11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de...
-
Upload
laurel-sharlene-garrett -
Category
Documents
-
view
217 -
download
1
Transcript of 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de...
![Page 1: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/1.jpg)
11 B169-0313
Assistance ventriculaire Les produits en développement
Pr Camille DambrinService de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil
![Page 2: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/2.jpg)
2B169-0313
Lead the use of Mechanical Circulatory Support (MCS) to dramatically improve outcomes for patients with advanced heart failure
Continual improvement of clinical outcomes
Transparent, rigorous clinical research
Increasing awareness and education
Technology innovation leadership
Market leadership across the spectrum of MCS
Vision for and commitment to the future of MCS
Our Values / Our Commitments
Thoratec Corporation
![Page 3: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/3.jpg)
33
Assistance à court terme
Acute/Internediate Support
![Page 4: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/4.jpg)
4B169-0313
CentriMag®
Acute/Internediate Support
![Page 5: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/5.jpg)
5B169-0313
CentriMag Recent Additions
2nd Gen Console Surgical Cannulae System Cart Transporter
Available
Acute/Internediate Support
![Page 6: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/6.jpg)
6B169-0313
HeartMate PHP®
*In development. Not approved for clinical use
Acute/Internediate Support
![Page 7: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/7.jpg)
7B169-0313
Cardiac Catheter Pump •Low-profile percutaneous device delivered through
13F sheath
•Expands to 24F across aortic valve
•Designed to deliver over 4 lpm for up to 10 days
Cardiac Catheter Pump •Low-profile percutaneous device delivered through
13F sheath
•Expands to 24F across aortic valve
•Designed to deliver over 4 lpm for up to 10 days
HeartMate PHP*
*In development. Not approved for clinical use
Target Applications
• Acute MI
• Cardiogenic Shock
• High-risk PCI
• Acutely decompensated heart failure
Acute/Internediate Support
![Page 8: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/8.jpg)
88
Assistance à long terme
Chronic Support
![Page 9: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/9.jpg)
9B169-0313
Chronic Support
![Page 10: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/10.jpg)
10B169-0313
Power Unit Evolution
Chronic Support
![Page 11: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/11.jpg)
11
Mobile Power Unit (MPU)*
• Enhanced Functionality
• Easier patient management (1,3 kg)
• Improved mobility and cable management
• Low maintenance (only AAA batteries)
• Long cable (6,4m)
• Safety Design
• Echoes System Controller alarms (even if power is lost)
• Internal Diagnostics
• Improved durability
• Twist resistant cables
• Commercial use targeted for june 2015
Designing for Portable and Patient-Friendly VAD Power
Expected Benefits
Program Status
Chronic Support
![Page 12: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/12.jpg)
12B169-0313
HeartMate II System
Chronic Support
![Page 13: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/13.jpg)
1313
HeartMate® III with Full MagLev™
Designed with a Healthy Respect for the Blood
*Caution: Investigational device. Limited by Federal US law to investigational use
Chronic Support
![Page 14: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/14.jpg)
14B169-0313
What is Full MagLev?
Uses magnets to support all six degrees of freedom of the rotor, such that the rotor remains essentially fixed except for rotation.
(Doesn’t use physical or hydrodynamic/blood bearings)
Chronic Support
![Page 15: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/15.jpg)
15B169-0313
HeartMate III*: Full MagLev™ Technology
Key Design Features: Large and Consistent Gaps (Designed to minimize Shear Stress and Blood Component Activation)
– HeartMate III secondary flow paths are ~0.5 mm along the side, and ~1.0 mm pump above and below the rotor.– Conversely, hydrodynamic bearings are typically operated with much smaller gaps, 0.05 of
a millimeter or so.– HeartMate III pump surfaces are flat and flow is undisturbed; wedging surfaces and other
features required for hydrodynamic bearings are not required.~ 0.5 mm
along the side
~ 1.0 mm top and bottom
Chronic Support
![Page 16: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/16.jpg)
16B169-0313
How much diff erence is there?From a Red Blood Cel l ’s Point of View
Gap Size # of Red Blood Cells
Full MagLev 1,000μm 167
Hydrodynamic Bearing 50μm 8
6-8 μm
Stacked RBCs
Chronic Support
![Page 17: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/17.jpg)
17B169-0313
HeartMate III*: Full MagLev TechnologyKey Design Feature: Pulsatility (Minimize stasis)• These large gaps also enable the rapid speed
changes used by our artificial pulse feature without rotor/housing contact.
• Some potential benefits:• Designed to promote washing of the pump
• Prevents the formation of zones of recirculation and stasis.
• Zero Net Change in Flow• Speed ramps up and down (zero net change)
• Potential Clinical Benefits1-3
• For example, a theorized source of bleeding in chronic support with constant-speed rotary pumps involves the development of arteriovenous malformations, a syndrome associated with persistently low pulse pressure
0.15
2.00
FS
0.20
FS-2000
FS+2000
time [s]
rotor speed [rpm]
1. Tsai H. S., et al. Semin Thromb Hemost 2003;29(5):479-88.2. Malehsa D, Meyer AL, Bara C, Struber M. Eur J Cardiothorac Surg
2009;35:1091-3.3. Crow S, John R, Boyle A, Shumway S, Liao K, Colvin-Adams M, Toninato C,
Missov E, Pritzker M, Martin C, Garry D, Thomas W, Joyce L. J Thorac Cardiovasc Surg 2009;137:208-15.
Chronic Support
![Page 18: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/18.jpg)
1818
L’avenir
The future
![Page 19: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/19.jpg)
19B169-0313
HeartMate Fully Implanted System*(FILVAS)
*In development. Not approved for clinical use
Mobile Tethered Free
The future
![Page 20: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/20.jpg)
20B169-0313
HeartMate Fully Implantable System*
Flexible Lifestyle
Eliminates the driveline and “around the clock” worn equipment.
Forgiving Energy Transfer
• High-efficiency, user-friendly wireless energy transfer across a distance
Designed for Advanced Implantation and Robust Battery Technology
• Custom battery technology tailored for implantable LVAD application
– Expected to provide greater than 3 years of life with slow degradation
• Focus on reduced size and reliability of electronics
Mobile Tethered Free
Breakthrough technology to advance mechanical circulatory support.
*In development. Not approved for clinical use
The future
![Page 21: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/21.jpg)
21B169-0313
Energy Effi ciency and Patient Controller
• Miniaturized System Controller*
• Integrated on-board battery*
*In development. Not approved for clinical use
The future
![Page 22: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/22.jpg)
22B169-0313
HeartMate X*
*In development. Not approved for clinical use
The future
![Page 23: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/23.jpg)
23B169-0313
HeartMate® X*
Ultra-Compact, Highly Versatile VAD = New patient populations
• Potential to meet the needs of earlier stage patients• Potential for minimally invasive implantation• Potential for multiple configurations (LVAD, RVAD, BiVAD)
Expected Benefits
Features• Utilizes proven HeartMate II bearing technology• Partial to Full support (8 L/min) in ultra-compact size• Highly energy efficient• Miniaturized patient peripherals• Left and/or right side assistance
*In development. Not approved for clinical use
The future
![Page 24: 11 B169-0313 Assistance ventriculaire Les produits en développement Pr Camille Dambrin Service de chirurgie cardio-vasculaire, CHU Toulouse-Rangueil.](https://reader038.fdocuments.net/reader038/viewer/2022103023/56649d9e5503460f94a88ae4/html5/thumbnails/24.jpg)
24B169-0313
Minimally Invasive and Multiple Confi gurationsLVAD / RVAD / BiVAD
*In development. Not approved for clinical use
Partial support (design point: 2.5 L/min) Nominal full support (design point: 5.3 L/min) Right sided support (design point: 4.3 L/min)
Designed for up to 8 L/min of flow