2 Local Buckling and Section Classification - 2011

download 2 Local Buckling and Section Classification - 2011

of 21

Transcript of 2 Local Buckling and Section Classification - 2011

  • 7/30/2019 2 Local Buckling and Section Classification - 2011

    1/21

    2012

    Liew

    1

    Local Buckling &

    Section Classification

    CE5509 RLiew

    2

    Introduction

    ClassesofCrossSections

    MaximumWidthtoThicknessRatiosforCompressionPartsInternalCompressionPartsOutstandCompressionPartsAngles&TubularSections

    EffectiveCrossSectionforClass4Sections

    Class3Web+Class1or2Flange

    Examples

    ExampleSC

    1(Section

    classification

    for

    combined

    bending

    and

    compression)

    ExampleSC2(EffectiveareaofaClass4compressionmember)ExampleSC3(SectionwithClass3webandClass1flanges)

    Outline

    CE5509 RLiew

  • 7/30/2019 2 Local Buckling and Section Classification - 2011

    2/21

    2012

    Liew

    3

    Steel members are generally composed of thin elements for structuralefficiency.

    The slender elements are prone to local instabilities under compressivestress, even before the yield strength is reached.

    The effects of local buckling are accounted for in EC3 by classifying thecross-section into Classes 1, 2, 3 or 4.

    Cross-section classification is made by comparing actual width-to-thickness ratios of the plate elements with a set of limiting values.

    The classification of the overall cross-section is taken as the leastfavourable of the constituent elements.

    IntroductionCE5509 RLiew

    Local BucklingWhen the section is not standard section but fabricatedfrom thin elements, the section element may bucklelocally before fy is reached due to slenderness

    4

    RLiew

  • 7/30/2019 2 Local Buckling and Section Classification - 2011

    3/21

    2012

    Liew

    Local Buckling and Section Classification

    Factors Influencing Local Buckling

    Boundary conditionsinternal elements or outstands

    Local Slenderness d/t internal element (eg. web) b/T outstand (eg. flange)

    Youngs modulus Yield strength Stress distribution Strain (deformation) requirement Residual stresses

    b

    t

    5

    Elements to be classified

    For a Hot finished RHScf= (b-2r - tw)/2 cw=h-2(tf+ r)

    Universal Beam

    cf= b-2(tw+r) cw=h-2(t + r)

    6

    RLiew

    cf

    hcw

    b

    tWeb

    Flange

    Outstand

    cf

    Internal element

    cw

  • 7/30/2019 2 Local Buckling and Section Classification - 2011

    4/21

    2012

    Liew

    RLiew

    7

    Classes of Cross-Sections

    Why classify ?

    Class 1

    Rotation, Moment

    Mpl

    Mel

    Rotational capacity

    Class 2

    Class 3

    Class 4

    MM

    Neutral

    axis

    Neutralaxis

    Bending stress distributions at maximum moment capacity

    Class 2

    fy

    Class 3

    fy

    Class 4

    fy

    Class 1

    fy

    8

    RLiew

  • 7/30/2019 2 Local Buckling and Section Classification - 2011

    5/21

    2012

    Liew

    9

    StrainStress

    fy

    Classes of Cross-Sections

    Class 1Cross sections with both plastic moment capacity and plastic hinge rotation

    capacity.M

    c,Rd

    = fy

    Wpl

    /M0

    Class 2Cross-sections with plastic moment capacity but limited plastic hinge

    rotation capacity.Mc,Rd= fyWpl /M0

    Class 3Cross-sections in which the stress in the extreme compression fibre canreach the yield strength, but only the elastic moment capacity can bedeveloped.

    Mc,Rd= fyWel /M0

    Class 4Cross-sections in which local buckling will occur before the attainment of

    yield stress.Mc,Rd= fyWeff/M0

    Class 1

    Rotation, Moment

    MplMel

    Rotational capacity

    Class 2

    Class 3

    Class 4

    RLiew

    10

    Maximum Width to Thickness Ratiosfor Compression Parts

    CE5509 RLiew

  • 7/30/2019 2 Local Buckling and Section Classification - 2011

    6/21

    2012

    Liew

    RLiew

    11

    Internal COMPRESSION Parts

    ClassPart subjectto bending

    Part subj ect tocompression

    Part subject to Stress distributionb end in g an d co mp res si on (c om pr es si on +v e)

    1

    2

    3

    Max Width-to-Thickness Ratios for Compression Parts

    Web

    InternalFlange

    EN 1993-1-1 (Table 5.2)

    12

    Consider the case ofI orH section subjected to compression and major axis bending, wherethe neutral axis lies within the web.

    +

    The ratio of the tensile stress to the compressive stress

    at the extreme fibers, , can be calculated as follows:

    The ratio of the compressed width to the total width

    of the element, , can be calculated as follows:

    +

    tf

    tw

    RLiew

  • 7/30/2019 2 Local Buckling and Section Classification - 2011

    7/21

    2012

    Liew

    13

    ClassPart subject to Stress distributioncompression (compression +ve)

    Part subject to bending and compression

    Tip in Stress distribution

    compression (compression +ve)

    Tip in Stress distribution

    tension (compression +ve)

    1

    2

    3

    Outstand COMPRESSION Parts

    Max Width-to-Thickness Ratios for Compression Parts

    OutstandFlange

    Determination ofBuckling Factork

    c

    + 12

    c

    + 12 -

    =2/1 1 0 -1 1 -3

    k

    0.43 0.57 0.85 0.57 - 0 .21+ 0.072

    c

    + 21

    c

    + 21

    -

    =2/1 1 1 0 0 0 -1 -1

    k

    0.43 0.578/(+ 0.34) 1.70 1.7 -5+ 17.12 23.8

    21 21

    EN 1993-1-1 (Table 5.2)

    EN 1993-1-5 (Table 4.2)

    RLiew

    14

    Class Section in compression

    1

    2

    3

    Angles(not in continuous contact with other components)

    Max Width-to-Thickness Ratios for Compression Parts

    Tubular Sections

    Class Section in bending and/or compression

    1

    2

    3

    EN 1993-1-1 (Table 5.2)

    RLiew

  • 7/30/2019 2 Local Buckling and Section Classification - 2011

    8/21

    2012

    Liew

    15

    Effective Cross-Sectionfor Class 4 Sections

    CE5509 RLiew

    16

    Effective Cross-Section for Class 4 SectionsEN 1993-1-5 Clause 4.4

    Stepsindeterminingthereductionfactorforplatebuckling

    Determine the stress distribution

    AdditionalrulesforelementsofIsectionandBoxGirder

    For flange elements, use the gross cross-sectional area to determine the stress distribution.

    For web elements, use the effective area of the compression flange and the gross area of the web todetermine the stress distribution.

    Determine stress ratio 2/1 and buckling factork

    This depends on whether it is internal or external compression element.

    The effective area Aeff should be determined assuming that the cross section is subjectonly to uniform axial compression.

    The effective section modulus Weff should be determined assuming the cross section is subjectonly to bending moment.For biaxial bending, effective se ction moduli should be determined about both main axes.

    whereAc and bc are respectively the area of the section and the width of the element in compression.

    CE5509 RLiew

  • 7/30/2019 2 Local Buckling and Section Classification - 2011

    9/21

    2012

    Liew

    17

    2

    1

    2

    1

    InternalCompressionElements

    1 0 1k 4.0 7.81 23.9

    Common values of

    OutstandCompressionElements

    1

    212

    2

    1

    2

    1

    1 0 1k 0.43 0.57 0.85

    Common values of

    Tipunderlarger compressivestress

    1 0 1k 0.43 1.70 23.8

    Common values of

    Tipundersmaller compressivestress

    k1 0 8.2/(1.05 + )

    0 1 7.81 6.29+ 9.782

    1 3 5.98(1 2)

    k1 3 0.57 0.21+ 0.072

    k1 0 0.578/(+ 0.34)

    0 1 1.7 5+ 17.12

    Stress ratio and buckling factork

    CE5509 RLiew

    18

    Calculatebw for websb for internal flange elements (except RHS)

    b 3t for flanges of RHS

    c for outstand flanges

    h for angles

    Calculate

    Internalcompressionelements

    Outstandcompressionelements

    CE5509 RLiew

  • 7/30/2019 2 Local Buckling and Section Classification - 2011

    10/21

    2012

    Liew

    19

    21

    2

    1

    InternalCompressionElements

    OutstandCompressionElements

    1

    2

    12 2

    1

    2

    1

    Tipunderlarger compressivestress Tipundersmaller compressivestress

    21

    Effective Width for Class 4 Elements

    CE5509 RLiew

    Cold formed steel sections

    These sections aremade from thin- steelsheets.

    They are prone tolocal buckling.

    Effective sectionproperties are needed.

    20

    SSEN 1993-1-3

  • 7/30/2019 2 Local Buckling and Section Classification - 2011

    11/21

    2012

    Liew

    21

    Class 3 Web + Class 1 or 2 Flange

    CE5509 RLiew

    CE5509 RLiew

    22

    Class 3 Web + Class 1 or 2 Flange

    EN 1993-1-1 (Cl 5.5.2(11) & Cl 6.2.2.4)

    Cross-sections with Class 3 webs and Class 1 or 2 flanges can be classified as

    effective Class 2 cross-sections with the compressed portion of the web being

    replaced by a part of 20tw adjacent to the compression flange (measured from the base

    of the root radius for rolled section and the base of the weld for welded section), with

    another part of 20tw adjacent to the plastic neutral axis of the effective cross-section.

    b

    20tw

    h

    tw

    20twCompression

    Tension

    Plastic neutral axis

    fy

    fy

    +

    Neglectedineffectivearea

    20tw

    20tw

    tw

    b

    40tw

  • 7/30/2019 2 Local Buckling and Section Classification - 2011

    12/21

    2012

    Liew

    8/14/2012

    23

    Implications for Design

    Class 1. Plastic mustbe used in plasticdesign, can sustain high strain. Can beusedwithoutrestriction in normaldesign

    Class 2 Compact can be used with theplastic modulus in bending

    Class3 Semi-compact when inbending the elastic modulus or aneffective plastic modulus mustbe used

    Class 4 Slender Effective sectionproperties must be used

    Section and Design Tables

    Steel building design:Design data,Publication P363, TheSteel Construction

    Institute and the

    British Constructional

    Steelwork Association

    UK, 2009.

    24

  • 7/30/2019 2 Local Buckling and Section Classification - 2011

    13/21

    2012

    Liew

    8/14/2012

    25

    Based on Steel buildingdesign: Design data

    n limit =NE,d/ Npl,Rd

    Class 2 limit

    Class 3 limit

    8/14/2012

    26

    General Guidancewhen using the Deign TablesSteel building design: Design data, Publication P-363, jointly published by

    The Steel Construction Institute and the British Constructional SteelworkAssociation UK, 2009 (IVLE).

    None of the universal beam and column sections ingrade S275 and S355 are class 4 under bending only.

    None of the universal columns can be class 4 underpure compression; but some universal beams andhollow sections can be class 4. Sections that can beclass 4 under pure compression are marked with * in

    the design tables. None of the UC or UB sections l isted in the design

    tables are slender due to the flange being class 4.Under combined axial compression and bending, thesection would be Class 2 or Class 3 up to given n =NEd/N pl,Rd limits.

  • 7/30/2019 2 Local Buckling and Section Classification - 2011

    14/21

    2012

    Liew

    8/14/2012

    27

    Summary of design procedure

    1 Select, from experience, a suitable sectionbased on the factored load effects

    2Determine the section classification

    3 If necessary calculate effective plasticmodulus for Class 3 (semi-compact) sections

    4 If necessary calculate effective sectionproperties for class 4(slender sections)

    5 Proceed with design procedures suitable for

    the section classification

    RLiew

    28

    Examples

    CE5509

  • 7/30/2019 2 Local Buckling and Section Classification - 2011

    15/21

    2012

    Liew

    RLiew

    29

    Design Strengthtw = 7.7mm, tf= 10.9mm.

    Maximum thickness = 10.9mm < 16mm (EN 10025-2)

    For S275 steel, fy = 275N/mm2

    Example SC-1: Section classification fo r combined bending and compression

    A member is to be designed to carry combined bending and axial load. In the presence of a

    major axis (y-y) bending moment and an axial compression of 300kN, determine the cross-

    section classification of a 406x178x54UB in grade S275 steel.

    CE5509

    RLiew

    30

    Section Classification

    First, classify the cross-section under the most severe loading condition of pure compression todetermine whether anything is to be gained by more precise calculations.

    Cross-section classification under pure compression

    Classification of Flange

    = (235 /fy)0.5 = 0.92

    Flange is Class 1.

    Classification of Web

    Web is Class 4.

    Under pure compression, the overall cross-section is therefore Class 4.Material efficiency are therefore to be gained by using a more precise approach.

    CE5509

  • 7/30/2019 2 Local Buckling and Section Classification - 2011

    16/21

    2012

    Liew

    RLiew

    31

    Cross-section classification under combined loading

    Flange classification remains the same as Class 1.

    Classification of Web

    Web is Class 2.

    Under combined loading, the overall cross-section is therefore Class 2.

    CE5509

    CE5509 RLiew

    32

    Page C-149n =300/1900=0.16

  • 7/30/2019 2 Local Buckling and Section Classification - 2011

    17/21

    2012

    Liew

    8/14/2012

    33

    Example 2

    S275 steel 457x152x52 UBGrade S275

    A) Subject to bending about

    its major axis

    B) Subject to 800kN axial load

    and bending about its major

    axis

    C) Subject to 1500kN axial

    load and bending about its

    major axis

    8/14/2012

    34

    Class 2 if n < 0.169 or

    NEd < 0.169 x 1830 = 309kN

    Class 3 if n < 0.586 or

    F < 0.586 x 1830 = 1073 kN

    Page C-147

    Based on Steel buildingdesign: Design data

  • 7/30/2019 2 Local Buckling and Section Classification - 2011

    18/21

    2012

    Liew

    8/14/2012

    35

    a) Pure bending about its major axis

    S275 steel 457x152x52 UB Grade S275

    A) Subject to bending about its major axis

    n = 0, therefore class 2

    B) Subject to 800kN axial load and bending about its major axis

    n = 800/1830 = 0.437 > 0.169 class 3

    C) Subject to 1500kN axial load and bending about its major axis

    n = 1500/1830 = 0.82>0.586 class 4

    Npl,Rd =fyAeffMel,Rd = fyWeff

    Npl,Rd =fyA

    Mpl,Rd = fyWpl,Rd

    Npl,Rd =fyA

    Mel,Rd = fyWel,Rd

    8/14/2012

    36

    Summary

    For optimum design of welded section, thedesigner has the following choices

    1. Eliminate local buckling by ensuringwidth-to-thickness ratio is sufficientlysmall

    2. If higher width-to-thickness is used, usestiffeners to reduce plate width

    3. Determine section capacity allowing forlocal buckling

  • 7/30/2019 2 Local Buckling and Section Classification - 2011

    19/21

    2012

    Liew

    8/14/2012

    37

    Q1 What happen when the limiting plateslenderness ratios are exceeded?

    Cross section strength cannot be fully developed.

    i.e., cross section strength is governed by local bucklinginstead of yielding.

    Q2 How can we prevent local buckling of a plate

    component?

    Ensure that b/t ratio is compact. Provide plate stiffener

    Questions

    8/14/2012

    38

    Q3 What effect does a slender andunstiffened element have on the strengthof compression member as opposed tothat of a non-slender element?

    Slender element reduces the compression

    resistance of the compression memberbecause of local buckling effect

  • 7/30/2019 2 Local Buckling and Section Classification - 2011

    20/21

    2012

    Liew

    8/14/2012

    39

    8/14/2012

    40

    Quiz

    Which of the followings are considered to bean internal elements?

    1. leg of an angle

    2. flange of a channel

    3. Web of a I section

    4. Wall of HSS

  • 7/30/2019 2 Local Buckling and Section Classification - 2011

    21/21

    2012

    8/14/2012

    41

    Q5 Determine the section classification ofthe following sections with S355 steel:

    UC 254 x 254 x 89 S275 subject to axial load.

    Answer: at least class 2

    UC 203 x 203 x 46 S355 subject to bending.

    Answer: at least class 2

    UB 457 x 152 x 60 S355 subject to bending.

    Answer: at least class 2

    UB 457 x 152 x 60 S355 subject to axial force1500kN.

    Answer: class 4