Post on 15-Jul-2020
Domonial Wireless Alarm System
TCPA Keyfobs
July 2013
Honeywell Proprietary
Honeywell.com
2
TCPA Keyfobs
• Ergonomic and compact design
• Multiple accessories fitting all usages
• Water resistance
• LED to acknowledge successful command
• Backward compatibility – TCPA1B: 1-button -> emulation of TCM800HF (on Domonial)
– TCPA2B: 2-button -> emulation of TCBPA8M-1 (on Domonial)
– See compatibility table for other panels
• Added value functions – Panic Alarm, Drive of actuators, Arming/Disarming, Door bell (with
upcoming new panel firmware)
– Supervision (with upcoming new panel firmware)
Honeywell Proprietary
Honeywell.com
3
Wireless Keyfobs Range
Honeywell Proprietary
Honeywell.com
4
Compatibility with other Panels
Honeywell Proprietary
Honeywell.com
5
TCPA1B 1-Button Panic Alarm Keyfob
APPLICATIONS
• Panic/Hold-up alarm
• Life comfort
• User supervision
BENEFITS
• Usable all time
• Simple to operate
• Well fitting design
• Long battery life
KEY FEATURES
• Panic Alarm (default)
• Multi-wear accessories
• Water resistant IP67
• Supervised (upcoming)
• Status LED
• 4 years battery life
• Alpha, V2, Alpha Russia
radio protocols
• Backward compatible
• Other optional modes: • Home automation
• Doorbell (upcoming)
• User supervision (upcoming)
Honeywell Proprietary
Honeywell.com
6
TCPA2B 2-Button Panic Alarm Keyfob
APPLICATIONS
• Panic/Hold-up alarm
• Life comfort
• User supervision
BENEFITS
• Usable all time
• Simple to operate
• Well fitting design
• Long battery life
KEY FEATURES
• Panic Alarm (default)
• Multi-wear accessories
• Water resistant IP67
• Supervised (upcoming)
• Status LED
• 4 years battery life
• Alpha, V2, Alpha Russia
radio protocols
• Backward compatible
• Other optional modes: • Home automation
• Setting/Unsetting
• User supervision (upcoming)
Stickers
included
Honeywell Proprietary
Honeywell.com
7
Multi-wear Accessories Included
Pendant
Belt clip / Wall/Desk mount
Keychain
Wristband
Honeywell Proprietary
Honeywell.com
8
Wall/Desk Mount of Bracket Accessory
Possible hole
positions for
wall or desk
mount
• Make a hole in the predefined hole positions.
• Use screws with a head thickness of less than 2mm
Honeywell Proprietary
Honeywell.com
9
Enrolment on Domonial
REGISTRATION PROCEDURE
• First, set the panel to registration mode
• To start registration, press the keyfob button for 5
seconds. The LED will start blinking.
• The keyfob will try to register with the following
sequence of radio protocols: Alpha, V2, Alpha Russia
• On DomoPC 6.0 the keyfob are enroled with the
« TCB800M » type. The new « TCPA1B » or
« TCPA2B » type are supported starting from
DomoPC 6.2
• After the first registration, to enroll again the keyfob
with a different panel remove and put the battery
back before starting the registration procedure
Honeywell Proprietary
Honeywell.com
10
TCPA1B Configuration
CONFIGURATION VIA DOMOPC
• Select the wanted button behavior on the Alert column of the
Keyfobs/Standard settings window for the registered keyfob
• Current panels only offer Alert1/2/3 options. Other optional
TCPA1B modes will be supported by upcoming panel SW
Honeywell Proprietary
Honeywell.com
11
TCPA2B Configuration – DomoPC 6.0
CONFIGURATION VIA DOMOPC 6.0
• Select the wanted buttons behavior using the following
Keyfobs settings: • Long push (2s) of both buttons Standard tab / Alert column
• Right button Advanced tab / «Ctrl+Part Arm» column
• Left button Advanced tab / «Ctrl+Arm» column
• Short push (300ms) of both buttons Advanced tab / «Ctrl+Disarm» column
• Current panels only offer some options. Other optional
TCPA2B modes will be supported by upcoming panel SW
Honeywell Proprietary
Honeywell.com
12
TCPA2B Configuration – DomoPC 6.2
CONFIGURATION VIA DOMOPC 6.2
• Select the wanted buttons behavior using the
following settings in the Keyfobs Advanced tab: • Short push (300ms) of both buttons Short double push
• Long push (2s) of both buttons Long double push
• Right button
• Left button
• Current panels only offer some options. Other
optional TCPA2B modes will be supported by
upcoming panel SW
Honeywell Proprietary
Honeywell.com
13
Battery Replacement
BATTERY REPLACEMENT
1. Remove 4 screws (①) and lift off cover.
2. Using a small flat-blade screwdriver remove old battery (②).
3. Insert new battery by placing new battery under the gold tab
and then pressing down (③). Ensure the positive (+) side of
battery is face up after installation
4. Align cover and attach with 4 screws
NOTE: When replacing the battery, wait a minimum of 10 seconds prior to
installing the new battery
Honeywell Proprietary
Honeywell.com
14
Battery Lifetime
BATTERY LIFETIME
• Battery lifetime depends on number of activations per
month and supervision period
• Protocol alpha example: more than 4 years of lifetime
with 200 activations per month without supervision
Honeywell Proprietary
Honeywell.com
15
THANK YOU
Honeywell Proprietary
Honeywell.com
16
Enrolment on Vista (1/2)
SELECTION OF THE PROTOCOL
• To work with Vista + 5882EUHS, TCPA1B/TCPA2B must
be set into V2 protocol
• This must be done BEFORE enrolment on panel − TCPA1B: press the button for 5sec
− TCPA2B: press simultaneously both buttons for 5sec
• Then, the keyfob LED will blink during 10-15sec
• Without any « answer » coming back in ALPHA or
RUSSIA protocol, the keyfob will be automatically set in
V2
• IMPORTANT: This must be done before setting the panel
into enrolment mode.
Honeywell Proprietary
Honeywell.com
17
Enrolment on Vista (2/2)
ENROLMENT As any other keyfob working with Vista panels, enrolment
will be done by pressing the button(s) on panel request.
1. Enter in programming mode (install code +8+0+0)
2. Enter in zone programming (*56)
3. Select zone where keyfob will be enrolled
4. Choose appropriate zone type (mostly 06-07: panic
silent or audible, or any other type desired)
5. Select RF button
6. For enrolment, on panel request, press the keyfob
button (TCPA1B) or the 2 buttons simultaneously
(TCPA2B)
7. Press the button(s) again, and if requested confirm a
3rd time
8. Program then alpha description, pass to another zone
or exit zone programming with 00.
10 Input S/N L
AXXX-XXXX 1
Xmit to Confirm
Press * to Skip