Component Identification ....................................................................................3 Equipment for Symmetry Residential ................................................................5 Typical Hoistway Options .....................................................................................8 Typical Hoistway Construction ...........................................................................11 Typical Hoistway Overview ................................................................................12 Typical Machine Room Layouts ........................................................................... 13
2
About SymmetryBeautifully Crafted, Expertly Engineered, Thoughtfully Constructed
Symmetry is committed to its quest to develop innovative accessibility products, rigorous in its commitment to beautiful craftsmanship, expert engineering, thoughtful construc-tion, and affordability.
Symmetry is committed to being the leading provider of lift products in North America. We are focused on being your complete lift solutions provider.
Symmetry Elevating Solutions dealer network possesses over 120 combined years of hands-on, real-world home elevator and lift equipment experience.
Symmetry is committed to an unwavering, relentless, honest pursuit of excellence. The result? A visionary product expertly installed, unrivaled in the accessibility industry.
SymmetryElevator.com | 877-375-1428 3
Symmetry Elevating SolutionsNational Reach. Local Service.
At Symmetry, we are your complete lift solutions provider! Please visit us at www.symmetryelevator.com to see our full line of lift solutions.
• ResidentialElevators • Dumbwaiters • Stairlifts • LimitedUse/LimitedAccessElevators • VerticalWheelchairLifts • AutoParkingSolutions-Vasari • VerticalReciprocatingConveyors • AutoGateOperators • MaterialHandlingEquipment • SpecialtyElevatorFixtures • PlannedMaintenanceandService
SymmetryElevator.com | 877-375-1428
COMPONENT IDENTIFICATIONIn-LineGear-DriveOverview
4
Motor Controller DisconnectCab Light Disconnect
Motor ControllerLocated within 50' of the motor
Drive Unit2 H.P. gearmotor with brakeSensorless Flux Vector Controlled
Car Frame
Modular Rail Structure
Roller Chain
Counterweight Assembly
SymmetryElevator.com | 877-375-1428
COMPONENT IDENTIFICATION
5
Modular Rail Structure
Ram Header
(2) 3/8” 7x9
14400# breaking strengthGalvanized Aircraft Cable
Car Frame
Hydraulic Cylinder
Motor Controller Disconnect
Cab Light Disconnect
Motor ControllerLocated within 50’ of the hydraulic power unit
Pedestal Post
Hydraulic Power Unit3 H.P. Submersed Motor / Screw PumpLocated within 40’ of the hydraulic cylinder
Hydraulic-DriveOverview
SymmetryElevator.com | 877-375-1428
Equipment for Symmetry Residential Elevator In-LineGearDrive
6
General•Travel:Maximumof50’(minimum12”betweenstops)•Speed:40FPM•LoadCapacity:950#*OverheadMinimumof8’(96”)withremotecontroller
Minimumof9’withcontrollerinhoistway•Pitdepth:6”minimum(8”preferred)•Twostops•Singleopening•Threeyearlimitedpartswarranty
Mechanical Equipment•Modular61/4#T-railstructure•Carframeassembly•208/230VAC,60Hz,20ampsinglephasepowersupplyfor motor controller•120VAC,60Hz,15ampsinglephasepowersupply for lighting•(2)#60rollerchains•InvertercontrolledvariablespeedIn-LineGearassembly with counterweighted chain drive and 2 H.P. motor* Code compliant electrical disconnects included
Safety Features•Slackchainsafetydevice•Motorcontrollersupply(locatedincontroller)•Carlightsupply(locatedincontroller)•Upperandlowerfinallimits•Pitstopswitch•Cartopstopswitch•In-caremergencystopswitchandalarm•Safetyswitchforcargate(s)•Batterybackupemergencycarlightsandalarm•Electromechanicalhoistwaydoorinterlocks (doorsbyothers)
Controls•ProgrammableLogicController(PLC)•Non-selectivecollectiveautomaticoperation•SelfDiagnosticSystemwithdigitaldisplay•CarOperatingPanel(COP)availableinbrushed stainlesssteelorbrushedbrasswithLEDfloor position indicator•Hallstationsavailableinbrushedstainlesssteelor brushed brass with call button and car arrival indicator•Recessedphoneboxinbrushedstainlesssteelorbrushedbrass(phonejackincluded)•Automaticcarlighting•Singlefloordesignatedcarhoming*UninterruptiblePowerSupply(UPS)forcarloweringandautomaticgateoperation(ifprovided)intheeventof power failure•Manualloweringdevice
Car Features•Cabsizeupto15squarefeet•7’0”interiorcarheight*Birch,Oak,orMapleflatveneerinteriorwallswith matching ceiling•Matchingwoodhandrail* Matching wood car sill•Unfinishedplywoodfloorwithsillsetfor.75” (flooringbyothers)*2energysavingrecessedLEDlightswithblacktrimrings•7’0”vinyllaminateaccordiongate(lightoak,darkoak,white,orantiquewhite)Allaccordiongatesexceptwhitehavebronzehardware.White gates have aluminum hardware.
Optional Features•UptoSixstops•Singleautomaticpushbuttonoperation•Customcarsizeupto18squarefeet**
•Customcarheights•Insetpanelcarwithflushceiling•Insetpanelcarwithmatchingceiling•Raisedpanelcarwithmatchingceiling*4recessedLEDlightswithblacktrimrings•Factoryfinishedcar•Polishedstainlesssteel,polishedbrass,brushednickel,vintagebronzeandoilrubbedbrassfixtures(includingCOP,phonebox,hallcalls,andhandrail)* COP with integrated phone box•Customwoodinteriors*Customfactoryfinishes(antiqued,distressed,&crackle)*Greenmaterialalternativesandfinishesforcarinteriors•Scissorgate•Hardwoodveneeraccordiongate•Clearpanelaccordiongate•Autogateoperator(availableforusewithaccordion gateonly)•.75”finishedorunfinishedfactoryinstalledhardwood carflooring•Factoryflooringinsertfor1/4”flooringbyothers•Buffersprings(requiresminimumof10”pitdepth)•KeyswitchforCOPandhallstations•750#carcapacity
* This symbol denotes exclusive features** May require local code authority approval
SymmetryElevator.com | 877-375-1428
Equipment for Symmetry Residential Elevator HydraulicDriveSystem
7
General•Travel:Maximumof50’(minimum12”betweenstops)•Speed:40FPM•LoadCapacity:950#*OverheadMinimumof8’(96”)withremotecontroller•Pitdepth:6”minimum(8”preferred)•Twostops•Singleopening•Threeyearlimitedpartswarranty
Mechanical Equipment•Modular61/
4#T-railstructure
•Carframeassembly•208/203VAC,60Hz,30ampsinglephasepowersupplyfor motor controller•120VAC,60Hz,15ampsinglephasepowersupply for lighting•(2)3/
8”7x19galvanizedaircraftcable(14400#breaking
strength)withwedgeropeshackles•80mmdiameterpiston/102mmdiametercylinderincl.1”- 3/
4”reducerbushing
•Screwpump(300micronscreen)•Positive pressure switch* Code compliant electrical disconnects included
Safety Features•Slackropesafetydevice•Motorcontrollersupply(locatedincontroller)•Carlightsupply(locatedincontroller)•RuptureValve(Type“C”Safety)•Pitstopswitch•Cartopstopswitch•In-caremergencystopswitchandalarm•Safetyswitchforcargate(s)•Batteryback-upemergencycarlightsandalarm•Electromechanicalhoistwaydoorinterlocks (doorsbyothers)
Controls•ProgrammableLogicController(PLC)•Non-selectivecollectiveautomaticoperation*SelfDiagnosticSystemwithdigitaldisplay•CarOperatingPanel(COP)availableinbrushed stainlesssteelorbrushedbrasswithLEDfloor position indicator•Hallstationsavailableinbrushedstainlesssteelor brushed brass with call button and car arrival indicator•Recessedphoneboxinbrushedstainlesssteelorbrushedbrass(phonejackincluded)•Automaticcarlighting•Singlefloordesignatedcarhoming*UninterruptiblePowerSupply(UPS)forcarloweringandautomaticgateoperation(ifprovided)intheeventof power failure
Car Features•Cabsizeupto15squarefeet•7’0”interiorcarheight*Birch,Oak,orMapleflatveneerinteriorwallswith matching ceiling•Matchingwoodhandrail* Matching wood car sill•Unfinishedplywoodfloorwithsillsetfor.75” (flooringbyothers)*2energysavingrecessedLEDlightswithblacktrimrings•7’0”vinylaccordiongate(lightoak,darkoak,white,orantiquewhite)
Optional Features•UptoSixstops•Singleautomaticpushbuttonoperation•Customcarsizeupto18squarefeet**
•Customcarheights•Insetpanelcarwithflushceiling•Insetpanelcarwithmatchingceiling•Raisedpanelcarwithmatchingceiling*4recessedLEDlightswithblacktrimrings•Factoryfinishedcar•Polishedstainlesssteel,polishedbrass,brushednickel,vintagebronzeandoilrubbedbrassfixtures(includingCOP,phonebox,hallcalls,andhandrail)* COP with integrated phone box•Customwoodinteriors*Customfactoryfinishes(antiqued,distressed,&crackle)*Greenmaterialalternativesandfinishesforcarinteriors•Scissorgate•Hardwoodveneeraccordiongate•Clearpanelaccordiongate•Autogateoperator(availableforusewithaccordion gateonly)•.75”finishedorunfinishedfactoryinstalledhardwood carflooring•Factoryflooringinsertfor1/4”flooringbyothers•Buffersprings(requiresminimumof10”pitdepth)•KeyswitchforCOPandhallstations•750#carcapacity
* This symbol denotes exclusive features** May require local code authority approval
SymmetryElevator.com | 877-375-1428
Hoistway Construction Outline:
• FURNISH APPROPRIATE RAIL BACKING FOR T-RAIL • CONSULT DEALER FOR SPAN OF GREATER THAN 10’ BETWEEN FLOOR JOISTS • MAINTAIN BELOW 1/8” TOLERANCES THROUGHOUT HOISTWAY • RAIL BACKING WALL MUST BE A LOAD BEARING WALL • PIT FLOOR MUST BE A MINIMUM OF 6” (8” PREFERRED) BELOW THE FINISHED FLOOR OF THE LOWEST LANDING. CONFIRM PIT DEPTH WITH ELEVATOR CONTRACTOR PRIOR TO CONCRETE POUR • CONSTRUCTION OF PIT FLOOR MUST WITHSTAND AN IMPACT LOAD OF 4000#, STATIC LOAD 2400# (950# CAPACITY) • 8’0” MINIMUM HOISTWAY OVERHEAD ABOVE THE FINISHED FLOOR AT THE TOP LANDING IS REQUIRED FOR 7’0” CAR WITH REMOTE CONTROLLER • 9’0” MINIMUM HOISTWAY OVERHEAD ABOVE THE FINISHED FLOOR AT THE TOP LANDING IS REQUIRED FOR 7’0” CAR WITH CONTROLLER LOCATED IN THE HOISTWAY • PROVIDE AN ACCESS HATCH FOR SERVICING THE CONTROLLER/DRIVE UNIT ON IN-LINE GEAR DRIVE ELEVATOR
• HATCH TO ACCESS MOTOR BRAKE ON UNITS WITH REMOTE CONTROLLER • HOISTWAY DOORS PROVIDED BY OTHERS. MINIMUM 3’0” X 6’8” SOLID CORE DOORS ARE RECOMMENDED • HOISTWAY MUST BE FREE OF ANY OBSTRUCTIONS UNRELATED TO THE ELEVATOR OPERATION (I.E. SPRINKLERS, PIPES, DUCTS, ETC,) • THE STRUCTURE OF THE HOISTWAY MUST ALLOW FOR INSTALLATION OF A CHAIN HOIST TO TRANSFER MATERIALS TO THE UPPER LANDINGS DURING ELEVATOR INSTALLATION
* This guide is for planning purposes only. This guide is NOT intended for construction purposes. Prior to construction, please request a job specific set of elevator plans to ensure correct and accuratedimensionsandrequirementsforyourproject.
*YourlocalSymmetryrepresentativewillassistyouinensuringyourprojectspecificplans will comply with your local and state codes and building authority.
8
SymmetryElevator.com | 877-375-1428
Typical Hoistway OptionsAllHoistwayDimensionsReferenceFinishedWalltoFinishedWall
9
DEPTH
WID
TH
RAIL C/L
STRUCTURE
DO
OR
C/L
DEP
TH
DEP
TH
WIDTH WIDTHRAIL C/L RAIL C/L
STRUCTURESTRUCTURE
DOOR C/L DOOR C/L
DEPTH
WID
TH
RAIL C/L
STRUCTURE
DO
OR
C/L
SINGLE OPENING, RAIL LEFT, RIGHT HAND DOOR OR RAIL RIGHT/LEFT HAND DOOR SINGLE OPENING, RAIL LEFT, LEFT HAND DOOR OR RAIL RIGHT/RIGHT HAND DOOR
SINGLE OPENING, RAIL FRONT, LEFT HAND DOOR OR RAIL FRONT/RIGHT HAND DOOR SINGLE OPENING, RAIL FRONT, LEFT HAND DOOR OR RAIL FRONT/RIGHT HAND DOOR
36 x 48 50½” 54½” 27¼” 28¾” 32¼”
36 x 60 50½” 66½” 33¼” 28¾” 32¼”40 x 54 54½” 60½” 30¼” 32¾” 33½”
36 x 48 54” 54½” 27¼” 28¾” 32¼”
36 x 60 54” 66½” 33¼” 28¾” 32¼”
40 x 54 55” 60½” 30¼” 28¾” 33½”
36 x 48 48” 62½” 23¼” 23¼” 32¼”
36 x 60 48” 74½” 23¼” 23¼” 32¼”
40 x 54 48” 68½” 24” 21¾” 33½”
48 x 36 54½” 50½” 27¼” 20¾” 32¼”
60 x 36 66½” 50½” 33¼” 20¾” 32¼”
54 x 40 60½” 54½” 30¼” 20¾” 32¼”
Car Size Width Depth Rail C/L Door C/L Clear Opening
Car Size Width Depth Rail C/L Door C/L Clear Opening
Car Size Width Depth Rail C/L Door C/L Clear Opening
Car Size Width Depth Rail C/L Door C/L Clear Opening
DOOR CENTERLINES ARE SHOWN WITH 3’0” DOORS. PLEASE CONSULT MANUFACTURER FOR ALTERNATE DOOR WIDTHS
SymmetryElevator.com | 877-375-1428
Typical Hoistway OptionsAllHoistwayDimensionsReferenceFinishedWalltoFinishedWall
10
OPPOSITE OPENING, RAIL LEFT, RIGHT HAND DOOR OR RAIL RIGHT/LEFT HAND DOOR OPPOSITE OPENING, RAIL LEFT, LEFT HAND DOOR OR RAIL RIGHT/RIGHT HAND DOOR
90 DEGREE OPENING, RAIL FRONT, LEFT HAND DOOR OR RAIL FRONT/RIGHT HAND DOOR 90 DEGREE OPENING, RAIL FRONT, LEFT HAND DOOR OR RAIL FRONT/RIGHT HAND DOOR
36 x 48 50½” 54½” 27¼” 28¾” 32¼”
36 x 60 50½” 66½” 33¼” 28¾” 32¼”40 x 54 54½” 60½” 30¼” 32¾” 33½”
36 x 48 54” 54½” 27¼” 28¾” 32¼”
36 x 60 54” 66½” 33¼” 28¾” 32¼”
40 x 54 55” 60½” 30¼” 28¾” 33½”
36 x 48 50½” 55” 27¾” 25”/28½” 32¼”
36 x 60 50½” 67” 33¾” 25”/40½” 32¼”
40 x 54 54½” 61” 30¾” 29”/34½” 32¼”
36 x 48 50½” 55” 27¾” 25”/28½” 32¼”
36 x 60 50½” 67” 33¾” 25”/40½” 32¼”
40 x 54 54½” 61” 30¾” 29”/34½” 32¼”
Car Size Width Depth Rail C/L Door C/L Clear Opening
Car Size Width Depth Rail C/L Clear Opening
Car Size Width Depth Rail C/L Door C/L Clear Opening
Car Size Width Depth Rail C/L
Clear Opening
DOOR CENTERLINES ARE SHOWN WITH 3’0” DOORS. PLEASE CONSULT MANUFACTURER FOR ALTERNATE DOOR WIDTHS
DEPTH
WID
TH
RAIL C/L
STRUCTURE
DO
OR
C/L
DO
OR
C/L
DEPTH DEPTH
WID
TH
WID
TH
RAIL C/L RAIL C/L
STRUCTURE STRUCTURE
DOOR C/L
DO
OR
C/L
DOOR C/L
DEPTH
WID
TH
RAIL C/L
STRUCTURE
DO
OR
C/L
DO
OR
C/L
Door C/L A+B
Door C/L A+B
AA
BB
SymmetryElevator.com | 877-375-1428
Typical Hoistway OptionsAllHoistwayDimensionsReferenceFinishedWalltoFinishedWall
11
90 DEGREE OPENING, RAIL LEFT, LEFT HAND DOOR / RIGHT HAND DOOR 90 DEGREE OPENING, RAIL RIGHT, LEFT HAND DOOR / LEFT HAND DOOR
36 x 48 50½” 55” 27¾” 29¼/33¼” 28½”/32¼”
36 x 60 50½” 67” 33¾” 29¼/45¼” 28½”/32¼”
40 x 54 54½” 61” 30¾” 29¼/39¼” 32¼”
36 x 48 50½” 55” 27¾” 25”/33¼” 32¼”
36 x 60 50½” 67” 33¾” 25”/45¼” 32¼”
40 x 54 54½” 61” 30¾” 29”/39¼” 32¼”
Car Size Width Depth Rail C/L
Clear Opening Car Size Width Depth Rail C/L Clear
Opening
DEPTH
WID
TH
RAIL C/L
STRUCTURE
DO
OR
C/L
DOOR C/L
DEPTH
WID
TH
RAIL C/L
STRUCTURE
DO
OR
C/L
DOOR C/L
DOOR CENTERLINES ARE SHOWN WITH 3’0” DOORS. PLEASE CONSULT MANUFACTURER FOR ALTERNATE DOOR WIDTHS
DOOR C/LA + B
DOOR C/LA + B
A A
B B
SymmetryElevator.com | 877-375-1428
Typical Hoistway ConstructionConstruction&RailBackingDetails
12
T-RAILREACTIONS
950#R1=190R2=350
Typical Rail BackingConstruction
PIT FLOOR LOADSImpact Load 4000 lbs Static Load 2400 lbs (950# Capacity)
PIT FLOOR DEPTH = 6” minimum required (8” preferred)
10' M
AX
Allow fordrywallthickness
hoistway)Pit wall
10"10"
10"10"
RailBackingCenterline
Drywall
Construction Detailsof Rail Backing:• Laminate (2) 2x10's and (2) 2x4's using wood glue and #8x2-3/4" screws.• All joints must be staggered.
Corner PostConstruction
Header
Floor Joists
Typical HoistwayConstruction Details
2 x 4
2 x 4
2 x 4
2 x 10 ’ s
2 x 10 ’ s
2 x 4
• Laminate (2) 2x10's and (2) 2x4's using wood glue and #8x2-3/4" screws.• All joints must be staggered.
RECOMMENDED:For superior structural and acoustic
performance, 1/2” plywood is recommendedunderneath the drywall on the rail wall
CENTERLINE OFRAIL BACKING
12" vertical screwspacing and 2" fromeach side o� 2x10centerline
Drywall(shown cutaway)
• For span exceeding 10’ max of travel contact your Symmetry elevator contractor.
FOR FIRE RATING REQUIREMENTS - CHECK LOCAL JURISDICTION
SymmetryElevator.com | 877-375-1428
Typical Hoistway Overview
13
RailBacking
CENTERLINE OFRAIL BACKING
10" 10"
Typical Framework with Drywall Construction
3" MAX* (INSIDE FACE OFHOISTWAY DOOR TO SILL)
*Dimensions are required by ASME A17.1
.5” - 1.5”* RUN CLR (SILL TO SILL)
TYPICAL DOOR LOCATION DETAIL** HORIZONTAL RUNNING CLEARANCES AS
REQUIRED BY ASME A17.1, SECTION 5.3
(LEFT HAND DOOR SHOWN)
.25" Thick MullCasing insideHoistway
2 1/2" REQUIREDINSIDE FACE OF DOORTO FACE OF DRYWALL(3" TO HOISTWAY SILL)
ELEVATORGATE
cove
r rev
eal o
utsi
de o
f jam
b)
Notes:1) 8’0” Overhead required for 7’0” Interior Cab Height for Hydraulic and Remote Controller In-Line Gear.
9’0” Overhead required for 7’0” Interior Cab Height for In-Line Gear with Controller in the Hoistway. (Includes 9” of Cartop Clearance.)
2) Minimum Floor to Floor Travel is 12” between Floors (If Travel is Less than 12” Consult Factory).
Maximum Floor to Floor Travel: 950lb Unit = 50’0”
3) Minimum Pit Depth is 6” (8” preferred) Impact Load @ Pit 6500lbs (950lb Capacity) Static Load @ Pit 3800lbs (950lb Capacity) Bu�er Springs require 10” Pit Depth Minimum.
4) Consult Local Authority to Ensure Compliance with State and Local Codes.
5) The Hoistway is required to be Free of all Pipes, Wiring, and Obstructions not related to the Operation of the Elevator.
Car Height Remote Controller Controller in Hoistway
7’0” 8’0” (96”) 9’0” (108”)
7’11” 8’11” (107”) 9’11” (119”)
OVERHEAD CLEARANCE REQUIREMENTS
(Hydraulic & IGD) (Hydraulic & IGD) (IGD Only)
6’8”
HO
ISTW
AY O
PEN
ING
6’8”
HO
ISTW
AY O
PEN
ING
6’8”
HO
ISTW
AY O
PEN
ING
6’8”
HO
ISTW
AY O
PEN
ING
7’0”
INSI
DE
HEI
GH
T
2” O
VER
TRAV
EL
OVE
RALL
HO
ISTW
AY -
SEE
NO
TE (5
)(P
IT+T
RAVE
L+O
VERH
EAD
)
4”
TOTA
L CA
R TR
AVEL
- SE
E N
OTE
(2)
OVE
RHEA
D -
SEE
NO
TE (1
)
PIT
- SEE
NO
TE (3
)
SymmetryElevator.com | 877-375-1428
Typical Machine Room LayoutsIn-LineGearDrive
14
IN-LINE GEAR DRIVE WITH REMOTE CONTROLLER IN MACHINE ROOM
Machine Stop SwitchManual Brake Release
Manual Lowering Access
Drive Unit
Door Interlock
Hoistway DoorTravel Cable
Rail Structure
Please note that this layout is shown for manual lowering access at the top right of the view. The drive unit can be mounted opposite to accommodate access.
Notes:• Minimum overhead clearance as measured from the top of the upper most landing sill to the bottom of the shaft ceiling is 8' - 0" for a standard 7' - 0" car.
REMOTE CONTROLLER MACHINE ROOM LAYOUT
230VAC, 20 AMP, Single Phase(3 Wire Dedicated Circuit)*Feeding breaker must not be a G.F.I.
Car Light Disconnect(Fusible and Lockable)
Motor Controller Disconnect(Fusible and Lockable)
Motor Controller
Telephone Service For Elevator
115VAC, 15 AMP, Dedicated Single Phase*Feeding breaker must not be a G.F.I.
30" wide x 36" deep clear workingspace required in front of theMotor Controller by NEC.
Lockable Remote Controller Cabinet(18" wide x 18" high x 10" deep)Must be located within 50' of the drive unit.
CONSTRUCTION OF MACHINE ROOMS MUST ADHERE TO LOCAL, STATE, AND NATIONAL CODES.
30”
36”
Front View
TopView
SymmetryElevator.com | 877-375-1428
Typical Machine Room LayoutsIn-LineGearDrive
15
IN-LINE GEAR DRIVE WITH CONTROLLER IN HOISTWAY230VAC, 20 AMP, Single Phase
(3 Wire Dedicated Circuit)*Feeding breaker must not be a G.F.I.
Car Light Disconnect(Fusible and Lockable)
Motor Controller Disconnect(Fusible and Lockable)
Motor Controller
Travel Cable
Rail Structure
Please note that this layout is shown for manual lowering access at the top right of the view. The drive unit can be mounted opposite to accommodate access.Notes:• Minimum overhead clearance as measured from the top of the upper most landing sill to the bottom of the shaft ceiling is 8' - 0" for a standard 7' - 0" car.
Hoistway DoorDoor Interlock
Manual Lowering Access
Drive UnitManual Brake Release
Machine Stop SwitchService Light Switch
115 VAC G.F.I. Duplex Receptacle(Must be separate from elevator circuits)
Telephone Service For ElevatorPlastic Coated Service Light Bulb With Guard
115VAC, 15 AMP, Dedicated Single Phase*Feeding breaker must not be a G.F.I.
MANUAL LOWERING ACCESS HATCH DETAIL
Rail Wall on a LHHoistway
Service AccessDoor---Use
Self-Closing Hinges.
Cent
er o
f Acc
ess
Doo
r
Upper LandingHoistway Door
Hall Station
CENTERLINE OF ACCESS DOOR
Cab Height: 6-8 7-0 7-2 7-11 8-0Dim. To door: 88" 90" 92" 101" 102"
CONSTRUCTION OF MACHINE ROOMS MUST ADHERE TO LOCAL, STATE, AND NATIONAL CODES.
(REQUIRED FOR ALLIGD APPLICATIONS)
ACCESSHATCHDETAIL
• This layout is shown for manual lowering access at the top right of the view. The drive unit can be mounted opposite to accommodate access.
SymmetryElevator.com | 877-375-1428
Typical Machine Room LayoutsHydraulicDrive-StandardMachineRoom
16
5) MAXIMUM 360 DEGREES IN HARD PIPE BENDS.
MAIN HYDRAULICCONTROL BOX
HYDRAULIC POWER UNIT
SymmetryElevator.com | 877-375-1428
Typical Machine Room LayoutsHydraulicDrive-CompactMachineRoom
17
MAIN HYDRAULICCONTROL BOX
HYDRAULIC POWER UNIT
SymmetryElevator.com | 877-375-1428
Part 1 General1.01 Scope
The scope of this section of work is the provision of and installation - residential elevator and all the necessary equipment required to fully complete the installation and coordinate between the other associated work required by other trades. The equipmentspecificationsarebasedontheSymmetryElevatingSolutionsproductdesign–In-LineGearDrive–IGDdrive system with cantilever sling.
1.02 References
A. Elevator equipment shall be designed, manufactured, installed and maintained in compliance and accordance with the followingNationalandlocalStandards:VerifywithlocalAHJ.
1.AmericanNationalStandardsInstitute–ANSIA117.13.ICC/IBC-InternationalBuildingCode-Chapter301.NFPA70- 1999NationalElectricalCode-NECChapter620”
2.AmericanSocietyofMechanicalEngineers-ASMEA17.1Part5.3PrivateResidenceElevators
3.ICC/IBC–InternationalBuildingCodesA117.1
4.NFPA70-1999NationalElectricalCode–NEC
1.03 Quality Assurance
A. Elevator equipment shall be designed and tested to meet or exceed the above standards and provide the following specificcomponents.AllloadratingsandsafetyfactorsshallmeetorexceedthosespecifiedbylocalAHJandbecertifiedby an independent professional engineer.
B.ElevatorInstaller/contractorshallbecertifiedtoinstalltheequipmentbytheManufacturerandhavetheappropriate Local, State or National certifications to install this specific style of equipment. A minimum of 10 years industry experience. Shall be Insured to perform this type work including product and public liability insurance. Copies of current Certificates of Insurance shall be provided with the contract prior to the start of work.
C.ElevatorInspectionshallbeperformedpriortoturnovertoowner.InspectionshallbeperformedbythelocalAHJora competentpersontrainedtoperformthistypeinspectiontocomplywithAMSEA17.2asitrelatestopart5.3Private Residence Elevators.
1.04 Warranty
A. The Manufacturer shall warranty component parts of the Symmetry Elevating Solutions equipment for a period of 3 – Three yearsfromcompletionofelevatorinstallation.(SubmitWarrantydetailswithOwnersManual)
B.AqualifiedMaintenanceProgram,complyingwiththemanufacturer’srecommendedmaintenanceschedule,isrequiredduringthethree(3)yearperiodinordertomaintainthewarranty.
2.01 Product
General:
•Travel:Maximumof50’(minimum12”betweenstops)Actualtravel:_________feet______inches
•Speed:40FPM
•LoadCapacity:950#(upto50’oftravel)
•Overhead:Minimumof8’6”(102”)
•Pitdepth:6”minimum
•FloorsServed____2____3____4____5____6
•Cabentrance______Singleopening______Oppositeopenings_______90degree/Adjacentopenings
•Threeyearlimitedpartswarranty
18
Section 14205 - Bid SpecificationsResidential Elevator - In-Line Gear Drive
SymmetryElevator.com | 877-375-1428
2.02 Mechanical EquipmentMechanicalEquipmentandDrive:In-LineGearDrive
•Modular61/4#T-railstructure
•Carframeassembly:Cantilever
•208/230VAC,60Hz,20ampsinglephasepowersupplyformotorcontroller
•120VAC,60Hz,15ampsinglephasepowersupplyforlighting
•(2)#60rollerchainsuspensionmeans
•InvertercontrolledvariablespeedgearedassemblywithIn-LineGeardriveunitand2H.P.motor.
*Code compliant electrical disconnects included
2.03 Safety Devices:
•Slackchainsafetydevice
•Motorcontrollersupplydisconnect(locatedincontroller)
•Carlightsupplydisconnect(locatedincontroller)
•Pitstopswitch
•Cartopstopswitch
•In-caremergencystopswitchandalarm
•Safetyswitchforcargate(s)
•Batterybackupemergencycarlightsandalarm
•Electromechanicalhoistwaydoorinterlocks(doorsbyothers)
•UninterruptiblePowerSupply–(UPS)forcarloweringandautomaticgateoperation(ifautogateoperatorprovided)inthecaseofpowerfailure(toallowemergencylowerofcabincaseofmainpowerfailure)
2.04 Controls:
•ProgrammableLogicController(PLC)
•Non-selectivecollectiveautomaticoperation
•SelfDiagnosticSystemwithdigitaldisplay(ateachlandingandincar)
•CarOperatingPanel(COP)withLEDfloorpositionindicator–Finishesseesection2.05
•Hallstationswithcallbuttonandcararrivalindicator.–Finishesseesection2.05
•Recessedphoneboxinsamefinishabove(phonejackincluded)–Finishesseesection2.05
•Automaticcarlighting
•Singlefloordesignatedcarhoming
UninterruptiblePowerSupply(UPS)forcarloweringandautomaticgate
operation(ifprovided)intheeventofpowerfailure
2.05 Metal Finishes
CarOperatingpanel,Hallcallstations&phoneboxareavailablein_____brushedstainlesssteel_____BrushedBrass_____Black____VintageBronzePowdercoat.Standardfinishes
OptionalFinishselections:_____PolishedStainlessSteel____PolishedBrass____Nickel___OilRubbedbrass.Customfinishrequest_________________ 19
Section 14205 - Bid SpecificationsResidential Elevator - In-Line Gear Drive
SymmetryElevator.com | 877-375-1428
2.06 Car Features:•Cabsizeupto18squarefeet
•7’0”interiorstandardcarheight;____7’11”optionalinteriorcarheightat“nocharge”;Customcarheights______to9’0”
Interior Car Wall styles
A.FlatveneerinteriorwallswithmatchingceilingandMatchingwoodcarsill__________
B.ShakerstyleinteriorwallswithmatchingceilingandMatchingwoodcarsill_________
C.InsetstyleinteriorwallswithmatchingceilingandMatchingwoodcarsill_______
D.RaisedstyleinteriorwallswithmatchingceilingandMatchingwoodcarsill______
E.Customdesigninteriorwallpanels,ceiling&sill______
(Selectonestyleinteriorwallpanelfromabove.)
•Unfinishedplywoodfloorwithsillsetfor3/4”(flooringbyothers)
Customflooring____________________
•2energysavingrecessedwithblacktrimrings
•7’0”vinylaccordiongate(lightoak,darkoak,white,orantiquewhite)
OptionalRealhardwoodveneeraccordiongatepanels_____________________Choosefromsamplekit.
Allaccordiongatesexceptwhitehavebronzehardware.White gates have aluminum hardware.
2.07 Optional Features:
•Insetpanelcarwithmatchingceiling
•Raisedpanelcarwithmatchingceiling
•4recessedLEDlightswithblacktrimrings
•Factoryfinishedcarwallpanels_________________Stain#_________________Finish
•COPwithintegratedphonebox
•Customwoodinteriors
•Customfactoryfinishes(antiqued,distressed,&crackle)
•Greenmaterialalternativesandfinishesforcarinteriors
•Scissorgate
•Hardwoodveneeraccordiongate
•Clearpanelaccordiongate_______Allpanels________3centerpanels
•Autogateoperator(availableforusewithaccordiongateonly)
•3/4”finishedorunfinishedfactoryinstalledhardwoodcarflooring
•Factoryflooringinsertfor1/4”flooringbyothers
•Buffersprings(requiresminimumof10”pitdepth)
•Upperandlowerfinallimits,inadditiontoNormalupanddownlimits
•KeyswitchforCOPandhallstations
•750#carcapacity
20
Section 14205 - Bid SpecificationsResidential Elevator - In-Line Gear Drive
SymmetryElevator.com | 877-375-1428
3.01 Work By Others:Theinstallationoftheelevatorandits’hardwareistheresponsibilityoftheElevatorContractor.Theinstallationandpreparationofa suitable hoistway, main power, door installation, pit construction and structural support are Work by Others
A. Hoistway shall be constructed from dimensional lumber, concrete or concrete block to support loads listed in the shop drawings with elevator rail reaction and pit loading consideration by others. The hoistway must be plumb and square within 1/4”toptobottomandsidetoside.
B.Allstructuralmemberlocationsinthehoistwaywallsareperthemanufacturer’sshopdrawings.
C.DoorcenterlinesarelistedontheshopdrawingsandareNOTtheCenterofthehoistway.
D.Mainpowerfromthemainbreakerpaneltotheelevatorlocationshownintheshopdrawingsis“byothers”.Equipment disconnects are included with the controller.
E.Installationofalivephonelineandoutlettotheelevatorlocation,asshownontheshopdrawings,iswork“byothers”.
F.MachineSpaceofapprox.4’x5’(orasrequiredbylocalAHJ)shallbeprovidedonalowerfloortocontainthecontrollerand pump unit. The requirements for this room will be shown on the shop drawings and coordinated with the various trades priortofabrication.(Seeshopdrawingsforlayout)
G.CompactmachinespacesasallowedbylocalAHJtopconformwithmanufacturersfabrication.(Seeshopdrawingsfor layout)
H. Pre-wire in the walls shall be coordinated with the builder prior to wall construction and drywall installation.
End of Section
21
Section 14205 - Bid SpecificationsResidential Elevator - In-Line Gear Drive
SymmetryElevator.com | 877-375-1428
Part 1 General1.01 Scope
The scope of this section of work is the provision of and installation - residential elevator and all the necessary equipment required to fully complete the installation and coordinate between the other associated work required by other trades. The equipmentspecificationsarebasedontheSymmetryElevatingSolutionsproductdesign–Hydraulic1:2ropeddrivesystemwith cantilever sling.
1.02 References
A. Elevator equipment shall be designed, manufactured, installed and maintained in compliance and accordance with the followingNationalandlocalStandards:VerifywithlocalAHJ.
1.AmericanNationalStandardsInstitute–ANSIA117.13.ICC/IBC-InternationalBuildingCode-Chapter301.NFPA70- 1999NationalElectricalCode-NECChapter620”
2.AmericanSocietyofMechanicalEngineers-ASMEA17.1Part5.3PrivateResidenceElevators
3.ICC/IBC–InternationalBuildingCodesA117.1
4.NFPA70-1999NationalElectricalCode–NEC
1.03 Quality Assurance
A. Elevator equipment shall be designed and tested to meet or exceed the above standards and provide the following specificcomponents.AllloadratingsandsafetyfactorsshallmeetorexceedthosespecifiedbylocalAHJandbecertifiedby an independent professional engineer.
B.ElevatorInstaller/contractorshallbecertifiedtoinstalltheequipmentbytheManufacturerandhavetheappropriate Local, State or National certifications to install this specific style of equipment. A minimum of 10 years industry experience is required to perform this type work including product and public liability insurance. Copies of current Certificates of Insurance shall be provided with the contract prior to the start of work.
C.ElevatorInspectionshallbeperformedpriortoturnovertoowner.InspectionshallbeperformedbythelocalAHJora competentpersontrainedtoperformthistypeinspectiontocomplywithAMSEA17.2asitrelatestopart5.3Private Residence Elevators.
1.04 Warranty
A.TheManufacturershallwarrantycomponentpartsoftheSymmetryElevatingSolutionsequipmentforaperiodofthree(3)yearsfromcompletionofelevatorinstallation.(SubmitWarrantydetailswithOwnersManual)
B.AqualifiedMaintenanceProgram,complyingwiththemanufacturer’srecommendedmaintenanceschedule,isrequiredduringthethree(3)yearperiodinordertomaintainthewarranty.
2.01 Product
General:
•Travel:Maximumof50’(minimum12”betweenstops)Actualtravel:_________feet______inches
•Speed:40FPM
•LoadCapacity:950#(upto50’oftravel)
•Overhead:Minimumof8’(96”)
•Pitdepth:6”minimum
•FloorsServed____2____3____4____5____6
•Cabentrance______Singleopening______Oppositeopenings_______90degree/Adjacentopenings
•Threeyearlimitedpartswarranty
22
Section 14205 - Bid SpecificationsResidential Elevator - 1:2 Roped Hydraulic
SymmetryElevator.com | 877-375-1428
2.02 Mechanical EquipmentMechanicalEquipmentandDrive:1:2RopedHydraulic
•Modular61/4#T-railstructure
•Carframeassembly:Cantilever
•208/230VAC,60Hz,15ampsinglephasepowersupplyformotorcontroller
•120VAC,60Hz,15ampsinglephasepowersupplyforlighting
•(2)3/8”7x19galvanizedaircraftcable(14400#breakingstrength)withwedgeropeshackles
•80mmdiameterpiston/102mmdiametercylinderincl.1”-3/4”reducerbushing
•208/230,3H.P.submersedmotorwith2-speedvalveassembly(1750RPM,17FLAmps)-Manualdownvalveforemergencylowering
•ScrewPump(300micronscreen)
•Positivepressureswitch
*Code compliant electrical disconnects included
2.03 Safety Devices:
•Slackropesafetydevice
•Rupturevalve(type“C”safety)
•Motorcontrollersupplydisconnect(locatedincontroller)
•Carlightsupplydisconnect(locatedincontroller)
•Pitstopswitch
•Cartopstopswitch
•In-caremergencystopswitchandalarm
•Safetyswitchforcargate(s)
•Batterybackupemergencycarlightsandalarm
•Electromechanicalhoistwaydoorinterlocks(doorsbyothers)
•UninterruptiblePowerSupply–(UPS)forcarloweringandautomaticgateoperation(ifautogateoperatorprovided)inthecaseofpowerfailure(toallowemergencylowerofcabincaseofmainpowersupply)
2.04 Controls:
•ProgrammableLogicController(PLC)
•Non-selectivecollectiveautomaticoperation
•SelfDiagnosticSystemwithdigitaldisplay(ateachlandingandincar)
•CarOperatingPanel(COP)withLEDfloorpositionindicator–Finishesseesection2.05
•Hallstationswithcallbuttonandcararrivalindicator.–Finishesseesection2.05
•Recessedphoneboxinsamefinishabove(phonejackincluded)–Finishesseesection2.05
•Automaticcarlighting
•Singlefloordesignatedcarhoming
•Lowoilruntimer
23
Section 14205 - Bid SpecificationsResidential Elevator - 1:2 Roped Hydraulic
SymmetryElevator.com | 877-375-1428
2.05 Metal Finishes:CarOperatingpanel,Hallcallstations&phoneboxareavailablein_____brushedstainlesssteel_____BrushedBrass_____Black____VintageBronzePowdercoat.Standardfinishes
OptionalFinishselections:_____PolishedStainlessSteel____PolishedBrass____Nickel___OilRubbedbrass.Customfinishrequest_________________
2.06 Car Features:•Cabsizeupto18squarefeet
•7’0”interiorstandardcarheight;____7’11”optionalinteriorcarheightat“nocharge”;Customcarheights______to9’0”
Interior Car Wall styles
A.FlatveneerinteriorwallswithmatchingceilingandMatchingwoodcarsill__________
B.ShakerstyleinteriorwallswithmatchingceilingandMatchingwoodcarsill_________
C.InsetstyleinteriorwallswithmatchingceilingandMatchingwoodcarsill_______
D.RaisedstyleinteriorwallswithmatchingceilingandMatchingwoodcarsill______
E.Customdesigninteriorwallpanels,ceiling&sill______
(Selectonestyleinteriorwallpanelfromabove.)
•Unfinishedplywoodfloorwithsillsetfor3/4”(flooringbyothers)
Customflooring____________________
•2energysavingrecessedwithblacktrimrings
•7’0”vinylaccordiongate(lightoak,darkoak,white,orantiquewhite)
OptionalRealhardwoodveneeraccordiongatepanels_____________________Choosefromsamplekit.
Allaccordiongatesexceptwhitehavebronzehardware.White gates have aluminum hardware.
2.07 Optional Features:
•Insetpanelcarwithmatchingceiling
•Raisedpanelcarwithmatchingceiling
•4recessedLEDlightswithblacktrimrings
•Factoryfinishedcarwallpanels_________________Stain#_________________Finish
•COPwithintegratedphonebox
•Customwoodinteriors
•Customfactoryfinishes(antiqued,distressed,&crackle)
•Greenmaterialalternativesandfinishesforcarinteriors
•Scissorgate
•Hardwoodveneeraccordiongate
•Clearpanelaccordiongate_______Allpanels________3centerpanels
•Autogateoperator(availableforusewithaccordiongateonly)
24
Section 14205 - Bid SpecificationsResidential Elevator - 1:2 Roped Hydraulic
SymmetryElevator.com | 877-375-1428
•3/4”finishedorunfinishedfactoryinstalledhardwoodcarflooring
•Factoryflooringinsertfor1/4”flooringbyothers
•Buffersprings(requiresminimumof10”pitdepth)
•Upperandlowerfinallimits,inadditiontoNormalupanddownlimits
•KeyswitchforCOPandhallstations
•750#carcapacity
3.01 Work By Others:Theinstallationoftheelevatorandits’hardwareistheresponsibilityoftheElevatorContractor.Theinstallationandpreparationofa suitable hoistway, main power, door installation, pit construction and structural support are Work by Others
A. Hoistway shall be constructed from dimensional lumber, concrete or concrete block to support loads listed in the shop drawings with elevator rail reaction and pit loading consideration by others. The hoistway must be plumb and square within 1/4”toptobottomandsidetoside.
B.Allstructuralmemberlocationsinthehoistwaywallsareperthemanufacturer’sshopdrawings.
C.DoorcenterlinesarelistedontheshopdrawingsandareNOTtheCenterofthehoistway.
D.Mainpowerfromthemainbreakerpaneltotheelevatorlocationshownintheshopdrawingsis“byothers”.Equipment disconnects are included with the controller.
E.Installationofalivephonelineandoutlettotheelevatorlocation,asshownontheshopdrawings,iswork“byothers”.
F.MachineSpaceofapprox.4’x5’(orasrequiredbylocalAHJ)shallbeprovidedonalowerfloortocontainthecontrollerand pump unit. The requirements for this room will be shown on the shop drawings and coordinated with the various trades priortofabrication.(Seeshopdrawingsforlayout)
G.CompactmachinespacesasallowedbylocalAHJtopconformwithmanufacturerslayout.(Seeshopdrawingsfor layout)
H. Pre-wire in the walls shall be coordinated with the builder prior to wall construction and drywall installation.
End of Section
25
Section 14205 - Bid SpecificationsResidential Elevator - 1:2 Roped Hydraulic
SymmetryElevator.com | 877-375-1428
AtSymmetryweareseriousaboutSAFETY!That’swhywe use only the best. The Relialign series by Honeywell, electromechanical door interlock holds the door in place and prevents it from being opened when not desired. A number of design features contribute to its enhanced safety, reduction of nuisance stoppages and call-backs, as well as simplified wiring and installation. A Honeywell MICRO SWITCH is used to indicate door closure, providing an extra level of reliability.
Reliability and smooth operations are also enhanced by use of a metal latch that is less susceptible to bending and breakage than plastic. The lack of open or exposed contactsminimizesthepossibilityofownersmakingmanualadjustments.Finally,theengagementofthelatchinitiates electrical contact.
Thesnapactioncammechanismrequireslessadjustmentsetup time and reduces door movement that could lead to a nuisance shutdown. Connection options include a 6-pinterminalstriporaCat5-pinconnector,simplifyinginstallation. The Relialign Series is designed to work seamlessly with your Symmetry elevator.
ComplianttoASMEA17.1Standard104,andCSA-B44.1
Standard Features• Manualoverrideforeasyactivationwithoutuserhazard• Twowayseparatemechanicalactionstoindicatedoor closure • Ruggedplasticmoldedhousing• Metallatch,latchengagementminimizesnuisancestoppage• Internalsolenoidcontrol• Noopenorexposedcontacts • Doorclosureretentioncamtoholddoorwithminimallatch- to-interlock play• Seriesorparallelwiringoptionforthedoorclosedanddoor locked switches• 6-pinterminalstriporCat5-pinconnectionoptions• Configurableproductplatform • UniversalvoltageforACandDCapplications
Design Features
• Thermoplasticcoveroffersdurabilityaswellasaesthetically appealingdesign(fixturematchingcoversavailable)• MICROSWITCHusedtoindicatedoorlockedwhenlatch rotates cam• MICROSWITCHusedtomonitordoorclosure,newdesign location harder to tamper or defeat• CustomsolenoiddesignsoffersuniversalvoltageforACor DC• Newentryforwiringonbacksideofinterlockhelpskeep wiring neat and out of sight • Manualoverridefeatureasrequiredbycertainapproval agencies • MICROSWITCHcontrollingsolenoid,reducespower consumption and complexity of host controller• Honeywell’sreliablecamdesignprovidespositivesnap action, new material provides more pull force • Stainlesssteellatchengagementholdsthedoorsecurely closedtominimizealignmentissues/nuisancestoppages
26
SECURE LOCK II
SymmetryElevator.com | 877-375-1428 27
Contractor Site Notes
Hoistway Layout Notes