ZXG10-BTS(V2)ZXG10-BTS(V2)System ArchitecSystem Architec
tureture
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
OBJECTIVESOBJECTIVES
• To know the system capacity of ZXG10- Base Tranceiver Station Version 2
• To understand the parts and functions of the ZXG10-BTS V2
• To discover important features and technologies of ZXG10 BTS V2
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
BTS
BSC
MSC
VLR HLR AuC EIR
PSTN,ISDN...
OMCOMC
NMC X.25 linksGSM interfaces
Voicemail Server
SM-SC
MS (Mobile Station)
BSS (Base Station System)
NSS (Network Switching Subsystem)
OMM (Operations & Maintenance Management)
MS
GENERAL NETWORK ARCHITECTURE
GSM SYSTEMGSM SYSTEM
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
ZXG10 BSS STRUCTUREZXG10 BSS STRUCTURE
BTSBIE
BIE
BTS SM SM TC
BSC
MSC
OMC-RMS
Um
Abis Q3
BS Interface
Ater A
SGSNGb
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
BTS HARDWARE PRINCIPLEBTS HARDWARE PRINCIPLE
BSC
O
M
U
B
P
U
R
F
U
A
P
U
P D U
Abis Interface
Data Link
System Clock
System Clock
Control signal
Demodulated Signal
ModulatedSignal
RFSignal
Um Interface
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
BTS HARDWARE CONFIGURATIONBTS HARDWARE CONFIGURATION
BSC
CMM
PDM
FCM
TRM 1
TRM 6
TRM 12
.
.
.
.
.
.
.
.
AEM
Abis
MMIUm
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
BTS HARDWARE CONFIGURATIONBTS HARDWARE CONFIGURATION
1. CMM:Controller & Maintenance Module
2. TRM:Transceiver Module
3. AEM:Antenna Equipment Module
4. FCM:Fan Control Module
5. PDM:Power Distribute Module
MAIN MODULES OF ZXG10 –BTS V.2
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
BTS HARDWARE CONFIGURATIONBTS HARDWARE CONFIGURATION
TPU Tranceiver Processing UnitRCU Radio Carrier UnitPAU Power Amplifier UnitCDU Combiner Distribution UnitRDU Receiver Distribution UnitCEU Combiner Extension Unit
CONTROLLER AND MAINTENANCE MODULE
TRM
AEM
FAN CONTROL MODULE
POWER DISTRIBUTION MODULE
MAIN MODULES OF ZXG10 –BTS V.2
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
BTS HARDWARE CONFIGURATIONBTS HARDWARE CONFIGURATION
PDM CMM
CMMFCM
FCM
FCM
CDU
CDU
CDU
CDU
CDU
CDU
TRM
TRM
TRM
TRM
TRM
TRM
TRM
TRM
TRM
TRM
TRM
TRM
PDM CMM
CMMFCM
FCM
FCM
CDU
CDU
CDU
CDU
CDU
CDU
STRG
SPAG
STRG
STRG
SPAG
SPAG
STRG
STRG
SPAG
STRG
SPAG
SPAG
Single Rack Figure
40 W 80 W
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
BTS HARDWARE CONFIGURATION BTS HARDWARE CONFIGURATION EXPANSIONEXPANSION
S444 S888 S12/12/12
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
BTS HARDWARE CONFIGURATION BTS HARDWARE CONFIGURATION EXPANSIONEXPANSION
风机层
CMM
CMMPDM
CDU
CDU
TRM
TRM
TRM
TRM
CDU
CDU
TRM
TRM
TRM
TRM
风机层
CDU
CDU
TRM
TRM
TRM
TRM
风机层FCM
FCM
FCM风机层
CMM
CMMPDM
CDU
CDU
TRM
TRM
TRM
TRM
CDU
CDU
TRM
TRM
TRM
TRM
风机层
CDU
CDU
TRM
TRM
TRM
TRM
风机层FCM
FCM
FCM风机层
CMM
CMMPDM
CDU
CDU
TRM
TRM
TRM
TRM
CDU
CDU
TRM
TRM
TRM
TRM
风机层
CDU
CDU
TRM
TRM
TRM
TRM
风机层FCM
FCM
FCM
BTS#1BTS#3 BTS#2
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
CMM HARDWARECMM HARDWARE
Indicator Light Test Reset
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
CMM MODULE FUNCTIONSCMM MODULE FUNCTIONS
1. BS interface functions
2. Providing various clocks needed by BS
3. Remote operation & maintenance function of BTS
4. Local operation & maintenance functions of BTS
5. Equipment alarm collection
6. Active/standby hot backup
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
CMM MODULE STRUCTURECMM MODULE STRUCTURE
Relay array
Line interface
Sw
itching unit
BS
interface
Clock unit
Environmentmonitoring unit
Main
controllerunit
Master/slaveinterface unit
MMI unit
Power supplyunit
CLKCLK-ref
BS interface unit
Abis TO TRM
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
EXTERNAL INTERFACES OF CMM (1)EXTERNAL INTERFACES OF CMM (1)
• Abis interface• Data/clock interface between the rack at the same site• Data/clock interface inside a rack (from CMM to TRM)• Test interfaces • Panel interface
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
EXTERNAL INTERFACES OF CMM (2)EXTERNAL INTERFACES OF CMM (2)
• External environment monitoring interface
• Active/standby interfaces
• MMI
• Power interface
• Site ID collection interface
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
DIPSWITCH OF CMM (1)DIPSWITCH OF CMM (1)
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
INDOOR SYN CHANEL_NO BTS_NO SLAVE1_PORT SLAVE2_PORT SATE ABIS_PORT ABIS_TS
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
DIPSWITCH OF CMM (1)DIPSWITCH OF CMM (1)
INDOOR: type of BTS (0-indoors, 1-outdoors)
SYN: Network synchronization reference clock source (0-clock extracted from the E1 interface, 1-SDH synchronization clock)
CHANEL_NO: selection of on-site monitoring equipment ports (00-RS232 interface used to connect the transparent path, 01-RS422 interface used to connect the transparent path, 10-RS232 interface used to connect the main control unit)
BTS_NO: rack No. in the same site (00-master rack, 01-slave rack 1, 10-slave rack 2)
SLAVE1_PORT: master rack E1 port used to connect slave rack 1 (00-master rack C port, 01-master rack D port, 10-master rack E port, 11-master rack F port)
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
DIPSWITCH OF CMM (2)DIPSWITCH OF CMM (2)
SLAVE2_PORT: master rack E1 port used to connect slave rack 2 (00-master rack C port, 01-master rack D port, 10-master rack E port, 11-master rack F port)
SATE: whether to use the satellite Abis link (0 indicates the ordinary Abis, and 1 indicates the satellite Abis)ABIS_PORT: O&M port No. (00-port A, 01-port B, 10-port C, 11-port D)ABIS_TS: O&M LapD timeslots on Abis interfaces (000-Ts16, 001-Ts31, 010-Ts30, 011-Ts29, 100-Ts28, 101-Ts27, 110-Ts26, 111-Ts25);
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
TRM INTRODUCTION (1)TRM INTRODUCTION (1)
TRM
TX
RX
RXDRST
发射
接收
分集接收
把手
指示灯
复位
Indicator light
Receiver
Transmitter
Reset
handle
Diversity Receiver
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
TRANCEIVER MODULE 40W and 80WTRANCEIVER MODULE 40W and 80W
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
TRM INTRODUCTION (2)TRM INTRODUCTION (2)
RCU
PAU
AEMTPU
Uplink Signal
Check Signal
Downlink Signal
Antenna
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
TRM PANEL DESCRIPTIONTRM PANEL DESCRIPTION
Category Working band Name Description GSM900 or EGSM900 TRMG It works in GSM900 or
EGSM900 band
GSM1800 TRMD It works in GSM1800 band
STRG It works in GSM900 or EGSM900 band
SPAG It works in GSM900 band
STRDSPAD
It works in GSM1800 bandGSM1800
TRM (40W)
TRM (80W) GSM900 or EGSM900
TRM (80W)
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
ANTENNA EQUIPMENT MODULE (AEM)ANTENNA EQUIPMENT MODULE (AEM)
TRM GROUP AEM
Tx
Rx
RxD
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
ANTENNA EQUIPMENT MODULE TYPESANTENNA EQUIPMENT MODULE TYPES
• Combiner Distribution Unit (CDU) • “D” Combiner Distribution Unit (DCDU)• “E” Combiner Distribution Unit (ECDU)• Combiner Extension Unit (CEU) • Receiver Distribute Unit (RDU)
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
INTRODUCTION OF CDU (1)INTRODUCTION OF CDU (1)
VSWR_meter
ANT
RTEforward reverse
Alarms
optional
DuplexerCable
Cable
Rx_in
Tx_out
RX1RX2
RX3RX4
ERX1ERX2
LNA_Splitter
Alarms
TX1
TX250ohm
Hybird_combiner
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
INTRODUCTION OF CDU (2)INTRODUCTION OF CDU (2)
1 to 4 Divider
2 to 1 Combiner
DUPLEXER
CDU (Combiner Distribution Unit)
Ext Receive
RX1
CDU
TEST
ANT
TX1TX2
RX2
RX3
RX4
EX1
EX2
Combiner Input
Indicator
Divider Output
Divider Ext Output
Antenna
Test Port
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
INTRODUCTION OF DCDUINTRODUCTION OF DCDU
VSWR_meter
ANT
RTEforward reverse
Alarms
optional
DuplexerCable
Cable
Rx_in
RX1
RX2
LNA_Splitter
Alarms
ITX
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
INTRODUCTION OF ECDUINTRODUCTION OF ECDU
VSWR_meter
ANT
RTEforward reverse
Alarms
optional
Duplexer Cable
Cable
Rx_in RX1
RX2
LNA_Splitter
Alarms
ITX
Rx_filterANTD Cable Rx_inLNA_Splitter
Alarms
RXD1
RXD2
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
INTRODUCTION OF RDU (1)INTRODUCTION OF RDU (1)
RTE
Rx_filter
50ohm
ANT Cable Rx_in RX1RX2RX3RX4
ERX1ERX2
LNA_Splitter
Alarms
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
INTRODUCTION OF RDU (2)INTRODUCTION OF RDU (2)
1 to 4 Divider
RDU (Receiver Distribution Unit)
Ext Receive
RX1
RDU
ANT
RX2RX3RX4EX1EX2
Divider Output
Divider Ext Output
Antenna
Indicator
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
INTRODUCTION OF CEU (1)INTRODUCTION OF CEU (1)
To CDU TX1
RX1RX2RX3RX4
ERX1
ERX2
Rx_Splitter
TX1
TX250ohm
Hybird_combiner
To CDU TX2 TX3TX450ohm
Hybird_combiner
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
INTRODUCTION OF CEU (2)INTRODUCTION OF CEU (2)CEU (Combiner Extension Unit)
1 to 2 Divider
2 to 1 Combiner
1 to 2 Divider
2 to 1 CombinerRX1
CEUTX1
TX2
RX2RX3RX4EX1EX2
OTX1
TX3
TX4
OTX2
Indicator
Divider Output
Divider Ext Output
Combiner Input
Combiner Output
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
ZXG10-BTS V.2 AEM CONFIGURATIONZXG10-BTS V.2 AEM CONFIGURATION
Sum of Carrier
(one cell)
Sum of
CDU
Sum Of
CEU
1 2 02 2 03 2 04 2 05 2 16 2 1
Sum of Carrier
(one cell)
Sum of
CDU
Sum of
CEU
7 2 28 2 29 4 110 4 111 4 212 4 2
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
ZXG10-BTS V.2 BASIC CONFIGURATIONZXG10-BTS V.2 BASIC CONFIGURATION
TX/RX TX/RX
TRM1TX RX RXD
TRM2TX RX RXD
TRM4TX RX RXD
CDUTX1 TX2 RX1 RX2 RX3 RX4
CDUTX1 TX2 RX1 RX2 RX3 RX4
TRM3TX RX RXD
O4
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
ZXG10-BTS V.2 BASIC CONFIGURATIONZXG10-BTS V.2 BASIC CONFIGURATION
TX/RX TX/RX
TRM6TX RX RXD
CDUTX1 TX2
RX1RX2RX3RX4EX2EX1
CEUTX1 TX2 RX1 RX2 RX3 RX4TX3 TX4
OTX1 OTX1 EX1 EX2 CEUTX1 TX2 RX1 RX2 RX3 RX4TX3 TX4
OTX1 OTX1 EX1 EX2
TRM8TX RX RXD
TRM7TX RX RXD
TRM5TX RX RXD
TRM2TX RX RXD
TRM1TX RX RXD
TRM4TX RX RXD
TRM3TX RX RXD
CDUTX1 TX2 EX2EX1
RX1RX2RX3RX4
O8
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
ZXG10-BTS V.2 BASIC CONFIGURATIONZXG10-BTS V.2 BASIC CONFIGURATION
O10
TX1TX2RX1RX2RX3RX4EX1EX2
TX1TX2RX1RX2RX3RX4EX1EX2
TX1TX2RX1RX2RX3RX4EX1EX2
TX1TX2
RX1RX2RX3RX4
EX1EX2
TX4TX3
OTX1OTX2
TX1TX2
RX1RX2RX3RX4
EX1EX2
TX4TX3
OTX1OTX2
CDU
CDU
CDU
CEU
CEU
TRM1 RXRXDTX
TRM2 RXRXDTX
TRM3 RXRXDTX
TRM4 RXRXDTX
TRM5 RXRXDTX
TRM6 RXRXDTX
TRM7 RXRXDTX
TRM8 RXRXDTX
TX/RX
TX/RX
TX/RX
RX1RX2RX3RX4EX1EX2
RDU
TX/RX
Notes: use two pairs of polarized antenna
TRM9 RXRXDTX
TRM10 RXRXDTX
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
ZXG10-BTS V.2 BASIC CONFIGURATIONZXG10-BTS V.2 BASIC CONFIGURATION
TX1TX2RX1RX2RX3RX4EX1EX2
TX1TX2RX1RX2RX3RX4EX1EX2
TX1TX2RX1RX2RX3RX4EX1EX2
TX1TX2
RX1RX2RX3RX4
EX1EX2
TX4TX3
OTX1OTX2
TX1TX2
RX1RX2RX3RX4
EX1EX2
TX4TX3
OTX1OTX2
CDU
CDU
CDU
CEU
CEU
TRM1 RXRXDTX
TRM2 RXRXDTX
TRM3 RXRXDTX
TRM4 RXRXDTX
TRM5 RXRXDTX
TRM6 RXRXDTX
TRM7 RXRXDTX
TRM8 RXRXDTX
TRM9 RXRXDTX
TRM10 RXRXDTX
TRM11 RXRXDTX
TRM12 RXRXDTX
TX/ RX
TX/ RX
TX/ RX
TX1TX2RX1RX2RX3RX4EX1EX2
CDU
TX/ RX
注 : 天 线 为 两 副 极 化 天 线
O12
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
FAN CONTROL MODULE FUNCTIONSFAN CONTROL MODULE FUNCTIONS
• Temperature monitoring
• Fan control and inspection
• Communication with TRM
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
FAN CONTROL MODULE FUNCTIONSFAN CONTROL MODULE FUNCTIONS
CPU
Optical coupling isolation
Monitoringcircuit
Fan drive
Power supply 1
PWM Fan control
Temperature 1
Temperature 2
Fan 1 rotation speed
Fan 2 rotation speed
From TRM
Temperature 1 alarm
Temperature 2 alarm
Fan alarm
CPU alarm
+12V
+5VPower supply 2
From RRM
-48V or +24V
Optical coupling isolation
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
PDM POWER SUPPLY MODULEPDM POWER SUPPLY MODULE
PDM
FCM
Backplane of the carrier shelf
CMMbackplane
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
BTS V.2 POWER CONSUMPTIONBTS V.2 POWER CONSUMPTION
TRM: 140W
AEM: 70W
CMM(2): 20W
Fans and others: 80W
One frame when full configuration: 700W
One rack when full configuration< 2200W
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
TOP CONFIGURATIONTOP CONFIGURATION
1110987654
15
17
18
19
16
31 2
13
14
12
1: PE 2: PWRTA_L1 3: PWRTA_L2 4: PWRTA_L3 5: 13MHz 6: FCLK 7: RS2328: E1 PORT 9: RELAY_ALM 10: ID PORT 11: SYNC 12: HYCOM3 13: HYCOM214: HYCOM1 15: GND 16: HYCOM6 17: PWR 18: HYCOM5 19: HYCOM4
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
INTERFACE AND COMMUNICATIONINTERFACE AND COMMUNICATION
External Monitoring
System
BSC
Tower Mounted Amplifier
M Interface
Abis Interface
MMI Interface
Um Interface
B Interface
Interface of the tower amplifier system
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
FRAME STRUCTURE OF Abis INTERFACEFRAME STRUCTURE OF Abis INTERFACE1 : 1 multiplexing
SYNC : Synchronous time slot
TRX : LAPD signaling channel of radio carrier
OMU : LAPD channel of OMU, mainly includes configuration and O&M information of all BTSs
TCH : Traffic channel, occupying 2 bits, 16kb/s
TS 0 1 2 3 4 5 6 70 SYNC1 TRX12 TCH0 TCH1 TCH2 TCH33 TCH4 TCH5 TCH6 TCH74 TRX25 TCH0 TCH1 TCH2 TCH36 TCH4 TCH5 TCH6 TCH77 TRX38 TCH0 TCH1 TCH2 TCH39 TCH4 TCH5 TCH6 TCH7
10 TRX411 TCH0 TCH1 TCH2 TCH312 TCH4 TCH5 TCH6 TCH713 TRX514 TCH0 TCH1 TCH2 TCH315 TCH4 TCH5 TCH6 TCH716 O+M117 TRX618 TCH0 TCH1 TCH2 TCH319 TCH4 TCH5 TCH6 TCH720 TRX721 TCH0 TCH1 TCH2 TCH322 TCH4 TCH5 TCH6 TCH723 TRX824 TCH0 TCH1 TCH2 TCH325 TCH4 TCH5 TCH6 TCH726 TRX927 TCH0 TCH1 TCH2 TCH328 TCH4 TCH5 TCH6 TCH729 O+M430 O+M331 O+M2
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
FRAME STRUCTURE OF Abis INTERFACEFRAME STRUCTURE OF Abis INTERFACE1 : 4 multiplexing
TS 0 1 2 3 4 5 6 70 SYNC1 TRX1 TRX2 TRX3 TRX42 TCH0 TCH1 TCH2 TCH33 TCH4 TCH5 TCH6 TCH74 TCH0 TCH1 TCH2 TCH35 TCH4 TCH5 TCH6 TCH76 TCH0 TCH1 TCH2 TCH37 TCH4 TCH5 TCH6 TCH78 TCH0 TCH1 TCH2 TCH39 TCH4 TCH5 TCH6 TCH7
10 TRX5 TRX6 TRX7 TRX811 TCH0 TCH1 TCH2 TCH312 TCH4 TCH5 TCH6 TCH713 TCH0 TCH1 TCH2 TCH314 TCH4 TCH5 TCH6 TCH715 TCH0 TCH1 TCH2 TCH316 O+M17 TCH4 TCH5 TCH6 TCH718 TCH0 TCH1 TCH2 TCH319 TCH4 TCH5 TCH6 TCH720 TRX9 TRX10 TRX11 TRX1221 TCH0 TCH1 TCH2 TCH322 TCH4 TCH5 TCH6 TCH723 TCH0 TCH1 TCH2 TCH324 TCH4 TCH5 TCH6 TCH725 TCH0 TCH1 TCH2 TCH326 TCH4 TCH5 TCH6 TCH727 TCH0 TCH1 TCH2 TCH328 TCH4 TCH5 TCH6 TCH729 O+M430 O+M331 O+M2
SYNC : Synchronous time slot
TRX : LAPD signaling channel of radio carrier
OMU : LAPD channel of OMU, mainly includes configuration and O&M information of all BTSs
TCH : Traffic channel, occupying 2 bits, 16kb/s
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
ZXG10 – BTS VERSION 2 NETWORKZXG10 – BTS VERSION 2 NETWORK
The star networking mode
BSC.
.
.
Site 0
Site 1
Site n
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
ZXG10 – BTS VERSION 2 NETWORKZXG10 – BTS VERSION 2 NETWORK
Schematic diagram of chain networking
BSC
Site 0 Site 1 Site 2
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
ZXG10 – BTS VERSION 2 NETWORKZXG10 – BTS VERSION 2 NETWORK
Tree Networking Mode
BSC Site 0
Site 1
Site 2
Site n
Site 3
.
.
.
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
ZXG10-BTS (V2) INTERNETWORKINGZXG10-BTS (V2) INTERNETWORKING
BTS
MSC BSC
BTS
BTS
BTS
BTS
BTS
BTS
BTS
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
ZXG10-BTS (V2) LINK PROTECTIONZXG10-BTS (V2) LINK PROTECTION
BTS BTS BTS
A
B
A
B
C
D
A
BBSC
High reliability key components adopt redundancy and backup technology Adopt the BCCH carrier automatically rearranging technology to
improve the system reliable BTS support the automatic skip connection protection function for link-
connection mode
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
SHELTER BTSSHELTER BTS
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
SHELTER BTS SPECIFICATIONSSHELTER BTS SPECIFICATIONS
• The ZXG10 SBTS normally holds the ZXG10-BTS(V2) rack and matched device, so the ZXG10 SBTS supports all the features of the ZXG10-BTS(V2).
• It can hold 1, 2 or 3 ZXG10-BTS(V2) racks respectively. The largest capacity is 36 TRXs. The shelter of the ZXG10 SBTS can also contain the ZXG10-BSC and the ZXG10-BTS(V2) simultaneously.
• Standard configuration consists of two accumulator sets with a total capacity of 400 AH (Max. 800AH). This configuration ensures a power supply of 4~8 hours.
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
SHELTER BTS SPECIFICATIONSSHELTER BTS SPECIFICATIONS
•The ZXG10 SBTS provides integrated power and environment monitoring system and the monitor of the base station system involves no additional transmission resource.
• The Shelter may be applied in transmission of Microwave, SDH, PDH, and other modes of transmission.
• Two conditioners mounting on the wall work in timed shifts. This secures an operation temperature of 25 C 5C.
ZTE University www.univ.zte.com.cwww.univ.zte.com.cnnThe information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.
SHELTER BTS FLOOR LAYOUTSHELTER BTS FLOOR LAYOUT