The Classic Series...Meet the Noris Medical Classic Legacy Series Noris Medical implant systems are...

18
The Classic Series NORIS Medical Dental Implant Solutions Stability & Accuracy Above All Tuff TT Tuff Pro Tuff Onyx Cortical

Transcript of The Classic Series...Meet the Noris Medical Classic Legacy Series Noris Medical implant systems are...

Page 1: The Classic Series...Meet the Noris Medical Classic Legacy Series Noris Medical implant systems are designed with the anatomy of the bone in mind to achieve optimal clinical and esthetic

The Classic Series

NORIS MedicalDental Implant Solutions

Stability & Accuracy Above All

Tuff TT

Tuff ProTuff

Onyx

Cortical

Page 2: The Classic Series...Meet the Noris Medical Classic Legacy Series Noris Medical implant systems are designed with the anatomy of the bone in mind to achieve optimal clinical and esthetic

Meet the Noris MedicalClassic Legacy Series

Noris Medical implant systems are designed with the anatomy of the bone in mind to achieve optimal clinical and esthetic results

This series includes our Vici Implants Tuff-TT, Cortical, and Tuff-Pro. (Vic stand for Vicissitude - a change or variation, which defines our implants perfectly)

All implants in the series are designed and engineered to bring a solution to a wide range of patient needs, offering a unique portfolio of materials and surfaces.

Our Tuff and Onyx dental implants offer versatile solutions to a variety of clinical indications, enabling simple treatment and maximum flexibility:

ONE SYSTEM - WITH ONE KIT - FOR MULTIPLE INDICATIONS

Page 3: The Classic Series...Meet the Noris Medical Classic Legacy Series Noris Medical implant systems are designed with the anatomy of the bone in mind to achieve optimal clinical and esthetic

Tuff Implant When the going gets tough the TUFF gets going.With versatile application capabilities the TUFF has three thread zones. Tuff implants have been uniquely designed according to the anatomy of the bone structure.

The Apical V-shape thread zone enables self-tapping.

The Medullary zone square type thread is used for compressing cancellous bone and helping achieve maximum BIC.

The micro thread of the Crestal zone adds stability and prevents Crestal bone loss.

The TUFF is tough with its grade 5 titanium structure and RBM surface. With diameters range of 3.3-6mm and lengths of 6-18mm no case is tough enough for the TUFF.

Material: Titanium (Ti6Al4V ELI)

Treatment: RBM

The micro thread at the upper zone adds stability and prevents crestal bone loss

The middle zone square type thread is used for compressing cancellous bone and helps achievement of maximum BIC

The lower V-shape thread zone enables self-tapping

Available in two neck textures versions: Machined surface or RBM treated surface.

Benefits• Wide dimensions range, from diameters

of 3.3-6mm to lengths of 6-25mm.• Unified prosthetic platform for all implants.• Suitable for all bone types.• Excellent retention for immediate loading.• Tapered body for better bone preservation.

• Self-tapping.

Clinical ChallengeCan be a solution for all bone types.

Page 4: The Classic Series...Meet the Noris Medical Classic Legacy Series Noris Medical implant systems are designed with the anatomy of the bone in mind to achieve optimal clinical and esthetic

* The proposed procedure is only a recommendation and should not replace the doctor's judgment. The implants may be placed in immediate function when good primary stability (above 35 Ncm) has been achieved and with appropriate occlusal loading.

* Implant Carrier removal After the osteotomy preparation, the implant should be inserted with the aid of the implant carrier. The implant should be initially stabilized by a few threads and then the carrier should be removed. Further insertion of the implants will be done with the appropriate driver.

* Implant hexagon During implant insertion, the straight part of the hexagon should be located toward the angulation needed, in order to provide optimal prosthetic emergence.

Drilling Speed (RPM) 1200- 1500

900- 1200

500- 700

500- 700

400-700

400-700

400-600

400-600

400-600

400-600

400-600

300-500

400-600

300-500

200-500

Drill Diameter)Existing Hole Diameters(

ø2.0 ø2.8 )ø2.0(

ø2.8 ø3.2)ø2.8(

(ø3.2) )ø2.8(

ø3.2 )ø2.8(

(ø3.2) )ø2.8(

ø3.65 )ø3.2( )ø2.8(

ø3.65 ø4.2 )ø3.65(

ø5.0 )ø4.2(

)ø3.65(

ø4.2 ø5.2 )ø4.2(

ø6.0 )ø5.2( )ø4.2(

Drill Sequence* Bone type D1, D2

L 1/3

L 2/3

L

ø3.3 ø3.3 ø3.3 ø3.75 ø3.75 ø4.2 ø4.2 ø5.0 ø5.0 ø6.0 ø6.0

Torque Too high   Further Drilling Sequence Insert Implant ?

? ? ?? ? ?

Drilling Speed (RPM) 1200- 1500

900- 1200

500- 700

400- 700

400- 600

400- 600

300- 500

Drill Diameter ø2.0 ø2.8 ø3.2 ø3.65 ø4.2 ø5.2

Drill Sequence* Bone type D3, D4

L 1/3

L 2/3

L

ø3.3 ø3.75 ø4.2 ø5.0 ø6.0

Tuff Implant

Surgical Drilling Protocol

Page 5: The Classic Series...Meet the Noris Medical Classic Legacy Series Noris Medical implant systems are designed with the anatomy of the bone in mind to achieve optimal clinical and esthetic

Tuff Implant

Implants Ø D (mm) Ø D0 (mm) Ø D1 (mm) L (mm) RBM Treated Neck Machined Neck

3.3 1.5 2.6

8 NM-F3308 NMSF3308

10 NM-F3310 NMSF3310

11.5 NM-F3311 NMSF3311

13 NM-F3313 NMSF3313

16 NM-F3316 NMSF3316

3.75 1.8 3.1

6 NM-F3706 NMSF3706

8 NM-F3708 NMSF3708

10 NM-F3710 NMSF3710

11.5 NM-F3711 NMSF3711

13 NM-F3713 NMSF3713

16 NM-F3716 NMSF3716

18 NM-F3718 NMSF3718

4.2 2.1 3.5

6 NM-F4206 NMSF4206

8 NM-F4208 NMSF4208

10 NM-F4210 NMSF4210

11.5 NM-F4211 NMSF4211

13 NM-F4213 NMSF4213

16 NM-F4216 NMSF4216

18 NM-F4218 NMSF4218

20 NM-F4220 NMSF4220

22 NM-F4222 NMSF4222

25 NM-F4225 NMSF4225

5.0 2.7 4.5

6 NM-F5006 NMSF5006

8 NM-F5008 NMSF5008

10 NM-F5010 NMSF5010

11.5 NM-F5011 NMSF5011

13 NM-F5013 NMSF5013

16 NM-F5016 NMSF5016

6.0 3.8 5.2

6 NM-F6006 NMSF6006

8 NM-F6008 NMSF6008

10 NM-F6010 NMSF6010

11.5 NM-F6011 NMSF6011

13 NM-F6013 NMSF6013

16 NM-F6016 NMSF6016

 Cover Screw Included with all implants   

NM-S5023

Page 6: The Classic Series...Meet the Noris Medical Classic Legacy Series Noris Medical implant systems are designed with the anatomy of the bone in mind to achieve optimal clinical and esthetic

Tuff Pro ImplantNoris “TUFF-Pro» is one of our Classic Vici implants - a series of implants that one can only win with!This line of implants was uniquely designed and planned with the constant desire to improve our classic implants and customize it for your clinical needs.

• The unique feature of the TUFF-Pro, the 2mm machined neck, has many advantages:

• The implant can be placed immediately into extraction sockets while keeping the machined collar supracrestal. This can potentially allow the maintenance of the gingival contour and help Protect outer gingival appearance and architecture.

• The implant Supercrestally to subcrestal. The 2mm neck will help Protect and support the soft tissue!

• The implant can be placed in areas of non-resorbing Basal Bone. For example, taking advantage of the nasopalatine canal as a potential implant site. Thus providing Protection and support for wide span prosthesis, and taking advantage of uneven ridges.

• And many more advantages…

Material: Titanium (Ti6Al4V ELI)

Treatment: RBM2.43mm hexagon smooth neck to prevent bacterial adhesion

Thread is used for compressing cancellous bone and helps achievement of maximum BIC

V-shape thread zone

BenefitsThe unique feature of the TUFF-Pro is the 2mm machined neck:• Can be placed immediately into extraction sockets

while keeping the machined collar supracrestal. • Allow the maintenance of the gingival contour

and help protect outer gingival appearance and architecture

• Can be placed supercrestally, by design, taking advantage of the machined collar.

• The 2mm neck will help protect and support the soft tissue!

• Can be placed in areas of non-resorbing basal bone. • Providing protection and support for wide span

prosthesis, and taking advantage of uneven ridges.

Clinical ChallengeCan provide a solution of combination ridge/basal bone placement cases.

Page 7: The Classic Series...Meet the Noris Medical Classic Legacy Series Noris Medical implant systems are designed with the anatomy of the bone in mind to achieve optimal clinical and esthetic

Tuff Pro Implant

* The proposed procedure is only a recommendation and should not replace the doctor's judgment. The implants may be placed in immediate function when good primary stability (above 35 Ncm) has been achieved and with appropriate occlusal loading.

* Implant Carrier removal After the osteotomy preparation, the implant should be inserted with the aid of the implant carrier. The implant should be initially stabilized by a few threads and then the carrier should be removed. Further insertion of the implants will be done with the appropriate driver.

* Implant hexagon During implant insertion, the straight part of the hexagon should be located toward the angulation needed, in order to provide optimal prosthetic emergence.

Drilling Speed (RPM) 1200- 1500

900- 1200

500- 700

400- 700

400- 600

400- 600

Drill Diameter ø2.0 ø2.8 ø3.2 ø3.65 ø4.2

Drill Sequence* Bone type D3, D4

1/3 L

2/3 L

L

ø3.3 ø3.75 ø4.2 ø5.0

Drilling Speed (RPM) 1200- 1500

900- 1200

500- 700

500- 700

400-700

400-700

400-600

400-600

400-600

400-600

400-600

300-500

Drill Diameter)Existing Hole Diameters(

ø2.0 ø2.8 )ø2.0(

ø2.8 ø3.2)ø2.8(

(ø3.2) )ø2.8(

ø3.2 )ø2.8(

(ø3.2) )ø2.8(

ø3.65 )ø3.2( )ø2.8(

ø3.65 ø4.2 )ø3.65(

ø5.0 )ø4.2(

)ø3.65(

Drill Sequence* Bone type D1, D2

1/3 L

2/3 L

L

ø3.3 ø3.3 ø3.3 ø3.75 ø3.75 ø4.2 ø4.2 ø5.0 ø5.0

Torque Too high   Further Drilling Sequence Insert Implant ?

? ? ?? ?

Surgical Drilling Protocol

Page 8: The Classic Series...Meet the Noris Medical Classic Legacy Series Noris Medical implant systems are designed with the anatomy of the bone in mind to achieve optimal clinical and esthetic

Implants Ø D (mm) Ø D0 (mm) Ø D1 (mm) L (mm) Item

3.3 1.5 2.6

8 NMAF3308

10 NMAF3310

11.5 NMAF3311

13 NMAF3313

16 NMAF3316

3.75 1.8 3.1

8 NMAF3708

10 NMAF3710

11.5 NMAF3711

13 NMAF3713

16 NMAF3716

4.2 2.1 3.5

6 NMAF4206

8 NMAF4208

10 NMAF4210

11.5 NMAF4211

13 NMAF4213

16 NMAF4216

5.0 2.7 4.5

6 NMAF5006

8 NMAF5008

10 NMAF5010

11.5 NMAF5011

13 NMAF5013

16 NMAF5016

 Cover Screw Included with all implants   

NM-S5023

Tuff Pro Implant

Page 9: The Classic Series...Meet the Noris Medical Classic Legacy Series Noris Medical implant systems are designed with the anatomy of the bone in mind to achieve optimal clinical and esthetic

Tuff TT Implant With their three thread zones, Tuff implants have been uniquely designed according to the anatomy of the bone structure. The micro thread on the upper zone adds stability and helps prevents crestal bone loss.• The middle zone square type thread is used for compressing cancellous bone and helping

achieve maximum BIC.• The lower V-shape thread zone enables self-tapping.• The TUFF-TT Comes with Wide dimensions range, from diameters of 6-4.2 mm to lengths of

20-6 mm, providing excellent retention for immediate loading. The taper top of the TT will allow the top of the alveolar crest to heal around the implant and provide a platform shift.

Material: Titanium (Ti6Al4V ELI)

Treatment: RBM

The micro thread at the upper zone adds stability and prevents crestal bone loss

The middle zone square type thread is used for compressing cancellous bone and helps achievement of maximum BIC

The lower V-shape thread zone enables self-tapping

Benefits• Share the same three-thread zone concept as Tuff

implants.• Converging coronal shape and allows platform

switch technology to prevent crestal bone loss.• Compressing cancellous bone and helping achieve

maximum bic.• Providing excellent retention for immediate loading• Unified prosthetic platform for all implants• Two starts for main thread

Clinical ChallengeCan be a solution for all bone types.

Page 10: The Classic Series...Meet the Noris Medical Classic Legacy Series Noris Medical implant systems are designed with the anatomy of the bone in mind to achieve optimal clinical and esthetic

Tuff TT Implant

(Drilling Speed (RPM 1200- 1500

900- 1200

500- 700

400- 700

400- 600

400- 600

300- 500

Drill Diameter ø2.0 ø2.8 ø3.2 ø3.65 ø4.2 ø5.2

*Drill SequenceBone type D3, D4

L 1/3

L 2/3

L

ø3.3 ø3.75 ø4.2 ø5.0 ø6.0

* The proposed procedure is only a recommendation and should not replace the doctor's judgment. The implants may be placed in immediate function when good primary stability (above 35 Ncm) has been achieved and with appropriate occlusal loading.

* Implant Carrier removal After the osteotomy preparation, the implant should be inserted with the aid of the implant carrier. The implant should be initially stabilized by a few threads and then the carrier should be removed. Further insertion of the implants will be done with the appropriate driver.

* Implant hexagon During implant insertion, the straight part of the hexagon should be located toward the angulation needed, in order to provide optimal prosthetic emergence.

(Drilling Speed (RPM 1200- 1500

900- 1200

500- 700

500- 700

400-700

400-700

400-600

400-600

400-600

400-600

400-600

300-500

400-600

300-500

200-500

Drill Diameter)Existing Hole Diameters(

ø2.0 ø2.8 )ø2.0(

ø2.8 ø3.2)ø2.8(

(ø3.2) )ø2.8(

ø3.2 )ø2.8(

(ø3.2) )ø2.8(

ø3.65 )ø3.2( )ø2.8(

ø3.65 ø4.2 )ø3.65(

ø5.0 )ø4.2(

)ø3.65(

ø4.2 ø5.2 )ø4.2(

ø6.0 )ø5.2( )ø4.2(

*Drill SequenceBone type D1, D2

L 1/3

L 2/3

L

ø3.3 ø3.3 ø3.3 ø3.75 ø3.75 ø4.2 ø4.2 ø5.0 ø5.0 ø6.0 ø6.0

Torque Too high   Further Drilling Sequence Insert Implant ?

? ? ?? ? ?

Surgical Drilling Protocol

Tuff TT Implant

Page 11: The Classic Series...Meet the Noris Medical Classic Legacy Series Noris Medical implant systems are designed with the anatomy of the bone in mind to achieve optimal clinical and esthetic

implants Ø D (mm) Ø D0 (mm) Ø D1 (mm) L (mm) Item

4.2 2.1 3.5

6 NM-F4306

8 NM-F4308

10 NM-F4310

11.5 NM-F4311

13 NM-F4313

16 NM-F4316

18 NM-F4318

20 NM-F4320

5.0 2.7 4.2

6 NM-F5106

8 NM-F5108

10 NM-F5110

11.5 NM-F5111

13 NM-F5113

16 NM-F5116

6.0 3.7 5.0

6 NM-F6106

8 NM-F6108

10 NM-F6110

11.5 NM-F6111

13 NM-F6113

 Cover Screw Included with all implants   

NM-S5023

Tuff TT Implant

Page 12: The Classic Series...Meet the Noris Medical Classic Legacy Series Noris Medical implant systems are designed with the anatomy of the bone in mind to achieve optimal clinical and esthetic

Onyx Implant Onyx implants are classic implants specially designed for treatments involving placement in type I and type II bone.

The micro thread at the upper zone adds stability and prevents crestal bone loss.

Material: Titanium (Ti6Al4V ELI)

Treatment: RBM

Benefits• 2.43mm hexagon.

• Wide dimensions range, from diameters of 3.3-6mm to lengths of 6-16mm.

• Unified prosthetic platform for all implants.

• High initial stability.

Clinical ChallengeA solution for all bone types.

The micro thread at the upper zone adds stability and prevents crestal bone loss

Cylinder shape

Fine threads

Page 13: The Classic Series...Meet the Noris Medical Classic Legacy Series Noris Medical implant systems are designed with the anatomy of the bone in mind to achieve optimal clinical and esthetic

Onyx Implant

(Drilling Speed (RPM 1200- 1500

900- 1200

500- 700 400-700

200-500

400-600

200-500

400-600

200-500

300-500

200-500

Drill Diameter ø2.0 ø2.8 ø3.2 ø3.75 ø3.65 ø3.75 ø4.2 ø5-6 ø5.2 ø5-6

*Drill SequenceBone type D1, D2

L 1/3

L 2/3

L

ø3.3 ø3.75 ø4.2 ø5.0 ø6.0

(Drilling Speed (RPM 1200- 1500

900- 1200

500- 700 400-700

400-600

400-600

300-500

Drill Diameter ø2.0 ø2.8 ø3.2 ø3.65 ø4.2 ø5.2

*Drill SequenceBone type D3, D4

L 1/3

L 2/3

L

ø3.3 ø3.75 ø4.2 ø5.0 ø6.0

* The proposed procedure is only a recommendation and should not replace the doctor's judgment. The implants may be placed in immediate function when good primary stability (above 35 Ncm) has been achieved and with appropriate occlusal loading.

* Implant Carrier removal After the osteotomy preparation, the implant should be inserted with the aid of the implant carrier. The implant should be initially stabilized by a few threads and then the carrier should be removed. Further insertion of the implants will be done with the appropriate driver.

* Implant hexagon During implant insertion, the straight part of the hexagon should be located toward the angulation needed, in order to provide optimal prosthetic emergence.

Surgical Drilling Protocol

Page 14: The Classic Series...Meet the Noris Medical Classic Legacy Series Noris Medical implant systems are designed with the anatomy of the bone in mind to achieve optimal clinical and esthetic

Onyx Implant

Implants Ø D (mm) Ø D1 (mm) L (mm) Item

3.3 2.4

8 NM-G3308

10 NM-G3310

11.5 NM-G3311

13 NM-G3313

16 NM-G3316

3.75 2.8

6 NM-G3706

8 NM-G3708

10 NM-G3710

11.5 NM-G3711

13 NM-G3713

16 NM-G3716

4.2 3.2

6 NM-G4206

8 NM-G4208

10 NM-G4210

11.5 NM-G4211

13 NM-G4213

16 NM-G4216

5.0 4.0

6 NM-G5006

8 NM-G5008

10 NM-G5010

11.5 NM-G5011

13 NM-G5013

16 NM-G5016

6.0 5.0

6 NM-G6006

8 NM-G6008

10 NM-G6010

11.5 NM-G6011

13 NM-G6013

 Cover Screw Included with all implants   

NM-S5023

Page 15: The Classic Series...Meet the Noris Medical Classic Legacy Series Noris Medical implant systems are designed with the anatomy of the bone in mind to achieve optimal clinical and esthetic

Cortical The unique form of the Cortical implant supports bi-cortical anchorage and increases BIC.

The result: exceptionally strong retention and primary implant stability.

The Cortical system can be used in extraction sites for immediate implantation.

Cortical is available in different sizes to suit any implantation site.

Material: Titanium (Ti6Al4V ELI)

Treatment: RBM

.

2.43mm hexagon, smooth neck to prevent bacterial adhesion

RBM treated surface

Sharp and deep threads, orthogonal to the occlusion load, for remarkable stability

Benefits• Developed after many years of combined

experience especially for immediate loading in conditions of insufficient bone.

• Intended for cases with narrow ridges of sockets with less than 4 walls.

• The threads are orthogonal to the occlusion load.

• Greater resistance to the lateral mechanical stress.

Clinical ChallengeA solution for narrow ridges, combination ridge anatomy and for immediate extraction sites.

Page 16: The Classic Series...Meet the Noris Medical Classic Legacy Series Noris Medical implant systems are designed with the anatomy of the bone in mind to achieve optimal clinical and esthetic

Cortical Implant

Drilling Speed (RPM) 1200- 1500

900- 1200

500- 700

200-500

400-700

200-500

Drill Diameter ø2.0 ø2.8 ø3.2 ø3.2 ø3.65

Drill Sequence* Bone type D1, D2

1/3 L

2/3 L

L

ø4.0 ø4.0 ø5.0 ø5.0 ø6.0

Drilling Speed (RPM) 1200- 1500

900- 1200

Drill Diameter ø2.0

Drill Sequence* Bone type D3, D4

L 1/3

L 2/3

L

ø4.0 ø5.0 ø6.0

* The proposed procedure is only a recommendation and should not replace the doctor's judgment. The implants may be placed in immediate function when good primary stability (above 35 Ncm) has been achieved and with appropriate occlusal loading.

* Implant Carrier removal After the osteotomy preparation, the implant should be inserted with the aid of the implant carrier. The implant should be initially stabilized by a few threads and then the carrier should be removed. Further insertion of the implants will be done with the appropriate driver.

* Implant hexagon During implant insertion, the straight part of the hexagon should be located toward the angulation needed, in order to provide optimal prosthetic emergence.

? ?

Torque Too high Further Drilling Sequence Insert Implant ?

Surgical Drilling Protocol

Page 17: The Classic Series...Meet the Noris Medical Classic Legacy Series Noris Medical implant systems are designed with the anatomy of the bone in mind to achieve optimal clinical and esthetic

Cortical Implant

L

L2

D

2.42

4

3.75

4

L1

1.6

Cortical

L

L2

D

2.42

4

3.75

4

L1

1.6

Cortical

Implants Ø D (mm) L (mm) L1 (mm) L2 (mm) Item

4.0

10 4.5 5.5 NM-M4010

11.5 4.7 6.8 NM-M4011

13 5 8 NM-M4013

16 6 10 NM-M4016

18 7 11 NM-M4018

20 7.5 12.5 NM-M4020

5.0

8 4.1 3.9 NM-M5008

10 4.5 5.5 NM-M5010

11.5 4.7 6.8 NM-M5011

13 5 8 NM-M5013

16 6 10 NM-M5016

6.0

8 4.1 3.9 NM-M6008

10 4.5 5.5 NM-M6010

11.5 4.7 6.8 NM-M6011

13 5 8 NM-M6013

16 6 10 NM-M6016

Cover Screw Included with all implants

NM-S5023

Only CE Approved

Page 18: The Classic Series...Meet the Noris Medical Classic Legacy Series Noris Medical implant systems are designed with the anatomy of the bone in mind to achieve optimal clinical and esthetic

norismedical.comNORIS MedicalDental Implant Solutions

We Can Make You