101719_2HP2GX_WO_232_2_3L_T8
-
Upload
caballo1986 -
Category
Documents
-
view
7 -
download
4
Transcript of 101719_2HP2GX_WO_232_2_3L_T8
![Page 1: 101719_2HP2GX_WO_232_2_3L_T8](https://reader036.fdocuments.net/reader036/viewer/2022081908/552c34374a79590e7d8b465b/html5/thumbnails/1.jpg)
COOPER LIGHTING
DESCRIPT ION
The 2HP is an energy saving solution for a multitude of applications.
It uses a high performance T8 system that can save up to 40% of
energy costs when compared to standard 3-lamp, 18-cell parabolics.
The 2HP incorporates a 2" precision formed louver into a 97% deep
reflective housing. This combination creates a soft, even distribu-
tion while delivering a highly efficient T8 luminaire. The luminaire is
compatible with all of today’s popular ceiling systems and is avail-
able with a number of options and accessories for increased appli-
cation versatility. The 2HP series is an excellent choice for commer-
cial office spaces, schools, hospitals or retail merchandising areas.
HB Ballast & STD Lamps
228T8 (48), 328T8 (71)
232 (53), 332 (80)
Luminaire Efficacy Rating
LER = FP-83
Catalog Number: 2HP2GX-WO-
232W26P
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $2.89
**Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
2HP2GX228T8328T8
232332
12, 18 Cell
2 ' X 4 ' P A R A B O L I C
2 O R 3 L A M P
H I G H P E R F O R M A N C E T 8
ADF101719
E N E R G Y D A T A
Input Watts:
S PEC IF ICAT ION FEATURES
C o n s t r u c t i o n
Die formed nominal 4-3/4" deep para-
contoured housing made from code
gauge, cold rolled steel. Housing features
die formed stiffeners for added rigidity
along with end plates that securely attach
to housing via interlocking tabs. Other
housing features include a Grid to T-
option (or vice versa) that allows you to
do a conversion in the field. End plates
also have an integral Grid-Lock feature
for safety and convenience. A contoured
ballast/wireway cover rests in the center
of the housing and can be easily
removed without tools, while die formed
captive lamp holders encloses lam-
pholder wiring for easy lampholder
replacement.
E l e c t r i c a l **
Ballasts are CBM/ETL
Class “P” are positively
secured by mounting
bolts. Pressure lock lam-
pholders. UL/CUL listed.
Suitable for damp loca-
tions.
W h i t e O p t i c s
97% reflective White
Optics material with
matching PAF ballast
cover to help maximize
retrofit kit efficiency, distri-
bution, energy savings
and payback.
L o u ve r
Die formed high reflectance white
aluminum (standard). Silver with
semi-specular finish (optional).
Accurate precision parabolic cells
are held in place by interlocking fea-
ture. True-cut mitered corners. Black
reveal with mechanical light seal
around entire perimeter of louver.
Louver protected by polyethylene
cover.
H i n g i n g / L a t ch i n g
Positive cam action spring loaded,
self locking, black steel latches with
safety lock T-hinges allow hinging
and latching from either side.
Catalog # Type
Date
Project
Comments
Prepared by
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TOLOCAL, STATE OR FEDERAL LAWS
Safe and convenient means ofdisconnecting power.
4-3/4"[121mm]
23-3/4"[603mm]
C E I L I N G C O M P A T I B I L I T Y
G
Grid/Lay-in
Standard
T
Concealed T
T
Slot Grid
F
Aluminum Flange Trim
With Supporting
Swing Gates
MZ
Modular Trim
With Supporting
Swing Gates
Ceiling Trim
Type Type
Exposed Grid G
Concealed T G or T
Slot Grid G or T
Flange F
Concealed “T” or ”Z“ MZ
Metal Pan MZ
(Verify compatibility/ consult
Pre Sales Technical Support.)
M O U N T I N G D A T A
L A M P C O N F I G U R A T I O N S
23-3/4"[603mm]
7/8" [22mm] K.O. (2)Access Plate7/8" [22mm]
48" [1217mm]7-7/8" [201mm]
4-5/8" [119mm]3" [77mm]
2 LAMP
4-3/4"[121mm]
2"[51mm]
23-3/4" [603mm]
10-3/16" [259mm]
2 LAMP – 12 CELL 3 LAMP – 18 CELL
4-3/4"[121mm]
2"[51mm]
23-3/4" [603mm]
7"[178mm]
7"[178mm]
3 LAMP 7/8" [22mm] K.O. (4)Access Plate7/8" [22mm] K.O.
48" [1217mm]7-7/8" [201mm]
4-5/8" [119mm]3" [77mm]
23-3/4"[603mm]
COOPER LIGHTING - METALUX®
![Page 2: 101719_2HP2GX_WO_232_2_3L_T8](https://reader036.fdocuments.net/reader036/viewer/2022081908/552c34374a79590e7d8b465b/html5/thumbnails/2.jpg)
Visit our web site at www.cooperlighting.comCustomer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 11/10 ADF101719
2 H P 2 G X T 8
Cande la
Angle Along II 45° Across⊥0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
1856 1856 1856
1828 1841 1856
1786 1811 1841
1729 1769 1819
1660 1717 1790
1580 1654 1750
1485 1579 1701
1381 1495 1642
1265 1399 1572
1140 1291 1479
1005 1167 1347
860 1023 1187
709 850 920
555 659 480
395 398 273
243 218 203
142 136 130
64 58 50
0 0 0
Coef f i c i en ts o f Ut i l i za t ion
Effective floor cavity reflectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0
1
2
3
4
5
6
7
8
9
10
P H O T O M E T R I C S
Zona l Lumen Summary
Zone Lumens %Lamp %Fixture
0-30
0-40
0-60
0-90
0-180
2HP2-WO-232W26P
Electronic Ballast
F32T8/835 lamps
2850 lumens.
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.4 x
mounting height.
Efficiency = 90.9%.
Test Report:
2HP2-WO-232W26P
LER = FP-83
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $2.89
1441 25.3 27.8
2381 41.8 45.9
4293 75.3 82.8
5184 90.9 100.0
5184 90.9 100.0
108 108 108 108 106 106 106 106 101 101 101 97 97 97 93 93 93 91
99 95 92 88 97 93 90 87 89 87 84 86 84 82 83 81 79 77
91 84 78 73 88 82 76 72 79 74 70 76 72 68 73 70 67 65
83 74 66 61 81 72 65 60 69 64 59 67 62 58 65 60 57 55
76 65 57 51 74 64 57 51 62 55 50 60 54 50 58 53 49 47
70 58 50 44 68 57 50 44 55 49 43 53 48 43 52 47 43 41
64 52 44 39 63 51 44 38 50 43 38 48 42 38 47 42 37 35
60 47 40 34 58 47 39 34 45 39 34 44 38 33 43 37 33 31
55 43 36 30 54 43 35 30 41 35 30 40 34 30 39 34 30 28
52 40 32 27 50 39 32 27 38 32 27 37 31 27 36 31 27 25
49 37 29 25 47 36 29 25 35 29 24 34 28 24 33 28 24 23
Luminance D at a
Average Average Average
Angle 0-Deg 45-Deg 90-Deg
In Deg cd/sm cd/sm cd/sm
45 2526 2860 3277
55 2349 2794 3242
65 2057 2443 1779
75 1471 1320 1229
85 1150 1043 899
![Page 3: 101719_2HP2GX_WO_232_2_3L_T8](https://reader036.fdocuments.net/reader036/viewer/2022081908/552c34374a79590e7d8b465b/html5/thumbnails/3.jpg)
Visit our web site at www.cooperlighting.comCustomer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 11/10 ADF101719
2 H P 2 G X - W O T 8
O R D E R I N G I N F O R M A T I O N
2HP2GAX-WO-228T8W26P 42 lbs.
2HP2GAX-WO-232W36P 42 lbs.
S H I P P I N G I N F O R M A T I O N
Catalog No. Wt.
Sample Number: 2HP2GX-WO-232W26P-UNV-HB81H-U
Ballast Type 6
HPT8 Ballast
HB8_L T8 Electronic Instant Start, Low Ballast Factor .77
=
HB8_ T8 Electronic Instant Start, Ballast Factor .88
=
HB8_N T8 Electronic Instant Start, Normal Ballast Factor 1.0
=
HB8_H T8 Electronic Instant Start, High Ballast Factor 1.15 ~ 1.2
=
HR8_DIM T8 Electronic Program Start Step Dimming Ballast Factor .88
=
HR8_L T8 Electronic Program Start, Low Ballast Factor .77
=
HR8_ T8 Electronic Program Start, Ballast Factor .88
=
HR8_H T8 Electronic Program Start, High Ballast Factor 1.15 ~ 1.2
=
Louver Finish
I Semi-Specular/Haze (Low Iridescent) (Silver Only)
=
P Painted White (Standard)
=
Rating
Blank Standard=
NY New York City Rated
=
ATW-SW4 Chicago Rated
=
Heat Removal
HR Heat Removal1=Option - Aluminum Flange Trim
4
Blank SW (Single White)
=
SN Single, Natural Finish=
RN In Row, Natural Finish
=
RW In Row, White Finish=
EN End of Row, Natural Finish
=
EW End of Row, White Finish
=
Width
2 2' Width=
Series
HP2 High Performance 2" Paralux Louver
Trim Type
G Grid/Lay-in - Standard
2=
T Concealed T / Slot Grid
3=
F Aluminum Flange Trim
4=
MZ Modular Trim=
Voltage 6
120V 120 Volt=
277V 277 Volt=
347V 347 Volt=
UNV Universal Voltage 120-277
7=
Number of Ballasts
1 1 Ballast=
2 2 Ballast=
3 3 Ballast=Air Supply
AX Air Supply Floating Louver
=
X Blank Side/Floating Louver - Non Air Supply
=
AVX Air Supply Floating Louver w/Directional Air Vane
=
Options
GL Single Element Fuse=
GM Double Element Fuse
=
WTR White Reveal=
Flex Flex Installed (Reference Flex ordering information)
=
EL Emergency Installed8=
Lamps Installed
Blank No Lamps Installed
=
L8835 T8 Lamp, 28W and 32W, 3500K
5=
L8841 T8 Lamp, 28W and 32W, 4100K
5=
L8835HL T8 Lamp, 32W 3500K, 3100 Lumens
=
L8841HL T8 Lamp, 32W 4100K, 3100 Lumens
=
Options
RIF1 Radio Interference Suppressor
=
20GA/REP 20 Gauge Riveted End Plates. For use in New York City.
=
RLS Rotor Lock Socket (T8 Lamp only)
=
Packaging
U Unit Pack=
PAL Job Pack, out of carton=
PALC Job Pack, in carton=
Number of Lamps
2 Lamps
3 Lamps
Wattage
28T8 28W T8 (48")5=
32 32W T8 (48")=
Louver Color
S Silver=
W White=
Cell Configuration
26 2 Rows of 6, 12 Cell (2'x4')
=
36 3 Rows of 6, 18 Cell (2'x4')
=
Notes: Integral End Plate Grid Lock feature not available in Heat Removal1
2 May also be used with Concealed T or Slot Grid T. Louver will be recessed by 5/16".
3 An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture.
4 Specify row configuration, type in catalog number when ordering complete fixtures.
5 When utilizing 28WT8 lamps, HPT8 Ballast must be specified.
6 Products also available in non-US voltage and frequencies for international markets
7 Not available when specifying emergencies, voltage must be specific
8 Fixtures equipped with "EL" option may require a 5-1/2" housing depth. If installing in field, must use low profile battery pack.
White OpticsWO 97% Reflective
White Optics Finish=
A C C E S S O R I E S
EQ-CLIP-U=T-BAR Safety
Earthquake Clips(3)