ONLINE DATA SHEETwww.mysick.comUltrasonic sensorsUC12UC12-11231Ultrasonic sensorsAAAAAAAAAAAAAA SICK AG. Subject to change without notice.AAAAAAAAAAAAAA8/27/2013 10:27:03 AM Ultrasonic sensors UC12

1) 2) Referring to current measurement value Model Name > UC12-11231Part No. > 6029831At a glanceObject detection independent of material color and ambient light - eventransparent foils, glass, liquids and bottles are reliably detectedFast and easy teach-in with single push-button Immune to dirt, dust and fog Two ambivalent switching outputs (Q, /Q) Excellent background suppression Three operation modes: Distance to Object (DtO), Window (Wnd) or Objectbetween sensor and background (OBSB)Your benefitsFast commissioning due to single-button teach-in Full mechanical compatibility to photoelectric sensors increase applicationflexibility without machine modificationStandard proximity, window and reflection modes provide application flexibility,which increases reliability and productivityIntegrated temperature compensation ensures high measurement accuracy Complementary switching outputs immediately signal broken wiring, reducingfaulty production results PerformanceWorking range, limiting range: 20 mm ... 150 mm, 250 mmRepeatability 1): 0.15 %Accuracy 2): 1 %Response time: 30 msOutput rate: 8 msSwitching frequency: 25 HzUltrasonic frequency (typical): 380 kHzDetection area (typical): See diagramsTemperature compensation: Additional function: Set switching mode: Distance to object (DtO) Window (Wnd) Objectbetween sensor and background (ObSB)Teach-in of switching outputTemperature compensationReset to factory defaultLock user interfaceUltrasonic sensorsAAAAAAAAAAAAAA SICK AG. Subject to change without notice.AAAAAAAAAAAAAA8/27/2013 10:27:03 AM

1) Output Q short-circuit protected2) Complementary switching outputs (Q, /Q)3) PNP: HIGH = VS - (< 2 V) LOW = 0 V

1) Limit values, reverse-polarity protected, operation in short-circuit protected network, max. 8 A2) Without load3) Ultrasonic transducer: polyurethane foam, glassepoxy resin

InterfacesOutput type 1): 2): 3): 2 x PNP (500 mA)Hysteresis: 2 mmMechanics/electronicsSending axis: StraightSupply voltage Vs 1): DC 10 V ... 30 VPower consumption 2): 1.2 WInitialization time: < 300 msHousing material 3): Zinc diecastConnection type: Connector M12, 4-pinIndication: Dual LEDWeight: 75 gAmbient dataEnclosure rating: IP 67Protection class: IIIAmbient temperature: Operation: -25 ... 70 CStorage: -40 ... 85 CUltrasonic sensorsAAAAAAAAAAAAAA SICK AG. Subject to change without notice.AAAAAAAAAAAAAA8/27/2013 10:27:03 AM Dimensional drawingAdjustmentsUltrasonic sensorsAAAAAAAAAAAAAA SICK AG. Subject to change without notice.AAAAAAAAAAAAAA8/27/2013 10:27:03 AM Connection typeConnection diagramUltrasonic sensorsAAAAAAAAAAAAAA SICK AG. Subject to change without notice.AAAAAAAAAAAAAA8/27/2013 10:27:03 AM Characteristic curveSICK AG|Waldkirch|Germany|www.sick.com USmod 4c int40AustraliaPhone+61 3 9457 06001800 334 802 [email protected]/LuxembourgPhone+32 (0)2 466 55 [email protected]+55 11 [email protected]+1 905 771 14 [email protected] RepublikaPhone+420 2 57 91 18 [email protected] +86 4000 121 [email protected] +852-2153 [email protected]+45 45 82 64 [email protected]+49 211 [email protected]+34 93 480 31 [email protected]+33 1 64 62 35 [email protected] BritainPhone+44 (0)1727 [email protected]+91224033 8333E-Mail [email protected][email protected]+39 02 27 43 [email protected]+81 (0)3 3358 [email protected]+36 1 371 [email protected]+31 (0)30 229 25 [email protected] Phone+47 67 81 50 [email protected]+43 (0)22 36 62 28 [email protected]+48 22 837 40 [email protected]+40 356 171 120 [email protected][email protected]+41 41 619 29 [email protected]+65 6744 [email protected]+386 (0)1-47 69 [email protected] AfricaPhone+27 11 472 3733E-Mail [email protected] KoreaPhone+82 2 786 6321/[email protected]+358-9-25 15 [email protected]+46 10 110 10 [email protected][email protected]+90 (216) 528 50 [email protected] Arab EmiratesPhone+971 (0) 4 8865 [email protected]/MxicoPhone+1(952) 941-67801 800-325-7425 [email protected] representatives and agencies at www.sick.com