Post on 16-Aug-2020
HIGH DENSITY EQUIPMENT PANEL (HDEP) ORDERING GUIDE
24-Fiber MPO System10/40/100 GbE Migration Solution
Table of Contents
HDEP System Overview 3
HDEP 24-Fiber Interconnect System10 Gigabit Interconnect
Introduction ............................................................................................................................ 42-Fiber LC- A-B Patch Cord ........................................................................................................ 41x24 Fiber MPO to 12 x duplex LC Module, Straight A-A/B-B ........................................................ 4MPO Trunk, Polarity A .............................................................................................................. 41x24 Fiber MPO to 12 x duplex LC Module, Flipped A B/B-A ........................................................ 41 and 4 RU Chassis (not shown in system diagram) ....................................................................... 4Ordering Information ................................................................................................................ 5Specifications ......................................................................................................................... 5
HD 10 Gigabit Interconnect
8-Fiber HD Array ..................................................................................................................... 62x6 MPO Module .................................................................................................................. 6MPO Trunk, Polarity A .............................................................................................................. 640G MPO Patch Cord, Polarity A .............................................................................................. 61 and 4 RU Chassis (not shown in system diagram) ....................................................................... 6Ordering Information ................................................................................................................ 7Specifications ......................................................................................................................... 7
40 Gigabit Interconnect
1x3 MPO Array ..................................................................................................................... 8MPO Module ......................................................................................................................... 8MPO Trunk, Polarity A .............................................................................................................. 81 and 4 RU Chassis (not shown in system diagram) ....................................................................... 8Ordering Information ................................................................................................................ 9Specifications ......................................................................................................................... 9
100 Gigabit Interconnect
Introduction .......................................................................................................................... 10MPO Patch Cord, Polarity A .................................................................................................... 10MPO Module ....................................................................................................................... 10MPO Patch Cord, Polarity B .................................................................................................... 101 and 4 RU Chassis (not shown in system diagram) ..................................................................... 10Ordering Information .............................................................................................................. 11Specifications ....................................................................................................................... 11
HDEP Cross-Connect System10 Gigabit Cross-Connect
Introduction .......................................................................................................................... 122-Fiber LC A-B-Patch Cord ....................................................................................................... 121x24 Fiber MPO to 12 x duplex LC Module, Straight A-A/B-B ...................................................... 12MPO Trunk, Polarity A ............................................................................................................ 121x24 Fiber MPO to 12 x duplex LC Module, Flipped A-B/B-A ...................................................... 121 and 4 RU Chassis (not shown in system diagram) ..................................................................... 12Ordering Information .............................................................................................................. 13Specifications ....................................................................................................................... 13
HD 10/40 Gigabit Cross-Connect
Introduction .......................................................................................................................... 148-Fiber HD Array ................................................................................................................... 142x6 MPO Module ................................................................................................................. 14MPO Trunk, Polarity A ............................................................................................................ 1440G MPO Patch Cord, Polarity B ............................................................................................ 1440G MPO Patch Cord, Polarity A ............................................................................................ 141 and 4 RU Chassis (not shown in system diagram) ..................................................................... 14Ordering Information .............................................................................................................. 15Specifications ....................................................................................................................... 15
40 Gigabit Cross-Connect
Introduction .......................................................................................................................... 1640G MPO Patch Cord, Polarity A ............................................................................................ 162x6 MPO Module ................................................................................................................. 16MPO Trunk, Polarity A ......................................................................................................... 1640G MPO Patch Cord, Polarity B ............................................................................................ 161 and 4 RU Chassis (not shown in system diagram) ..................................................................... 16Ordering Information .............................................................................................................. 17Specifications ....................................................................................................................... 17
100 Gigabit Cross-Connect
Introduction .......................................................................................................................... 18MPO Patch Cord, Polarity A .................................................................................................... 18MPO Module ....................................................................................................................... 18MPO Trunk, Polarity A ............................................................................................................ 18MPO Patch Cord, Polarity B .................................................................................................... 181 and 4 RU Chassis (not shown in system diagram) ..................................................................... 18Ordering Information .............................................................................................................. 19Specifications ....................................................................................................................... 19
For more information, visit commscope.com
High Density Equipment Panel System Overview
3
24-Fiber Trunking SolutionsBandwidth and storage demand is expanding at a breathtaking rate. The environment is rapidly evolving. The impact on data center design and management is profound. Networks will migrate from 10 to 40 to 100 Gigabit/second Ethernet speeds dynamically, and data center managers and designers need to be able to manage this migration to maximize efficiency and responsiveness while minimizing cost.
This dynamic migration demands a simple yet robust migration pathway, and successful migration starts with a simple yet robust plan. This guide presents just such a concise and manageable plan to allow migration of infrastructure, whether it be core switching, aggregation, end of row, top of rack or hybrid network architectures.
Centered around 24-fiber trunks and optical connectivity, this roadmap provides the following advantages:
• A single trunking format that can be replicated and upgraded simply and flexibly
• Unified solutions for 10, 40 and 100 GbE applications
• Pre-engineered paths and polarity
• Higher fiber utilization versus 12-fiber systems
• Fewer trunks
• Fewer connections
• Fewer components
• Standardized practices for design, installation, documentation and troubleshooting
• Component and trunk re-use
• Minimized waste of space, time and money
The following pages provide this plan--designs and products for each step of your network’s evolution to 100 GbE, allowing your data center strategy to become a dynamic business advantage.
40Gor 100G*
100G† 100G†
*100G implemented as 4x25G †100G implemented as 10x10G
10G
40Gor 100G*
10G
For more information, visit commscope.com4
High Density Equipment Panel 10 Gigabit Interconnect
Introduction
The 10 Gigabit Interconnect solution, like all of the planned migration designs, begins with a 24-fiber optical trunk with a single, two-row MPO-type connector at each end. Trunks interface with the rear of a 1 or 4 rack unit (RU) high HDEP chassis, which contains up to six 24-fiber MPO to LC modules per RU. These 24-fiber modules break out the trunk fibers into 12 duplex LC connections at the front of each module, supporting 144-fibers per RU.
Modules reside in a multi-featured HDEP chassis which provides superior cable management for both the MPOs at the rear and LC cords at the front. HDEP chassis are stackable and available in 1 and 4 RU versions in both unmanaged and managed formats. They can be populated all at once, or added to or upgraded a module at a time in the future. The HDEP chassis also supports high density 10 Gigabit modules, as well as 40 and 100 GbE versions, allowing an upgrade path by changing the module at the front and employing existing and additional 24-fiber trunks at the rear.
Fiber Module 24-Fiber Trunk
1 RU Chassis
11
24-Fiber MPO Trunk A-Polarity (Type A)
MPO MPO
LC-Duplex A-B Patch Cord
LC-Duplex A-B Patch Cord
LC-Duplex LC-Duplex
2 4
3
24-Fiber MPO-LC Modules
24-Fiber MPO-LC Modules
4 RU Chassis
For more information, visit commscope.com5
High Density Equipment Panel 10 Gigabit Interconnect
Specifications
MPOptimate Performance: Factory assembled and tested, 0.35 dB maximum insertion loss per module
Traceable: Each module is uniquely identified and linked to factory measurement data
Standard Fiber Path: Compatible with TIA 568-C.0-2 draft standard for polarity method “A”
24-Fiber Trunk: Fiber path supports 24-fiber deployment
Pinned Module: MPO alignment pins are maintained inside the module, reducing risk of damage during installation and use
Module used in Pairs: Provides proper fiber map, polarity and location of MPO alignment pins
Flexible: Chassis enables superior cable management and can be stacked in standard 19-inch racks or cabinets
Ordering Information
Number Component Part Number
1 2-Fiber LC A-B Patch Cord FPCTB-MDLC-D-xM
2Unmanaged Module, LC-MPO Aqua, 24 fibers (1x24F MPO rear port), straight fiber path, Optimate performance
N5MP-24DLMR4AP (Right)
N5MP-24DLML4AP (Left)
3 24-Fiber Trunk, Polarity A OM4 MPT-2C2CM40xxxF-FF
4Unmanaged Module, LC-MPO Aqua, 24 fibers (1x24F MPO rear port), flipped fiber path, Optimate performance
N5MP-24DLMR4BP (Right)
N5MP-24DLML4AP (Left)
N/S Chassis 1 RU N5CHU-1RU
N/S Chassis 4 RU N5CHU-4RU
Note: x or xxx denotes length F = feet or M = meters and may be changed accordingly based on ordering preference
10 Gigabit LC-MPO Solution
For more information, visit commscope.com6
High Density Equipment Panel High Density 10 Gigabit Interconnect
Introduction
HDEP High Density 10 Gigabit Fiber modules also utilize 24-fiber MPO trunks and support interconnection from 40 Gigabit switch ports that have been remotely enabled as four 10 Gigabit independent paths. QSFP ports on the switch interface via a 1x3 MPO array to a 24 fiber trunk. This trunk connects to a 24 fiber (12 duplex LC) array at the other end, physically dividing the 10 gigabit paths to individual ports which provide LC connectivity.
This component set maintains fiber paths and polarity, and provide proper fiber mapping from transmit at one end to receive at the other over a total of twelve 10 Gigabit paths. All modules are compatible with HDEP chassis, frames and hardware, and feature a highly engineered, and highly effective, cable management system. Chassis are stackable and available in managed and unmanaged versions, supporting 144 fibers per RU in a usable cabling system.
24-Fiber High Density Array
1x3 MPO Array 24-Fiber Trunk
4 RU Chassis1 RU Chassis
24-Fiber MPO Trunk A-Polarity (Type A)
40G array 3 single row MPO to one
dual row 24 fiber MPO.
3
22
1 4
MPO MPO
MPO MPO
Fiber Module
8-Way MPO Adaptor Module
8-Way MPO Adaptor Module
For more information, visit commscope.com7
High Density Equipment Panel High Density 10 Gigabit Interconnect
Specifications
MPOptimate Performance: Factory measured maximum 0.35 dB insertion loss per module (LC-MPO) or 0.5 dB (MPO-MPO)
Traceable: Each module is uniquely identified and linked to factory measurement data
Standard Fiber Path: Compatible with TIA 568-C.0-2 draft standard for polarity method “A” trunks for 40 GbE
24-Fiber Trunk: Fiber path supports dual-fiber 10 Gigabit deployment via 40 Gigabit equipment connections (4x10Gbit paths per QSFP port)
Pinned Module: MPO alignment pins are maintained inside the module, reducing risk of damage
Module used in Pairs: Provides proper fiber map, polarity and location of MPO alignment pins
Flexible: Chassis enables superior cable management regardless of module type
Ordering Information
Number Component Part Number
1 1x3 MPO array MPG-1CNC240xxxF-NC
2HDEP Unmanaged Adapter Pack, MPO-MPO Aqua, (8x24F MPO ports)
N5AP-192MPOMMS
3 24-Fiber Trunk, Polarity A OM4 MPT-2C2CM40xxxF-FF
4 Array; one 24 fiber MPO to 12 duplex LC, OM4 MPL-1CLC240xxxF-NC
N/S Chassis 1 RU N5CHU-1RU
N/S Chassis 4 RU N5CHU-4RU
Note: x or xxx denotes length F = Feet and M = Meters and may be changed accordingly based on ordering preference
HD 10 Gigabit MPO-MPO Module
For more information, visit commscope.com8
High Density Equipment Panel 40 Gigabit Interconnect
Introduction
For 40 GbE applications, HDEP 40 Gigabit modules provide connection from standard 24-fiber MPO trunks with 24-fiber dual row connectors to three single row 8-fiber MPO connectors via breakout array assemblies. Each trunk supports three 8-Fiber 40 Gigabit links, utilizing all 24 fibers of the trunk without abandoning any fibers in the trunk. Each module supports distribution of twenty-four 40 Gigabit Ethernet links. When used with pairs of arrays they provide proper fiber mapping and polarity from transmit at one end of the link to receive at the other.
Modules are compatible with HDEP chassis, frames and hardware, which feature a simple, yet highly engineered cable management system. Chassis support six modules per rack unit (1 RU) or 48 total 40 Gigabit connections per RU.
24-Fiber MPO Trunk A-Polarity (Type A)
1x3 MPO Array
3
22
1 1
24-Fiber Trunk1x3 MPO Array
1x3 MPO Array
MPO MPO
MPO MPO
4 RU Chassis1 RU Chassis
Fiber Module
8-Way MPO Adaptor Module
8-Way MPO Adaptor Module
For more information, visit commscope.com9
High Density Equipment Panel 40 Gigabit Interconnect
Specifications
MPOptimate Performance: Compatible with MPOptimate trunks and patch cords. Maximum connection insertion loss 0.25dB for 24 fiber MPO
Standard Fiber Path: Compatible with TIA 568-C.0-2 draft standard for polarity method “A" trunks
24-Fiber Trunk: Fiber path supports 24-fiber deployment and 40 gigabit equipment connections. Each 24-fiber trunk supports three 8-fiber pathways without abandoning any trunk fibers
Module used in Pairs: Provides proper fiber map, polarity and location of MPO alignment pins
Flexible: System supports use of arrays or module and patch cords at either end of the trunk
Management capable: Managed modules and assemblies are available. Please contact CommScope for details
Note: Some proposed 100G transmission formats that employ 4X25G lanes employ this configuration
40 Gigabit MPO-MPO Module
Number Component Part Number
1 1x3 MPO Array MPG-1CNC240xxxF-NC
2Unmanaged Adapter Pack, MPO-MPO Aqua, 192 fibers (8, 24F MPO ports)
N5AP-192MPOMMS
3 24-Fiber Trunk, Polarity A OM4 MPT-2C2CM40xxxF-FF
N/S Chassis 1 RU N5CHU-1RU
N/S Chassis 4 RU N5CHU-4RU
Note: x or xxx denotes length F = Feet and M = Meters and may be changed accordingly based on ordering preference
Ordering Information
For more information, visit commscope.com10
High Density Equipment Panel 100 Gigabit Interconnect
Introduction
HDEP 100 Gigabit fiber modules provide connection from eight MPO trunks with 24-fiber dual-row connectors to eight 24-fiber MPO equipment or patch cords. Each module supports distribution of eight 100 gigabit Ethernet links when configured in a 10X10G transmission format.
When used in pairs with 24-fiber MPO patch cord pairs they provide proper fiber mapping from transmit at one end to receive at the other of the link.
Modules are compatible with HDEP chassis, frames and hardware, and feature a simple, yet highly engineered, cable management system. Modules snap easily into existing or newly installed HDEP chassis support six modules per rack unit (1RU) or a total of 48 MPO connections per RU. Each module is fully assembled at the factory and can reside in a chassis with 10, High Density 10, 40, and 100 GbE modules. Chassis are available in 1 and 4 rack unit (RU) versions.
24-fiber MPO Patch Cord
A-Polarity (Type A)
24-fiber MPO Patch Cord B-Polarity (Type B)
1 4
24 Fiber Trunk
24-Fiber MPO Trunk A-Polarity (Type A)3
MPO MPO
4 RU Chassis1 RU Chassis
22
MPO MPO
Fiber Module
8-Way MPO Adaptor Module
8-Way MPO Adaptor Module
For more information, visit commscope.com11
High Density Equipment Panel 100 Gigabit Interconnect
100 Gigabit MPO to MPO Modules
Ordering Information
Number Component Part Number
1 24-fiber MPO Patch Cord, Polarity A (Type A) MPT-1C2C240xxxF-NN
2Unmanaged Adapter Pack, MPO-MPO Aqua, 192 fibers (8, 24F MPO ports)
N5AP-192MPOMMS
3 24-Fiber Trunk, Polarity A OM4 MPT-2C2CM40xxxF-FF
4 24-Fiber MPO Patch Cord, Polarity B (Type B) MPF-1C2C240xxxF-NN
N/S Chassis 1 RU N5CHU-1RU
N/S Chassis 4 RU N5CHU-4RU
Note: x or xxx denotes length F = Feet and M = Meters and may be changed accordingly based on ordering preference
Specifications
MPOptimate Performance: Compatible with MPOptimate trunks and arrays
Standard Fiber Path: Compatible with TIA 568-C.0-2 draft standard for polarity method “A" trunks
24-Fiber Trunk: Up to eight 24-fiber MPO trunks per module
Patch Cords used in Pairs: Provides proper fiber map, polarity and location of MPO alignment pins
For more information, visit commscope.com12
High Density Equipment Panel 10 Gigabit Cross-Connect
Introduction
The 10 Gigabit Cross-Connect Solution, like all of the planned migration designs, begins with a 24-fiber optical trunk with a single MPO-type connector at each end. A trunk interface with the rear of an HDEP module that breaks out the trunk fibers into twelve duplex LC connections (24 fibers) at the front. This module resides in a highly efficient HDEP chassis which provides superior cable management for both the MPOs at the rear and LC patch cords at the front. HDEP chassis are stackable and available in 1 and 4 RU versions. Either chassis supports 72 duplex LCs (144 fibers) per rack unit (1RU).
Chassis can be populated all at once, or added to or upgraded a module at a time in the future. The HDEP chassis also supports High Density 10 Gigabit modules, as well as 40 and 100 GbE versions, allowing an upgrade path by changing only the components at the front and using existing and additional 24-fiber trunks at the rear.
Chassis can be cascaded to form a half or full cross-connect layout. Cross-Connection can be implemented via LCs to maintain single channel flexibility. (Note: Some cross-connect architectures are treated as engineered links, and available power budget must be verified.)
24-Fiber Trunk
LC Duplex A-B Patch CordLC Duplex
A-B Patch CordLC Duplex
A-B Patch Cord
2 2
1 11
4 4
24-Fiber MPO Trunk A-Polarity (Type A) 24-Fiber MPO Trunk A-Polarity (Type A)
MPO
LC Duplex LC Duplex
MPO
3 3
4 RU Chassis1 RU Chassis
24-Fiber MPO-LC Modules
24-Fiber MPO-LC Modules
24-Fiber MPO-LC Modules
24-Fiber MPO-LC Modules
NEED IMAGE
Fiber Module
For more information, visit commscope.com13
High Density Equipment Panel 10 Gigabit Cross-Connect
Specifications
MPOptimate Performance: Factory measured maximum measured 0.35 dB insertion loss per module
Traceable: Each module is uniquely identified and linked to factory measurement data
Standard Fiber Path: Compatible with TIA 568-C.0-2 draft standard for polarity method “A”
24-Fiber Trunk: Fiber path supports 24-fiber deployment
Pinned Module: MPO alignment pins are maintained inside the module, reducing risk of damage
Module used in Pairs: Provides proper fiber map, polarity and location of MPO alignment pins
Flexible: Chassis enables superior cable management and can be stacked in standard 19-inch racks or cabinets
Management capable: Managed modules and assemblies are available. Please contact CommScope for details
Ordering Information
Number Component Part Number
1 2-Fiber LC A-B Patch Cord FPCTB-MDLC-D-xM
2Unmanaged Module, LC-MPO Aqua, 24 fibers (1x24F MPO rear port), straight fiber path, Optimate performance
N5MP-24DLMR4AP (Right)
N5MP-24DLML4AP (Left)
3 24-Fiber Trunk, Polarity A OM4 MPT-2C2CM40xxxF-FF
4Unmanaged Module, LC-MPO Aqua, 24 fibers (1x24F MPO rear port), flipped fiber path, Optimate performance
N5MP-24DLMR4BP (Right)
N5MP-24DLML4AP (Left)
N/S Chassis 1 RU N5CHU-1RU
N/S Chassis 4 RU N5CHU-4RU
Note: x or xxx denotes length F = feet or M = meters and may be changed accordingly based on ordering preference
10 Gigabit LC-MPO Solution
For more information, visit commscope.com14
High Density Equipment Panel HD 10/40 Gigabit Cross-Connect
Introduction
HDEP High Density 10 Gigabit Fiber Modules also utilize 24-fiber MPO trunks and support connection from 40 Gigabit switch ports that have been remotely enabled as four 10 Gigabit independent paths. MPO-based QSFP ports at the switch interface with an array at one end of the trunk, and a break-out array divides these signals into duplex LC pairs at the other end.
Chassis and modules can be cascaded to form half or full Cross-Connect architectures. Cross-Connection can be implemented via LCs to maintain single channel flexibility. (Note: Some Cross-Connect architectures are treated as engineered links, and available power budget must be verified.)
MPO modules have eight MPO ports that support trunks and patchcords with MPOptimate performance levels. Each module supports distribution of eight 40 Gigabit Ethernet paths, each containing four duplex 10 Gigabit links. When deployed according to recommendations in this design guide, the system maintains fiber paths and polarity and provides proper fiber mapping from transmit at one end to receive at the other - over a total of twenty-four 10 Gigabit paths per module. All modules are compatible with HDEP chassis, frames and hardware, and feature a simple, yet highly effective, cable management system. Modules are 1/3 RU high, can snap easily into existing or newly installed HDEP chassis, and can be replaced by 40 and 100 GbE module in the future.
4 RU Chassis1 RU Chassis
24-Fiber Trunk
3 3
4
24-Fiber MPO Patch Cord B-Polarity (Type B)
24-Fiber MPO Trunk A-Polarity (Type A)
24-Fiber MPO Trunk A-Polarity (Type A)
40G array 3 single row MPO to one dual row 24 fiber MPO.
2 2
1
MPO MPO
MPO MPO
8-Way MPO Adaptor Module
8-Way MPO Adaptor Module
8-Way MPO Adaptor Module
8-Way MPO Adaptor Module
Fiber Module
24-Fiber High Density Array
5
1x3 MPO Array
For more information, visit commscope.com15
High Density Equipment Panel HD 10/40 Gigabit Cross-Connect
HD 10/40 Gigabit LC-MPO Cross-Connect Module
Number Component Part Number
1 1x3 MPO Array MPG-1CNC240xxxF-NC
2 HDEP Unmanaged Adapter Pack, MPO-MPO Aqua, (8x24F MPO ports) N5AP-192MPOMMS
3 24-Fiber Trunk, Polarity A OM4 MPT-2C2CM40xxxF-FF
4 24-Fiber MPO Patch Cord, Polarity B (Type B) MPF-1C1C240xxxF-NN
5 Array one 24 fiber MPO to 12 duplex LC, OM4 MPL-1CLC240xxxF-NC
N/S Chassis 1 RU N5CHU-1RU
N/S Chassis 4 RU N5CHU-4RU
Note: x or xxx denotes length F = Feet and M = Meters and may be changed accordingly based on ordering preference
Ordering Information
Specifications
MPOptimate Performance: 24 fiber MPOptimate connectors are specified at 0.25dB insertion loss
Standard Fiber Path: Compatible with TIA 568-C.0-2 draft standard for polarity method "A" (for 40 Gigabit Ethernet)
24-Fiber Trunk: Fiber path supports dual-fiber 10 Gigabit deployment via 40 Gigabit equipment connections (4x10Gbit paths per QSFP port)
Flexible: Chassis enables superior cable management and can be stacked in a standard 19-inch rack or cabinet
Modules Used in Pairs: Provides proper fiber map, polarity and location of MPO alignment pins
Management capable: Managed modules and assemblies are available. Please contact CommScope for details
For more information, visit commscope.com16
High Density Equipment Panel 40 Gigabit Cross-Connect
Introduction
For 40 GbE applications HDEP 40 Gigabit modules provide connection from standard 24-fiber MPO trunks with 24-fiber dual row connectors to three single row 8-fiber MPO connectors via breakout array assemblies. Each trunk supports three 8-Fiber 40 Gigabit links, utilizing all 24 fibers of the trunk without abandoning any fibers in the trunk. Each module supports distribution of twenty-four 40 Gigabit Ethernet links, for up to 144 links per RU.
When used with pairs of arrays they provide proper fiber mapping and polarity from transmit at one end of the link to receive at the other. (Note: Some Cross-Connect architectures are treated as engineered link and available power budget must be verified.)
Modules are compatible with HDEP chassis, frames and hardware, which feature a simple, yet highly engineered cable management system. Chassis support six modules per rack unit (1 RU) or 48 total 40 Gigabit connections per RU.
24-Fiber Trunk
4 RU Chassis1 RU Chassis
3 3
4
24-Fiber MPO Patch Cord B-Polarity (Type A)
24-Fiber MPO Trunk A-Polarity (Type A)
24-Fiber MPO Trunk A-Polarity (Type A)
40G array 3 single row MPO to one dual row 24 fiber MPO.
40G array 3 single row MPO to one dual
row 24 fiber MPO.
2 2
1 1
MPO MPO
MPO MPO
8-Way MPO Adaptor Module
8-Way MPO Adaptor Module
8-Way MPO Adaptor Module
8-Way MPO Adaptor Module
Fiber Module
For more information, visit commscope.com17
High Density Equipment Panel 40 Gigabit Cross-Connect
40 Gigabit MPO to MPO Cross-Connect Modules
Ordering Information
Number Component Part Number
1 1x3 MPO Array MPG-1CNC240xxxF-NC
2Unmanaged Adapter Pack, MPO-MPO Aqua, 192 fibers (8, 24F MPO ports)
N5AP-192MPOMMS
3 24-Fiber Trunk, Polarity A OM4 MPT-2C2CM40xxxF-FF
4 24-Fiber MPO Patch Cord, Polarity B (Type B) MPF-1C1C240xxxF-NN
N/S Chassis 1 RU N5CHU-1RU
N/S Chassis 4 RU N5CHU-4RU
Note: x or xxx denotes length F = Feet and M = Meters and may be changed accordingly based on ordering preference
Specifications
MPOptimate Performance: Compatible with MPOptimate trunks and patch cords. Maximum connection insertion loss 0.25dB for 24 fiber MPO
Standard Fiber Path: Compatible with TIA 568-C.0-2 draft standard for polarity method “A" trunks
24-Fiber Trunk: Fiber path supports 24-fiber deployment and 40 gigabit equipment connections. Each 24-fiber trunk supports three 8-fiber pathways without abandoning any trunk fibers
Module used in Pairs: Provides proper fiber map, polarity and location of MPO alignment pins
Flexible: System supports use of modules or module and patch cords at either end of the trunk
Management capable: Managed modules and assemblies are available. Please contact CommScope for details
Note: Some proposed 100G transmission formats that employ 4X25G lanes employ this configuration
For more information, visit commscope.com18
High Density Equipment Panel 100 Gigabit Cross-Connect
Introduction
HDEP 100 Gigabit fiber modules provide connection from eight MPO trunks with 24-fiber, dual-row connectors to eight 24-fiber MPO equipment or patch cords. Each module supports the distribution of eight 100 Gigabit Ethernet links when configured in a 10X10G transmission format. When used in pairs with 24-fiber MPO patch cord pairs they provide proper fiber mapping from transmit at one end to receive at the other of the link.
Modules can be cascaded to provide half or full cross-connect architectures. (Note: Some Cross-Connect architectures are treated as engineered links, and available power budget must be verified.)
Modules are compatible with HDEP chassis, frames and hardware, and feature a simple, yet highly engineered, cable management system. Chassis are available 1 and 4 rack unit (1RU and 4 RU) versions and support up to 48 x 100 Gigabit connections per RU. Each unit is fully assembled at the factory and can reside in a chassis with 10, High Density 10, 40 and 100 GbE modules to allow convenient, incremental upgrades.
24-Fiber Trunk
4 RU Chassis1 RU Chassis
3 3
2 2
MPO MPO
MPO MPO
8-Way MPO Adaptor Module
8-Way MPO Adaptor Module
8-Way MPO Adaptor Module
8-Way MPO Adaptor Module
24-Fiber MPO Patch Cord
B-Polarity (Type B)
24-Fiber MPO Patch Cord A-Polarity
(Type A)
24-Fiber MPO Patch Cord A-Polarity (Type A)
41 1
24-Fiber MPO Trunk A-Polarity (Type A) 24-Fiber MPO Trunk A-Polarity (Type A)
Fiber Module
www.commscope.comVisit our website or contact your local CommScope representative for more information.
© 2015 CommScope, Inc. All rights reserved.
MPOptimate and all trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services.
PS-318339.5-AE (12/15)
High Density Equipment Panel 100 Gigabit Cross-Connect
100 Gigabit MPO to MPO Modules
Ordering Information
Number Component Part Number
1 24-fiber MPO Patch Cord, Polarity A (Type A) MPT-1C2C240xxxF-NN
2Unmanaged Adapter Pack, MPO-MPO Aqua, 192 fibers (8, 24F MPO ports)
N5AP-192MPOMMS
3 24-Fiber Trunk, Polarity A OM4 MPT-2C2CM40xxxF-FF
4 24-Fiber MPO Patch Cord, Polarity B (Type B) MPF-1C1C240xxxF-NN
N/S Chassis 1 RU N5CHU-1RU
N/S Chassis 4 RU N5CHU-4RU
Note: x or xxx denotes length F = Feet and M = Meters and may be changed accordingly based on ordering preference
Specifications
MPOptimate Performance: 24 fiber MPOptimate connections are specified at 0.25dB insertion loss
Standard Fiber Path: Compatible with TIA 568-C.0-2 draft standard for polarity method "A" trunks
24-Fiber Trunk: Up to eight 24-fiber MPO trunks per module
Patch Cords and Modules used in Pairs: Provide proper fiber map, polarity and location of MPO alignment pins
Management capable: Managed modules and assemblies are available. Please contact CommScope for details