Post on 12-Apr-2016
description
SAP Note
Header Data
Symptom
Connection problems occur when printing remotely from the SAP system.
Other Terms
..
Reason and Prerequisites
Solution
Only change the following profile parameter after consulting with SAP Support.
rspo/tcp/timeout/connect
This parameter limits the set up time for the connection to remote printers when using access methods 'U' and 'S'. If the remote computer does not respond within this time, the print request is put on hold and the printer is blocked for some time (rspo/tcp/retrytime). Default value: 10 seconds Note: Before you increase this value, you should consider handling the connection to problematic printers using the host spool. An increase of the connection time reduces the performance of the overall system!
rspo/tcp/timeout/read and rspo/tcp/timeout/write
With these parameters, you set the maximum time for sending an individual packet to and receiving an individual packet from the remote printer. This period should be longer than the period for the connection setup. Default value: 20 seconds Note: Before you increase this value, you should consider handling the connection to problematic printers using the host spool. An increase of the connection time will reduce the performance of the overall system!
rspo/tcp/retries
This parameter determines the number of connection attempts to remote printers. If this number is reached, the status of the request is set to 'Error'. Default value: 3
rspo/tcp/retrytime
With this parameter, you set the time interval between unsuccessful connection attempts. Default value: 300 seconds
rspo/lpq/temp_disable_slow
If a lpstat or lpq command for the host spool or a remote printer requires more time than defined here, this printer is regarded as broken and is blocked for some time (rspo/lpq/temp_disable_time). This reduces the load of the entire spool system caused by computers that are not answering. With value 0 you can deactivate this monitoring. Default value: 30 seconds Note: This parameter does not influence the time which restricts the execution of lpq or lpstat. For access method 'U' and 'S', it is restricted by rspo/tcp/timeout/connect or .../read. For the other access methods, there is no time limit. There is only a retroactive response to long execution times.
rspo/lpq/temp_disable_time
The printer is blocked for this time, if the response time exceeds the value defined with rspo/lpq/temp_disable_slow. Default value: 300 seconds
rspo/lpq/warn_time
If a lpq or lpstat command requires more time than the predefined time, a warning is written to the
20924 - Parameter settings for remote printing
Version 9 Validity: 21.02.2006 - active Language English
Released On 21.02.2006 23:33:45
Release Status Released for Customer
Component BC-CCM-PRN-SPO Spool System
Priority Recommendations / Additional Info
Category Consulting
syslog. This message informs you about the occurred performance problem. If you set the parameter to 0 and this test is not carried out. Default value: 15 Seconds.
Validity
This document is not restricted to a software component or software component version
References
This document refers to:
SAP Notes
This document is referenced by:
SAP Notes (1)
33873 What do the semaphores mean?
33873 What do the semaphores mean?