VARIODYN D1 Update Michael Köhler. Annual Distributor Conference September 10-13, 2012 2 Michael...

Post on 14-Jan-2016

257 views 10 download

Tags:

Transcript of VARIODYN D1 Update Michael Köhler. Annual Distributor Conference September 10-13, 2012 2 Michael...

VARIODYN D1 Update

Michael Köhler

Annual Distributor Conference • September 10-13, 2012 • 2

Michael Köhler

Business Development VAPA International for D1Support for you and the Region

Sales- and Design Training Webinars Customer visits (e.g. Airports, Railway and Metros)

Voice of the customerNetworking with 3rd party supplier Networking between regions for global projects

Annual Distributor Conference • September 10-13, 2012 • 3

Why voice alarm?

Annual Distributor Conference • September 10-13, 2012 • 4

How we do the cabling for speakers

today ?

Annual Distributor Conference • September 10-13, 2012 • 5

Star cabling

DOM

EOLblackredgreyD

OM

Annual Distributor Conference • September 10-13, 2012 • 6

Star cabling

DOM

EOLblackredgreyD

OM

Annual Distributor Conference • September 10-13, 2012 • 7

Star cabling

DOM

EOLblackredgreyD

OM

Annual Distributor Conference • September 10-13, 2012 • 12

Is this the best way to do it ?

? ??

?

?

Annual Distributor Conference • September 10-13, 2012 • 13

? ??

?

? ??

Annual Distributor Conference • September 10-13, 2012 • 14

We proudly present:

Annual Distributor Conference • September 10-13, 2012 • 15

A new way of Speaker cabling!

Annual Distributor Conference • September 10-13, 2012 • 16

LOOP Film

Annual Distributor Conference • September 10-13, 2012 • 17

LOOP Isolator Module (LIM) 583342

Standard OBO housing for the Loop Isolator Module (LIM)

85 x 85 x 40.5 mm outside diameter

IP 66 possible

No special DOM’s needed!

Annual Distributor Conference • September 10-13, 2012 • 18

loop

spur

mix

•Basis of the LOOP technology is the DOM

•Different topologies : spur, loop and mix of both

•DOM 4-8 and DOM 4-24

LOOP Isolator Module (LIM) 583342

Annual Distributor Conference • September 10-13, 2012 • 19

LOOP Isolator Module (LIM) 583342

• Up to 4 LOOPs @ one DOM• Up to 64 LOOP Isolator Modules per LOOP• Up to 500 W power per LOOP• Up to 1000 m length per LOOP Ring (diameter is important)

• EN 54-16 and EN 54-17 (Isolator) certified

Available !

Annual Distributor Conference • September 10-13, 2012 • 20

VARIODYN D1LOOP Technology

DOM

LIM LIM LIM

LIMLIM

LOOP Variant 1

Annual Distributor Conference • September 10-13, 2012 • 21

VARIODYN D1LOOP Technology

DOM

LIM LIM

LIMLIM

LOOP Variant 2

Annual Distributor Conference • September 10-13, 2012 • 22

VARIODYN D1LOOP Technology

DOM

LIM LIM

LIMLIM

LOOP Variant 1 & 2

Annual Distributor Conference • September 10-13, 2012 • 23

How to full fill “A/B” requirements

Annual Distributor Conference • September 10-13, 2012 • 24

LOOP Isolator Module (LIM) 583342

Annual Distributor Conference • September 10-13, 2012 • 25

LOOP Isolator Module (LIM) 583342

Annual Distributor Conference • September 10-13, 2012 • 26

LOOP Isolator Module (LIM) 583342

Annual Distributor Conference • September 10-13, 2012 • 27

How many LOOPs @ a DOM?

Annual Distributor Conference • September 10-13, 2012 • 28

Increase security and availability - better than A/B Cabling

No Speaker loss in case of cable break

Loss of max. one segment in case of short circuit

Technically substitution for fire resistant cables

LOOP - Advantages

Annual Distributor Conference • September 10-13, 2012 • 29

How it will help to do more???

Annual Distributor Conference • September 10-13, 2012 • 30

A Great Differentiator

Technically – the best solution in the market!

Tender – not easy for others; no local competition

Topic to discuss with Consultants and End users

We can set a trend (LOOP instead of spur’s)

How it will help to do more???

Annual Distributor Conference • September 10-13, 2012 • 31

Siemens and Dräger only OEM (Astrea)Acousto and Astrea are “old fashioned” PA

system Bosch and TOA haven't currently any solution! g+m - no EN54-16 and -17 certification so far!

Competition only in Netherland

Annual Distributor Conference • September 10-13, 2012 • 32

Olympia

Netherlands

Netherlands ???

Annual Distributor Conference • September 10-13, 2012 • 33

Annual Distributor Conference • September 10-13, 2012 • 34

Annual Distributor Conference • September 10-13, 2012 • 35

Annual Distributor Conference • September 10-13, 2012 • 36

Competition is only active in

Netherlands

Switzerland

Our chance to push this !

Annual Distributor Conference • September 10-13, 2012 • 37

New UPS

Annual Distributor Conference • September 10-13, 2012 • 38

New VARIODYN D1 - UPS

Annual Distributor Conference • September 10-13, 2012 • 39

Just two U heighVARIODYN D1 DesignUp to 210A(!) power on 24 Volt3 single protected 24V outputs for 3 DOM‘s6 single protected 24V outputs for 6 amp‘sEN54-4 certified

New VARIODYN D1 - UPS

Already Availible !!!

Annual Distributor Conference • September 10-13, 2012 • 42

The New VARIODYN D1 VCS

Annual Distributor Conference • September 10-13, 2012 • 43

Compatible to all D1 components

VARIODYN D1 VCS

Annual Distributor Conference • September 10-13, 2012 • 44

Control unit oft the small PA/VA system

VCS = VARIODYN D1 Compact System

• DOM, UIM and VCM functionality

• Additional 12 free programmable keys and Plug

to connect Handheld Microphone

• 19“ form factors; 3U height

VARIODYN D1 VCS

Annual Distributor Conference • September 10-13, 2012 • 45

• Programmable with Designer

• LOOP Technology compatible

• In- and outputs (Audio and digital IO contact’s)

• 24 Speaker Lines

• Ethernet integrated

Availible QI 2013 ; EN54-16 certified QII 2013

VARIODYN D1 VCS

Annual Distributor Conference • September 10-13, 2012 • 46

Our amplifier line up

Annual Distributor Conference • September 10-13, 2012 • 47

Digital Power Amplifier:2x250W (Class D) 2XD2502x400W (Class D) 2XD400

2x250W (Class D) 2XA250 (from Honeywell AV)Only for PA amplications

Current Power Amplifier Line Up

Annual Distributor Conference • September 10-13, 2012 • 48

? ??

?

? ??

Annual Distributor Conference • September 10-13, 2012 • 49

The New VARIODYN D1 4XD125B

Annual Distributor Conference • September 10-13, 2012 • 50

Availible Q1 /2013; EN54-16 certified QII / 2013

VARIODYN D1 4XD125

Annual Distributor Conference • September 10-13, 2012 • 51

MMIAmp.

Module 4Amp.

Module 3Amp.

Module 2Amp.

Module 1

Power supply Module

Backplane with PSU

aspirators

VARIODYN D1 4XD125

Annual Distributor Conference • September 10-13, 2012 • 52

Amplifier inclusive UPS• 4 Channel AMP each 125W (4x250W in the roadmap)

• For VARIODYN D1 (DOM and VCS)

• Class D, efficiency > 80%

• Housing 1U (4x125W)

• 3 to 1 Backup possible (!)

• Battery charger included (up to 24V / 65 Ah) (!)

No additional UPS needed!

VARIODYN D1 4XD125

Annual Distributor Conference • September 10-13, 2012 • 53

One D1 Family

Annual Distributor Conference • September 10-13, 2012 • 54

VCS

4XD125B DOM 4-8

2XD250

2XD250

VARIODYN D1 – one family

Annual Distributor Conference • September 10-13, 2012 • 55

Where can help me the 4XD125B?

Annual Distributor Conference • September 10-13, 2012 • 56

Solution for small applications

Annual Distributor Conference • September 10-13, 2012 • 57

Very small solutions

• Backup (1:3)

• 375 Watt / 18 Line

• EN54-16

• EN60849

• A/B Cabling and

LOOP possible!

Annual Distributor Conference • September 10-13, 2012 • 58

Application exampleHigh Riser

Annual Distributor Conference • September 10-13, 2012 • 59

High Risser Solution

• One DOM 4-8, 4XD125 and two Batteries

• each for three (or four) floors

• Short Speaker Line Cables

• Redundant Ethernet over Fiber

Annual Distributor Conference • September 10-13, 2012 • 60

High Risser Solution

Level 12

Level 11

Level 10

Level 9

Level 8

Level 7

Level 6

Level 5

Level 4

Level 3

Level 2

Level 1

• Backup (1:3)

• A/B Cabling

• EN54-16

• EN60849

• LOOP possible!

Annual Distributor Conference • September 10-13, 2012 • 61

Decentralized Systems

Annual Distributor Conference • September 10-13, 2012 • 62

DAL 1

Modular concept

19“ Rack

DAL 1

19“ Rack

DAL 1

19“ Rack

Ethernet

Annual Distributor Conference • September 10-13, 2012 • 63

PAMMI (Easy Installation)

Annual Distributor Conference • September 10-13, 2012 • 64

PAMMI (Easy Installation)

The configuration for up to 10 DOMs will be much easier

Including tools for the GUI

Change of graphic possible for you and enduser

Annual Distributor Conference • September 10-13, 2012 • 65

PAMMI (Easy Installation)

Annual Distributor Conference • September 10-13, 2012 • 66

PAMMI (Easy Installation)

Annual Distributor Conference • September 10-13, 2012 • 67

Future Product Roadmap

Annual Distributor Conference • September 10-13, 2012 • 68

Availible QVI 2013; EN54-16 certified QI / 2014

VARIODYN D1 4XD250

Annual Distributor Conference • September 10-13, 2012 • 69

Amplifier inclusive UPS• 4 Channel AMP each 250W

• For VARIODYN D1 (DOM and VCS)

• Class D, efficiency > 80%

• Housing 2U

• 3 to 1 Backup possible (!)

• Battery charger included (!)

No additional UPS needed!

VARIODYN D1 4XD250

Annual Distributor Conference • September 10-13, 2012 • 70

Drivers

Proprietary

SERVERSERVER

Redundant server

SQL-DB

Scripts

Automation Level Management Server Clients

Web client

Multi-monitor desktop client

Web client with printer

Web client as touch panel

New Management System

Annual Distributor Conference • September 10-13, 2012 • 71

Advantages of New GUI

Highly scalable From small business up to high-end solutions to

optimally fit the regional market requirements

Enhanced flexibility Platform independent web access through browser,

desktop and mobile clients

Higher usability New editor module with extended functionalities

Availible Q1 / 2014

Annual Distributor Conference • September 10-13, 2012 • 72

Why should I try to sell D1 ???

Annual Distributor Conference • September 10-13, 2012 • 73

? ??

?

? ??

Annual Distributor Conference • September 10-13, 2012 • 74

? ??

?

? ??

! !

!

!

! !!

Annual Distributor Conference • September 10-13, 2012 • 75

Nice!But what are the five most important

advantages?

Annual Distributor Conference • September 10-13, 2012 • 76

Advantage ONE

Highly Scalable and Decentralized System No restriction > any input to any output No single point of failure More than 100 Channels / time Integrated Record and Playback Unit Best protected invest

Annual Distributor Conference • September 10-13, 2012 • 77

Advantage Two

Low Number of components Low live time costs Very easy Design Very easy installation and commissioning

Annual Distributor Conference • September 10-13, 2012 • 78

Advantage Three

PAMMI GUI including DVA! Monitoring

Annual Distributor Conference • September 10-13, 2012 • 79

Advantage Four

Sound quality and Product quality Excellent Sound Low System Delay (max 30ms)

Annual Distributor Conference • September 10-13, 2012 • 80

Advantage Five

European Product with Local Support!

Annual Distributor Conference • September 10-13, 2012 • 81

You forgot one !!!

Annual Distributor Conference • September 10-13, 2012 • 82

Thank You!Thank You!