V.I. InspectionsPage 1 of 10
21:21 August 24, 2018
#1 2014 N 143rd St, Seattle. #2 Paint peeling in front steps.
#3 Rot present in front entry step riser trim. #4 Gap at front porch edge needs to be sealed.
#5 Vegetation in contact with house should be trimmed
back.
#6 Paint peeling in trim work.
Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.
V.I. InspectionsPage 2 of 10
21:21 August 24, 2018
#7 Paint unfinished in siding system. #8 Rain barrels need to be maintained against overflow
onto siding.
#9 Paint unfinished. #10 Fence is weathered.
#11 SE basement window pane cracked. #12 Downspouts drain too close to foundation.
Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.
V.I. InspectionsPage 3 of 10
21:21 August 24, 2018
#13 Siding install unfinished under NE bump out. #14 Paint unfinished in sections of trim work.
#15 No handrail for basement access steps. #16 Siding seams line up vertically on lower N siding.
#17 Caulking unfinished in lower N siding. #18 Pest cage will need to be maintained from lint build
up over time.
Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.
V.I. InspectionsPage 4 of 10
21:21 August 24, 2018
#19 Oil tank for furnace located in backyard. #20 Heavy displacement in driveway retaining wall.
#21 Soil contact at SW basement window sill. #22 Debris build up in valley system.
#23 Minor moss build up on roof surface. #24 No kick out flashing installed at lower roof connection
to siding.
Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.
V.I. InspectionsPage 5 of 10
21:21 August 24, 2018
#25 Paint peeling in fascia system. #26 SE gutter needs to be cleaned.
#27 NE gutter is not installed. #28 Possible asbestos tape present in the living room
heat register.
#29 Stairs to second floor are very steep, normal for age
of house.
#30 Active knob and tube wiring visible in attic.
Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.
V.I. InspectionsPage 6 of 10
21:21 August 24, 2018
#31 Minor roof debris build up in attic insulation. #32 Lower cabinet base under kitchen island partially
detached.
#33 Original sewer line should be fully sealed. #34 Cross bracing not installed where floor joist has been
cut under bathroom.
#35 Rot present in sub floor material under N end of
bathroom.
#36 Form boards still installed along SE foundation wall.
Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.
V.I. InspectionsPage 7 of 10
21:21 August 24, 2018
#37 Frass build up in SE corner of basement crawl space
indicates past insect intrusion.
#38 Cover plate missing from furance control box, live
wiring (safety).
#39 Furnace flue partially detached from chimney. #40 Abandoned wiring around electric panel should be
removed.
#41 Minor cracks in basement floor. #42 Staining along SW foundation, visible in basement,
indicates water intrusion in wet season.
Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.
V.I. InspectionsPage 8 of 10
21:21 August 24, 2018
#43 Garage. #44 Vegetation in contact with W wall should be removed.
#45 Open gaps between siding and framing over garage
door, water intrusion spot.
#46 Roof covered in moss, cannot inspect.
#47 Tar patchwork at garage roof connection to house. #48 Roof covered in moss, cannot inspect.
Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.
V.I. InspectionsPage 9 of 10
21:21 August 24, 2018
#49 Rot in end pieces of roof framing in SW and NE
corners.
#50 Particle board siding has higher failure rate.
#51 Rot in sections of roof framing of garage. #52 N section of garage structure being removed.
#53 Gutters not installed. #54 Siding installed around window, higher potential for
water intrusion.
Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.
V.I. InspectionsPage 10 of 10
21:21 August 24, 2018
#55 Sections of particle board siding have failed. #56 Rot in roof framing along NE edge.
#57 Roof framing undersized for slope and span. #58 Cracks with displacement in W retaining wall in
garage.
Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.