Digital Breast Tomosynthesis: Future of visualization

Post on 22-Feb-2016

71 views 0 download

Tags:

description

Digital Breast Tomosynthesis: Future of visualization. MIIT – 2013 Toronto Ketan Thanki. FFDM Vs DBT. Single Frame images Conventional Data sets Established workflow. Multi-Frame image stacks Larger Data sets Intensive workflow: dynamic browsing through image stacks. - PowerPoint PPT Presentation

Transcript of Digital Breast Tomosynthesis: Future of visualization

MIIT 2013

Digital Breast Tomosynthesis: Future of visualizationMIIT – 2013 TorontoKetan Thanki

5/24/2013

2

FFDM Vs DBTFu

ll Fi

eld

Dig

ital

Mam

mog

raph

y • Single Frame images

• Conventional Data sets

• Established workflow

Dig

ital

Bre

ast

Tom

osys

nthe

sis • Multi-Frame

image stacks

• Larger Data sets

• Intensive workflow: dynamic browsing through image stacks

3

Visualization challenges of DBT study

Limitation of LCD response & cine through multiple images1

Detection probability while scrolling through slices2

Workflow & Time to interpret3

4

Limitation of LCD response & cine through multiple images1

LCD Response time deceiving

Large Variations in transition times

2-3 Frames to refresh

Result: Blurring20ms of

Frame time 50+ ms of transition time

5

Blurring on traditional FFDM display during cine

6

Detection probability while scrolling through slices2

[Lia06] Temporal Response Measurements of Medical Liquid Crystal Displays, Hongye Liang and Aldo Badano, SPIE medical Imaging 2006

Slow average transition times

Blurring when browsing through

image stack

Result: Masking of subtle image

features Eg. On a typical 5 MegaPixel medical display, the fastest transition is +/- 15ms while the slowest transition requires 150ms (more than 10 display frames) to complete (source: [Lia06])

7

Subtle details during cine

8

Workflow & Time to interpret3

• Flicker…Pan/Zoom

• Freeze & focus…Magnify

(Continuous zoom)

• Slow fading…Toggle comparison

9

Some Technologies

10

Rapidframe

Blurring during cine Smooth cine

11

Rapidframe Clinical pilot results:

Browsing speed: 25 slices/second

10% higher AUC compared to FFDM

display

Statistically significant

12

Ultra high luminance

x2

x1

13

Ultra-high Luminance:

PACS display= 500 cd/m2

Tomo display = 1000cd/m2

“Hot light”= 2000 cd/m2

Hot Light toolTemporary boostfor subtle details

14

JNDs: Visible shades of gray

Hot Light toolTemporary boostfor subtle details

15

Quantification of Detection Probabilityof Microcalcifications at Increased Display

Luminance Levels

16

Tomosynthesis Displays:

Three factors for efficient reading time and accuracy

Cine without blur technology

Ultra-high luminance with “Hot light” for subtle details

Display controller with enough memory to hold large stacks of images10-bit imaging:Synchronized to display refresh rate & frame rate

17

References

Medical Display optimized for Digital Breast Tomosynthesis▫ T Kimpe, MS, Kortrijk, _ BEL; A Xthona; C Marchessoux

Quantification of Detection Probability of Micro-calcifications at Increased Display Luminance Levels

▫ Tom R.L. Kimpe and Albert Xthona

Multimodality breast imaging using RapidFrame™▫ Albert Xthona