Zenoro Premium Marine Generator Model: ZAMNLS5725HESE · 2018. 2. 2. · GENERATOR RATINGS PRIME...

Post on 01-Feb-2021

6 views 0 download

Transcript of Zenoro Premium Marine Generator Model: ZAMNLS5725HESE · 2018. 2. 2. · GENERATOR RATINGS PRIME...

  • GENERATOR RATINGS PRIME (KVA AT POWER FACTOR 0,8) Voltage Phase Amps ekW/KVA400/230 3 1032 572/715380/220 3 1086 572/715415/240 3 995 572/715

    MAN ENGINE SPECIFICATION

    V12, 4 CYCLE-DIESELEngine type D2862LE321Prime Power 600 kWmEmission IMO / Tier 2 compliantFiring order 1-12-2-11-3-10-6-7-5-8-4-9Displacement 24.24 L (1479 cu. in.)Rated engine speed 1500Bore 128 mm (5.04 in.)Stroke 157 mm (6.18 in.)Aspiration Singlestageturbocharged&after

    cooledNumberofValves 4valvespercylinderInjectionsystem CommonRailGovernor Electronicdieselcontrol(EDC)Coolingsystem PlateheatexchangerAirfilter 2xDuraliteairfilterRefillcapacity-Coolingsystem 100L(26.5USGAL)-Lubeoilsystem 70-90L(18.5-23.8USGAL)Fuelfilter Change-overtypeFuelpre-filterwithwater Change-overtype,loosesupplyLubeoilfilter Change-overtype,remoteseparator Oildrain&pump Servicesideelectrical24VpumpOilchangeinterval Upto600hourswhenfuel&oil

    requirements are metRotation(fromflywheelend) CounterclockwiseEnginecrankcaseventilationClosedtoeliminateengineroomsystem contaminationEngineblock High–strengthcastingwith

    integratedoil&waterductsandreplaceablecylinderliners

    Turbocharger&exhaust WatercooledmanifoldEnginelubrication Closedsystemwithforcedfeeding

    bygearpump,oilcoolingandfiltering

    AverageTBO 18.000operatinghours

    ENGINE ELECTRICALBatteryvoltage 24voltisolatedgroundStarter 7 kWBatterycharging 120AmpsBatteryrecommendation 175Ah,540amps(DIN43539),

    900 amps (DIN EN 50342)

    COOLING SYSTEMSeawaterpump GeardrivenimpellertypeMax.seawaterpumpsuctionlift -0,3to0,3barSeawaterpumpflow 420Lpm(111USGAL)Seawatertempmaximumenginein 32°CAmbienttemperaturemax.-IntakefromEngineroom 45°C-Intakewithinletduct 60°C

    FUELFuel recommended EN 590RecommendedfuellineinsidediameterLength20mmTotalfuelflow 700L/hr(185USGAL/hr)Max.suctionheadoffeedpump 0,35barMax.fuellevelabovefeedpump 0,2bar

    OPERATION REQUIREMENTS

    AIR REQUIREMENTSEnginecombustionair 45m3/minCoolingairflowrequired 84m3/minforgeneratorsetat50°CExhaustflow 95,2m3/minExhausttemperaturemax 348°CMax.Exhaustbackpressurewith 8,0kPAMin.Exhaustbackpressure 2,0kPA

    Zenoro Premium Marine GeneratorD2862LE321 Marine Generator Set 572 ekW / 50 HZ 1500 rpm

    POWER 572 ekW 400 V 50 HZ

    EMISSION IMO 2

    COLOURS RAL 9010 or custom

    ENCLOSURE aluminium modular design

    DIMENSIONS3590 x 1350 x 1460 mm

    WEIGHT

    dry weight 4780 kg

    SOUND REDUCTION equal or > than 20 dba at 1 meter

    free field conditions

    VIBRATIONSlow

    Model: ZAMNLS5725HESE

    Created by

  • FUEL CONSUMPTION*Dieselfuelconsumptionat%engineload100% 137l/hr (36.2USGAL/hr)75% 105,5l/hr (27.9USGAL/hr)50% 72l/hr (19USGAL/hr)

    Specificfuelconsumption196g/kWhat100%

    *Allabovevaluesatratedspeedandpower.Tolerance+5%accordingISO3046Specificfuelgravity0,853@60F(15.5C)

    ZENORO STANDARD FEATURES- Engine and alternator marine white painted- Steelframetosupportengine&alternator- Approvedvibrationisolators- Drippanunderneathoil&fuelfilters- 1xDryexhaust+exhaustcompensatorwithexhaust insulation

    - Junctionbox&controllerboxinonepiece,centralserviceconnector

    - Emergencybutton- ABS,BVclassification,otherclassificationsocietiesbyoption

    STANDARD ENGINE SAFETY SYSTEM- Enginefueloilpressurelowwarning&shutdown- Enginefueloilleakagefromdoublewalledpipeswarning- Enginelubeoilpressurelowwarning- Enginelubeoilpressurelowshutdown- Engine cooling water pressure low warning- Engine cooling water temperature high warning- Enginecoolantlevellowwarning- Overspeedshutdown- Belt guard

    STANDARD POSITION OF INTERCONNECTIONS- Fuelconnections,fuelinlet/outlet- Seawaterinletpipehoseconnection+rubberseals- Seawateroutletviapipehoseconnection+rubberseals- Oil drain- OpeningforAC-loadleads- Openingforbatterycables

    STANDARD HIGH QUALITY HEAVY DUTY SOUND ENCLOSURE- Highqualitymodularsoundenclosurewithaluminium extrusionprofiles

    - RAL9010standardcolor,2layersPowdercoating,70%gloss,minimum total layer thickness 120 micron measured according ISO 2808

    - Easilybuiltup&dismantle- Heavydutyservicepanels,easyremovable- Non-combustibleinsulationmaterialaccordingIMO (oil&vapourproof)

    - Separategenerator&enginecompartment

    ENGINE CONTROLLER PLATFORM FEATURES - CertifiedMarineEngineControllerwithredundant microprocessorbasedcontrolforcompleteengine protectionandcontrol

    - EnginesettingsavailableforDrooploadsharingeitherisochronous load sharing

    DISPLAY / USER INTERFACE- Graphic128×64pixelsdisplay- English language - Buttonswithmechanicalfeedback

    COMMUNICATION INTERFACES- Enginespeedup/downvoltageorcurrentcontrolled- Generatorreadytostart(pot.freecontact)- Enginerunning(pot.freecontact)- Commonwarning(pot.freecontact)- Commonshutdown(pot.freecontact)

    ENGINE CONTROL & PARAMETERSEnginefaultcodedescriptionsandcodesBlackoutstart,3startattemptsRemotestart&stop

    EngineparametersarevisualizedondisplayandorModbusRS232as:- Engine running hours - Engine status - Oilpressure - Coolanttemperature- Rpm - Engineloadin%- Batteryvoltage - Fuelconsumption

    HISTORY LOGS- Eventbasedhistory- Reason,DateandTime+allimportantvaluesarestored- Batterybacked-upRTC

    IMPORTANTEnginecontrolleronly,nogeneratorprotection, novoltage&power&currentmeasurements.Noparallelingfunctions.Yardresponsibility

    ZAMNL

    S572

    5HES

    E

    Created by

  • ALTERNATOR SPECIFICATIONManufacturer LeroySomerType LSAM49.1 L9Electrical output 572 ekW/715 KVAPowerfactor 0,8Voltageregulator AVR450+/-0,5%Typeofregulation AREPTempRise 115°CInsulationClass HBearing SinglerollerbearingCoupling FlexiblediscIP 23Spaceheater* 250W230/240VAC*Tobeconnected&switchedbyyard

    ALTERNATOR FEATURES- Compact&lowweight- Standard12wirere-connectablewinding,3-phasebrushless,

    2/3 pitch windings- Highefficiency- Shortcircuitcurrentupto300%ofratedcurrentfor10se-

    conds- Permanentlygreasedbearingsupto20.000h

    GENERAL- Plasticwrappacking- Manualssuppliedincdromformatwithinstruction,OperatingandMaintenanceManual(inPDFformatonly)

    - Factory Quality Report

    OPTIONAL - Wetexhaustmixeroutsideenclosureforoptimuminstallation- Wetexhausttemperaturehighwarning&shutdown- EnginecoolantlevellowwarningbyMurphygauge- Engineoiltemperaturesensorwarning&display- Seawaterflowsensor- ModbusconverterforRS485protocol- OptionalInternet/Ethernetconnectionforremotemonitoring- ElectriccablepenetrationswithRoxtec- Outsidemuffler&waterseparator- OtherClassificationsocietiesasDNV-GL,Lloyds,RINA- Unitcertificatesforcertainnotations- Manualsinhardcopyformat- Leroy Somer equipped with 3 phase sensing- Stainlesssteelunderplateforsingleelasticmounting- Doubleelasticsmounting:withheavyunderframeminimum40%ofweightabove,first&secondlayerofRubberDesignisolators

    OPTIONAL MARINE CERTIFIED CONTROLLER PACKAGEMarinecertifiedgeneratorcontrollerpackage:- Synchronizing,loadsharingandbreakercontrol- MeasurementanddisplayofVolts,amps,PF,KW,KVA,kVAr,kWh,kvaHr

    - Nosynchronizingtoshore- No power management- Circuitbreaker(motorized)- Other details on request

    OPTIONAL EXHAUST AFTER TREATMENT SYSTEMIMOTier3compliantemissionswithZeroNOxSystemZeroSootSystem,electric,fuelburnereitherpassiveavailable

    REFERENCE CONDITIONSRatedspeedandpoweraccordingISO3046(forclassification):- 100kPabarometricpressure- 318K(45°C)inletairtemperature- 60%inletairhumidity- 305K(32°C)seewatertemperature

    Subjecttomanufacturingandmeasurementvariationsand tochangewithoutnotice.Actualperformanceissubjectto applicationandoperationconditionsoutsideofZenorocontrol.

    RATINGSOperationprofile:upto5500hoursperyearandamaximumaverageload<75%

    MarineGenerator:TheMarinegeneratorengineratingisthepoweravailableundernormalvaryingelectricalloadfactors foranunlimitednumberofhoursperyearincommercial applications.Thisratingincorporatesa10%overloadcapability.

    Created by

    ZAMNL

    S572

    5HES

    E

  • DIMENSIONS

    146

    0

    3590 1350

    Cut-out forRoxtec frame (3x)

    500

    200

    500

    Service space

    Serv

    ice

    sp

    ac

    e

    Serv

    ice

    sp

    ac

    e

    Seawater return 76

    Seawater supply 76

    Fuel supply/return G1"Fuel supply/return G1"

    180 (6x)

    664 1008

    ZENORO | De Hammen 1 | 5371 MK Ravenstein | The Netherlands | +31 (0)486 201 600 | info@zenoro.com | www.zenoro.com

    Premium Generators for Superyachts

    NOTE:Generatorsetstobeinstalledabovewaterline.Ifnotconsultfactory. Thisdrawingisprovidedforreferenceonlyandisnotintendedforinstallationpurpose.Contactuseitheryourlocaldistributorfordetailedinformation.

    ZAMNL

    S572

    5HES

    E