ECAPENERGY CLAIM ADJUSTMENT PROTOCOL
A quantum step forward in handling complex claims.
8/10/2019 Rex Andrews ECAP Rev 3(1)
3/14
ENERGY CLAIM ADJUSTMENT PROTOCOL
Indemnity basedAssured contracts repairs
Team approach maximizes the proactive efforts of theAssured and Insurers. Transparency of the process isessential.
American Petroleum Institute (API) RecommendedPractices form the agreed standards for damage evaluation
The API Procedural format hastens damage assessmentand expedites repairs
The use of agreed standards simplifies the ultimateadjustment process.
8/10/2019 Rex Andrews ECAP Rev 3(1)
4/14
AMERICAN PETROLEUM INSTITUTE
8/10/2019 Rex Andrews ECAP Rev 3(1)
5/14
8/10/2019 Rex Andrews ECAP Rev 3(1)
6/14
API Recommended Practice (RP) 579
The assessment procedures in this recommended practice can be usedfor fitness-for-service assessments and/or re-rating of componentsdesigned and constructed to the following codes:
ASME B&PV Code, Section VIII, Division 1, Division 2(Fired and Unfired Pressure Vessels)
ASME B&PV Code, Section 1 (Power Boilers)
ASME B31.3 Piping Code (Process Piping)
ASME B31.1 Piping Code (Power Piping)
API 650 (Oil Storage Tanks)
API 620 (Low Pressure General Storage Tanks)
8/10/2019 Rex Andrews ECAP Rev 3(1)
7/14
8/10/2019 Rex Andrews ECAP Rev 3(1)
8/14
STEP 1 . ESTABLISH THE TEAM
Agree on common goals. The intent of the Policy is to placethe Assured back in the position he was in immediatelybefore the loss.
API standards provide independent guidelines for damageassessment and repairs. Insurers agree to provide technicalexpertise to implement the API procedures, in concert withthe Assured.
Transparency is critical. All parties must cooperate toachieve maximum benefit.
Production of a common cause report is an importantintermediate goal. Subrogation/recovery may be possible.
8/10/2019 Rex Andrews ECAP Rev 3(1)
9/14
STEP 2 . ASSESS THE DAMAGE
Zoning: overpressure & heat exposure
Prioritize vessel assessment schedule according toapplicable zoning criteria
Place orders immediately for critical items located inhighest intensity damage zones
Determine required repairs for vessels in lower intensitydamage zones
Sub-systems (piping, instrumentation, controls) assessedafter critical vessels
Investigate potential consequential effects to other units
8/10/2019 Rex Andrews ECAP Rev 3(1)
10/14
ZONES OF DARKNESS
8/10/2019 Rex Andrews ECAP Rev 3(1)
11/14
DAMAGE ZONE CRITERIA
8/10/2019 Rex Andrews ECAP Rev 3(1)
12/14
STEP 3 . CHART REPLACEMENTS ANDREPAIRS, PREPARE FOR CLAIM
Scope of work documentation for the selected EPCcontractor evolves directly from the API damage report.
Order shorter lead time components (instruments,controls, etc.), now that major items are in-process.
Engage accountants for BI, if applicable.
Consider potential milestones and magnitude of partialpayments.
Collaboration as issues arise. Betterment issues may be
likely, but addressable.