146256408 BTS3900 Configuration
description
Transcript of 146256408 BTS3900 Configuration
-
BTS3900 Configuration Level: internal
2009-7-2 Page1, Total17
BTS3900 Configuration Guideline
Drafted by Quan Kuifa Date JUN.10.2009
Reviewed by Date
Approved by Date
Huawei Technologies Co., Ltd.
All rights reserved.
-
BTS3900 Configuration Level: internal
2009-7-2 Page2, Total17
This guide instructs that how to configur BTS3900 in the BSC6000.also that how to implement BTS swap.All the operations is based on the LMT and MML. The content of this guide is as below: 1, Main process of BTS configuration 2, Alarm configuration for BTS 3, Data configuration for BTS swap
-
BTS3900 Configuration Level: internal
2009-7-2 Page3, Total17
1. Main process of BTS configuration Keep the same configuartion with site Batna CCLT 05503 in the Batna. Step1: add site
Step2: add cell
-
BTS3900 Configuration Level: internal
2009-7-2 Page4, Total17
Step3: set attributes
-
BTS3900 Configuration Level: internal
2009-7-2 Page5, Total17
Step4: add FMU and GATM board (Each BTS3900 is configured with 6 DRFU.1 FMU.1 GATM.1 BBU.) Add FMU in slot 8 and GATM in slot 17, because the monitor signal cable of FMU and GATM are connected to MON0 and MON1 of UPEU separately.which keeps the confiuration same with the practical installation.
-
BTS3900 Configuration Level: internal
2009-7-2 Page6, Total17
Step5: add RXU Chain
-
BTS3900 Configuration Level: internal
2009-7-2 Page7, Total17
Use the RF cable connection tool to generate the connection. For the site 05503(S4/4/4) is as below:
-
BTS3900 Configuration Level: internal
2009-7-2 Page8, Total17
Step6: add RXU (RFU) Principia for RXUs name: PortX_SlotX_PosX. PortX: Port No. X of GTMU SlotX: Slot No. X of DRFU PosX: Position No.X of the DRFU in the chain.
Keep confiuration same with the practical connection.Finally the RXU chain topo is as below.
-
BTS3900 Configuration Level: internal
2009-7-2 Page9, Total17
Step7: bind logical TRX From Trx No.0 to Trx No.11
Step8: Set TRX attributes (Send Receive Mode)
-
BTS3900 Configuration Level: internal
2009-7-2 Page10, Total17
Set the Send Receive Mode due to pratical situation. Because just one ANT port of DRFU is used, the Single Antenna Double Receiver is chosen.
Step9: Set cell attributes Almost the configuration process is same with BSC32. One parameter should be cared, which isPower Type. 20W is chosen due to the Send Receive Mode.
-
BTS3900 Configuration Level: internal
2009-7-2 Page11, Total17
2. Alarm configuration for BTS3900 The BBU can support 2 RS485 bus and 16 line of on-off alarm maximally. There are just 1 UPEU configured in BTS3900 in the packeting list. The No. of on-off alarm for UPEU is as below.
The monitor signal of DCDU-01 is connected to No.8 alarm of EXT-ALM0 of UPEU. Step1: set site attributes
Step2: set Alarm Shield Flag 2 (Hex) The 8 bits (from low to high) of alarm sheild flag 2 determines the No.8-15 on-off alarm. 0 means shield, 1 means non-shield. The alarm sheild flag 2 is set as 01 to enable the DCDU-01 arlarm.
-
BTS3900 Configuration Level: internal
2009-7-2 Page12, Total17
Step3: set Alarm Voltage Definition
-
BTS3900 Configuration Level: internal
2009-7-2 Page13, Total17
Step4: set external alarm port Set the external alarm port for the on-off alarm of the UPEU as below.
Step5: name the external alarm Click the Alarm Matintenance in the LMT mean
Find the No.5048 alarm.then right-click it.choose as below.
-
BTS3900 Configuration Level: internal
2009-7-2 Page14, Total17
Set the Alarm name.
-
BTS3900 Configuration Level: internal
2009-7-2 Page15, Total17
3. Data configuration for BTS swap Step1: configure the site with LMT in offline mode Note: Configure the site on the same slot and port as the site to be swapped.
Step2: export the site data in offline mode
It will take about 5 minutes to export one site data. Step3: backup the data of the swapped site in online mode Note: do this after blocking the site.
-
BTS3900 Configuration Level: internal
2009-7-2 Page16, Total17
The exported result is the format of text as above, which will be used to edit the adjacent cell for BTS3900 later. Step4: delete the swapped site in online mode
Step5: import the data in online mode
-
BTS3900 Configuration Level: internal
2009-7-2 Page17, Total17
The log above indicates that importing is successful. Step6: edit the MML script Use the UltraEdit tool to edit the exported file namedBTS3900 adjacent cell above. CommanADD CELL2GNC will be used to add adjacent cell. Its very to edit the MML script with the UltraEdit tool in column mode. Take care theBidirectional Adjacent CellandSingle directional Adjacent Cell! For the theBidirectional Adjacent Cell, command ADD CELL2GNC should be executed twice to add adjacent cell in both cell. Step7: execute the MML script in batch Log in the MML and execute the scriptBTS3900 adjacent cell in batch.
/ColorImageDict > /JPEG2000ColorACSImageDict > /JPEG2000ColorImageDict > /AntiAliasGrayImages false /CropGrayImages true /GrayImageMinResolution 300 /GrayImageMinResolutionPolicy /OK /DownsampleGrayImages true /GrayImageDownsampleType /Bicubic /GrayImageResolution 300 /GrayImageDepth -1 /GrayImageMinDownsampleDepth 2 /GrayImageDownsampleThreshold 1.50000 /EncodeGrayImages true /GrayImageFilter /DCTEncode /AutoFilterGrayImages true /GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict > /GrayImageDict > /JPEG2000GrayACSImageDict > /JPEG2000GrayImageDict > /AntiAliasMonoImages false /CropMonoImages true /MonoImageMinResolution 1200 /MonoImageMinResolutionPolicy /OK /DownsampleMonoImages true /MonoImageDownsampleType /Bicubic /MonoImageResolution 1200 /MonoImageDepth -1 /MonoImageDownsampleThreshold 1.50000 /EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode /MonoImageDict > /AllowPSXObjects false /CheckCompliance [ /None ] /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false /PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXOutputIntentProfile () /PDFXOutputConditionIdentifier () /PDFXOutputCondition () /PDFXRegistryName () /PDFXTrapped /False
/Description > /Namespace [ (Adobe) (Common) (1.0) ] /OtherNamespaces [ > /FormElements false /GenerateStructure true /IncludeBookmarks false /IncludeHyperlinks false /IncludeInteractive false /IncludeLayers false /IncludeProfiles true /MultimediaHandling /UseObjectSettings /Namespace [ (Adobe) (CreativeSuite) (2.0) ] /PDFXOutputIntentProfileSelector /NA /PreserveEditing true /UntaggedCMYKHandling /LeaveUntagged /UntaggedRGBHandling /LeaveUntagged /UseDocumentBleed false >> ]>> setdistillerparams> setpagedevice
BTS3900 Configuration
Level: internal
BTS3900 Configuration Guideline
Drafted by
Quan Kuifa
Date
JUN.10.2009
Reviewed by
Date
Approved by
Date
Huawei Technologies Co., Ltd.
All rights reserved.
This guide instructs that how to configur BTS3900 in the BSC6000.also that how to implement BTS swap.All the operations is based on the LMT and MML.
The content of this guide is as below:
1, Main process of BTS configuration
2, Alarm configuration for BTS
3, Data configuration for BTS swap
1. Main process of BTS configuration
Keep the same configuartion with site Batna CCLT 05503 in the Batna.
Step1: add site
Step2: add cell
Step3: set attributes
Step4: add FMU and GATM board
(Each BTS3900 is configured with 6 DRFU.1 FMU.1 GATM.1 BBU.)
Add FMU in slot 8 and GATM in slot 17, because the monitor signal cable of FMU and GATM are connected to MON0 and MON1 of UPEU separately.which keeps the confiuration same with the practical installation.
Step5: add RXU Chain
Use the RF cable connection tool to generate the connection. For the site 05503(S4/4/4) is as below:
Step6: add RXU (RFU)
Principia for RXUs name: PortX_SlotX_PosX.
PortX: Port No. X of GTMU
SlotX: Slot No. X of DRFU
PosX: Position No.X of the DRFU in the chain.
Keep confiuration same with the practical connection.Finally the RXU chain topo is as below.
Step7: bind logical TRX
From Trx No.0 to Trx No.11
Step8: Set TRX attributes (Send Receive Mode)
Set the Send Receive Mode due to pratical situation. Because just one ANT port of DRFU is used, the Single Antenna Double Receiver is chosen.
Step9: Set cell attributes
Almost the configuration process is same with BSC32.
One parameter should be cared, which isPower Type. 20W is chosen due to the Send Receive Mode.
2. Alarm configuration for BTS3900
The BBU can support 2 RS485 bus and 16 line of on-off alarm maximally.
There are just 1 UPEU configured in BTS3900 in the packeting list.
The No. of on-off alarm for UPEU is as below.
The monitor signal of DCDU-01 is connected to No.8 alarm of EXT-ALM0 of UPEU.
Step1: set site attributes
Step2: set Alarm Shield Flag 2 (Hex)
The 8 bits (from low to high) of alarm sheild flag 2 determines the No.8-15 on-off alarm. 0 means shield, 1 means non-shield.
The alarm sheild flag 2 is set as 01 to enable the DCDU-01 arlarm.
Step3: set Alarm Voltage Definition
Step4: set external alarm port
Set the external alarm port for the on-off alarm of the UPEU as below.
Step5: name the external alarm
Click the Alarm Matintenance in the LMT mean
Find the No.5048 alarm.then right-click it.choose as below.
Set the Alarm name.
3. Data configuration for BTS swap
Step1: configure the site with LMT in offline mode
Note: Configure the site on the same slot and port as the site to be swapped.
Step2: export the site data in offline mode
It will take about 5 minutes to export one site data.
Step3: backup the data of the swapped site in online mode
Note: do this after blocking the site.
The exported result is the format of text as above, which will be used to edit the adjacent cell for BTS3900 later.
Step4: delete the swapped site in online mode
Step5: import the data in online mode
The log above indicates that importing is successful.
Step6: edit the MML script
Use the UltraEdit tool to edit the exported file namedBTS3900 adjacent cell above.
CommanADD CELL2GNC will be used to add adjacent cell. Its very to edit the MML script with the UltraEdit tool in column mode.
Take care theBidirectional Adjacent CellandSingle directional Adjacent Cell! For the theBidirectional Adjacent Cell, command ADD CELL2GNC should be executed twice to add adjacent cell in both cell.
Step7: execute the MML script in batch
Log in the MML and execute the scriptBTS3900 adjacent cell in batch.
2009-7-2
Page1, Total17