Download - Thermoplastic Preheaters (US units) · Thermoplastic Preheaters (US units) Borum International A/S Højvangsvej 10 Hadbjerg DK-8370 Hadsten Phone +45 8761 3213 Fax +45 8761 3214 [email protected]

Transcript
Page 1: Thermoplastic Preheaters (US units) · Thermoplastic Preheaters (US units) Borum International A/S Højvangsvej 10 Hadbjerg DK-8370 Hadsten Phone +45 8761 3213 Fax +45 8761 3214 info@borum.as

Thermoplastic Preheaters (US units)Thermoplastic Preheaters (US units)Thermoplastic Preheaters (US units)Thermoplastic Preheaters (US units)

Borum International A/SHøjvangsvej 10

HadbjergDK-8370 Hadsten

Phone +45 8761 3213Fax +45 8761 3214

[email protected]

- it's straightforward

BORUM thermoplasticBORUM thermoplasticBORUM thermoplasticBORUM thermoplasticpreheaterspreheaterspreheaterspreheatersfor trouble-free heating of block,granulate or liquid thermoplasticmaterial.Efficient vertical double mixer arms,which ensure uniform heating of thematerial. 2 inch heat insulation.Hydraulic forward/reversetransmission. Preheaters driven by ahydraulic power unit, which can beinstalled independent of location ofpreheater. Standard length forconnection of hoses and cables 20feet. Diesel oil burner or propane gassystem can be supplied for heating.All sizes of preheaters up to 1600 canbe delivered as double (twin) unitsdriven by a common BM PS-15 powerunit.

ID Indirectly heated preheater.ID Indirectly heated preheater.ID Indirectly heated preheater.ID Indirectly heated preheater.Hydraulic motor with agitator bearing.Start/stop/reverse valve for agitatordrive. Vertical agitator with doublearms and paddles.Material container surrounded by heattransfer oil, to distribute heat.Oil-heated center pipe in materialtank. Oil-heated material outlet.The preheater is equipped with athermostat for thermoplastic materialand for heat transfer oil temperaturesfrom 122°F to +518°F. Includes anintegrated display showing actualtemperatures.

Standard sizes 66 US Gal., 106 USGal., 159 US Gal, 211 US Gal., 291US Gal., 423 US Gal, 660 US Gal.

D Directly heated preheatersD Directly heated preheatersD Directly heated preheatersD Directly heated preheatersHydraulic motor with agitator bearing.Start/stop/reverse valve for agitatordrive. Agitator with double arms andpaddles.The preheater is equipped with athermostat for thermoplastic materialtemperatures from 122°F to 518°F.Includes an integrated displayshowing actual thermoplastictemperature.

Standard sizes 79 US Gal., 132 USGal., 198 US Gal., 264 US Gal.

Hydraulic Power Unit:Hydraulic Power Unit:Hydraulic Power Unit:Hydraulic Power Unit:

BM PS-15 Hydraulic power unitBM PS-15 Hydraulic power unitBM PS-15 Hydraulic power unitBM PS-15 Hydraulic power unitSuitable for powering one or twopreheaters.9.5 kW (13 HP) at 3600 rpm. Water-cooled 2-cylinder diesel engine.22 US Gal. diesel oil tank with levelcontrol and diesel oil filter.2x0,27 Cubic Inch/rev. hydraulicpump with safety valve, capacity2x2,9 US Gal./min v. 2400 rpm.17,5 Gal Hydraulic oil tank with filter.Alternator 12 V DC/65 Amp. Enginefoundation with vibration absorbers.Noise level @ 23 feet distance ≈ 73dbA

BM PS-9 Hydraulic Power UnitBM PS-9 Hydraulic Power UnitBM PS-9 Hydraulic Power UnitBM PS-9 Hydraulic Power UnitSuitable for powering one preheateronly.7.0 kW (9HP) at 3600 rpm. Aircooled1-cylinder diesel engine. 22 US Gal.diesel oil tank with level control anddiesel oil filter.0,27 Cubic Inch/rpm hydraulic pumpwith safety valve. Capacity 2,9 USGal./min v. 2400 rpm.17,5 US Gal. hydraulic oil tank withfilter. Alternator 12 V DC/55 Amp. Enginefoundation with vibration absorbers.Noise level @ 23 feet distance ≈ 68dbA

Diesel oil burnerDiesel oil burnerDiesel oil burnerDiesel oil burnerDiesel oil burner for 12 V DC powersupply.

Propane burnerPropane burnerPropane burnerPropane burnerPropane burner with electric ignitionand safety system. Active flamecontrol.

Available on demand

Dimensions and weight

Filling system:Filling system:Filling system:Filling system:

Filling system for transportation andlift of thermoplastic, mostly used fortransporting thermoplastic frompreheaters placed on a supply truck/trailer to a material tank placed onthe marking truck.

Borum has the following fillingsystems:

TLS 1TLS 1TLS 1TLS 1- for connecting to a singlepreheater.

TLS 2TLS 2TLS 2TLS 2- for connection to doublepreheaters.The units have a hydraulically drivenpiston pump. The bottom part and material pipe isheated by heat transmission oil,which is circulated by a hydraulicallydriven pump.When run by a standard PS 15, thecapacity is 11 US Gal./min.Capacity for both models can be upto 32 US Gal./min, when fed by 8US Gal./min hydraulic oil. Forinstance if operated by a PS 15 withextra large hydraulic pump

Auger pumpAuger pumpAuger pumpAuger pumpis mounted on single preheater. Thepump is driven by a hydraulic motor.The pump and pivoted material pipeis heated by heat transmission oil,which is circulated by a hydraulicallydriven pump.The capacity is 12 US Gal./min,when operated by a PS 15, providedwith extra large hydraulic pump.

Gear pump SP 2000Gear pump SP 2000Gear pump SP 2000Gear pump SP 2000 is especially used for jobs with biglifting height, or long material pipe.The gear pump is operated by ahydraulic motor.Pump and material pipes are heatedby heat transmission oil, which iscirculated by a hydraulically drivenpump.Max capacity is 32 US Gal./minwhen fed with 8 US Gal./min.hydraulic oil flow. For the SP2000 a motor driven PTOcan be used for driving a hydraulicpump. An electrically operatedcontrol valve govern the gear pumpspeed.With this arrangement remoteoperation of the pump system caneasily be performed.

See photos of Borum filling systems

Modification rights reserved.