Personal

Protective Equipment should be used in accordance with manufacturer’sspecification.

6. HAZARDOUS SUBSTANCESASBESTOS(for alterations to a building constructed prior to 1990)

This building was constructed prior to 1990 and therefore may contain

asbestos either in cladding material or in fire retardant insulation material.The builder should check and, if necessary, take appropriate action before

demolishing, cutting, sanding, drilling or otherwise disturbing the existingstructure.

(for alterations to a building constructed prior to 1986)This building was constructed prior to 1986 and therefore is likely to contain

asbestos either in cladding material or in fire retardant insulation material.The builder should check and, if necessary, take appropriate action before

demolishing, cutting, sanding, drilling or otherwise disturbing the existingstructure.

POWDERED MATERIALSMany materials used in the construction of this building can cause harm if

inhaled in powdered form. Persons working on or in the building duringconstruction, operational maintenance or demolition should ensure good

ventilation and wear Personal Protective Equipment including protectionagainst inhalation while using powdered material or when sanding, drilling,

cutting or otherwise disturbing or creating powdered material.

TREATED TIMBER

The design of this building includes provision for the inclusion of treatedtimber within the structure. Dust or fumes from this material can be harmful.

Persons working on or in the building during construction, operationalmaintenance or demolition should ensure good ventilation and wear

Personal Protective Equipment including protection against inhalation ofharmful material when sanding, drilling, cutting or using treated timber in

any way that may cause harmful material to be released. Do not burntreated timber.

VOLATILE ORGANIC COMPOUNDSMany types of glue, solvents, spray packs, paints, varnishes and some

cleaning materials and disinfectants have dangerous emissions. Areaswhere these are used should be kept well ventilated while the material is

being used and for a period after installation. Personal ProtectiveEquipment may also be required. The manufacturer’s recommendations for

use must be carefully considered at all times.

SYNTHETIC MINERAL FIBRE

Fibreglass, rockwool, ceramic and other material used for thermal or sound

insulation may contain synthetic mineral fibre which may be harmful ifinhaled or if it comes in contact with the skin, eyes or other sensitive parts

or the body. Personal Protective Equipment including protection againstinhalation of harmful material should be used when installing, removing or

working near bulk insulation material.

TIMBER FLOORS

This building contains timber floors which have an applied finish. Areaswhere finishes are applied should be kept well ventilated during sanding

and application and for a period after installation. Personal ProtectiveEquipment may also be required. The manufacturer’s recommendations for

use must be carefully considered at all times.

7. CONFINED SPACESEXCAVATIONConstruction of this building and some maintenance on the building will

require excavation and installation of items within excavations. Wherepractical, installation should be carried out using methods which do not

require workers to enter the excavation. Where this is not practical,adequate support for the excavated area should be provided to prevent

collapse. Warning signs and barriers to prevent accidental or unauthorised

access to all excavations should be provided.

ENCLOSED SPACESEnclosed spaces within this building may present a risk to persons entering

for construction, maintenance or any other purpose. The designdocumentation calls for warning signs and barriers to unauthorised access.

These should be maintained throughout the life of the building. Where

workers are required to enter enclosed spaces, air testing equipment andPersonal Protective Equipment should be provided.

SMALL SPACES

Some small spaces within this building will require access by constructionor maintenance workers. The design documentation calls for warning signs

and barriers to unauthorised access. These should be maintainedthroughout the life of the building. Where workers are required to enter

small spaces they should be scheduled so that access is for short periods.

Manual lifting and other manual activity should be restricted in smallspaces.

8. PUBLIC ACCESSPublic access to construction and demolition sites and to areas under

maintenance causes risk to workers and public. Warning signs and securebarriers to unauthorised access should be provided. Where electrical

installations, excavations, plant or loose materials are present they shouldbe secured when not fully supervised.

9. OPERATIONAL USE OF BUILDINGThis building has been designed to requirements of the specific building

classification identified within the drawings. Where a change of use occursat a later date a further assessment of the workplace health and safety

issues should be undertaken, in accordance with the provisions of the WorkHealth and Safety Act 2011 or subsequent replacement Act.

(Where the specific use of the building is not known at the time of the

completion of this report and a further assessment of the workplace health

and safety issues should be undertaken at the time of fit-out for the end-user.)

10. OTHER HIGH RISK ACTIVITYAll electrical work should be carried out in accordance with Code ofPractice: Managing Electrical Risks at the Workplace, AS/NZ 3012 and all

licensing requirements.

All work using Plant should be carried out in accordance with Code ofPractice: Managing Risks of Plant at the Workplace.

All work should be carried out in accordance with Code of Practice:Managing Noise and Preventing Hearing Loss at Work.

Due to the history of serious incidents it is recommended that particularcare be exercised when undertaking work involving steel construction and

concrete placement. All the above applies.

WORKPLACE HEALTH &SAFETY REPORT

Compiled in accordace with Work Health andSafety Act 2011.

IDENTIFIED HAZARD AREAS

1. FALLS, SLIPS, TRIPSa) WORKING AT HEIGHTSDURING CONSTRUCTION

Wherever possible, components for this building should be prefabricatedoff-site or at ground level to minimise the risk of workers falling more than

two metres. However, construction of this building will require workers to beworking at heights where a fall in excess of two metres is possible and

injury is likely to result from such a fall. The builder should provide asuitable barrier wherever a person is required to work in a situation where

falling more than two metres is a possibility.

DURING OPERATION OR MAINTENANCE

Cleaning and maintenance of windows, walls, roof or other components ofthis building will require persons to be situated where a fall from a height in

excess of two metres is possible. Where this type of activity is required,scaffolding, ladders or trestles should be used in accordance with relevant

codes of practice, regulations or legislation.

Cleaning and maintenance of windows, walls, roof or other components of

this building will require persons to be situated where a fall from a height inexcess of two metres is possible. Where this type of activity is required,

scaffolding, fall barriers or Personal Protective Equipment should be used inaccordance with relevant codes of practice, regulations or legislation.

Anchorage points for portable scaffold or fall arrest devices have been

included in the design for use by maintenance workers. Any personsengaged to work on the building after completion of construction work

should be informed about the anchorage points.

PROPOSED RENOVATION FOR

Page 4: 22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm high and inaccordance with as 1926.1 proposed renovation for jr 090513 b roof deck

21-1

2adh

21-1

2adh

06-24asw 12-21asw

820

24-48 panelift door 24-48 panelift door

820

04-2

7afg

21-0

6alw

21-0

6alw

04-15asw04-15asw

21-09afg 21-06afg

21-1

2adh

21-1

2adh

820

720

720

720

820

720

820

820

24-15SD

720

620 620

820

12-21asw

720

720

1 2 3 4 5 6 7 8

12345 1 2 3 4 5

D.P

D.PD.P

D.P

494 11,908

NEW DRIVEWAY RE-GRADED TO SUIT NEW GARAGE LEVELPROPOSED EXTENSION SHOWN HATCHED.SITE AREA 1454 SQMNEW SITE COVER - 32.8%

NEW GATEHOUSE

DEMOLISHEXISTING WALLS

NEW SLIDING ENTRY GATE

DEMOLISH EXISTING PATH

FILL IN EXISTING GATE

3.47

2.96

3.11 3.07

3.06 3.09 3.08 3.04

3.03

2.98 2.97

3.00 2.92 2.92

2.90

2.93 2.80

2.9

9

2.96

2.97

3.04

3.07

3.06

3.06

3.15 3

.43

3.43 3

.43

3.43

3.44

3.44

3.43

3.40

3.41

3.41

3.4

1

3.46

3.47 3.50

3.74

3.95

3.40 3

.55

3.4

1 3.45

3.32 3.38

3.42

3.06

3.04

2.99

3.02

3.03

3.05

3.40 3.39

3.32

3.40

3.40 3.61 3.44

3.41

3.37 3.32

3.43

3.36

3.35

3.35 3.49

3.34

3.31

3.35

3.46

3.45

3.48

3.47

3.35

3.33

3.34

3.36

3.36

3.39

3.34

3.41

3.34 3.34 3.38 3.39

3.40

3.37

3.33

3.27 3.26

3.29

3.25

3.22

3.2

3

3.25

3.27

3.29

3.29

3.29 3.31 3.34

3.38

3.43

3.41

3.41

3.48

3.43

3.39

3.57 3.75

2.27

3.40

3.55

3.40

3.34

3.34

2.5

7

2.57

3.4

0 3.38

3.38

1.58

1.55

2.27

2.18 2.42

2.38

2.54

2.46 2

.40

2.65

2.44

1.27 2.43 2.49

2.50 2.50

2.44

2.50 2.50

2.52

2.51 2.51

2.50

2.53

2.53

2.51

2.5

1

2.52

2.29 2.29

2.23 2.27

2.30

2.20

2.30

2.29

2.26

2.26

2.46

1.73

1.69

1.23

1.24

0.66

0.66

0.65

0.64

0.63

0.65 0.65

1.53

0.17 0.08

1.52

1.38

2.30

2.52 2.24

2.50

2.39

2.35

2.55

2.44

2.49

2.72

2.5

8

2.58

2.78

2.54 2.47

2.52

2.76 3.78

3.78

3.79 3.79 3.96

3.95 3.95

FL

=3

. 97

2.58

2.54

2.54

2.56 2.56

3.21

3.21

2. 5

3 2.64

2.53

2.50 2.86

3.22

3.24 3.29

3.69

3.22

3.18

3.24

3.21

1.63

3.36

3.67

AL

LA

MB

IE A

VE

NU

E

337

RP88345

340

RP88345

1RP219316

Pool

Timber Jetty

Boat Ramp

Floating

Pontoon

ConcreteS

lab

Paved

Drivew

ay

Paved

Drivew

ay

Lip

of K

erb

Back o

f Kerb

Hydrant

TelstraPit

TelstraPit

Water

Meter

Water

Meter

TilesConc

Pavers

Drain

Pavers

Pavers

Pavers

Drain

St e

ps

Vera

ndah

Drain

Drain

Concrete Area

(Boat Storage)

Block Ret Wall

Block Fence Block Fence

Block Fence

Garage

1 & 2 STOREY

RENDERED DWELLING

TILE ROOF

(No.67)

Temporary

Shed

Stairs

StairsO

utdoor

Show

er

Rock

Feature

Garden

Bed

Garden

Stairs

Gla

ss L

ine

Garden

Bed

Gat e

Gat e

Gat e

Tiled

Area

Fence

Paved Area

(Pergola Over)

Stairs

Patio

St a

irs

Stairs

Gard

en

Gard

en

Grass

Grass

Palm

s

EP

Not

Area

Surveyed

1454m

(Vide R

P219316)

Path

130°0

3

23|3

15

220°03 62|362

310°0

3

23|3

15

40°03 62|362

TBM

Nail in K

erb

RL=3.01

StairsDrain

Stairs

Level Datum

Origin

Origin

Azimuth

Coord System

Notes DATE

JOB NO

AUTOCAD

CHECKED

SURVEYED

QT

Scale

Title

County of

Parish of

Client

ByDateAmendments & AdditionsNo

GEOCOMP

Sheet Reference #of

A.C.N. 061 750 132

A.B.N. 53 841 801 835

GROUP SERVICES

MICHEL

Surfers Paradise

Facsimile 07 5538 5117

Telephone 07 5539 8244

QLD Australia 4217

3rd Level, 50 Cavill Avenue

Web Site www.michelservices.com.auEmail [email protected]

REGISTERED QUEENSLAND NEW SOUTH WALES

LAND, ENGINEERING & GPS SURVEYING

HYDROGRAPHIC SURVEYING

TOWN PLANNING SERVICES

LECHAIM PTY LTD

PLAN OF LEVEL & FEATURE SURVEYOF LOT 1 ON RP219316NO.67 ALLAMBIE AVENUEBROADBEACH WATERS

GILSTONWARD

1:200

RP219316AHD

PSM136701

RL=2.672

PLANE

N/A

11/8/2004

6506-16

6506-504

TC

864722

6506-50411

1 2 43 5 10 15 20 25m

Scale 1:150 - Lengths are in Metres

.This note is an integral part of this plan.

therefore be incomplete and/or erroneous.

Authority and have been noted accordingly on this plan. They may

have been plotted from the records (where available) of the relevant

field survey. If underground and not able to be so located, services

.Services shown on this plan have been located where possible by

field measurement and therefore could be subject to error.

of this survey and have been compiled from RP219316 and not by

.The title boundaries shown on this plan were not surveyed as part

purpose, particularly demolition, excavation or construction.

the purpose of DESIGN and must not be used for any other

from a combination of field survey and existing records for

.This plan was prepared for LECHAIM PTY LTD

IMPORTANT NOTE

(Accuracy is approximate +/- 25mm.)

be relied upon for any detailed design work.

.Location of house and garage is approximate only and should not

.Location of all trees is approximate only.

TO

WA

LL A

BO

VE

NOTES:* Discharge waste to connection point* Provide sediment control to site where req'd

* Meter box position T.B.C on site* All retaining walls by owner

* Discharge stormwater to TANK, where possible, all otherstormwater & overflow to kerb & channel

SITE PLAN - GROUND FLOOR

SCALE 1:200 SHEET 4 OF 88 JOB NUMBER - 5082

**NOTE** ALL STORMWATER & DRAINAGE TO BE IN COMPLIANCE WITH BCA PARTS 3.1.2. &3.5.2. AS WELL AS ASNZS3500* GUTTERS TO BE 125MM D-SECTION COLORBOND GUTTERS* 2 DOWNPIPES MAX. TO EACH 100mm STORMWATER PIPE, SUBSURFACE PIPES TO BE 100mmDIAMETER, ANY UNDERSLAB PIPING TO HAVE AN INSPECTION OPENING AT UPPER END, THENTO BE 100mm SEWER GRADE PIPING WITH NO JOINS UNDER SLAB.

** 1:5 MAX DRIVEWAY SLOPE TO LOCAL GOVERNMENTREQUIREMENTS AND STANDARDS **

Page 5: 22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm high and inaccordance with as 1926.1 proposed renovation for jr 090513 b roof deck

Phone (07) 55 203 022Fax (07) 55 203 033

PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219

ABN 73 097 995 616

BSA License No: 1129687Email: [email protected]

© Copyright reserved in part or whole. Writtendimensions take preference.

Contractor to verify dimensions.Notify designers of discrepancies.

Failure to do so shall voidthe designers responsibilities.

TH

IS D

ES

IGN

IS T

HE

EX

CLU

SIV

E P

RO

PE

RT

Y O

F S

TU

AR

T O

SM

AN

BU

ILD

ING

DE

SIG

NS

N.B

ALL

WR

ITT

EN

DIM

EN

SIO

NS

TA

KE

PR

EC

ED

EN

CE

OV

ER

SC

ALE

D S

IZE

SB

E W

AR

NE

D: S

UB

ST

ITU

TIO

N O

F A

NY

ST

RU

CT

UR

AL

ME

MB

ER

S, A

ND

OR

AN

Y V

AR

IAT

ION

TO

AN

Y P

AR

T O

F T

HE

DE

SIG

N W

ILL

VO

ID A

NY

RE

SP

ON

SIB

ILIT

IES

OF

ST

UA

RT

OS

MA

N B

UIL

DIN

G D

ES

IGN

S F

OR

TH

E S

TR

UC

TU

RA

L IN

TE

GR

ITY

AN

D P

ER

FO

RM

AN

CE

OF

TH

E B

UIL

DIN

G

CLIENT

PROJECT

JOB NUMBER

BUILDER

DRAWN BY CHECKED BY

DESIGN

DATE

SCALES AMENDMENTS

SHEET NUMBERof

MEMBER OF

CHARTEREDMEMBER OF

MEMBER OF

queensland inc.association of

building designers

KING

PROPOSED RENOVATION65

ALLAMBI AVEBROADBEACH WATERS

5082

JR

A 09/05/2013

D180613E230713F020813G130813H150813I 020913

SO

CUSTOM

1:100 @ A3

5 22

J030913K190913L240913M181013N081113

900

1 2 3 4 5 6 7 8

12345

250

3,73

070

3,80

025

0

8,10

02,

000

8,30

0

2503,600702,430701,000300

1,200705,4005,760250

2503,600703,500300

3204,2001,200 2,76

07,

100

20,400

8,1009002,7009006,2901,51025

04,

500

270

7,76

027

04,

500

250

30,250

10,1705,4004,9701,6002,5404,0601,510

2,0001,510

2505,980701,800701,7502502509502502,100702,3002501,600250

1,00070

970705,500250

701,

800

110

5,98

011

02,

380

701,

600

250

1105,3602302,0002703,510

250

3,20

070

1,13

070

3,13

025

0

5,30

03,

000

2,00

0

BED 2

BED 3

FAMILY

KITCHEN

L'DRY

GARAGEWORKSHOP

ENTRYLOUNGE

DINING

WIR

WC

PATIO

BED 1

ENS

BATH

ST

OR

AG

E

FLOOR AREASEXISTING:

LOWER LIVING AREA:UPPER LIVING AREA:GARAGE:

TOTAL:

280 sq.m86 sq.m

72.2 sq.m

438.2 sq.m

GROUND FLOOR EXISTING

SCALE 1:100

ELEVATIONS

4

3

2

1

Page 6: 22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm high and inaccordance with as 1926.1 proposed renovation for jr 090513 b roof deck

Phone (07) 55 203 022Fax (07) 55 203 033

PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219

ABN 73 097 995 616

BSA License No: 1129687Email: [email protected]

© Copyright reserved in part or whole. Writtendimensions take preference.

Contractor to verify dimensions.Notify designers of discrepancies.

Failure to do so shall voidthe designers responsibilities.

TH

IS D

ES

IGN

IS T

HE

EX

CLU

SIV

E P

RO

PE

RT

Y O

F S

TU

AR

T O

SM

AN

BU

ILD

ING

DE

SIG

NS

N.B

ALL

WR

ITT

EN

DIM

EN

SIO

NS

TA

KE

PR

EC

ED

EN

CE

OV

ER

SC

ALE

D S

IZE

SB

E W

AR

NE

D: S

UB

ST

ITU

TIO

N O

F A

NY

ST

RU

CT

UR

AL

ME

MB

ER

S, A

ND

OR

AN

Y V

AR

IAT

ION

TO

AN

Y P

AR

T O

F T

HE

DE

SIG

N W

ILL

VO

ID A

NY

RE

SP

ON

SIB

ILIT

IES

OF

ST

UA

RT

OS

MA

N B

UIL

DIN

G D

ES

IGN

S F

OR

TH

E S

TR

UC

TU

RA

L IN

TE

GR

ITY

AN

D P

ER

FO

RM

AN

CE

OF

TH

E B

UIL

DIN

G

CLIENT

PROJECT

JOB NUMBER

BUILDER

DRAWN BY CHECKED BY

DESIGN

DATE

SCALES AMENDMENTS

SHEET NUMBERof

MEMBER OF

CHARTEREDMEMBER OF

MEMBER OF

queensland inc.association of

building designers

KING

PROPOSED RENOVATION65

ALLAMBI AVEBROADBEACH WATERS

5082

JR

A 09/05/2013

D180613E230713F020813G130813H150813I 020913

SO

CUSTOM

1:100 @ A3

6 22

J030913K190913L240913M181013N081113

1 2 3 4 5 6 7 8

12345678

2,000

3,0407,970

902,950903,960703,600250

3,21

0

903,

120

902,

160

250

2,50

025

0

903,

500

704,

550

90

250 3,600 70 3,960 90

8,46

0

3,00

05,

460

905,

600

70

roof

fall

STUDY

roof

fall

roof fall

roof

fall

roof fall

FIRST FLOOR EXISTING

SCALE 1:100

ELEVATIONS

4

3

2

1

Page 7: 22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm high and inaccordance with as 1926.1 proposed renovation for jr 090513 b roof deck

Phone (07) 55 203 022Fax (07) 55 203 033

PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219

ABN 73 097 995 616

BSA License No: 1129687Email: [email protected]

© Copyright reserved in part or whole. Writtendimensions take preference.

Contractor to verify dimensions.Notify designers of discrepancies.

Failure to do so shall voidthe designers responsibilities.

TH

IS D

ES

IGN

IS T

HE

EX

CLU

SIV

E P

RO

PE

RT

Y O

F S

TU

AR

T O

SM

AN

BU

ILD

ING

DE

SIG

NS

N.B

ALL

WR

ITT

EN

DIM

EN

SIO

NS

TA

KE

PR

EC

ED

EN

CE

OV

ER

SC

ALE

D S

IZE

SB

E W

AR

NE

D: S

UB

ST

ITU

TIO

N O

F A

NY

ST

RU

CT

UR

AL

ME

MB

ER

S, A

ND

OR

AN

Y V

AR

IAT

ION

TO

AN

Y P

AR

T O

F T

HE

DE

SIG

N W

ILL

VO

ID A

NY

RE

SP

ON

SIB

ILIT

IES

OF

ST

UA

RT

OS

MA

N B

UIL

DIN

G D

ES

IGN

S F

OR

TH

E S

TR

UC

TU

RA

L IN

TE

GR

ITY

AN

D P

ER

FO

RM

AN

CE

OF

TH

E B

UIL

DIN

G

CLIENT

PROJECT

JOB NUMBER

BUILDER

DRAWN BY CHECKED BY

DESIGN

DATE

SCALES AMENDMENTS

SHEET NUMBERof

MEMBER OF

CHARTEREDMEMBER OF

MEMBER OF

queensland inc.association of

building designers

KING

PROPOSED RENOVATION65

ALLAMBI AVEBROADBEACH WATERS

5082

JR

A 09/05/2013

D180613E230713F020813G130813H150813I 020913

SO

CUSTOM

1:100 @ A3

7 22

J030913K190913L240913M181013N081113

21-1

2adh

21-1

2adh

900

06-24asw 12-21asw

1 2 3 4 5 6 7 8

12345

Remove all internal walls shown dashed

Demolish all existing garage/ workshop

External walls to be removed.Maintain stair landing support

Maintain portion of existing stairs

Existing columns to be removed/relocated. TBC by engineer

BED 2

BED 3

FAMILY

KITCHEN

L'DRY

GARAGEWORKSHOP

ENTRYLOUNGE

DINING

WIR

WC

PATIO

BED 1

ENS

BATH

ST

OR

AG

E

GROUND FLOOR DEMOLITION PLAN

SCALE 1:100

Page 8: 22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm high and inaccordance with as 1926.1 proposed renovation for jr 090513 b roof deck

Phone (07) 55 203 022Fax (07) 55 203 033

PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219

ABN 73 097 995 616

BSA License No: 1129687Email: [email protected]

© Copyright reserved in part or whole. Writtendimensions take preference.

Contractor to verify dimensions.Notify designers of discrepancies.

Failure to do so shall voidthe designers responsibilities.

TH

IS D

ES

IGN

IS T

HE

EX

CLU

SIV

E P

RO

PE

RT

Y O

F S

TU

AR

T O

SM

AN

BU

ILD

ING

DE

SIG

NS

N.B

ALL

WR

ITT

EN

DIM

EN

SIO

NS

TA

KE

PR

EC

ED

EN

CE

OV

ER

SC

ALE

D S

IZE

SB

E W

AR

NE

D: S

UB

ST

ITU

TIO

N O

F A

NY

ST

RU

CT

UR

AL

ME

MB

ER

S, A

ND

OR

AN

Y V

AR

IAT

ION

TO

AN

Y P

AR

T O

F T

HE

DE

SIG

N W

ILL

VO

ID A

NY

RE

SP

ON

SIB

ILIT

IES

OF

ST

UA

RT

OS

MA

N B

UIL

DIN

G D

ES

IGN

S F

OR

TH

E S

TR

UC

TU

RA

L IN

TE

GR

ITY

AN

D P

ER

FO

RM

AN

CE

OF

TH

E B

UIL

DIN

G

CLIENT

PROJECT

JOB NUMBER

BUILDER

DRAWN BY CHECKED BY

DESIGN

DATE

SCALES AMENDMENTS

SHEET NUMBERof

MEMBER OF

CHARTEREDMEMBER OF

MEMBER OF

queensland inc.association of

building designers

KING

PROPOSED RENOVATION65

ALLAMBI AVEBROADBEACH WATERS

5082

JR

A 09/05/2013

D180613E230713F020813G130813H150813I 020913

SO

CUSTOM

1:100 @ A3

8 22

J030913K190913L240913M181013N081113

03-24afg 03-24afg

15-3

0asw

21-0

9alw

21-3

0sta

cke r

06-0

6alw

06-0

6alw

03-09asw03-15afg

1 2 3 4 5 6 7 8

12345678

Portion of existing roofs to be removedRemove all internal walls shown dashed

New window openings

roof

fall

STUDY

roof

fall

roof fall

roof

fall

roof fall

FIRST FLOOR DEMOLITION PLAN

SCALE 1:100

Page 9: 22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm high and inaccordance with as 1926.1 proposed renovation for jr 090513 b roof deck

Pho

ne

(07)

55

203

022

Fax

(07

) 55

203

033

PO

Box

284

5 B

urle

igh

Hea

ds D

C Q

ld 4

220

Add

ress

: 2/7

1 T

ow

nsh

ip D

rive

, Wes

t Bur

leig

h, Q

LD 4

219

AB

N 7

3 09

7 99

5 6

16B

SA

Lic

ens

e N

o: 1

1296

87

Em

ail:

desi

gn@

sobd

.net

© C

opyr

igh t

res

erve

d in

par

t or

who

le. W

ritte

ndi

men

sion

s ta

ke p

refe

renc

e.C

ontr

acto

r to

ver

ify d

imen

sion

s.N

otify

des

igne

rs o

f dis

crep

anci

es.

Fai

lure

to d

o so

sha

ll vo

idth

e de

sign

e rs

resp

onsi

bilit

ies.

THIS DESIGN IS THE EXCLUSIVE PROPERTY OF STUART OSMAN BUILDING DESIGNSN.B ALL WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED SIZES

BE WARNED: SUBSTITUTION OF ANY STRUCTURAL MEMBERS, AND OR ANY VARIATION TO ANY PART OF THE DESIGN WILL VOID ANYRESPONSIBILITIES OF STUART OSMAN BUILDING DESIGNS FOR THE STRUCTURAL INTEGRITY AND PERFORMANCE OF THE BUILDING

CLI

EN

T

PR

OJE

CT

JOB

NU

MB

ER

BU

ILD

ER

DR

AW

N B

YC

HE

CK

ED

BY

DE

SIG

N

DA

TE

SC

ALE

SA

ME

ND

ME

NT

S

SH

EE

T N

UM

BE

Rof

ME

MB

ER

OF C

HA

RT

ER

ED

ME

MB

ER

OF

ME

MB

ER

OF

quee

nsla

nd in

c.as

soci

atio

n of

build

ing

desi

gner

s

KIN

G

PR

OP

OS

ED

RE

NO

VA

TIO

N

65

AL

LAM

BI

AV

EB

RO

AD

BE

AC

H W

AT

ER

S

5082

JR A

09/0

5/2

013

SO

CU

STO

M

1:10

0 @

A3

92

2

D1

80

61

3E

23

07

13

F0

20

81

3G

13

08

13

H1

50

81

3I

02

09

13

J0

30

91

3K

19

09

13

L2

40

91

3M

18

10

13

N0

8111

3

21-1

2adh

21-1

2adh

06-24asw 12-21asw

820

24-48 panelift door 24-48 panelift door

820

04-2

7afg

21-0

6alw

21-0

6alw

04-15asw04-15asw

21-09afg 21-06afg

21-1

2adh

21-1

2adh

820

720

720

720

820

720

820

820

24-15SD

720

620 620

820

12-21asw72

072

0

1 2 3 4 5 6 7 8

12345 1 2 3 4 5

REF.

W.M.PROV

DWPROV

D.P

REF.

D.PD.P

D.P

190

5,29

070

1,25

519

03,

305

250

3,46

570

530

703,

465

250

4,290 4,570 8,340

4,840 70 4,280 90 2,000 70 2,000 90 4,280 190610

70 13,740 190

20 3,920 70 5,760 250

70 3,320 70 1,860 70 1,600 70 2,250 70 1,325 70 4,365 250

250

2,16

090

2,20

070

2,86

070

2,40

025

0

450

70

300 2,000 300

580

400

500

400

580

1,00

0

190 6,080 190

2,000 2,280 2,000

250

2,39

070

1,60

070

1,10

070

750

2,100

110

490

660 690

2301,970

4703,605

2305,670

2305,670

2301,065

5,00

0

1,16

02,

410

620

1,10

0

Glass balustrade

1100 high wall

Cabinetry wall

24-20 customcavity sliding doors

New stairs & patio slab extension

Frame aroundexisting column

470 sq masonry columns with polished concrete base

Continue bulkhead over kitchen

Double Brick250mm

GAMES

LOUNGEPATIO

KITCHEN

ENTRY

DINING

PORCH

4 CAR GARAGE

L'DRYFW

FW

BED 2BED 3

OFFICE 2

OFFICE 1

FAMILY

TV

. ful

l wal

l cab

inet

ry

ROBE

desk

1100

hig

h

1000 high B'fast bar

SPA

Rai

sed

gard

en b

ed

Pool pumpshed

Raised garden bed

garden

SHSpost

SHSpost

POND

1100

hig

h

mirror

shelf

storage

glas

s ba

lus t

rade

Ver

gola

roof

ove

r

void over

built in bench built in bench

24-7

4 st

ack e

r

PDR

stor

age

SHSpost

SHSpost

FW

CS

D

iron desk

cupboards

TV

full

ht b

ooks

helf/

bed

head

ROBEC

SD

900

wid

eco

okto

p

FW

ST

OR

AG

E

D22

A 20B 20

A 20B 20

C21

FLOOR AREASEXISTING:

LOWER LIVING AREA:UPPER LIVING AREA:GARAGE:

TOTAL:

280 sq.m86 sq.m

72.2 sq.m

438.2 sq.m

FLOOR AREASPROPOSED EXTENSION:

LOWER LIVING EXTENSION:UPPER LIVING EXTENSION:GARAGE:PORCH:PATIO:TILED ROOF TERRACE:GATEHOUSE:

TOTAL:

77.47 sq.m49.77 sq.m

115.39 sq.m5.16 sq.m

23.86 sq.m96.17 sq.m7.29 sq.m

375.11 sq.m

NOTES:* Lift off hinges to WC door, as per BCA 3.8.3* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be tinted* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be heat pump, solar or gas*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Bedroom windows w. 2m fall height from FL to groundbelow must comply with N.C.C 3.9.2.5. To be fitted withnon-removable screens or restricted to 125mm opening

GROUND FLOOR PLAN PROPOSED

SCALE 1:100

ELEVATIONS

4

3

2

1

Page 10: 22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm high and inaccordance with as 1926.1 proposed renovation for jr 090513 b roof deck

Phone (07) 55 203 022Fax (07) 55 203 033

PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219

ABN 73 097 995 616

BSA License No: 1129687Email: [email protected]

© Copyright reserved in part or whole. Writtendimensions take preference.

Contractor to verify dimensions.Notify designers of discrepancies.

Failure to do so shall voidthe designers responsibilities.

TH

IS D

ES

IGN

IS T

HE

EX

CLU

SIV

E P

RO

PE

RT

Y O

F S

TU

AR

T O

SM

AN

BU

ILD

ING

DE

SIG

NS

N.B

ALL

WR

ITT

EN

DIM

EN

SIO

NS

TA

KE

PR

EC

ED

EN

CE

OV

ER

SC

ALE

D S

IZE

SB

E W

AR

NE

D: S

UB

ST

ITU

TIO

N O

F A

NY

ST

RU

CT

UR

AL

ME

MB

ER

S, A

ND

OR

AN

Y V

AR

IAT

ION

TO

AN

Y P

AR

T O

F T

HE

DE

SIG

N W

ILL

VO

ID A

NY

RE

SP

ON

SIB

ILIT

IES

OF

ST

UA

RT

OS

MA

N B

UIL

DIN

G D

ES

IGN

S F

OR

TH

E S

TR

UC

TU

RA

L IN

TE

GR

ITY

AN

D P

ER

FO

RM

AN

CE

OF

TH

E B

UIL

DIN

G

CLIENT

PROJECT

JOB NUMBER

BUILDER

DRAWN BY CHECKED BY

DESIGN

DATE

SCALES AMENDMENTS

SHEET NUMBERof

MEMBER OF

CHARTEREDMEMBER OF

MEMBER OF

queensland inc.association of

building designers

KING

PROPOSED RENOVATION65

ALLAMBI AVEBROADBEACH WATERS

5082

JR

A 09/05/2013

D180613E230713F020813G130813H150813I 020913

SO

CUSTOM

1:100 @ A3

10 22

J030913K190913L240913M181013N081113

70

2,000

2,500 450450

450 3,150 200

1,000 6,000 1,200

12,0

00

3,800 2,200 1,200 750

2,100

110

490

2,00

02,

000

2,00

0

6,00

06,

000

5,00

0

1200 high pool fence

2m high boundary fence

Relocated ramp to pontoon

Raised garden/ water feature

New 'vergola'roof over

Line of existing pool

Tiered spill edge waterfeature to pool builders spec

New stairs & patio slab extension

Continue bulkhead over kitchen

3.40

2.27

3.55

3.40

3.34

3.34

2.5

7

2.57

3.4

0 3.38

3.38

1.58

1.55

2.27

2.38

2.54

2.46

2.65

2.44

1.27 2.43 2.49

2.50 2.50

2.44

2.50 2.50

2.52

2.51 2.51

2.50

2.53

2.53

2.51

2.5

1

2.52

2.29 2.29

2.23 2.27

2.30

2.20

2.30

2.29

2.26

2.26

2.46

1.73

1.69

1.23

1.24

0.66

0.66

0.65

0.64

0.62

0.63

0.65 0.65

1.53

0.17 0.08

1.52

1.38

2.30

2.52 2.24

2.50

2.39

2.35

2.55

2.44

2.49

2.72

2.5

8

2.58

2.78

2.54 2.47

2.52

2.76 3.78

3.79 3.96

3.95 3.95

2.58

2.54

2.54

2.56 2.56 3.21

3.21

2.5

3 2.64

2.53

2.50 2.86

3.22

3.24

3.22

3.18

3.24

3.21

1.63

Timber Jetty

Boat Ramp

Floating

Pontoon

Conc

Pavers

Drain

Pavers

Pavers

Pavers

Drain

Drain

Drain

Concrete Area

(Boat Storage)

Drain

GAMES

PATIO

DINING

1100

hig

h

BOAT RAMP

SPA

Rai

sed

gard

en b

ed

Pool pumpshed

feat

ure

wat

erfa

llRaised garden bed

POOL

garden

garden

SHSpost

SHSpost

POND

500

high

1000

hig

h

1500

hig

h

1800

hig

h

1200 high

glas

s ba

lust

rade

Ver

gola

roof

ove

r

24-7

4 st

acke

r

SHSpost

SHSpost

D22

C21

NOTES:* Lift off hinges to WC door, as per BCA 3.8.3* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be tinted* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be heat pump, solar or gas*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Bedroom windows w. 2m fall height from FL to groundbelow must comply with N.C.C 3.9.2.5. To be fitted withnon-removable screens or restricted to 125mm opening

GROUND FLOOR PLAN PROPOSED EXTERNAL

SCALE 1:100

ELEVATIONS

4

3

2

1

Page 11: 22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm high and inaccordance with as 1926.1 proposed renovation for jr 090513 b roof deck

Pho

ne

(07)

55

203

022

Fax

(07

) 55

203

033

PO

Box

284

5 B

urle

igh

Hea

ds D

C Q

ld 4

220

Add

ress

: 2/7

1 T

ow

nsh

ip D

rive

, Wes

t Bur

leig

h, Q

LD 4

219

AB

N 7

3 09

7 99

5 6

16B

SA

Lic

ens

e N

o: 1

1296

87

Em

ail:

desi

gn@

sobd

.net

© C

opyr

ight

res

erve

d in

par

t or

who

le. W

ritte

ndi

men

sion

s ta

ke p

refe

renc

e.C

ontr

acto

r to

ver

ify d

imen

sion

s.N

otify

des

igne

rs o

f dis

crep

anci

es.

Fai

lure

to d

o so

sha

ll vo

idth

e de

sign

ers

resp

onsi

bilit

ies.

THIS DESIGN IS THE EXCLUSIVE PROPERTY OF STUART OSMAN BUILDING DESIGNSN.B ALL WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED SIZES

BE WARNED: SUBSTITUTION OF ANY STRUCTURAL MEMBERS, AND OR ANY VARIATION TO ANY PART OF THE DESIGN WILL VOID ANYRESPONSIBILITIES OF STUART OSMAN BUILDING DESIGNS FOR THE STRUCTURAL INTEGRITY AND PERFORMANCE OF THE BUILDING

CLI

EN

T

PR

OJE

CT

JOB

NU

MB

ER

BU

ILD

ER

DR

AW

N B

YC

HE

CK

ED

BY

DE

SIG

N

DA

TE

SC

ALE

SA

ME

ND

ME

NT

S

SH

EE

T N

UM

BE

Rof

ME

MB

ER

OF C

HA

RT

ER

ED

ME

MB

ER

OF

ME

MB

ER

OF

quee

nsla

nd in

c.as

soci

atio

n of

build

ing

desi

gner

s

KIN

G

PR

OP

OS

ED

RE

NO

VA

TIO

N

65

AL

LAM

BI

AV

EB

RO

AD

BE

AC

H W

AT

ER

S

5082

JR A

09/0

5/2

013

SO

CU

STO

M

1:10

0 @

A3

11

22

D1

80

61

3E

23

07

13

F0

20

81

3G

13

08

13

H1

50

81

3I

02

09

13

J0

30

91

3K

19

09

13

L2

40

91

3M

18

10

13

N0

8111

3

03-24afg 03-24afg

820

15-3

0asw

21-0

9alw

21-3

0sta

cker

06-0

6alw

06-0

6alw

03-09asw03-15afg

820

09-2

7afg

03-24afg

820

09-27afg

720

06-09asw 06-09asw

820

21-18SD

720720

24-4

8sta

cker

1 2 3 4 5 6 7 8

12345678 1 2 3 4 5 6 7 8

D.P

D.PD.P

REF.

D.P

D.P

D.P

D.P

250 4,500 70 2,230 70

901,

215

703,

625

701,

870

701,

200

90

70 2,000 70 2,275 70100

70 4,550 350

250 3,630 70 2,000 70 1,860 90

1,500703,

140

90

500

70 1,242 1,860 1,243 70

70 2,350 250

701,

100

705,

065

230

C21

1m high renderedblockwork parapet wall

Tiled hob

Low level cavity slider

Storage cupboards in roof space

New 'vergola' roof

Glass balustrade

Soaker tray

Bulkhead around roof beam

Recess for builtin fold down bed

Low level cavity slider

Floor wate to connect to DP

Timber or aluminium batten screenwith perspex panel fixed to inside

Strip drain to perimeter

Timber or aluminium battenscreen recessed into parapet wall

roof

fall

ENS

MASTER BED

VOID

TILED ROOF DECKroof

fall

roof

fall

roof

fall

roof fall

roof

fall

roof fall

WIR

GYM

fall

1/2 height wall with shutters over

mirror

mirr

or

TV

desk

STOREBBQ

FW

FW

FW

falls to floor waste

D22

A 20B 20

A 20B 20

1933

mm

PR

ES

IDE

NT

Spa

NOTES:* Lift off hinges to WC door, as per BCA 3.8.3* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be tinted* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be heat pump, solar or gas*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Bedroom windows w. 2m fall height from FL to groundbelow must comply with N.C.C 3.9.2.5. To be fitted withnon-removable screens or restricted to 125mm opening

FIRST FLOOR PLAN PROPOSED

SCALE 1:100

ELEVATIONS

4

3

2

1

Page 12: 22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm high and inaccordance with as 1926.1 proposed renovation for jr 090513 b roof deck

Pho

ne

(07)

55

203

022

Fax

(07

) 55

203

033

PO

Box

284

5 B

urle

igh

Hea

ds D

C Q

ld 4

220

Add

ress

: 2/7

1 T

ow

nsh

ip D

rive

, Wes

t Bur

leig

h, Q

LD 4

219

AB

N 7

3 09

7 99

5 6

16B

SA

Lic

ens

e N

o: 1

1296

87

Em

ail:

desi

gn@

sobd

.net

© C

opyr

ight

res

erve

d in

par

t or

who

le. W

ritte

ndi

men

sion

s ta

ke p

refe

renc

e.C

ontr

acto

r to

ver

ify d

imen

sion

s.N

otify

des

igne

rs o

f dis

crep

anci

es.

Fai

lure

to d

o so

sha

ll vo

idth

e de

sign

ers

resp

onsi

bilit

ies.

THIS DESIGN IS THE EXCLUSIVE PROPERTY OF STUART OSMAN BUILDING DESIGNSN.B ALL WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED SIZES

BE WARNED: SUBSTITUTION OF ANY STRUCTURAL MEMBERS, AND OR ANY VARIATION TO ANY PART OF THE DESIGN WILL VOID ANYRESPONSIBILITIES OF STUART OSMAN BUILDING DESIGNS FOR THE STRUCTURAL INTEGRITY AND PERFORMANCE OF THE BUILDING

CLI

EN

T

PR

OJE

CT

JOB

NU

MB

ER

BU

ILD

ER

DR

AW

N B

YC

HE

CK

ED

BY

DE

SIG

N

DA

TE

SC

ALE

SA

ME

ND

ME

NT

S

SH

EE

T N

UM

BE

Rof

ME

MB

ER

OF C

HA

RT

ER

ED

ME

MB

ER

OF

ME

MB

ER

OF

quee

nsla

nd in

c.as

soci

atio

n of

build

ing

desi

gner

s

KIN

G

PR

OP

OS

ED

RE

NO

VA

TIO

N

65

AL

LAM

BI

AV

EB

RO

AD

BE

AC

H W

AT

ER

S

5082

JR A

09/0

5/2

013

SO

CU

STO

M

1:10

0 @

A3

12

22

D1

80

61

3E

23

07

13

F0

20

81

3G

13

08

13

H1

50

81

3I

02

09

13

J0

30

91

3K

19

09

13

L2

40

91

3M

18

10

13

N0

8111

3

D.P

D.P

D.P

D.P

C21

20 degree concrete tileroof to match existing

Stramit colorbond fascias,gutters & downpipes

Extent of new roofs shown hatched

roof

fall

roof fall

roof

fall

roof fall

roof

fall

roof fall

roof fall

roof

fall

roof

fall

roof fallD22

A 20B 20

A 20B 20

* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be tinted* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be heat pump, solar or gas*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Bedroom windows w. 2m fall height from FL to groundbelow must comply with N.C.C 3.9.2.5. To be fitted withnon-removable screens or restricted to 125mm opening

ROOF PLAN

SCALE 1:100

ELEVATIONS

4

3

2

1

Page 13: 22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm high and inaccordance with as 1926.1 proposed renovation for jr 090513 b roof deck

Pho

ne

(07)

55

203

022

Fax

(07

) 55

203

033

PO

Box

284

5 B

urle

igh

Hea

ds D

C Q

ld 4

220

Add

ress

: 2/7

1 T

ow

nsh

ip D

rive

, Wes

t Bur

leig

h, Q

LD 4

219

AB

N 7

3 09

7 99

5 6

16B

SA

Lic

ens

e N

o: 1

1296

87

Em

ail:

desi

gn@

sobd

.net

© C

opyr

ight

res

erve

d in

par

t or

who

le. W

ritte

ndi

men

sion

s ta

ke p

refe

renc

e.C

ontr

acto

r to

ver

ify d

imen

sion

s.N

otify

des

igne

rs o

f dis

crep

anci

es.

Fai

lure

to d

o so

sha

ll vo

idth

e de

sign

ers

resp

onsi

bilit

ies.

THIS DESIGN IS THE EXCLUSIVE PROPERTY OF STUART OSMAN BUILDING DESIGNSN.B ALL WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED SIZES

BE WARNED: SUBSTITUTION OF ANY STRUCTURAL MEMBERS, AND OR ANY VARIATION TO ANY PART OF THE DESIGN WILL VOID ANYRESPONSIBILITIES OF STUART OSMAN BUILDING DESIGNS FOR THE STRUCTURAL INTEGRITY AND PERFORMANCE OF THE BUILDING

CLI

EN

T

PR

OJE

CT

JOB

NU

MB

ER

BU

ILD

ER

DR

AW

N B

YC

HE

CK

ED

BY

DE

SIG

N

DA

TE

SC

ALE

SA

ME

ND

ME

NT

S

SH

EE

T N

UM

BE

Rof

ME

MB

ER

OF C

HA

RT

ER

ED

ME

MB

ER

OF

ME

MB

ER

OF

quee

nsla

nd in

c.as

soci

atio

n of

build

ing

desi

gner

s

KIN

G

PR

OP

OS

ED

RE

NO

VA

TIO

N

65

AL

LAM

BI

AV

EB

RO

AD

BE

AC

H W

AT

ER

S

5082

JR A

09/0

5/2

013

SO

CU

STO

M

1:10

0 @

A3

13

22

D1

80

61

3E

23

07

13

F0

20

81

3G

13

08

13

H1

50

81

3I

02

09

13

J0

30

91

3K

19

09

13

L2

40

91

3M

18

10

13

N0

8111

3

2,98

02,

700

2,40

02,

700

Infill existing openings New rendered blockwork garage walls

20 degree concrete tileroof to match existing

Existing 20 degree concrete tile roof

Powder coated aluminium shutters

Floor slab with 50mm drip edge

Rendered harditexto match existing

New brick veneer wall to match existingLine of existing roof Powdercoated aluminium

windows & SGDs

Stramit colorbond fascias,gutters & downpipes

New 'vergola' roof tomanufacturers spec

Coulrbond Flashing

FL

FL

FL FLCL CL

CL

CL

20° pitch

fg fg fg

ELEVATION 1 1:100

1,80

0

Rendered masonry raisedgarden/ water feature

Pool pump shed

Tiered spill edge waterfeature to pool builders spec

ELEVATION 1 cont 1:100

NOTES:* Lift off hinges to WC door, as per BCA 3.8.3* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be tinted* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be heat pump, solar or gas*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Bedroom windows w. 2m fall height from FL to groundbelow must comply with N.C.C 3.9.2.5. To be fitted withnon-removable screens or restricted to 125mm opening

Page 14: 22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm high and inaccordance with as 1926.1 proposed renovation for jr 090513 b roof deck

Pho

ne

(07)

55

203

022

Fax

(07

) 55

203

033

PO

Box

284

5 B

urle

igh

Hea

ds D

C Q

ld 4

220

Add

ress

: 2/7

1 T

ow

nsh

ip D

rive

, Wes

t Bur

leig

h, Q

LD 4

219

AB

N 7

3 09

7 99

5 6

16B

SA

Lic

ens

e N

o: 1

1296

87

Em

ail:

desi

gn@

sobd

.net

© C

opyr

ight

res

erve

d in

par

t or

who

le. W

ritte

ndi

men

sion

s ta

ke p

refe

renc

e.C

ontr

acto

r to

ver

ify d

imen

sion

s.N

otify

des

igne

rs o

f dis

crep

anci

es.

Fai

lure

to d

o so

sha

ll vo

idth

e de

sign

ers

resp

onsi

bilit

ies.

THIS DESIGN IS THE EXCLUSIVE PROPERTY OF STUART OSMAN BUILDING DESIGNSN.B ALL WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED SIZES

BE WARNED: SUBSTITUTION OF ANY STRUCTURAL MEMBERS, AND OR ANY VARIATION TO ANY PART OF THE DESIGN WILL VOID ANYRESPONSIBILITIES OF STUART OSMAN BUILDING DESIGNS FOR THE STRUCTURAL INTEGRITY AND PERFORMANCE OF THE BUILDING

CLI

EN

T

PR

OJE

CT

JOB

NU

MB

ER

BU

ILD

ER

DR

AW

N B

YC

HE

CK

ED

BY

DE

SIG

N

DA

TE

SC

ALE

SA

ME

ND

ME

NT

S

SH

EE

T N

UM

BE

Rof

ME

MB

ER

OF C

HA

RT

ER

ED

ME

MB

ER

OF

ME

MB

ER

OF

quee

nsla

nd in

c.as

soci

atio

n of

build

ing

desi

gner

s

KIN

G

PR

OP

OS

ED

RE

NO

VA

TIO

N

65

AL

LAM

BI

AV

EB

RO

AD

BE

AC

H W

AT

ER

S

5082

JR A

09/0

5/2

013

SO

CU

STO

M

1:10

0 @

A3

14

22

D1

80

61

3E

23

07

13

F0

20

81

3G

13

08

13

H1

50

81

3I

02

09

13

J0

30

91

3K

19

09

13

L2

40

91

3M

18

10

13

N0

8111

3

2,70

02,

400

2,50

070

060

0

2,98

0

900

380

2,70

0

New rendered blockwork garage walls

20 degree concrete tileroof to match existing

Floor slab with50mm drip edge

Powdercoated aluminiumwindows & SGDs

Stramit colorbond fascias,gutters & downpipes

Timber or aluminium batten screenwith perspex panel fixed to inside

Rendered harditex tomatch existing

Replace front widows

polished concrete base to masonry column

FL

FL

FL FL

CL CL

CL

CL

20° pitch

porch ceiling

fg fg

fg

batten screen

balustrade

ELEVATION 2 1:100

2,70

02,

400

2,70

02,

700

Existing structure

1200mm high pool fence,to AS 1926.1

1000mm high h/rail,as per BCA 3.9.2

20 degree concrete tileroof to match existing

New powdercoated aluminiumwindows & SGDs to existing structure

New 'vergola' roof tomanufacturers spec

Rendered harditex tomatch existing

New tiled stairs to pool area

FLFL

FLFLCLCL

CL

CL

20° pitch

ELEVATION 4 1:100

NOTES:* Lift off hinges to WC door, as per BCA 3.8.3* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be tinted* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be heat pump, solar or gas*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Bedroom windows w. 2m fall height from FL to groundbelow must comply with N.C.C 3.9.2.5. To be fitted withnon-removable screens or restricted to 125mm opening

Page 15: 22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm high and inaccordance with as 1926.1 proposed renovation for jr 090513 b roof deck

Pho

ne

(07)

55

203

022

Fax

(07

) 55

203

033

PO

Box

284

5 B

urle

igh

Hea

ds D

C Q

ld 4

220

Add

ress

: 2/7

1 T

ow

nsh

ip D

rive

, Wes

t Bur

leig

h, Q

LD 4

219

AB

N 7

3 09

7 99

5 6

16B

SA

Lic

ens

e N

o: 1

1296

87

Em

ail:

desi

gn@

sobd

.net

© C

opyr

ight

res

erve

d in

par

t or

who

le. W

ritte

ndi

men

sion

s ta

ke p

refe

renc

e.C

ontr

acto

r to

ver

ify d

imen

sion

s.N

otify

des

igne

rs o

f dis

crep

anci

es.

Fai

lure

to d

o so

sha

ll vo

idth

e de

sign

ers

resp

onsi

bilit

ies.

THIS DESIGN IS THE EXCLUSIVE PROPERTY OF STUART OSMAN BUILDING DESIGNSN.B ALL WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED SIZES

BE WARNED: SUBSTITUTION OF ANY STRUCTURAL MEMBERS, AND OR ANY VARIATION TO ANY PART OF THE DESIGN WILL VOID ANYRESPONSIBILITIES OF STUART OSMAN BUILDING DESIGNS FOR THE STRUCTURAL INTEGRITY AND PERFORMANCE OF THE BUILDING

CLI

EN

T

PR

OJE

CT

JOB

NU

MB

ER

BU

ILD

ER

DR

AW

N B

YC

HE

CK

ED

BY

DE

SIG

N

DA

TE

SC

ALE

SA

ME

ND

ME

NT

S

SH

EE

T N

UM

BE

Rof

ME

MB

ER

OF C

HA

RT

ER

ED

ME

MB

ER

OF

ME

MB

ER

OF

quee

nsla

nd in

c.as

soci

atio

n of

build

ing

desi

gner

s

KIN

G

PR

OP

OS

ED

RE

NO

VA

TIO

N

65

AL

LAM

BI

AV

EB

RO

AD

BE

AC

H W

AT

ER

S

5082

JR A

09/0

5/2

013

SO

CU

STO

M

1:10

0 @

A3

15

22

D1

80

61

3E

23

07

13

F0

20

81

3G

13

08

13

H1

50

81

3I

02

09

13

J0

30

91

3K

19

09

13

L2

40

91

3M

18

10

13

N0

8111

3

2,70

02,

700

2,70

02,

400

900

Infill existing openings

Existing pergola

1200mm high FG pool fence,to AS 1926.1

20 degree concrete tileroof to match existing

Timber or aluminium batten screenwith perspex panel fixed to inside

Powdercoated aluminiumwindows & SGDs

Rendered brick veneerto match existing

New rendered blockwork garage walls

600 wide renderedfoam hood

Existing stairs & boat store

New brick veneer wall to match existing.Partial infill of steps

Rendered masonry columns with polished concrete base

FL

FLCL

CL

20° pitch

fg fg fg

ELEVATION 3 1:100

2,72

0

1,80

020 degree concrete tileroof to match house

Rendered masonry front fence

76sq SHS posts

Letterbox

FL

CL

FL

CL

ELEVATION 5 - GATEHOUSE 1:100

190 2,820 190

190

2,32

019

01,

200

190

2,00

019

0

2,70

0

900190

1,210190

500

E11

E11

Letterbox

Intercom

GATEHOUSE 1:100

2,72

0

490

20 degree concrete tileroof to match house

Rendered masonry front fence

76sq SHS posts

Intercom

Stramit colorbond fascias,gutters & downpipes

FL

CL

FL

CL

SECTION 1:100

9E

inc 40fascia

NOTES:* Lift off hinges to WC door, as per BCA 3.8.3* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be tinted* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be heat pump, solar or gas*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Bedroom windows w. 2m fall height from FL to groundbelow must comply with N.C.C 3.9.2.5. To be fitted withnon-removable screens or restricted to 125mm opening

Page 16: 22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm high and inaccordance with as 1926.1 proposed renovation for jr 090513 b roof deck

Pho

ne

(07)

55

203

022

Fax

(07

) 55

203

033

PO

Box

284

5 B

urle

igh

Hea

ds D

C Q

ld 4

220

Add

ress

: 2/7

1 T

ow

nsh

ip D

rive

, Wes

t Bur

leig

h, Q

LD 4

219

AB

N 7

3 09

7 99

5 6

16B

SA

Lic

ens

e N

o: 1

1296

87

Em

ail:

desi

gn@

sobd

.net

© C

opyr

ight

res

erve

d in

par

t or

who

le. W

ritte

ndi

men

sion

s ta

ke p

refe

renc

e.C

ontr

acto

r to

ver

ify d

imen

sion

s.N

otify

des

igne

rs o

f dis

crep

anci

es.

Fai

lure

to d

o so

sha

ll vo

idth

e de

sign

ers

resp

onsi

bilit

ies.

THIS DESIGN IS THE EXCLUSIVE PROPERTY OF STUART OSMAN BUILDING DESIGNSN.B ALL WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED SIZES

BE WARNED: SUBSTITUTION OF ANY STRUCTURAL MEMBERS, AND OR ANY VARIATION TO ANY PART OF THE DESIGN WILL VOID ANYRESPONSIBILITIES OF STUART OSMAN BUILDING DESIGNS FOR THE STRUCTURAL INTEGRITY AND PERFORMANCE OF THE BUILDING

CLI

EN

T

PR

OJE

CT

JOB

NU

MB

ER

BU

ILD

ER

DR

AW

N B

YC

HE

CK

ED

BY

DE

SIG

N

DA

TE

SC

ALE

SA

ME

ND

ME

NT

S

SH

EE

T N

UM

BE

Rof

ME

MB

ER

OF C

HA

RT

ER

ED

ME

MB

ER

OF

ME

MB

ER

OF

quee

nsla

nd in

c.as

soci

atio

n of

build

ing

desi

gner

s

KIN

G

PR

OP

OS

ED

RE

NO

VA

TIO

N

65

AL

LAM

BI

AV

EB

RO

AD

BE

AC

H W

AT

ER

S

5082

JR A

09/0

5/2

013

SO

CU

STO

M

1:10

0 @

A3

16

22

D1

80

61

3E

23

07

13

F0

20

81

3G

13

08

13

H1

50

81

3I

02

09

13

J0

30

91

3K

19

09

13

L2

40

91

3M

18

10

13

N0

8111

3

21-1

2adh

21-1

2adh

06-24asw 12-21asw

820

24-48 panelift door 24-48 panelift door

820

04-2

7afg

21-0

6alw

21-0

6alw

04-15asw04-15asw

21-09afg 21-06afg

21-1

2adh

21-1

2adh

820

720

720

720

820

720

820

820

24-15SD

720

620 620

820

12-21asw72

072

0

1 2 3 4 5 6 7 8

12345 1 2 3 4 5

D.P

D.PD.P

D.P

TV

P.

to above

spp forREF

spp forDW

spp forREF

to above

P.P.

P.

P.

provide circuit for spa& pool lighting

circuit forvergola roof

GROUND FLOOR ELECTRICAL PLAN

SCALE 1:100

P.

ELECTRICAL LEGEND

TV

CEILING FAN LIGHT

PHONE OUTLET

2 GLOBE FAN, HEAT, LIGHT

METER BOX

SINGLE GPO'S - 1050 OFF FLOOR

SINGLE GPO'S - 300 OFF FLOOR

DOUBLE GPO'S - 300 OFF FLOOR

TV ANTENNA POINT

EXHAUST FAN

FLUORESCENT LIGHT

PHONE OUTLET-300 OFF FLOOR

CEILING FAN

DOWN LIGHT

WALL LIGHT

SMOKE DETECTOR

FLOOD LIGHT

PENCIL SPOT

SPECIAL LIGHT

SWITCH POINTS @ 1350 OFF FLOOR

DOUBLE GPO'S - 1050 OFF FLOOR

CEILING LIGHT (BATTEN HOLD)

NOTES:

* ALL external power points to be weather-proof

** ALL ELECTRICAL POINTS T.B.C ON SITE BYCLIENT AND ELECTRICIAN **

FP.FLUORESCENT PENCIL SPOT

PROVIDE 80% min. ENERGY EFFICIENT LIGHTINGAS PER QUEENSLAND DEVELOPMENT CODE GUIDELINES

Page 17: 22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm high and inaccordance with as 1926.1 proposed renovation for jr 090513 b roof deck

Pho

ne

(07)

55

203

022

Fax

(07

) 55

203

033

PO

Box

284

5 B

urle

igh

Hea

ds D

C Q

ld 4

220

Add

ress

: 2/7

1 T

ow

nsh

ip D

rive

, Wes

t Bur

leig

h, Q

LD 4

219

AB

N 7

3 09

7 99

5 6

16B

SA

Lic

ens

e N

o: 1

1296

87

Em

ail:

desi

gn@

sobd

.net

© C

opyr

ight

res

erve

d in

par

t or

who

le. W

ritte

ndi

men

sion

s ta

ke p

refe

renc

e.C

ontr

acto

r to

ver

ify d

imen

sion

s.N

otify

des

igne

rs o

f dis

crep

anci

es.

Fai

lure

to d

o so

sha

ll vo

idth

e de

sign

ers

resp

onsi

bilit

ies.

THIS DESIGN IS THE EXCLUSIVE PROPERTY OF STUART OSMAN BUILDING DESIGNSN.B ALL WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED SIZES

BE WARNED: SUBSTITUTION OF ANY STRUCTURAL MEMBERS, AND OR ANY VARIATION TO ANY PART OF THE DESIGN WILL VOID ANYRESPONSIBILITIES OF STUART OSMAN BUILDING DESIGNS FOR THE STRUCTURAL INTEGRITY AND PERFORMANCE OF THE BUILDING

CLI

EN

T

PR

OJE

CT

JOB

NU

MB

ER

BU

ILD

ER

DR

AW

N B

YC

HE

CK

ED

BY

DE

SIG

N

DA

TE

SC

ALE

SA

ME

ND

ME

NT

S

SH

EE

T N

UM

BE

Rof

ME

MB

ER

OF C

HA

RT

ER

ED

ME

MB

ER

OF

ME

MB

ER

OF

quee

nsla

nd in

c.as

soci

atio

n of

build

ing

desi

gner

s

KIN

G

PR

OP

OS

ED

RE

NO

VA

TIO

N

65

AL

LAM

BI

AV

EB

RO

AD

BE

AC

H W

AT

ER

S

5082

JR A

09/0

5/2

013

SO

CU

STO

M

1:10

0 @

A3

17

22

D1

80

61

3E

23

07

13

F0

20

81

3G

13

08

13

H1

50

81

3I

02

09

13

J0

30

91

3K

19

09

13

L2

40

91

3M

18

10

13

N0

8111

3

03-24afg 03-24afg

820

15-3

0asw

21-0

9alw

21-3

0sta

cker

06-0

6alw

06-0

6alw

03-09asw03-15afg

820

09-2

7afg

03-24afg

820

09-27afg

720

06-09asw 06-09asw

820

21-18SD

720720

24-4

8sta

cker

1 2 3 4 5 6 7 8

12345678 1 2 3 4 5 6 7 8

D.P

D.PD.P

D.P

D.P

D.P

D.P

roof

fall ro

of fa

ll

roof

fall

roof

fall

roof fall

roof

fall

roof fall

fall

to belowto below

TV

P.

P.

FIRST FLOOR ELECTRICAL PLAN

SCALE 1:100CLIENT WITH ELECTRICIANCONFIRMED ON SITE BYELECTRICAL LAYOUT TO BE

NOTES:

* ALL external power points to be weather-proof

** ALL ELECTRICAL POINTS T.B.C ON SITE BYCLIENT AND ELECTRICIAN **

PROVIDE 80% min. ENERGY EFFICIENT LIGHTINGAS PER QUEENSLAND DEVELOPMENT CODE GUIDELINES

P.

ELECTRICAL LEGEND

TV

CEILING FAN LIGHT

PHONE OUTLET

2 GLOBE FAN, HEAT, LIGHT

METER BOX

SINGLE GPO'S - 1050 OFF FLOOR

SINGLE GPO'S - 300 OFF FLOOR

DOUBLE GPO'S - 300 OFF FLOOR

TV ANTENNA POINT

EXHAUST FAN

FLUORESCENT LIGHT

PHONE OUTLET-300 OFF FLOOR

CEILING FAN

DOWN LIGHT

WALL LIGHT

SMOKE DETECTOR

FLOOD LIGHT

PENCIL SPOT

SPECIAL LIGHT

SWITCH POINTS @ 1350 OFF FLOOR

DOUBLE GPO'S - 1050 OFF FLOOR

CEILING LIGHT (BATTEN HOLD)

FP.FLUORESCENT PENCIL SPOT

Page 18: 22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm high and inaccordance with as 1926.1 proposed renovation for jr 090513 b roof deck

Pho

ne

(07)

55

203

022

Fax

(07

) 55

203

033

PO

Box

284

5 B

urle

igh

Hea

ds D

C Q

ld 4

220

Add

ress

: 2/7

1 T

ow

nsh

ip D

rive

, Wes

t Bur

leig

h, Q

LD 4

219

AB

N 7

3 09

7 99

5 6

16B

SA

Lic

ens

e N

o: 1

1296

87

Em

ail:

desi

gn@

sobd

.net

© C

opyr

ight

res

erve

d in

par

t or

who

le. W

ritte

ndi

men

sion

s ta

ke p

refe

renc

e.C

ontr

acto

r to

ver

ify d

imen

sion

s.N

otify

des

igne

rs o

f dis

crep

anci

es.

Fai

lure

to d

o so

sha

ll vo

idth

e de

sign

ers

resp

onsi

bilit

ies.

THIS DESIGN IS THE EXCLUSIVE PROPERTY OF STUART OSMAN BUILDING DESIGNSN.B ALL WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED SIZES

BE WARNED: SUBSTITUTION OF ANY STRUCTURAL MEMBERS, AND OR ANY VARIATION TO ANY PART OF THE DESIGN WILL VOID ANYRESPONSIBILITIES OF STUART OSMAN BUILDING DESIGNS FOR THE STRUCTURAL INTEGRITY AND PERFORMANCE OF THE BUILDING

CLI

EN

T

PR

OJE

CT

JOB

NU

MB

ER

BU

ILD

ER

DR

AW

N B

YC

HE

CK

ED

BY

DE

SIG

N

DA

TE

SC

ALE

SA

ME

ND

ME

NT

S

SH

EE

T N

UM

BE

Rof

ME

MB

ER

OF C

HA

RT

ER

ED

ME

MB

ER

OF

ME

MB

ER

OF

quee

nsla

nd in

c.as

soci

atio

n of

build

ing

desi

gner

s

KIN

G

PR

OP

OS

ED

RE

NO

VA

TIO

N

65

AL

LAM

BI

AV

EB

RO

AD

BE

AC

H W

AT

ER

S

5082

JR A

09/0

5/2

013

SO

CU

STO

M

1:10

0 @

A3

18

22

D1

80

61

3E

23

07

13

F0

20

81

3G

13

08

13

H1

50

81

3I

02

09

13

J0

30

91

3K

19

09

13

L2

40

91

3M

18

10

13

N0

8111

3

7,140 1,500 10,250

3,920 6,080

250

2,20

03,

000

2,40

025

0

9,050 8,150 6,4606,

995

3,30

511

0

250

2,39

0

420 4,070

2,00

012

,180

600

1,560 300 690

1,00

0

8,39

5

1,200 360

400

5,55

01,

255

190

470

2,50

569

0

190

300 14,800

490

New slab to match existing

New slab to match existingover stairs

Spa & water feature topool builders spec

Pad footing for 690 sq masonry column

Brick up base to match existing

Brick up base to match existing

Slab & footings toengineers design

HomeGuard termite protectionsystem to underside of slab,perimeter & penetrations, inaccordance with AS 3660.1

fw

fw

tub

fw

sink

sink

fw

shower

basinwc

sink

shower

basin

wc

shower

wc

basin

wet area

wet area

wet area

extent of new patio slab.

R.L. to m

atch existing patio

extent of new house slab

380mmstepdown

50mmstepdown

GROUND FLOOR SLAB PLAN

SCALE 1:100

NOTES:* Slab and Footings as per engineers designs* Provide Termite Protection as per AS 3660* ALL floor levels t.b.c on site* ALL floor joist to be specified by engineer

Page 19: 22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm high and inaccordance with as 1926.1 proposed renovation for jr 090513 b roof deck

Pho

ne

(07)

55

203

022

Fax

(07

) 55

203

033

PO

Box

284

5 B

urle

igh

Hea

ds D

C Q

ld 4

220

Add

ress

: 2/7

1 T

ow

nsh

ip D

rive

, Wes

t Bur

leig

h, Q

LD 4

219

AB

N 7

3 09

7 99

5 6

16B

SA

Lic

ens

e N

o: 1

1296

87

Em

ail:

desi

gn@

sobd

.net

© C

opyr

ight

res

erve

d in

par

t or

who

le. W

ritte

ndi

men

sion

s ta

ke p

refe

renc

e.C

ontr

acto

r to

ver

ify d

imen

sion

s.N

otify

des

igne

rs o

f dis

crep

anci

es.

Fai

lure

to d

o so

sha

ll vo

idth

e de

sign

ers

resp

onsi

bilit

ies.

THIS DESIGN IS THE EXCLUSIVE PROPERTY OF STUART OSMAN BUILDING DESIGNSN.B ALL WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED SIZES

BE WARNED: SUBSTITUTION OF ANY STRUCTURAL MEMBERS, AND OR ANY VARIATION TO ANY PART OF THE DESIGN WILL VOID ANYRESPONSIBILITIES OF STUART OSMAN BUILDING DESIGNS FOR THE STRUCTURAL INTEGRITY AND PERFORMANCE OF THE BUILDING

CLI

EN

T

PR

OJE

CT

JOB

NU

MB

ER

BU

ILD

ER

DR

AW

N B

YC

HE

CK

ED

BY

DE

SIG

N

DA

TE

SC

ALE

SA

ME

ND

ME

NT

S

SH

EE

T N

UM

BE

Rof

ME

MB

ER

OF C

HA

RT

ER

ED

ME

MB

ER

OF

ME

MB

ER

OF

quee

nsla

nd in

c.as

soci

atio

n of

build

ing

desi

gner

s

KIN

G

PR

OP

OS

ED

RE

NO

VA

TIO

N

65

AL

LAM

BI

AV

EB

RO

AD

BE

AC

H W

AT

ER

S

5082

JR A

09/0

5/2

013

SO

CU

STO

M

1:10

0 @

A3

19

22

D1

80

61

3E

23

07

13

F0

20

81

3G

13

08

13

H1

50

81

3I

02

09

13

J0

30

91

3K

19

09

13

L2

40

91

3M

18

10

13

N0

8111

3

1,700

2,50

0

500

1,590 4,570 14,800

2,600

190

1,16

02,

410

620

1,17

01,

255

190

3,30

525

0

50

1,00

045

0

8,39

5

8,290 6,320 190

5,55

01,

285

160

3,55

5

Extent of new slab tomatch existing

Blockwork walls below

50mm drip edge to slab

CantileveredSus. Slab

by engineer

Recess to suit batten screen

Slab falls toperimeter strip drain

Slab falls toperimeter strip drain

Block walls below

Block walls below

Double Brick 250mm wall below

spa

shower

basin

wc

wet area

fw

basin

fw

basin

wc

wet area

Existing slabExistingbalcony slab

fw

100mmstepdown

100m

mst

epdo

wn

FIRST FLOOR SLAB PLAN

SCALE 1:100

NOTES:* Slab and Footings as per engineers designs* Provide Termite Protection as per AS 3660* ALL floor levels t.b.c on site* ALL floor joist to be specified by engineer

Page 20: 22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm high and inaccordance with as 1926.1 proposed renovation for jr 090513 b roof deck

Phone (07) 55 203 022Fax (07) 55 203 033

PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219

ABN 73 097 995 616

BSA License No: 1129687Email: [email protected]

© Copyright reserved in part or whole. Writtendimensions take preference.

Contractor to verify dimensions.Notify designers of discrepancies.

Failure to do so shall voidthe designers responsibilities.

TH

IS D

ES

IGN

IS T

HE

EX

CLU

SIV

E P

RO

PE

RT

Y O

F S

TU

AR

T O

SM

AN

BU

ILD

ING

DE

SIG

NS

N.B

ALL

WR

ITT

EN

DIM

EN

SIO

NS

TA

KE

PR

EC

ED

EN

CE

OV

ER

SC

ALE

D S

IZE

SB

E W

AR

NE

D: S

UB

ST

ITU

TIO

N O

F A

NY

ST

RU

CT

UR

AL

ME

MB

ER

S, A

ND

OR

AN

Y V

AR

IAT

ION

TO

AN

Y P

AR

T O

F T

HE

DE

SIG

N W

ILL

VO

ID A

NY

RE

SP

ON

SIB

ILIT

IES

OF

ST

UA

RT

OS

MA

N B

UIL

DIN

G D

ES

IGN

S F

OR

TH

E S

TR

UC

TU

RA

L IN

TE

GR

ITY

AN

D P

ER

FO

RM

AN

CE

OF

TH

E B

UIL

DIN

G

CLIENT

PROJECT

JOB NUMBER

BUILDER

DRAWN BY CHECKED BY

DESIGN

DATE

SCALES AMENDMENTS

SHEET NUMBERof

MEMBER OF

CHARTEREDMEMBER OF

MEMBER OF

queensland inc.association of

building designers

KING

PROPOSED RENOVATION65

ALLAMBI AVEBROADBEACH WATERS

5082

JR

A 09/05/2013

D180613E230713F020813G130813H150813I 020913

SO

CUSTOM

1:100 @ A3

20 22

J030913K190913L240913M181013N081113

2,70

02,

400

Existing structure

600

760

Line of existing roof removed

Soaker tray

Existing roof structure

Slab & footings on compactedfill to engineers design

20 degree concrete tileroof to match existing

Plasterboard lining to walls & ceilings,villaboard lining to ALL wet areas

VOID

ENTRY OFFICE 2ROBEENS

STAIRS

FL

FLCL

CL

FL

FLCL

CL

SECTION 1:100

9B

BINDERS @ 3000 Ctrs.

BINDERS @ 3000 Ctrs.

20° pitch

to matchexisting

to matchexisting

20 degree roof trusses @ 600 ctrsas per truss manufacturers specification's

2,70

02,

400

76040200

2,70

02,

700

Existing structure

Stramit colorbond capping to topof all parapet walls, 1:100 fall backinto roof area, refer Parapet Details

Sus. Slab by engineer

Plasterboard lining to walls & ceilings,villaboard lining to ALL wet areas

Slab & footings on compactedfill to engineers design

HomeGuard termite protectionsystem to underside of slab,perimeter & penetrations, inaccordance with AS 3660.1

20 degree concrete tileroof to match existing

Block Wall by engineer

Block Wall by engineerDouble Brick250mm by engineer

Colorbond Flashing

SECTION 1:100

9A

FL

FLCL

CL

FL

FLCL

CLBINDERS @ 3000 Ctrs.

inc 40fascia

PORCHBED 2 OFFICE 2OFFICE 1

GYMSTORE

100mmstepdown

to matchexisting

fascia

20° pitch

20 degree roof trusses @ 600 ctrsas per truss manufacturers specification's

Page 21: 22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm high and inaccordance with as 1926.1 proposed renovation for jr 090513 b roof deck

Pho

ne

(07)

55

203

022

Fax

(07

) 55

203

033

PO

Box

284

5 B

urle

igh

Hea

ds D

C Q

ld 4

220

Add

ress

: 2/7

1 T

ow

nsh

ip D

rive

, Wes

t Bur

leig

h, Q

LD 4

219

AB

N 7

3 09

7 99

5 6

16B

SA

Lic

ens

e N

o: 1

1296

87

Em

ail:

desi

gn@

sobd

.net

© C

opyr

ight

res

erve

d in

par

t or

who

le. W

ritte

ndi

men

sion

s ta

ke p

refe

renc

e.C

ontr

acto

r to

ver

ify d

imen

sion

s.N

otify

des

igne

rs o

f dis

crep

anci

es.

Fai

lure

to d

o so

sha

ll vo

idth

e de

sign

ers

resp

onsi

bilit

ies.

THIS DESIGN IS THE EXCLUSIVE PROPERTY OF STUART OSMAN BUILDING DESIGNSN.B ALL WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED SIZES

BE WARNED: SUBSTITUTION OF ANY STRUCTURAL MEMBERS, AND OR ANY VARIATION TO ANY PART OF THE DESIGN WILL VOID ANYRESPONSIBILITIES OF STUART OSMAN BUILDING DESIGNS FOR THE STRUCTURAL INTEGRITY AND PERFORMANCE OF THE BUILDING

CLI

EN

T

PR

OJE

CT

JOB

NU

MB

ER

BU

ILD

ER

DR

AW

N B

YC

HE

CK

ED

BY

DE

SIG

N

DA

TE

SC

ALE

SA

ME

ND

ME

NT

S

SH

EE

T N

UM

BE

Rof

ME

MB

ER

OF C

HA

RT

ER

ED

ME

MB

ER

OF

ME

MB

ER

OF

quee

nsla

nd in

c.as

soci

atio

n of

build

ing

desi

gner

s

KIN

G

PR

OP

OS

ED

RE

NO

VA

TIO

N

65

AL

LAM

BI

AV

EB

RO

AD

BE

AC

H W

AT

ER

S

5082

JR A

09/0

5/2

013

SO

CU

STO

M

1:10

0 @

A3

21

22

D1

80

61

3E

23

07

13

F0

20

81

3G

13

08

13

H1

50

81

3I

02

09

13

J0

30

91

3K

19

09

13

L2

40

91

3M

18

10

13

N0

8111

3

2,70

02,

400

760

900

1,00

0

300

1,20

0

Slab & footings on compactedfill to engineers design

20 degree concrete tileroof to match existingPlasterboard lining to walls & ceilings,

villaboard lining to ALL wet areas

New 'vergola' roof tomanufacturers spec

New floor slabby engineer

Timber or aluminiumbatten screen recessedinto parapet wall

Stramit colorbond capping to topof all parapet walls, 1:100 fall backinto roof area, refer Parapet Details

Raised planter

HomeGuard termite protectionsystem to underside of slab,perimeter & penetrations, inaccordance with AS 3660.1

Rendered base to masonry column

Concrete drivewaygraded to suit

Upstand wall

New patio slab tomatch existing

Sus. Slab by engineer

SECTION 1:100

9C

LOUNGEPATIO ENTRY

MASTER BEDVOID

WIR

FL

FLCL

CL

FL

FLCL

CLBINDERS @ 3000 Ctrs.

to matchexisting

DECK

PORCH

POOLTo pool builders spec

Canal

20 degree roof trusses @ 600 ctrsas per truss manufacturers specification's

Page 22: 22 SECTION D Layout - The Web Console · 2015. 6. 10. · all pool fencing shall be min. 1200mm high and inaccordance with as 1926.1 proposed renovation for jr 090513 b roof deck

Pho

ne

(07)

55

203

022

Fax

(07

) 55

203

033

PO

Box

284

5 B

urle

igh

Hea

ds D

C Q

ld 4

220

Add

ress

: 2/7

1 T

ow

nsh

ip D

rive

, Wes

t Bur

leig

h, Q

LD 4

219

AB

N 7

3 09

7 99

5 6

16B

SA

Lic

ens

e N

o: 1

1296

87

Em

ail:

desi

gn@

sobd

.net

© C

opyr

ight

res

erve

d in

par

t or

who

le. W

ritte

ndi

men

sion

s ta

ke p

refe

renc

e.C

ontr

acto

r to

ver

ify d

imen

sion

s.N

otify

des

igne

rs o

f dis

crep

anci

es.

Fai

lure

to d

o so

sha

ll vo

idth

e de

sign

ers

resp

onsi

bilit

ies.

THIS DESIGN IS THE EXCLUSIVE PROPERTY OF STUART OSMAN BUILDING DESIGNSN.B ALL WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED SIZES

BE WARNED: SUBSTITUTION OF ANY STRUCTURAL MEMBERS, AND OR ANY VARIATION TO ANY PART OF THE DESIGN WILL VOID ANYRESPONSIBILITIES OF STUART OSMAN BUILDING DESIGNS FOR THE STRUCTURAL INTEGRITY AND PERFORMANCE OF THE BUILDING

CLI

EN

T

PR

OJE

CT

JOB

NU

MB

ER

BU

ILD

ER

DR

AW

N B

YC

HE

CK

ED

BY

DE

SIG

N

DA

TE

SC

ALE

SA

ME

ND

ME

NT

S

SH

EE

T N

UM

BE

Rof

ME

MB

ER

OF C

HA

RT

ER

ED

ME

MB

ER

OF

ME

MB

ER

OF

quee

nsla

nd in

c.as

soci

atio

n of

build

ing

desi

gner

s

KIN

G

PR

OP

OS

ED

RE

NO

VA

TIO

N

65

AL

LAM

BI

AV

EB

RO

AD

BE

AC

H W

AT

ER

S

5082

JR A

09/0

5/2

013

SO

CU

STO

M

1:10

0 @

A3

22

22

D1

80

61

3E

23

07

13

F0

20

81

3G

13

08

13

H1

50

81

3I

02

09

13

J0

30

91

3K

19

09

13

L2

40

91

3M

18

10

13

N0

8111

3

Tiered spill edge waterfeature to pool builders spec

1200mm high pool fence,to AS 1926.1

FL

FLCL

SPA

POOLTo pool builders spec

Canal

2,70

02,

700

200

Slab & footings on compactedfill to engineers design

Timber or aluminium batten screenwith perspex panel fixed to inside

20 degree concrete tileroof to match existing

Beam by engineerin bulkhead

Low level sliding dooraccess into roof space Line of existing roof

Sus. Slab by engineer

Plasterboard lining to walls & ceilings,villaboard lining to ALL wet areas

HomeGuard termite protectionsystem to underside of slab,perimeter & penetrations, inaccordance with AS 3660.1

SECTION 1:100

9D

FL

FLCL

CL

TILED ROOF DECKGYM

GAMES GARAGEBED 2BED 3FAMILY ROBE

SPA

ROBE

inc 40fasciaBINDERS @ 3000 Ctrs.

BINDERS @ 3000 Ctrs.

20 degree roof trusses @ 600 ctrsas per truss manufacturers specification's