1 QXF heater parameters G. Chlachidze, M. Marchevsky March 13, 2014.

3
1 QXF heater parameters G. Chlachidze, M. Marchevsky March 13, 2014

Transcript of 1 QXF heater parameters G. Chlachidze, M. Marchevsky March 13, 2014.

Page 1: 1 QXF heater parameters G. Chlachidze, M. Marchevsky March 13, 2014.

1

QXF heater parameters

G. Chlachidze, M. MarchevskyMarch 13, 2014

Page 2: 1 QXF heater parameters G. Chlachidze, M. Marchevsky March 13, 2014.

2

Introduction

QXF protection heater (PH) design development currently in progress. Two major design options are under consideration:

stainless steel strips with heating stations, copper cladded stainless steel strips with or without heating

stations.

As a risk reduction PH of different design could be tested in first SQXF models.

We need to decide if strain gauge wiring could be included in the inner layer trace.

At last meeting we agreed to develop a list of basic electrical parameters of the heater circuit to be used in the heater design developments.

These parameters are developed for SQXF and LQXF coils and could be revisited in future for MQXF coils.

Page 3: 1 QXF heater parameters G. Chlachidze, M. Marchevsky March 13, 2014.

3

List of Heater Parameters

Peak power density: 50-100 W/cm2

HFU voltage: up to 450 V

HFU current: up to 220 A

HFU capacitance: 4.8-19.2 mF

Distance between heating stations: < 120 mm

Heating station width: 12-40 mm

Insulation thickness: 1 mil Kapton

Coil surface coverage: < 50% IL

???