Portable Syngas Monitoring SystemPortable Syngas Analyser The Portable Syngas Monitoring System (SMS-P) is an anaylser that utilises non-dispersive IR and other techniques to provide the measurement of CO, CO2, CH4, H2 & O2
The SMS-P provides a measurement of all the major constituents of the syngas
and calculates the live CV value, essential to determine your qualification for
renewable obligation certificates (ROCS). In modern gasification where syngas
composition is paramount for determining the calorific value, the a1-cbiss
SMS- P provides an accurate, cost-effective solution.
The SMS-P is powered by Li-on battery to provide on the spot
measurement of syngas monitoring in pyrolysis and gasification
processes
Small, Robust & Lightweight Designed to be used in conjunction with the a1-cbiss portable
sampling probe, which features a selection of sampling tubes for
varied process conditions.
Internal Data Logger for Real-Time Data Readings Equipped with an internal data logger, the SMS can easily connect to a
laptop (via a RS232 cable) to provide real time data and data
storage on a laptop
KEYBENEFITS• Uses an internal Li-on battery to work
without an AC power supply
• Temperature regulated enclosure for NDIR
and TCD detectors
• Equipped with an internal sampling
pump
• Lightweight, moulded casing and
shoulder strap for increased portability &
ease of transportation
• Internal data logger connects to PC /
laptop to display real time data
The SMS-P quickly measures syngas constituents and aids in achieving ROCs accreditation
“ “
GASESANALYSED
CO H2CO2 CnHmCH4
Cert No. 996ISO 9001
11 Ark Royal Way, Lairdside Technology Park, Tranmere, Wirral, CH41 9HTT: +44(0)151 666 8300 F: +44(0)151 666 8329 E: [email protected] W: www.a1-cbiss.com Buy Online: shop.a1-cbiss.com
TECHNICALSPECIFICATION
GENERAL• Set up time <15 minutes
• Highly visible yellow casing
MEASUREMENT TECHNOLOGY • CO, CO2, CH4, CnHm: proprietary dual beam NDIR detectors
• O2: industrial electrochemical cell
• H2: proprietary thermal conductivity detector
MEASUREMENT RANGES • CO: 0-100%
• CO2: 0-50%
• CH4 : 0-10%
• CnHm : 0-10%
• O2: 0-25%
• H2: 0-50%
• H2: 0-50%
• Additional ranges available at no extra cost
CALCULATION • BTU index (gas calorific value)
• High Heating Value or Low Heating Value (in MJ/m3 or
kcal/m3)
• Optional N2
OPERATING TEMP & PRESSURE • Tamb: 0-50°C
• Pamb: 86 to 108 kPa
• RH: 0-95% non condensing
PERFORMANCE • Resolution: 0,01%
• Accuracy: ≤ ± 2% FS
• Repeatability: ≤ 2%
• Zero: Auto-zeroing function via keyboard interface
• Response time: (T90) ≤ 15 sec
• Warm-up time: 800 seconds (auto-zeroing cycle during
the last 120 seconds)
DATA LOGGING • Up to 1500 sets of data
• Logging rate adjustable from 3 to 99 sec
• Identify 10 different sites and up to 100 measuring points
• Simultaneous indication of the 7 measures and units
POWER • Power supply: External 220 VAC-50Hz
• Internal with battery and charger; Autonomy of > 4h with
pump in operation
• Electrical connection: Cold appliance plug with 1.5 m of
cable
PHYSICAL • Dimensions: L 380 × D140 × H255 mm
• Weight: Approx. ± 5 kg (7 kg max with packaging)
• Casing: Robust aluminium casing
STANDARD CONFIGURATIONS • HV = Heating Value
GAS 3160 HV: CO, CO2, CH4, H2, O2, CnHm, HV
GAS 3150 HV: CO, CO2, CH4, H2, O2, HV
GAS 3140 HV: CO, CO2, CH4, H2, HV