Model 265B - Autotechs -catalog of remote transmitters, keyfobs
Domonial Wireless Alarm System TCPA Keyfobs...Domonial Wireless Alarm System TCPA Keyfobs July 2013...
Transcript of Domonial Wireless Alarm System TCPA Keyfobs...Domonial Wireless Alarm System TCPA Keyfobs July 2013...
Domonial Wireless Alarm System
TCPA Keyfobs
July 2013
Honeywell Proprietary
Honeywell.com
2
TCPA Keyfobs
• Ergonomic and compact design
• Multiple accessories fitting all usages
• Water resistance
• LED to acknowledge successful command
• Backward compatibility – TCPA1B: 1-button -> emulation of TCM800HF (on Domonial)
– TCPA2B: 2-button -> emulation of TCBPA8M-1 (on Domonial)
– See compatibility table for other panels
• Added value functions – Panic Alarm, Drive of actuators, Arming/Disarming, Door bell (with
upcoming new panel firmware)
– Supervision (with upcoming new panel firmware)
Honeywell Proprietary
Honeywell.com
3
Wireless Keyfobs Range
Honeywell Proprietary
Honeywell.com
4
Compatibility with other Panels
Honeywell Proprietary
Honeywell.com
5
TCPA1B 1-Button Panic Alarm Keyfob
APPLICATIONS
• Panic/Hold-up alarm
• Life comfort
• User supervision
BENEFITS
• Usable all time
• Simple to operate
• Well fitting design
• Long battery life
KEY FEATURES
• Panic Alarm (default)
• Multi-wear accessories
• Water resistant IP67
• Supervised (upcoming)
• Status LED
• 4 years battery life
• Alpha, V2, Alpha Russia
radio protocols
• Backward compatible
• Other optional modes: • Home automation
• Doorbell (upcoming)
• User supervision (upcoming)
Honeywell Proprietary
Honeywell.com
6
TCPA2B 2-Button Panic Alarm Keyfob
APPLICATIONS
• Panic/Hold-up alarm
• Life comfort
• User supervision
BENEFITS
• Usable all time
• Simple to operate
• Well fitting design
• Long battery life
KEY FEATURES
• Panic Alarm (default)
• Multi-wear accessories
• Water resistant IP67
• Supervised (upcoming)
• Status LED
• 4 years battery life
• Alpha, V2, Alpha Russia
radio protocols
• Backward compatible
• Other optional modes: • Home automation
• Setting/Unsetting
• User supervision (upcoming)
Stickers
included
Honeywell Proprietary
Honeywell.com
7
Multi-wear Accessories Included
Pendant
Belt clip / Wall/Desk mount
Keychain
Wristband
Honeywell Proprietary
Honeywell.com
8
Wall/Desk Mount of Bracket Accessory
Possible hole
positions for
wall or desk
mount
• Make a hole in the predefined hole positions.
• Use screws with a head thickness of less than 2mm
Honeywell Proprietary
Honeywell.com
9
Enrolment on Domonial
REGISTRATION PROCEDURE
• First, set the panel to registration mode
• To start registration, press the keyfob button for 5
seconds. The LED will start blinking.
• The keyfob will try to register with the following
sequence of radio protocols: Alpha, V2, Alpha Russia
• On DomoPC 6.0 the keyfob are enroled with the
« TCB800M » type. The new « TCPA1B » or
« TCPA2B » type are supported starting from
DomoPC 6.2
• After the first registration, to enroll again the keyfob
with a different panel remove and put the battery
back before starting the registration procedure
Honeywell Proprietary
Honeywell.com
10
TCPA1B Configuration
CONFIGURATION VIA DOMOPC
• Select the wanted button behavior on the Alert column of the
Keyfobs/Standard settings window for the registered keyfob
• Current panels only offer Alert1/2/3 options. Other optional
TCPA1B modes will be supported by upcoming panel SW
Honeywell Proprietary
Honeywell.com
11
TCPA2B Configuration – DomoPC 6.0
CONFIGURATION VIA DOMOPC 6.0
• Select the wanted buttons behavior using the following
Keyfobs settings: • Long push (2s) of both buttons Standard tab / Alert column
• Right button Advanced tab / «Ctrl+Part Arm» column
• Left button Advanced tab / «Ctrl+Arm» column
• Short push (300ms) of both buttons Advanced tab / «Ctrl+Disarm» column
• Current panels only offer some options. Other optional
TCPA2B modes will be supported by upcoming panel SW
Honeywell Proprietary
Honeywell.com
12
TCPA2B Configuration – DomoPC 6.2
CONFIGURATION VIA DOMOPC 6.2
• Select the wanted buttons behavior using the
following settings in the Keyfobs Advanced tab: • Short push (300ms) of both buttons Short double push
• Long push (2s) of both buttons Long double push
• Right button
• Left button
• Current panels only offer some options. Other
optional TCPA2B modes will be supported by
upcoming panel SW
Honeywell Proprietary
Honeywell.com
13
Battery Replacement
BATTERY REPLACEMENT
1. Remove 4 screws (①) and lift off cover.
2. Using a small flat-blade screwdriver remove old battery (②).
3. Insert new battery by placing new battery under the gold tab
and then pressing down (③). Ensure the positive (+) side of
battery is face up after installation
4. Align cover and attach with 4 screws
NOTE: When replacing the battery, wait a minimum of 10 seconds prior to
installing the new battery
Honeywell Proprietary
Honeywell.com
14
Battery Lifetime
BATTERY LIFETIME
• Battery lifetime depends on number of activations per
month and supervision period
• Protocol alpha example: more than 4 years of lifetime
with 200 activations per month without supervision
Honeywell Proprietary
Honeywell.com
15
THANK YOU
Honeywell Proprietary
Honeywell.com
16
Enrolment on Vista (1/2)
SELECTION OF THE PROTOCOL
• To work with Vista + 5882EUHS, TCPA1B/TCPA2B must
be set into V2 protocol
• This must be done BEFORE enrolment on panel − TCPA1B: press the button for 5sec
− TCPA2B: press simultaneously both buttons for 5sec
• Then, the keyfob LED will blink during 10-15sec
• Without any « answer » coming back in ALPHA or
RUSSIA protocol, the keyfob will be automatically set in
V2
• IMPORTANT: This must be done before setting the panel
into enrolment mode.
Honeywell Proprietary
Honeywell.com
17
Enrolment on Vista (2/2)
ENROLMENT As any other keyfob working with Vista panels, enrolment
will be done by pressing the button(s) on panel request.
1. Enter in programming mode (install code +8+0+0)
2. Enter in zone programming (*56)
3. Select zone where keyfob will be enrolled
4. Choose appropriate zone type (mostly 06-07: panic
silent or audible, or any other type desired)
5. Select RF button
6. For enrolment, on panel request, press the keyfob
button (TCPA1B) or the 2 buttons simultaneously
(TCPA2B)
7. Press the button(s) again, and if requested confirm a
3rd time
8. Program then alpha description, pass to another zone
or exit zone programming with 00.
10 Input S/N L
AXXX-XXXX 1
Xmit to Confirm
Press * to Skip