Download - RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

Transcript
Page 1: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

RFP 18-814

Amiss Water Treatment Plant Ozone Equipment

ATTACHMENT #4

Proposed Process and Instrumentation Diagrams

Page 2: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

FC

123099

1

WITHOUTW/O

VORTEX BREAKER

VENT

VACUUM

UNDERGROUND

TYPICAL

TIGHT SHUT-OFF

TANGENT TO TANGENT

TANGENT LINE

VB

W/

VNT

VAC

WITH

T/T

TYP

UG

TSO

TL

PRESSUREPRESS

SAFETY INSTRUMENTED SYSTEM

RESISTANCE TEMP. DETECTOR

THREADED

TOTAL DIFFERENTIAL HEAD

THERMOCOUPLE

TEMPERATURE

STEAM OUT

START/STOP

STANDARD

STAINLESS STEEL

SET POINT

STD

THRD

TEMP

TDH

T/C

S/S

SS

SO

SP

RELOCATED

SPECIFIC GRAVITY

SHUTDOWN

SCHEDULE

SAMPLE CONNECTION

REQUIRED

PROCESS VARIABLE

SD

SIS

SG

SCH

SC

(R)

RTD

REQD

PV

PROGRAMMABLE LOGIC

CONTROLLER

OVERHEAD

OUTSIDE BATTERY LIMITS

OUTPUT

OPEN/CLOSE

ON/OFF

NOZZLE

NORMALLY NO FLOW

NORMALLY OPEN

O/O

PLC

OVHD

OSBL

OP

NOZ

O/C

NNF

NO

LOCKED OPEN

MATERIAL

NORMALLY CLOSED

MOTOR OPERATED VALVE

MINIMUM

MAXIMUM

MANWAY

LOW POINT

LOW PRESSURE

MIN

NC

MW

MTL

MOV

MAX

LPT

LP

LO

INSULATION TYPE CODES

STEAM TRACED

STEAM JACKETED

PROCESS STABILITY INSULATION

PERSONNEL PROTECTION

INSULATION

PREVENTION FROM FREEZING

INSULATION

HOT FLUID TRACED

HOT FLUID JACKETING

HEAT CONSERVATION INSULATION

FIRE PROTECTION INSULATION

ELECTRIC TRACED

CHILLED FLUID TRACED

CONDENSATION CONTROL

CHILLED FLUID JACKETED

COLD SERVICE INSULATION

ACOUSTIC CONTROL INSULATION

CLOSED FIGURE 8 BLIND

BLIND FLANGE

REMOVABLE PLUG

OPEN FIGURE 8 BLIND

BLANK

ST

SJ

PS

HT

PF

PP

HJ

HC

CJ

FP

ET

CP

CT

CC

AC

CONCENTRIC (OR GENERIC)

REDUCER

ECCENTRIC REDUCER

HOSE CONNECTION

SPACER

WELDED CONNECTION

REMOVABLE CAP

FLANGE

PIPING FITTINGS

KNIFE

EXHAUST HEAD

EXCESS FLOW VALVE

DIVERTER VALVE

ROTARY VALVE

IN-LINE MIXER

EXPANSION JOINT

BREATHER

DAMPER

FLEXIBLE HOSE

REMOVABLE SPOOL

VALVES SYMBOLS

FAIL LOCKED (LAST POSITION)

GRADEGR

LOCKED CLOSED

INSTRUMENT AIR SUPPLY

INSIDE BATTERY LIMITS

HOSE CONNECTION

HIGH PRESSURE

HIGH POINT

HEADER

HAND/OFF/AUTOMATIC

HAND HOLE

IAS

ISBL

LC

HPT

HP

HDR

HOA

HH

HC

GEAR OPERATED

FURNISHED

FULL VACUUM

FULL PORT

FLANGE

FAIL OPEN

FAIL INDETERMINATE

FAIL CLOSED

FLG

FV

GO

FP

FO

FI

FL

(F)

FC

DISTRIBUTED CONTROL SYSTEM

DIAMETERDIA

FACE OF FLANGE

EXISTING

EMERGENCY SHUTDOWN

ELEVATION

DRAWING

DRAIN

DIFFERENTIAL PRESSURE

DESIGN TEMPERATURE

DESIGN PRESSURE

DWG

EL

FOF

ESD

(E)

DRN

DT

D/P

DP

DESIGN

CONNECTION

CLEANOUT

CENTERLINE

CENTER

CAR SEAL OPEN

CAR SEAL CLOSED

CHEMICAL CLEANOUT

DCS

DES

CTR

CSO

CO

CONN

CSC

CL

CC

ABBREVIATIONS

BYPASS

BOTTOM TANGENT LINE

BATTERY LIMIT

ATMOSPHERE

ABOVE GROUNDAG

BYP

BTL

ATM

BL

GENERIC ROTARY

(1/4 TURN)

ANGLE

PINCH

4-WAY

DIAPHRAGM

3-WAY

PLUG

BUTTERFLY

NEEDLE

BALL

GLOBE

STOP CHECK

CHECK

VENT SILENCER

IN-LINE SILENCER

PULSATION DAMPENER

EJECTOR/EDUCTOR

TEMPORARY STRAINER

FILTER

BASKET STRAINER

DUPLEX STRAINER

T-TYPE STRAINER

PIPING SPECIALTY ITEMS

GATE (OR GENERIC)

CONICAL STRAINER

Y-TYPE STRAINER

(XX = NOTE NUMBER, ROTATE

T

XXX(XXXX = IDENTIFICATION NUMBER)

INSULATION REQUIREMENT

PIPING SPECIALTY ITEM

IN LINE CLASS OR

POINT OF CHANGE

TIE-IN SYMBOL

ARROW AS REQUIRED)

XX/YY

XXXX

(XXXX = PURGE PRESSURE AND

MEDIUM)

(XX/YY = TYPE/NUMBER)

SAMPLE CONNECTION

PURGE CONNECTION

NOTE REFERENCE SYMBOL

WASTE WATERWW

TEMPERED WATER SUPPLY

TEMPERED WATER RETURN

SANITARY SEWER

SERVICE WATER

STORM SEWER

SEAL OIL

TWS

TWR

STS

SW

SS

SO

SODA ASH

RAW WATER

RELIEF VENT

PROCESS WATER

POLYMER

SA

RW

RV

PW

POLY ALUMINIUM CHLORIDE

POWDERED ACTIVATED CARBON

OXYGEN

AMMONIA

NATURAL GAS

CAUSTIC SEWER

CAUSTIC

NITROGEN

OX

PACL

PAC

NH

NA

NAS

NG

N

MIXED REFRIGERANT

METHANOL

LIQUID OXYGEN

LUBE OIL

INSTRUMENT AIR

HYDROGEN

LOX

MR

ME

IA

H

GASEOUS OXYGEN

GLYCOL RETURN

GLYCOL SUPPLY

FIRE WATER

FUEL OIL

FLUSHING FLUID

FLUORIDE

ETHYLENE REFRIGERANT

DRINKING WATER

FO

GLR

GLS

GOX

FW

FF

F

ER

DW

DEMINERALIZED WATER

COOLING WATER SUPPLY

COOLING WATER RETURN

COLD VENT

CHEMICAL SEWER

COMPRESSED AIR

DMW

DR

CWS

CWR

DRAIN

CHS

CV

CA

MISCELLANEOUS SYMBOLS LINE SERVICE CODES

BLOWDOWN

ATMOSPHERIC VENT

ALUMINIUM SULFATE (ALUM)ALM

BD

AV

WITH REMOTE RESET

WITH POSITIONER AND

TYPICAL CONTROL VALVE

WITH MANUAL RESET

SINGLE SOLENOID

FC

SOLENOID

MOTOR OPERATED

ELECTRO-HYDRAULIC

SINGLE SOLENOID

SINGLE SOLENOID

WITH ANY ACTUATOR

PRESSURE BALANCED

HANDWHEEL - USED

CYLINDER/PISTON

DIAPHRAGM

DIAPHRAGM

INSTRUMENT WITH LONG TAG NUMBER

VALVE TAG - REFER TO SCHEDULE ON D006

SHARING COMMON HOUSING

DUAL FUNCTION OR INSTRUMENTS

MANUAL OPERATOR

PILOT LIGHT OR GAUGE GLASS ILLUMINATOR

CHEMICAL SEAL/DIAPHRAGM

CONTROL VAVLE ACTUATOR SYMBOLS

#

SP

NO

GRADE

DIRECTION OF FLOW (ARROW)

DISMANTLING JOINT (DJ)

AIR RELEASE VALVE

(W/BLIND FLANGE)

WELDOLET

A

S

S

RS

SC

P

M

E/H

S

R

S

R

S

S

NOTES:

1. THIS LEGEND IS TAKEN FROM A STANDARD

PROCESS LEGEND AND NOT ALL ITEMS

OR EQUIPMENT AS DESIGNATED HEREON

ARE USED ON THIS PROJECT.

2. SOME ABBREVIATIONS MAY NOT BE USED.

DRAIN

VENT TO ATMOSPHERE

OR EXTERIOR

PIPE WITH HEATING CABLE

CHLORINE GASCL2

CARBON DIOXIDECO2

CHLORINE DIOXIDECLO2

LO

POL

OZG OZONE GAS

DEMISTER

CONSTANT HEAD

FLOW CONTROLLER

OZONE HEATER

DESTRUCT CATAYST

VAPORIZER

AFTER COOLER

DESSICANT DRYER

DIFFUSER

INJECTION QUILL

CALIBRATION COLUMN

AUTOMATIC FLOW

BALANCE VALVE

CORPORATION STOP

UNION

CONTROL VALVE / BACK

PRESSURE VALVE

WALL PENETRATION

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

FEBRUARY 02, 2017 M. CHARRETTE

R. DRAIN T. McGOWN

AMISS WTP IMPROVEMENTS

PID LEGEND, ABBREVIEATIONS AND

GENERAL NOTES 1

96191 E14003

DI001 D

96191_DI001.dwg

2018

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

PRELIMINARY - NOT

FOR CONSTRUCTION

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400

BONTONASSOCIATES

CIVIL ENGINEERING ENVIRONMENTAL PLANNING

TM01/05/18 RD ISSUED FOR 30%

OWNERS REVIEW

A

TM02/12/18 RD ISSUED FOR

PRESELECTION

B

TM05/31/18 RD ISSUED FOR 60%

OWNERS REVIEW

C

TM12/03/18 RD ISSUED FOR 90%

OWNERS REVIEW

D

Page 3: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

Z POSITION DRIVE, ACTUATORZ-AXIS

Y EVENT, STATE (*) RELAY, COMPUTERY-AXIS

TRANSDUCERUNCLASSIFIED (*)X-AXISX UNCLASSIFIED (*)

WELLW WEIGHT, FORCE

VALVE, DAMPERV VIBRATION

MULTIFUNCTIONAL (*)U MULTIVARIABLE (*)

TRANSMITT TEMPERATURE

SWITCHSAFETYS SPEED, FREQUENCY

RECORD, PRINTR RADIATION

INTEGRATE, TOTALIZEQ QUANTITY

POINT (TEST CONN)P PRESSURE, VAC

OPENEDORIFICEO USERS CHOICE (*)

ON, OPERATEISOLATORUSERS CHOICE (*)N TORQUE

MIDDLE, INTRMDTMOMENTARYM MOISTURE, MOTOR

LOWLIGHTL LEVEL

CONTROL STATIONRATEK TIME, SCHEDULE

SCANJ POWER

INDICATEI CURRENT (AMPS)

HIGHH HAND (MANUAL)

GATEGLASS, VIEWINGG GAUGE

RATIO/BIASF FLOW RATE

EMERGENCYSENSOR (PRIMARY ELEMENT)E VOLTAGE

OPEN,START,INCREASEDIFFERENTIALD DENSITY (SG)

CLOSEDCONTROLC CONDUCTIVITY

USERS CHOICE (*)CLOSE,STOP,DECREASEB BURNER, COMBUSTION USERS CHOICE (*)

ALARMANALYSIS (*)A

MODIFIEROUTPUT FUNCTIONREADOUT OR

PASSIVE FUNCTION

MODIFIERPROCESS OR

INITIATING VARIABLE

SUCCEEDING LETTERLETTER FIRST LETTER(S)

INSTRUMENT SOCIETY OF AMERICA

(*) WHEN USED EXPLANATION IS SHOWN ADJACENT TO INSTRUMENT SYMBOL.

INSTRUMENT IDENTIFICATION

LOCATION DESIGNATOR

EQUIPMENT DESIGNATOR

ISA FIRST LETTER

INSTRUMENT/LOOP NUMBER

TAG NUMBER: AAA-BBB-XX-YYY

CG

CH

DO3

ES

FAIL

FOR

FR

HA

HOA

HOR

L

LOR

LR

O3

OP

O/C

OL

O/C/A

O/O

O/S/C

O2

pH

REV

RUN

S/S

STR

STP

TURB

UVT

COMBUSTIBLE GAS

CHLORINE

DISSOLVED OZONE

EMERGENCY STOP

FAILURE

FOWARD

FORWARD-REVERSE

HAND-AUTO

HAND-OFF-AUTO

HAND-OFF-REMOTE

LOCAL

LOCAL-OFF-REMOTE

LOCAL-REMOTE

OZONE

OPEN

OPEN-CLOSE

OVERLOAD

OPEN-CLOSE-AUTO

ON-OFF

OPEN-STOP-CLOSE

OXYGEN

pH

JOG-REVERSE

RUNNING

START-STOP

START

STOP

TURBIDITY

UV TRANSMITTANCE

EQUIPMENT TAG NAME STRUCTURE

LINESTYLES AND INTERFACE SYMBOLS

SIGNAL

X

BROKEN SIGNAL LINE

X = SAME SHEET

DESTINATION NO.

INTERFACE FROM

PROCESS EXTERNAL

TO PROJECT

PROCESS

PLC I/O SYMBOLS

AI

AO

DI

DO

INSTRUMENT SYMBOLS

EQUIPMENT IDENTIFIER

MOTOR STARTER SYMBOLS

VFD

MOTOR STARTER

VARIABLE FREQUENCY

DRIVE

RVAT

REDUCED VOLTAGE

AUTO-TRANSFORMER STARTER

CONNECTOR LOCATION

INTERFACE FROM

PROCESS EXTERNAL

TO PROJECT

CONNECTOR LOCATION

GRID P&ID NO.

GRID P&ID NO.

AAA

XX

ZZZ

YYY

AIR COMPRESSOR

AIR-COOLED CHILLER

ACCESS CONTROL PANEL

AIR DRYER

ALUM FEEDER

AIR FILTER

AIR HANDLING UNIT

AIR RECEIVER

ACOUSTIC SILENCER

AUTOMATIC TRANSFER SWITCH

AERATION BLOWER

BATTERY CHARGER

BUTTERFLY VALVE

BYPASS SWITCH

BALL VALVE

COMPRESSOR

CIRCUIT BREAKER

CALIBRATION COLUMN

CONTROL DAMPER

CONDENSER

CHILLER

CONVEYOR

COPPER PATCH PANEL

CONTROL STATION

CONDENSING UNIT

CHECK VALVE

DEHUMIDIFIER

DRIVE / DRIVE MOTOR

DISCONNECT SWITCH

ELECTRIC DUCT HEATER

EXHAUST FAN

ELECTRONIC POWER METER

EMERGENCY PULL SWITCH

EXPANSION TANK

FAN

FAN COIL UNIT

FLOW CONTROL VALVE

FIBER OPTIC PATCH PANEL

GENERATOR

GATE VALVE

WATER

HEAT PUMP

HORN

HOIST

HEATER

HAND VALVE

LIGHTING CONTACTOR

LOCAL CONTROL PANEL

LIMIT SWITCH

MOTOR

MAKE UP AIR UNIT

MOTOR CONTROL CENTER

MAIN CONTROL PANEL

MOTOR OPERATED CONTROL VALVE

MOTORIZED DAMPER

METERING PUMP

AC

ACC

ACP

AD

AF

AFR

AHU

AR

AS

ATS

B

BCH

BFV

BSW

BV

C

CB

CC

CD

CDR

CH

CNV

CPP

CST

CU

CV

DEH

DRV

DS

EDH

EF

EPM

EPS

ET

F

FCU

FCV

FOP

GEN

GV

H20

HP

HRN

HST

HTR

HV

LC

LCP

LS

M

MAU

MCC

MCP

MCV

MD

MP

IDENTIFIER DESCRIPTIONIDENTIFIER (BBB)

MOTOR STARTER

MIXER

NETWORK EQUIPMENT RACK

NETWORK SWITCH

OZONE

OZONE DESTRUCT UNIT

OPERATOR INTERFACE TERMINAL

OPERATOR WORKSTATION

OZONE GENERATOR

OZONE GAS

OZONATED WATER

PUMP

PLANT CONTROL SYSTEM

PULSATION DAMPER

POWER DISTRIBUTION PANEL

POLYMER FEEDER

PHOTOCELL

PROGRAMMABLE LOGIC CONTROLLER

PLUG AND RECEPTACLE

PANELBOARD

PRINTER

PRESSURE REDUCING VALVE

POWER SUPPLY UNIT

PLUG VALVE

AIR RECEIVER

REGULATOR

RESERVOIR

ROTAMETER

SMOKE DETECTOR

SUPPLY FAN

SLIDE GATE

SKID

SAMPLER

SUMP PUMP

SURGE RELIEF VALVE

COMBINATION STARTER

STROBE

STOP GATE

STRAINER

SOLENOID VALVE

SERVER

SWITCHBOARD

SWITCHGEAR

THERMOSTAT

TEMPERATURE CONTROL PANEL

TANK

TELESCOPING VALVE

UNITERRUPTIBLE POWER SUPPLY

VALVE

VAPORIZER

VARIABLE FREQUENCY DRIVE

WATER HEATER

TRANSFORMER

MS

MXR

NER

NSW

O3

ODU

OIT

OWS

OZG

OZN

OZW

P

PCS

PD

PDP

PF

PHC

PLC

PLG

PNL

PRNT

PRV

PSU

PV

RCV

REG

RES

RO

SD

SF

SG

SKD

SMP

SP

SRV

ST

STB

STG

STR

SV

SVR

SWBD

SWG

T

TCP

TNK

TV

UPS

V

VAP

VFD

WH

XF

IDENTIFIER DESCRIPTIONIDENTIFIER (BBB)

FACILITY IDENTIFIER (WHEN APPLICABLE)

FACILITY AREA OR SYSTEM

IDENTIFIER (SEE TABLE BELOW)

EQUIPMENT/INSTRUMENT

IDENTIFIER (SEE TABLE BELOW)

LOOP NUMBER

UNIT NUMBER

UNIT MODIFER (WHEN APPLICABLE)

ID - AAA - BBB - XX Y Z

XX = INSTRUMENT TYPE

YYY = NUMBER

ZZZ = DESCRIPTOR:

M MAGNETIC FLOW METER

LOCALLY MOUNTED FIELD

INSTRUMENT

MOUNTED ON PANEL FRONT

MOUNTED INSIDE PANEL

ULTRASONIC

RADAR

FLOAT LEVEL SWITCH

FACILITY AREA OR SYSTEM IDENTIFIER

IDENTIFIER (ID) IDENTIFIER DESCRIPTION

P1

P2

P12

TREATMENT PLANT NO. 1

TREATMENT PLANT NO. 2

TREATMENT PLANT NO. 1 AND NO. 2 (COMMON)

FACILITY IDENTIFIER

NOTES:

1. THIS LEGEND IS TAKEN FROM A STANDARD PROCESS LEGEND AND NOT ALL ITEMS

OR EQUIPMENT AS DESIGNATED HEREON ARE USED ON THIS PROJECT.

2. SOME ABBREVIATIONS MAY NOT BE USED.

OIT

ADMINISTRATION BUILDING

ALUM FLASH MIX

CHEMICAL BUILDING

CARBON DIOXIDE SYSTEM

COOLING WATER SYSTEM

FILTERS

GASEOUS OXYGEN

HIGH/LOW BUILDING

HIGH SERVICE PUMP STATION

LIME BUILDING

IDENTIFIER DESCRIPTIONIDENTIFIER (AAA)

LIQUID OXYGEN SYSTEM

METERING HOUSE

POST OZONE CONTACT BASIN

OZONE BUILDING

OZONE NITROGEN BOOST

PRE-OZONE CONTACT BASIN

SEDIMENTATION BASIN

SWITCHGEAR BUILDING

YARD PIPING

LOX

MHS

OCB

OZB

OZN

POCB

SED

SWGR

YD

IDENTIFIER DESCRIPTIONIDENTIFIER (AAA)

SERVICE DESCRIPTION

ORIGIN/DESTINATION

SERVICE DESCRIPTION

ORIGIN/DESTINATION

ANALOG INPUT TO PLC

ANALOG OUTPUT

FROM PLC

DIGITAL INPUT TO PLC

DIGITAL OUTPUT

FROM PLC

OPERATOR

INTERFACE TERMINAL

PROCESS LINE

EXISTING PROCESS LINE

ELECTRICAL SIGNAL (ANALOG)

ELECTRICAL SIGNAL (DISCRETE) (0.5)

ELECTRICAL SIGNAL (POWER)

SOFTWARE OR DATA LINK (1.75)

SPECIAL SIGNAL CABLE (1.5)

PNEUMATIC SIGNAL

CABINET BOUNDARY

EQUIPMENT OR SKID BOUNDARY

FUTURE EQUIPMENT BOUNDARY

DIRECTION OF FLOW

SIGNAL CONNECTION

CROSSOVER - NO CONNECTION

THERMAL MASS FLOW METERT

.

.

ROTAMETER

ADM

AFM

CHB

CO2

CW

FLT

GOX

HLB

HPS

LIM

YYY

ZZZ

XX

AAAAAA

XX

ZZZ

YYY

ORFICE PLATE FLOW METER

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

FEBRUARY 02, 2017 M. CHARRETTE

R. DRAIN T. McGOWN

AMISS WTP IMPROVEMENTS

PID LEGEND, ABBREVIATIONS AND

GENERAL NOTES 2

96191 E14003

DI002 D

96191_DI002.dwg

2018

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

PRELIMINARY - NOT

FOR CONSTRUCTION

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400

BONTONASSOCIATES

CIVIL ENGINEERING ENVIRONMENTAL PLANNING

TM01/05/18 RD ISSUED FOR 30%

OWNERS REVIEW

A

TM02/12/18 RD ISSUED FOR

PRESELECTION

B

TM05/31/18 RD ISSUED FOR 60%

OWNERS REVIEW

C

ISSUED FOR 90%

OWNERS REVIEW

TM12/03/18 RDD

Page 4: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

SCREW PUMP

PROGRESSIVE CAVITY

PUMP

VERTICAL TURBINE

PUMP

HORIZONTAL

CENTRIFUGAL PUMP

POSITIVE

DISPLACEMENT PUMP

LIQUID RING

VACUUM PUMP

VERTICAL

INLINE PUMP

CENTRIFUGAL

SUMP PUMP

POSITIVE DISPLACEMENT

BLOWER

CENTRIFUGAL COMPRESSOR

RECIPROCATING COMPRESSOR

CENTRIFUGAL BLOWER

TURBINE DRIVER

AGITATOR/MIXER

DRIVERS

COMPRESSORS & BLOWERSPUMPS SELF-ACTUATED DEVICES

MISCELLANEOUS

DIESEL ENGINE

TYPICAL TEMPERATURE LOOP WITH VALVE POSITIONER

TYPICAL FLOW LOOP WITH SEPARATE I/P

TYPICAL PUMP MOTOR CONTROLS

HOA

I/P

SHOWN ON P&ID

HS

SHOWN ON P&ID

FC

TT

TC

O

SHOWN ON P&ID

FC

ZS

C

IAS

HS

O/C

SHOWN ON P&ID

L

FT

FC

H

FC FY

IMPLIED

HS

S/S

EL HS

I

TV

IMPLIED

FC

TE TW

TT

S/S

HS

HOA

TC

IMPLIED

FC

HV

ZSC ZSO

HY

IAS

TYPICAL VALVE DETAIL

HS ZL

C

O

FE

IMPLIED

FV

FT

L

FC

FC

H

FY

I/P

MOTOR

SUBMERSIBLE PUMP

S S

PRESSURE AND VACUUM

RELIEF VALVE OR

CONSERVATION VENT

SAFETY HEAD FOR

VACUUM RELIEF

(EXPLOSION PANEL)

VACUUM RELIEF

VALVE

PRESSURE RELIEF

SAFETY HEAD FOR

(EXPLOSION PANEL)

PRESSURE RELIEF

(SELF-CONTAINED)

PRESSURE REDUCING

REGULATOR

REGULATOR

(SELF-CONTAINED)

REGULATOR

W/ EXTERNAL TAP

W/ EXTERNAL TAP

REGULATOR

PRESSURE REDUCING

BACK PRESSURE

BACK PRESSURE

REDUCING REGULATOR

FILLED SYSTEM TYPE

DIFFERENTIAL PRESSURE

TEMPERATURE REGULATOR

(USE APPROPRIATE

PILOT OPERATED

RELIEF VALVE SYMBOL)

RELIEF VALVE WITH

REMOTE SENSOR

RUPTURE DISC OR

RUPTURE DISC OR

OR SAFETY VALVE

P

LEVEL OR D/P INSTRUMENT

(PDI, PDT, LC, LG, LT, LS)

PIPING INST.

PIPING INST.

ORIFICE FLANGE - MOUNTED FLOW INSTRUMENT

VALVE TYPE

PER LINE CLASS.

VALVE SIZE PER

INSTRUMENT

SPECIFICATION

FIELD MOUNTED PRESSURE INSTRUMENT

(PI, PT, PS)

SHOWN ON P&ID

SHOWN ON P&ID

IMPLIED

PIPING

INST.

(FI, FT)

IMPLIED

PIPING

INST.

VALVE TYPE

PER LINE CLASS.

VALVE SIZE PER

INSTRUMENT

SPECIFICATION

VALVE TYPE

PER LINE CLASS.

VALVE SIZE PER

INSTRUMENT

SPECIFICATION

SHOWN ON P&ID IMPLIED

NOTES:

1. THIS LEGEND IS TAKEN FROM A STANDARD

PROCESS LEGEND AND NOT ALL ITEMS

OR EQUIPMENT AS DESIGNATED HEREON

ARE USED ON THIS PROJECT.

2. SOME ABBREVIATIONS MAY NOT BE USED.

CHEMICAL METERING

PUMP

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

FEBRUARY 02, 2017 M. CHARRETTE

R. DRAIN T. McGOWN

AMISS WTP IMPROVEMENTS

PID LEGEND, ABBREVIATIONS AND

GENERAL NOTES 3

96191 E14003

DI003 D

96191_DI003.dwg

2018

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

PRELIMINARY - NOT

FOR CONSTRUCTION

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400

BONTONASSOCIATES

CIVIL ENGINEERING ENVIRONMENTAL PLANNING

TM01/05/18 RD ISSUED FOR 30%

OWNERS REVIEW

A

TM02/12/18 RD ISSUED FOR

PRESELECTION

B

TM05/31/18 RD ISSUED FOR 60%

OWNERS REVIEW

C

ISSUED FOR 90%

OWNERS REVIEW

TM12/03/18 RDD

Page 5: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

AMMONIA

PRE-OZONE

CONTACT BASIN

RM

RM

RM

POST-OZONE

CONTACT BASIN

NO. 2

WTP 2

FLOC

BASINS

WTP 2

SED

BASINS

METER

HOUSE

FLASH MIX

WTP 2E

FLOC

BASIN

10

FLASH MIX

FLASH MIX

PACL

WTP 2E

SED

BASINS

WTP 2E

FLOC

BASIN

11

PACL

PACL

PLANT 2 FILTER

BUILDING

PACL

POLYMER

ALUM

SODA ASH

SODIUM THIOSULFATE

CHLORINE

SODIUM THIOSULFATE

ALUM

ALUM

ALUM

POLYMER

ALUM

POLYMER

ALUM

42" SETTLED

WATER BYPASS

POLYMER

ALUM

48" OZONATED RAW WATER

30" OZONATED RAW WATER

48" RAW WATER BYPASS

60" SETTLED WATER

60" SETTLED WATER

CO2

CO2

CAUSTIC

CAUSTIC

42" OZONATED SETTLED WATER

42" O

ZO

NA

TE

D R

AW

W

AT

ER

TO DISTRIBUTION

TO DISTRIBUTION

TO DISTRIBUTION

CAUSTIC

CHLORINE

FLUORIDE

OZONE

CAUSTIC

CHLORINE

OZONE

CHLORINE

AMMONIA

FLUORIDE

OZONE

CHLORINE

CAUSTIC

CAUSTIC

M M M

CHLORINE

DIOXIDE

M

M

M

*

*

*

*

*

*

60" SETTLED

WATER BYPASS

NOTES:

1. ALL CHEMICAL FEED DENOTED WITH AN ASTERISK " " IS

TO BE REMOVED. REFER TO SPECIFICATIONS FOR

TIMING OF REMOVAL.

2. PORTIONS OF THE WORK ARE NOT SHOWN ON THIS

FLOW DIAGRAM. REFER TO PLANS AND SPECIFICATIONS.

*

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

DECEMBER 15, 2017 C. VERRETT

C. CABALLERO A. BEESON

AMISS WTP IMPROVEMENTS

PROCESS FLOW DIAGRAM

96191 E14003

DI004 C

96191_DI004.dwg

2018

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

PRELIMINARY - NOT

FOR CONSTRUCTION

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400

BONTONASSOCIATES

CIVIL ENGINEERING ENVIRONMENTAL PLANNING

RM

RM

POST-OZONE

CONTACT BASIN

NO. 1

WTP 1

FLOC

BASINS

WTP 1

SED

BASINS

LOW SERVICE

PUMP STATION

PLANT 1 FILTER

BUILDING

CLEARWELL

NO.1

(5 MG)

42" OZONATED RAW WATER

60

" R

AW

W

AT

ER

B

YP

AS

S

48

" R

AW

W

AT

ER

B

YP

AS

S

FM

42" SETTLED WATER

42

" O

ZO

NA

TE

D S

ET

TL

ED

W

AT

ER

60" FINISHED WATER

36

" F

IN

IS

HE

D W

AT

ER

CHLORINE DIOXIDE

30" OZONATED RAW WATER

CLEARWELL

NO.2

(5 MG)

CLEARWELL

NO.3

(5 MG)

HSPS NO. 3

HSPS NO. 1

HSPS NO. 2

CHLORINE

PAC

AB01/05/18 CC ISSUED FOR 30%

OWNER REVIEW

AB05/31/18 CC ISSUED FOR 60%

OWNER REVIEW

B

A

ISSUED FOR 90%

OWNERS REVIEW

AB12/03/18 CCC

Page 6: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

GENERAL NOTES:

1. NOT ALL VALVES, INSTRUMENTS, PIPING, ETC. SHOWN.

REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

SUPPLIERS SHALL PROVIDE COMPLETE AND WORKING

SYSTEMS. FINAL SIZING TO BE DETERMINED BY SUPPLIER

UNLESS OTHERWISE NOTED.

2. ALL EQUIPMENT INDICATED WITH AN ASTERISK "*" SHALL BE

PROVIDED BY OZONE SYSTEM SUPPLIER (OSS).

3. INSTRUMENTATION AND VALVING FOR LOX TANK NOT

SHOWN ON P&ID.

4. REFER TO LOX EQUIPMENT SPECIFICATION FOR DETAILS

AND CONTROLS.

EXTERIOR INTERIOR

OZONE BUILDING

F1 DI030

OZONE GENERATOR

NO. 2

GOX

PI

203

GOX

OXYGEN FILTER SKID *

P12-GOX-SKD-200

PDIT

201

GOX

PIT

201

GOX

TE

201

GOX

TIT

201

GOX

PI

201

LOX

AE

301

GOX

F1 DI029

OZONE GENERATOR

NO. 1

GOX

EMERGENCY

FILL

CONNECTION

LOX STORAGE TANK

P12-LOX-TNK-100

9,000 GAL

FUTURE

CONNECTION

FUTURE

CONNECTION

VAPORIZER NO. 1

P12-LOX-VAP-210

AIT

301

GOX

VAPORIZER NO. 2

P12-LOX-VAP-220

PI

202

GOX

OXYGEN

FILTER

*

FUTURE

CONNECTION

FILL

CONNECTION

LOX SYSTEM

SUPPLIER

4" SST

4" SST

3" SST

3" SST

3" SST

3/4" SST

G1 DI031

OZONE GENERATOR

NO. 3

GOX

M

P12-LOX-MCV-220

M

P12-LOX-MCV-210

M

P12-LOX-MCV-201

FIT

201

GOX

E13DI028

NITROGEN BOOST SKID

COMPRESSED AIR

FC

210

LOX

FC

220

LOX

FC

201

LOX

AI

P

1

2

-

G

O

X

-

A

I

T

-

A

I

-

3

0

1

AI

P

1

2

-

G

O

X

-

F

I

T

-

F

I

-

2

0

1

AI

P

1

2

-

G

O

X

-

P

D

I

T

-

P

D

I

-

2

0

1

AI

P

1

2

-

G

O

X

-

T

I

T

-

T

I

-

2

0

1

AI

P

1

2

-

G

O

X

-

P

I

T

-

P

I

-

2

0

1

VAPORIZER SWITCHING

MANIFOLD

LOX STORAGE TANK

P12-LOX-TNK-___

9,000 GAL

LIT

.

.

LIT

.

.

101

184

3" SST

*

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

FEBRUARY 02, 2017 M. CHARRETTE

R. DRAIN T. McGOWN

AMISS WTP IMPROVEMENTS

OXYGEN SUPPLY SYSTEM PID

96191 E14003

DI027 D

96191_DI027.dwg

2018

PRELIMINARY - NOT

FOR CONSTRUCTION

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400

BONTONASSOCIATES

CIVIL ENGINEERING ENVIRONMENTAL PLANNING

TM01/05/18 RD ISSUED FOR 30%

OWNERS REVIEW

A

TM02/12/18 RD ISSUED FOR

PRESELECTION

B

TM05/31/18 RD ISSUED FOR 60%

OWNERS REVIEW

C

P12-OZB-MOCP-300

TM12/03/18 RD ISSUED FOR 90%

OWNERS REVIEW

D

DO

P

1

2

-

G

O

X

-

M

C

V

-

X

S

-

2

0

1

DI

P

1

2

-

G

O

X

-

M

C

V

-

Z

S

C

-

2

0

1

DI

P

1

2

-

G

O

X

-

M

C

V

-

Z

S

O

-

2

0

1

Page 7: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

PSL

400

OZN

PSH

400

OZN

PIT

400

OZN

T

AE

401

DEWOZN

PIT

401

OZN

AIT

401

DEWOZN

PDIT

411

OZN

PDIT

412

OZN

PDIT

422

OZN

PDIT

421

OZN

FC

401

OZN

FILTER

P12-OZN-FLT-411

FILTER

P12-OZN-FLT-412

FILTER

P12-OZN-FLT-422

FILTER

P12-OZN-FLT-421

AIR

FILTER

P12-OZN-FLT-410

COMPRESSOR

P12-OZN-C-410

AIR

FILTER

P12-OZN-FLT-420

COMPRESSOR

P12-OZN-C-420

NITROGEN BOOST SKID *

P12-OZN-SKD-400

AIR RECEIVER

P12-OZN-AR-400

3/4" SST

S

P12-OZN-MSV-400

FIT

401

OZN

FE

401

OZN

M

P12-OZN-MCV-401

H13 DI027

OXYGEN SUPPLY

SYSTEM

COMPRESSED AIR

FC

400

OZN

DI

P

1

2

-

O

Z

N

-

C

-

M

N

-

4

1

0

DI

P

1

2

-

O

Z

N

-

C

-

Y

A

-

4

1

0

DI

P

1

2

-

O

Z

N

-

C

-

M

N

-

4

2

0

DI

P

1

2

-

O

Z

N

-

C

-

Y

A

-

4

2

0

PSV

401

OZN

P12-OZN-MS-410

P12-OZN-MS-420

NITROGEN BOOST LOCAL CONTROL PANEL

P12-OZN-LCP-400

DI

P

1

2

-

O

Z

N

-

A

R

-

P

S

L

-

4

0

0

1" PVC

GENERAL NOTES:

1. NOT ALL VALVES, INSTRUMENTS, PIPING, ETC. SHOWN.

REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

SUPPLIERS SHALL PROVIDE COMPLETE AND WORKING

SYSTEMS. FINAL SIZING TO BE DETERMINED BY SUPPLIER

UNLESS OTHERWISE NOTED.

2. ALL EQUIPMENT INDICATED WITH AN ASTERISK "*" SHALL BE

PROVIDED BY OZONE SYSTEM SUPPLIER (OSS).

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

FEBRUARY 02, 2017 M. CHARRETTE

R. DRAIN T. McGOWN

AMISS WTP IMPROVEMENTS

NITROGEN BOOST SYSTEM

96191 E14003

DI028 D

96191_DI028.dwg

2018

PRELIMINARY - NOT

FOR CONSTRUCTION

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400

BONTONASSOCIATES

CIVIL ENGINEERING ENVIRONMENTAL PLANNING

TM01/05/18 RD ISSUED FOR 30%

OWNERS REVIEW

A

TM02/12/18 RD ISSUED FOR

PRESELECTION

B

TM05/31/18 RD ISSUED FOR 60%

OWNERS REVIEW

C

P12-OZB-MOCP-300

TM12/03/18 RD ISSUED FOR 90%

OWNERS REVIEW

D

Page 8: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

OZONE GENERATION SYSTEM NO. 1 *

P12-OZB-SKD-310

(NOTE 3)

E1 DI032

CHILLERS

CHILLED WATER

RETURN

T

PIT

211

OZB

PI

511

CW

PSH

211

OZB

PSL

211

OZB

AE

311

O3OZB

TE

211

OZB

TIT

211

OZB

TE

511

CW

PI

311

OZB

AIT

311

O3OZB

TE

311

OZB

TIT

311

OZB

TE

512

CW

TSH

512

CW

F13 DI031

OZONE HEADER

OZONE GAS

M

PI

512

CW

FE

512

TI

512

CW

A

*

(NOTE 4)

TI

511

CW

1" SST1" SST

3" SST

4" SST

1 1/2" SST

(NOTE 3)

1 1/2" SST

1" PVC 1" PVC

4" SST

3" SST

1" PVC

G13 DI033

CHILLERS

CHILLED WATER

SUPPLY

FE

211

OZB

FIT

211

OZB

M

P12-OZB-MCV-211

M

P12-OZB-MCV-511

1 1/2" SST

(NOTE 3)

1 1/2" SST

PSU NO. 1

P12-OZB-PSU-310

(NOTE 5)

OZONE

GENERATOR NO. 1

P12-OZB-OZG-310

(NOTE 5)

M

P12-OZB-MCV-311

FE

512

CW

FIT

512

CW

WALL-MOUNTED

MONITOR

AMBIENT

AIR

WALL-MOUNTED

MONITOR

AMBIENT

AIR

AIT

301

O3OZB

AIT

302

O2OZB

AE

301

O3OZB

AE

302

O2OZB

M

P12-CW-MCV-512

FSL

512

CW

F13 DI027

OXYGEN SUPPLY

GOX

**

FC

511

CW

*

FC

211

OZB

*

FC

311

OZB

*

FC

512

CW

*

OZONE GENERATOR LOCAL CONTROL PANEL

P12-OZB-LCP-310

DO

P

1

2

-

O

Z

B

-

M

C

V

-

X

S

-

2

1

1

DI

P

1

2

-

O

Z

B

-

M

C

V

-

Z

S

C

-

2

1

1

DI

P

1

2

-

O

Z

B

-

M

C

V

-

Z

S

O

-

2

1

1

DO

P

1

2

-

O

Z

B

-

M

C

V

-

X

S

-

3

1

1

DI

P

1

2

-

O

Z

B

-

M

C

V

-

Z

S

C

-

3

1

1

DI

P

1

2

-

O

Z

B

-

M

C

V

-

Z

S

O

-

3

1

1

DO

P

1

2

-

C

W

-

M

C

V

-

X

S

-

5

1

1

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

C

-

5

1

1

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

O

-

5

1

1

DO

P

1

2

-

C

W

-

M

C

V

-

X

S

-

5

1

2

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

C

-

5

1

2

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

O

-

5

1

2

DI

P

1

2

-

O

Z

B

-

P

S

L

-

P

A

L

-

2

1

1

DI

P

1

2

-

O

Z

B

-

P

S

H

-

P

S

H

-

2

1

1

DI

P

1

2

-

C

W

-

F

S

L

-

F

A

L

-

5

1

2

DI

P

1

2

-

C

W

-

T

S

H

-

T

A

H

-

5

1

2

AI

P

1

2

-

O

Z

B

-

P

I

T

-

P

I

-

2

1

1

AI

P

1

2

-

O

Z

B

-

F

I

T

-

F

I

-

2

1

1

AI

P

1

2

-

O

Z

B

-

T

I

T

-

T

I

-

2

1

1

AI

P

1

2

-

O

Z

B

-

T

I

T

-

T

I

-

3

1

1

AI

P

1

2

-

O

Z

B

-

A

I

T

-

A

I

-

3

1

1

AI

P

1

2

-

C

W

-

F

I

T

-

F

I

-

5

1

2

AI

P

1

2

-

O

Z

B

-

A

I

T

-

A

I

-

3

0

1

AI

P

1

2

-

O

Z

B

-

A

I

T

-

A

I

-

3

0

2

D13 DI030

VENT HEADER

VENT

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

NOVEMBER 21, 2017 C. STILL

R. DRAIN T. McGOWN

AMISS WTP IMPROVEMENTS

OZONE GENERATION SYSTEM NO. 1

96191 E14003

DI029 C

96191_DI029.dwg

2018

PRELIMINARY - NOT

FOR CONSTRUCTION

GENERAL NOTES:

1. NOT ALL VALVES, INSTRUMENTS, PIPING, ETC. SHOWN. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

SUPPLIERS SHALL PROVIDE COMPLETE AND WORKING SYSTEMS. FINAL SIZING TO BE DETERMINED BY SUPPLIER

UNLESS OTHERWISE NOTED.

2. ALL EQUIPMENT INDICATED WITH AN ASTERISK "*" SHALL BE PROVIDED BY OZONE SYSTEM SUPPLIER (OSS).

3. SKIDS TO BE PROVIDED BY OZONE SYSTEM SUPPLIER (OSS). SOME PIPING, INCLUDING REFRIGERANT PIPING, TO BE

PROVIDED BY CONTRACTOR. CONTRACTOR SHALL COORDINATE WITH OSS TO DETERMINE LIMIT OF SCOPE.

4. AIR RELEASE VALVE TO BE INSTALLED BY CONTRACTOR AT HIGH POINT OF CHILLED WATER LOOP.

5. THE OZONE GENERATOR SKID AND POWER SUPPLY UNITS MAY BE PROVIDED AS SEPARATE SKID PACKAGES.

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400

BONTONASSOCIATES

CIVIL ENGINEERING ENVIRONMENTAL PLANNING

TM01/05/18 RD ISSUED FOR 30%

OWNERS REVIEW

A

TM02/12/18 RD ISSUED FOR

PRESELECTION

B

TM05/31/18 RD ISSUED FOR 60%

OWNERS REVIEW

C

P12-OZB-MOCP-300

TM12/03/18 RD ISSUED FOR 90%

OWNERS REVIEW

D

Page 9: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

A

*

F13 DI031

OZONE HEADER

OZONE GAS

G13 DI033

CHILLERS

CHILLED WATER

SUPPLY

(NOTE 4)

3" SST

4" SST

3" SST

4" SST

1" SST 1" SST

1" PVC 1" PVC

1" PVC

1 1/2" SST

(NOTE 3)

1 1/2" SST

OZONE GENERATION SYSTEM NO. 2 *

P12-OZB-SKD-320

(NOTE 3)

T

PIT

221

?OZB

PI

521

?CW

PSH

221

?OZB

PSL

221

?OZB

AE

311

O3OZB

TE

221

?OZB

TIT

221

?OZB

TE

521

?CW

PI

321

?OZB

AIT

311

O3OZB

TE

321

?OZB

TIT

321

?OZB

TE

522

?CW

TSH

522

?CW

M

PI

522

?CW

FE

512

TI

522

?CW

TI

521

?CW

FE

221

?OZB

FIT

221

?OZB

1 1/2" SST

(NOTE 3)

1 1/2" SST

PSU NO. 2

P12-OZB-PSU-320

(NOTE 5)

OZONE

GENERATOR NO. 2

P12-OZB-OZG-320

(NOTE 5)

FE

522

?CW

FIT

522

?CW

WALL-MOUNTED

MONITOR

AMBIENT

AIR

WALL-MOUNTED

MONITOR

AMBIENT

AIR

AIT

303

O3OZB

AIT

304

O2OZB

AE

303

O3OZB

AE

304

O2OZB

M

P12-OZB-MCV-521

M

P12-OZB-MCV-221

M

P12-OZB-MCV-321

M

P12-CW-MCV-522

F13 DI027

OXYGEN SUPPLY

GOX

FC

521

?CW

*

**

FC

221

?OZB

*

FC

321

?OZB

*

FC

522

?CW

*

FSL

522

?CW

OZONE GENERATOR LOCAL CONTROL PANEL

P12-OZB-LCP-320

DO

P

1

2

-

O

Z

B

-

M

C

V

-

X

S

-

2

2

1

DI

P

1

2

-

O

Z

B

-

M

C

V

-

Z

S

C

-

2

2

1

DI

P

1

2

-

O

Z

B

-

M

C

V

-

Z

S

O

-

2

2

1

DO

P

1

2

-

O

Z

B

-

M

C

V

-

X

S

-

3

2

1

DI

P

1

2

-

O

Z

B

-

M

C

V

-

Z

S

C

-

3

2

1

DI

P

1

2

-

O

Z

B

-

M

C

V

-

Z

S

O

-

3

2

1

DO

P

1

2

-

C

W

-

M

C

V

-

X

S

-

5

2

1

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

C

-

5

2

1

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

O

-

5

2

1

DO

P

1

2

-

C

W

-

M

C

V

-

X

S

-

5

2

2

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

C

-

5

2

2

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

O

-

5

2

2

DI

P

1

2

-

O

Z

B

-

P

S

L

-

P

A

L

-

2

2

1

DI

P

1

2

-

O

Z

B

-

P

S

H

-

P

S

H

-

2

2

1

DI

P

1

2

-

C

W

-

F

S

L

-

F

A

L

-

5

2

2

DI

P

1

2

-

C

W

-

T

S

H

-

T

A

H

-

5

2

2

AI

P

1

2

-

O

Z

B

-

P

I

T

-

P

I

-

2

2

1

AI

P

1

2

-

O

Z

B

-

F

I

T

-

F

I

-

2

2

1

AI

P

1

2

-

O

Z

B

-

T

I

T

-

T

I

-

2

2

1

AI

P

1

2

-

O

Z

B

-

T

I

T

-

T

I

-

3

2

1

AI

P

1

2

-

O

Z

B

-

A

I

T

-

A

I

-

3

2

1

AI

P

1

2

-

C

W

-

F

I

T

-

F

I

-

5

2

2

AI

P

1

2

-

O

Z

B

-

A

I

T

-

A

I

-

3

0

3

AI

P

1

2

-

O

Z

B

-

A

I

T

-

A

I

-

3

0

4

F1 DI032

CHILLERS

CHILLED WATER

RETURN

C13DI029

VENT

OZONE GENERATOR

NO. 1

D1DI031

VENT

OZONE GENERATOR

NO. 2

OUTSIDE BUILDING

VENT

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

NOVEMBER 21, 2017 C. STILL

R. DRAIN T. McGOWN

AMISS WTP IMPROVEMENTS

OZONE GENERATION SYSTEM NO. 2

96191 E14003

DI030 C

96191_DI030.dwg

2018

PRELIMINARY - NOT

FOR CONSTRUCTION

GENERAL NOTES:

1. NOT ALL VALVES, INSTRUMENTS, PIPING, ETC. SHOWN. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

SUPPLIERS SHALL PROVIDE COMPLETE AND WORKING SYSTEMS. FINAL SIZING TO BE DETERMINED BY SUPPLIER UNLESS

OTHERWISE NOTED.

2. ALL EQUIPMENT INDICATED WITH AN ASTERISK "*" SHALL BE PROVIDED BY OZONE SYSTEM SUPPLIER (OSS).

3. SKIDS TO BE PROVIDED BY OZONE SYSTEM SUPPLIER (OSS). SOME PIPING, INCLUDING REFRIGERANT PIPING, TO BE

PROVIDED BY CONTRACTOR. CONTRACTOR SHALL COORDINATE WITH OSS TO DETERMINE LIMIT OF SCOPE.

4. AIR RELEASE VALVE TO BE SUPPLIED BY OSS AND INSTALLED BY CONTRACTOR AT HIGH POINT OF CHILLED WATER LOOP.

5. THE OZONE GENERATOR SKID AND POWER SUPPLY UNITS MAY BE PROVIDED AS SEPARATE SKID PACKAGES.

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400

BONTONASSOCIATES

CIVIL ENGINEERING ENVIRONMENTAL PLANNING

TM01/05/18 RD ISSUED FOR 30%

OWNERS REVIEW

A

TM02/12/18 RD ISSUED FOR

PRESELECTION

B

TM05/31/18 RD ISSUED FOR 60%

OWNERS REVIEW

C

P12-OZB-MOCP-300

Page 10: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

EXTERIORINTERIOR OZONE

BUILDING

. .

A

*

(NOTE 4)

E13DI030

OZONE GAS

OZONE GENERATOR

NO. 2

E13DI029

OZONE GAS

OZONE GENERATOR

NO. 1

D1 DI036

WTP 2 CONTACT BASIN

OZONE GAS

D1 DI035

WTP 1 CONTACT BASIN

OZONE GAS

PI

302

OZB

PI

301

OZB

3" SST

FUTURE

CONNECTION

1" SST 1" SST

1 1/2" SST

(NOTE 3)

1 1/2" SST

1" PVC 1" PVC

1" PVC

3" SST

4" SST

3" SST

6" SST

6" SST

3" SST

3" SST

3" SST

4" SST

3" SST

*

*

*

F1 DI032

CHILLERS

CHILLED WATER

RETURN

D1 DI034

PRE-OZONE CONTACT

BASIN

OZONE GAS

H13 DI033

CHILLERS

CHILLED WATER

SUPPLY

OZONE GENERATION SYSTEM NO. 3 *

P12-OZB-SKD-330

(NOTE 3)

M

P12-OZB-MCV-531

M

P12-OZB-MCV-231

T

PIT

231

OZB

PI

531

CW

PSH

231

OZB

PSL

231

OZB

AE

331

O3OZB

TE

231

OZB

TIT

231

OZB

TE

531

CW

M

P12-OZB-MCV-331

PI

331

OZB

AIT

331

O3OZB

TE

331

OZB

TIT

331

OZB

TE

532

CW

TSH

532

CW

M

M

P12-CW-MCV-532

PI

532

CW

FE

532

TI

531

CW

FE

231

OZB

FIT

231

OZB

1 1/2" SST

(NOTE 3)

1 1/2" SST

PSU NO. 3

P12-OZB-PSU-330

(NOTE 5)

OZONE

GENERATOR NO. 3

P12-OZB-OZG-330

(NOTE 5)

FE

532

CW

FIT

532

CWTI

532

CW

FSL

532

CW

G13 DI027

OXYGEN SUPPLY

GOX

* *

*

*

*

FC

231

OZB

*

FC

531

CW

*

FC

331

OZB

*

FC

532

CW

*

WALL-MOUNTED

MONITOR

AMBIENT

AIR

WALL-MOUNTED

MONITOR

AMBIENT

AIR

AIT

305

O3OZB

AIT

306

O2OZB

AE

305

O3OZB

AE

306

O2OZB

**

OZONE GENERATOR LOCAL CONTROL PANEL

P12-OZB-LCP-330

DO

P

1

2

-

O

Z

B

-

M

C

V

-

X

S

-

2

3

1

DI

P

1

2

-

O

Z

B

-

M

C

V

-

Z

S

C

-

2

3

1

DI

P

1

2

-

O

Z

B

-

M

C

V

-

Z

S

O

-

2

3

1

DO

P

1

2

-

O

Z

B

-

M

C

V

-

X

S

-

3

3

1

DI

P

1

2

-

O

Z

B

-

M

C

V

-

Z

S

C

-

3

3

1

DI

P

1

2

-

O

Z

B

-

M

C

V

-

Z

S

O

-

3

3

1

DO

P

1

2

-

C

W

-

M

C

V

-

X

S

-

5

3

1

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

C

-

5

3

1

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

O

-

5

3

1

DO

P

1

2

-

C

W

-

M

C

V

-

X

S

-

5

3

2

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

C

-

5

3

2

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

O

-

5

3

2

DI

P

1

2

-

O

Z

B

-

P

S

L

-

P

A

L

-

2

3

1

DI

P

1

2

-

O

Z

B

-

P

S

H

-

P

S

H

-

2

3

1

DI

P

1

2

-

C

W

-

F

S

L

-

F

A

L

-

5

3

2

DI

P

1

2

-

C

W

-

T

S

H

-

T

A

H

-

5

3

2

AI

P

1

2

-

O

Z

B

-

P

I

T

-

P

I

-

2

3

1

AI

P

1

2

-

O

Z

B

-

F

I

T

-

F

I

-

2

3

1

AI

P

1

2

-

O

Z

B

-

T

I

T

-

T

I

-

2

3

1

AI

P

1

2

-

O

Z

B

-

T

I

T

-

T

I

-

3

3

1

AI

P

1

2

-

O

Z

B

-

A

I

T

-

A

I

-

3

3

1

AI

P

1

2

-

C

W

-

F

I

T

-

F

I

-

5

3

2

AI

P

1

2

-

O

Z

B

-

A

I

T

-

A

I

-

3

0

1

AI

P

1

2

-

O

Z

B

-

A

I

T

-

A

I

-

3

0

2

D13DI030

VENT HEADER

VENT

102104 103

106

105

107

108

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

NOVEMBER 21, 2017 C. STILL

R. DRAIN T. McGOWN

AMISS WTP IMPROVEMENTS

OZONE GENERATION SYSTEMS NO. 3

96191 E14003

DI031 D

96191_DI031.dwg

2018

PRELIMINARY - NOT

FOR CONSTRUCTION

GENERAL NOTES:

1. NOT ALL VALVES, INSTRUMENTS, PIPING, ETC. SHOWN. REFER TO SPECIFICATIONS FOR ADDITIONAL

INFORMATION. SUPPLIERS SHALL PROVIDE COMPLETE AND WORKING SYSTEMS. FINAL SIZING TO BE

DETERMINED BY SUPPLIER UNLESS OTHERWISE NOTED.

2. ALL EQUIPMENT INDICATED WITH AN ASTERISK "*" SHALL BE PROVIDED BY OZONE SYSTEM SUPPLIER (OSS).

3. SKIDS TO BE PROVIDED BY OZONE SYSTEM SUPPLIER (OSS). SOME PIPING, INCLUDING REFRIGERANT PIPING,

TO BE PROVIDED BY CONTRACTOR. CONTRACTOR SHALL COORDINATE WITH OSS TO DETERMINE LIMIT OF

SCOPE.

4. AIR RELEASE VALVE TO BE SUPPLIED BY OSS AND INSTALLED BY CONTRACTOR AT HIGH POINT OF CHILLED

WATER LOOP.

5. THE OZONE GENERATOR SKID AND POWER SUPPLY UNITS MAY BE PROVIDED AS SEPARATE SKID PACKAGES.

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400

BONTONASSOCIATES

CIVIL ENGINEERING ENVIRONMENTAL PLANNING

TM01/05/18 RD ISSUED FOR 30%

OWNERS REVIEW

A

TM02/12/18 RD ISSUED FOR

PRESELECTION

B

TM05/31/18 RD ISSUED FOR 60%

OWNERS REVIEW

C

TM12/03/18 RD ISSUED FOR 90%

OWNERS REVIEW

D

Page 11: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

EXTERIORINTERIOR

OZONE

BUILDING

F13 DI029

OZONE GENERATOR

NO. 1

CHILLED WATER

RETURN

A

PI

500

CW

E1 DI033

CHILLERS

CHILLED WATER

RETURN

PI

212

CW

PI

222

CW

PI

232

CW

CHILLED WATER

PUMP NO. 1 *

CW-P-210

CHILLED WATER

PUMP NO. 2 *

CW-P-220

CHILLED WATER

PUMP NO. 3 *

CW-P-230

FUTURE

CONNECTION

MAKEUP WATER

FILL CONNECTION

*

8" SST

4" SST

4" SST 8" SST

FUTURE

CONNECTION

*

*

*

4" SST

G13 DI031

OZONE GENERATOR

NO. 3

CHILLED WATER

RETURN

TIT

500

CW

TE

500

CW

EXPANSION

TANK

CW-ET-500

A

*

AIR

SEPARATOR

*

*

*

* * *

* *

* *

*

*

*

FE

211

CW

*

FE

221

CW

*

FE

231

CW

M

P12-CW-MCV-211

M

P12-CW-MCV-221

M

P12-CW-MCV-231

DO

P

1

2

-

C

W

-

M

C

V

-

X

S

-

2

1

1

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

C

-

2

1

1

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

O

-

2

1

1

DO

P

1

2

-

C

W

-

M

C

V

-

X

S

-

2

3

1

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

C

-

2

3

1

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

O

-

2

3

1

DO

P

1

2

-

C

W

-

M

C

V

-

X

S

-

2

2

1

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

C

-

2

2

1

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

O

-

2

2

1

PI

211

CW

PI

221

CW

PI

231

CW

P12-OZB-MCC-001 P12-OZB-MCC-002

AI

P

1

2

-

C

W

-

T

I

T

-

T

I

-

5

0

0

DO

P

1

2

-

C

W

-

P

-

M

D

-

2

1

0

DI

P

1

2

-

C

W

-

P

-

M

N

-

2

1

0

DI

P

1

2

-

C

W

-

P

-

H

S

-

2

1

0

DI

P

1

2

-

C

W

-

P

-

Y

A

-

2

1

0

DO

P

1

2

-

C

W

-

P

-

M

D

-

2

3

0

DI

P

1

2

-

C

W

-

P

-

M

N

-

2

3

0

DI

P

1

2

-

C

W

-

P

-

H

S

-

2

3

0

DI

P

1

2

-

C

W

-

P

-

Y

A

-

2

3

0

DO

P

1

2

-

C

W

-

P

-

M

D

-

2

2

0

DI

P

1

2

-

C

W

-

P

-

M

N

-

2

2

0

DI

P

1

2

-

C

W

-

P

-

H

S

-

2

2

0

DI

P

1

2

-

C

W

-

P

-

Y

A

-

2

2

0

F13 DI030

OZONE GENERATOR

NO. 2

CHILLED WATER

RETURN

*

*

FUTURE

CONNECTION

* 185

121

4" SST

4" SST

4" SST

109

4" SST

4" SST

110111

113 114115

118

119

117

4" SST

*

*

*

112

116

120

122

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

NOVEMBER 21, 2017 C. STILL

R. DRAIN T. McGOWN

AMISS WTP IMPROVEMENTS

CHILLED WATER PUMPS

96191 E14003

DI032 C

96191_DI032.dwg

2018

PRELIMINARY - NOT

FOR CONSTRUCTION

GENERAL NOTES:

1. NOT ALL VALVES, INSTRUMENTS, PIPING, ETC. SHOWN.

REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

SUPPLIERS SHALL PROVIDE COMPLETE AND WORKING

SYSTEMS. FINAL SIZING TO BE DETERMINED BY SUPPLIER

UNLESS OTHERWISE NOTED.

2. ALL EQUIPMENT INDICATED WITH AN ASTERISK "*" SHALL BE

PROVIDED BY OZONE SYSTEM SUPPLIER (OSS).

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400

BONTONASSOCIATES

CIVIL ENGINEERING ENVIRONMENTAL PLANNING

TM01/05/18 RD ISSUED FOR 30%

OWNERS REVIEW

A

TM02/12/18 RD ISSUED FOR

PRESELECTION

B

TM05/31/18 RD ISSUED FOR 60%

OWNERS REVIEW

C

P12-OZB-MOCP-300

TM12/03/18 RD ISSUED FOR 90%

OWNERS REVIEW

D

Page 12: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

F13 DI032

CHILLED WATER PUMPS

CHILLED WATER

RETURN

PI

511

CW

TE

511

CW

TI

511

CW

PI

521

CW

TE

521

CW

PI

531

CW

TE

531

CW

TI

521

CW

TI

531

CW

MF1 DI030

OZONE GENERATOR

NO. 2

CHILLED WATER

SUPPLY

TE

512

CW

PI

512

CW

TE

522

CW

PI

522

CW

TE

532

CW

PI

532

CW

TIT

512

CW

TIT

532

CW

F1 DI029

OZONE GENERATOR

NO. 1

CHILLED WATER

SUPPLY

G1 DI031

OZONE GENERATOR

NO. 3

CHILLED WATER

SUPPLY

.

CHEMICAL

POT FEEDER

*

FUTURE

CONNECTION

FUTURE

CONNECTION

EXTERIOR INTERIOR

OZONE

BUILDING

4" SST

8" SST

8" SST

4" SST

4" SST

4" SST

4" SST

4" SST

4" SST

4" SST

4" SST

FSL

512

CW

FSL

522

CW

FSL

532

CW

*

*

*

FE

500

CW

CHILLER

P12-CW-CH-510

CHILLER

P12-CW-CH-520

CHILLER

P12-CW-CH-530

M

P12-CW-MCV-511

M

P12-CW-MCV-521

M

P12-CW-MCV-531

*

TIT

522

CW

*

*

**

**

***

**

***

**

* *

* *

FC

511

CW

*

FC

521

CW

*

FC

531

CW

*

*

*

*

DO

P

1

2

-

C

W

-

M

C

V

-

X

S

-

5

1

1

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

C

-

5

1

1

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

O

-

5

1

1

DO

P

1

2

-

C

W

-

M

C

V

-

X

S

-

5

2

1

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

C

-

5

2

1

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

O

-

5

2

1

DO

P

1

2

-

C

W

-

M

C

V

-

X

S

-

5

3

1

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

C

-

5

3

1

DI

P

1

2

-

C

W

-

M

C

V

-

Z

S

O

-

5

3

1

DI

P

1

2

-

C

W

-

F

S

L

-

F

A

L

-

5

1

2

AI

P

1

2

-

C

W

-

T

I

T

-

T

I

-

5

1

2

DI

P

1

2

-

C

W

-

F

S

L

-

F

A

L

-

5

2

2

DI

P

1

2

-

C

W

-

F

S

L

-

F

A

L

-

5

3

2

AI

P

1

2

-

C

W

-

T

I

T

-

T

I

-

5

2

2

AI

P

1

2

-

C

W

-

T

I

T

-

T

I

-

5

3

2

AI

P

1

2

-

C

W

-

F

I

T

-

F

I

-

5

0

0

FIT

500

CW

*

DO

P

1

2

-

C

W

-

C

H

-

Y

D

-

5

1

0

DI

P

1

2

-

C

W

-

C

H

-

Y

A

-

5

1

0

DO

P

1

2

-

C

W

-

C

H

-

Y

D

-

5

2

0

DI

P

1

2

-

C

W

-

C

H

-

Y

A

-

5

2

0

DO

P

1

2

-

C

W

-

C

H

-

Y

D

-

5

3

0

DI

P

1

2

-

C

W

-

C

H

-

Y

A

-

5

3

0

GENERAL NOTES:

1. NOT ALL VALVES, INSTRUMENTS, PIPING, ETC. SHOWN.

REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

SUPPLIERS SHALL PROVIDE COMPLETE AND WORKING

SYSTEMS. FINAL SIZING TO BE DETERMINED BY SUPPLIER

UNLESS OTHERWISE NOTED.

2. ALL EQUIPMENT INDICATED WITH AN ASTERISK "*" SHALL BE

PROVIDED BY OZONE SYSTEM SUPPLIER (OSS).

3. PROVIDE METRAFLEX RUBBER EXPANSION JOINT OR

ENGINEER-APPROVED EQUAL.

FUTURE

CONNECTION

*

186

134

133

131

130

128

127

129

125124

126

NOTE 3

(TYP THIS

SHEET)

132

123

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

NOVEMBER 21, 2017 C. STILL

R. DRAIN T. McGOWN

AMISS WTP IMPROVEMENTS

CHILLERS

96191 E14003

DI033 D

96191_DI033.dwg

2018

PRELIMINARY - NOT

FOR CONSTRUCTION

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400

BONTONASSOCIATES

CIVIL ENGINEERING ENVIRONMENTAL PLANNING

TM01/05/18 RD ISSUED FOR 30%

OWNERS REVIEW

A

TM02/12/18 RD ISSUED FOR

PRESELECTION

B

TM05/31/18 RD ISSUED FOR 60%

OWNERS REVIEW

C

P12-OZB-MOCP-300

TM12/03/18 RD ISSUED FOR 90%

OWNERS REVIEW

D

Page 13: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

TO PRE-OZONE

CONTACT

BASIN NO. 2

T

PI

322

POCB

TE

300

POCB

TIT

300

POCB

PIT

300

POCB

TO PRE-OZONE

CONTACT

BASIN NO. 1

E1 DI037

OZONE GAS

CELL 1A

F1 DI038

OZONE GAS

CELL 2B

*

3" SST 3" SST 3" SST 3" SST

6" SST

*

*

D1 DI031

OZONE GAS

OZONE GENERATORS

E1 DI037

OZONE GAS

CELL 1B

F1 DI038

OZONE GAS

CELL 2A

*

M

M

P12-POCB-MCV-322

FE

322

POCB

FIT

300

POCB

P12-POCB-MCV-300

FIT

322

POCB

M

P12-POCB-MCV-321

T

PI

321

POCB

FE

321

POCB

FIT

321

POCB

M

P12-POCB-MCV-312

T

PI

312

POCB

FE

312

POCB

FIT

312

POCB

M

P12-POCB-MCV-311

T

PI

311

POCB

FE

311

POCB

FIT

311

POCB

*

* *

* * *

FC

300

POCB

*

FC

322

POCB

*

FC

312

POCB

*

FC

312

POCB

*

FC

311

POCB

*

*

*

*

*

*

*

*

DO

P

1

2

-

P

O

C

B

-

M

C

V

-

X

S

-

3

0

0

DI

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

S

C

-

3

0

0

DI

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

S

O

-

3

0

0

AI

P

1

2

-

P

O

C

B

-

P

I

T

-

P

I

-

3

0

0

AI

P

1

2

-

P

O

C

B

-

T

I

T

-

T

I

-

3

0

0

AI

P

1

2

-

P

O

C

B

-

F

I

T

-

F

I

-

3

0

0

AI

P

1

2

-

P

O

C

B

-

F

I

T

-

F

I

-

3

2

2

AI

P

1

2

-

P

O

C

B

-

F

I

T

-

F

I

-

3

2

1

AI

P

1

2

-

P

O

C

B

-

F

I

T

-

F

I

-

3

1

2

AI

P

1

2

-

P

O

C

B

-

F

I

T

-

F

I

-

3

1

1

AO

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

C

-

3

2

2

AI

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

I

-

3

2

2

DI

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

S

C

-

3

2

2

AO

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

C

-

3

2

1

AI

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

I

-

3

2

1

DI

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

S

C

-

3

2

1

AO

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

C

-

3

1

2

AI

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

I

-

3

1

2

DI

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

S

C

-

3

1

2

AO

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

C

-

3

1

1

AI

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

I

-

3

1

1

DI

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

S

C

-

3

1

1

138

137

141

140143146

144

147

136135

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

NOVEMBER 21, 2017 C. STILL

R. DRAIN T. McGOWN

AMISS WTP IMPROVEMENTS

PRE-OZONE CONTACT BASIN

GAS CONTROL

96191 E14003

DI034 D

96191_DI034.dwg

2018

PRELIMINARY - NOT

FOR CONSTRUCTION

GENERAL NOTES:

1. NOT ALL VALVES, INSTRUMENTS, PIPING, ETC. SHOWN.

REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

SUPPLIERS SHALL PROVIDE COMPLETE AND WORKING

SYSTEMS. FINAL SIZING TO BE DETERMINED BY SUPPLIER

UNLESS OTHERWISE NOTED.

2. ALL EQUIPMENT INDICATED WITH AN ASTERISK "*" SHALL BE

PROVIDED BY OZONE SYSTEM SUPPLIER (OSS).

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400

BONTONASSOCIATES

CIVIL ENGINEERING ENVIRONMENTAL PLANNING

TM01/05/18 RD ISSUED FOR 30%

OWNERS REVIEW

A

TM02/12/18 RD ISSUED FOR

PRESELECTION

B

TM05/31/18 RD ISSUED FOR 60%

OWNERS REVIEW

C

P12-POCB-RIO-300

TM12/03/18 RD ISSUED FOR 90%

OWNERS REVIEW

D

Page 14: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

TO WTP NO. 1

CONTACT

BASIN NO. 2

TE

300

OCB

TIT

300

OCB

PIT

300

OCB

TO WTP NO. 1

CONTACT

BASIN NO. 1

D13 DI031

OZONE GENERATORS

OZONE GAS

F1 DI039

CELL 1A

OZONE GAS

F1 DI039

CELL 1B

OZONE GAS

F1 DI040

CELL 2A

OZONE GAS

*

*

3" SST

2" SST 2" SST 2" SST 2" SST

*

*

F1 DI040

CELL 2B

OZONE GAS

FIT

300

OCB

M

P1-OCB-MCV-300

M

P1-OCB-MCV-322

T

PI

322

OCB

FE

322

OCB

FIT

322

OCB

M

P1-OCB-MCV-321

T

PI

321

OCB

FE

321

OCB

FIT

321

OCB

M

P1-OCB-MCV-312

T

FE

312

OCB

FIT

312

OCB

M

P1-OCB-MCV-311

T

PI

311

OCB

FE

311

OCB

FIT

311

OCB

PI

321

OCB

*

*

*

FC

300

OCB

FC

322

OCB

FC

321

OCB

FC

312

OCB

FC

311

OCB

* * *

*

*

*

*

*

*

*

*

*

*

*

*

DO

P

1

-

O

C

B

-

M

C

V

-

X

S

-

3

0

0

DI

P

1

-

O

C

B

-

M

C

V

-

Z

S

C

-

3

0

0

DI

P

1

-

O

C

B

-

M

C

V

-

Z

S

O

-

3

0

0

AI

P

1

-

O

C

B

-

P

I

T

-

P

I

-

3

0

0

AI

P

1

-

O

C

B

-

T

I

T

-

T

I

-

3

0

0

AI

P

1

-

O

C

B

-

F

I

T

-

F

I

-

3

0

0

AI

P

1

-

O

C

B

-

F

I

T

-

F

I

-

3

2

2

AI

P

1

-

O

C

B

-

F

I

T

-

F

I

-

3

2

1

AI

P

1

-

O

C

B

-

F

I

T

-

F

I

-

3

1

2

AI

P

1

-

O

C

B

-

F

I

T

-

F

I

-

3

1

1

AO

P

1

-

O

C

B

-

M

C

V

-

Z

C

-

3

2

2

AI

P

1

-

O

C

B

-

M

C

V

-

Z

I

-

3

2

2

DI

P

1

-

O

C

B

-

M

C

V

-

Z

S

C

-

3

2

2

AO

P

1

-

O

C

B

-

M

C

V

-

Z

C

-

3

2

1

AI

P

1

-

O

C

B

-

M

C

V

-

Z

I

-

3

2

1

DI

P

1

-

O

C

B

-

M

C

V

-

Z

S

C

-

3

2

1

AO

P

1

-

O

C

B

-

M

C

V

-

Z

C

-

3

1

2

AI

P

1

-

O

C

B

-

M

C

V

-

Z

I

-

3

1

2

DI

P

1

-

O

C

B

-

M

C

V

-

Z

S

C

-

3

1

2

AO

P

1

-

O

C

B

-

M

C

V

-

Z

C

-

3

1

1

AI

P

1

-

O

C

B

-

M

C

V

-

Z

I

-

3

1

1

DI

P

1

-

O

C

B

-

M

C

V

-

Z

S

C

-

3

1

1

154

153

157

156159162

160

163

152151

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

NOVEMBER 21, 2017 C. STILL

R. DRAIN T. McGOWN

AMISS WTP IMPROVEMENTS

WTP 1 POST-OZONE

GAS CONTROL

96191 E14003

DI035 D

96191_DI035.dwg

2018

PRELIMINARY - NOT

FOR CONSTRUCTION

GENERAL NOTES:

1. NOT ALL VALVES, INSTRUMENTS, PIPING, ETC. SHOWN.

REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

SUPPLIERS SHALL PROVIDE COMPLETE AND WORKING

SYSTEMS. FINAL SIZING TO BE DETERMINED BY SUPPLIER

UNLESS OTHERWISE NOTED.

2. ALL EQUIPMENT INDICATED WITH AN ASTERISK "*" SHALL BE

PROVIDED BY OZONE SYSTEM SUPPLIER (OSS).

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400

BONTONASSOCIATES

CIVIL ENGINEERING ENVIRONMENTAL PLANNING

TM01/05/18 RD ISSUED FOR 30%

OWNERS REVIEW

A

TM02/12/18 RD ISSUED FOR

PRESELECTION

B

TM05/31/18 RD ISSUED FOR 60%

OWNERS REVIEW

C

P1-OCB-RIO-300

TM12/03/18 RD ISSUED FOR 90%

OWNERS REVIEW

D

Page 15: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

TO WTP NO. 2

CONTACT

BASIN NO. 2

TE

300

OCB

TIT

300

OCB

PIT

300

OCB

TO WTP NO. 2

CONTACT

BASIN NO. 1

FUTURE

CONNECTION

F13 DI031

OZONE GENERATORS

OZONE GAS

F1 DI041

CELL 1A

OZONE GAS

F1 DI041

CELL 1B

OZONE GAS

G1 .

CELL 2A

OZONE GAS

H1 .

CELL 2B

OZONE GAS

3" SST

2" SST 2" SST 2" SST 2" SST

*

M

P2-OCB-MCV-300

FIT

300

OCB

M

P2-OCB-MCV-322

T

PI

322

OCB

FE

322

OCB

FIT

322

OCB

M

P2-OCB-MCV-321

T

PI

321

OCB

FE

321

OCB

FIT

321

OCB

M

P2-OCB-MCV-312

T

FE

312

OCB

FIT

312

OCB

M

P2-OCB-MCV-311

T

PI

311

OCB

*

*

FE

311

OCB

FIT

311

OCB

*

PI

312

OCB

*

*

*

*

*

*

*

*

*

**

*

*

*

FC

300

OCB

FC

322

OCB

FC

321

OCB

FC

312

OCB

FC

311

OCB

* * * *

DO

P

2

-

O

C

B

-

M

C

V

-

X

S

-

3

0

0

DI

P

2

-

O

C

B

-

M

C

V

-

Z

S

C

-

3

0

0

DI

P

2

-

O

C

B

-

M

C

V

-

Z

S

O

-

3

0

0

AI

P

2

-

O

C

B

-

P

I

T

-

P

I

-

3

0

0

AI

P

2

-

O

C

B

-

T

I

T

-

T

I

-

3

0

0

AI

P

2

-

O

C

B

-

F

I

T

-

F

I

-

3

0

0

AI

P

2

-

O

C

B

-

F

I

T

-

F

I

-

3

2

2

AI

P

2

-

O

C

B

-

F

I

T

-

F

I

-

3

2

1

AI

P

2

-

O

C

B

-

F

I

T

-

F

I

-

3

1

2

AI

P

2

-

O

C

B

-

F

I

T

-

F

I

-

3

1

1

AO

P

2

-

O

C

B

-

M

C

V

-

Z

C

-

3

2

2

AI

P

2

-

O

C

B

-

M

C

V

-

Z

I

-

3

2

2

DI

P

2

-

O

C

B

-

M

C

V

-

Z

S

C

-

3

2

2

AO

P

2

-

O

C

B

-

M

C

V

-

Z

C

-

3

2

1

AI

P

2

-

O

C

B

-

M

C

V

-

Z

I

-

3

2

1

DI

P

2

-

O

C

B

-

M

C

V

-

Z

S

C

-

3

2

1

AO

P

2

-

O

C

B

-

M

C

V

-

Z

C

-

3

1

2

AI

P

2

-

O

C

B

-

M

C

V

-

Z

I

-

3

1

2

DI

P

2

-

O

C

B

-

M

C

V

-

Z

S

C

-

3

1

2

AO

P

2

-

O

C

B

-

M

C

V

-

Z

C

-

3

1

1

AI

P

2

-

O

C

B

-

M

C

V

-

Z

I

-

3

1

1

DI

P

2

-

O

C

B

-

M

C

V

-

Z

S

C

-

3

1

1

171

170

174

173176179

177

180

169168

*

167

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

NOVEMBER 21, 2017 C. STILL

R. DRAIN T. McGOWN

AMISS WTP IMPROVEMENTS

WTP 2 POST-OZONE

GAS CONTROL

96191 E14003

DI036 D

96191_DI036.dwg

2018

PRELIMINARY - NOT

FOR CONSTRUCTION

GENERAL NOTES:

1. NOT ALL VALVES, INSTRUMENTS, PIPING, ETC. SHOWN.

REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

SUPPLIERS SHALL PROVIDE COMPLETE AND WORKING

SYSTEMS. FINAL SIZING TO BE DETERMINED BY SUPPLIER

UNLESS OTHERWISE NOTED.

2. ALL EQUIPMENT INDICATED WITH AN ASTERISK "*" SHALL BE

PROVIDED BY OZONE SYSTEM SUPPLIER (OSS).

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400

BONTONASSOCIATES

CIVIL ENGINEERING ENVIRONMENTAL PLANNING

TM01/05/18 RD ISSUED FOR 30%

OWNERS REVIEW

A

TM02/12/18 RD ISSUED FOR

PRESELECTION

B

TM05/31/18 RD ISSUED FOR 60%

OWNERS REVIEW

C

P2-OCB-RIO-300

TM12/03/18 RD ISSUED FOR 90%

OWNERS REVIEW

D

Page 16: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

GENERAL NOTES:

1. NOT ALL VALVES, INSTRUMENTS, PIPING, ETC. SHOWN.

REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

SUPPLIERS SHALL PROVIDE COMPLETE AND WORKING

SYSTEMS. FINAL SIZING TO BE DETERMINED BY SUPPLIER

UNLESS OTHERWISE NOTED.

2. ALL EQUIPMENT INDICATED WITH AN ASTERISK "*" SHALL BE

PROVIDED BY OZONE SYSTEM SUPPLIER (OSS).

3. POLYMER, ALUM AND SODA ASH TO BE REMOVED IN PHASE

2 DEMO.

F13 DI034

OZONE GENERATORS

OZONE GAS

H1 DI023

WTP 2E

OZONATED RAW

WATER

H1 DI024

WTP 1

OZONATED RAW

WATER

H1 DI022

WTP 2

OZONATED RAW

WATER

AE

310

pHPOCB

E13DI038

BASIN NO. 2

OZONE OFFGAS

SAMPLE

PUMP NO. 1

P12-POCB-P-310

PRE-OZONE CONTACTOR

BASIN NO. 1

NOTE 3

* *

AIT

310

pHPOCB

*

*

CELL 1A CELL 1B

G13 DI038

BASIN NO. 2

OZONATED RAW

WATER

SAMPLE TAP

EFFLUENT

WEIR

3" SST

3" SST

48" PCCP

60" DIP

18

"x1

2"

12

"x6

"

E13 DI038

BASIN NO. 1

OZONATED WATER

1/2" SST

6" SST

6" SST

42"

30"

42"

1/2" SST

1/2" SST

1" SST

*

F13 DI034

OZONE GENERATORS

OZONE GAS

D1 DI043

OZONE DESTRUCT

OZONE OFFGAS

*

*

AO

P

1

2

-

P

O

C

B

-

P

-

S

C

-

3

1

0

AI

P

1

2

-

P

O

C

B

-

P

-

S

I

-

3

1

0

DO

P

1

2

-

P

O

C

B

-

P

-

M

D

-

3

1

0

DI

P

1

2

-

P

O

C

B

-

P

-

M

N

-

3

1

0

AI

P

1

2

-

P

O

C

B

-

A

I

T

-

A

I

-

3

1

0

DI

P

1

2

-

P

O

C

B

-

P

-

H

S

-

3

1

0

DI

P

1

2

-

P

O

C

B

-

P

-

Y

A

-

3

1

0

ALUM

POLYMER

PAC

CHLORINE DIOXIDE

SODA ASH

RAW WATER

RAW WATER

RAW WATER

48"x42"

149

139

142

H13 DI015

CO2 SYSTEM

CO2

G13 DI016

CO2 SYSTEM

CO2 SOLUTION

G13 DI011

CAUSTIC SYSTEM

CAUSTIC

G13 DI015

CO2 SYSTEM

CO2

H13 DI016

CO2 SYSTEM

CO2

H13 DI011

CAUSTIC SYSTEM

CAUSTIC

RAW WATER

VAULT NO. 2

RAW WATER

VAULT NO. 1

2" SCH 80 PVC

2" SCH 80 PVC

4" SCH 80 PVC

4" SCH 80 PVC

NOTE 3

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

NOVEMBER 21, 2017 C. STILL

R. DRAIN T. McGOWN

AMISS WTP IMPROVEMENTS

PRE-OZONE CONTACT BASIN

SHEET 1

96191 E14003

DI037 D

96191_DI037.dwg

2018

PRELIMINARY - NOT

FOR CONSTRUCTION

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400

BONTONASSOCIATES

CIVIL ENGINEERING ENVIRONMENTAL PLANNING

TM01/05/18 RD ISSUED FOR 30%

OWNERS REVIEW

A

TM02/12/18 RD ISSUED FOR

PRESELECTION

B

TM05/31/18 RD ISSUED FOR 60%

OWNERS REVIEW

C

P12-POCB-RIO-060

TM12/03/18 RD ISSUED FOR 90%

OWNERS REVIEW

D

Page 17: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

AE

320

pHPOCB

SAMPLE

PUMP NO. 2

P12-OCB-P-320

PRE-OZONE CONTACTOR

BASIN NO. 1

* *

AIT

320

pHPOCB

*

*

G13 DI034

OZONE GENERATORS

OZONE GAS

E13 DI037

OZONE DESTRUCT

OZONE OFFGAS

H1 DI037

PRE-OZONE CONTACT

BASIN

OZONATED RAW

WATER

CELL 2A CELL 2B

SAMPLE TAP

EFFLUENT WEIR

B1 DI037

BASIN NO. 1

OZONATED WATER

12

"x6

"1

8"x1

2"

3" SST

3" SST

1/2" SST

6" SST

1/2" SST

1/2" SST

*

G13 DI034

OZONE GENERATORS

OZONE GAS

*

*

AO

P

1

2

-

P

O

C

B

-

P

-

S

C

-

3

2

0

AI

P

1

2

-

P

O

C

B

-

P

-

S

I

-

3

2

0

DO

P

1

2

-

P

O

C

B

-

P

-

M

D

-

3

2

0

DI

P

1

2

-

P

O

C

B

-

P

-

M

N

-

3

2

0

AI

P

1

2

-

P

O

C

B

-

A

I

T

-

A

I

-

3

2

0

DI

P

1

2

-

P

O

C

B

-

P

-

H

S

-

3

2

0

DI

P

1

2

-

P

O

C

B

-

P

-

Y

A

-

3

2

0

RAW WATER

RAW WATER

150

148

145

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

NOVEMBER 21, 2017 C. STILL

R. DRAIN T. McGOWN

AMISS WTP IMPROVEMENTS

PRE-OZONE CONTACT BASIN

SHEET 2

96191 E14003

DI038 D

96191_DI038.dwg

2018

PRELIMINARY - NOT

FOR CONSTRUCTION

GENERAL NOTES:

1. NOT ALL VALVES, INSTRUMENTS, PIPING, ETC. SHOWN.

REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

SUPPLIERS SHALL PROVIDE COMPLETE AND WORKING

SYSTEMS. FINAL SIZING TO BE DETERMINED BY SUPPLIER

UNLESS OTHERWISE NOTED.

2. ALL EQUIPMENT INDICATED WITH AN ASTERISK "*" SHALL BE

PROVIDED BY OZONE SYSTEM SUPPLIER (OSS).

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400

BONTONASSOCIATES

CIVIL ENGINEERING ENVIRONMENTAL PLANNING

TM01/05/18 RD ISSUED FOR 30%

OWNERS REVIEW

A

TM02/12/18 RD ISSUED FOR

PRESELECTION

B

TM05/31/18 RD ISSUED FOR 60%

OWNERS REVIEW

C

P12-POCB-RIO-060

TM12/03/18 RD ISSUED FOR 90%

OWNERS REVIEW

D

Page 18: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

GENERAL NOTES:

1. NOT ALL VALVES, INSTRUMENTS, PIPING, ETC. SHOWN.

REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

SUPPLIERS SHALL PROVIDE COMPLETE AND WORKING

SYSTEMS. FINAL SIZING TO BE DETERMINED BY SUPPLIER

UNLESS OTHERWISE NOTED.

2. ALL EQUIPMENT INDICATED WITH AN ASTERISK "*" SHALL BE

PROVIDED BY OZONE SYSTEM SUPPLIER (OSS).

3. CAUSTIC, FLUORIDE, AMMONIA AND FILTER AID TO BE

REMOVED. REFER TO SPECIFICATIONS FOR TIMING.

WTP NO.1 CONTACTOR

BASIN NO.1

42"

42"

42"

42"

30"42"

F13 DI035

OZONE GENERATORS

OZONE GAS

E13 DI018

WTP 1 SODIUM

THIOSULFATE SYSTEM

SODIUM THIOSULFATE

D1 DI044

OZONE DESTRUCT

OZONE OFFGAS

H13 DI012

WTP 1 FILTERS

OZONATED SETTLED

WATER

H13DI020

CHLORINE

WTP 1 CHLORINE

SYSTEM

F13 DI035

OZONE GENERATORS

OZONE GAS

NOTE 3

AIT

313

DO3OCB

AIT

312

DO3OCB

AIT

311

DO3OCB

CELL 1A CELL 1B* *

D1 DI012

WTP 1 FILTER

OZONATED SETTLED

WATER

F13DI040

BASIN NO. 2

OZONE OFFGAS

*

*

*

*

G13 DI040

BASIN NO. 2

OZONATED SETTLED

WATER

*

SAMPLE

PUMP NO. 1A

P1-OCB-P-311

SAMPLE

PUMP NO. 1B

P1-OCB-P-312

SAMPLE

PUMP NO. 1C

P1-OCB-P-313

EFFLUENT WEIR

4" SST

4" SST

2" PVC

2" SST

2" SST

2" SST

1/2" SCH 80 PVC

8"x4

"1

4"x8

"

1/2" SST

1/2" SST

1/2" SST2" SST

*

*

F1 DI040

BASIN NO. 2

OZONATED WATER

AE

313

DO3OCB

AE

312

DO3OCB

AE

311

DO3OCB

*

*

*

*

AO

P

1

-

O

C

B

-

P

-

S

C

-

3

1

2

AI

P

1

-

O

C

B

-

P

-

S

I

-

3

1

2

DO

P

1

-

O

C

B

-

P

-

M

D

-

3

1

2

DI

P

1

-

O

C

B

-

P

-

M

N

-

3

1

2

AI

P

1

-

O

C

B

-

A

I

T

-

A

I

-

3

1

1

DI

P

1

-

O

C

B

-

P

-

H

S

-

3

1

2

DI

P

1

-

O

C

B

-

P

-

Y

A

-

3

1

2

AI

P

1

-

O

C

B

-

A

I

T

-

A

I

-

3

1

2

AI

P

1

-

O

C

B

-

A

I

T

-

A

I

-

3

1

3

AO

P

1

-

O

C

B

-

P

-

S

C

-

3

1

3

AI

P

1

-

O

C

B

-

P

-

S

I

-

3

1

3

DO

P

1

-

O

C

B

-

P

-

M

D

-

3

1

3

DI

P

1

-

O

C

B

-

P

-

M

N

-

3

1

3

DI

P

1

-

O

C

B

-

P

-

H

S

-

3

1

3

DI

P

1

-

O

C

B

-

P

-

Y

A

-

3

1

3

AO

P

1

-

O

C

B

-

P

-

S

C

-

3

1

1

AI

P

1

-

O

C

B

-

P

-

S

I

-

3

1

1

DO

P

1

-

O

C

B

-

P

-

M

D

-

3

1

1

DI

P

1

-

O

C

B

-

P

-

M

N

-

3

1

1

DI

P

1

-

O

C

B

-

P

-

H

S

-

3

1

1

DI

P

1

-

O

C

B

-

P

-

Y

A

-

3

1

1

F13DI010

WTP 1 CAUSTIC

SYSTEM

CAUSTIC

JUNCTION CHAMBER

SETTLED WATER

CAUSTIC

FLUORIDE

AMMONIA

FILTER AID

JUNCTION CHAMBER

SETTLED WATER

NOTE 3

155

158

165

D1DI047

WTP 1 SEDIMENTATION

BYPASS

42" DIP

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

NOVEMBER 21, 2017 C. STILL

R. DRAIN T. McGOWN

AMISS WTP IMPROVEMENTS

WTP 1 POST-OZONE CONTACT BASIN

SHEET 1

96191 E14003

DI039 C

96191_DI039.dwg

2018

PRELIMINARY - NOT

FOR CONSTRUCTION

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400

BONTONASSOCIATES

CIVIL ENGINEERING ENVIRONMENTAL PLANNING

TM01/05/18 RD ISSUED FOR 30%

OWNERS REVIEW

A

TM02/12/18 RD ISSUED FOR

PRESELECTION

B

P1-OCB-RIO-300

P1-OCB-RIO-060

TM12/03/18 RD ISSUED FOR 90%

OWNERS REVIEW

C

Page 19: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

WTP NO.1 CONTACTOR

BASIN NO. 2

AE

322

DO3OCB

AIT

322

DO3OCB

AE

321

DO3OCB

AIT

321

DO3OCB

CELL 2A CELL 2B* *

*

*

*

*

SAMPLE

PUMP NO. 2A

P1-OCB-P-321

SAMPLE

PUMP NO. 2B

P1-OCB-P-322

G13 DI035

OZONE GENERATORS

OZONE GAS

F13 DI039

OZONE DESTRUCT

OZONE OFFGAS

I1 DI039

WTP 1 CONTACT BASIN

OZONATED SETTLED

WATER

EFFLUENT WEIR

2" SST

2" SST

2" SST

8"x4

"1

4"x8

"

4" SST

1/2" SST

1/2" SST

*

*H13 DI035

OZONE GENERATORS

OZONE GAS

F1DI039

BASIN NO. 1

OZONATED WATER

*

*

*

AO

P

1

-

O

C

B

-

P

-

S

C

-

3

2

1

AI

P

1

-

O

C

B

-

P

-

S

I

-

3

2

1

DO

P

1

-

O

C

B

-

P

-

M

D

-

3

2

1

DI

P

1

-

O

C

B

-

P

-

M

N

-

3

2

1

AI

P

1

-

O

C

B

-

A

I

T

-

A

I

-

3

2

1

DI

P

1

-

O

C

B

-

P

-

H

S

-

3

2

1

DI

P

1

-

O

C

B

-

P

-

Y

A

-

3

2

1

AI

P

1

-

O

C

B

-

A

I

T

-

A

I

-

3

2

2

AO

P

1

-

O

C

B

-

P

-

S

C

-

3

2

2

AI

P

1

-

O

C

B

-

P

-

S

I

-

3

2

2

DO

P

1

-

O

C

B

-

P

-

M

D

-

3

2

2

DI

P

1

-

O

C

B

-

P

-

M

N

-

3

2

2

DI

P

1

-

O

C

B

-

P

-

H

S

-

3

2

2

DI

P

1

-

O

C

B

-

P

-

Y

A

-

3

2

2

166

164

161

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

NOVEMBER 21, 2017 C. STILL

R. DRAIN T. McGOWN

AMISS WTP IMPROVEMENTS

WTP 1 POST-OZONE CONTACT BASIN

SHEET 2

96191 E14003

DI040 D

96191_DI040.dwg

2018

PRELIMINARY - NOT

FOR CONSTRUCTION

GENERAL NOTES:

1. NOT ALL VALVES, INSTRUMENTS, PIPING, ETC. SHOWN.

REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

SUPPLIERS SHALL PROVIDE COMPLETE AND WORKING

SYSTEMS. FINAL SIZING TO BE DETERMINED BY SUPPLIER

UNLESS OTHERWISE NOTED.

2. ALL EQUIPMENT INDICATED WITH AN ASTERISK "*" SHALL BE

PROVIDED BY OZONE SYSTEM SUPPLIER (OSS).

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400

BONTONASSOCIATES

CIVIL ENGINEERING ENVIRONMENTAL PLANNING

TM01/05/18 RD ISSUED FOR 30%

OWNERS REVIEW

A

TM02/12/18 RD ISSUED FOR

PRESELECTION

B

TM05/31/18 RD ISSUED FOR 60%

OWNERS REVIEW

C

P1-OCB-RIO-300

P1-OCB-RIO-060

TM12/03/18 RD ISSUED FOR 90%

OWNERS REVIEW

D

Page 20: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

WTP NO.2 CONTACTOR

BASIN NO.1

54"

60"

*

*

60"

*

G13 DI036

OZONE GENERATORS

OZONE GAS

F13 DI036

OZONE GENERATORS

OZONE GAS

E13 DI019

WTP 2 SODIUM

THIOSULFATE SYSTEM

SODIUM THIOSULFATE

F1 DI013

WTP 2 FILTERS

OZONATED SETTLED

WATER

H1 DI013

WTP 2 FILTERS

OZONATED SETTLED

WATER

G13DI011

CAUSTIC

WTP 2 CAUSTIC

SYSTEM

AE

313

DO3OCB

AIT

313

DO3OCB

AE

312

DO3OCB

AIT

312

DO3OCB

AE

311

DO3OCB

AIT

311

DO3OCB

*

*

SAMPLE

PUMP NO. 1A

P2-OCB-P-311

SAMPLE

PUMP NO. 1B

P2-OCB-P-312

SAMPLE

PUMP NO. 1C

P2-OCB-P-313

*

G13 DI042

BASIN NO. 2

OZONATED SETTLED

WATER

NOTE 3

CELL 1A CELL 1B

EFFLUENT WEIR

F1 DI042

BASIN NO. 2

OZONATED WATER

2" SST

2" SST

2" SST

1/2" SCH 80 PVC

4" SST

4" SST

2" PVC

8"x4

"1

4"x8

"

1/2" SST

1/2" SST

1/2" SST

*

*

E1 DI045

OZONE DESTRUCT

OZONE OFFGAS

F13DI042

BASIN NO. 2

OZONE OFFGAS

*

*

*

*

*

AO

P

2

-

O

C

B

-

P

-

S

C

-

3

1

2

AI

P

2

-

O

C

B

-

P

-

S

I

-

3

1

2

DO

P

2

-

O

C

B

-

P

-

M

D

-

3

1

2

DI

P

2

-

O

C

B

-

P

-

M

N

-

3

1

2

AI

P

2

-

O

C

B

-

A

I

T

-

A

I

-

3

1

1

DI

P

2

-

O

C

B

-

P

-

H

S

-

3

1

2

DI

P

2

-

O

C

B

-

P

-

Y

A

-

3

1

2

AI

P

2

-

O

C

B

-

A

I

T

-

A

I

-

3

1

2

AI

P

2

-

O

C

B

-

A

I

T

-

A

I

-

3

1

3

AO

P

2

-

O

C

B

-

P

-

S

C

-

3

1

3

AI

P

2

-

O

C

B

-

P

-

S

I

-

3

1

3

DO

P

2

-

O

C

B

-

P

-

M

D

-

3

1

3

DI

P

2

-

O

C

B

-

P

-

M

N

-

3

1

3

DI

P

2

-

O

C

B

-

P

-

H

S

-

3

1

3

DI

P

2

-

O

C

B

-

P

-

Y

A

-

3

1

3

AO

P

2

-

O

C

B

-

P

-

S

C

-

3

1

1

AI

P

2

-

O

C

B

-

P

-

S

I

-

3

1

1

DO

P

2

-

O

C

B

-

P

-

M

D

-

3

1

1

DI

P

2

-

O

C

B

-

P

-

M

N

-

3

1

1

DI

P

2

-

O

C

B

-

P

-

H

S

-

3

1

1

DI

P

2

-

O

C

B

-

P

-

Y

A

-

3

1

1

AMMONIA

FILTER AID

CAUSTIC

FLUORIDE

B13DI020

CHLORINE

WTP 2 CHLORINE

SYSTEM

GENERAL NOTES:

1. NOT ALL VALVES, INSTRUMENTS, PIPING, ETC. SHOWN.

REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

SUPPLIERS SHALL PROVIDE COMPLETE AND WORKING

SYSTEMS. FINAL SIZING TO BE DETERMINED BY SUPPLIER

UNLESS OTHERWISE NOTED.

2. ALL EQUIPMENT INDICATED WITH AN ASTERISK "*" SHALL BE

PROVIDED BY OZONE SYSTEM SUPPLIER (OSS).

3. CAUSTIC, FLUORIDE, AMMONIA AND FILTER AID TO BE

REMOVED. REFER TO SPECIFICATIONS FOR TIMING.

AE

305

pHOCB

AIT

305

pHOCB

AI

P

2

-

O

C

B

-

A

I

T

-

A

I

-

3

0

5

NOTE 3

A13 DI048

JUNCTION CHAMBER

SETTLED WATER

C13DI048

WTP 2 SEDIMENTATION

BYPASS

60" DIP

182

175

172

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

NOVEMBER 21, 2017 C. STILL

R. DRAIN T. McGOWN

AMISS WTP IMPROVEMENTS

WTP 2 POST-OZONE CONTACT BASIN

SHEET 1

96191 E14003

DI041 D

96191_DI041.dwg

2018

PRELIMINARY - NOT

FOR CONSTRUCTION

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400

BONTONASSOCIATES

CIVIL ENGINEERING ENVIRONMENTAL PLANNING

TM01/05/18 RD ISSUED FOR 30%

OWNERS REVIEW

A

TM02/12/18 RD ISSUED FOR

PRESELECTION

B

TM05/31/18 RD ISSUED FOR 60%

OWNERS REVIEW

C

P2-OCB-RIO-300

P2-OCB-RIO-060

TM12/03/18 RD ISSUED FOR 90%

OWNERS REVIEW

D

Page 21: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

WTP NO.2 CONTACTOR

BASIN NO. 2

*

*

*

AE

322

DO3OCB

AIT

322

DO3OCB

AE

321

DO3OCB

AIT

321

DO3OCB

*

*

SAMPLE

PUMP NO. 2A

P2-OCB-P-321

SAMPLE

PUMP NO. 2B

P2-OCB-P-322

*

CELL 2A CELL 2B

H13 DI036

OZONE GAS

OZONE GENERATOR

G13 DI036

OZONE GAS

OZONE GENERATORS

I1 DI041

OZONATED SETTLED

WATER

WTP 2 CONTACT BASIN

EFFLUENT WEIR

8"x4

"1

4"x8

"

F1DI041

OZONATED WATER

BASIN NO. 1

2" SST

2" SST

2" SST

4" SST

1/2" SST

1/2" SST

*

*

F13 DI041

OZONE OFFGAS

OZONE DESTRUCT

*

*

*

AO

P

1

-

O

C

B

-

P

-

S

C

-

3

2

1

AI

P

1

-

O

C

B

-

P

-

S

I

-

3

2

1

DO

P

1

-

O

C

B

-

P

-

M

D

-

3

2

1

DI

P

1

-

O

C

B

-

P

-

M

N

-

3

2

1

DI

P

1

-

O

C

B

-

P

-

H

S

-

3

2

1

DI

P

1

-

O

C

B

-

P

-

Y

A

-

3

2

1

AI

P

1

-

O

C

B

-

A

I

T

-

A

I

-

3

2

1

AI

P

2

-

O

C

B

-

A

I

T

-

A

I

-

3

2

2

AO

P

2

-

O

C

B

-

P

-

S

C

-

3

2

2

AI

P

2

-

O

C

B

-

P

-

S

I

-

3

2

2

DO

P

2

-

O

C

B

-

P

-

M

D

-

3

2

2

DI

P

2

-

O

C

B

-

P

-

M

N

-

3

2

2

DI

P

2

-

O

C

B

-

P

-

H

S

-

3

2

2

DI

P

2

-

O

C

B

-

P

-

Y

A

-

3

2

2

183

181

178

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

NOVEMBER 21, 2017 C. STILL

R. DRAIN T. McGOWN

AMISS WTP IMPROVEMENTS

WTP 2 POST-OZONE CONTACT BASIN

SHEET 2

96191 E14003

DI042 D

96191_DI042.dwg

2018

PRELIMINARY - NOT

FOR CONSTRUCTION

GENERAL NOTES:

1. NOT ALL VALVES, INSTRUMENTS, PIPING, ETC. SHOWN.

REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

SUPPLIERS SHALL PROVIDE COMPLETE AND WORKING

SYSTEMS. FINAL SIZING TO BE DETERMINED BY SUPPLIER

UNLESS OTHERWISE NOTED.

2. ALL EQUIPMENT INDICATED WITH AN ASTERISK "*" SHALL BE

PROVIDED BY OZONE SYSTEM SUPPLIER (OSS).

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400

BONTONASSOCIATES

CIVIL ENGINEERING ENVIRONMENTAL PLANNING

TM01/05/18 RD ISSUED FOR 30%

OWNERS REVIEW

A

TM02/12/18 RD ISSUED FOR

PRESELECTION

B

TM05/31/18 RD ISSUED FOR 60%

OWNERS REVIEW

C

P2-OCB-RIO-300

P2-OCB-RIO-060

TM12/03/18 RD ISSUED FOR 30%

OWNERS REVIEW

D

Page 22: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

HEATER

P12-POCB-HTR-310

BLOWER W/ SILENCER

P12-POCB-BLW-310

OZONE DESTRUCT SKID NO. 1 *

P12-POCB-ODU-310

PDIT

312

?POCB

PDIT

311

?POCB

AE

301

O3POCB

AIT

301

O3POCB

AE

315

O3POCB

AIT

315

O3POCB

PSH

310

?POCB

TSH

311

?POCB

TSH

312

?POCB

TE

311

?POCB

PIT

310

?POCB

FSL

310

?POCB

NOTE 3

HEATER

P12-POCB-HTR-320

BLOWER W/ SILENCER

P12-POCB-BLW-320

OZONE DESTRUCT SKID NO. 2 *

P12-POCB-ODU-320

TSH

322

?POCB

PDIT

322

?POCB

PDIT

321

?POCB

AIT

325

O3POCB

PSH

320

?POCB

TSH

321

?POCB

AE

325

O3POCB

TE

321

?POCB

PIT

320

?POCB

FSL

320

?POCB

NOTE 3

VENT TO

EXTERIOR

DRAIN

DRAIN

WALL-MOUNTED

MONITOR *

AMBIENT

AIR

WALL-MOUNTED

MONITOR *

AMBIENT

AIR

AIT

302

O3POCB

AIT

303

O2POCB

AE

302

O3POCB

AE

303

O2POCB

6" SST 6" SST

TE

322

?POCB

TE

312

?POCB

NOTE 4

EXTERIOR INTERIOR

6" SST

D13 DI037

OZONE OFFGAS

PRE-OZONE CONTACT

BASIN

TSH

323

?POCB

TSH

313

?POCB

M

P12-POCB-MCV-313

M

P12-POCB-MCV-314

M

P12-POCB-MCV-323

M

P12-POCB-MCV-324

FC

324

?POCB

FC

314

?POCB

FC

313

?OCB

FC

323

?POCB

DO

P

1

2

-

P

O

C

B

-

L

C

P

-

Y

D

-

3

1

0

AO

P

1

2

-

P

O

C

B

-

B

L

W

-

S

C

-

3

1

0

AI

P

1

2

-

P

O

C

B

-

A

I

T

-

A

I

-

3

0

1

OZONE DESTRUCT LOCAL CONTROL PANEL

P12-POCB-LCP-310

OZONE DESTRUCT LOCAL CONTROL PANEL

P12-POCB-LCP-320

TIT

311

?POCB

TIT

321

?POCB

VFD

NOTE 4

VFD

DI

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

S

C

-

3

1

3

DI

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

S

O

-

3

1

3

*

AI

P

1

2

-

P

O

C

B

-

P

I

T

-

P

I

-

3

1

0

AI

P

1

2

-

P

O

C

B

-

T

I

T

-

T

I

-

3

1

1

AI

P

1

2

-

P

O

C

B

-

T

D

I

T

-

T

D

I

-

3

1

0

AI

P

1

2

-

P

O

C

B

-

P

D

I

T

-

P

D

I

-

3

1

1

AI

P

1

2

-

P

O

C

B

-

P

D

I

T

-

P

D

I

-

3

1

2

AI

P

1

2

-

P

O

C

B

-

B

L

W

-

S

I

-

3

1

0

AI

P

1

2

-

P

O

C

B

-

A

I

T

-

A

I

-

3

1

5

TDIT

310

?

?

?

?

DI

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

S

C

-

3

1

4

AO

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

C

-

3

1

4

AI

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

I

-

3

1

4

DI

P

1

2

-

P

O

C

B

-

B

L

W

-

Y

A

-

3

1

0

DI

P

1

2

-

P

O

C

B

-

L

C

P

-

Y

B

-

3

1

0

DI

P

1

2

-

P

O

C

B

-

L

C

P

-

Y

A

-

3

1

0

DI

P

1

2

-

P

O

C

B

-

L

C

P

-

H

S

-

3

1

0

DI

P

1

2

-

P

O

C

B

-

L

C

P

-

Y

N

-

3

1

0

DO

P

1

2

-

P

O

C

B

-

L

C

P

-

Y

D

-

3

2

0

AO

P

1

2

-

P

O

C

B

-

B

L

W

-

S

C

-

3

2

0

DI

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

S

C

-

3

2

3

DI

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

S

O

-

3

2

3

AI

P

1

2

-

P

O

C

B

-

P

I

T

-

P

I

-

3

2

0

AI

P

1

2

-

P

O

C

B

-

T

I

T

-

T

I

-

3

2

1

AI

P

1

2

-

P

O

C

B

-

T

D

I

T

-

T

D

I

-

3

2

0

AI

P

1

2

-

P

O

C

B

-

P

D

I

T

-

P

D

I

-

3

2

1

AI

P

1

2

-

P

O

C

B

-

P

D

I

T

-

P

D

I

-

3

2

2

AI

P

1

2

-

P

O

C

B

-

B

L

W

-

S

I

-

3

2

0

AI

P

1

2

-

P

O

C

B

-

A

I

T

-

A

I

-

3

2

5

DI

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

S

C

-

3

2

4

AO

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

C

-

3

2

4

AI

P

1

2

-

P

O

C

B

-

M

C

V

-

Z

I

-

3

2

4

DI

P

1

2

-

P

O

C

B

-

B

L

W

-

Y

A

-

3

2

0

DI

P

1

2

-

P

O

C

B

-

L

C

P

-

Y

B

-

3

2

0

DI

P

1

2

-

P

O

C

B

-

L

C

P

-

Y

A

-

3

2

0

DI

P

1

2

-

P

O

C

B

-

L

C

P

-

H

S

-

3

2

0

DI

P

1

2

-

P

O

C

B

-

L

C

P

-

Y

N

-

3

2

0

AI

P

1

2

-

P

O

C

B

-

A

I

T

-

A

I

-

3

0

1

AI

P

1

2

-

P

O

C

B

-

A

I

T

-

A

I

-

3

0

1

TDIT

320

?

?

?

?

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

NOVEMBER 21, 2017 C. STILL

R. DRAIN T. McGOWN

AMISS WTP IMPROVEMENTS

PRE-OZONE CONTACT BASIN

DESTRUCT SKID

96191 E14003

DI043 C

96191_DI043.dwg

2018

PRELIMINARY - NOT

FOR CONSTRUCTION

GENERAL NOTES:

1. NOT ALL VALVES, INSTRUMENTS, PIPING, ETC. SHOWN.

REFER TO SPECIFICATIONS FOR ADDITIONAL

INFORMATION. SUPPLIERS SHALL PROVIDE COMPLETE

AND WORKING SYSTEMS. FINAL SIZING TO BE

DETERMINED BY SUPPLIER UNLESS OTHERWISE NOTED.

2. ALL EQUIPMENT INDICATED WITH AN ASTERISK "*" SHALL

BE PROVIDED BY OZONE SYSTEM SUPPLIER (OSS).

3. PROVIDE ENLARGED SECTION OF CLEAR PIPING FOR

COLLECTION AND VISUAL OBSERVANCE OF MOISTURE.

4. PROVIDE INLET FOR AMBIENT AIR TO BE ADDED AS

REQUIRED FOR PROPER OPERATION.

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400

BONTONASSOCIATES

CIVIL ENGINEERING ENVIRONMENTAL PLANNING

TM01/05/18 RD ISSUED FOR 30%

OWNERS REVIEW

A

TM02/12/18 RD ISSUED FOR

PRESELECTION

B

TM05/31/18 RD ISSUED FOR 60%

OWNERS REVIEW

C

P12-POCB-RIO-060

Page 23: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

HEATER

P1-OCB-HTR-310

BLOWER W/ SILENCER

P1-OCB-BLW-310

OZONE DESTRUCT SKID NO. 1 *

P1-OCB-SKD-310

PDIT

312

OCB

PDIT

311

OCB

AE

301

O3OCB

AIT

301

O3OCB

AE

315

O3OCB

AIT

315

O3OCB

PSH

310

OCB

TSH

311

OCB

TSH

312

OCB

TE

311

OCB

M

P1-OCB-MCV-314

PIT

310

OCB

TIT

311

OCB

FSL

310

OCB

NOTE 3

HEATER

P1-OCB-HTR-320

BLOWER W/ SILENCER

P1-OCB-BLW-320

OZONE DESTRUCT SKID NO. 2 *

P1-OCB-SKD-320

TSH

322

OCB

PDIT

322

OCB

PDIT

321

OCB

M

P1-OCB-MCV-323

AIT

325

O3OCB

PSH

320

OCB

TSH

321

OCB

AE

325

O3OCB

TE

321

OCB

M

P1-OCB-MCV-324

PIT

320

OCB

TIT

321

OCB

FSL

320

OCB

NOTE 3

VENT TO

EXTERIOR

DRAIN

DRAIN

WALL-MOUNTED

MONITOR *

AMBIENT

AIR

WALL-MOUNTED

MONITOR *

AMBIENT

AIR

AIT

302

O3OCB

AIT

303

O2OCB

AE

302

O3OCB

AE

303

O2OCB

EXTERIOR INTERIOR

TE

312

OCB

NOTE 4

TE

322

OCB

4" SST

4" SST

NOTE 4

M

P1-OCB-MCV-313

F13 DI039

WTP 1 POST-OZONE

CONTACT BASIN

OZONE OFFGAS

TSH

313

OCB

TSH

323

OCB

FC

314

OCB

FC

324

OCB

FC

313

OCB

FC

323

OCB

DO

P

1

-

O

C

B

-

L

C

P

-

Y

D

-

3

1

0

AO

P

1

-

O

C

B

-

B

L

W

-

S

C

-

3

1

0

AI

P

1

-

O

C

B

-

A

I

T

-

A

I

-

3

0

1

OZONE DESTRUCT LOCAL CONTROL PANEL

P1-OCB-LCP-310

OZONE DESTRUCT LOCAL CONTROL PANEL

P1-OCB-LCP-320

VFD

VFD

DI

P

1

-

O

C

B

-

M

C

V

-

Z

S

C

-

3

1

3

DI

P

1

-

O

C

B

-

M

C

V

-

Z

S

O

-

3

1

3

AI

P

1

-

O

C

B

-

P

I

T

-

P

I

-

3

1

0

AI

P

1

-

O

C

B

-

T

I

T

-

T

I

-

3

1

1

AI

P

1

-

O

C

B

-

T

D

I

T

-

T

D

I

-

3

1

0

AI

P

1

-

O

C

B

-

P

D

I

T

-

P

D

I

-

3

1

1

AI

P

1

-

O

C

B

-

P

D

I

T

-

P

D

I

-

3

1

2

AI

P

1

-

O

C

B

-

B

L

W

-

S

I

-

3

1

0

AI

P

1

-

O

C

B

-

A

I

T

-

A

I

-

3

1

5

TDIT

310

DI

P

1

-

O

C

B

-

M

C

V

-

Z

S

C

-

3

1

4

AO

P

1

-

O

C

B

-

M

C

V

-

Z

C

-

3

1

4

AI

P

1

-

O

C

B

-

M

C

V

-

Z

I

-

3

1

4

DI

P

1

-

O

C

B

-

B

L

W

-

Y

A

-

3

1

0

DI

P

1

-

O

C

B

-

L

C

P

-

Y

B

-

3

1

0

DI

P

1

-

O

C

B

-

L

C

P

-

Y

A

-

3

1

0

DI

P

1

-

O

C

B

-

L

C

P

-

H

S

-

3

1

0

DI

P

1

-

O

C

B

-

L

C

P

-

Y

N

-

3

1

0

DO

P

1

-

O

C

B

-

L

C

P

-

Y

D

-

3

2

0

AO

P

1

-

O

C

B

-

B

L

W

-

S

C

-

3

2

0

DI

P

1

-

O

C

B

-

M

C

V

-

Z

S

C

-

3

2

3

DI

P

1

-

O

C

B

-

M

C

V

-

Z

S

O

-

3

2

3

AI

P

1

-

O

C

B

-

P

I

T

-

P

I

-

3

2

0

AI

P

1

-

O

C

B

-

T

I

T

-

T

I

-

3

2

1

AI

P

1

-

O

C

B

-

T

D

I

T

-

T

D

I

-

3

2

0

AI

P

1

-

O

C

B

-

P

D

I

T

-

P

D

I

-

3

2

1

AI

P

1

-

O

C

B

-

P

D

I

T

-

P

D

I

-

3

2

2

AI

P

1

-

O

C

B

-

B

L

W

-

S

I

-

3

2

0

AI

P

1

-

O

C

B

-

A

I

T

-

A

I

-

3

2

5

DI

P

1

-

O

C

B

-

M

C

V

-

Z

S

C

-

3

2

4

AO

P

1

-

O

C

B

-

M

C

V

-

Z

C

-

3

2

4

AI

P

1

-

O

C

B

-

M

C

V

-

Z

I

-

3

2

4

DI

P

1

-

O

C

B

-

B

L

W

-

Y

A

-

3

2

0

DI

P

1

-

O

C

B

-

L

C

P

-

Y

B

-

3

2

0

DI

P

1

-

O

C

B

-

L

C

P

-

Y

A

-

3

2

0

DI

P

1

-

O

C

B

-

L

C

P

-

H

S

-

3

2

0

DI

P

1

-

O

C

B

-

L

C

P

-

Y

N

-

3

2

0

AI

P

1

-

O

C

B

-

A

I

T

-

A

I

-

3

0

1

AI

P

1

-

O

C

B

-

A

I

T

-

A

I

-

3

0

1

TDIT

320

*

VENT TO

EXTERIOR

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

NOVEMBER 21, 2017 C. STILL

R. DRAIN T. McGOWN

AMISS WTP IMPROVEMENTS

WTP 1 POST-OZONE

DESTRUCT SKID

96191 E14003

DI044 D

96191_DI044.dwg

2018

PRELIMINARY - NOT

FOR CONSTRUCTION

GENERAL NOTES:

1. NOT ALL VALVES, INSTRUMENTS, PIPING, ETC. SHOWN.

REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

SUPPLIERS SHALL PROVIDE COMPLETE AND WORKING

SYSTEMS. FINAL SIZING TO BE DETERMINED BY SUPPLIER

UNLESS OTHERWISE NOTED.

2. ALL EQUIPMENT INDICATED WITH AN ASTERISK "*" SHALL BE

PROVIDED BY OZONE SYSTEM SUPPLIER (OSS).

3. PROVIDE ENLARGED SECTION OF CLEAR PIPING FOR

COLLECTION AND VISUAL OBSERVANCE OF MOISTURE.

4. PROVIDE INLET FOR AMBIENT AIR TO BE ADDED AS

REQUIRED FOR PROPER OPERATION.

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400

BONTONASSOCIATES

CIVIL ENGINEERING ENVIRONMENTAL PLANNING

TM01/05/18 RD ISSUED FOR 30%

OWNERS REVIEW

A

TM02/12/18 RD ISSUED FOR

PRESELECTION

B

TM05/31/18 RD ISSUED FOR 60%

OWNERS REVIEW

C

P1-OCB-RIO-060

TM12/03/18 RD ISSUED FOR 90%

OWNERS REVIEW

D

Page 24: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

HEATER

P2-OCB-HTR-310

BLOWER W/ SILENCER

P2-OCB-BLW-310

OZONE DESTRUCT SKID NO. 1 *

P2-OCB-ODU-310

PDIT

312

OCB

PDIT

311

OCB

AE

301

O3OCB

AIT

301

O3OCB

AE

315

O3OCB

AIT

315

O3OCB

PSH

310

OCB

TSH

311

OCB

TSH

312

OCB

TE

311

OCB

PIT

310

OCB

TIT

311

OCB

FSL

310

OCB

NOTE 3

HEATER

P2-OCB-HTR-320

BLOWER W/ SILENCER

P2-OCB-BLW-320

OZONE DESTRUCT SKID NO. 2 *

P2-OCB-ODU-320

PDIT

322

OCB

TSH

322

OCB

PDIT

321

OCB

AE

325

O3OCB

AIT

325

O3OCB

PSH

320

OCB

TSH

321

OCB

TE

321

OCB

PIT

320

OCB

TIT

321

OCB

FSL

320

OCB

NOTE 3

VENT TO

EXTERIOR

DRAIN

DRAIN

WALL-MOUNTED

MONITOR *

AMBIENT

AIR

WALL-MOUNTED

MONITOR *

AMBIENT

AIR

AIT

302

O3OCB

AIT

303

O2OCB

AE

302

O3OCB

AE

303

O2OCB

EXTERIOR INTERIOR

TE

312

OCB

4" SST

4" SST

NOTE 4

TE

322

OCB

F13 DI041

OZONE OFFGAS

WTP 2 POST-OZONE

CONTATC BASIN

M

M

M

M

P2-OCB-MCV-313

P2-OCB-MCV-314

P2-OCB-MCV-323

P2-OCB-MCV-324

TSH

313

OCB

TSH

323

OCB

FC

313

OCB

FC

324

OCB

FC

323

OCB

DO

P

2

-

O

C

B

-

L

C

P

-

Y

D

-

3

1

0

AO

P

2

-

O

C

B

-

B

L

W

-

S

C

-

3

1

0

AI

P

2

-

O

C

B

-

A

I

T

-

A

I

-

3

0

1

OZONE DESTRUCT LOCAL CONTROL PANEL

P2-OCB-LCP-310

OZONE DESTRUCT LOCAL CONTROL PANEL

P2-OCB-LCP-320

VFD

VFD

DI

P

2

-

O

C

B

-

M

C

V

-

Z

S

C

-

3

1

3

DI

P

2

-

O

C

B

-

M

C

V

-

Z

S

O

-

3

1

3

AI

P

2

-

O

C

B

-

P

I

T

-

P

I

-

3

1

0

AI

P

2

-

O

C

B

-

T

I

T

-

T

I

-

3

1

1

AI

P

2

-

O

C

B

-

T

D

I

T

-

T

D

I

-

3

1

0

AI

P

2

-

O

C

B

-

P

D

I

T

-

P

D

I

-

3

1

1

AI

P

2

-

O

C

B

-

P

D

I

T

-

P

D

I

-

3

1

2

AI

P

2

-

O

C

B

-

B

L

W

-

S

I

-

3

1

0

AI

P

2

-

O

C

B

-

A

I

T

-

A

I

-

3

1

5

TDIT

310

DI

P

2

-

O

C

B

-

M

C

V

-

Z

S

C

-

3

1

4

AO

P

2

-

O

C

B

-

M

C

V

-

Z

C

-

3

1

4

AI

P

2

-

O

C

B

-

M

C

V

-

Z

I

-

3

1

4

DI

P

2

-

O

C

B

-

B

L

W

-

Y

A

-

3

1

0

DI

P

2

-

O

C

B

-

L

C

P

-

Y

B

-

3

1

0

DI

P

2

-

O

C

B

-

L

C

P

-

Y

A

-

3

1

0

DI

P

2

-

O

C

B

-

L

C

P

-

H

S

-

3

1

0

DI

P

2

-

O

C

B

-

L

C

P

-

Y

N

-

3

1

0

DO

P

2

-

O

C

B

-

L

C

P

-

Y

D

-

3

2

0

AO

P

2

-

O

C

B

-

B

L

W

-

S

C

-

3

2

0

DI

P

2

-

O

C

B

-

M

C

V

-

Z

S

C

-

3

2

3

DI

P

2

-

O

C

B

-

M

C

V

-

Z

S

O

-

3

2

3

AI

P

2

-

O

C

B

-

P

I

T

-

P

I

-

3

2

0

AI

P

2

-

O

C

B

-

T

I

T

-

T

I

-

3

2

1

AI

P

2

-

O

C

B

-

T

D

I

T

-

T

D

I

-

3

2

0

AI

P

2

-

O

C

B

-

P

D

I

T

-

P

D

I

-

3

2

1

AI

P

2

-

O

C

B

-

P

D

I

T

-

P

D

I

-

3

2

2

AI

P

2

-

O

C

B

-

B

L

W

-

S

I

-

3

2

0

AI

P

2

-

O

C

B

-

A

I

T

-

A

I

-

3

2

5

DI

P

2

-

O

C

B

-

M

C

V

-

Z

S

C

-

3

2

4

AO

P

2

-

O

C

B

-

M

C

V

-

Z

C

-

3

2

4

AI

P

2

-

O

C

B

-

M

C

V

-

Z

I

-

3

2

4

DI

P

2

-

O

C

B

-

B

L

W

-

Y

A

-

3

2

0

DI

P

2

-

O

C

B

-

L

C

P

-

Y

B

-

3

2

0

DI

P

2

-

O

C

B

-

L

C

P

-

Y

A

-

3

2

0

DI

P

2

-

O

C

B

-

L

C

P

-

H

S

-

3

2

0

DI

P

2

-

O

C

B

-

L

C

P

-

Y

N

-

3

2

0

AI

P

2

-

O

C

B

-

A

I

T

-

A

I

-

3

0

1

AI

P

2

-

O

C

B

-

A

I

T

-

A

I

-

3

0

1

TDIT

320

NOTE 4

FC

314

?OCB

*

VENT TO

EXTERIOR

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

NOVEMBER 21, 2017 C. STILL

R. DRAIN T. McGOWN

AMISS WTP IMPROVEMENTS

WTP 2 POST-OZONE

DESTRUCT SKID

96191 E14003

DI045 D

96191_DI045.dwg

2018

PRELIMINARY - NOT

FOR CONSTRUCTION

GENERAL NOTES:

1. NOT ALL VALVES, INSTRUMENTS, PIPING, ETC. SHOWN.

REFER TO SPECIFICATIONS FOR ADDITIONAL

INFORMATION. SUPPLIERS SHALL PROVIDE COMPLETE

AND WORKING SYSTEMS. FINAL SIZING TO BE

DETERMINED BY SUPPLIER UNLESS OTHERWISE NOTED.

2. ALL EQUIPMENT INDICATED WITH AN ASTERISK "*" SHALL

BE PROVIDED BY OZONE SYSTEM SUPPLIER (OSS).

3. PROVIDE ENLARGED SECTION OF CLEAR PIPING FOR

COLLECTION AND VISUAL OBSERVANCE OF MOISTURE.

4. PROVIDE INLET FOR AMBIENT AIR TO BE ADDED AS

REQUIRED FOR PROPER OPERATION.

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400

BONTONASSOCIATES

CIVIL ENGINEERING ENVIRONMENTAL PLANNING

TM01/05/18 RD ISSUED FOR 30%

OWNERS REVIEW

A

TM02/12/18 RD ISSUED FOR

PRESELECTION

B

TM05/31/18 RD ISSUED FOR 60%

OWNERS REVIEW

C

P2-OCB-RIO-060

TM12/03/18 RD ISSUED FOR 90%

OWNERS REVIEW

D

Page 25: RFP 18-814 Amiss Water Treatment Plant Ozone Equipment ...

CO

PY

RIG

HT

©

B

UR

NS

&

M

cD

ON

NE

LL E

NG

IN

EE

RIN

G C

OM

PA

NY

, IN

C.

13 NOVEMBER, 2018 C CABALLERO

R DRAIN

AMISS WTP IMPROVEMENTS

VALVE SCHEDULE

SHEET II

96191 E14003

D007 A

96191_D007.dwg

2018

Scale F

or M

icrofilm

ing

Inches

Millim

eters

no. date descriptionby

1 1312111098765432

I

H

G

F

E

D

C

B

A

date detailed

checkeddesigned

ofsheet sheets

project contract

rev.drawing

file

ckd

PRELIMINARY - NOT

FOR CONSTRUCTION

9400 WARD PARKWAY

KANSAS CITY, MO 64114

816-333-9400