ROOF AND WALL SYSTEMS FOR OVER-CLAD REFURBISHMENT
REFRESH SYSTEMS
Refresh Systems provide a series of standard
systems that can be used to overclad existing
building envelopes that have failed, require
improved thermal or acoustic performance or
have seen better days and are in need of a
facelift.
Types of roof and wall systems that can be
overclad include:
• built-up metal, fibre cement and asbestos roof
and walls
• insulated composite panel roof and walls
• flat roofs with very low pitches
• flat roofs with no pitch.
KEY FEATURES AND BENEFITS
• Refresh is a way of achieving increased building
longevity, whilst utilising the existing structure and
positively transforming exterior building aesthetics
• Refresh systems can be adapted to suit various
existing construction types and achieve a variety
of defined performances
• All Euroclad roof and wall cladding profiles are
CE marked in accordance with BS EN 14782:2006
• All profiles are manufactured under management
systems accredited to industry-recognised
standards for quality, environmental management,
and health and safety: ISO9001, ISO14001 and
OHAS18001
• Euroclad has 36 years experience at the forefront of
the roofing and cladding industry.
Insulation* Quattro Continuous U-Value bracket tophat (Kg/m2) 32/1000 SF500
120mm 80mm ≥ existing profile height 0.57 10.9 11.76
220mm 180mm ≥ existing profile height 0.25 12.21 13.06
300mm 260mm ≥ existing profile height 0.17 13.26 14.10
*Based on 40mm high, 1.6mm gauge, galvanised steel, continuous tophat. Insulation Lambda value 0.040W/mK.
Weight (Kg/m2)*
EXTERNAL PROFILE OPTIONS
System Refresh roof composite or Refresh roof trapezoidal
Existing roof type Metal composite panel or trapezoidal profile
Support structures Existing roof and support structure can be used Must be inspected and approved by independent structural engineer
External sheet profile 32/1000 1F Secret Fix SF500
25 year Refresh guarantee
Material Steel 0.7mm Colorcoat HPS200® Ultra 0.7mm Colorcoat HPS200® Ultra (Up to 40 year Confidex or Colorcoat Prisma® or Colorcoat Prisma® metal guarantee)
Pitch >4° >1°
Spacer systems Quattro fixed to tophat Quattro fixed to tophat
Tophat fixed to existing structure Tophat fixed to existing structure
Vapour control layer Euroclad Elite VCL Euroclad Elite VCL
Insulation Non-combustible mineral fibre Non-combustible mineral fibre
Suitable for all humidity class buildings
Flashings Euroclad Architectural Limited Euroclad Architectural Limited
*Single skin or built-up system.
Premium steel roof which showsno fixings once installed due to ahidden (secret) clip-fixing. SF500can be factory-manufactured orproduced onsite in longcontinuous lengths. It can even be rolled at eaves directly onto abuilding’s prospective roof.
Critical legRunout leg
94mm
1000mm
31mm129˚ 5
22Colour side23
23mm
4
8
39mm
1
Colour side
OverlapUnderlap
17mm 56mm
500mm
53mm 54mm120˚ 120˚63mm
21mm
32/1000F
SF500
WEIGHT AND THERMAL PERFORMANCE
Popular trapezoidal profile,typically supplied in steel. Onemetre cover width, with maximumsheet length of 12m and minimumpitch of 4°.
4 4
4 4
REFRESH ROOF SYSTEMS
SUMMARY SPECIFICATION
32/1000 or SF500 outerprofile (SF500 shown)
Mineral fibreinsulation
Quattro spacer system
REFRESH ROOF COMPOSITE
REFRESH ROOF TRAPEZOIDAL
Continuoustophat section
Euroclad VapourControl Layer (VCL)
Existing compositepanel roof
32/1000 or SF500 outerprofile (32/1000 shown)
Quattro spacer system
Continuoustophat section
Euroclad VapourControl Layer (VCL)
Existing trapezoidal built-up roof
Mineral fibre insulation
Existingpurlin
Office redevelopment, Glasgow.
PROJECT GALLERY
University of South Wales, Cardiff.
BeforeBefore.
Before.
Euro Clad Limited
Wentloog Corporate Park
Cardiff
CF3 2ER
Tel: +44 (0)29 2201 0101
Fax: +44 (0)29 2201 0122
Web: www.euroclad.com
@eurocladuk
The details and information contained in this publication are correct at time of going to press. Euroclad reserves the rightto change details and specifications without prior notice. No responsibility is assumed for errors or misinterpretationsresulting from the information contained in this publication. Typical construction details are illustrative only and no liabilityis accepted. All gauges are nominal. Latest information is available at www.euroclad.com
Top Related