936.
1956
/e Su
bject
to alt
eratio
n.Triple-Band Combiner
Pass bandBand 1 (GSM 900) 880 960 MHzBand 2 (GSM 1800) 1710 1880 MHzBand 3 (UMTS) 1920 2170 MHz
Insertion lossPort 1 Port 4 < 0.2 dB ( 880 960 MHz)Port 2 Port 4 < 0.3 dB (1710 1880 MHz)Port 3 Port 4 < 0.3 dB (1920 2170 MHz)
IsolationPort 1 Port 2 > 50 dB ( 880 960 / 1710 1880 MHz)Port 1 Port 3 > 50 dB ( 880 960 / 1920 2170 MHz)Port 2 Port 3 > 50 dB (1710 1880 / 1920 2170 MHz)
VSWR < 1.2 (880 960 / 1710 1880 / 1920 2170 MHz)Impedance 50 Input power
Band 1 < 240 WBand 2 < 240 WBand 3 < 240 W
Intermodulation products < 160 dBc (3rd order; with 2 x 20 W)Temperature range 40 ... +60 CConnectors 7-16 femaleApplication Indoor or outdoor (IP 66)Special features External DC stop available as an accessory Built-in DC stop between ports 1 and 4, ports 2 and 4
DC by-pass between all ports (max. 2500 mA) DC by-pass between ports 3 and 4 (max. 2500 mA)Built-in lightning protection (3 kA, 10/350 s pulse)
Mounting Wall mounting: With 4 screws (max. 8 mm diameter)Mast mounting: With additional clamp set
Weight 4.7 kg 9.4 kg 4.7 kg 9.4 kgPacking size 363 x 304 x 145 mm 363 x 304 x 198 mm 363 x 304 x 145 mm 363 x 304 x 198 mmDimensions (w x h x d) 251 x 318 x 60 mm 251 x 318 x 127 mm 251 x 318 x 60 mm 251 x 318 x 127 mm
(including mounting brackets)
793 425, 793 426, 782 10245, 782 10246 Page 1 of 2KATHREIN-Werke KG . Anton-Kathrein-Strae 1 3 . PO Box 10 04 44 . D-83004 Rosenheim . Germany . Telephone +49 8031 1 84-0 . Fax +49 8031 1 84-9 91Internet: http://www.kathrein.de
880 960 MHzGSM 900
1710 1880 MHzGSM 1800
1920 2170 MHzUMTS
793 425, 782 10245Single Unit
793 426, 782 10246Double Unit
Port 2
Port 1
Port 3
Port 4
Single Unit 793 425 Double Unit 793 426 (only 1 unit shown)
Single Unit 782 10245 Double Unit 782 10246 (only 1 unit shown)
Type No. 793 425 793 426 782 10245 782 10246Single Unit Double Unit Single Unit Double Unit
Technical Data
Designed for co-siting purposes Enables feeder sharing Can be used as a combiner near the BTS or
in a reciprocal function near the antenna Suitable for indoor or outdoor applications Wall or mast mounting Available as a single unit, or for XPol antennas
as a double unit Built-in lightning protection
793 425: Single unit, DC by-pass between all ports External DC stop available as an accessory
793 426: Double unit, DC by-pass between all portsExternal DC stop available as an accessory
782 10245: Single unit, DC by-pass between ports 3 and 4Built-in DC stop between ports 1 and 4, ports 2 and 4
782 10246: Double unit, DC by-pass between ports 3 and 4Built-in DC stop between ports 1 and 4, ports 2 and 4
126.642
1261
604229
317.
728
7.7
247.
220
4
212.5109
30
8.5
251245
6498
83
Seria
l no.
Type
no.
7934
25
Port 1GSM 900880960 MHZ
Port 2GSM 180017101880 MHZ
Port 3UMTS
19202170 MHZ
Port 4
COMMON
880960 / 17101880
19202170 MHZ
Port 1 Port 2 Port 3
Port 4
936.
1956
/e Su
bject
to alt
eratio
n.
1920 2170
0
10
20
30
40
50
60
70
80
90
100500 700 900 1100 1300 1500 1700 1900 2100 2300 2500
Atte
nuat
ion/
dB
Frequency/MHz
Port 1 Port 4 Port 2 Port 4Diagram I Port 3 Port 4
1710 1880
880 960
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0500 700 900 1100 1300 1500 1700 1900 2100 2300 2500
Atte
nuat
ion/
dB
Frequency/MHz
Diagram II Port 1 Port 4 Port 2 Port 4 Port 3 Port 4
880 960 1920 2170
1710 1880
Typical Attenuation Curves
Triple-Band Combiner880 960 MHz
GSM 9001710 1880 MHz
GSM 18001920 2170 MHz
UMTS
Top view793 425, 782 10245 Single Unit 793 426, 782 10246 Double Unit
Side view793 425, 782 10245 Single Unit
Side view793 426, 782 10246 Double Unit
Page 2 of 2 793 425, 793 426, 782 10245, 782 10246 KATHREIN-Werke KG . Anton-Kathrein-Strae 1 3 . PO Box 10 04 44 . D-83004 Rosenheim . Germany . Telephone +49 8031 1 84-0 . Fax +49 8031 1 84-9 91
Internet: http://www.kathrein.de
Accessories (order separately)
734 360 34 60 mm734 361 60 80 mm734 362 80 100 mm734 363 100 120 mm734 364 120 140 mm734 365 45 125 mm
Clamp setType No. suitable for mast
diameter of
Type No. Description
793 301 DC stop
IP66 protection will be lost, and all corresponding guarantees will become null and void, if mounting brackets areremoved or tampered with. Upgrading from existing single units to double units is possible, but can only be car-ried out at Kathrein due to IP66 considerations.As a result of more stringent legal regulations and judgements regarding product liability, we are obliged to point out certain risks that may arise when products are used under extraordinary operatingconditions.Extraordinary operating conditions, such as heavy icing or exceptional dynamic stress (e.g. strain caused byoscillating support structures), may result in the breakage of a mast mounted device or even cause it to fall tothe ground.These facts must be considered during the site planning process.The Triple-band Combiners are designed to operate under the environmental conditions as described in ETS 300 019-1-4 class 4.1 E and have passed environmental tests as recommended in ETS 300 019-2-4.The installation team must be properly qualified and also be familiar with the relevant national safetyregulations.
The details given in our data sheets have to be followed carefully when installing the antennas, filters, combiners, amplifiers and accessories.
The limits for the coupling torque of RF connectors, recommended by the connector manufacturersmust be obeyed.Any previous datasheet issues have now become invalid.
Please note:
Clamp Set