Low Voltage Power Low Voltage Power Supplies for ALICESupplies for ALICE
TB 26.7.04TB 26.7.04L.JirdenL.Jirden
Recall: target devices & possible solutions
Outstanding actions
![Page 2: 1 Low Voltage Power Supplies for ALICE TB 26.7.04 L.Jirden u Recall: u target devices & possible solutions u Outstanding actions.](https://reader030.fdocuments.net/reader030/viewer/2022032804/56649e4c5503460f94b424eb/html5/thumbnails/2.jpg)
2
Target devicesTarget devices Wiener
PL500 F8: product exists; water cooling; some control limitations
PL500 F12: prototype exists; might not be commercialized
Marathon: Prototype exists; should replace F8, F12
Caen SY1527: product exist; no water cooling Easy prototype exist; B-field tolerant Sasy prototype exist; high B-field tolerant
Arem Pro Device H/W prototype exists; no water cooling
![Page 3: 1 Low Voltage Power Supplies for ALICE TB 26.7.04 L.Jirden u Recall: u target devices & possible solutions u Outstanding actions.](https://reader030.fdocuments.net/reader030/viewer/2022032804/56649e4c5503460f94b424eb/html5/thumbnails/3.jpg)
3
Wiener Marathon Wiener Marathon systemsystem
UX
CR
PFCAC/DC
Digitalcontrol
Power modules
230 VAC
CANbus
Water cooling
B-tol: 300 gaussRad tol: ?
DC/DCAnalogcontrol
Power modules
230 VAC CANbus
PFCAC/DC
Digitalcontrol
380 VDC
B-shield
B-tol: 1200 gaussRad tolerant
![Page 4: 1 Low Voltage Power Supplies for ALICE TB 26.7.04 L.Jirden u Recall: u target devices & possible solutions u Outstanding actions.](https://reader030.fdocuments.net/reader030/viewer/2022032804/56649e4c5503460f94b424eb/html5/thumbnails/4.jpg)
4
UX
CR
Caen Easy systemCaen Easy system
no cooling
230 VAC
CANbus
Powersupply
48 VDC
DC/DC DC/DC DC/DC
Digitalcontrol
Digitalcontrol
Digitalcontrol
SY1527main-frame
ethernet
Branchcontroller
EASY:B-tol: 1000 gauss
:Rad tol
B-tol: 50 gaussRad tol: ?
SASY: B-tol: 5000 gauss
: Rad tol
![Page 5: 1 Low Voltage Power Supplies for ALICE TB 26.7.04 L.Jirden u Recall: u target devices & possible solutions u Outstanding actions.](https://reader030.fdocuments.net/reader030/viewer/2022032804/56649e4c5503460f94b424eb/html5/thumbnails/5.jpg)
5
UX
CR
Arem Pro PSArem Pro PS
230 VAC RS232
AC/DCpower
AC/DCpower
AC/DCpower
modulecontrol
modulecontrol
cratecontrol
ethernet
B-tol: ? gaussRad tol: ?
no cooling
![Page 6: 1 Low Voltage Power Supplies for ALICE TB 26.7.04 L.Jirden u Recall: u target devices & possible solutions u Outstanding actions.](https://reader030.fdocuments.net/reader030/viewer/2022032804/56649e4c5503460f94b424eb/html5/thumbnails/6.jpg)
6
LVPS – possible LVPS – possible solutions Isolutions I
Detector
PS chan [no]
Target device Module [A]
Crates [no]
When require
d
Common purchase
SPD 20 Wiener Marathon 50 4 4Q05 Yes?
or 240 Caen Easy 9 4
SDD 216 Arem Pro ?? 6 6 4Q05 ?
SSD 448 Caen SY1527 ?? 3.6 5 ? ?
TPC 72 Wiener Marathon 50 22 4Q05 yes
TRD 180 Wiener Marathon 50? 45? 3Q05 yes
TOF ? Caen Sasy ? ? ? no
HMPID 100 Wiener Marathon 30? 14? 3Q05 Yes, commit before 05
![Page 7: 1 Low Voltage Power Supplies for ALICE TB 26.7.04 L.Jirden u Recall: u target devices & possible solutions u Outstanding actions.](https://reader030.fdocuments.net/reader030/viewer/2022032804/56649e4c5503460f94b424eb/html5/thumbnails/7.jpg)
7
LVPS possible LVPS possible solutions IIsolutions II
Detector
PS chan [no]
Target device Module [A]
Crates [no]
When require
d
Common purchase
PHOS &CPV
11 Wiener Marathon 20 – 115?
5? ? yes
FMD ? ? ? ? ? ?
T0 4 Caen Easy ? 1 ? yes
V0 ? Caen Easy ? 1 ? ?
PMD ? Wiener Marathon ? ? ? yes
ZDC ? ? ? ? ? ?
MTK 364 Wiener Marathon 25? 31? 2Q05 yes
MTG 16 Wiener Marathon 115? 2? 4Q04 yes
TOTAL 1461 + ?
3 manufacturers -5 types
3.6 - 250
136 + ?
4Q04- 4Q05
9 yes; 5 ?; 1 no
![Page 8: 1 Low Voltage Power Supplies for ALICE TB 26.7.04 L.Jirden u Recall: u target devices & possible solutions u Outstanding actions.](https://reader030.fdocuments.net/reader030/viewer/2022032804/56649e4c5503460f94b424eb/html5/thumbnails/8.jpg)
8
Outstanding actionsOutstanding actions
Send out market survey: end June done
Finalize ALICE requirements: before mid August Electrical characteristics: as drafted unless protests Suggested size of modules: 10A, 30A, 50A,
with possibility to operate modules in parallel to at least 250A control functions:
Remote voltage control: ? Grouping: yes (if not too expensive) Remote power on/off: yes (if not too expensive)
Radiation policy: TC 30 August 04 Issue the tender: early September
Finalize technical spec: Merge ALICE requirements with other experiments Final draft to detectors end August for ok
Send out tender
![Page 9: 1 Low Voltage Power Supplies for ALICE TB 26.7.04 L.Jirden u Recall: u target devices & possible solutions u Outstanding actions.](https://reader030.fdocuments.net/reader030/viewer/2022032804/56649e4c5503460f94b424eb/html5/thumbnails/9.jpg)
9
![Page 10: 1 Low Voltage Power Supplies for ALICE TB 26.7.04 L.Jirden u Recall: u target devices & possible solutions u Outstanding actions.](https://reader030.fdocuments.net/reader030/viewer/2022032804/56649e4c5503460f94b424eb/html5/thumbnails/10.jpg)
10
Detector Detector requirementsrequirements
Quantities ALICE total ~160 LVPS crates and ~2000 PS
channels
Draft technical specification (Spec) Electrical characteristics Mechanical characteristics Monitoring and control Cooling Environment Standard chapters on:
construction, safety, reliability, quality assurance, documentation
![Page 11: 1 Low Voltage Power Supplies for ALICE TB 26.7.04 L.Jirden u Recall: u target devices & possible solutions u Outstanding actions.](https://reader030.fdocuments.net/reader030/viewer/2022032804/56649e4c5503460f94b424eb/html5/thumbnails/11.jpg)
11
Spec:Spec:Electrical Electrical
CharacteristicsCharacteristics DC Output
Modular design; 2 – 7 V, 4 – 250 A modules
LVPS 2 – 7 V, 4A
LVPS 2 – 7 V, 250A
24h stability < 5mV or 0.1%
6m stability < 20mV or 0.5%
Noise & ripple < 10mV p to p
![Page 12: 1 Low Voltage Power Supplies for ALICE TB 26.7.04 L.Jirden u Recall: u target devices & possible solutions u Outstanding actions.](https://reader030.fdocuments.net/reader030/viewer/2022032804/56649e4c5503460f94b424eb/html5/thumbnails/12.jpg)
12
Spec:Spec:Mechanical Mechanical
CharacteristicsCharacteristicsTYPICAL RACK LAYOUT
4U
1U
max 6U
1U
max 6U
VENTILATOR & CONTR.
HEAT EXCHANGER
LV PS
LV PS
HEAT EXCHANGER
LV PS
FRONT VIEW
LV PS
LV PS
SPACE
FOR
CABLES
600 mm300 mm
SIDE VIEW
![Page 13: 1 Low Voltage Power Supplies for ALICE TB 26.7.04 L.Jirden u Recall: u target devices & possible solutions u Outstanding actions.](https://reader030.fdocuments.net/reader030/viewer/2022032804/56649e4c5503460f94b424eb/html5/thumbnails/13.jpg)
13
Spec:Spec:Monitoring & ControlMonitoring & Control
LVPS 1LOCAL PANEL
Ethernet
CANbus
Provided by manufacturer
External interlock
OPC Server
PC
OPC Server
PC
PCI “Kvaser”
Two options:a) Via CANbus b) Via Ethernet
LVPS 1LOCAL PANEL
![Page 14: 1 Low Voltage Power Supplies for ALICE TB 26.7.04 L.Jirden u Recall: u target devices & possible solutions u Outstanding actions.](https://reader030.fdocuments.net/reader030/viewer/2022032804/56649e4c5503460f94b424eb/html5/thumbnails/14.jpg)
14
Spec: MONITORING AND Spec: MONITORING AND CONTROL FUNCTIONSCONTROL FUNCTIONS
VOLTAGES MON CON Individual channels ESS
CURRENTS MON 12 bit resolution ESS
RAMPING RATE MON CON Individual channels DES
TEMPERATURE MON Sensor above power circuits
ESS
OVER-CURRENT TRIP OFF VALUE
MON CON Individual channels ESS
FAN STATUS MON Out of limit warning ESS
OVER-VOLTAGE STATUS MON Individual channels DES
OVER-CURRENT STATUS MON Individual channels ESS
OVER-TEMP MON Out of limit warning ESS
MON = MONITOR
CON = CONTROL
ESS = ESSENTIAL
DES = DESIREDFUNCTIONS/PARAM
![Page 15: 1 Low Voltage Power Supplies for ALICE TB 26.7.04 L.Jirden u Recall: u target devices & possible solutions u Outstanding actions.](https://reader030.fdocuments.net/reader030/viewer/2022032804/56649e4c5503460f94b424eb/html5/thumbnails/15.jpg)
15
Spec: MONITORING AND Spec: MONITORING AND CONTROL FUNCTIONSCONTROL FUNCTIONS
DC TRIP OFF MON Individual channelsGlobal DC power
ESSESS
RESET DC TRIP OFF CON Individual channelsGlobal DC power
ESSESS
DC POWER ON/OFF MON CON Individual channelsGlobal DC power
ESSESS
AC POWER ON/OFF MON CON using external power DES
PS HEALTH MON Summary status DES
LOCAL CONTROL MON Remote control locked out ESS
PS RESET CON System reset (tbs)?? ESS
MON = MONITOR
CON = CONTROL
ESS = ESSENTIAL
DES = DESIREDFUNCTIONS/PARAM
![Page 16: 1 Low Voltage Power Supplies for ALICE TB 26.7.04 L.Jirden u Recall: u target devices & possible solutions u Outstanding actions.](https://reader030.fdocuments.net/reader030/viewer/2022032804/56649e4c5503460f94b424eb/html5/thumbnails/16.jpg)
16
VOLTAGES CON Groups of channels DES
DC POWER ON/OFF CON Groups of channels DES
RAMPING RATE MON CON Groups of channels DES
OVER-CURRENT TRIP OFF VALUE
MON CON Groups of channels ESS
MON = MONITOR
CON = CONTROL
ESS = ESSENTIAL
DES = DESIREDFUNCTIONS/PARAM
GROUP MANAGEMENT:THE POSSIBILITY TO CONFIGURE AND PERFORM FUNCTIONS ON GROUPS OF CHANNELS WITHIN A CRATE
Spec: MONITORING Spec: MONITORING AND CONTROL AND CONTROL
FUNCTIONSFUNCTIONS
![Page 17: 1 Low Voltage Power Supplies for ALICE TB 26.7.04 L.Jirden u Recall: u target devices & possible solutions u Outstanding actions.](https://reader030.fdocuments.net/reader030/viewer/2022032804/56649e4c5503460f94b424eb/html5/thumbnails/17.jpg)
17
Spec: OPC SERVERSpec: OPC SERVER
General Compliance with OPC standards No effect on PS output due to failure of remote
control Restart of OPC remotely Not send set points automatically at startup –
read from device PS shall maintain its set points during PS
power failure Genuine device and cache access Interactive list of device functions
![Page 18: 1 Low Voltage Power Supplies for ALICE TB 26.7.04 L.Jirden u Recall: u target devices & possible solutions u Outstanding actions.](https://reader030.fdocuments.net/reader030/viewer/2022032804/56649e4c5503460f94b424eb/html5/thumbnails/18.jpg)
18
Maintenance To support future versions of Windows and
OPC standards To support future versions of PS firmware
Configuration Allow appropriate management of the fieldbus Human readable configuration file (such as
XML) Obtain actual configuration by scanning Setting of ranges for analog values and setting
of the dead band
Spec: OPC SERVERSpec: OPC SERVER
![Page 19: 1 Low Voltage Power Supplies for ALICE TB 26.7.04 L.Jirden u Recall: u target devices & possible solutions u Outstanding actions.](https://reader030.fdocuments.net/reader030/viewer/2022032804/56649e4c5503460f94b424eb/html5/thumbnails/19.jpg)
19
Performance Change in Device to OPC:max 10 sec at full bus load
max 1 sec for a single PS
Device cache to OPC client: max 3 sec for all parameters
Write from OPC to device: max 1 sec Interlock to start ramp-down: max 5 ms
Spec: OPC SERVERSpec: OPC SERVER
![Page 20: 1 Low Voltage Power Supplies for ALICE TB 26.7.04 L.Jirden u Recall: u target devices & possible solutions u Outstanding actions.](https://reader030.fdocuments.net/reader030/viewer/2022032804/56649e4c5503460f94b424eb/html5/thumbnails/20.jpg)
20
Spec: cooling, etc.Spec: cooling, etc.
Cooling Use of standard ventilators not possible due to stray magnetic
fields Water cooling recommended Installed in rack with assured vertical airflow removing max
3kW/rack Environment
Radiation Total dose: 10 mGy Fluency: 109 n/cm2
Magnetic Field up to 200 Gauss Construction
Halogen free material Safety regulations
CE certification Reliability
MTBF > 90 000 hours (excluding ventilators)
![Page 21: 1 Low Voltage Power Supplies for ALICE TB 26.7.04 L.Jirden u Recall: u target devices & possible solutions u Outstanding actions.](https://reader030.fdocuments.net/reader030/viewer/2022032804/56649e4c5503460f94b424eb/html5/thumbnails/21.jpg)
21
Spec: QA, Spec: QA, documentationdocumentation
Quality assurance Production tests
Functional tests Load tests
Documentation User’s guide Reference manual Test and calibration reports