Limit Switches Product Panorama

Refer to Catalog 9006CT0101

Design Standard Duty Industrial Severe Duty Mill and Foundry

Catalog number 9007C XCKJ XCKS 9007T/FT L100/L300

Enclosure Metal, diecast, zinc alloy Metal Plastic, double insulated Metal Metal

Features Plug-in bodyFixed or plug-in body, -40 °C(-40 °F) or +120 °C (+248 °F)versions

—Extra heavy dutycontact ratings

Extra heavy dutycontact ratings

Modularity Head, body, and lever Lever

Conforming to standards / Product certifications

UL 508, C22-2-14-95,NEMA 250, IEC 60947,EN 60947-1, EN 60947-5-1

CENELEC:EN 50041

CENELEC:EN 50041

NEMA A600 UL508UL Listed, CSA Certified

NEMA A600 UL508UL Listed, CSA Certified

Body dimensions (w x h x d),mm (in.)

Standard:39 x 102 x 45 (1.54 x 4.02 x 1.77)Compact:39 x 80 x 45 (1.54 x 3.15 x 1.77)

40 x 77 x 44 (1.57 x 3.03 x 1.73)42.5 x 84 x 36 (1.67 x 3.31 x1.42)

40 x 72.5 x 36(1.57 x 2.85 x 1.42)

58.7 x 114.3 x 64.5(2.31 x 4.5 x 2.54)

58.7 x 126 x 53.3(2.31 x 4.95 x 2.10)

Head

Linear movement, plunger

Rotary movement, leverMulti-directional movement(wobble stick, cat whisker) c 

Linear movement, plunger

Rotary movement, leverRotary movement,multi-directional c 

Linear movement, plunger

Rotary movement, leverRotary movement,multi-directional c 

Rotary movement, lever Rotary movement, lever

Contact blocks — —

2 snap action contacts — N.C. + N.O.; N.C. + N.C. N.C. + N.O.; N.C. + N.C. — —

2 snap action contacts — N.C. + N.O.; N.C. + N.C. N.C. + N.O.; N.C. + N.C. — —

3 snap action contacts —N.C. + N.C. + N.O.;N.C. + N.O. + N.O.

N.C. + N.C. + N.O.;N.C. + N.O. + N.O.

— —

3 snap action contacts —N.C. + N.C. + N.O.;N.C. + N.O. + N.O.

N.C. + N.C. + N.O.;N.C. + N.O. + N.O.

— —

4 snap action contacts — — — — —

4 snap action contacts — — — — —

2 slow break contactsbreak before make

— N.C. + N.O. — — —

2 slow break contactsbreak before make

— N.C. + N.O. — — —

2 slow break contactsmake before break

— N.O. + N.C. — — —

2 slow break contactsmake before break

— N.O. + N.C. — — —

2 slow break contactssimultaneous

— N.C. + N.C. — — —

2 slow break contactssimultaneous

— N.O. + N.O. N.O. + N.O. — —

3 slow break contactsbreak before make

—N.C. + N.C. + N.O. ;N.C. + N.O. + N.O.

N.C. + N.C. + N.O.;N.C. + N.O. + N.O.

— —

3 slow break contactsbreak before make

—N.C. + N.C. + N.O. ;N.C. + N.O. + N.O.

N.C. + N.C. + N.O.;N.C. + N.O. + N.O.

— —

1 slow break contactForm Y1561 a 

1 N.C — — — —

2 snap action contacts 1 N.O. + 1 N.C. 2 C/O 2 C/O1 N.C. + 1 N.O.b

convertible sequence1 N.C. + 1 N.O.b

fixed sequence

4 snap action contacts2 N.O. + 2 N.C. ;2 N.O. + 2 N.C. , neutral position;2 N.O. + 2 N.C. , two stage

— — — —

Insulation voltage (Ui) andthermal current (Ithe)

Ui = 600 V, except:9007C62, 9007C66, 9007C68(Ui = 250 V)and 9007C84, 9007C86 (Ui = 125 V)

Ithe = 10 A, except:9007C84, 9007C86 (Ithe = 2.5 A)

Screw terminal 2 contacts: 500 V/10 A3 contacts: 400 V/6 A

Connector Integral M12, 5-pin: 60 V / 4 AIntegral 7/8" 16UN: 250 V / 6 A

Screw terminal 2 contacts: 500 V/10 A3 contacts: 400 V/6 A

600 V20 A (AC/DC)

600 V20 A (AC), 5 A (DC)

Enclosure ratingIP = IEC enclosure ratingIK = EN shock test standard

IP 67 conforming to IEC 60529,NEMA Types 2, 4, 6, 6P, 12, 13

NEMA Types 1, 2, 4, 12IP 66, IK 07

IP 65, IK 03NEMA Types 1, 2, 4, 12, 13IP65, 66, 67

NEMA Types 1, 4, 13IP65, 66

Electrical connection

Cable entry 1/2"-14 NPT,M20 x 1.5 ISO cable entry

Connector 5-pin mini connector.

Screw terminal 1 entry for ISO M20 or PG 13conduit thread or 1/2" NPT

Connector Integral M12 or 7/8" 16UN

Screw terminal 1 entry for ISO M20 orPG 13 conduit thread

Cable entry1/2" NPT (metric available)

Cable entry1/2" NPT (metric available)

Connector available

a Single pole only. Refer to page 21-26 for details.b For other contact options, see catalog 9006CT0101.c Flexible operators do not guarantee direct (positive) opening operation.

8/2/2019 Limit Switches and Drawings

http://slidepdf.com/reader/full/limit-switches-and-drawings 2/11

www.schneider-electric.us

2  1  

L I MI T S WI T CHE S 

21-4  © 2009 Schneider ElectricAll Rights Reserved

Application Data All Limit Switch Types

Refer to Catalog 9006CT0101

a Indicates NEMA or IEC Type Rating available for each product.b For indoor use only—not UV protected.c Enclosure ratings are NEMA 1, 2, 3, 4, 6, 6P, 12, and 13 except for option 21 (low force)

which is NEMA 1 only. The 9007 MS/ML05 (omni-directional operation) enclosure ratingsare NEMA 1, 2, 12, and 13.

Some switches are available with higher or lower temperature limits, byselecting special versions or special options. Refer to the respectiveproduct sections for further information. (Ex.: 9007MS/ML, seepage 21-9.)

f Type C52 compact unit ratings at 125 Vdc—same ratings as C54, CF53 and CR53 atother voltages.

Table 21.1: Enclosure Ratings

TypeNEMA Style IEC Style

1 2 3 4 4X 6 6P 7 9 12 13 IP65 IP66 IP67

9007C a a a a a a a a a a

9007CR a a a a a a a a a

9007FT a a a a a a a a

L100/L300 a a a a a

9007MS/ML c a a a a a a a a a

9007T a a a a a a a a

XCKJ a a a a a a

XCKL a a a a a a

XCKN & XCNR a a a

XCKP & XCKT b a a a a

XCKS, XCMN a

XCMD, XCKD a a a a a a

Table 21.2: Sealing

Type Material

9007C, CR

Standard shaft seals on lever types Viton ® fluorocarbon

Plunger and wobble stick boots Neoprene d

All other seals Nitrile (Buna N) d

R.B.Denison ® L PVC

9007T and FT

Shaft seal Nitrile (Buna N)

Cover gasket Nitrile (Buna N)

Base plate gasket Cellulose fiber laminate

XCKJ, XCKL, XCKS Nitrile (Buna N)

XCMD, XCKD, XCKP, XCKT, XCKN, XCNR Nitrile (Buna N) and silicon

d Fluorocarbon seals are available in place of nitrile and neoprene on 9007C.

Table 21.3: Ambient Temperature Ranges

The low temperatures listed below are based on the absence offreezing moisture or water. Care should be taken to avoid sub-freezingtemperatures where dripping or splashing water is present and to avoidbringing a cold switch into a warm humid atmosphere and then backinto sub-freezing temperatures. The water or moisture can freezearound the switch lever arm or plunger and cause jamming

Type Low TemperatureHigh Temperatureat Full Rated Load

9007 C

Lever Type -20 °F (-28.9 °C) +185 °F (+85 °C)

Plunger & Wobble Stick Type 0 °F (-17.8 °C) +185 °F (+85 °C)

9007 FTe, T -10 °F (-23 °C) +185 °F (+85 °C)

HL100/HL300 0 °F (-17.8 °C) +350 °F (+177 °C)

L100/L300 0 °F (-17.8 °C) +200 °F (+93 °C)

9007 MS/ML -4 °F (-20 °C) +221 °F (+105 °C)

XCKJ, XCKL, XCKP, XCKT -13 °F (-25 °C) +158 °F (+70 °C)

XCMN, XCKN, XCNR -13 °F (-25 °C) +158 °F (+70 °C)

XCKS -13 °F (-25 °C) +158 °F (+70 °C)

XCMD -13 °F (-25 °C) +158 °F (+70 °C)

e The Type FT will withstand hot falling sand up to +300°F (+149 °C); however, ambient temperature for the FT switch is the same as the Type T above (+185 °F,+85 °C). Do not use in higher temperature ambients.

Table 21.4: Electrical Contact Ratings

AC—NEMA A600 DC

Volts

Max. Current—35% Power Factor

Volts

Maximum Current

Make Break ContinuousCarryingAmperes

Make or Break ContinuousCarryingAmperesA VA A VA A VA

120 60 7200 6 720 10 125 1.1/0.55 f 138/69 f 5/2.5 f

240 30 7200 3 720 10 — — — —

480 15 7200 1.5 720 10 250 0.27 67.5 2.5

600 12 7200 1.2 720 10 600 0.10 60 2.5

Table 21.5: Contact Function Diagrams

Make-before-break (overlapping) SPDTThe normally open contact closes before thenormally closed contact opens.

Break-before-make (offset) SPDTThe normally closed contact opens before thenormally open contact closes.

Simultaneous make and break—SPDTThe normally closed contact opens at the sametime as the normally open contact closes.

Table 21.6: Wiring Diagrams

Form A Form B Form C Form AA Form BB Form CC Form X Form Y Form Zb Form Z Form XX Form YY Form ZZ

SPST-NO SPST-NC SPDT DPST-NO DPST-NC DPDTSPST-NO-DB

SPST-NC-DB

SPDT-DBIsolated Contacts

SPDT-DBDPST-NO-DB

DPST-NC-DB

DPDT-DB

B

C0 D

21 - 2213 - 14

21 - 2213 - 14

A

P

tripping

resetting

A=Maximum travel of the operator in mm or degrees.B=Tripping travel of the contact.C=Reset travel.D=B-C=Differential travel.P=Point from which positive opening is assured

21-22

13-14

21-22

13-14

21-22

13-14

8/2/2019 Limit Switches and Drawings

http://slidepdf.com/reader/full/limit-switches-and-drawings 3/11

PICKET FENCE THICKENER

INSTALLATION, OPERATION and MAINTENANCE MANUAL

Page 18 / 18

MASS ARITMA SİSTEMLER İ İNŞ AAT SANAY İ VE TİCARET ANONİM ŞİRKETİ Gebze Organize Sanayi Bölgesi İhsan Dede Caddesi 700.Sokak PK.1052 Gebze 41480 Kocaeli-Türkiye

Phone: +90 262 751 22 10 pbx Fax: +90 262 751 07 30e-mail : info@massaritma.com

5. TECHNICAL DRAWING

8/2/2019 Limit Switches and Drawings

http://slidepdf.com/reader/full/limit-switches-and-drawings 4/11

8/2/2019 Limit Switches and Drawings

http://slidepdf.com/reader/full/limit-switches-and-drawings 5/11

8/2/2019 Limit Switches and Drawings

http://slidepdf.com/reader/full/limit-switches-and-drawings 6/11

8/2/2019 Limit Switches and Drawings

http://slidepdf.com/reader/full/limit-switches-and-drawings 7/11

8/2/2019 Limit Switches and Drawings

http://slidepdf.com/reader/full/limit-switches-and-drawings 8/11

8/2/2019 Limit Switches and Drawings

http://slidepdf.com/reader/full/limit-switches-and-drawings 9/11

8/2/2019 Limit Switches and Drawings

http://slidepdf.com/reader/full/limit-switches-and-drawings 10/11

8/2/2019 Limit Switches and Drawings

http://slidepdf.com/reader/full/limit-switches-and-drawings 11/11