PROVEN TECHNOLOGY. PROVEN PROBLEM SOLVER.
THE ONECONSTANTIS CHANGE
When we invented the spiral wound gasket
in 1912, there was nothing like it. 100 years
later, we introduced the ChangeTM gasket-an
incredibly resilient metal-wound gasket that’s
designed to deliver the most dynamic seal
ever. Today there are thousands of ChangeTM
gaskets in service. ChangeTM is manufactured
with proprietary equipment, using a 5X
thicker metal spiral and a unique laser
welding process that penetrates completely
through the winding. Best of all, it’s proven
to perform without fail at least 60% longer
than any other gaskets, CGI Spiral Wound,
Double Jacketed, CMG, or Kammprofile.
AND THAT’S A GAME CHANGER.
ENGINEERED LIKE NOTHING ELSE. TO PERFORM LIKE NOTHING ELSE.
SHAPE> + 5 X Thickness Change
> 304 – 316L & Others
> Develops a Uniquely Solid Gasket
LASER WELDED> Higher unit adhesion
> Pin point accuracy
> Solid unit construction
THE CHANGE GASKET. UNIQUELY MANUFACTURED.
THE CHANGE GASKET IS AVAILABLE WITH A LOCATING RING IN ALL SIZES— UPON REQUEST.
THE FUTURE
IT’S MADE LIKE NO OTHER, SEALS LIKE NO OTHER, &
PERFORMS
60% LONGERCHANGE, IT’S SAFE.
The high level of stored energy gives
the Change gasket extremely high
recovery. In a compression test against
other gaskets, the Change gasket
recovered almost five-times better
than Kammprofile and DJ gaskets.
Spiral Wound GasketFeatures Flexpro (kammprofile) CHANGE Gasket
Blowout Resistant
Excellent Tightness
Excellent Recovery
Cyclic Conditions
Good Handle Ability
Low Seating Stress
Use on Nubbin, when centered
Flexibility Sealing Pipe Flanges
Potential to:Reduce Complexity by
Eliminating Spring Washers
Potential to:Reduce Man Hours
Required for Re-Torque
Potential to:Improve safety by
Eliminating Hot Torquing
Yes, improved with HT Inc X-750
Yes, HT Inc X750 Recommended
Not in all Sizes/Pressure Ratings
Only with HT Inc X750
Only with HT Inc X750
Only with HT Inc X750
Potential Issue
COMPRESSION VS RECOVERYAT 18,000 PSI (124MPA) GASKET STRESS
Gasket Style % Compression % Recovery
Change 30 34
CGI, 316SS 30 26
DJ 26 7
Kammprofile 25 6
CROSS SECTIONAL CUTAWAY
Wound like a spiral. Faced like a kammprofile.
GASKET CONSTANTS
ASME m
ASME Y
PVRC Gb*
PVRC a*
PVRC Gs*
2.5
6,400 psi
1,124 psi
0.25
16 psi
Available Materials
Radial Width
Diameters
Thickness
Standard Windings
Filler & Facing
Outer Ring
Minimum Diameter
Minimum Width
Maximum Diameter
Maximum Width
Carbon steel (other metals available upon request)
0.125” UP TO 30” Max Diameter
0.177” UP TO 130” Max Diameter
1” (for larger widths please contact engineering)
3/8” (for narrower widths please contact engineering)
Round, Oval (up to 24”)
Inconel X750 is available in 0.125” only and Hastelloy C276 is availble in 0.177” only
Corriculite, Flexible graphite, PTFE, and Thermiculite
1” ID
See below
* 304SS/FG
Shapes
304, 316L, 321, 347, Alloy 20, Inconel 625, Monel are available in 0.125”, and 0.177” profile
Across a 24-day, 24-cycle pressure vs thermal cycle test at 608°F (302º C ) replicating industry application conditions, the Change gasket lost just 1.5 PSI. total, never coming close to the failure point. It outperformed every other gasket tested by at least nine days. And there’s no telling how long it would have kept going if we hadn’t stopped the test.
PRESSURE VS. CYCLE NUMBER
• 4” Class 300, RF, B16 studs• Thermal Cycle Phase - Purge and Heat up to 608°F (302°C) at 3.5°F/min (temp chosen so oxidation would not skew results) - Pressurize to 480 psi - Hold 1 hr - Unassisted Cooling to Ambient - Repeat 24 times unless gross failure occurs - Approximately 24 hours per cycle• Record pressure drop every cycle• Max allowable total pressure drop: 14.5 psi
THERMAL CYCLE TEST– 24 CYCLESRefinery specified rig and test represents the potential typical number of temperature fluctuations on a refinery over 4 years with no re-torque
SUCCESSFUL APPLICATION, FERTILIZER INDUSTRY• Superheater exchanger • Change gaskets installed October 2013 and “have withstood” 15 thermal cycles from ambient to 865°F (462°C) during the first 9 months of service• Per operations, they are “still performing well and remain in service.”• NO RE-TORQUING OR HOT TORQUING HAS BEEN REQUIRED• NOx gas & steam • Continuous operating conditions: 865°F (462°C), 150 psi• 36” OD, 304 SS wire, Thermiculite• Replaced Double Jacketed style that failed after 3 cycles
SUCCESSFUL APPLICATION, REFINING• Application cycles from ambient to 715°F (379°C)• Typically experience 28 thermal cycles between major outages requiring several gasket replacements• Change in service since April 2013 with no issues to date and has already out-performed all previously attempted gaskets• 63” diameter Change gasket, 510 psi
SUCCESSFUL APPLICATION, CHEM PROCESSING• Molten Sodium• Operating conditions: 15 psi, 360°F (182°C) with short term cycling to 1500°F (815°C) • Flexible graphite tanged sheet caused a fire • Change gasket safely and effectively sealing several WNRF to Lap Joint NPS flanged connections since November 2013
SUCCESSFUL APPLICATION, BOILER MANWAYS• This steel mill converted all boiler manways to Change gaskets in March 2013• The inherent resiliency of a Change gasket reacts ideally to changing loads when a boiler ramps up or down, expected or not• Improved handling on larger diameter gaskets • Replacing graphite Spirals & tanged sheet
SUCCESSFUL APPLICATION, STEAM PIPING SYSTEM• Change gasket sealing all steam piping and headers since February 2013 in this pulp & paper mill 800°F (427°C), 90 - 215 psi• Replaced standard Spiral Wound gaskets
SUCCESSFUL APPLICATION, SEALING OVER NUBBIN*• Double Jacketed (DJ) gasket continuously leaked in this exchanger sealing steam at 650°F (343°C), 325 psi• Change gasket dimensioned to center and seal over existing nubbin• Per the refinery’s Sr. maintenance engineer, it has been “working without leaks” since July 2013* Providing the gasket is well centered during assembly
CHANGE SUMMARY• Construction is more robust than a Spiral • Creep is VERY low• Recovery is VERY high• Seals with exceptional tightness, especially thermal cycles• Fits most - if not all - flange arrangements• Available in all industrial metals
IT’S BETTER THAN ANY GASKET ON THE MARKET.
EVEN OURS
FLEXITALLIC US, LLC | DEER PARK 6915 Highway 225, Deer Park, TX 77536 USA Phone: +1 281 604 2400 Fax: +1 281 604 2415 Flexitallic.com
FLEXITALLIC US, LLC | GEISMAR 35238 E HWY 30, Geismar, LA 70734 USA Phone: +1 255 442 3580Fax: +1 255 424 6895
FlexitallicLouisiana.com
TO REQUEST WHITE PAPER GO TOFLEXITALLIC.COM
Give us your toughest application.
VER 04172019-LG
Top Related