100W UV COB Flood - Silver Pines Sound & Light · 100W UV COB Flood User Manual 8 Setting the DMX...

12
Order code: LEDJ187 100W UV COB Flood User Manual

Transcript of 100W UV COB Flood - Silver Pines Sound & Light · 100W UV COB Flood User Manual 8 Setting the DMX...

Page 1: 100W UV COB Flood - Silver Pines Sound & Light · 100W UV COB Flood User Manual 8 Setting the DMX address: The DMX mode enables the use of a universal DMX controller. Each fixture

Order code: LEDJ187

100W UV COB Flood User Manual

Page 2: 100W UV COB Flood - Silver Pines Sound & Light · 100W UV COB Flood User Manual 8 Setting the DMX address: The DMX mode enables the use of a universal DMX controller. Each fixture

www.prolight.co.uk 100W UV COB Flood User Manual 2

Safety advice

WARNINGFOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP!• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.

• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.

• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessaryfortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.

• Pleasenotethatdamagescausedbyusermodificationstothisequipmentarenotsubjecttowarranty.

IMPORTANT:The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment.

OPERATING DETERMINATIONSIfthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageandthewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.

Donotendangeryourownsafetyandthesafetyofothers!

Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.

CAUTION!KEEP THIS EQUIPMENT AWAY FROM RAIN, MOISTURE AND LIQUIDS

CAUTION! TAKE CARE USING THIS EQUIPMENT!HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!!

• Neverletthepowercablecomeintocontactwithothercables.Handlethepowercableandallmainsvoltageconnectionswithparticularcaution!

• Neverremovewarningorinformativelabelsfromtheunit.

• Donotopentheequipmentanddonotmodifytheunit.

• Donotconnectthisequipmenttoadimmerpack.

• Donotswitchtheequipmentonandoffinshortintervals,asthiswillreducethesystem’slife.

• Onlyusetheequipmentindoors.

• Donotexposetoflammablesources,liquidsorgases.

• Alwaysdisconnectthepowerfromthemainswhenequipmentisnotinuseorbeforecleaning!Onlyhandlethepower-cablebytheplug.Neverpullouttheplugbypullingthepower-cable.

• Makesurethattheavailablemainssupplyvoltageisbetween100~240VAC,50/60Hz.

• Makesurethatthepowercableisnevercrimpedordamaged.Checktheequipmentandthepowercableperiodically.

• Iftheequipmentisdroppedordamaged,disconnectthemainspowersupplyimmediatelyandhaveaqualifiedengineerinspecttheequipmentbeforeoperatingagain.

• Iftheequipmenthasbeenexposedtodrastictemperaturefluctuation(e.g.aftertransportation),donotconnectpowerorswitchitonimmediately.Thearisingcondensationmightdamagetheequipment.Leavetheequipmentswitchedoffuntilithasreachedroomtemperature.

• Ifyourproductfailstofunctioncorrectly,stopuseimmediately.Packtheunitsecurely(preferablyintheoriginalpackingmaterial),andreturnittoyourProLightdealerforservice.

• Onlyusefusesofsametypeandrating.

• Repairs,servicingandpowerconnectionmustonlybecarriedoutbyaqualifiedtechnician.THISUNITCONTAINSNOUSERSERVICEABLEPARTS.

• Thislightingfixtureisforprofessionaluseonly-itisnotdesignedfororsuitableforhouseholduse.Theproductmustbeinstalledbyaqualifiedtechnicianinaccordancewithlocalterritoryregulations.Thesafetyoftheinstallationistheresponsibilityoftheinstaller.Thefixturepresentsrisksofsevereinjuryordeathduetofirehazards,electricshockandfalls.

• Warning!RiskGroup2LEDproductaccordingtoEN62471.Donotviewthelightoutputwithopticalinstrumentsoranydevicethatmayconcentratethebeam.

• WARRANTY:Oneyearfromdateofpurchase.

Page 3: 100W UV COB Flood - Silver Pines Sound & Light · 100W UV COB Flood User Manual 8 Setting the DMX address: The DMX mode enables the use of a universal DMX controller. Each fixture

www.prolight.co.uk 100W UV COB Flood User Manual 3

Product overview & technical specifications

FeaturingCOBtechnologythisrobustfloodisloadedwitha100WUVLEDwhichishousedina80°reflectorandsuppliedwiththreebeamreductionlenses(25°,40°and50°).ThisfixturehasbeendesignedtofillavarietyofvenueswithanoutstandingUVglowandiseasytotransportandinstall.ThehighoutputLEDisidealforwashingstages,nightclubs,bowlingcentresandskatingrinks.

100W UV COB Flood

257mm 245mm

310mm

•1x100WUVCOBLED

•Beamangle:80°native,25°,40°and50°beamreductionlensessupplied

•Ultravioletwavelength:400nm

•1.1kHzrefreshrate

•DMXchannels:1or2selectable

•Staticandsoundactivemodes

•0-100%dimmingandvariablestrobe

•Bracketallowsformultipleriggingandfloorstandingapplications

•4pushbuttonmenuwithLEDdisplay

•PowerCONinput/output

•3-PinXLRinput/output

•Fancooled

Specifications 100W UV COB Flood

Powerconsumption 105W

Powersupply 100~240V,50/60Hz

Fuse T2A250V

Dimensions 310x257x245mm

Weight 3.6kg

Ordercode LEDJ187

Page 4: 100W UV COB Flood - Silver Pines Sound & Light · 100W UV COB Flood User Manual 8 Setting the DMX address: The DMX mode enables the use of a universal DMX controller. Each fixture

www.prolight.co.uk 100W UV COB Flood User Manual 4

Technical specifications

01-Earthpoint

02-Safetyeye

03-LEDdisplay

04-Functionbuttons

05-3-PinDMXinput

06-3-PinDMXoutput

07-PowerCONinput

08-PowerCONoutput

09-FuseT2A250V

10-Hangingbracket

11-Hangingbracketadjustableknob

Inthebox:1 x fixture, 1 x 25° beam reduction lens, 1 x 40° beam reduction lens, 1 x 50° beam reduction lens, 1 x power cable & 1 x user manual

100W UV COB Flood

MENU

DMX INPUT

POWER INPUT:100-240V~50/60Hz

FUSE:T2A 250V

POWER OUTPUT:100-240V~50/60Hz

DMX OUTPUT

UPENTER DOWN

www.prolight.co.uk

10

05

11

07

0901 02

04

03

11

10

06

08

Page 5: 100W UV COB Flood - Silver Pines Sound & Light · 100W UV COB Flood User Manual 8 Setting the DMX address: The DMX mode enables the use of a universal DMX controller. Each fixture

www.prolight.co.uk 100W UV COB Flood User Manual 5

Operating instructions

MENU

S L A u Slave mode

d o n

d o n

d o F FDisplay backlight

S t n d

rEv Display inverse

d E F A Reset factory settings

S J - 1

S J - 8

Sound active/sound sensitivityS J - 5

U. 0 0 0

U. 2 5 5

F 5. 0 0

F 5. 1 5

Manual dimming modeU. 2 5 5

d. 0 0 1

d. 5 1 2

C h 0 1

C h 0 2

DMX address/channel settingd. 0 0 1

Page 6: 100W UV COB Flood - Silver Pines Sound & Light · 100W UV COB Flood User Manual 8 Setting the DMX address: The DMX mode enables the use of a universal DMX controller. Each fixture

www.prolight.co.uk 100W UV COB Flood User Manual 6

DMX mode:

OperatinginaDMXcontrolmodeenvironmentgivestheuserthegreatestflexibilitywhenitcomestocustomisingorcreatingashow.Inthismodeyouwillbeabletocontroleachindividualtraitofthefixtureandeachfixtureindependently.

ToaccesstheDMXaddressmode,pressthe“MENU”buttonontherearoftheunittoshowd.001ontheLEDdisplay.Nowusethe“UP”and“DOWN”buttonstosettherequiredDMXaddress.Pressthe“ENTER”buttontoconfirmthesetting. TheDMXchannelmodewillnowbedisplayed,usethe“UP”and“DOWN”buttonsontherearoftheunittoselecteither1or2DMXchannelmode.Pressthe“ENTER”buttontoconfirmthesetting.

Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

Master/slave mode:

Tosetthemasterunit,pressthe“MENU”buttonontherearofthemasterunitthenselectyourdesiredprogram(soundactiveordimmermodes).Tosettheotherunitsinslavemode,pressthe“MENU”buttonontherearoftheunittoshowSLAuontheLEDdisplayandpressthe“ENTER”buttontocon-firmthesetting.Theunitswillnowruninsequencewiththemasterunit.Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

PleaseensurethatallslaveunitsaresettothesameDMXchannelmodeasthemasterunit.

Manual dimming mode:

Toaccessthemanualdimmingmode,pressthe“MENU”buttonuntilthedisplayshowsU.255ontheLEDdisplay.Usethe“UP”and“DOWN”buttonstoselecttherequiredbrightnessfromU.000~U.255.Toadjusttheflashspeedpressthe“ENTER” buttonandthenusethe“UP”and“DOWN”but-tonstoselectanyvaluefromF5.00~F5.15.Pressthe“ENTER” buttontoconfirmthesetting.

Value: 000 - 255 (000 = low brightness, 255 = high brightness) Value: 00 - 15 (00 = no flash, 15 = fast flash speed)

Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

Operating instructions

Channel Value Function

1 000-255 Masterdimmer(0-100%)

2 000-015 Nofunction

016-255 Strobe(slow-fast)

2 channel mode:

Channel Value Function

1 000-255 Masterdimmer(0-100%)

1 channel mode:

Page 7: 100W UV COB Flood - Silver Pines Sound & Light · 100W UV COB Flood User Manual 8 Setting the DMX address: The DMX mode enables the use of a universal DMX controller. Each fixture

www.prolight.co.uk 100W UV COB Flood User Manual 7

Operating instructions

Sound active:

Toaccessthesoundactivemode,pressthe“MENU”buttonuntilthedisplayshowsSJ-5ontheLEDdisplay.Usethe“UP”and“DOWN”buttonstoselecttherequiredsoundsensitivityfromSJ-1~SJ-8.Pressthe“ENTER” buttontoconfirmthesetting.

Value: 1 - 8 (1 = low sensitivity, 8 = high sensitivity)

Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

Display backlight:

Toaccessthedisplaybacklightsetting,pressthe“MENU”buttonuntilthedisplayshowsdonontheLEDdisplay.Usethe“UP”and“DOWN”buttonstoselecteitherdon(displaybacklighton)~doff(displaybacklightoff).Pressthe“ENTER” buttontoconfirmthesetting.

Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

Display inverse:

Toaccessthedisplayinversesetting,pressthe“MENU”buttonuntilthedisplayshowsdonontheLEDdisplay.Pressthe“ENTER” buttontodisplayStndandusethe“UP”and“DOWN”buttonstoselecteitherStnd(displaystandard)~ (displayinverse).Pressthe“ENTER” buttontoconfirmthesetting.

Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

Reset factory settings:

Toresetthefactorysettings,pressthe“MENU”buttonuntilthedisplayshowsdonontheLEDdisplay.Pressthe“ENTER” buttontwicetodisplaydEFa.Pressthe“UP”and“DOWN”buttonstogetherandthefixturewillberesettoitsfactorysettings.

Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.rEv

Page 8: 100W UV COB Flood - Silver Pines Sound & Light · 100W UV COB Flood User Manual 8 Setting the DMX address: The DMX mode enables the use of a universal DMX controller. Each fixture

www.prolight.co.uk 100W UV COB Flood User Manual 8

Setting the DMX address:

TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachfixturerequiresa“startaddress”from1-511.Afixturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannelindicatedbythestartaddress.Forexample,afixturethatoccupiesoruses7channelsofDMXandwasaddressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthechainstartsat107.

DMX 512:

DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligentfixturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothefixture.DMXdataissentasserialdatathattravelsfromfixturetofixtureviatheDATA“IN”andDATA“OUT”XLRterminalslocatedonallDMXfixtures(mostcontrollersonlyhaveadata“out”terminal).

DMX linking:

DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogetherandoperatefromasinglecontroller,aslongasallfixturesandthecontrollerareDMXcompliant.ToensureproperDMXdatatransmission,whenusingseveralDMXfixturestrytousetheshortestcablepathpossible.TheorderinwhichfixturesareconnectedinaDMXlinedoesnotinfluencetheDMXaddressing.Forexample;afixtureassignedtoaDMXaddressof1maybeplacedanywhereinaDMXline,atthebeginning,attheend,oranywhereinthemiddle.WhenafixtureisassignedaDMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,nomatterwhereitislocatedintheDMXchain.

DATA cable (DMX cable) requirements (for DMX operation):

ThisfixturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,seeimagebelow.

Note: DMX cable must be daisy chained and cannot be split.

DMX setup

FurtherDMXcablescanbepurchasedfromallgoodsoundandlightingsuppliersorProLightConceptsdealers.Pleasequote:

CABL10 – 2mCABL11 – 5mCABL12 – 10m

Page 9: 100W UV COB Flood - Silver Pines Sound & Light · 100W UV COB Flood User Manual 8 Setting the DMX address: The DMX mode enables the use of a universal DMX controller. Each fixture

www.prolight.co.uk 100W UV COB Flood User Manual 9

Notice:

Besuretofollowthediagramsbelowwhenmakingyourowncables.DonotconnectthecablesshieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRsoutercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.

Special note:

Line termination:

Whenlongerrunsofcableareused,youmayneedtouseaterminatoronthelastunittoavoiderraticbehaviour.

Using a cable terminator will decrease the possibilities of erratic behaviour. (3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)

5-pin XLR DMX connectors:

Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRfixturesmaybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.

Terminationreducessignaltransmissionproblemsandinterference.ItisalwaysadvisabletoconnectaDMXterminal,(resistance120Ohm1/4W)betweenpin2(DMX-)andpin3(DMX+)ofthelastfixture.

5-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)Pin 4: N/CPin 5: N/C

3-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)

3-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)

5-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)Pin 4: N/CPin 5: N/C

DMX setup

Page 10: 100W UV COB Flood - Silver Pines Sound & Light · 100W UV COB Flood User Manual 8 Setting the DMX address: The DMX mode enables the use of a universal DMX controller. Each fixture

www.prolight.co.uk 100W UV COB Flood User Manual 10

WEEE notice

Correct Disposal of this Product (Waste Electrical & Electronic Equipment)

(Applicable in the European Union and other European countries with separate collection systems)

Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedwithotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtotheenvironmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromothertypesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.

Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheirlocalgovernmentoffice,fordetailsofwhereandhowtheycantakethisitemforenvironmentallysaferecycling.

Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthepurchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.

Page 11: 100W UV COB Flood - Silver Pines Sound & Light · 100W UV COB Flood User Manual 8 Setting the DMX address: The DMX mode enables the use of a universal DMX controller. Each fixture

www.prolight.co.uk 100W UV COB Flood User Manual 11

Page 12: 100W UV COB Flood - Silver Pines Sound & Light · 100W UV COB Flood User Manual 8 Setting the DMX address: The DMX mode enables the use of a universal DMX controller. Each fixture

www.prolight.co.uk 100W UV COB Flood User Manual 12