copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv...

30
Property address Client's name Date of inspection 04 January 2013 Draft

Transcript of copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv...

Page 1: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

Property address

Client's name

Date of inspection 04 January 2013

D r a f t

Page 2: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

RICS is the world's leading qualification when it comes to professional standards in land, property and construction.

In a world where more and more people, governments, banks and commercial organisations demand greater certainty of professional standards and ethics, attaining RICS status is the recognised mark of property professionalism.

Over 100,000 property professionals working in the major established and emerging economies of the world have already recognised the importance of securing RICS status by becoming members.

RICS is an independent professional body originally established in the UK by Royal Charter. Since 1868, RICS has been committed to setting and upholding the highest standards of excellence and integrity ­ providing impartial, authoritative advice on key issues affecting businesses and society.

The RICS HomeBuyer Report is reproduced with the permission of the Royal Institution of Chartered Surveyors who owns the copyright.

A Introduction to the report B About the inspection C Overall opinion and summary of the condition ratings D About the property E Outside the property F Inside the property G Services H Grounds (including shared areas for flats) I Issues for your legal advisers J Risks K Valuation L Surveyor's declaration What to do now Description of the RICS HomeBuyer Service Typical house diagram

© 2010 RICS

2

D r a f t

Page 3: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

This HomeBuyer Report is produced by an RICS surveyor who has written this report for you to use. If you decide not to act on the advice in this report, you do this at your own risk.

The HomeBuyer Report aims to help you:

make a reasoned and informed decision on whether to go ahead with buying the property;

make an informed decision on what is a reasonable price to pay for the property;

take account of any repairs or replacements the property needs; and

consider what further advice you should take before committing to purchase the property.

Any extra services we provide that are not covered by the terms and conditions of this report must be covered by a separate contract.

If you want to complain about the service, please refer to the complaints handling procedure in the 'Description of the RICS HomeBuyer Service' at the back of this report.

3

Property address

D r a f t

Page 4: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

Surveyor's name

Surveyor's RICS number

Company name Copeland Yussuf LLP

Date of the inspection 04 January 2013 Report reference number

Related party disclosure None

Full addressand postcodeof the property

Weather conditionswhen the inspection

took place

Dry and bright with a temperature of circa 10oC.

The status of theproperty when the

inspection took place

The property was occupied and fully furnished with floor coverings throughout.

4

Property address

D r a f t

Page 5: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

We inspect the inside and outside of the main building and all permanent outbuildings, but we do not force or open up the fabric. We also inspect the parts of the electricity, gas/oil, water, heating and drainage services that can be seen, but we do not test them.

To help describe the condition of the home, we give condition ratings to the main parts (the 'elements') of the building, garage and some parts outside. Some elements can be made up of several different parts.

In the element boxes in parts E, F, G and H, we describe the part that has the worst condition rating first and then briefly outline the condition of the other parts. The condition ratings are described as follows.

The report covers matters that, in the surveyor's opinion, need to be dealt with or may affect the value of the property.

Important note: We carry out only a visual inspection. This means that we do not take up carpets, floor coverings or floorboards, move furniture or remove the contents of cupboards. Also, we do not remove secured panels or undo electrical fittings.

We inspect roofs, chimneys and other surfaces on the outside of the building from ground level and, if necessary, from neighbouring public property and with the help of binoculars.

We inspect the roof structure from inside the roof space if there is access (although we do not move or lift insulation material, stored goods or other contents). We examine floor surfaces and under­floor spaces so far as there is safe access to these (although we do not move or lift furniture, floor coverings or other contents). We are not able to assess the condition of the inside of any chimney, boiler or other flues.

We note in our report if we are not able to check any parts of the property that the inspection would normally cover. If we are concerned about these parts, the report will tell you about any further investigations that are needed.

Defects that are serious and/or need to be repaired, replaced or investigated urgently.

Defects that need repairing or replacing but are not considered to be either serious or urgent. The property must be maintained in the normal way.

No repair is currently needed. The property must be maintained in the normal way.

Not inspected (see 'Important note' below).

We do not report on the cost of any work to put right defects or make recommendations on how these repairs should be carried out. Some maintenance and repairs we suggest may be expensive.

Please read the 'Description of the RICS HomeBuyer Report Service' (at the back of this report) for details of what is, and isnot, inspected.

5

Property address

D r a f t

Page 6: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

This section provides our overall opinion of the property, and summarises the condition ratings of the different elements of the property.

If an element is made up of a number of different parts (for example, a pitched roof to the main building and a flat roof to an extension), only the part in the worst condition is shown here.

Our overall opinion of the property

To make sure you get a balanced impression of the property, we strongly recommend that you read all sections of the report, in particular the 'What to do now' section.

This property is considered to be a reasonable proposition for purchase and is felt to generally be in a fair condition, however we have noted various items, as contained within our report, which we would recommend require further investigation, renewal and/or making good.

Section of the report Element number Element name

Outside the Property E3 Rainwater pipes and gutters

Inside the property F7 Woodwork

Services G2 Gas

Section of the report Element number Element name

Outside the property E2 Roof coverings

Outside the property E4 Main walls

Outside the property E5 Windows

Outside the property E6 Outside doors

Outside the property E8 Other joinery and finishes

Inside the property F3 Walls and partitions

Inside the property F5 Fireplaces, chimney breasts and flues

Inside the property F6 Built­in fittings

Inside the property F8 Bathroom fittings

6

Property address

D r a f t

Page 7: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

Inside the property F9 Other

Services G1 Electricity

Grounds H2 Other

Section of the report Element number Element name

Outside the property E1 Chimney Stacks

Outside the property E7 Conservatory and porches

Inside the property F1 Roof structure

Inside the property F2 Ceilings

Inside the property F4 Floor

Services G3 Water

Services G4 Heating

Services G5 Water heating

Services G6 Drainage

7

Property address

D r a f t

Page 8: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

Accommodation

Construction

Type of property Four bedroom terrace house

Approximate year the property was built Circa 1914

Approximate year the property was extended Circa 2009

Approximate year the property was converted N/A

Information relevant to flats and maisonettes N/A

Floor Living rooms

Bed­ rooms

Bath or shower

Separate toilet

Kitchen Utility room

Conser­ vatory

Other Name of other

Lower ground

Ground 1 1 1

First 2 1

Second 2

Third

Other

Roof space

The main roof to the property is a duo pitched, hipped roof covered with ‘Redland 49’ concrete interlocking tiles. The roof incorporates a gable to both the front and rear elevation. The property also has a mono­pitched roof to the rear elevation along with two flat roof areas. The main external walls to the original structure are of solid masonry construction with a rendered finish, which have been painted. The extension (areas constructed circa 2009) is formed of masonry cavity construction. Floors are of suspended timber construction with the exception of the ground floor extension (kitchen area) which is ground bearing solid construction. Windows throughout the property are side and top hung uPVC double glazed units. There are

8

Property address

D r a f t

Page 9: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

two Velux roof­lights serving the kitchen along with a further ‘domed’ roof light.

9

Property address

D r a f t

Page 10: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

Energy

We have not prepared the Energy Performance Certificate (EPC). If we have seen the EPC, then we will present the ratings here. We have not checked these ratings and so cannot comment on their accuracy.

We are advised that the property's current energy performance, as recorded in the EPC, is:

Mains services

The marked boxes show that the mains services are present.

Central heating

Other services or energy sources (including feed­in tariffs)

Grounds

Location

Facilities

Energy­efficiency rating Rating 75 (Band C)

Environmentalimpact rating

We have not been provided a copy of this section of the EPC from the Vendor and therefore are unable to advise.

Gas Electricity Water Drainage

Gas Electric Solid fuel Oil None

The property has capabilities for BT installations.

The property is provided with paved areas to the front, a rear garden and a shed. There is also off street parking to the rear (See Section H).

The property is located within a residential area, with the immediately adjacent properties being of a similar age and construction. The property is located near to ‘busy’ roads in the form of Old Bexley Lane.

The property is within reasonable distance of the usual amenities, with shops and restaurants located in Somewhere Village approximately a 3 minute drive away.

10

Property address

D r a f t

Page 11: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

Local environment

Searches on the Local Authority website advise that the area is located within the Borough's Smoke Control Zone (See I1) and sits above a Groundwater Aquifer. A groundwater aquifer is an underground layer that holds water within soil, porous rock, or similar material. Further searches should be made by your Solicitor along with notifying your appropriate insurers.

11

Property address

D r a f t

Page 12: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

Limitations to inspection

We have visually inspected the readily accessible external elements of the property from ground level only.

E1Chimney stacks

There are two chimney stacks to the property both of masonry construction. The main stack serving this property (adjoining No 50 Somewhere Road) has had its clay pots removed at some point in the past. It is not possible to confirm that the pots have been correctly removed and the flues capped off and ventilated to prevent moisture penetration and condensation. Both chimney stacks appear to be in a structurally sound condition with no evidence of any unacceptable thermal cracking or deviation from vertical. To the brickwork, some areas of minor frost and sulphate attack are visible, although this is not considered urgent. Stepped lead flashings are provided at the junction of the main chimney stack and the roof coverings. From inspection from ground level with binoculars the flashings were noted to be in place and in satisfactory condition, however areas are heavily stained and are starting to lift although no evidence of rainwater penetration is currently noted. The junction of the rear stack and the coverings was not visible from ground level. A television aerial and Sky dish have been fixed to the main stack. Chimney stacks were not designed to support television aerials and the fitment of aerials can, in extreme cases, exert undue pressure/strain on to the structure. It is therefore important that the fixing brackets to the aerial are well restrained as any loose brackets could cause damage to the chimney stack and if the aerial were to fall, damage to the adjacent structure.

E2Roof coverings

The main roof to the property is a duo pitched, hipped roof covered with Redland 49 style concrete interlocking tiles. The main roof slopes over the property were noted to be acceptably even and free from any undue distortion, deflection or distress. This suggests that the roof framework is dealing adequately with the imposed load of the roof coverings. Where visible, the coverings to the main pitched roof were considered to be in a sound condition, consistent with their age (Condition Rating 1). We would however like to highlight that there were areas of the main roof that were not visible. The mono­pitched roof to the single storey rear extension is covered with Redland 49 tiles. Although there is no evidence of water penetration at present, we would like to highlight that the use of this particular tile on such a low gradient is not considered appropriate due to the natural camber of the tile. We would expect a flat tile to be used to prevent the risk of potential water ingress and should be factored in as an area which may require attention in the future (Condition Rating 1). To the mono­pitched roof to the rear extension, at the abutment with the right hand side flank wall, we noted the mortar fillet detail to the eaves to be defective with sections which have become loose and fallen. This should be re­detailed to prevent potential water ingress/insect infestation (Condition Rating 2).

12

Property address

D r a f t

Page 13: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

To the rear extension there are two separate flat roof areas both of which are covered with felt and likely to have been covered circa 2009 during the construction of the extension. We have various concerns with the original workmanship and condition of both areas particularly considering their age. Although there was no evidence internally of water ingress currently taking place, we are of the opinion that the detail of various sections is extremely poor. For example, the lead flashing details abutting the parapets and main structure encompassing both areas, have been ‘stuck on’ rather than being wedged and pointed in to adjacent wall surfaces as to be expected by a competent professional. This current ‘stuck on’ arrangement is already coming away from the superstructure and therefore we are of the opinion that the current detail will fail in the future potentially allowing a large amount of rainwater into the building. The domed roof light to the kitchen has been provided with ‘tape’ to prevent rainwater ingress rather than a proprietary finish, which again is poor workmanship. To the area of flat roof immediately adjacent to the domed roof light, we noted a section of roof felt which appeared to be newer than that immediately adjacent; perhaps indicating an area has failed (since 2009) which warranted remedial work. Should you proceed with the purchase of the property, we would recommend factoring in a sum of money to re­detail both flat roofs along with providing adequate lead flashings which will be required in the future to prevent rainwater ingress. (Condition Rating 2).

E3Rainwater pipes

and gutters

All roofs to the property are provided with black uPVC half round and round section gutters and downpipes respectively. Both the front and rear elevations are served by a single downpipe which are both shared with No 50 Baldwyns Road. There does not appear to be any issues of concern to the front elevation at present. To the rear elevation, there is the same arrangement i.e. both No’s 48 and 50 Somewhere Road share a single downpipe to take both roofs’ rainwater, however the downpipe accepting both properties’ waste currently discharges the rainwater onto the extension roof of No 50. It is however evident that this is a recent arrangement, as it can be seen that rainwater has discharged against the external walls for a period of time resulting in heavy staining. Should you proceed with the purchase of this property, we would recommend agreeing arrangement details of this downpipe with the owner of No 50 (Condition Rating 3). To the rear extension, the gutter taking the waste from the bathroom flat roof was noted to be too short. This has resulted in rainwater discharging down the render and heavy staining. This gutter should be re­detailed in order to prevent further staining (Condition Rating 2).

E4Main walls

Main external walls to the original structure are of solid masonry construction with a render finish, which has been painted. The extensions are formed of cavity masonry construction. At the time of inspection there was no significant evidence of recent or progressive movement to warrant further investigation or essential works of repair. All areas to the original structure were generally noted to be in a sound condition with the exception to a few spalled bricks due to frost and sulphate attack however are not considered to be of major concern at present. The render to the original structure was generally noted to be in satisfactory condition free from any evidence of widespread impact damage, spalling or deterioration (Condition Rating

13

Property address

D r a f t

Page 14: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

1). The render to the extension was noted to be heavily stained in areas due to defective rainwater goods. This has been discussed further under Section E3. With consideration to the age of extensions, we would anticipate that insulation has been provided in between the cavities, however we are unable to confirm this without undertaking an obtrusive inspection. Note – the flank wall of the extension has not been rendered and has been left as bare blockwork. Internally, to the internal face of external walls, random probes with a recently calibrated Protimeter (moisture meter) were taken at regular intervals throughout the property, furniture and floor coverings permitting. We obtained a positive reading to the external wall at the half floor landing leading to the second floor (immediately beneath the window). Although access was not possible to verify the reason, we would anticipate there to be a small section of defective render warranting repair (Condition Rating 2).

E5Windows

Windows throughout the property are a mixture of side hung and top hung uPVC double glazed units, however the window to the second floor half landing is a fixed panel. There are also two Velux rooflights and a single domed fixed roof light serving the kitchen. At the time of the inspection, window operations were generally found to be in working condition and no evidence of failure to double glazing seals was noted. However, it was noted that a number of the windows were stiff to operate and require easing and adjusting, specifically the bathroom window which side hung casement requires easing and the top hung casement which requires a handle which is currently not provided. With the exception of these defective items, the windows were checked and found to generally be in good working order.

E6Outside doors

(including patio doors)

The property is provided with a stained timber front entrance door a set of double glazed uPVC design French doors to the rear. At the time of inspection the front door was found to be in good working order free from any significant defects (Condition Rating 1). The French doors to the rear of the property were noted to have a gap at the base even when closed. The frame of the French doors was noted not to be securely fastened to the superstructure as one would expect. The absence of flush closing doors may be a defect that was not picked up at the time of installation along with the weak fixing of the frame however should be brought to your attention as will compromise the security and thermal properties of the building (Condition Rating 2).

E7Conservatoryand porches

A covered entrance is provided to front of the property which is covered in painted clay tiles. There are no defects of serious concern at present.

14

Property address

D r a f t

Page 15: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

E8Other joineryand finishes

The property is provided with timber fascia and barge boards to the main building which were found to be in sound condition. All these painted finishes were considered to be in fair condition, subject to ongoing maintenance. (Condition Rating 1). The extension is provided with white coloured PVCu fascia and soffit boards. Various areas were noted to be incomplete warranting attention as is aesthetically poor and to prevent potential insect infestation (Condition Rating 2).

E9Other

N/A

15

Property address

D r a f t

Page 16: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

Limitations to inspection

The inspection was limited due to the presence of various fitted, fixed and applied floor coverings, usual fixtures and fittings and heavy items of furniture together with some storage within built­in cupboard spaces.

F1Roof structure

Inspection of the roof void was via the hatch on the second floor landing. There is no permanent lighting nor ladder provided. The main roof is assumed to be constructed using sawn cut timber rafters and purlins. Timber boarding is also provided in between the rafters and the battens. As noted in Section E2 the main roof slopes over the property were noted to be acceptably even and free from any undue distortion, deflection or distress. This suggests that the roof framework is dealing adequately with the imposed load of the roof coverings. There were no defects of concern at present.

F2Ceilings

Ceilings are anticipated to be a plasterboard throughout the property, all of which have a painted finish. All ceilings appeared to be in good condition, showing only the signs of fair wear and tear. There is however an access panel to the shower waste to the kitchen ceiling which is aesthetically poor.

F3Walls and partitions

The main walls internally are a mixture of solid and lightweight construction which are generally painted, with the exception of the bathroom where the walls are tiled to full height. The detail immediately adjacent to the steel support of the first floor front bedroom/rear bedroom partition visible within the lounge was noted to be unfinished and aesthetically poor (Condition Rating 2). Generally however all internal walls and partitions appeared to be in sound condition, showing only the signs of fair wear and tear.

F4Floor

Floors are of suspended timber construction with the exception of the ground floor extension (kitchen) which is of solid construction. Floors have been applied with various finishes including: laminate to all areas of the ground floor, porcelain tiles to the first floor bathroom and carpet to all other areas. There were some creaking floor boards noted, but these were not felt to be of any undue concern. The floors generally appear to be structurally sound underfoot, and where visible, the floor finishes are in a good condition. (Condition Rating 1). As a note, sub­floor ventilation to the ground floor is provided via air bricks to the front

16

Property address

D r a f t

Page 17: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

elevation only. The provision of sub­floor cross ventilation is important to prevent the development of condensation within the floor timbers. The absence of sub­floor ventilation can lead to the development of timber defects and in particular wet rot and dry rot which in the extreme can cause extensive damage to the property. The property would have been provided with air bricks to the rear elevation also; however these have been removed and blocked up as part of the construction of the extension.

F5Fireplaces, chimneybreasts and flues

There is a balanced flue serving the boiler, located within the kitchen room which exits through the rear elevation. Externally, we can advise that the flue outlet was noted to be clear and free from obstructions, although we would refer to Section G2 of this report for further guidance on gas installations. Internally the boiler flue is unfinished and requires a cowl fitted (Condition Rating 2). There are two chimney breasts following the party wall located which terminate within the second floor bedrooms. The remainder of these breasts would have followed into the first floor bedrooms and to the ground floor however these have been removed at some point in the past. Without undertaking obtrusive inspections, we are unable to confirm whether the chimney stacks are provided with adequate support. As a note, the redundant chimney breasts should be ventilated to mitigate the risk of condensation build up. The chimney breast to the shared, rear chimney runs externally with no apparent defects noted.

F6Built­in fittings (built­in

kitchen and other fittings,not including appliances)

There is a modern kitchen provided with a built in oven, hob and extract above, dishwasher and washing machine. We have been informed that the vendor will be removing the fridge/freezer, however we understand that all other appliances are to remain. Generally all kitchen units were felt to be in a fair condition, showing only signs of fair wear and tear. We did however note that the sink drainer is damaged warranting a minor repair.

F7Woodwork (for

example, staircaseand joinery)

There is a mixture of internal joinery throughout the property including, 6 panelled painted doors, painted skirtings, frames, architraves and window cills. Skirtings and architraves show signs of wear and tear consistent with age and normal use. Simple repairs may be required in conjunction with the next redecoration. The main staircases between the ground and second floor levels are of timber construction and are generally firm to tread. The balustrading/handrails are also felt to be in a satisfactory condition. We did however note three protruding nails to the inner stair case string leading from the ground floor to first floor. These should be removed to prevent potential serious injury (Condition Rating 3). With the exception of the above noted and the general easing and adjusting of doors, any repairs required are regarded as aesthetic only (Condition Rating 1).

17

Property address

D r a f t

Page 18: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

F8Bathroom fittings

The main bathroom at first floor level consists of an uPVC bath, separate uPVC shower tray and screen, porcelain wash hand basin and a porcelain WC. The WC at ground floor level also has a porcelain WC and wash hand basin. All elements are considered to be in a fair condition, however tiling details to certain areas within the first floor bathroom were considered to be poor and unfinished. For example, the floor tiling adjacent to the WC was unfinished as was the tiling detail immediately adjacent to the bath. (Condition Rating 2). The bath has a Jacuzzi feature, however this was not tested and therefore cannot be confirmed as operational.

F9Other

Various speakers are mounted within the ceiling to the ground floor. We have been informed by the vendor that cable wiring is provided which leads back to an area within the under stairs cupboard should you wish to connect a sound source. We also noted that the bathroom extract fan (external side) does not have a cover. This requires rectification to prevent water ingress and insect infestation/birds nesting etc (Condition Rating 2).

18

Property address

D r a f t

Page 19: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

Services are generally hidden within the construction of the property. This means that we can only inspect the visible parts of the available services, and we do not carry out specialist tests. The visual inspection cannot assess the services to make sure they work efficiently and safely, and meet modern standards.

Limitations to inspection

None. The property was inspected in accordance with the agreed terms and conditions.

G1Electricity

Safety warning: The Electrical Safety Council recommends that you should get a registered electrician to check the property and its electrical fittings at least every ten years, or on change of occupancy. All electrical installation work undertaken after 1 January 2005 should have appropriate certification. For more advice contact the Electrical Safety Council.

The electrical service intake, meter and main distribution board are all situated in the cupboard under the stairs in the lounge. There are two distribution boards provided with MCBs (Miniature Circuit Breakers) however the second (newer) unit is also provided with an RCCB (Residual Current Circuit Breaker). No tests were carried out although at the time of inspection the electrical installation was noted to be operational. The electrical installation generally appears to be in a fair condition, although some areas are unfinished, for example the light fitting to the first floor has been partially removed. We also noted an electrical double socket plate and back box within the kitchen to be unfinished and extremely loose. Various bulbs throughout the property were also not in operation. We are unable to confirm whether bulbs are blown or whether these are defective fittings (Condition Rating 2). We have seen sight of the 'NICEIC' certificate from the vendor however the level of rewiring on the certificate is unspecified. We would suggest as the Institute of Electrical Engineers recommends that electrical wiring installations should be tested every five years to ensure ongoing safe working compliance. Whilst the majority of wiring and fittings do appear to be of modern specification we did note areas that are unlikely to have been included as part of the rewire. It would therefore be prudent for the system to be tested by a competent electrician, preferably one registered with the NICEIC, any upgrading work required undertaken and a test certificate provided upon completion confirming that the installation is in safe working compliance with the current requirements of the Institute of Electrical Engineers.

G2Gas/oil

Safety warning: All gas and oil appliances and equipment should regularly be inspected, tested, maintained and serviced by a registered 'competent person' and in line with the manufacturer's instructions. This is important to make sure that the equipment is working correctly, to limit the risk of fire and carbon monoxide poisoning and to prevent carbon dioxide and other greenhouse gases from leaking into the air. For more advice contact the Gas Safe Register for gas installations, and OFTEC for oil installations.

The gas meter is located externally to the front in a lockable proprietary unit and serves the boiler located in the kitchen. No test of the gas installation has been made, however there was a noticeable smell of gas when in close proximity to the gas meter at the time of our inspection. The gas meter was

19

Property address

D r a f t

Page 20: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

also heavily corroded. We advised the vendor that the smell of gas should be treated as an urgent issue. We would therefore recommend that you seek a 'Gas Safe' certification from the vendor which will advise of the latest condition of the gas installations (Condition Rating 3).

G3Water

The cold water plumbing where visible was in copper pipework and all appeared to be in sound condition.

G4Heating

The property is provided with a full wet central heating system served via a Vaillant EcoTec Pro 28 combination boiler located in the kitchen. A mixture of single, double finned radiators and towel rail to the bathroom are provided throughout the property. At the time of the inspection, the heating was operational.

G5Water heating

Water heating is provided via the Vaillant combination boiler. At the time of the inspection, the water heating was operational.

G6Drainage

The external plumbing is a mixture of uPVC wastes which all appear to be in a reasonable condition. There a single inspection chamber noted adjacent to the rear French doors. There was no evidence to suggest any problems with the infrastructure. Various open gullies were also noted which at the time of the inspection showed no blockage, although it is recommended that they be cleaned out regularly.

G7Common services

The property appears to be served with the provision of telephone connection. The property is also provided with an intruder alarm system, although these were not tested and therefore cannot be confirmed as operational. As noted earlier, a ‘Sky’ television dish is also present. Connection to these services would need to be arranged with the appropriate supplier.

20

Property address

D r a f t

Page 21: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

Limitations to inspection

None. The property was inspected in accordance with the agreed terms and conditions.

H1Garage

N/A

H2Other

To the rear garden there is a uPVC proprietary shed which is in a sound condition. The rear garden is encompassed by a mixture of timber post and panel fencing and a masonry wall. A section of fence has fallen and requires rectification (Condition Rating 2). The rear garden has areas of hardstanding and a path in the form of concrete brick paviours with the remainder laid to lawn (Condition Rating 1). The front garden is encompassed with masonry boundaries and has been laid with concrete pavings. All in a sound condition (Condition Rating 1).

H3General

N/A

21

Property address

D r a f t

Page 22: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

We do not act as 'the legal adviser' and will not comment on any legal documents. However, if during the inspection we identify issues that your legal advisers may need to investigate further, we may refer to these in the report (for example, check whether there is a warranty covering replacement windows).

I1Regulation

We have completed a brief search of the Local Authority website and can advise that an application relating to the property, in respect of the rear extension (Application Nos: ??/?????/FUL). The Local Authority website indicates that this application was granted with conditions. We would however recommend that clarification be sought from your solicitor accordingly, and that the associated conditions were suitably discharged. In addition, we would recommend that clarification be sought from your solicitor that the extensions is fully compliant with the Building Regulations and has the necessary Building Control approval. We would recommend that clarification be sought from your solicitor of the implications of being located within the Borough's Smoke Control Zone.

I2Guarantees

We would recommend that you seek the latest 'Gas Safe' certification from the vendor which will advise of the latest condition of the gas installations. We would also recommend that, where available, any guarantees in respect of the following be obtained from the vender where possible: ­ Replacement windows ­ Boiler ­ Kitchen appliances

I3Other matters

We have had sight of a neighbourhood environmental search from www.homecheck.co.uk, which is an online service. It is not a professional report but it is useful nonetheless in informing the direction of subsequent searches you may wish to carry out. We recommend that you and your legal adviser discuss the implications fully in conjunction with carrying out a full environmental search.

22

Property address

D r a f t

Page 23: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

This section summarises defects and issues that present a risk to the building or grounds, or a safety risk to people. These may have been reported and condition rated against more than one part of the property or may be of a more general nature, having existed for some time and which cannot be reasonably changed.

J1Risks to the building

As noted in I3, we recommend that your legal adviser carry out a full environmental search to establish any Risks to the Building.

J2Risks to the grounds

As noted in I3, we recommend that your legal adviser carry out a full environmental search to establish any Risks to the Grounds.

J3Risks to people

Although the manufacture of asbestos based building materials has now generally ceased, due to the age of the property, many products containing asbestos may be found within the property. These may include roofing felt, roof sheeting and slates, thermoplastic floor tiles, textured coatings, surface coatings, ceiling tiles, fireproof linings, roof edge verges and eaves soffits, soil and vent pipes, drainpipes, hoppers and waste pipes, gutters and downpipes, to name but a few. We did note areas of a textured finish within the second floor rear bedroom cupboard. This may indicate that areas of textured finish are present under the plaster finish to other ceiling areas. Problems arise when asbestos based materials need to be removed for reasons such as maintenance or repair, and when alterations are made to a building. Depending on the function of the material, certain notifications have to be given, followed by removal, by registered operatives, to disposal sites allocated specifically for this type of contaminated waste. Asbestos removal is expensive due to the substantial safety precautions which have to be taken. Further advice can be obtained from the Environmental Officer at the local council. The combination boiler is located in the kitchen. Carbon monoxide is colourless, odourless, and tasteless, but highly toxic to humans and animals when encountered. Carbon monoxide is produced from the partial oxidation of carbon containing compounds; it forms when there is not enough oxygen to produce carbon dioxide (CO2), such as when operating a an internal combustion engine in an enclosed space. It is recommended that consideration be given to the installation of a mains powered Carbon Monoxide detection to raise alarm where Carbon Monoxide levels increase. Further advice can be obtained from the Health and Safety Executive.

J4Other

There are no comments to make under this heading.

23

Property address

D r a f t

Page 24: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

(amount in words)

In my opinion the current reinstatement cost of the property (see note below) is:

(amount in words)

In arriving at my valuation, I made the following assumptions. With regard to the materials, construction, services, fixtures and fittings, and so on I have assumed that:

an inspection of those parts that I could not inspect would not identify significant defects or a cause to alter the valuation; no dangerous or damaging materials or building techniques have been used in the property; there is no contamination in or from the ground, and the ground has not been used as landfill; the property is connected to, and has the right to use, the mains services mentioned in the report; and the valuation does not take account of any furnishings, removable fittings or sales incentives.

With regard to legal matters I have assumed that:

the property is sold with 'vacant possession' (your legal advisers can give you more information on this term);

the condition of the property, or the purpose the property is or will be used for, does not break any laws; no particularly troublesome or unusual restrictions apply to the property, that the property is not affected by problems which would be revealed by the usual legal inquiries and that all necessary planning permissions and Building Regulations consents (including consents for alterations) have been obtained and complied with; and the property has the right to use the mains services on normal terms, and that the sewers, mains services and roads giving access to the property have been 'adopted' (that is, they are under local­authority, not private, control).

Any additional assumptions relating to the valuation

Your legal advisers, and other people who carry out property conveyancing, should be familiar with these assumptions and are responsible for checking those concerning legal matters.

My opinion of the Market Value shown here could be affected by the outcome of the enquiries by your legal advisers (section I) and/or any further investigations and quotations for repairs or replacements. The valuation assumes that your legal advisers will receive satisfactory replies to their enquiries about any assumptions in the report.

Other considerations affecting value

Note: You can find information about the assumptions I have made in calculating this reinstatement cost in the 'Description of the RICS HomeBuyer Service' provided. The reinstatement cost is the cost of rebuilding an average home of the type and style inspected to its existing standard using modern materials and techniques, and by acting in line with current Building Regulations and other legal requirements. This will help you decide on the amount of buildings

In my opinion the Market Value on 08 January 2013 as inspected was:

£

Tenure Freehold Area of property (sq m)

£

This opinion has been arrived at on the basis of the standard assumptions governing residential valuations. (These are outlined in Section K and under Market Value on The Description of the HomeBuyers Service).

None.

24

Property address

D r a f t

Page 25: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

insurance cover you will need for the property.

25

Property address

D r a f t

Page 26: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

"I confirm that I have inspected the property and prepared this report, and the Market Value given in the report."

For and on behalf of

RICS Disclaimers

Signature

Surveyor's RICS number Qualifications BSc (Hons) MCIOB MRICS

Company Copeland Yussuf LLP

Address The Garden Cottage, 217 Oakdene Road

Town Orpington County Kent

Postcode BR5 2AR Phone number 01689 872685

Website copelandyussuf.com Fax number 01689 872685

Email [email protected]

Property address

Client's name Date this reportwas produced

09 January 2013

1. This report has been prepared by a surveyor ('the Employee') on behalf of a firm or company of surveyors ('the Employer'). The statements and opinions expressed in this report are expressed on behalf of the Employer, whoaccepts full responsibility for these.

Without prejudice and separately to the above, the Employee will have no personal liability in respect of any statements and opinions contained in this report, which shall at all times remain the sole responsibility of the Employer to the exclusion of the Employee.

In the case of sole practitioners, the surveyor may sign the report in his or her own name unless the surveyor operates as a sole trader limited liability company.

To the extent that any part of this notification is a restriction of liability within the meaning of the Unfair Contract Terms Act 1977 it does not apply to death or personal injury resulting from negligence.

2. This document is issued in blank form by the Royal Institution of Chartered Surveyors (RICS) and is available only to parties who have signed a licence agreement with RICS.

RICS gives no representations or warranties, express or implied, and no responsibility or liability is accepted for the accuracy or completeness of the information inserted in the document or any other written or oral informationgiven to any interested party or its advisers. Any such liability is expressly disclaimed.

Please read the 'Description of the RICS HomeBuyer Report Service' (at the back of this report) for details of what is, and isnot, inspected.

26

Property address

D r a f t

Page 27: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

Getting quotations The cost of repairs may influence the amount you are prepared to pay for the property. Before you make a legal commitment to buy the property, you should get reports and quotations for all the repairs and further investigations the surveyor may have identified.

You should get at least two quotations from experienced contractors who are properly insured. You should also:

ask them for references from people they have worked for;

describe in writing exactly what you will want them to do; and

get the contractors to put the quotations in writing.

Some repairs will need contractors with specialist skills and who are members of regulated organisations (for example, electricians, gas engineers, plumbers and so on). Some work may also need you to get Building Regulations permission or planning permission from your local authority.

Further investigations If the surveyor is concerned about the condition of a hidden part of the building, could only see part of a defect or does not have the specialist knowledge to assess part of the property fully, the surveyor may have recommended that further investigations should be carried out to discover the true extent of the problem.

Who you should use for these further investigations You should ask an appropriately qualified person, though it is not possible to tell you which one. Specialists belonging to different types of organisations will be able to do this. For example, qualified electricians can belong to five different government­approved schemes. If you want further advice, please contact the surveyor.

What the further investigations will involve This will depend on the type of problem, but to do this properly, parts of the home may have to be disturbed and so you should discuss this matter with the current owner. In some cases, the cost of investigation may be high.

When to do the work The condition ratings help describe the urgency of the repair and replacement work. The following summary may help you decide when to do the work.

Condition rating 2 ­ repairs should be done soon. Exactly when will depend on the type of problem, but it usually does not have to be done right away. Many repairs could wait weeks or months, giving you time to organise suitable reports and quotations.

Condition rating 3 ­ repairs should be done as soon as possible. The speed of your response will depend on the nature of the problem. For example, repairs to a badly leaking roof or a dangerous gas boiler need to be carried out within a matter of hours, while other less important critical repairs could wait for a few days.

Warning Although repairs of elements with a condition rating 2 are not considered urgent, if they are not addressed they may develop into defects needing more serious repairs. Flat roofs and gutters are typical examples. These can quickly get worse without warning and result in serious leaks. As a result, you should regularly check elements with a condition rating 2 to make sure they are not getting worse.

27

Property address

D r a f t

Page 28: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

The service The RICS HomeBuyer Service includes:

an inspection of the property (see 'The inspection'); a report based on the inspection (see 'The report'); and a valuation, which is part of the report (see 'The valuation').

The surveyor who provides the RICS HomeBuyer Service aims to give you professional advice to help you to:

make an informed decision on whether to go ahead with buying the property; make an informed decision on what is a reasonable price to pay for the property; take account of any repairs or replacements the property needs; and consider what further advice you should take before committing to purchase the property.

The inspection The surveyor inspects the inside and outside of the main building and all permanent outbuildings, but does not force or open up the fabric. This means that the surveyor does not take up carpets, floor coverings or floorboards, move furniture, remove the contents of cupboards, roof spaces, etc., remove secured panels and/or hatches or undo electrical fittings. If necessary, the surveyor carries out parts of the inspection when standing at ground level from public property next door where accessible.

The surveyor may use equipment such as a damp­meter, binoculars and torch, and may use a ladder for flat roofs and for hatches no more than 3 metres above level ground (outside) or floor surfaces (inside) if it is safe to do so.

Services to the property

Services are generally hidden within the construction of the property. This means that only the visible parts of the available services can be inspected, and the surveyor does not carry out specialist tests. The visual inspection cannot assess the efficiency or safety of electrical, gas or other energy sources; plumbing, heating or drainage installations (or whether they meet current regulations); or the inside condition of any chimney, boiler or other flue.

Outside the property

The surveyor inspects the condition of boundary walls, fences, permanent outbuildings and areas in common (shared) use. To inspect these areas, the surveyor walks around the grounds and any neighbouring public property where access can be obtained.

Buildings with swimming pools and sports facilities are also treated as permanent outbuildings, but the surveyor does not report on the leisure facilities, such as the pool itself and its equipment, landscaping and other facilities (for example, tennis courts and temporary outbuildings).

Flats

When inspecting flats, the surveyor assesses the general condition of outside surfaces of the building, as well as its access areas (for example, shared hallways and staircases). The surveyor inspects roof spaces only if they are accessible from within the property. The surveyor does not inspect drains, lifts, fire alarms and security systems.

Dangerous materials, contamination and environmental issues

The surveyor does not make any enquiries about contamination or other environmental dangers. However, if the surveyor suspects a problem, he or she should recommend a further investigation. The surveyor may assume that no harmful or dangerous materials have been used in the construction, and does not

The surveyor does not carry out an asbestos inspection and does not act as an asbestos inspector when inspecting properties that may fall within the Control of Asbestos Regulations 2006. With flats, the surveyor assumes that there is a 'dutyholder' (as defined in the regulations), and that in place are an asbestos register and an effective management plan which does not present a significant risk to health or need any immediate payment. The surveyor does not consult the dutyholder.

The report The surveyor produces a report of the inspection for you to use, but cannot accept any liability if it is used by anyone else. If you decide not to act on the advice in the report, you do this at your own risk. The report focuses on matters that, in the surveyor's opinion, may affect the value of the property if they are not addressed.

The report is in a standard format and includes the following sections.

A Introduction to the report B About the inspection C Overall opinion and summary of the condition ratings D About the property E Outside the property F Inside the property G Services H Grounds (including shared areas for flats) I Issues for your legal advisers J Risks K Valuation L Surveyor's declaration What to do now Description of the RICS HomeBuyer Service Typical house diagram

Condition ratings

The surveyor gives condition ratings to the main parts (the 'elements') of the main building, garage and some outside elements. The condition ratings are described as follows.

Condition rating 3 ­ defects that are serious and/or need to be repaired, replaced or investigated urgently.

Condition rating 2 ­ defects that need repairing or replacing but are not considered to be either serious or urgent. The property must be maintained in the normal way.

Condition rating 1 ­ no repair is currently needed. The property must be maintained in the normal way.

NI ­ not inspected.

The surveyor notes in the report if it was not possible to check any parts of the property that the inspection would normally cover. If the surveyor is concerned about these parts, the report tells you about any further investigations that are needed.

The surveyor does not report on the cost of any work to put right defects or make recommendations on how these repairs should be carried out. However, there is general advice in the 'What to do now' section at the end of the report.

Energy

The surveyor has not prepared the Energy Performance Certificate (EPC) as part of the RICS HomeBuyer Service for the property. If the surveyor has seen the current EPC, he or she will present the energy­efficiency and environmental impact ratings in this report. The surveyor does not check the ratings and cannot comment on their accuracy.

Issues for legal advisers

The surveyor does not act as 'the legal adviser' and does not comment on any legal documents. If, during the inspection, the surveyor identifies issues that your legal advisers may need

28

have a duty to justify making this assumption. However, if the inspection shows that these materials have been used, the surveyor must report this and ask for further instructions.

to investigate further, the surveyor may refer to these in the report (for example, check whether there is a warranty covering replacement windows).

Continued...

D r a f t

Page 29: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

Risks

This section summarises defects and issues that present a risk to the building or grounds, or a safety risk to people. These may have been reported and condition rated against more than one part of the property or may be of a more general nature, having existed for some time and which cannot reasonably be changed.

If the property is leasehold, the surveyor gives you general advice and details of questions you should ask your legal advisers.

The valuation The surveyor gives an opinion on both the Market Value of the property and the reinstatement cost at the time of the inspection (see the 'Reinstatement cost' section).

Market Value

'Market Value' is the estimated amount for which a property should exchange, on the date of the valuation between a willing buyer and a willing seller, in an arm's length transaction after the property was properly marketed wherein the parties had each acted knowledgeably, prudently and without compulsion.

When deciding on the Market Value, the surveyor also makes the following assumptions.

The materials, construction, services, fixtures and fittings, and so on

The surveyor assumes that:

an inspection of those parts that have not yet been inspected would not identify significant defects or cause the surveyor to alter the valuation; no dangerous or damaging materials or building techniques have been used in the property; there is no contamination in or from the ground, and the ground has not been used as landfill; the property is connected to, and has the right to use, the mains services mentioned in the report; and the valuation does not take account of any furnishings, removable fittings and sales incentives of any description.

Legal matters

The surveyor assumes that:

the property is sold with 'vacant possession' (your legal advisers can give you more information on this term); the condition of the property, or the purpose that the property is or will be used for, does not break any laws; no particularly troublesome or unusual restrictions apply to the property, that the property is not affected by problems which would be revealed by the usual legal enquiries and that all necessary planning and Building Regulations permissions (including permission to make alterations) have been obtained and any works undertaken comply with such permissions; and the property has the right to use the mains services on normal terms, and that the sewers, mains services and roads giving access to the property have been 'adopted' (that is, they are under local­authority, not private, control).

The surveyor reports any more assumptions that have been made or found not to apply.

If the property is leasehold, the general advice referred to earlier explains what other assumptions the surveyor has made.

Reinstatement cost

Reinstatement cost is the cost of rebuilding an average home of the type and style inspected to its existing standard using modern materials and techniques and in line with current Building Regulations and other legal requirements.

This includes the cost of rebuilding any garage, boundary or retaining walls and permanent outbuildings, and clearing the site. It also includes professional fees, but does not include VAT (except on fees).

The reinstatement cost helps you decide on the amount of buildings insurance cover you will need for the property.

Standard terms of engagement

Complaints handling procedure The surveyor will have a complaints handling procedure and will give you a copy if you ask.

Note: These terms form part of the contract between you and the surveyor.

This report is for use in England, Wales, Northern Ireland, Channel Islands and Isle of Man.

1 The service ­ the surveyor provides the standard RICS HomeBuyer Service ('the service') described in the 'Description of the RICS HomeBuyer Service', unless you and the surveyor agree in writing before the inspection that the surveyor will provide extra services. Any extra service willrequire separate terms of engagement to be entered into with the surveyor. Examples of extra services include:

costing of repairs; schedules of works; supervision of works; re­inspection; detailed specific issue reports; and market valuation (after repairs).

2 The surveyor ­ the service is to be provided by an AssocRICS, MRICS or FRICS member of the Royal Institution of Chartered Surveyors, who has the skills, knowledge and experience to survey, value and report on theproperty.

3 Before the inspection ­ you tell the surveyor if there is already an agreed, or proposed, price for the property, and if you have any particular concerns (such as plans forextension) about the property.

4 Terms of payment ­ you agree to pay the surveyor's fee andany other charges agreed in writing.

5 Cancelling this contract ­ you are entitled to cancel this contract by giving notice to the surveyor's office at any time before the day of the inspection. The surveyor does not provide the service (and reports this to you as soon as possible) if, after arriving at the property, the surveyor decides that:

If you cancel this contract, the surveyor will refund any moneyyou have paid for the service, except for any reasonable expenses. If the surveyor cancels this contract, he or she will explain the reason to you.

(a) he or she lacks enough specialist knowledge of the method of construction used to build the property; or

(b) it would be in your best interests to have a building survey and a valuation, rather than the RICS HomeBuyerService.

6 Liability ­ the report is provided for your use, and the surveyor cannot accept responsibility if it used, or relied upon,by anyone else.

29

D r a f t

Page 30: copelandyussuf.com · 2016-06-30 · 7klv+rph%x\hu5hsruwlvsurgxfhge\dq5,&6vxuyh\ruzkrkdvzulwwhqwklv uhsruwiru\rxwrxvh ,i\rxghflghqrwwrdfwrqwkhdgylfhlqwklvuhsruw \rxgr wklvdw\rxurzqulvn

This diagram illustrates where you may find some of the building elements referred to in the report.

30

Property address

D r a f t