1.5 PCD1 – modular, expandable, compact CPU...66 saia-pcd.com PCD1 M1 Slot A X2 X1 X0 X3 142 49...

10
65 saia-pcd.com PCD1 Automation stations – Saia PCD1 5 Switch cabinet components 4 Consumer data acquisition 3 Dedicated room controllers 2 Operation and monitoring 1 Automation stations Saia PCD® E-Controller (PCD1.M0160E0) Page The E-controller in compact design includes in the default delivery condition S-Monitoring (energy)-functionalities, which can be customized with Saia PG5 Type: PCD1.M0160E0 with S-Monitoring function 18 integrated E/As no free I/O slots The Saia PCD1 systems are the smallest programmable Saia PCD® controllers in a flat design. Along with the standard communication interfaces, integrated data memory and web/IT functionality, all controllers also have at least 18 integrated I/Os. The PCD1 controllers are ideally suited to small-scale automation tasks, whose challenges and tasks can be successfully processed by the powerful CPU. The many communication options are another advantage: Ethernet TCP/IP, USB port, the onboard RS-485 interface and the expansion options with BACnet® or Lon IP, for instance, are a small sample of the performance capability of PCD1. 1.5 PCD1 – modular, expandable, compact CPU 1.5.2 Saia PCD1.Room (PCD1.M2110R1) Page Saia PCD1.Room is for applications in the field of room automation and HeaVAC. Type PCD1.M2110R1 with Ethernet TCP/IP for room automation applications 24 integrated I/Os 1 free I/O slot 1.5.1 Saia PCD1.M2 series Page Saia PCD1.M2xxx are compact and may be expanded via modules. Types PCD1.M2160 with Ethernet TCP/IP and expanded memory PCD1.M2120 with Ethernet TCP/IP 18 integrated I/Os 2 free I/O slots Potential use in primary switch cabinet Potential use in a room (example: in a room box) Saia PCD1.M2220-C15 Page The E-Line control is ideally suited by the compact design for installation in an electrical sub-distribution. It can be used for example for the other E-Line modules as zoning / master station. Type: PCD1.M2220-C15 E-Line CPU with Ethernet, 512kB integriatede I/Os (4 DI, 2AI, 1 WD) two free I/O Slots a variety of communication options 70 66 150 75

Transcript of 1.5 PCD1 – modular, expandable, compact CPU...66 saia-pcd.com PCD1 M1 Slot A X2 X1 X0 X3 142 49...

Page 1: 1.5 PCD1 – modular, expandable, compact CPU...66 saia-pcd.com PCD1 M1 Slot A X2 X1 X0 X3 142 49 226 Automation stations – Saia PCD1 1.5.1 Saia PCD1.M2xxx controller The Saia PCD1.M2xxx

65

saia-pcd.com

PCD1

Automation stations – Saia PCD1

5Sw

itch

cabi

net

com

pone

nts

4Co

nsum

er

data

acq

uisi

tion

3D

edic

ated

ro

om c

ontr

olle

rs2

Ope

ratio

n

and

mon

itori

ng1

Aut

omat

ion

stat

ions

Saia PCD® E-Controller (PCD1.M0160E0) Page

The E-controller in compact design includes in the default delivery condition S-Monitoring (energy)-functionalities, which can be customized with Saia PG5

Type: PCD1.M0160E0 with S-Monitoring function 18 integrated E/As no free I/O slots

The Saia PCD1 systems are the smallest programmable Saia PCD® controllers in a flat design. Along with the standard communication interfaces, integrated data memory and web/IT functionality, all controllers also have at least 18 integrated I/Os. The PCD1 controllers are ideally suited to small-scale automation tasks, whose challenges and tasks can be successfully processed by the powerful CPU.

The many communication options are another advantage: Ethernet TCP/IP, USB port, the onboard RS-485 interface and the expansion options with BACnet® or Lon IP, for instance, are a small sample of the performance capability of PCD1.

1.5 PCD1 – modular, expandable, compact CPU

1.5.2 Saia PCD1.Room (PCD1.M2110R1) Page

Saia PCD1.Room is for applications in the field of room automation and HeaVAC.Type PCD1.M2110R1 with Ethernet TCP/IP

for room automation applications

24 integrated I/Os 1 free I/O slot

1.5.1 Saia PCD1.M2 series Page

Saia PCD1.M2xxx are compact and may be expanded via modules.Types PCD1.M2160 with Ethernet TCP/IP and expanded memory PCD1.M2120 with Ethernet TCP/IP

18 integrated I/Os2 free I/O slots

Potential use in primary switch cabinet

Potential use in a room (example: in a room box)

Saia PCD1.M2220-C15 Page

The E-Line control is ideally suited by the compact design for installation in an electrical sub-distribution. It can be used for example for the other E-Line modules as zoning / master station. Type: PCD1.M2220-C15 E-Line CPU with Ethernet, 512kB integriatede I/Os (4 DI, 2AI, 1 WD) two free I/O Slots a variety of communication options

70

66

150

75

Page 2: 1.5 PCD1 – modular, expandable, compact CPU...66 saia-pcd.com PCD1 M1 Slot A X2 X1 X0 X3 142 49 226 Automation stations – Saia PCD1 1.5.1 Saia PCD1.M2xxx controller The Saia PCD1.M2xxx

66

saia-pcd.com

PCD1

M1

Slot A

X2 X1 X0

X3

142 49

226

Automation stations – Saia PCD1

1.5.1 Saia PCD1.M2xxx controller

The Saia PCD1.M2xxx series is a compact controller with onboard I/Os and in addition two free I/O slots for plug-in or communication interface modules. The Web/IT functionality, the onboard memory, the range of standard communication interfaces and the expansion options offer ideal solutions for small to medium systems.

Device design

Mounting Dimensions Power supply and connection concept

Additional information is provided in the Chapter Saia PCD3 power supply and connection concept, and in the Manual 26-875.

on a level surface on two DIN rails ( 2 × 35 mm in accordance with DIN EN 60715 TH35)

Compact mass: 142 × 226 × 49 mm

Types

PCD1.M2160 with Ethernet TCP/IP and expanded memory PCD1.M2120 with Ethernet TCP/IP PCD1.M2020 without Ethernet TCP/IP

System properties Up to 50 inputs/outputs

May be expanded remotely with RIO PCD3.T66x or PCD3.T76x

Up to 8 communication interfaces

USB and Ethernet interface onboard

Large onboard memory for programs (up to 1 MB) and data (up to 128 MB file system)

Automation Server for integration into Web/IT systems

Automation Server integrated in the base

unitSlot for memory modules

Terminals for integrated inputs and outputs

Terminals for optional connection (slot A)

2 free slots with SPI (high-speed serial Bus) for I/O or communication modules

Voltage supply 24 VDC Watchdog relay

RS-485 interface

Ethernet connection (2-port switch)

USB port

Operating LEDs

Slot for communication

interfaces

Battery

RUN/STOP button

Supply

Ground bar

1.5 mm2 / max. 25 cm

IO0 IO1

Page 3: 1.5 PCD1 – modular, expandable, compact CPU...66 saia-pcd.com PCD1 M1 Slot A X2 X1 X0 X3 142 49 226 Automation stations – Saia PCD1 1.5.1 Saia PCD1.M2xxx controller The Saia PCD1.M2xxx

67

saia-pcd.com

PCD1

Automation stations – Saia PCD1

5Sw

itch

cabi

net

com

pone

nts

4Co

nsum

er

data

acq

uisi

tion

3D

edic

ated

ro

om c

ontr

olle

rs2

Ope

ratio

n

and

mon

itori

ng1

Aut

omat

ion

stat

ions

Memory and file system Types: PCD1.M2160 PCD1.M2120

Program memory, DB/Text (Flash) 1 MB 512 kByte

User memory, DB/Text (RAM) 1 MB 128 kByte

Onboard user flash file system 128 MB 8 MB

Integrated communicationEthernet connection (2-port switch) 10/100 Mbit/s, full-duplex, auto-sensing, auto-crossing Yes Yes

USB port USB 1.1 device 12 Mbit/s Yes Yes

RS-485 (terminal X3), up to 115 kbit/s Yes Yes

Overview Saia PCD1.M2xxx

Onboard inputs/outputs

Inputs:6 Digital inputs (4 + 2 interrupts) 15…30 VDC, 3 ms input filter (0.2 ms for the interrupts) Terminal X12 Analogue inputs, selectable via DIP switch –10…+10 VDC, 0…±20 mA, Pt1000, Ni1000, Ni1000 L&S, 0…2.5 kΩ,

12 bit resolution Terminal X1

Outputs:4 Digital outputs 24 VDC / 0.5 A Terminal X01 PWM output 24 VDC / 0.2 A Terminal X0

selectable/configurable via PG54 Digital inputs or outputs 24 VDC / data as digital inputs or outputs Outputs: Terminal X01 Watchdog relay or make contact 48 VAC or VDC, 1 A With DC switching voltage a free-wheeling diode should be

connected in parallel to the load Terminal X3

General specificationsOperating voltage 24 VDC, –20/+25 % max. inkl. 5% ripple (in accordance with EN/IEC 61131-2)Battery for data backup (replaceable) Lithium battery with a service life of 1 to 3 yearsOperating temperature: 0…55 °CDimensions (W × H × D) 142 × 226 × 49 mmMounting location 2× DIN rails in accordance with DIN EN60715 TH35 (2 × 35 mm) or on a flat surfaceProtection type IP 20Capacity 5 V/+V (24 V) internal max. 500 mA/200 mAPower consumption typically 12 W

Plug-in I/O modules for slots I/O 0 and I/O 1The modules listed in the PCD2.M5 series (Chapter 1.4) are also used for the Saia PCD1 series.

Detent latch Bus connector

I/O 0 I/O 1

Technical data

Analogue output module Saia PCD7.W600 This module has 4 analogue outputs 0 to +10 V with a 12-bit resolution and has been specifically developed for the new PCD1 CPUs (PCD1.M2xxx, PCD1.M0160E0, PCD1.M2110R1). It can be plugged into slot A of the PCD1 CPU like the PCD7.F1xxS communication module.

Page 4: 1.5 PCD1 – modular, expandable, compact CPU...66 saia-pcd.com PCD1 M1 Slot A X2 X1 X0 X3 142 49 226 Automation stations – Saia PCD1 1.5.1 Saia PCD1.M2xxx controller The Saia PCD1.M2xxx

68

saia-pcd.com

PCD1

M1

Slot A

X2 X1 X0

X3

PCD7.R55xM04

PCD7.R610

Automation stations – Saia PCD1

CommunicationElectrical isolation

Internal current con-sumption 5V +V (24 V) Slot

I/O con-nector type 1)

PCD7.F110S RS-485/RS-422 --- 40 mA – Slot A

PCD7.F121S RS-232 with RTC/CTS, DTR/DSR, DCD suitable for modem, EIB connection --- 15 mA – Slot A

PCD7.F150S RS-485 with termination resistors that can be activated 130 mA – Slot A

PCD7.F180S Belimo MP-Bus, for connecting up to 8 drives on one line --- 15 mA 15 mA Slot A

PCD2.F2100 RS-422/RS-485 plus PCD7.F1xxS as option --- 110 mA – IO 0/1 2× K

PCD2.F2150 BACnet® MS/TP RS-485 plus PCD7.F1xxS as an option --- 110 mA – IO 0/1 2× K

PCD2.F2210 RS-232 plus PCD7.F1xxS as an option --- 90 Ma – IO 0/1 2× K

PCD2.F2400 LonWorks® interface module --- 90 Ma – IO 0/1 L9

PCD2.F2610 DALI Master for up to 64 DALI devices --- 90 Ma – IO 0/1 L

PCD2.F27x0 M-Bus master with 2 M-Bus interfaces --- 70 mA 8 mA IO 0/1 L

PCD2.F2810 Belimo MP-Bus plus PCD7.F1xxS as an option --- 90 Ma 15 mA IO 0/1 2× K

1) Plug-in I/O terminal blocks are included with I/O modules. Spare terminals, ribbon connectors with system cables and separate terminals are ordered as accessories.

In addition to the onboard interfaces, the interface functions can also be expanded in a modular way using the various slots. Numerous protocols are therefore supported by the Saia PCD1.M2 series. Detailed information and an overview is contained in the Chapter BA communication systems.

Saia PCD1.M2xxx interface options

System properties of PCD2.F2xxx modules

The following points must be noted when using the PCD2.F2xxx interface modules: Max. 2 modules PCD2.F2xxx (4 interfaces) can be used in slots I/O 0/1 per PCD1.M2 system. Consult the information and examples provided in the Manual 26-875 for PCD1.M2 to determine

the maximum communication capacity for each PCD1.M2 system.

Memory expansion and communication

PCD7.R550M04 Flash memory module with a 4 MB file system (for user program backup, web pages, etc.) M1

PCD7.R560 Flash memory module for BACnet® firmware M1

PCD7.R562 Flash memory module for BACnet® firmware with 128 MB file system M1

PCD7.R580 Flash memory module for Lon IP firmware M1

PCD7.R582 Flash memory module for Lon IP firmware with 128 MB file system M1

PCD7.R610 Basic module for Micro SD flash card M1

PCD7.R-MSD1024 Micro SD flash card 1024 MB, PCD formatted PCD7.R610

The onboard memory of the Saia PCD1.M2xxx can be expanded using a Saia PCD7.Rxxx module in slot M1. In addition, the Saia PCD1.M21x0 can be expanded with BACnet® IP or Lon IP. Additional information about the memory management and structure is contained in the Chapter Saia PCD® System Description.

The use of external modem modules such as Q.M716-KS1 is recommended. The PCD2.T8xx modem modules can only be used with a PCD7.F121S module. External wiring is therefore required.

Memory modules

IO0 IO 1

Page 5: 1.5 PCD1 – modular, expandable, compact CPU...66 saia-pcd.com PCD1 M1 Slot A X2 X1 X0 X3 142 49 226 Automation stations – Saia PCD1 1.5.1 Saia PCD1.M2xxx controller The Saia PCD1.M2xxx

69

saia-pcd.com

PCD1

Automation stations – Saia PCD1

5Sw

itch

cabi

net

com

pone

nts

4Co

nsum

er

data

acq

uisi

tion

3D

edic

ated

ro

om c

ontr

olle

rs2

Ope

ratio

n

and

mon

itori

ng1

Aut

omat

ion

stat

ions

Accessories and consumables for Saia PCD1.M2xxx

For small and medium systems Modernisation and expansion of existing systems through, for example, the compact construction Versatile interface options, including to existing systems as a gateway, for example: optimisation of a cooling system

by setting all the free parameters

Battery for data backupType Description

4 507 4817 0 Lithium battery for PCD processor unit (RENATA button battery type CR 2032)

Plug-in screw terminal block4 405 5089 0 Plug-in screw terminal block, 11-pin, labelling 0…10 Terminal X04 405 5087 0 Plug-in screw terminal block, 9-pin, labelling 11…19 Terminal X14 405 5088 0 Plug-in screw terminal block, 10-pin, labelling 20…29 Terminal X24 405 4919 0 Plug-in screw terminal block, 10-pin, labelling 30…39 Terminal X3

Cover4 104 7759 0 Housing cover for PCD1.M2xxx without logo on-site with an overlay that can be individually designed

Labelling

The self-adhesive labels can be printed direct with the SBC LabelEditor from the PG5 Device Configurator

Use as communication interface with M-Bus in a district heating network

Range of uses

Connection to an existing EIB/KNX installation providing conference rooms with a web connection

The EPLAN® electric P8 macros are available on the support site. The macros and article data are also provided on the EPLAN® data portal.

EPLAN macros

EPLAN macros are available for project planning and engineering.

Page 6: 1.5 PCD1 – modular, expandable, compact CPU...66 saia-pcd.com PCD1 M1 Slot A X2 X1 X0 X3 142 49 226 Automation stations – Saia PCD1 1.5.1 Saia PCD1.M2xxx controller The Saia PCD1.M2xxx

70

saia-pcd.com

PCD1

142 49

226

Automation stations – Saia PCD1

1.5.2 Saia PCD1.Room (PCD1.M2110R1)

Saia PCD1.Room (PCD1.M2110R1) is a programmable room controller for complex solutions with many commu-nication options. In addition to the I/Os that are already integrated, the controller has a free I/O slot for individual expansion with inputs/outputs or communication options. Web/IT functions for mobile operation, for instance, are also already onboard. Furthermore, Saia PCD1.Room offers various possibilities for integrating other systems in the room using standard communication interfaces. (Energy) efficient and individual room automation can be easily implemented as a result. The controller also provides a good basis for achieving the energy efficiency classes in accordance with EN 15232:2012.

Lighting, sun protection and individual room regulation can be optimally coordinated with one another with this controller. This example showing possible assignments was compiled based on applications in accordance with the VDI 3813 list of room automation functions and the DIN EN 15232 list of building automation functions.

1×serial communication RS-485: e.g. connec-tion external receiver EnOcean

1× make contact 48 VAC e.g. switching contact

Power supply 24 VDC

USB port

Ethernet connection (2-port switch) e.g. to the Internet (remote control via browser is possible as a result)

1×optional terminals for serial communication depending on the PCD7.F1xxS module e.g. – MP-Bus (with

PCD7.F180S) for Belimo actuating drives.

2× analogue inputs: – 10…+10 VDC, 0…+/–20 mA,

Pt1000, Ni1000, Ni1000 L&S, 0…2.5 kΩ

e.g. – Brightness measurement– Air temperature measure-ment

6× digital inputs: 15…30 VDCe.g.– Presence detection– Window monitoring

4× Digital inputs/outputs (selectable)24 VDCe.g.– Dewpoint monitoring– Time switch program

5× digital outputs: 24 VDCe.g.– Signal presence– Switch/set binary output

2× analogue outputs: 0…10 VDC, 0(4)…20 mAe.g.– Volume flow control– Adjust temperature setpoint

4× analogue inputs: 0…10 VDC, 0(4)…20 mA, Pt500, Pt1000, Ni1000e.g.– Air quality measurement– Precipitation detection

Expansion options I/O or com-munication module e.g. DALI (PCD2.F2610)

Device design with connection example

The Smart RIO Manager function is not supported!

Mounting Dimensions Power supply and connection concept

Further information is provided in the Chapter Saia PCD3 power supply and connection concept, and in the Manual 26-875.

on two DIN rails (2 × 35 mm in accordance with DIN EN 60715 TH35)

on a level surface

Supply

Ground bar

1.5 mm2 / max. 25 cm

Compact mass:142 × 226 × 49 mm

Page 7: 1.5 PCD1 – modular, expandable, compact CPU...66 saia-pcd.com PCD1 M1 Slot A X2 X1 X0 X3 142 49 226 Automation stations – Saia PCD1 1.5.1 Saia PCD1.M2xxx controller The Saia PCD1.M2xxx

71

saia-pcd.com

PCD1

Automation stations – Saia PCD1

5Sw

itch

cabi

net

com

pone

nts

4Co

nsum

er

data

acq

uisi

tion

3D

edic

ated

ro

om c

ontr

olle

rs2

Ope

ratio

n

and

mon

itori

ng1

Aut

omat

ion

stat

ions

Overview of Saia PCD1.Room (PCD1.M2110R1)

Onboard inputs/outputsInputs:6 Digital inputs (4 + 2 interrupts) 15…30 VDC, 3 ms / 0.2 ms input filter Terminal X12 Analogue inputs, selectable via DIP switch –10…+10 VDC, 0…±20 mA,

Pt1000, Ni1000, Ni1000 L&S, 0…2.5 kΩ, 12 bit resolution Terminal X1

4 Analogue inputs, selectable via DIP switch 0…10 VDC, 0(4)…20 mA, Pt1000, Pt 500, Ni1000, 14 bit resolution IO 1

Outputs:4 Digital outputs 24 VDC / 0.5 A Terminal X01 PWM output 24 VDC / 0.2 A Terminal X02 Analogue outputs, selectable via PG5 0…10 VDC or 0(4)…20 mA, 12 bit resolution IO 1

selectable/configurable via PG54 Digital inputs or outputs 24 VDC / data as digital inputs or digital outputs Terminal X01 Watchdog relay or as make contact 48 VAC or VDC, 1 A

With DC switching voltage a free-wheeling diode should be connected in parallel to the load

Terminal X3

General specificationsOperating voltage 24 VDC, –20/+25 % max. inkl. 5% ripple (in accordance with EN/IEC 61131-2)Battery for data backup (replaceable) Lithium battery with a service life of 1 to 3 yearsOperating temperature: 0…55 °CDimensions (W × H × D) 142 × 226 × 49 mmMounting location 2× DIN rails in accordance with DIN EN60715 TH35 (2 × 35 mm) or on a smooth surfaceProtection type IP 20Capacity 5 V/+V (24 V) internal max. 500 mA/200 mAPower consumption typically 12 WAutomation Server Flash memory, file system, FTP and web server, email, SNMP

Only a PCD2.W525 module that is already supplied with the controller in the default setup functions in slot I/O 1. If the module is removed, the controller will go to Stop!

Plug-in I/O modules for slot I/O 0

The modules listed in the PCD2.M5 series (Chapter 1.4) are also used for the Saia PCD1 series.

Memory and file system Type: PCD1.M2110R1Program memory, DB/text (Flash) 256 kByte

User memory, DB/text (RAM) 128 kByte

Onboard user flash file system 8 MB Integrated communicationEthernet connection (2-port switch) – 10/100 Mbit/s, full-duplex, auto-sensing, auto-crossing yesUSB port – USB 1.1 device 12 Mbit/s yesRS-485 – (terminal X3), up to 115 kbit/s yes

Technical data

Automation Server Integrated

into the base unit

Detent latch Bus connector

I/O 0 I/O 1

Analogue output module Saia PCD7.W600 This module has 4 analogue outputs 0 to +10 V with a 12-bit resolution and has been developed specifically for use with the new PCD1 CPUs (PCD1.M2xx0, PCD1.M0160E0, PCD1.M2110R1). It can be plugged into slot A of the PCD1 CPU like the PCD7.F1xxS communication module.

Page 8: 1.5 PCD1 – modular, expandable, compact CPU...66 saia-pcd.com PCD1 M1 Slot A X2 X1 X0 X3 142 49 226 Automation stations – Saia PCD1 1.5.1 Saia PCD1.M2xxx controller The Saia PCD1.M2xxx

72

saia-pcd.com

PCD1

W Modul

M1

Slot A

X2 X1 X0

X3

PCD7.R55xM04

PCD7.R610

Automation stations – Saia PCD1

In addition to the onboard interfaces, the interface functions can also be expanded in a modular way using the various slots. Numerous protocols are therefore supported by the Saia PCD1.M2110R1. A detailed list of all the protocols can be found in the Chapter BA communication systems.

Saia PCD1.Room (PCD1.M2110R1) interface options

System properties of PCD2.F2xxx modules

The following points must be noted when using the PCD2.F2xxx interface modules: Per PCD1.M2110R1 Room Edition a max. of 1 module PCD2.F2xxx (2 interfaces) can be used with slot I/O0. Consult the information and examples provided in the Manual 27-619 for PCD1.M2110R1 to determine the maximum

communication capacity for each PCD1.M2 system.

The onboard memory can be expanded using a PCD7.Rxxx module in slot M1. In addition, BACnet® IP or Lon IP can be activated.Additional information about the memory management and structure is contained in the Chapter Saia PCD® System description.

Memory modules

IO 0

Memory expansion and communication

PCD7.R550M04 Flash memory module with a 4 MB file system (for user program backup, web pages, etc.) M1

PCD7.R560 Flash memory module for BACnet® firmware, M1

PCD7.R562 Flash memory module for BACnet® firmware with 128 MB file system M1

PCD7.R580 Flash memory module for Lon IP firmware M1

PCD7.R582 Flash memory module for Lon IP firmware with 128 MB file system M1

PCD7.R610 Basic module for Micro SD flash card M1

PCD7.R-MSD1024 Micro SD flash card 1024 MB, PCD formatted PCD7.R610

CommunicationElectrical isolation

Internal current con-sumption 5V +V (24 V) Slot

I/O con-nector type 1)

PCD7.F110S RS-422 avec RTS/CTS ou RS-485 2) --- 40 mA – Slot A

PCD7.F121S RS-232 with RTC/CTS, DTR/DSR, DCD, suitable for modem or EIB connection --- 15 mA – Slot A

PCD7.F150S RS-485 2) 130 mA – Slot A

PCD7.F180S Belimo MP-Bus, for connecting up to 8 drives on one line --- 15 mA 15 mA Slot A

PCD2.F2100 RS-422/RS-485 2), plus PCD7.F1xxS en option --- 110 mA – IO 0/1 2× K

PCD2.F2150 BACnet® MS/TP RS-485 plus PCD7.F1xxS as an option --- 110 mA – IO 0/1 2× K

PCD2.F2210 RS-232 plus PCD7.F1xxS as an option --- 90 Ma – IO 0/1 2× K

PCD2.F2400 LonWorks® interface module --- 90 Ma – IO 0/1 L9

PCD2.F2610 DALI master for up to 64 DALI devices --- 90 Ma – IO 0/1 L

PCD2.F27x0 M-Bus master with 2 M-Bus interfaces --- 70 mA 8 mA IO 0/1 L

PCD2.F2810 Belimo MP-Bus plus PCD7.F1xxS as an option --- 90 Ma 15 mA IO 0/1 2× K

1) Plug-in I/O terminal blocks are supplied with I/O modules. Spare terminals, ribbon connectors with system cables and separate terminals are ordered as accessories.

2) with line termination resistors that can be activated.

Page 9: 1.5 PCD1 – modular, expandable, compact CPU...66 saia-pcd.com PCD1 M1 Slot A X2 X1 X0 X3 142 49 226 Automation stations – Saia PCD1 1.5.1 Saia PCD1.M2xxx controller The Saia PCD1.M2xxx

73

saia-pcd.com

PCD1

Automation stations – Saia PCD1

5Sw

itch

cabi

net

com

pone

nts

4Co

nsum

er

data

acq

uisi

tion

3D

edic

ated

ro

om c

ontr

olle

rs2

Ope

ratio

n

and

mon

itori

ng1

Aut

omat

ion

stat

ions

Accessories and consumables for Saia PCD1.Room (PCD1.M2110R1)

Applications must take the exact number of I/Os into account. Coupling relays (e.g.: PCD7.L252) or S-Bus RIOs (PCD7.L200/L210) required. The S-Bus stations are limited to a maximum of 10 units per PCD1.Room. The same applies to Modbus stations (total of 10 units).

The EPLAN® electric P8 macros are available on the support site. The macros and article data are also provided on the EPLAN® data portal.

EPLAN macros

EPLAN macros are available for project planning and engineering

Battery for data backupType Description

4 507 4817 0 Lithium battery for PCD processor unit (RENATA button battery type CR 2032)

Plug-in screw terminal block4 405 5089 0 Plug-in screw terminal block, 11-pin, labelling 0…10 Terminal X04 405 5087 0 Plug-in screw terminal block, 9-pin, labelling 11…19 Terminal X14 405 5088 0 Plug-in screw terminal block, 10-pin, labelling 20…29 Terminal X2

Cover4 104 7759 0 Housing cover for PCD1.M2xxx without SBC logo on-site with an overlay that can be individually designed

Range of uses:

Labelling

The self-adhesive labels can be printed direct with the SBC LabelEditor from the PG5 Device Configurator

Options for programmable applications: Radiators Fan coil applications Cooling ceiling VAV – variable air volume Air quality control Signal contacts (occupancy control,

presence detection, window monitoring) Lighting control Blind control etc.

Connection options via the following:

Analogue signals (onboard) S-Bus (onboard) Modbus (onboard) Internet access, web server (onboard) BACnet® with PCD7.R56x (slot M1) BACnet® MS/TP with PCD2.F2150 (slot I/O 0) Lon IP with PCD7.R58x (slot M1)

Lon FTT 10 with PCD2.F2400 (slot I/O 0) KNX over IP (IP onboard) KNX TP with an external coupler EnOcean with external receiver

Applications Room control units

Page 10: 1.5 PCD1 – modular, expandable, compact CPU...66 saia-pcd.com PCD1 M1 Slot A X2 X1 X0 X3 142 49 226 Automation stations – Saia PCD1 1.5.1 Saia PCD1.M2xxx controller The Saia PCD1.M2xxx

74

saia-pcd.com

PCD1

Automation stations – Saia PCD1