Sub-ps bunch length measurements at the JLab FEL with coherent transition radiation (CTR) and...

Post on 01-Apr-2015

219 views 2 download

Tags:

Transcript of Sub-ps bunch length measurements at the JLab FEL with coherent transition radiation (CTR) and...

Sub-ps bunch length measurementsat the JLab FEL

with coherent transition radiation (CTR) and “Martin-Puplett” interferometer

Pavel Evtushenko, JLab

The key principles of the diagnostic

Operation of the Matrin-Puplett interferometer

An examples of data

Low frequency cut-off

Data Evaluation in frequency domain

Pulsed beam vs. CW beam measurements

ps and sub-ps bunch length measurements using CTR

1. Transition radiation is produced when the electron bunch passes a boundary of two media.

2. Respond time is zero. Shape of the radiation pulse is a

“copy” of the electron bunch shape.

3. When the wave length of the radiation becomes more than the bunch length the radiation becomes COHERENT. ( L )

4. Power is proportional to:incoherent radiation N coherent radiation N2

5. Measurements of the radiation spectrum give information about the bunch length.

Coherent radiation power spectrum

˜ E b(ω ) ∝ ˜ E S k(ω )e iωτ k

k

Pb(ω ) = ˜ E b(ω ) ˜ E b*(ω ) = ˜ E S k(ω )e iωτ k ˜ E S

*j(ω )e−iωτ j

j

∑k

Pb(ω ) = Ps(ω ) N e + e iω (τ k −τ j )

j ≠k

∑k

∑ ⎛

⎝ ⎜ ⎜

⎠ ⎟ ⎟

PS (ω ) = ˜ E S (ω ) ˜ E S*(ω )

e iωτ k

k

∑ ≡ N e fb(t)e iωtdt∫ = ˜ f b(ω )

Pb(ω ) = PS (ω ) N e − N e( N e +1) ˜ f b(ω )2

[ ]

˜ f b(ω )2

Eb(r r ,t) = ES k(

r r ,t −τk )

k

∑ - Coulomb field of electron bunch

- Fourier transform of the Coulomb field

- Power spectrum of the bunch

- Power spectrum of a single electron

- Bunch Form Factor (BFF)

The Martin-Puplett interferometer operation

The Martin-Puplett interferometer

The Martin-Puplett interferometer

)tt(g)t(gE2RT)t(E 0||out

dt)t(g)t(g)t(gRTE)(U 2

||2

o

)t(gE)t(E 0in

the autocorrelation function ismeasured with the help of the MPI

The Wiener-Khintchine theorem says: “the Fourier transform of the autocorrelation functionis the power spectrum”.

longitudinal field profileat the MPI entrance

longitudinal field profileat the MPI exit

detectors measureintensity IE2

The MPI scan

16 17 18 19 20 210.05

0.10

0.15

0.20

0.25

0.30

0.35

0.40

0.45

0.50

Am

plitu

de o

f th

e G

olay

cel

l sig

nal,

V

mirror position, mm

Golay #1 Golay #2

Interferogram - the normalized difference

16 17 18 19 20 21

-0.2

-0.1

0.0

0.1

0.2

0.3

0.4

Inte

nsity

, a. u

.

mirror position, mm

The use of two detectors: raw data vs. interferogram

Bunch length reconstruction

2

t 2

t

t

e2c

Qtn

2teCP~

2t4

0 eCe1)(f fit

0.0 0.2 0.4 0.6 0.8 1.00.0

0.2

0.4

0.6

0.8

1.0

diffraction on the Golay cell input window

4

0e1

2

0e1

Gol

ay c

ell a

pert

ure

tran

smis

sion

Frequency, THz

the Gaussian shapeof the bunch is assumed

its power spectrum isalso Gaussian

low frequency cut-offdiffraction on the Golaycell input window

two filter functionswere considered:

20e11F filter

40e12F filter

The fit function is used

Jlab FEL CTR interferogram

step size – 5 um, 128 steps

Jlab FEL CTR spectrum and the fit function

JLab FEL (layout and longitudinal matching)Requirements on phase space:• Long bunch in linac• high peak current (short bunch) at FEL

– bunch length compression at wiggler• “small” energy spread at dump

– energy compress while energy recovering– “short” RF wavelength/long bunch get slope and curvature right

E

f

E

f

E

f

E

f

modified Martin-Puplettinterferometer (step scan)is used with CTR;only tune (pulsed) beam

Michelson interferometer(rapid scan)is used with CSR;CW beam

Interferometers

We use two different interferometers;essentially both are a modificationof the Michelson interferometer.

The two interferometers differ inimplementation; Beam splitter Polarizer Detector Focusing element Mirror position measurements

Modified Marin-Puplett interferometer:(step scan device) beam splitter & polarizer (wire grids) detector (Golay cell) focusing (Plano-convex lens) mirror position is set by step motorUsed with CTR

Michelson interferometer:(rapid scan device 2 sec/scan) beam splitter (silicon) detector (pyroelectric) focusing (parabolic mirrors) mirror position is measured by another built-in interferometerUsed with CSR

Pulsed beam measurements; RMS 148 fs

The mod. Martin-Puplett interferometer (the Happek device) measurements

CW beam measurements 0.31 mA; RMS 147 fs

CW beam measurements 0.62 mA; RMS 151 fs

CW beam measurements 1.25 mA; 163 fs

CW beam measurements 2.51 mA; 145 fs

Pulsed beam measurements vs. CW beam

The bunch length does not change with beam current.