General Purpose Transformers SOLA/HEVI-DUTY
Selection Tables: Single PhaseGroup IA - 240 x 480 Volt Primary, 120/240 Secondary, 60 Hz (Encapsulated) Listed . Certified
KVA
.050
.075
.100
.150
.250
.500
.750
1
1.5
2
3
5
7.5
10
CatalogNumber
HS1B50
HS1B75
HS1B100
HS1B150
HS1B250
HS1F500B
HS1F750B
HS1F1BS
HS1F1.5AS
HS1F2AS
HS5F3AS
HS5F5AS
HS5F7.5AS
HS5F10AS
Height(inch)
7
7
7
7.5
7.5
10
10
10
13
13
13
17
17
28
Width(inch)
4
4
4
5
5
6
6
6
10
10
10
14
1 4
14
Depth(inch)
3
3
3
4
4
5
5
5
7
7
7
9
9
9
Ship WeightApprox. (Ibs)
3
3
4
5
8
22
23
28
39
47
55
104
135
156
DesignStyle
2
2
2
2
2
3
3
3
4
4
4
4
4
4
ElecConn
1
1
1
1
1
1
1
2
2
2
3
3
4
4
PrimaryAmps
.208/.104
.31 21. 156
.417/.208
.625/.313
1.04/.512
2.08/1.04
3.13/1.56
4.17/2.08
6.25/3.13
8.33/4.17
12.5/6.25
20.8/10.4
31.3/15.6
41 .7/20.8
SecondaryAmps
.416/.208
.625/.312
.833/.417
1.25/.625
2.08/1.04
4.16/2.08
6.25/3.13
8.33/4.17
12.5/6.25
16.7/8.33
25.0/12.5
41 .6/20.8
62.5/31.3
83.3741. 7
Note: See Section 7 for Higher KVA encapsulated units.
Group IB - 240 x 480 Volt Primary, 120/240 Secondary, 60 Hz
KVA
15
25
37.5
50
75
100
167
250*
CatalogNumber
S5H15S
S5H25S
S5H37S
S5H50S
S5H75S
S5H100S
S5H167S
S5H250S
NEMA3RWeatherShield
WS-01
WS-15
WS-17
WS-17
WS-09
WS-09
WS-16
N/A
Height(inch)
23
28
31
31
44
44
46
65
Width(inch)
14
16
18
18
23
23
26
36
Depth(inch)
16
16
18
18
21
21
24
35
Ship WeightApprox. (Ibs)
160
230
310
380
555
650
905
1580
DesignStyle
11111111
ElecConn
5
5
5
5
5
5
5
5
PrimaryAmps
62.5/31.3
104/52.1
156/78
208/104
313/156
41 7/208
695/348
1042/521
•SecondaryAmps
125/62.5
208/104
313/156
416/208
625/313
833/417
1 392/695
2083/1042
* Not UL or CSA Approved
Group II - 120/208/240/277 Volt Primary, 120/240 Secondary, 60 Hz
KVA
1
1.5
2
3
5
7.5
10
15
25
CatalogNumber
HS12F1BS
HS12F1.5AS
HS12F2AS
HS12F3AS
HS12F5AS
HS12F7.5AS
HS12F10AS
S12H15S
S12H25S
NEMA3RWeatherShield
N/A
N/A
N/A
N/A
N/A
N/A
N/A
WS-01
WS-15
Height(inch)
10
13
13
13
17
1 7
17
23
28
Width(inch)
6
10
10
10
14
14
14
14
16
Depth(inch)
5
7
7
7
9
9
9
16
16
Ship WeightApprox. (Ibs)
29
40
60
66
104
135
156
200
250
DesignStyle
3
4
4
4
4
4
4
1
1
ElecConn
9
10
10
10
10
10
10
1111
PrimaryAmps*
3.6
5.4
7.2
10.8
18.0
27.1
36.1
54.2
90.3
SecondaryAmps
8.33/4.17
12.5/6.25
16.7/8.33
25.0/12.5
41 .6/20.8
62.5/31.3
83.3/41.7
125/62.5
208/104
* Amperage calculated at 277 Volts on primary.Fax-on-Demand #: (877) 888-9329, Document #: 8332
72 Contact Technical Services at (800) 377-4384 with any questions.
General Purpose Transformers
Listed Certified
Single Phase: .05-.250 KVA Features• UL-3R enclosure for indoor or
outdoor service.• Fast, easy installation.
Mounting holes built into theenclosure.
• Low temperature rise, ULclass 105°C insulationsystem, 55°C temperaturerise under full load. Can bebanked for three phase service.
• Nonmetallic nameplates listall rating data. Wiring diagramstrategically located oninside of wiring (Mlcompartment cover.
• Conduit knockouts for side entry into roomy wiringcompartment.
• Copper lead wire terminations.• Quiet operation.
Single Phase: .500-10 KVAThree Phase: 3-9 KVA Features
• UL-3R enclosures for indoor or outdoor service.• Fast, easy installation.• Electrostatically shielded for quality power on sizes
1 KVA and larger.• Efficient operation. UL class 180°C insulation system,
115°C temperature rise under full load. Can be bankedfor three phase service.
• Conduit knockouts for side entry into roomy wiringcompartment.
Design Styles
w
H
Style 1
• Copper lead wire terminations.• Units 1 -10 KVA are encapsulated with electrical grade
silica sand and epoxy for rugged applications.• Nonmetallic nameplates list all rating data. Wiring
diagram strategically located on inside of wiringcompartment cover.
Single Phase: 15-250 KVAThree Phase: 15-500 KVA Features
• UL class 220°C insulation system, 150°C temperaturerise under full load.
• Electrostatically shielded for quality power.• Front connected terminal board and spacious wiring
compartment.• UL-3R outdoor enclosures when used with optional
weather shields (order separately).• Panel enclosure design reduces labor time. Remove
only two bolts for entry. Wiring diagram on inside frontcover.
• Core and coil completely isolated from enclosure bymeans of vibration dampening pads to provide quietoperation.
Accessories and Design Styles• Wall mounting brackets - for ventilated design units,
single and three phase, 15 to 75 KVA. The catalognumber for all wall brackets is WB-1C.
• Totally enclosed non-ventilated designs are availablefor sizes 15 KVA and larger.
• Core and coil designs are available for sizes 15 KVAand larger.
• Surge Suppression Devices (page 5) provide additionalprotection and longevity to any electronic equipment.
• Weather Shields.
W
H
CD
Style 2
70Fax-on-Demand #: (877) 888-9329, Document #: 8331
Contact Technical Services at (800) 377-4384 with any questions.
SOLA/HEVI-DUTY General Purpose Transformers
Construction Features
• Free Shielding• Easy Installation• 10 Years+2 Warranty
UL-3R EnclosuresFast Delivery
High impact powder paint finish
Remove two bolts forinterior access, frontor rear.
UL-3R Enclosure(with optional weathersrueld)
Large, easy to readwiring diagraminside front cover.
Shielded forquality power
Easily accessedtap connections.
Coils
Vibration and sounddampening pad.
Fiberglass terminalboard relieves cablestress.
Enclosure bottomdesigned for ventilationand rodent protection.
Flexible ground strap(included but not shown).
Fax-on-Demand #: (877) 888-9329, Document #: 8331Contact Technical Services at (800) 377-4384 with any questions. 71
General Purpose Transformers
Electrical Connections (Single Phase)
240 X 480 Volt Primary120/240 Volt Secondary Taps: None
H1 H3 1
PrimaryVoltage
SecondaryVoltage
H1 to H3H2 to H4
X1 to X3X2 to X4
Connect Lines to
Connect Lines to
240 X 480 Volt Primary,120/240 Volt Secondary ATaps: 2, 21/2% FCAN; 4, 21/2% FCBN H1
H1 H2H3H4H5 H6H7H8H9 H10
LAJv-A-XJ UUJv-Aj
-L o^rVv ,̂ rv-vVv^~ ^xr
SHIELD I r-̂ S I
X1 X3 X2 X4
PrimaryVoltage
504
492
480
468
456
444
432
252
240
228
216
SecondaryVoltage
240
120/240
120
Interconnect
H5 to H6
H4 to H6
H4 to H7
H3 to H7
H3 to H8
H2 to H8
H2 to H9
H1 to H6H5to H10
H1 to H7H4to H10
H1 to H8H3to H10
H1 to H9H2to H10
Interconnect
X2 to X3
X2 to X3
X1 to X3X2 to X4
Connect Lines to
H1 & H10
H1 & H10
H1 & H10
H1 & H10
H1 & H10
H1 & H10
H1 & H10
H1 & H10
H1 & H10
H1 & H10
H1 & H10
Connect Lines to
X1 & X4
X 1 . X 2 & X 4
X1 &X4
240 X 480 Volt Primary120/240 Volt Secondary Taps: None
PrimaryVoltage
SecondaryVottage
120/240
Interconnect
H1 to H3H2 to H4
Interconnect
X1 to X3X2 to X4
Connect Lines to
Connect Lines to
X1 & X4
240 X 480 Volt Primary,1 20/240 Volt Secondary i*Taps: 2, 21/2% FCAN; 4, 21/2% FCBN **
H1 H2(1 0
7 5 3 1 2 4 6 8
^_A_/^^AAAA_AA>J V>^AAAAAAAAAA_.
\(' SHIELD
X1 X3 X2 X4
PrimaryVoltage
504
492
480
468
456
444
432
252
240
228
216
SecondaryVoltage
240
120/240
120
Interconnect
1 to 2
2 to 3
3 to 4
4 to 5
5 to 6
6 to 7
7 to 8
H1 to 2H2to1
H1 to 4H2to3
H1 to 6H2to5
H1 to 8H2to 7
Interconnect
X2 to X3
X2 to X3
X1 to X3X2 to X4
Connect Lines to
H1 & H2
H1 & H2
H1 & H2
H1 &H2
H1 & H2
H1 & H2
H1 & H2
H1 & H2
H1 & H2
H1 & H2
H1 & H2
Connect Lines to
X1 & X4
X 1 . X 2 & X 4
X1 &X4
240 X 480 Volt Primary 120/240 VoltSecondary Taps: 2, 21/2% FCAN & FCBN
3H1 H2 H3 H4 H5 H6 H7 H8
L>^A_A_X_A_X>J UV>LA_/LA^AJprv> r̂S^w~\ rv'YVv'V'w^ '1I r̂ S I SHIELD
X1 X3 X2 X4
PrimaryVoltage
504
492
480
468
456
252
240
228
SecondaryVoltage
240
120/240
120
Interconnect
H4 to H5
H3 to H5
H3 to H6
H2 to H6
H2 to H7
H1 to H5H4 to H8
H1 to H6H3 to H8
H1 to H7H2 to H8
Interconnect
X2 to X3
X2 to X3
X1 to X3X2 to X4
Connect Lines to
H1 & H8
H1 & H8
H1 & H8
H1 & H8
H1 & H8
H1 & H8
H1 & H8
H1 & H8
Connect Lines to
X1 & X4
X1 , X2 & X4
X1 & X4
600 VoltTaps: N
Ht
tX
Primary, 120/240 Volt Secoone
1 H• 4
>~A_A^A_^A-A^A_A^VAA-A--VA^
1 X3 X2 X
PrimaryVottage
600
SecondaryVoltage
240
120/240
120
Interconnect
Interconnect
X2 to X3
X2 to X3
X1 to X3X2 to X4
ndary
62i
i4
Connect Lines to
H1 & H2
Connect Lines to
X1 & X4
X 1 , X2& X4
X1 &X4
Note: 1 through 2 KVA units haveelectrostatic shielding.
78Fax-on-Demand #: (877) 888-
Contact Technical Services at (800)9329, Document #: 8334377-4384 with any questions.
General Purpose Transformers SOLA/HEVI-DUTY
Specification Guide for Low Voltage, General Purpose,Dry Type Transformers (600 Volt Class) -15 KVA and larger
GeneralSingle and three phase distribution transformers(600 Volt and below)
• Provide and install, as referenced on the electricalplans, enclosed dry type transformers as manufacturedby Sola/Hevi-Duty or approved equal.
Standards• Transformers must be listed by Underwriters
Laboratory, certified with Canadian StandardsAssociation and designed, constructed and rated inaccordance with NEMA ST 20, ANSI C89.2 andapplicable IEEE & OSHA specifications.
ConstructionCores• All transformer cores shall be constructed of low loss,
high quality, electrical grade laminate steel. By design,the flux density is to be kept well below the saturationlevel to reduce audible sound level and minimize corelosses. The core volume shall allow operation at 10%above rated primary voltage at no load withoutexceeding the temperature rise of the unit.
Coils• Coil conductors shall be either aluminum or copper and
must be continuous. The entire core and coil assemblyshall be impregnated with a thermal setting varnish andcured to reduce hot spots in the coils and seal outmoisture. Coils with exposed magnet wire will not beacceptable. Transformers shall have common coreconstruction.
• All transformers shall incorporate a faraday(electrostatic) shield between primary and secondarywindings for the attenuation of voltage spikes, linenoise and voltage transients.
• Transformers shall be provided with six 2.5% fullcapacity taps - two above and four below primary ratedvoltage.
• General purpose transformers are classified asisolation transformers.
Enclosures• Transformer enclosures shall be constructed of heavy
gauge sheet steel and coated with a grey powder paintfinish (ANSI 61). Ventilated transformer enclosuresshall be UL/NEMA Type 2 rated and UL/NEMA Type3R rated for outdoor use with the addition of aweathershield. This information must be listed on thetransformer nameplate.
• Maximum transformer enclosure temperature willnot exceed 65°C rise above a 40°C ambient underfull load.
• Transformers must have vibration isolators locatedbetween the core and coil assembly and thetransformer enclosure to reduce audible sound levelscaused from magnetostriction of the transformer core.No externally located vibration dampening pads shallbe used as they tend to increase audible noise.Ventilated transformers are to be floor mounted to aconcrete pad.
• The transformer enclosure must be grounded by theinstaller in accordance with the latest edition of theNational Electric Code and any local codes orordinances.
Performance• Audible sound levels will not exceed limits established
in NEMA/ANSI Standard C89.2:
10 to 50 KVA 45 db51 to 150 KVA 50 db151 to 300 KVA 55 db301 to 500 KVA 60 db
• Transformers, 15 KVA to 500 KVA, shall incorporate aUL recognized 220°C insulation system and exhibit amaximum 150°C temperature rise above a maximumambient of 40°C under full load.
84Fax-on-Demand #: (877) 888-9329, Document #: 8336
Contact Technical Services at (800) 377-4384 with any questions.