The use of free-space microwave non-destructive techniques: simulation of
damage detection in carbon fibre reinforced composites.
Daniela Munalli1∗, Georgios Dimitrakis2, Dimitrios Chronopoulos1,Steve Greedy3, and Andrew Long1
1The Composites Research Group, The University of Nottingham, Nottingham, UK2Department of Chemical and Environmental Engineering, The University of Nottingham, Nottingham, UK
3School of Electrical and Electronic Engineering, The University of Nottingham, Nottingham, UK
*corresponding author, E-mail: [email protected]
AbstractMicrowave non-destructive testing (MNDT) methods rep-
resent an effective solution in detecting defects within com-
posite structures with relatively low electrical conductivity.
They offer the advantage to overcome the problems of tra-
ditional NDT techniques such as coupling, danger coming
from ionizing radiation, limited depth of operation, large
wavelengths, time consuming post processing. Near-field
microwave and millimetre non-invasive inspections have
been successfully used for detecting defects such as dis-
bond and delamination in complex structures. In dielectric
materials, they can be used for dielectric properties char-
acterization, degree of porosity evaluation, degree of age-
ing, anisotropy, dielectric mixture constituents determina-
tion, state of cure. When it comes to the analysis of car-
bon fibre reinforced polymers (CFRPs), the use of these
non-destructive techniques is restricted by the composite
relatively high conductivity of about 104 S/m. In this pa-
per, the investigation of a free-space microwave method for
non-destructive testing of unidirectional CFRPs has been
carried out by means of a pair of standard gain horn anten-
nas, covering a frequency range from 26.5 GHz to 40 GHz.
With the simulations, experimental results related to the
presence/severity of the analysed defects are linked to the
variations of the measured scattering parameters Sij . The
approach is based on the comparison between the electro-
magnetic signal reflected and transmitted through a healthy
sheet material under test, when a radio frequency (RF) wave
is incident on it, and the one reflected and transmitted by a
damaged sheet. The eventual presence of the defect is re-
vealed by measuring the mismatch between the two trans-
mitted waveforms. The performance of this radio wave
technique is investigated in relation to surface defects and
also in relation to those types of defects that are less de-
tectable with this method, such as delaminations, cavities
and inclusions. The simulations make use of the finite
integration technique (FIT) and the finite element method
(FEM).
1. Introduction
Carbon fibre-reinforced polymer (CFRP) composites are
extensively being used in the aerospace industry due to their
outstanding mechanical properties, such as light weight,
fatigue tolerance, corrosion resistance and high specific
strength and modulus [1, 2]. Structural components of air-
planes and helicopters such as frames, rotor blades, cowl-
ing, control surfaces, wing skin, leading edge and trailing
edge panels are made of CFRPs [3]. Because of their phys-
ical characteristics, the application of carbon fibre compos-
ites to modern aircraft has progressed even more in recent
years; about 40% of the structural weight of the Eurofighter
is carbon-fibre reinforced composite material [4], 50% of
the weight of the Boeing 787 Dreamliner consists of com-
posite materials, resulting in an airframe comprising nearly
half carbon fibre reinforced plastic and other composites
[5].
Unlike metals, composite materials present non-
homogeneity and anisotropy or eventually orthotropic be-
haviour [6]. The damage propagation is diffused and pro-
gressive instead of being confined to a single macrofrac-
ture and involves different modes of failures such as fibre
breakages, matrix transverse cracking and delamination [7].
In addition, manufacturing defects can be embedded in the
structure and may grow during the in service life. Com-
monly induced flaws, which can originate from lack in the
manufacture process control, include porosity, presence of
foreign bodies, fibre or ply misalignment, incorrect fibre
volume fraction, bonding defects [8]. In many occasions,
the damage evolves internally and is hardly visible. Hence,
because of the complexity of damage prediction in com-
posites, it is important to assess their structural integrity
through accurate routine checks.
The inspection methods used to verify the quality state
of a structure without causing any damage or significant
change in the structure itself are defined as Non Destructive
Testing (NDT) techniques. NDT methodologies range from
simple visual inspection and the so-called coin tapping to
very sophisticated techniques; the most suitable for com-
posites are ultrasonic inspections, acoustic emission, ther-
mography, radiography and optical techniques (shearogra-
phy) [9]. However, no single method exists that can detect
all types of manufacturing defects and in-service damage,
and a combination of more techniques can be required for a
detailed inspection of a structural component [10].
More
info
about
this
art
icle
: htt
p:/
/ww
w.n
dt.
net
/?id
=25070
Copyright 2019 - by the Authors. License to Cofrend and NDT.net.
An alternative method of damage inspection and char-
acterization of composite materials consists in the use of
microwave and millimeter wave techniques. Electromag-
netic waves are sent from a transmitting antenna to the sam-
ple under test (SUT) in microwave and millimeter wave
regime (300 MHz to 300 GHz); the portion of the signal
reflected and/or transmitted through the SUT to a receiver
antenna is analyzed in order to evaluate hidden or embed-
ded objects [11]. These methods are indicated to overcome
the limitations of conventional NDT; they work easily in
reflection and transmission configurations, they do not re-
quire a coupling agent, the microwave testing systems are
safe to use due to their low power needs, the probe can be
located at a distance from the analyzed structure making
possible high temperature inspections and testing on mov-
ing objects, it is possible to achieve real time applications
and repetitiveness of measurements [12].
As a matter of fact, microwave non-destructive testing
(MNDT) techniques have been so far extensively applied
to dielectric materials, due to the ability of microwaves to
pass through non-conducting media [13]. In near-field ap-
plication, Qaddoumi et al. detected aluminium inclusion
and flat bottom holes in fibreglass composites [14, 15],
rust under composite laminate coatings [16], and charac-
terized electric properties (dielectric permittivity, dielectric
loss) of cured and uncured resin binder for fibreglass rein-
forced composites (GFRP) [17] by using open-ended rect-
angular waveguides. Similarly, near-field microwave imag-
ing was employed to detect defects in sandwich compos-
ites, such as skin/core debonding, core cracking and impact
damage [18, 19]. In far-field application, Yu et al. used
a measurement system made of a horn antenna and reflec-
tors to identify debonding in artificially damaged GFRP-
concrete cylinders [20, 21, 22]. A free-space measurement
system, composed of two horn antennas in transmitting
and receiving configurations, was successfully used to de-
termine complex permittivity and complex permeability in
several microwave-absorbing materials [23, 24] and fibre-
glass composites [25].
In recent years, MNDT methods are being considered
for application towards CFRPs. A detailed survey about
this topic was proposed by Li et al [26]. However, the use
of microwave techniques is constrained by the high elec-
trical conductivity of the carbon fibres, which ranges from
3.84×104 S/m to 105 S/m in accordance with the typology
of graphitisation treatment [27]. In this case, the high con-
ductivity of the carbon fibres shields the electromagnetic
radiation, making the material scarcely penetrable by elec-
tromagnetic waves. Therefore, the use of MNDT is con-
sidered limited to surface defects (impact damage, surface
irregularity, indentation), and to defects contained in the
first layers of the laminate, due to the severe skin effect
of carbon fibre polymers [28]. As evidence, in literature
MNDT techniques have been proved valid for the detec-
tion of fibre breakage and fibre orientation in unidirectional
(UD) CFRPs [29], disbonds between CFRP patches and
concrete structures [30, 31], detection of impact damage
[32, 33], surface and sub-surface defects identification on
CFRP sheets [34, 35]. Furthermore, most commonly used
sensors for this typology of damage detection operate in
near-field applications and consist of open-ended rectangu-
lar waveguides [29, 30], horn antennas in reflection config-
uration [32, 36], microwave resonators [33, 35].
In this paper, the use of a free-space MNDT technique
for damage detection in unidirectional CFRPs is investi-
gated. Experimental simulation data of the near-field mi-
crowave technique are presented in the Ka band, where
the homogenized properties of the material were obtained
through comparisons with a meso-scale FEM modeling of
the laminate under study. In this way, a simplified electro-
magnetic model of a carbon fibre composite can be rep-
resented through electromagnetic analysis software, such
as CST (Computer Simulation Technology) MWS (mi-
crowave studio), saving computational costs. Once applied
to the SUT, the free-space MNDT method was proved use-
ful for detecting defects, such as delaminations, foreign
bodies and surface indentation.
2. Electromagnetic characteristics of CFRP
materials
Materials can be classified according to their permittivity
ε(ω), that is a complex number, through the ratio between
its imaginary part and real part. Having defined the relative
permittivity of a material as:
εr =ε
ε0= ε′r − j(ε′′r +
σ
ε0ω) (1)
where ε0 is the permittivity of free space (i.e.
8.8542×10−12 F/m), the real part of εr (dielectric
constant) is related to the efficiency of the material to
store the electrical energy, while the imaginary part of εris linked to the energy losses, in particular to the Joule
effect losses through the electrical conductivity σ and to
the losses related to the orientation of the dipoles in the
medium through ε′′r . The ratio between the imaginary
part and the real part of εr, or Dissipation Factor (DF), is
used to classify materials as: perfect dielectric materials or
lossless mediums (DF = 0), low loss mediums with good
dielectric properties or poor conductors (DF ≪ 1), good
conductors or high loss mediums (DF ≫ 1) and perfect
conductors (DF = ∞) [37, 38].
Composite materials for their definition are made of
different elements with corresponding different electrical
properties. The composites under analysis are made of
epoxy resin, which is a common electric insulator with
dielectric constant of about 3÷6 [39], and continuous
carbon fibres based on Polyacrylonitrile (PAN) precursor.
The PAN based carbon fibres have about 60000-70000 S/m
of electrical conductivity [40] and their magnetic perme-
ability µ is equal to that of the free space µ0 = 4π × 10−7
H/m. Therefore, the conductivity of the whole composite
is highly dependent upon its structure and the arrangement
of the fibres inside the matrix. If the fibres were to be
perfectly straight and did not contact adjacent fibres in the
2
two transverse directions, even composites filled with high
conductive reinforcements would be highly insulating. In
reality, fibres are in contact also in the transverse directions.
Hence, it is reported in literature that the mean conductivity
σ of CFRPs is of about 104 S/m [41] and the electrical
conductivity in the direction transversal to fibres is of four
orders lower than the in plane conductivity [40]. Finally,
it is seen that the conductivity of the whole composite is
dependent upon its percolation threshold [42], and that
in function of this parameter CFRPs behave like a lossy
medium [43], or a medium-high lossy medium [44].
Consequently, to achieve optimum signal penetration
at Ka band, where the high frequency reduces the value of
the skin depth of the material, unidirectional CFRPs were
considered for this study instead of textile composites. UD
composites exhibit medium transparency to radiation when
the electric field is transverse to the fibres direction (i.e. the
number of contact points among fibres decreases), while,
if the polarization of the field is parallel to the direction of
the fibres, the transmission through the material is highly
attenuated [12]. Transverse polarization can therefore be
significant for damage identification in UD composites.
3. Transmission coefficients of textile dry
fibres
In this section, CST Studio Suite was adopted to perform
calculations of the reflection coefficient S11 and transmis-
sion coefficient S21 for dry carbon fibres in the frequency
range from 30 MHz to 1.5 GHz. The simulation software
was applied to numerically analyze the interaction of the
SUT with a far-field electromagnetic radiation in the men-
tioned frequency band; from S-parameters (Sij) calcula-
tions, it was possible to assess the shielding effectiveness
(SE) value for the material, i.e. the ability of a barrier to
block the field radiation. Subsequently, experimental mea-
Figure 1: 2/2 twill woven fabric made of TR30S 3k.
surements were carried out for validation.The material un-
der analysis is a layer of dry PAN based carbon fibres fabric
(Pyrofil TR30S), intertwined according to a 2/2 twill weave
pattern as shown in Fig. 1. The relevant properties of the
carbon fabric are listed in Table 1.
Table 1: Pyrofil TR30S properties .
Type Number of Filament Diameter Yeld
Filaments [µm] [mg/m]
TR30S 3k 3000 7 200
3.1. Simulation analysis
The first step of the simulation work was to model the ge-
ometry of a single unit cell (UC) of the carbon textile at
a mesoscale level, using a specialist pre-processor such as
Texgen [45]. The in-plane dimensions of the unit cell were
obtained from direct measurements of the twill weave. The
length of a unit cell is approximately 7.8 mm, while the yarn
width is ≃ 1.6 mm as illustrated in Fig. 2. The thickness of
Figure 2: Unit cell of 2/2 twill weave pattern.
the woven fabric was measured with an electronic microm-
eter with 0.001 mm resolution and is ≃ 0.23 ± 0.023 mm.
The TexGen geometry base model (dimensions are defined
in Fig. 3) was imported in CST Studio Suite, whose fre-
quency solver is based on FEM (Finite Element Method).
The unit cell boundary condition was adopted, in order to
obtain a periodic structure in the x-y plane, as shown in Fig.
3. The excitation used was an incident plane wave polarized
Figure 3: Simulation methodology for the mesoscale fabric
layer.
according to y direction. For a carbon fibre material with
60000 S/m of conductivity, a refined mesh of 962379 tetra-
hedron elements (minimum edge length ≃ 2.9e-005 mm)
and 24 GB of RAM were required; the simulation time was
3
of 1h 37m 12s, with a Intel Xeon W-2123 CPU. A reflection
coefficient of S11 = -0.019 dB and a transmission coefficient
of S21 = -55.9 dB were obtained. These values indicate a
very high level of shielding effectiveness for just a single
layer of dry fibres, corresponding to a degree of signal at-
tenuation > 99%. It is worth to notice that this particular
structure has also the same geometric configuration along
x-axis , thus, an eventual polarization of the electromag-
netic field along this direction would give the same results
in terms of scattering parameters. The results indicate that a
non-isotropic geometry would rather allow greater penetra-
tion to electromagnetic waves, this is the case for UD fabric.
In Fig. 4, it can be noticed how conveniently changing the
value of the reference parameters can increase or decrease
the SE of the fabric. In particular, increased thickness of
the fabric layer, increased yarn width and decreased space
between yarns favor a greater electromagnetic attenuation.
Figure 4: Effect of fabric thickness, yarn width and UC
length on simulated microwave transmission coefficient.
3.2. Experimental validation
The results obtained in section 3.1 were validated through
Figure 5: Sample of TR30S fabric shaped according to
ASTM D4935 standard: (a) Reference specimen; (b) Load
specimen.
the experimental measurements presented in [46, 47]. One
of the most common methods used to measure the transmis-
sion coefficient of a planar material under normal incidence
of a plane wave, involves the transition of a guided TEM
wave in a coaxial transmission fixture containing the SUT,
in accordance with ASTM D4935 standard. The specimens
need to be shaped to fit the inner conductor and the outer
conductor, as shown in Fig. 5 and Fig. 6. Knowing the in-
Figure 6: ASTM D4935 test method for measurement of
shielding effectiveness (SE). On the left brass coaxial unit
holder. On the right SUT positioning.
put power Pi, the transmission coefficient (SEff21
) was cal-
culated measuring the power transmitted through the Refer-
ence SUT (PReft ) first, and then measuring the power trans-
mitted through the Load SUT (PLoadt ), according to equa-
tion 2:
∣
∣
∣SEff21
∣
∣
∣
dB=
∣
∣SLoad21
∣
∣
dB−∣
∣
∣SRef21
∣
∣
∣
dB= 10 log
10
PLoadt
PReft
(2)
where:∣
∣SLoad21
∣
∣
dB= 10 log
10
PLoadt
Pi
(3)
∣
∣
∣SRef21
∣
∣
∣
dB= 10 log
10
PReft
Pi
(4)
Fig. 7 displays the transmission coefficient measured
for 1 layer of carbon fabric and the results of the simulation
(Base model), allowing for comparison.
Figure 7: Measured and simulated transmission coefficient
S21 of TR30S fabric over 0.03-1.5 GHz.
The average value of the transmission coefficient |S21| reg-
istered by the Vector Network Analyzer (VNA) is 54.5 dB,
4
Figure 8: Unit cell base model for a UD laminate with 8 layers: (a) particular of the single yarn with dimensions; (b) detailed
unit cell model, where the green color indicates the epoxy matrix; (c) periodic expansion of the unit cell, the UD fibres are
oriented along x-axis.
against 55.9 dB of the simulation. In average, the simula-
tion results are higher in SE compared to the experimental
ones, however, the numerical model corresponds to a great
extent to the measured data. Therefore, CST simulations
can be used to describe the shielding behaviour of carbon fi-
bre yarns at a mesoscale level. In the following section, this
aspect will be applied to the case of unidirectional yarns, in
order to model a unit cell of a unidirectional CFRP lami-
nate.
4. Ka-band electromagnetic simulation of
unidirectional carbon fibre composites
A unidirectional CFRP laminate composed of 8 layers
is modelled with CST FEM solver, using the procedure
Figure 9: (a) Unidirectional dry carbon fibres with warp
made of Pyrofil TR50S 15k; (b) CFRP laminate made of
8 layers of TR50S non-woven carbon fibre and XPREG
XA120 epoxy adhesive film, oriented along 0direction.
described in section 3.1. The geometry of a single layer
was implemented with Texgen, where both fibre yarn and
epoxy matrix were defined. Then, the lamina sheet (fibre
yarn and epoxy resin) was imported in CST and replicated
8 times, in order to obtain the specific unit cell as basic
structure of the periodic expansion (Fig. 8). The geometric
dimensions were chosen according to the sample shown
in Fig. 9. The thickness of the yarn corresponds to the
thickness of a UD layer of TR50S [Fig 9 (a)], and is equal
to ≃ 0.121 ± 0.007 mm. The thickness of the whole
composite reproduces the thickness of the cured laminate,
composed of 8 layers of non-woven carbon fibre cloth in
epoxy resin staked along 0direction [Fig 9 (b)], and is
equal to ≃ 1.744 ± 0.03 mm. From an electromagnetic
point of view, it was assumed not to take into account the
yarn fibre volume fraction and that very limited amount
of resin is present between adjacent yarns along y-axis to
compensate for the lack of contact points. Two adjacent
yarns can be viewed as the two parallel conductive plates of
capacitor, decreasing the distance between the two results
in an increase of displacement current in the y direction.
Hence, the yarns are modeled with a conductivity of
60000 S/m, while a dielectric constant equal to 4 and a
conductivity of 1e-011 S/m are assigned to the epoxy resin,
knowing that a typical unfilled epoxy resin has a volume
resistivity of > 108 Ωm [48]. The aim of this study was to
perform a microwave analysis of the composite laminate
taking into consideration the separate electromagnetic
modelling of fibres and matrix at a mesoscale level, and
subsequently produce an effective homogeneous equivalent
model to use for damage investigation, as illustrated in
Fig. 10. A homogeneous material is needed for damage
simulation, because commonly used electromagnetic
solvers for structures at high frequencies, such as CST and
Ansys HFSS, are computationally demanding and would
require a very large number of mesh elements to reproduce
a layered composite structure with high conductive parts.
Consequently, the goal was to obtain the anisotropic
5
electrical conductivity of the equivalent model along the
three axes, typical of a unidirectional laminate. Two
different polarization modes were chosen, Mode 1 with
polarization aligned with y-axis, in direction perpendicular
to the fibres, and Mode 2 with polarization aligned with
x-axis, in direction parallel to the fibres, in order to assess
the transmission coefficients in both directions.
Figure 10: (a) detailed unit cell model; (b) equivalent ho-
mogenized unit cell model with σ=[1000,22,0.15] S/m.
The simulated values of |S21| for the detailed unit cell
model [Fig. 10 (a)] are in average 23.9 dB along y-axis and
165 dB along x-axis, over the selected frequency range [27-
32 GHz] in the Ka band. These results were obtained with
a mesh of 35313 tetrahedrons, and a calculation time of 2m
46s occupying 2.6 GB of RAM.
As expected, the electromagnetic wave attenuation in
the direction of the conductive fibres is very high, since any
attenuation higher than 100 dB implies that the material
is essentially impenetrable. Instead, |S21| is considerably
lower in the y direction (fewer contact points between fi-
bres), allowing penetration of electromagnetic waves. This
observation is of interest for damage inspection and the ho-
mogenized equivalent model must comply with this condi-
tion.
It was found that an anisotropic material with electrical
conductivity σ=[1000,22,0.15] S/m, Fig. 10 (b), exhibits an
attenuation of 23.9 dB along the y direction and 164.2 dB
along the x direction (average values over a frequency range
of 27-32 GHz). The model is composed of 53768 mesh el-
ements and has a calculation time of 2m 59s occupying 0.7
GB of RAM.
Fig. 11 shows the two models compared for polariza-
tion 1 and 2. The average difference in |S21| between the
two models is ∆S21(1) ≃ 0.62 dB for Mode 1 simulation,
while for Mode 2 is ∆S21(2) ≃ 2.77 dB. The equivalent
model can therefore be used in this frequency range as sub-
stitute for the detailed model for preliminary damage in-
spection analysis.
5. Damage simulation analysis using Finite
Integration Technique (FIT)
5.1. Modelling
Using the electrical conductivities of the above equiva-
lent model, a computer simulation was performed to ex-
Figure 11: S21 parameter calculated for detailed model and
equivalent model for Mode 1 and Mode 2, over 27-32 GHz.
amine whether the free-space method is appropriate for
defects’ detection. The transient solver based on the Fi-
nite Integration Technique (FIT) was used, where the FIT
method is a spatial discretization scheme to numerically
solve Maxwell’s equations in their integral form in time and
frequency domain [49].
The chosen free-space method consists of two horn
Figure 12: Free-space model used to characterize the trans-
mission scattering parameter S21, over 28-32 GHz.
antennas in transmitting and receiving configuration in the
near-field. The system shown in Fig 12 was used as base-
model for the simulations, considering normal incidence,
y-axis polarization of the field and a Gaussian-modulated
sinusoidal RF pulse [V(t)] assigned to port 1. The reflec-
tion/transmission responses are obtained from power waves
[50], in a frequency band ranging from 28 GHz to 32 GHz.
The specimen (square shaped) was placed between the two
horn antennas, whose specifications are listed in Table 2.
6
To avoid numerical dispersion, the shortest wavelength of
Table 2: LB-28-20-C horn technical specification
Frequency range [GHz] 26.5-40.0
Waveguide WR28
Gain [dB] 20 Typ
Polarization Linear
Material Cu
Size [mm] 32.1 × 40.4 × 94.0
interest was spatially sampled at a rate of 10 mesh cells
per wavelength, taking into account that the phase velocity
of the electromagnetic radiation varies in the medium and
consequently the wavelength becomes drastically shorter in
a conductive medium (λm) than in the air (λ0). In a con-
ductive medium, with σ ≫ ωε′ and DF ≫ 1, λm can be
written as:
λm ≃ 2√π√
fµσ(5)
where µ is the permeability.
5.2. Damage detection
Several damage configurations were considered for the
aforementioned specimen with σ=[1000,22,0.15] S/m. The
aim is to know whether variations of the scattered signal
can be detected due to the presence of a near-surface de-
fect. Fig. 13 shows the case of a square element of 15 mm
Figure 13: Free-space MNDT model used to characterize
S21 for inter-laminar damage and inclusions.
× 15 mm × 0.23 mm inserted in the middle section (x-y
plane) of the specimen. This element was used to simulate:
(a) delamination with PTFE patch, (b) air delamination, (c)
square inclusion with σ=104 S/m, as described in Table 3.
The transmission coefficient for the three cases is compared
with the one of the undamaged base model in Fig. 14.
In case of inter-laminar defect, an artificial delamina-
tion of 0.23 mm in thickness was created filling the inset of
Fig. 13 with PTFE (Teflon) or air. The scattering curves
for the two delamination models, shown in Fig. 14, exhibit
Table 3: Inner defects considered for simulation.
Type of defect Execution EM Properties
Delamination Teflon patch ε′r=2.1
Delamination Air ε′r=1.00059
Inclusion/Clumped fibres Lossy medium σ=104 S/m
greater power transmission through the specimen with re-
spect to the undamaged model, and slightly overlap each
other. This behaviour is the result of the interruption of
the flow of electric current along the thickness, due to the
discontinuity generated by the delamination. On the other
Figure 14: Comparison of the simulated transmission coef-
ficient S21 of damaged models with undamaged case, over
28-32 GHz.
hand, when the element of Fig. 13 is used to simulate an
inclusion with higher conductivity that the host material,
the SE increases, the electromagnetic wave is further re-
flected back at the interface between the inset and surround-
ing composite (greater return loss) and at the same time also
the absorption loss increases.
The experimental data for the delamination models
were obtained with a mesh of 21895335 hexahedral ele-
ments for a simulation that lasted ≃ 50 min and 2.6 GB
of RAM needed. Instead, the analysis of the conduc-
tive inclusion required 168269500 hexahedral elements (the
wavelength inside the conductive material decreases signif-
icantly and consequently the number of cells increases, be-
ing their dimension equal to 1/10 of λm), and had a duration
of ≃ 7 h using 19.8 GB of RAM. For the models, opportune
condition of symmetry were chosen to reduce the calcula-
tion domain, it was assumed ~Ht=0 on yz plane and ~Et=0
on xz plane.
In both the examples produced, delamination and inclu-
sion, it was possible to clearly assess the presence of the
damage, through changes in the magnitude of S21 with re-
spect to the undamaged model. The same can be said in
case of detection of surface defects, such as indentations
(Fig. 15). A square indentation of 4.7 mm × 4.7 mm ×0.3 mm can be easily identified, as illustrated in the graphic
of Fig. 16. The first boundary encountered by the radia-
tion changes compared to the undamaged model, affecting
7
Figure 15: Free-space MNDT model used to characterize
S21 for surface damage.
the reflection loss and resulting in a lower SE. A surface
defect is expected to be identified with the MNDT meth-
ods and the experimental data confirm the results produced
in literature. The analysis required 21895335 hexahedral
elements, a duration of ≃ 50 min and 2.6 GB of RAM.
Figure 16: Transmission coefficient S21 for specimen with
indentation and without indentation, over frequency span of
28-32 GHz.
6. Conclusions
In this study, CST was successfully used to simulate the
electromagnetic behaviour of a carbon woven textile. Con-
sidering the promising result, it is suggested that the simu-
lation tool could be employed to study the applicability of
near-field MNDTs to damage detection in carbon compos-
ite laminates before practical application.
For this purpose, a free-space microwave method, con-
sisting of two horn antennas in transmission and reception,
was considered to numerically analyze defects in UD lami-
nates with a suitable polarization perpendicular to the fibres
direction. The simulation results indicate that inter-laminar
damage, such as delamination, can be easily detected in
transmission configuration and the same can be said for sur-
face defects and foreign bodies.
The MNDT analysis was possible due to an opportune
simplified electromagnetic model of a unidirectional carbon
fibre composite, allowing for modelling of composites with
electromagnetic high frequencies analysis tools.
In further work, the optimum selection of the angle of
the incident radiation is to be explored, which could be ben-
eficial to extend the application of the free-space method
from the case of unidirectional laminate to the case of car-
bon textile composites.
Acknowledgement
This work was funded by the INNOVATIVE doctoral
programme. The INNOVATIVE programme is partially
funded by the Marie Curie Initial Training Networks (ITN)
action (project number 665468) and partially by the Insti-
tute for Aerospace Technology (IAT) at the University of
Nottingham.
The work was supported through the provision of a coop-
eration license for the CST Studio Suite by CST (Dassault
Systemes).
References
[1] C. Soutis, “Fibre reinforced composites in aircraft
construction,” Progress in aerospace sciences, vol. 41,
no. 2, pp. 143–151, 2005.
[2] S. Chand, “Review carbon fibers for composites,”
Journal of materials science, vol. 35, no. 6, pp. 1303–
1313, 2000.
[3] P. Mangalgiri, “Composite materials for aerospace
applications,” Bulletin of Materials Science, vol. 22,
no. 3, pp. 657–664, 1999.
[4] A. Quilter, “Composites in aerospace applications,”
IHS White Paper, vol. 444, no. 1, 2001.
[5] J. Hale, “Boeing 787 from the ground up,” Aero,
vol. 4, no. 24, p. 7, 2006.
[6] R. M. Jones, Mechanics of composite materials.
CRC press, 2014.
[7] R. F. Landel and L. E. Nielsen, Mechanical properties
of polymers and composites. CRC press, 1993.
[8] R. Smith, “Composite defects and their detection,”
Materials science and engineering, vol. 3, pp. 103–
143, 2009.
[9] J. Summerscales, Non-destructive testing of fibre-
reinforced plastics composites. Springer Science &
Business Media, 1990, vol. 2.
[10] C. Boller, F.-K. Chang, and Y. Fujino, Encyclopedia
of structural health monitoring. Wiley, 2009.
8
[11] J. Blitz, Electrical and magnetic methods of non-
destructive testing. Springer Science & Business
Media, 2012, vol. 3.
[12] S. Kharkovsky and R. Zoughi, “Microwave and mil-
limeter wave nondestructive testing and evaluation-
overview and recent advances,” IEEE Instrumentation
& Measurement Magazine, vol. 10, no. 2, pp. 26–38,
2007.
[13] R. Zoughi, Microwave non-destructive testing and
evaluation principles. Springer Science & Business
Media, 2000, vol. 4.
[14] N. N. Qaddoumi, G. W. Carriveau, S. I. Ganchev, and
R. Zoughi, “Microwave imaging of thick composite
panels with defects,” 1995.
[15] N. Qaddoumi, H. Abiri, S. Ganchev, and R. Zoughi,
Near-field analysis of rectangular waveguide probes
used for imaging. Springer, 1996, pp. 727–732.
[16] N. Qaddoumi and R. Zoughi, “Microwave detection
of corrosion under paint and composite laminate coat-
ings,” in Nondestructive Evaluation of Aging Aircraft,
Airports, and Aerospace Hardware, vol. 2945. Inter-
national Society for Optics and Photonics, Conference
Proceedings, pp. 346–352.
[17] N. Qaddoumi, S. Ganchev, and R. Zoughi, “Mi-
crowave diagnosis of low-density fiberglass compos-
ites with resin binder,” Research in Nondestructive
Evaluation, vol. 8, no. 3, pp. 177–188, 1996.
[18] S. I. Ganchev, R. J. Runser, N. Qaddoumi, E. Ranu,
and G. Carriveau, “Microwave nondestructive evalua-
tion of thick sandwich composites,” Materials evalu-
ation, vol. 53, no. 4, 1995.
[19] G. Green, P. Campbell, and R. Zoughi, “An investi-
gation into the potential of microwave nde for mar-
itime application,” in 16th World Conference of Non-
Destructive Testing, vol. 30, Conference Proceedings.
[20] T.-Y. Yu and O. Buyukozturk, “A far-field air-
borne radar ndt technique for detecting debonding in
gfrp–retrofitted concrete structures,” NDT & E Inter-
national, vol. 41, no. 1, pp. 10–24, 2008.
[21] O. Buyukozturk and T.-Y. Yu, “Far-field radar ndt
technique for detecting gfrp debonding from con-
crete,” Construction and Building Materials, vol. 23,
no. 4, pp. 1678–1689, 2009.
[22] T.-Y. Yu and O. Buyukozturk, “A distant real-time
radar nde technique for the in-depth inspection of
glass fiber reinforced polymer-retrofitted concrete
columns,” in Nondestructive Characterization for
Composite Materials, Aerospace Engineering, Civil
Infrastructure, and Homeland Security 2008, vol.
6934. International Society for Optics and Photonics,
Conference Proceedings, p. 69340W.
[23] D. Ghodgaonkar, V. Varadan, and V. Varadan, “Free-
space measurement of complex permittivity and com-
plex permeability of magnetic materials at microwave
frequencies,” IEEE Transactions on instrumentation
and measurement, vol. 39, no. 2, pp. 387–394, 1990.
[24] D. K. Ghodgaonkar, N. A. Ali, and L. Giub-
bolini, “Microwave nondestructive testing of com-
posite materials using free-space microwave measure-
ment techniques,” in 15th World Conference on Non-
Destructive Testing, Conference Proceedings, pp. 15–
21.
[25] I. S. Seo and W. S. Chin, “Characterization of elec-
tromagnetic properties of polymeric composite mate-
rials with free space method,” Composite Structures,
vol. 66, no. 1-4, pp. 533–542, 2004.
[26] Z. Li, A. Haigh, C. Soutis, and A. Gibson, “Principles
and applications of microwave testing for woven and
non-woven carbon fibre-reinforced polymer compos-
ites: a topical review,” Applied Composite Materials,
vol. 25, no. 4, pp. 965–982, 2018.
[27] K. Lodge, “The electrical properties of joints in car-
bon fibre composites,” Composites, vol. 13, no. 3, pp.
305–310, 1982.
[28] X. Luo and D. Chung, “Electromagnetic interfer-
ence shielding using continuous carbon-fiber carbon-
matrix and polymer-matrix composites,” Composites
Part B: Engineering, vol. 30, no. 3, pp. 227–231,
1999.
[29] S. Kharkovsky and R. Zoughi, “Application of near-
field microwave and millimeter wave nondestructive
testing for evaluation of fiber breakage and orientation
evaluation in cfrp composite patches,” in AIP Confer-
ence Proceedings, vol. 760. AIP, Conference Pro-
ceedings, pp. 554–561.
[30] B. Akuthota, D. Hughes, R. Zoughi, J. Myers, and
A. Nanni, “Near-field microwave detection of dis-
bond in carbon fiber reinforced polymer composites
used for strengthening cement-based structures and
disbond repair verification,” Journal of materials in
civil engineering, vol. 16, no. 6, pp. 540–546, 2004.
[31] S. Kharkovsky, A. C. Ryley, V. Stephen, and
R. Zoughi, “Dual-polarized near-field microwave re-
flectometer for noninvasive inspection of carbon fiber
reinforced polymer-strengthened structures,” IEEE
Transactions on Instrumentation and Measurement,
vol. 57, no. 1, pp. 168–175, 2007.
[32] S.-H. Yang, K.-B. Kim, H. G. Oh, and J.-S. Kang,
“Non-contact detection of impact damage in cfrp
composites using millimeter-wave reflection and con-
sidering carbon fiber direction,” NDT & E Interna-
tional, vol. 57, pp. 45–51, 2013.
9
[33] Z. Li, A. Haigh, C. Soutis, A. Gibson, R. Sloan, and
N. Karimian, “Detection and evaluation of damage in
aircraft composites using electromagnetically coupled
inductors,” Composite Structures, vol. 140, pp. 252–
261, 2016.
[34] S. Gubinelli, E. Paolini, A. Giorgetti, M. Mazzotti,
A. Rizzo, E. Troiani, and M. Chiani, “An ultra-
wideband radar approach to nondestructive testing,”
in 2014 IEEE International Conference on Ultra-
WideBand (ICUWB). IEEE, Conference Proceed-
ings, pp. 303–308.
[35] Z. Li, A. Haigh, C. Soutis, A. Gibson, R. Sloan, and
N. Karimian, “Damage evaluation of carbon-fibre re-
inforced polymer composites using electromagnetic
coupled spiral inductors,” Advanced Composites Let-
ters, vol. 24, no. 3, p. 096369351502400303, 2015.
[36] A. Foudazi, M. T. Ghasr, and K. M. Donnell, “Appli-
cation of active microwave thermography to inspec-
tion of carbon fiber reinforced composites,” in 2014
IEEE AUTOTEST. IEEE, Conference Proceedings,
pp. 318–322.
[37] J. S. Seybold, Introduction to RF propagation. John
Wiley & Sons, 2005.
[38] K. L. Kaiser, Electromagnetic shielding. Crc Press,
2005.
[39] W. B. Westphal and A. Sils, “Dielectric con-
stant and loss data,” MASSACHUSETTS INST OF
TECH CAMBRIDGE LAB FOR INSULATION RE-
SEARCH, Report, 1972.
[40] Y. C. Shin, E. Novin, and H. Kim, “Electrical and
thermal conductivities of carbon fiber composites with
high concentrations of carbon nanotubes,” Interna-
tional Journal of Precision Engineering and Manu-
facturing, vol. 16, no. 3, pp. 465–470, 2015.
[41] D. Balageas, C.-P. Fritzen, and A. Guemes, Structural
health monitoring. John Wiley & Sons, 2010, vol. 90.
[42] R. Chippendale and I. O. Golosnoy, “Percolation ef-
fects in electrical conductivity of carbon fibre com-
posites,” in IET 8th International Conference on Com-
putation in Electromagnetics (CEM 2011). IET, Con-
ference Proceedings, pp. 1–2.
[43] Z. Li, A. Haigh, C. Soutis, and A. Gibson, “X-
band microwave characterisation and analysis of car-
bon fibre-reinforced polymer composites,” Composite
Structures, vol. 208, pp. 224–232, 2019.
[44] D. Chung, “Electromagnetic interference shielding
effectiveness of carbon materials,” carbon, vol. 39,
no. 2, pp. 279–285, 2001.
[45] V. Thierry, L. Brown, and D. Chronopoulos,
“Multi-scale wave propagation modelling for two-
dimensional periodic textile composites,” Composites
Part B: Engineering, vol. 150, pp. 144–156, 2018.
[46] D. Munalli, D. Chronopoulos, and S. Greedy, “Elec-
tromagnetic shielding effectiveness of fiber-reinforced
composites: a preliminary study,” 2018.
[47] D. Munalli, G. Dimitrakis, D. Chronopoulos,
S. Greedy, and A. Long, “Electromagnetic shielding
effectiveness of carbon fibre reinforced composites,”
Composites Part B: Engineering, vol. 173, p. 106906,
2019.
[48] W. Cui, F. Du, J. Zhao, W. Zhang, Y. Yang,
X. Xie, and Y.-W. Mai, “Improving thermal con-
ductivity while retaining high electrical resistivity
of epoxy composites by incorporating silica-coated
multi-walled carbon nanotubes,” Carbon, vol. 49,
no. 2, pp. 495–500, 2011.
[49] T. Weiland, “A discretization model for the solution of
maxwell’s equations for six-component fields,” Archiv
Elektronik und Uebertragungstechnik, vol. 31, pp.
116–120, 1977.
[50] K. Kurokawa, “Power waves and the scattering ma-
trix,” IEEE transactions on microwave theory and
techniques, vol. 13, no. 2, pp. 194–202, 1965.
10
Top Related