8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
1/553
Product Manual
3HAC 7677-1
IRB 6400R
M2000/Rev. 2
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
2/553
The information in this document is subject to change without notice and should not be construed as acommitment by ABB Automation Technology Products AB, Robotics. ABB Automation TechnologyProducts AB, Robotics assumes no responsibility for any errors that may appear in this document.
In no event shall ABB Automation Technology Products AB, Robotics be liable for incidental orconsequential damages arising from use of this document or of the software and hardware describedin this document.
This document and parts thereof must not be reproduced or copied without ABB AutomationTechnology Products AB, Roboticss written permission, and contents thereof must not be imparted toa third party nor be used for any unauthorized purpose. Contravention will be prosecuted.
Additional copies of this document may be obtained from ABB Automation Technology Products AB,Robotics at its then current charge.
ABB Automation Technology Products AB
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
3/553
1 Introduction / System Description
2 Product Specifications
3 Safety
4 Certificates
5 Configuration List
6 Decomissioning
7 Description
8 Installation and Comissioning
9 Maintenace and Repairs
10 Fault Tracing Guide
11 Spare Parts List
12 Circuit Diagram
13 Installation and Comissioning
14 Maintenance
C
ommonCha
pters3HAC 7677-1
M2000/Rev. 2
oductManu
alIRB
6400R
C
ontroller
lator
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
4/553
Introduction
CONTENTSPage
1 Introduction ....................................................................................................... 3
1.1 How to use this Manual ............................................................................. 3
1.2 What you must know before you use the Robot........................................ 3
1.3 Identification .............................................................................................. 4
1.4 Structure Manipulator ................................................................................ 6
1.5 Structure Controller ................................................................................... 111.6 Electronics unit .......................................................................................... 11
1.6.1 The computer system consists of the following parts: ..................... 12
http://intro-e.pdf/http://intro-e.pdf/http://intro-e.pdf/http://intro-e.pdf/http://intro-e.pdf/http://intro-e.pdf/http://intro-e.pdf/http://intro-e.pdf/http://intro-e.pdf/http://intro-e.pdf/http://intro-e.pdf/http://intro-e.pdf/http://intro-e.pdf/http://intro-e.pdf/http://intro-e.pdf/http://intro-e.pdf/8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
5/553
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
6/553
This manual provides information on installation, preventive maintenance,troubleshooting, and how to carry out repairs on the manipulator and controller.Its intended audience is trained maintenance personnel with expertise in bothmechanical and electrical systems. The manual does not in any way assume to
take the place of the maintenance training course offered by ABB FlexibleAutomation.
Anyone reading this manual should also have access to the Users Guide.
The chapter entitled System Description provides general information on therobot structure, such as its computer system, input and output signals, etc.
How to assemble the robot and install all signals, etc., is described in the chapteron Installation and Commissioning.
If an error should occur in the robot system, you can find out why it hashappened in the chapter on Troubleshooting. If you receive an error message,you can also consult the chapter on System and Error Messages in the UsersGuide. It is very helpful to have a copy of the circuit diagram at hand whentrying to locate cabling faults.
Servicing and maintenance routines are described in the chapter onMaintenance.
Usually requires only standard tools. Some repairs, however, require specifictools. These repairs and the type of tool required, are described in more detail inthe chapter Repairs.
Must always be switched off whenever work is carried out in the controllercabinet. Note that even though the power is switched off, the orange-colouredcables may be live. The reason for this is that these cables are connected to
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
7/553
Identification plates indicating the type of robot and serial number, etc., are located onthe manipulator (see Figure 1) and on the front of the controller (see Figure 2).
Note! The identification plates and label shown in the figures below, only serve asexamples. For exact identification see the plates on the robot in question.
Identification plate showithe IRB 6400R / M2000
Made in SwedenS-721 68 Vsters Sweden
IRB 6400R M2000
IRB 6400R/2.5-150
XXXXXX
See instructions
2000-XX-XX
2,8-150 : 2240 kg
2,8-200 : 2390 kg
3.0-100 : 2250 kg
Type:
Robot version:
Man. order:
Nom. load
Serial. No:
Date of manufacturing:
Net weight
2,5.120 : 2060 kg
2.5-150 : 2060 kg
2,5-200 : 2230 kg
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
8/553
.
Made in SwedenS-721 68 Vsters Sweden
ABB Robotics Products AB
Type:
Robot version:
Voltage: 3 x 400 V
Power:
Man. order:
Re.No:
Serial. No:
Date of manufacturing:
Net weight:
IRB 6400R M2000
IRB 6400R/2.5-150
Frequency: 50-60 Hz
7.2 kVA
XXXXXX
RXXXXXXXXXX
64-XXXXX
2000-XX-XX
240 kg
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
9/553
The robot is made up of two main parts, the manipulator and controller. Thecontroller is described in section 1.5.
The Manipulator is equipped with maintenance-free AC motors, which haveelectromechanical brakes. The brakes lock the motors when the robot is inoperativefor more than 1000 hours. The time can be configured by the user.
The following figures show the various ways in which the different manipulatorsmove and their component parts.
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
10/553
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
11/553
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
12/553
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
13/553
.
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
14/553
The controller, which contains the electronics used to control the manipulator andperipheral equipment, is specifically designed for robot control and consequentlyprovides optimal performance and functionality.
Figure 11shows the location of the various components on the cabinet.
All control and supervisory electronics, apart from the serial measurement board thatis located inside the manipulator, are gathered together inside the controller.
Manipulatorconnection
Mains switch
Teach pendant
Operators panel
Service outlet
ComputerSystem
er u
pp
lyDC
Link
Driveun
it3
Driveun
it2
Driveun
it1
alboard
1-5
mpu
ter
ompu
ter
mpu
ter
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
15/553
One Main computer slot and 7 PCI slots.
Controls the entire robot system. Intel PentiumTM
- CPU. 32 MB DRAM. 10/100 Mb, 7/s Ethernet controller.
64 Mb Flash disk, (Optional 128 Mb).
Control of the manipulator motors.
Handles I/O communication (CAN, Ethernet, serial links).
Handles external axis and I/O computers, field bus communication, etc.
Four regulated and short-circuit-protected output voltages (12V, 5V, 3.3V).24V DC Input.
Rechargeable NiCd battery and battery management card.
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
16/553
230V AC supply, distributes DC power to computer system.
Gathers and coordinates all signals that affect operational and personal safety.
Enables communication with external equipment by means of digital inputs andoutputs, analog signals, or field buses.
I/O units can alternatively be located outside the cabinet. Communication with robotdata is implemented via a stranded wire CAN bus which allows the units to be
I/O units (x4)
AC connection
Motors On and brake contactors Floppy disk (Opt.)
Connector
Panel unit
Computer System
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
17/553
- Axis computer Drive and Measurement System.
- I/O computer Serial ports, CAN bus, Safety system, TPU.
- Extra axis computer D and M Sys.
- Extra I/O computer Serial parts, CAN bus.
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
18/553
Safety
Contents page
1 Safety 1
1.1 General............................................................................................ 1
1.1.1 Introduction .......................................................................... 1
1.2 Applicable Safety Standards ........................................................... 1
1.3 Fire-Extinguishing............................................................................ 1
1.4 Definitions of Safety Functions........................................................ 2
1.5 Safe Working Procedures ............................................................... 2
1.5.1 Normal operations ............................................................... 2
1.6 Programming, Testing and Servicing............................................... 3
1.7 Safety Functions.............................................................................. 3
1.7.1 The safety control chain of operation................................... 3
1.7.2 Emergency stops ................................................................. 4
1.7.3 Mode selection using the operating mode selector.............. 4
1.7.4 Programming and testing at reduced speed........................ 5
1.7.5 Testing at full speed ............................................................. 5
1.7.6 Automatic operation............................................................. 5
1.7.7 Enabling device ................................................................... 6
1.7.8 Hold-to-run control ............................................................... 61.7.9 General Mode Safeguarded Stop (GS) connection ............. 6
1.7.10 Automatic Mode Safeguarded Stop (AS) connection .......... 7
1.7.11 Limiting the working space................................................... 7
1.7.12 Supplementary functions ..................................................... 7
1.8 Safety Risks Related to End Effectors ............................................ 8
1.8.1 Gripper................................................................................. 81.8.2 Tools/workpieces ................................................................. 8
1.8.3 Pneumatic/hydraulic systems .............................................. 8
1.9 Risks during Operational Disturbances........................................... 8
1 10 Ri k d i I t ll ti d S i 8
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
19/553
Safety Contents
page
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
20/553
Safety
1 Safety
1.1 General
This information on safety covers functions that have to do with the operation of theindustrial robot.
The information does not cover how to design, install and operate a complete system,nor does it cover all peripheral equipment, which can influence the safety of the totalsystem.
To protect personnel, the complete system must be designed and installed inaccordance with the safety requirements set forth in the standards and regulations ofthe country where the robot is installed.
The users of ABB industrial robots are responsible for ensuring that the applicablesafety laws and regulations in the country concerned are observed and that the safetydevices necessary to protect people working with the robot system have been designed
and installed correctly.People who work with robots must be familiar with the operation and handling of theindustrial robot, described in the applicable documents, e.g. Userss Guide andProduct Manual.
The diskettes which contain the robots control programs must not be changed inany way because this could lead to the deactivation of safety functions, such asreduced speed.
1.1.1 Introduction
Apart from the built-in safety functions, the robot is also supplied with an interface forthe connection of external safety devices.
Via this interface, an external safety function can interact with other machines andperipheral equipment. This means that control signals can act on safety signalsreceived from the peripheral equipment as well as from the robot.
In the Product Manual -Installation and Commissioning,instructions are provided forconnecting safety devices between the robot and the peripheral equipment.
1.2 Applicable Safety Standards
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
21/553
Safety Safety
1.4 Definitions of Safety Functions
Emergency stop IEC 60204-1, 10.7
A condition which overrides all other robot controls, removes drive power from robotaxis actuators, stops all moving parts and removes power from other dangerousfunctions controlled by the robot.
Enabling device ISO 11161, 3.4
A manually operated device which, when continuously activated in one position only,allows hazardous functions but does not initiate them. In any other position, hazardousfunctions can be stopped safely.
Safety stop ISO 10218 (EN 775), 6.4.3
When a safety stop circuit is provided, each robot must be delivered with thenecessary connections for the safeguards and interlocks associated with this circuit. Itis necessary to reset the power to the machine actuators before any robot motion can
be initiated. However, if only the power to the machine actuators is reset, this shouldnot suffice to initiate any operation.
Reduced speed ISO 10218 (EN 775), 3.2.17
A single, selectable velocity provided by the robot supplier which automaticallyrestricts the robot velocity to that specified in order to allow sufficient time for peopleeither to withdraw from the hazardous area or to stop the robot.
Interlock (for safeguarding) ISO 10218 (EN 775), 3.2.8
A function that interconnects a guard(s) or a device(s) and the robot controller and/orpower system of the robot and its associated equipment.
Hold-to-run control ISO 10218 (EN 775), 3.2.7
A control which only allows movements during its manual actuation and which causesthese movements to stop as soon as it is released.
1.5 Safe Working Procedures
Safe working procedures must be used to prevent injury. No safety device or circuitmay be modified, bypassed or changed in any way, at any time.
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
22/553
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
23/553
Safety Safety
If any contact in the safety chain of operation opens, the robot always reverts to theMOTORS OFF mode. The MOTORS OFF mode means that drive power is removed
from the robots motors and the brakes are applied.
Figure 1 Safety control chain of operation
The status of the switches is indicated by LEDs on top of the panel unit in the controlcabinet and is also displayed on the Teach Pendant Unit (I/O window).
After a stop, the switch must be reset at the unit which caused the stop, before therobot can be ordered to start again.
The safety chains must never be bypassed, modified, or changed in any other way.
1.7.2 Emergency stops
An emergency stop should be activated if there is a danger to people or equipment.Built-in emergency stop buttons are located on the operators panel of the robot
controller and on the Teach Pendant Unit.External emergency stop devices (buttons, etc.) can be connected to the safety chainby the user (see Product Manual -Installation and Commissioning). They must beconnected in accordance with the applicable standards for emergency stop circuits.
Before commissioning the robot, all emergency stop buttons or other safety equipmentmust be checked by the user to ensure their proper operation
&
&
Interlocking
ENRUN
Drive
Unit M
K1 K2
LIM1 LIM2 ES2ES1
GS1 GS2 AS2AS1
TPU
En1
TPU
En2
Man2Man1
Auto1 Auto2
K1 K2
+ +
Externalcontactors
S f
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
24/553
Safety Safety
One automatic and two manual modes are available:
The manual mode, < 250 mm/s or 100%, must be selected whenever anyone enters therobots safeguarded space. The robot must be operated using the Teach Pendant Unitand, if 100% is selected, using Hold-to-run control.
In automatic mode, the operating mode selector is switched to , and all safetyarrangements, such as doors, gates, light curtains, light beams and sensitive mats, etc.,are active. Nobody may enter the robots safeguarded space. All controls, such asemergency stops, the control panel and control cabinet, must be easily accessible fromoutside the safeguarded space.
1.7.4 Programming and testing at reduced speed
Robot movements at reduced speed can be carried out as follows:
1. Set the operating mode selector to
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
25/553
Safety Safety
1.7.7 Enabling device
When the operating mode selector is in the MANUAL or MANUAL FULL SPEEDposition, the robot can be set to the MOTORS ON mode by depressing the enablingdevice on the Teach Pendant Unit.
Should the robot revert to the MOTORS OFF mode for any reason while the enablingdevice is depressed, the latter must be released before the robot can be returned to theMOTORS ON mode again. This is a safety function designed to prevent the enablingdevice from being rendered inactive.
When the enabling device is released, the drive power to the motors is switched off,the brakes are applied and the robot reverts to the MOTORS OFF mode.
If the enabling device is reactivated, the robot changes to the MOTORS ON mode.
1.7.8 Hold-to-run control
This function is always active when the operating mode selector is in the MANUAL
FULL SPEED position. It is possible to set a parameter to make this function activealso when the operating mode selector is in the MANUAL position.
When the Hold-to-run control is active, the enabling device and the Hold-to-runbutton on the Teach Pendant Unit (TPU) must be depressed in order to execute aprogram. When the button is released, the axis (axes) movements stop and the robotremains in the MOTORS ON mode.
Here is a detailed description of how to execute a program in Hold-to-run control:
1. Activate the enabling device on the TPU.
2. Choose execution mode using the function keys on the TPU:
- Start(continuous running of the program)
- FWD(one instruction forwards)
- BWD(one instruction backwards)
3. Wait for the Hold-to-run alert box.
4. Activate the Hold-to-run button on the TPU.Now the program will run (with the chosen execution mode) as long as the Hold-to-run button is pressed. Releasing the button stops program execution and activating thebutton will start program execution again.
For FWD and BWD execution modes, the next instruction is run by releasing and
Safety
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
26/553
Safety Safety
curtains, light beams or sensitive mats. The GS is active regardless of the position ofthe operating mode selector.
When this connection is open the robot changes to the MOTORS OFF mode. To resetto MOTORS ON mode, the device that initiated the safety stop must be interlocked inaccordance with applicable safety regulations. This is not normally done by resettingthe device itself.
1.7.10 Automatic Mode Safeguarded Stop (AS) connection
The AS connection is provided for interlocking external safety devices, such as lightcurtains, light beams or sensitive mats used externally by the system builder. The ASis especially intended for use in automatic mode, during normal program execution.
The AS is bypassed when the operating mode selector is in the MANUAL orMANUAL FULL SPEED position.
1.7.11 Limiting the working space
Note! Not valid for IRB 340(r) and IRB 140
For certain applications, movement about the robots main axes must be limited inorder to create a sufficiently large safety zone. This will reduce the risk of damage tothe robot if it collides with external safety arrangements, such as barriers, etc.
Movement about axes 1, 2 and 3 can be limited with adjustable mechanical stops or bymeans of electrical limit switches. If the working space is limited by means of stops or
switches, the corresponding software limitation parameters must also be changed. Ifnecessary, movement of the three wrist axes can also be limited by the computersoftware. Limitation of movement of the axes must be carried out by the user.
1.7.12 Supplementary functions
Functions via specific digital inputs:
- A stop can be activated via a connection with a digital input. Digital inputscan be used to stop programs if, for example, a fault occurs in the peripheralequipment.
Functions via specific digital outputs:
E i di f l i h b
Safety S f t
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
27/553
Safety Safety
1.8 Safety Risks Related to End Effectors
1.8.1 Gripper
If a gripper is used to hold a workpiece, inadvertent loosening of the workpiece mustbe prevented.
1.8.2 Tools/workpiecesIt must be possible to turn off tools, such as milling cutters, etc., safely. Make sure thatguards remain closed until the cutters stop rotating.
Grippers must be designed so that they retain workpieces in the event of a powerfailure or a disturbance of the controller. It should be possible to release parts bymanual operation (valves).
1.8.3 Pneumatic/hydraulic systems
Special safety regulations apply to pneumatic and hydraulic systems.
Residual energy may be present in these systems so, after shutdown, particular caremust be taken.
The pressure in pneumatic and hydraulic systems must be released before starting torepair them. Gravity may cause any parts or objects held by these systems to drop.Dump valves should be used in case of emergency. Shot bolts should be used toprevent tools, etc., from falling due to gravity.
1.9 Risks during Operational Disturbances
If the working process is interrupted, extra care must be taken due to risks other thanthose associated with regular operation. Such an interruption may have to be rectifiedmanually.
Remedial action must only ever be carried out by trained personnel who are familiarwith the entire installation as well as the special risks associated with its differentparts.
The industrial robot is a flexible tool which can be used in many different industrialapplications All work must be carried out professionally and in accordance with
Safety Safety
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
28/553
Safety Safety
Note! To prevent injuries and damage during the installation of the robot system, theregulations applicable in the country concerned and the instructions of ABB
Robotics must be complied with.Special attention must be paid to the following points:
- The supplier of the complete system must ensure that all circuits used in thesafety function are interlocked in accordance with the applicable standardsfor that function.
- The instructions in the Product Manual -Installation and Commissioningmust always be followed.
- The mains supply to the robot must be connected in such a way that it can beturned off outside the robots working space.
- The supplier of the complete system must ensure that all circuits used in theemergency stop function are interlocked in a safe manner, in accordance withthe applicable standards for the emergency stop function.
- Emergency stop buttons must be positioned in easily accessible places so that
the robot can be stopped quickly.- Safety zones, which have to be crossed before admittance, must be set up in
front of the robots working space. Light beams or sensitive mats are suitabledevices.
- Turntables or the like should be used to keep the operator away from therobots working space.
- Those in charge of operations must make sure that safety instructions are
available for the installation in question.
- Those who install the robot must have the appropriate training for the robotsystem in question and in any safety matters associated with it.
Although troubleshooting may, on occasion, have to be carried out while the powersupply is turned on, the robot must be turned off (by setting the mains switch to OFF)when repairing faults, disconnecting electric leads and disconnecting or connectingunits.
Even if the power supply for the robot is turned off, you can still injure yourself.
- The axes are affected by the force of gravity when the brakes are released. Inaddition to the risk of being hit by moving robot parts, you run the risk ofbeing crushed by the tie rod.
Safety Safety
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
29/553
Safety Safety
1.11 Dimensioning the safety fence
A safety fence must be fitted around the robot to ensure a safe robot installation. Thefence must be dimensioned to withstand the force created if the load being handled bythe robot is dropped or released at maximum speed. The maximum speed is determinedfrom the maximum velocities of the robot axes and from the position at which the robotis working in the workcell (see Product Specification -Description, Robot Motion).
Applicable standards are ISO/DIS 11161 and prEN 999:1995.
1.12 Standards of interest when the robot is part of a cell
1.13 Risks Associated with Live Electric Parts
1.13.1 Controller
A danger of high voltage is associated with the following parts:
- The mains supply/mains switch- The power unit
- The power supply unit for the computer system (55VAC)
- The rectifier unit (260VAC and 370V DC. NB: Capacitors!)
EN 294 Safety of machinery - Safety distance to prevent danger zones being reached bythe upper limbs.
EN 349 Safety of machinery - Minimum gaps to avoid crushing of parts of the humanbody.
EN 811 Safety of machinery - Safety distance to prevent danger zones being reached bythe lower limbs.
Pr EN 999 Safety of machinery - The positioning of protective equipment in respect ofapproach speeds of the human body.
EN 1088 Safety of machinery - Inter locking device associated with guards principles fordesign and selection.
Table 1 Standards of interest when the robot is part of a cell
Safety Safety
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
30/553
Safety Safety
1.13.2 Manipulator
A danger of high voltage is associated with the manipulator in:
- The power supply for the motors (up to 370V DC)
- The user connections for tools or other parts of the installation (max.230VAC, see Product Manual -Installation and Commissioning)
1.13.3 Tools, material handling devices, etc.
Tools, material handling devices, etc., may be live even if the robot system is in theOFF position. Power supply cables which are in motion during the working processmay be damaged.
1.14 Emergency Release of Mechanical Arm
If an emergency situation occurs where a person is trapped by the mechanical robotarm, the brake release buttons should be pressed whereby the arms can be moved torelease the person. To move the arms by manpower is normally possible on thesmaller robots (1400 and 2400), but for the bigger ones it may not be possible withouta mechanical lifting device such as an overhead crane.
If power is not available the brakes are applied and therefore manpower may not besufficient for any robot.
Before releasing the brakes, be sure that the weight of the arms does not enhancethe pressure on the trapped person.
1.15 Limitation of Liability
The above information regarding safety must not be construed as a warranty byABB Robotics that the industrial robot will not cause injury or damage even if all
safety instructions have been complied with.
1.16 Related Information
D ib d i
Safety Safety
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
31/553
Safety Safety
To the User
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
32/553
Wereserveallrightsinthis
documentandinthe
informationcontainedthere
in.
Reproduction,useor
disclosuretothirdpartiesw
ithoutexpressauthorityis
strictlyforbidden.A
BBR
oboticsProductsAB
Declaration by the manufacturer
as defined by machinery directive 89/392/EEC Annex II B
Herewith we declare that the industrial robot
IRB 140 IRB 340 IRB 640 IRB 1400 IRB 2400 IRB 4400
IRB 6400S IRB 6400PE IRB 6400R IRB 840
manufactured by ABB Robotics Products AB 721 68 Vsters, Sweden
with serial No.
Label withserial number
is intended to be incorporated into machinery or assembled with other machinery to constitute
machinery covered by this directive and must not be put into service until the machinery into
which it is to be incorporated has been declared in conformity with the provisions of the
directive, 91/368 EEC.
Applied harmonised standards in particular:
EN 292-1 Safety of machinery, basic terminology
EN 292-2 Safety of machinery, technical principles/specifications, emergency stop
EN 418 Safety of machinery, emergency stop equipment
EN 563 Safety of machinery, temperatures of surfaces
EN 614-1 Safety of machiney, ergonomic design principles
EN 775 Robot safety
EN 60204 Electrical equipment for industrial machines 1)
prEN 574 Safety of machinery, two-hand control device
prEN 953 Safety of machinery, fixed / moveable guards
prEN 954-1 Safety of machinery, safety related parts of the control system
EN 50081-2 EMC, Generic emission standard. Part 2: Industrial environment
EN 55011 Class A Radiated emission enclosure
EN 55011 Class A Conducted emission AC Mains
EN 50082-2 EMC, Generic immunity standard. Part 2: Industrial environmentEN 61000-4-2 Electrostatic discharge immunity test
EN 61000-4-3 Radiated, radio-frequency, electromagnetic field immunity yest
ENV 50204 Radeated electromagnetic field from digital radio telephones, immunity test
EN 61000-4-4 Electrical fast transient/burst immunity test
ENV 50141 Conducted disturbences induced by radio-frequency fields, immunity test
To the UserDeclaration by the manufacturer.This is only a translation of the customs declaration. The originaldocument (in English) with the serial number on it is suppliedtogether with the robot
ORINFOR
MATION
ABB ROBOTICS PRODUCTS AB CONFIGURATION LIST
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
33/553
ABB ROBOTICS PRODUCTS AB CONFIGURATION LIST
Robot type: Revision: Manufact order no: Serial no:
For RAC: RAC Ref no: Sales order no:
Tested and approved: Date Name
MANIPULATOR:
CONTROL SYSTEM:
ROBOT SYSTEM:
DateDelivery from factory:
Delivery to customer:
Acceptance by customer:
Customer information:
Customer:
Address:
OPTIONS/DOCUMENTATION
QTY OPTION/PARTNO REVISION DESCRIPTION
To the User
The Configuration List is an individual specification of the robotsystem delivered regarding configuration and extent.
On delivery, the complete document is placed in the robot controller.
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
34/553
page
General ................................................................................................... 1
Manipulators ................................................................................... 1
Controller ........................................................................................ 1
Scrapping................................................................................................. 2
General warning ............................................................................. 2
Oil and grease ................................................................................ 2
Parts requiring special treatment when scrapping ......................... 2
IRB 140, 1400, 2400 and 4400: Motors ......................................... 2
IRB 4400: Balancing cylinder ......................................................... 3
IRB 6000/6400/6400R and IRB 640: Balancing cylinder ................ 3
Scrapping Balancing cylinders ....................................................... 4
http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
35/553
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
36/553
The components of the robot are manufactured from many different materials. Someof them are listed below to facilitate scrapping, i.e. so that the components can bedisposed of in a way that does not have a detrimental effect on anyones health or theenvironment.
Lead Counter-weight IRB 6400
Batteries,NiCad or Lithium
Serial measurement board All robot types
Copper Cables, motors All robot types
Cast iron/nodular iron Base, lower arm, upper arm, parallel bar/arm
All robot types
Steel Gears, screws, base-frame, etc. All robot types
Samarium-Cobalt Brakes, motors IRB 1400, 2400, 4400
Neodymium Brakes, motors IRB 6400, 640
Plastic/rubber (PVC) Cables, connectors, drive belts, etc. All robot types
Oil, grease Gearboxes All robot types
Aluminium Covers, sync. brackets All robot types
Castings in wrist, upper arm tubular IRB 1400, 2400
Copper Transformers, cables
Tin Cables
Alu-Zinc sheeting Control cabinets, various sheet metal parts
I T f
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
37/553
Where possible, arrange for the oil and grease to be recycled. Dispose of via anauthorised person/contractor in accordance with local regulations. Do not dispose ofoil and grease near lakes, ponds, ditches, down drains, or on to soil. Incineration may
be carried out under controlled conditions in accordance with local regulations.Also note that:
- Spills may form a film on water surfaces causing damage to organisms.Oxygen transfer could also be impaired.
- Spillage may penetrate the soil causing ground water contamination.
Special care is needed when removing certain parts from the robot, before scrappingthe part in question. The types of robot on which there are such parts are listed belowtogether with a description of how they should be removed.
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
38/553
The balancing cylinder contains 3 preloaded spiral springs. Before scrapping (meltingdown, or other form of destruction) the springs must be unloaded in a safe way.
The balancing cylinder contains 12 preloaded spiral springs (see Figure 2). Beforescrapping (melting down, or other form of destruction) the springs must be unloadedin a safe way, (see section 1.2.7).
There are different types of balancing cylinder with a preloading force between 45008000 N.
The free length of the unloaded springs is about 300400 mm excluding the length ofthe balancing cylinder.
Spiral spring
L = 470 mm
Double Spiral spring
http://0.0.0.0/http://0.0.0.0/8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
39/553
The normal way to scrap the balancing cylinder is to use a so-called shredder orscrapping mill. All the balancing cylinders can be treated in this way.
All-enclosed scrapping mills in which the scrap is ground to chips, e.g or similar, are available at all major scrap merchants.
If a scrapping mill is not available, the balancing cylinder (except 3HAA 0001-EZ)
can be opened by means of a blowpipe as shown in the sketches (see Figure 3).
- Cut a hole (250 x 150 mm) in the mantel surface and then cut all theuncovered spring. Finally cut a hole (40 mm) in the piston rod, alt. A, or cutoff the piston rod end, alt. B (see Figure 4).
- Cut a hole (250 x 150 mm) in the outer mantel surface and cut the uncoveredspring so it will be possible to cut another hole (200 x 100 mm) in the innermantel surface. Cut the inner spring and cut off the piston rod end (seeFigure 3).
- This type of balancing cylinder has an outer jacket of aluminium, which
means it cannot be opened by means of a blowpipe. Furthermore, thealuminium must be separated from the steel before recycling and this can onlybe done in a shredder or by the manufacturer (see Figure 5).
ca. 250
ca. 200
Cut off Piston rod
http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
40/553
ca. 250
Hole in the Piston rodCut off Spiral spring
Alternative A
ca. 250
Cut off Spiral spring
Cut off Piston rod
Alternative B
Ca 40mm
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
41/553
Description
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
42/553
Contents page
1 Computer System 11.1 Interfaces of the computer system.................................................. 1
1.1.1 Main computer board........................................................... 1
1.1.2 Axis computer board............................................................ 1
1.1.3 I/O computer board.............................................................. 1
1.1.4 Optional boards ................................................................... 1
2 Servo System 3
2.1 Principle function............................................................................. 3
2.2 Regulation ....................................................................................... 3
2.3 Controlling the robot ........................................................................ 3
2.4 Motor Overload................................................................................ 4
3 I/O System 5
4 Safety System 7
4.1 The chain of operation..................................................................... 7
4.2 MOTORS ON and MOTORS OFF modes....................................... 8
4.3 Safety stop signals .......................................................................... 8
4.4 Limitation of velocity ........................................................................ 9
4.5 ENABLE .......................................................................................... 9
4.6 24V supervision............................................................................... 9
4.7 Monitoring........................................................................................ 9
5 External Axes 11
Description Contents
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
43/553
page
Computer System
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
44/553
1 Computer System
1.1 Interfaces of the computer system
The computer system is made up of three computers boards (see Figure 1). Thecomputer system comprises: Main Computer Board, Axis Computer Board, and I/OComputer Board.
The computers are the data processing centre of the robot. They possess all the
functions required to create, execute and store a robot program. They also containfunctions for coordinating and regulating the axis movements. Figure 1shows howthe computer system communicates with the other units.
In addition to these boards it is possible to add up to five Optional Boards foradditional functionality.
1.1.1 Main computer board
The Main Computer Board contains the main computerof the robot and controls theentire robot (Man-Machine Interface, execution of RAPID programs, path control ofthe robot).
1.1.2 Axis computer board
Regulates the speed and position of up to seven axes. Set points for positions are sent
from the main computer to the axis computer.The axis computer receives position set values from the main computer and currentposition from the serial measurement board. The axis computer uses this data inregulating algorithms and transmits the torque set value and the position values to thedrive system.
1.1.3 I/O computer board
This is the link between the main computer and the process equipment, e.g I/O units.
To find out where the various boards are located, see Chapter 9,Installation andCommissioning.
Computer System Computer System
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
45/553
See also note1, note2and note3
Figure 1 The interfaces of the computer system.
Ethernet (LAN) Serial portsMC/CONSOLE1, COM12
USB
Flash disk
Floppy diskdrive (Option)
Cooling fansMain computer
SMBusBattery unit
Computer powersupply
Process powersupply
Axis computer
I/O computer
Optional board
(0-5)
Ethernet (Service)Enable 1
TPU
Panel unit
Test inputs
Drive system 1Measurement system 2
Drive system 2
Enable 2
PCI bus
Measurement system 1
I/O units (Optional)
See Figure 2
See Figure 3
See Figure 3
See Figure 3
I/O units (Optional)
Gateway units (Optional)
Field bus I/O (Optional
Serial channels COM23, COM33
CAN
CAN
Gateway units (Optional)
Servo System
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
46/553
2 Servo System
2.1 Principle function
The servo system is a complex system comprising several different interacting unitsand system parts both hardware and software. The servo function comprises:
- Digital regulation of the position, velocity and motor current of the robot axes.
- Synchronous AC operation of the robot motors.
2.2 Regulation
During execution, new data on the position of the robot axes is continuously receivedfrom the serial measurement board. This data is received by the position regulator andcompared with previous position data. After it has been compared and amplified, newreferences are given for the position and velocity of the robot.
The system also contains a model of the robot which continuously calculates theoptimal regulator parameters regarding gravity, moment of inertia and interactionbetween axes. See Figure 2.
2.3 Controlling the robot
A digital current reference for two phases is calculated on the basis of the resolversignal and a known relationship between the resolver angle and rotor angle. The thirdphase is created from the other two.
The current of the three phases is regulated in the drive unit in separate currentregulators. In this way, three voltage references are returned which, by pulse-modulating the rectifier voltage, are amplified to the working voltage of the motors.
The serial measurement board receives resolver data from a maximum of six resolversand generates information on the position of the resolvers.
The following diagram (Figure 2) outlines the system structure for AC operation aswell as the fundamental structure of the drive unit.
Servo System Servo System
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
47/553
Figure 2 System structure for AC operation.
2.4 Motor Overload
PTC resistance is built into the robot motors to provide thermal protection againstoverloads. The PTC sensors are connected to an resistance sensitive input on the panelunit which monitors that a low level of resistance is maintained.
The robot computer checks the motors for overloading at regular intervals by readingthe panel unit register. In the event of an overload, all the motors are switched off.
Computer
Serial measurementboard
DC Link Drive unit M R
Torquereference
Rotorposition
CurrentEstimator
M
M
M
U
W
V
M
DC Link
Drive System 1/2
Measurement System 1/2
PWM
PWM
PWM
PWM
Powercircuits
I/O System
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
48/553
3 I/O System
Communicates with other equipment using digital and analog input and outputsignals.
Floppy disk
Flash disk
ATA / EIDE
USB
RS 232
COM1
1
Main Computer
I/O ComputerTPU
Ethernet (Service)
GeneralSerial ports
Gateway
unit
I/O unit (s)
Panel unit
RS 422
RS 232
COM32
COM22
I/O I/O I/O
16
16
CAN2
CAN1
PCI bus
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
49/553
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
50/553
Safety System Safety System
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
51/553
The safeguarded stop GENERAL STOP is active in all operating modes and isconnected by the user.
The aim of these safeguarded stop functions is to make the area around themanipulator safe while still being able to access it for maintenance and programming.
If any of the dual switches in the safety circuit are opened, the circuit breaks, themotor contactors drop out, and the robot is stopped by the brakes. If the safety circuitbreaks, an interrupt call is sent directly from the panel unit to the computer system toensure that the cause of the interrupt is indicated.
When the robot is stopped by a limit switch, it can be moved from this position byjogging it with the joystick while pressing the MOTORS ON button. The MOTORSON button is monitored and may be depressed for a maximum of 30 seconds.
LEDs for ES, AS and GS are connected to the two safety circuits to enable quicklocation of the position where the safety chain is opened. The LEDs are located on theupper part of the panel unit. Status indication is also available on the TPU display.
4.2 MOTORS ON and MOTORS OFF modes
The principle task of the safety circuit is to ensure that the robot goes into MOTORSOFF mode as soon as any part of the chain is opened. The computer system itselfcontrols the last switch.
In AUTO mode, you can switch the robot back on by pressing the MOTORS ONbutton on the operators panel. If the circuit is OK, the computer system will close theSolid state switch to complete the circuit.
When switching to MANUAL, the mode changes to MOTORS OFF and the computer
system opens the Solid state switch.
In any of the MANUAL modes, you can start operating again by pressing the enablingdevice on the Teach Pendant Unit. If the circuit is OK, the computer system will closethe Solid state switch to complete the circuit.
4.3 Safety stop signals
According to the safety standard ISO/DIS 11161 Industrial automation systems -safety of integrated manufacturing systems - Basic requirements, there are twocategories of safety stops, category 0 and category 1. A safety analysis will showwhether category 0 or 1 is applicable, see Table 1below.
All the robots safet stops are categor 0 stops as defa lt Safet stops of categor 1
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
52/553
Safety System Safety System
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
53/553
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
54/553
External Axes External Axes
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
55/553
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
56/553
Installation and Commissioning Contents
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
57/553
page
2.9 External safety relay.........................................................................232.10 Safeguarded space stop signals ......................................................24
2.10.1 Delayed safeguarded space stop .........................................24
2.11 Available voltage..............................................................................24
2.11.1 24V I/O supply ...................................................................... 24
2.11.2 115/230 VAC supply ............................................................. 25
2.12 External 24V supply .........................................................................252.13 Connection and address keying of the CAN-bus .............................26
2.13.1 CAN 1.1 - 1.3........................................................................26
2.13.2 CAN 2 ...................................................................................27
2.13.3 DeviceNet Connector ...........................................................28
2.13.4 ID setting ..............................................................................28
2.14 Distributed I/O units..........................................................................29
2.14.1 General.................................................................................29
2.14.2 Sensors ................................................................................29
2.14.3 Digital I/O DSQC 328 (optional)............................................30
2.14.4 AD Combi I/O DSQC 327 (optional) .....................................32
2.14.5 Analog I/O DSQC 355 (optional) .......................................... 34
2.14.6 Encoder interface unit DSQC 354 ........................................38
2.14.7 Relay I/O DSQC 332 ............................................................ 40
2.15 Digital 120 VAC I/O DSQC 320........................................................42
2.16 Field bus, master/slave ....................................................................45
2.16.1 Profibus-DP m/s DSQC 510 .................................................45
2.16.2 Examples of how to connect Profibus to the robot system...472.17 Gateway (Field bus) units ................................................................48
2.17.1 RIO (Remote Input Output), remote I/O for Allen-Bradley PLCDSQC 350 ............................................................................48
2 17 2 Interbus S slave DSQC 351 50
Contents Installation and Commissioning
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
58/553
page
3.1.2 Installation of the RobotWare on the PC.............................. 633.1.3 Additional content on the RobotWare CD-ROM .................. 63
3.1.4 The manipulator parameter disk: ......................................... 63
3.2 Installing new Robot Controller Software with RobInstall................ 64
3.2.1 How to use RobInstall .......................................................... 64
3.3 Create a new Robot Controller System........................................... 65
3.3.1 Setting up the system .......................................................... 653.3.2 Add or remove external options........................................... 66
3.3.3 Add or remove additional system parameters ..................... 66
3.3.4 Change options or system pack revision ............................. 66
3.4 Update the Robot Controller image................................................. 67
3.5 Transfer Robot Controller System using Ethernet connection ........ 68
3.5.1 Set up before downloading a Robot Controller System....... 68
3.5.2 Download Robot Controller System..................................... 69
3.6 Transfer Robot Controller System using floppy disks...................... 70
3.6.1 Set up before Robot Controller System transfer.................. 70
3.6.2 Create Boot Diskettes from RobInstall................................. 70
3.7 RobInstall preferences .................................................................... 71
4 Robot Controller 73
4.1 BootImage....................................................................................... 73
4.2 Start window.................................................................................... 73
4.3 Reboot............................................................................................. 73
4.4 Boot Disks ....................................................................................... 74
4.5 Network Settings ............................................................................. 74
4.5.1 LAN Settings........................................................................ 74
4.5.2 Service Settings................................................................... 75
4 6 Select System 76
Installation and Commissioning Contents
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
59/553
page
5 Calibration 81
5.1 Updating the revolution counter .......................................................81
5.2 How to use the disk, Manipulator Parameters .................................81
5.2.1 Robot delivered with controller software installed................. 81
5.2.2 New controller software installed with RobInstall..................81
6 System directory structure 83
6.1 Media Pool in the PC .......................................................................83
6.1.1 Media Pool directory.............................................................83
6.2 System Pool in the PC .....................................................................83
6.2.1 System Pool directory...........................................................84
6.2.2 Preparation of S4Cplus software to be installed...................84
6.3 File structure in the robot controller mass storage memory.............85
6.3.1 Check Storage Capacity .......................................................85
6.3.2 Increase Storage Capacity ...................................................86
Installation and Commissioning
1 On Site Installation
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
60/553
1 On-Site Installation
1.1 Transporting and Unpacking
Before starting to unpack and install the robot system, read the safety regulationsand other instructions very carefully. These are found in separate sections in theUsers Guide and Product manual.
The installation must be done by qualified installation personnel and should con-
form to all national and local codes.
When you have unpacked the cabinet, check that it has not been damaged duringtransport or while unpacking.
Operating conditions:
Ambient temperature + 5C to + 45C (direct air cooling)
Ambient temperature + 5C to + 52C (Peltier cooling)
Relative humidity Max. 95% at constant temperature
Storage conditions:
If the equipment is not going to be installed straight away, it must be stored in a dryarea with an ambient temperature between -25C and +55C.
The net weight of the cabinet is approximately: 240 kg
1.2 System CD ROM and diskette
The System CD ROM and the Manipulator parameter disk are delivered with therobot system (see section 3.1.1).
Installation and Commissioning On-Site Installation
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
61/553
1.3 Lifting the Cabinet
Use the four lifting devices on the cabinet or a fork lift when lifting the controller,(see Figure 1).
Figure 1 The maximum angle between the lifting straps when lifting the controller.
If the controller is supplied without its top cover, lifting devices must not be used.
Instead, use a fork lift truck.
A
A
A - A
Min. 60
On-Site Installation Installation and Commissioning
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
62/553
1.4 Amount of space required
200
950
980 *
500
500
820
Lifting points* Castor wheels, Option 126
800
250
Extended cover
Option 123
Cabinet extension
Option 124
for forklift
200
Air distance to wall
800
70
Installation and Commissioning On-Site Installation
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
63/553
1.5 Bolting the cabinet
The cabinet may be secured to the floor using M10 screws (see Figure 3).
Figure 3 Footprint drawing
1.6 Connecting the manipulator to the controller
Two cables are used to connect the controller to the manipulator, one for measuringsignals and the other for motor and brakes.
The connections on the manipulator are located on the rear of the robot base.
1.6.1 Connection on left-hand side of cabinet
The cables are connected to the left side of the cabinet using an industrial connectorand a Burndy connector (see Figure 4).
Figure 4 Connections on the cabinet wall.
400
720
XS2
XS1
Motor cable XP1
Measurementcable XP2
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
64/553
Installation and Commissioning On-Site Installation
Cable connectors are supplied (option 132 - 134).
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
65/553
pp p
Figure 6 Mains connection via an optional wall socket.
1.8 Inspection before start-up
Note! Keep the front door and the top lid closed to prevent the intrusion of dirt and dust.Before power on, check that the following have been performed:
1. The controller mains section is protected with fuses.
2. The electrical connections are correct and correspond to the identification plate onthe controller.
3. The teach pendant and peripheral equipment are properly connected.
4. That limiting devices that establish the restricted space (when utilised) areinstalled.
5. The physical environment is as specified.
6. The operating mode selector on the operators panel is in the Manual modeposition.
When external safety devices are used, check that these have been connected or thatthe following circuits in either XS3(connector on the outside left cabinet wall) or X1-X4(screw terminals on the panel unit) are strapped.
XS3 Panel unit
External limit switches A5-A6, B5-B6 X1.3-4, X2.3-4
External emergency stop A3-A4, B3-B4 X1.9-10, X2.9-10
External emergency stop internal 24 V, A1-A2, B1-B2 X1.7-8, X2.7-8
General stop + A11-A12, B11-B12 X3.10-12, X4.10-12
General stop A13 A14 B13 B14 X3 7 8 X4 7 8
CEE connector DIN connector
On-Site Installation Installation and Commissioning
1 9 St t
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
66/553
1.9 Start-up
1.9.1 General
1. Switch on the mains switch on the cabinet.
2. The robot performs its self-test on both the hardware and software. This test takesapproximately 1 minute.
If the robot is supplied with software already installed, proceed to pos. 3 below.
Otherwise continue as follows (no software installed):3. Install the software as described in chapter 3.
4. A welcome message is shown on the Teach Pendant Unit display.
5. To switch from MOTORS OFF to MOTORS ON, press the enabling device on theteach pendant.
6. Update the revolution counters as described in chapter 15:Repairs, Calibration.
7. Check the calibration position as described in chapter 15:Repairs, Calibration.
8. When the controller, with the manipulator electrically connected, is powered up forthe first time, ensure that the power supply is connected for at least 36 hourscontinuously, in order to fully charge the batteries for the serial measurementboard. It takes approx. 4 hours to fully charge a computer system battery.
9. After having checked the above, verify that
- the start, stop and mode selection (including the key lock switches) control deviceswork as intended.
- each axis moves and is restricted as intended.
- emergency stop and safety stop (where included) circuits and devices are func-tional.
- it is possible to disconnect and isolate the external power sources.
- the teach and playback facilities work correctly.
- the safeguarding is in place.- at reduced speed, the robot operates properly and has the capability to handle the
product or workpiece.
- in automatic (normal) operation, the robot operates properly and has the capabilityf h i d d k h d d d l d
Installation and Commissioning On-Site Installation
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
67/553
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
68/553
Installation and Commissioning Connecting Signals
2 3 Interference elimination
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
69/553
2.3 Interference elimination
Internal relay coils and other units that can generate interference inside the controllerare neutralised. External relay coils, solenoids, and other units must be clamped in asimilar way. Figure 7illustrates how this can be done.
Note that the turn-off time for DC relays increases after neutralisation, especially if adiode is connected across the coil. Varistors give shorter turn-off times. Neutralisingthe coils lengthens the life of the switches that control them.
Figure 7 Examples of clamping circuits to suppress voltage transients.
2.4 Connection types
I/O, external emergency stops, safety stops, etc., can be supplied on screw connectionsor as industrial connectors.
Designation
X(T) Screw terminal
XP Pin (male)
+24V DC +0V
+24V DC, or AC voltage +0V
The diode should be dimensioned for thesame current as the relay coil, and a voltage of twice the supply voltage.
The varistor should be dimensioned for thesame energy as the relay coil, and a voltageof twice the supply voltage.
R 100 ohm, 1WC 0.1 - 1 mF> 500 V max. voltage125 V nominal voltage
R C
Connecting Signals Installation and Commissioning
2 5 Connections
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
70/553
2.5 Connections
Detailed information about connection locations and functions will be found inchapter 12, Circuit Diagram.
2.5.1 Shield grounding
To avoid getting distortions into the robot controller that can interrupt the functionalityof the controller, it is very important that the shield of the cable is grounded to the
controllers wall. The grounding of the shield must be made there the cable is enteringthe controller. The cable must go through a cable gland on the controller wall wherethe cable shield must be connected to the cable gland. The cable gland must in turn beconnected to the controllers wall with screws with scratches to get a good groundingbetween the cable gland and the robot controllers wall.
2.5.2 To screw terminal
Panel unit and I/O units are provided with keyed screw terminals for cables with anarea between 0.25 and 1.5 mm2. A maximum of two cables may be used in any oneconnection.
Note! The cable shield must be connected to the cabinet wall using EMC connectingcable glands. The shield must continue right up to the screw terminal.
The installation should comply with the IP54 (NEMA 12) protective standard.
Bend unused conductors backwards and attach them to the cable using a clasp, orsimilar. To prevent interference, ensure that such conductors are not connected at theother end of the cable (antenna effect). In environments with much interference,disconnected conductors should be grounded (0V) at both ends.
2.5.3 To connectors (option)
Industrial connectors with 4x16 pins for contact crimping (complies with DIN 43652)
can be found on the left-hand side or front of the cabinet (depending on the customer
Installation and Commissioning Connecting Signals
order) See Figure 8and Figure 5.
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
71/553
Figure 8 Positions for connections on the left-hand side of the controller.
In each industrial connector there is space for four rows of 16 conductors with amaximum conductor area of 1.5 mm2. The pull-relief clamp must be used whenconnecting the shield to the case.
The manipulator arm is equipped with round Burndy/Framatome connectors(customer connector not included).
Bend unused conductors backwards and attach them to the cable using a clasp, orsimilar. To prevent interference, ensure that such conductors are not connected at theother end of the cable (antenna effect). In environments with much interference,disconnected conductors should be grounded (0V) at both ends.
When contact crimping industrial connectors, the following applies:
1. Using a special crimp tool, crimp a pin or socket on to each non-insulatedconductor
Operators panel
in separate cabinetExternal axes Safety signals
External conn. Device Net
Mains conn.
I/O connections
External axes inRobot cabinet
ApplicationInterface Manipulator cables
EquipmentPosition switchesconnection to cabinet
Connecting Signals Installation and Commissioning
2.6 Connection to screw terminal
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
72/553
2.6 Connection to screw terminal
Sockets with screwed connections for customer I/O, external safety circuits, customersockets on the robot, external supply to electronics. See also note1.
Locations of socket terminals are shown in Figure 9. See also circuit diagram, Viewof control cabinet, for more details.
Signal identification Location Terminals
Safeguarded stop Panel unit X1 - X4
Digital I/O I/O unit X1 - X4
Combi I/O I/O unit X1 - X4, X6
Relay I/O I/O unit X1 - X4
RIO I/O I/O unit X1, X2
COM21, COM31 Base Connector Unit X10, X9
CAN 1.1 (internal unit) Base Connector Unit X15
CAN 1.2 (manipulator, I/O units) Base Connector Unit X6
CAN 1.3 (external I/O units) Base Connector Unit X7
CAN 2 (external I/O units) Base Connector Unit X824V supply (2A fuse) XT31
115/230V AC supply XT21
Table 3 Connections to screw terminal
Installation and Commissioning Connecting Signals
X7 (CAN 1.3) X8 (CAN 2)X6 (CAN 1.2)
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
73/553
Cabinet view from above
X9 (COM31)
X15 (CAN1.1)
Computer system
Base Connector Unit
I/O Units (X4)
X 1 - X 4Safety Signals
X10 (COM21)
XT 31(24V I/O)
(COM11)
Panel Unit
Manipulator connections115/230 VAC
Connecting Signals Installation and Commissioning
2.7 The MOTORS ON / MOTORS OFF circuit
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
74/553
To set the robot to MOTORS ON mode, two identical chains of switches must beclosed. If any switch is open, the robot will switch to MOTORS OFF mode. As longas the two chains are not identical, the robot will remain in MOTORS OFF mode.Figure 10shows an outline principle diagram of the available customer connections,AS, GS and ES.
Figure 10 MOTORS ON /MOTORS OFF circuit.
AS
Automatic mode
Solid State Switches Contactor
Operating mode selector
ED = TPU Enabling Device
AS = Automatic mode safeguarded space stop
LS = Limit Switch
ES = Emergency Stop
EN1
GS = General mode safeguarded space stop
MEN2RUN
2:ndchain
interlock
Driveunit
&
GS
ED
LS
Manual mode
Computer commands
Mains
ES
Installation and Commissioning Connecting Signals
2.7.1 Connection of safety chainsExt LIM1 K11
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
75/553
Figure 11 Diagram showing the two-channel safety chain, see also note1.
Technical data per chain
Limit switch: loadmax. V drop
300 mA1V
External contactors: load 10 mA
Man1Auto1
Man2Auto2
X1:11
X3:10
X2:11
X4:10
X4:3
X3:3
X3:71
9
12
11
8
4
4
9
11
8
12
Ext LIM2
External contactors
Ext LIM1
GS1
AS1
TPU En1
ES1
Optoisol.
Optoisol.
& EN
RUN Inter-
locking
K1
K2
K1
0 V
K2
M
Drive unit
AS2
GS2
ES2
TPU En2 &
24V1
See 2.7.2
Opto
isol.
Opto
isol.
24 V
24 V
CONT1
CONT2
24V
X4:7
0V
+
+
-
-
0 V
0 V
+
+
-
-
X3:12X4:12
See 2.7.2
Connecting Signals Installation and Commissioning
2.7.2 Connection of ES1/ES2 on panel unitInternal
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
76/553
24V 0V
X1:4 X1:3X1:7
X1:9X1:10
TPU Cabinet
X1:1
X1:2
X1:6
24V
ES1 Internal
24V
Run Chain 1 top
X1:4
X1:5
Internal
24V 0V
X2:4 X2:3
X2:7X2:9X2:10
TPU Cabinet
X2:1
X2:2
X2:6
24V
ES2 Internal
24V
Internal
X1:8
X2:8
Ext. stop
Ext. stop
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
77/553
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
78/553
Installation and Commissioning Connecting Signals
2.8 External customer connections on panel unit X1X4
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
79/553
Figure 16 Customer connections: X1X4, located on the panel unit.
2.8.1 X1; 12-pole type Phoenix COMBICON connector
See also note1.
Signal
1
Terminal no: CommentES1 out:A 1 Emergency stop out chain 1
ES1 out:B 2 Emergency stop out chain 1
ES1 top 3 Top of emergency stop chain 1
24Vpanel 4 +24V emergency stop chain 1 and run chain 1
Run Ch1 top 5 Top of run chain 1
ES1 internal 6 Internal signal from emergency stop relay chain 1
Sep. ES1:A 7 Separated emergency stop chain 1
Sep. ES1:B 8 Separated emergency stop chain 1
ES1 bottom 9 Bottom of emergency stop chain 1
0V 10 0V emergency stop chain 1
AS2AS1GS1ES2ES1 GS2NSMSEN
WARNING!REMOVE JUMPERS BEFORE CONNECTING
ANY EXTERNAL EQUIPMENT
X1
X2
X3
X4
Chain statusLEDs
1 2 4 53 6 7 8 9 10 1211
1 2 4 53 6 7 8 9 10 1211 1 2 4 53 6 7 8 9 10 1211
1 2 4 53 6 7 8 9 10 1211
= jumper
Connecting Signals Installation and Commissioning
2.8.2 X2, 12-pole type Phoenix COMBICON connector
See also note1
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
80/553
See also note .
2.8.3 X3; 12-pole type Phoenix COMBICON connector.
Signal1 Terminal no: Comment
ES2 out:A 1 Emergency stop out chain 2
ES2 out:B 2 Emergency stop out chain 2
ES2 top 3 Top of emergency stop chain 2
0V 4 0V emergency stop chain 2 and run chain 2
Run Ch2 top 5 Top of run chain 2ES2 internal 6 Internal signal from emergency stop relay chain 2
Sep. ES2:A 7 Separated emergency stop chain 2
Sep. ES2:B 8 Separated emergency stop chain 2
ES2 bottom 9 Bottom of emergency stop chain 2
24Vpanel 10 24V emergency stop chain 2
Ext. LIM2:A 11 External limit switch chain 2
Ext. LIM2:B 12 External limit switch chain 2
Table 10 Signal descriptions for X2
Signal1 Terminal no: Comment
Ext. MON 1:A 1 Motor contactor 1
Ext. MON 1:B 2 Motor contactor 1
0V 3 External contactor 1 0V
CONT1 4 External contactor 1
5 No connect
6 No connect
0V 7 0V to auto stop and general stop
GS1 - 8 General stop minus chain 1
AS1 - 9 Auto stop minus chain 1
GS1 + 10 General stop plus chain 1
AS1 11 A l h i 1
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
81/553
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
82/553
Installation and Commissioning Connecting Signals
2.10 Safeguarded space stop signals
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
83/553
According to the safety standard ISO/DIS 11161 Industrial automation systems -safety of integrated manufacturing systems - Basic requirements, there are twocategories of safety stops, category 0 and category 1. A safety analysis will show ifcategory 0 or 1 is applicable, see Table 13below.
2.10.1 Delayed safeguarded space stop
All the robots safety stops are as default category 0 stops.Safety stops of category 1 can be obtained by activating the delayed safeguardedspace stop together with AS or GS. A delayed stop gives a smooth stop. The robotstops in the same way as a normal program stop with no deviation from theprogrammed path. After approx. 1 second the power supply to the motors is shut off.The function is activated by setting a parameter, see Users Guide - SystemParameters, Topic: I/O Signals.
2.11 Available voltage
2.11.1 24V I/O supply
The robot has a 24V supply available for external and internal use.
The 24V I/O is not galvanically separated from the rest of the controller voltages.
Technical data
Voltage 24.0 - 26.4VRipple Max. 0.2V
Category 0 Category 1
The category 0 stop is to be used when the powersupply to the motors must be switched off imme-
diately, such as when a light curtain, used to pro-tect against entry into the work cell, is passed.This uncontrolled motion stop may require spe-cial restart routines if the programmed pathchanges as a result of the stop.
Category 1 is preferred if it is acceptable, such aswhen gates are used to protect against entry into
the work cell. This controlled motion stop takesplace within the programmed path, which makesrestarting easier.
Table 13 Description of safety categories
Connecting Signals Installation and Commissioning
2.11.2 115/230 VAC supply
The robot has an AC supply available for external and internal use.
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
84/553
pp y
This voltage is used in the robot for supplying optional service outlets.
The AC supply is not galvanically separated from the rest of the controller voltages.
Technical data
Voltage 115 or 230VPermitted customer load Max. 500VAFuse size 3.15A (230V), 6.3A (115V)
AC supply is available for customer connections at XT 21 see Figure 9.
XT.21.1-5 230V (3.15A)XT.21.6-8 115V (6.3A)XT.21.9-13N (connected to cabinet structure)
2.12 External 24V supply
An external supply must be used in the following cases:
- When the internal supply is insufficient
- When the emergency stop circuits must be independent of whether or not the robothas power on, for example.
- When there is a risk that major interference can be carried over into the internal24V supply
An external supply is recommended to make use of the advantages offered by thegalvanic insulation on the I/O units or on the panel unit.
The neutral wire in the external supply must be connected in such a way as to preventthe maximum permitted potential difference in the chassis earth being exceeded. Forexample, a neutral wire can be connected to the chassis earth of the controller, or someother common earthing point.
Technical data:
Potential difference to chassis earth: Max. 60V continuousMax. 500V for 1 minute
Permitted supply voltage: I/O units 1935V including ripplepanel unit 20 630V including ripple
Installation and Commissioning Connecting Signals
2.13 Connection and address keying of the CAN-bus
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
85/553
2.13.1 CAN 1.1 - 1.3.
X15 CAN1.1 (Internal I/O) No termination of
the last unit
X7 CAN1.3
X6 CAN1.2
Base connector unit
I/O I/O I/O
I/O
I/O
I/O I/O
I/O
I/OSee Figure 22.
CAN bus
Control cabinet
Termination of
Connecting Signals Installation and Commissioning
- CAN 1.1 is used for internal I/O unit mounted inside the cabinet. No terminatingresistor is to be mounted on CAN 1.1 regardless of whether there are any I/O unitsmounted or not. CAN 1.1 is connected to socket X15 on the Base connector unit
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
86/553
(see 2.6).
- If CAN 1.2 is unused there should be a terminating resistor mounted in the X6socket (exceptional case see below).
- If CAN 1.2 is used, the terminating resistor should be moved to the last I/O uniton the CAN 1.2 chain.
- If CAN 1.3 is unused there should be a terminating resistor mounted in the X7socket (exceptional case see below).
- If CAN 1.3 is used, the terminating resistor should be moved to the last I/O uniton the CAN 1.3 chain.
Note! If CAN 1.2, for example, is not connected in the end of any CAN chain but some-where between the end points of the chain, then no terminating resistor should bemounted in CAN 1.3. This is in accordance with the basic rule, i.e. the CAN chainshould be terminated in both end points.
2.13.2 CAN 2
Figure 19 CAN 2
24 CA i i i
I/OI/OI/O
Base connector unit
1. 0V_CAN2. CAN_L3. drain
4. CAN_H5. 24V_I/O
X8 1. 0V_CAN2. CAN_L3. drain
4. CAN_H5. 24V_I/O
1.2.3.
4.5.
Termination oflast unit
120 W, 1%0.25 W Metal film
Controller
X8 CAN 2
See Figure 20
Installation and Commissioning Connecting Signals
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
87/553
Figure 20 CAN connections on base connector unit.
2.13.3 DeviceNet Connector
X5
Input and ID Signal name Pin Description
V- 0V 1 Supply voltage GND
CAN_L 2 CAN signal low
DRAIN 3 ShieldCAN_H 4 CAN signal high
V+ 5 Supply voltage 24VDC
GND 6 Logic GND
MAC ID 0 7 Board ID bit 0 (LSB)
MAC ID 1 8 Board ID bit 1
MAC ID 2 9 Board ID bit 2
MAC ID 3 10 Board ID bit 3
MAC ID 4 11 Board ID bit 4
MAC ID 5 12 Board ID bit 5 (MSB)
T bl 14 Si l d i i f X5
X15 CAN 1.1 (Internal I/O)
X6 CAN 1.2 (External I/O)
X7 CAN 1.3 (External I/O)
X8 CAN 2 (External I/O)
1
12
Connecting Signals Installation and Commissioning
6 8 9 10 11 127
(0V)
1 2 3 4 5
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
88/553
Figure 21 Examples of address keying.
2.14 Distributed I/O units
2.14.1 General
Up to 201units can be connected to the same controller but only four of these can beinstalled inside the controller. Normally a distributed I/O unit is placed outside thecontroller. The maximum total length of the distributed I/O cable is 100 m (from oneend of the chain to the other end). The controller can be one of the end points or beplaced somewhere in the middle of the chain. For setup parameters, see Users Guide,section System Parameters, Topic: I/O Signals.
2.14.2 Sensors
S t d t ti l di it l it
X5 connec-tor
address pins
address key
1 48
16322
Example:
To obtain address 10:cut off address pins 2 and 8, see figure.
To obtain address 25:cut off address pins 1, 8 and 16.
Installation and Commissioning Connecting Signals
The following sensors can be connected:
Sensor type Signal level
Di it l bit Hi h 1
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
89/553
2.14.3 Digital I/O DSQC 328 (optional)
The digital I/O unit has 16 inputs and outputs divided up into groups of eight. Allgroups are galvanically isolated and may be supplied from the cabinet 24V I/O supplyor from a separate supply.
Technical data
See Product Specification for controller S4Cplus.
Further information
For setup parameters, see Users Guide - System Parameters, Topic: I/O Signals. ForCircuit diagram, see Chapter 12.
Connection table
Customer connections X1X4
Digital one bit sensors High 1
Low 0
Digital two bit sensors High 01
No signal 00
Low 10
Error status 11(stop program running)
Table 15 Sensors
OUT
INNS
MS16151413121110987654321
OUT
IN
X1
X3
X2
X4
101101
101 101
Status LEDs
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
90/553
Installation and Commissioning Connecting Signals
2.14.4 AD Combi I/O DSQC 327 (optional)
The combi I/O unit has 16 digital inputs divided into groups of 8, and 16 digital
outputs divided into two groups of 8 All groups are galvanically isolated and may be
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
91/553
outputs divided into two groups of 8. All groups are galvanically isolated and may besupplied from the cabinet 24 V I/O supply or from a separate supply.
The two analog outputs belong to a common group which is galvanically isolatedfrom the electronics of the controller. The supply to the two analog outputs isgenerated from24 V_CAN (with galvanically isolated DC/AC converter).
Technical data
See Product Specification for controller S4Cplus.
Further information
For setup parameters, see Users Guide - System Parameters, Topic: I/O Signals. ForCircuit diagram, see chapter 12.
Connection Table
Customer connections X1X4, X6.
Figure 23 AD Combi I/O DSQC 327
OUT
INNS
MS16151413121110987654321
OUT
IN
X1
X3
X2
X4
X6
1 10 101
1 6101 101
Status LEDs
X5
112
CAN-connection, see 2.13
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
92/553
Installation and Commissioning Connecting Signals
Connector X6
X6
Signal name Pin Explanation
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
93/553
Note! The input current is 5.5 mA (at 24V) on the digital inputs. A capacitor connectedto ground, to prevent disturbances, causes a short rush of current when setting theinput. When connecting outputs, sensitive to pre-oscillation current, a series resis-tor (100 ) may be used.
2.14.5 Analog I/O DSQC 355 (optional)
The analog I/O unit provides the following connections:
4 analog inputs, -10/+10V, which may be used for analog sensors etc.
4 analog outputs, 3 for -10/+10V and 1 for 4-20mA, for control of analog functionssuch as controlling gluing equipment etc.
24V to supply external equipment with return signals to DSQC 355.
Technical data
See Product Specification for controller S4Cplus.
Further information
For setup parameters, see Users Guide -System Parameters, Topic: I/O Signals. ForCircuit diagram, see chapter 12.
S g p
AN_ICH1 1 For test purpose only
AN_ICH2 2 For test purpose only
0V 3 0V for In 1-2
0VA 4 0V for Out 1-2
AN_OCH1 5 Out ch 1
AN_OCH2 6 Out ch 2
Table 20 Connection table, X6
Connecting Signals Installation and Commissioning
Connection table
Customer connections: X1, X3, X5X8
X8-Analog inputs X7-Analog outputs
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
94/553
Figure 24 Analog I/O unit
Connector X5 DeviceNet connectors.
See section 2.13.3.
DSQC 355 ABB flexible Automation
Bus status LEDs
Analog I/O
X8
S3S2
X3X5
X2
X7
g p g p
X5-DeviceNet input Not to be usedand ID connector
Installation and Commissioning Connecting Signals
Connector X7 - Analog outputs.
X7
Signal name Pin Description
8/9/2019 S4CPlus-Product Manual IRB 6400R M2000_rev02
95/553
Note! The input current is 5.5 mA (at 24V) on the digital inputs. A capacitor connectedto ground, to prevent disturbances, causes a short rush of current when setting theinput. When connecting outputs, sensitive to pre-oscillation current, a series resis-tor (100 ) may be used
ANOUT_ 1 Analog output 1, -10/+10
ANOUT_ 2 Analog output 2, -10/+10
ANOUT_ 3 Analog output 3, -10/+10
ANOUT_ 4 Analog output 4, 4-20mA
Not to be used 5
Not to be used 6Not to be used 7
Not to be used 8
Not to be used 9
Not to be used 10
Not to be used 11
Not to be used 12
Not to be used 13
Not to be used 14
Not to be used 15
Not to be used 16
Not to be used 17
Not to be used 18
GND 19 Analog output 1, 0VGND 20 Analog output 2, 0V
GND 21 Analog output 3, 0V
GND 22 Analog output 4, 0V
GND 23
GND 24
Table 21 Connection table, X7
1
12
13
24
Conn
Top Related