Digital Infrared Thermal Imaging

Post on 31-May-2015

179 views 17 download

Tags:

description

Thermography

Transcript of Digital Infrared Thermal Imaging

DITI-Meditherm

By Duran-durantian@epc.com.hk

Marketing Countries Over the World

Access

Milestone

Establishment

Applications of Meditherm

• Early Detection of Breast Cancer for Younger Women between 30 & 50

Athletic Injuries, especially for Equine, such as, Stress Fractures, Compartment Syndromes, and Reflex Sympathetic Dystrophy

Pre & post treatment Follow-up observation

Age Average Tumor

Doubling Time

Under 50 80 Days

Between 50 – 70 157 Days

Over 70 188 Days

Source: Cancer 71:3547-3551, 1993

Active Cancer Cells Double in Number Every 90 Days

90 days 2 cells

1 year 16 cells

2 years 256 cells

3 years 4,896 cells

4 years 65,536 cells

5 years 1,048,576 cells (still undetectable)

6 years 16,777,216 cells

7 years 268,435,456 cells

8 years 4,294,967,296 cells (doubled 32 times) *

*Normally detectable by Mammogram at this stage

40 Doublings (Aprox 10 Years) considered lethal.

Sequential recording at 5 minute

intervals with needles in place

Baseline

before

needle

placement

Stabilized

result after

needle

removal

Patients with diagnosed CFS and Fibromyalgia

Pack

ag

e

Inclu

des

Scanner, case, stand & laptop

computer with configured software

Comprehensive operator training

course, certification to technician level

Online thermogram interpretation

service available

Full 2 years warrantee & 1st year

service contract with technical support

Cam

era

Weight: 2.1 kg

Optimized between 17℃ to 40℃with

better sensitivity and accuracy

Operating Temperatures: 18℃ to 38℃

Size: 26.5cm W x 31.3cm H x 13.5cm D

Imag

e d

isp

lay

1x16-step HD grayscale

3x16-step HD Isotherm

Display Color: 256 & 16 step medical

and custom colormaps

Temperature step sizes: 0.1℃ - 20℃

Image stored in TIF format

Image size 95kb/135kb/200kb

Imag

e

Acq

uis

itio

n Thermal sensitivity: < 0.01℃Field of view: 50°/32°/25°/17°/11°

Temperature ranges:

10℃ to 40℃ (Standard Calibration)

Automatic ambient correction

Spatial resolution: 0.4 mm (camera at

15 cm), 1mm (camera at 40 cm)

傷患紀錄 [過去12個月] (截至 2014年6月24日星期二) 顯示範圍 :

Meditherm

Digital Infrared Thermal Imaging REPORT Horse:

Owner / Trainer:

Veterinarian:

Scan Date:

Scan Ref:

Thermographer:

Clinical notes from client: Horse lame after morning gallop, no obvious cause or signs.

All normal protocols were observed. Reported by:

There is significant inflammation seen throughout the right front fetlock with a temperature

differential of 4.55℃. Localisation shows a focal transverse area of inflammation in the

upper posterior part of the fetlock.

There are patterns of hyperthermia seen throughout the tendons between the right knee and

fetlock with increased hyperthermia below the posterior knee.

There are no other significant asymmetries seen throughout the horse.

Pack

ag

e

Inclu

des

Scanner, case, stand & laptop

computer with configured software

Comprehensive operator training

course, certification to technician level

Online thermogram interpretation

service available

Full 2 years warrantee & 1st year

service contract with technical support

Cam

era

Weight: 2 kg

Optimized between 17℃ to 40℃with

better sensitivity and accuracy

Operating Temperatures: 10℃ to 37℃

Size: 14cm W x 43cm H x 11cm D

Imag

e d

isp

lay

1x16-step HD grayscale

3x16-step HD Isotherm

Display Color: 256 & 16 step medical

and custom colormaps

Temperature step sizes: 0.1℃ - 20℃

Image stored in TIF format

Image size 95kb/135kb/200kb

Imag

e

Acq

uis

itio

n Thermal sensitivity: < 0.01℃Field of view: 50°/32°/25°/17°/11°

Temperature ranges:

10℃ to 40℃ (Standard Calibration)

Automatic ambient correction

Spatial resolution: 0.4 mm (camera at

15 cm), 1mm (camera at 40 cm)

Non-invasive

No radiation

Painless

Early Stage

FDA proofed

Sensitive to 0.01 degree.

Each pixel could be compared to others

Specially designed & calibrated for human medical & clinical temperature range

Industry leader with largest network of doctors and technicians worldwide

Unique Optimized Accurate Safe

No consumables,

Simpler,

Full body exam takes less than 15 minutes per patient with simple operation in clinics

Save images to PC & Generate report online.

Access to EMI interpretation system for case study

Generate good bottom line profits with minimal investment and time

Efficient PortableMaintenance free

Profitable

Romania

Australia

Canada

United States

Oman

China

American College of Clinical Thermology

Electronic Medical Interpretation

Tianrui Physical Examination

University of Uppsala