VICINITY MAP
7TH FLOOR PHASE 1DALLAS EXPRESS
CONSTRUCTION DOCUMENTSAshford | Remington | Premier
14185 DALLAS PARKWAYSUITE 1400
DALLAS, TEXAS
AERIAL
ARCHITECTKline ▪ Hardin
Architecture, Planning, InteriorsContact: Brent Kline, AIA
701 Canyon Drive, Suite 110Coppell, Texas 75019www.jacobsonline.com
972-331-5699972-769-9634 fax
TENANTAshford, Remington, Premier
Contact: Tanner Powell14185 Dallas Parkway, Suite 1150
Dallas, TX 75254Phone: 927-755-9294
AT
TS
XETE FO
SA
BR
ENT E. KLINE
10 9 76
RE
GIS
TERED ARCHITECT
09/03/2021
PROJECT
ADDRESS
CITY STATE
ZIP
COPART OFFICE TOWER
14185 DALLAS PKWY #1150
FARMERS BRANCH TX
75254
JOB NO. 21030DATE ISSUE FOR DRAWN BY
09.03.21 CONSTRUCTION BEK / KMD
ASHFORDREMINGTON
PREMIER
DALLAS EXPRESS7TH FLOOR
RENOVATION
COVER
A0.00
FEC
#?
###
#
#
????X?.A?.?
#
#
FIRE EXTINGUISHERCABINET
FIRE EXTINGUISHER (WALL BRACKET )
PLAN NOTE
ELEVATION HEIGHT
WALL TYPE
ROOM LABEL
DOOR LABEL
WINDOW LABEL
SECTION CUT KEY
ELEVATION KEY
CENTERLINE
REVISION NUMBER
CL
?.A?.?
FE
INTERIOR ROUTE CONSTRUCTION
1) AN ACCESSIBLE ROUTE, IN THE DIRECTION OF TRAVEL, SHALL NOT HAVE ASLOPE EXCEEDING 1:20 (5/8" PER FOOT), EXCEPT AT A RAMP.
2) AN ACCESSIBLE ROUTE CROSS SLOPE SHALL NOT EXCEED 1:50 (1/4" PER FOOT).3) ALL NEW FLOOR CONSTRUCTION AND FLOORING MATERIALS SHALL NOT HAVE
AN ABRUPT VERTICAL CHANGE IN FINISH SURFACE LEVEL GREATER THAN 1/4"WHEN ABUTTING EITHER EXISTING OR NEW SURFACES DESIGNATED FOR ANACCESSIBLE ROUTE.
4) THE EXPOSED EDGES OF ALL FLOORING MATERIALS SHALL BE SECURELYATTACHED TO THE FLOOR SURFACE, AND WHEN RAISED ABOVE THE FLOORSURFACE, SHALL HAVE A SLOPED EDGE TRIM (SLOPE NOT TO EXCEED 1:2)INSTALLED CONTINUOUSLY ALONG THE EDGE.
DOORS
1) ANY NEW THRESHOLD SHALL NOT EXCEED 2" IN HEIGHT, NOR 1:2 SLOPE.2) ALL ACCESSIBLE HARDWARE OPERABLE BY THE DISABLED, SHALL NOT EXCEED
A HEIGHT OF 4'-0" AFF, AND SHALL BE EASILY OPERATED WITH ONE HANDWITHOUT GRASPING, PINCHING OR TWISTING OF THE WRIST.
3) ALL ACCESSIBLE DOORS WITH A CLOSER SHALL HAVE THE CLOSER ADJUSTEDSO THAT THE CLOSING TIME, FROM A 70E OPEN ANGLE TO WITHIN 3" OF THEJAMB, IS NOT LESS THAN 3 SECONDS.
4) THE OPENING FORCE OF ALL ACCESSIBLE DOORS, EXCEPT FIRE DOORS ANDEXTERIOR DOORS, SHALL NOT EXCEED 5 POUNDS.
5) THE OPENING FORCE OF ALL ACCESSIBLE EXIT AND EMERGENCY FIRE EXITDOORS, SHALL NOT EXCEED 15 POUNDS IN THE DIRECTION OF TRAVEL FOREXITING.
6) THE OPERABLE HARDWARE ON A DOOR LEADING TO HAZARDOUS AREAS (E.G.BOILER ROOMS, MECHANICAL AND ELECTRICAL ROOMS, OTHER EQUIPMENTROOMS, AND LOADING DOCK), MAY HAVE A TEXTURED SURFACE ON THETOUCHABLE AREA. ROUND KNOBS AND PULLS ARE PERMITTED.
TOILET ROOMS
1) THE FLUSH CONTROL FOR ALL ACCESSIBLE TOILETS/URINALS SHALL NOTEXCEED 3'-8" AFF, AND SHALL BE ON THE WIDE (APPROACH) SIDE OF THETOILET. (INCLUDES TANK TYPE TOILETS)
2) THE OPERATING FORCE FOR ALL ACCESSIBLE TOILET ROOM CONTROLS(TOILETS, FAUCETS AND DISPENSERS) SHALL NOT EXCEED 5 POUNDS, AND THECONTROLS SHALL BE OPERABLE WITH ONE HAND WITHOUT GRASPING,PINCHING, OR TWISTING OF THE WRIST.
3) THE OPENING FORCE OF ALL ACCESSIBLE TOILET STALL DOORS SHALL NOTEXCEED 5 POUNDS. BOLT TYPE LOCKING HARDWARE SHALL BE OPERABLE WITHONE HAND WITHOUT GRASPING, PINCHING, OR TWISTING OF THE WRIST.
4) ACCESSIBLE TOILET PAPER DISPENSERS SHALL NOT RESTRICT THE PAPERFLOW.
5) THE TOP OF ALL LAVATORIES, EXCEPT UNDERHUNG, SHALL NOT EXCEED 34"AFF. THIS NOTE SHALL GOVERN WHEN THERE IS A DISCREPANCY WITH THECOUNTERTOP HEIGHT SHOWN ON THE DRAWINGS. NOTIFY ARCHITECT WHEN ADISCREPANCY OCCURS, AND PRIOR TO FABRICATION.
6) ACCESSIBLE LAVATORIES SHALL HAVE ALL EXPOSED HOT WATER PIPING ANDDRAIN PIPES EITHER INSULATED OR CONFIGURED TO PROTECT AGAINST SKINCONTACT. THE UNDERSIDE OF THE LAVATORY SHALL NOT HAVE ANY SHARP ORABRASIVE SURFACES.
7) ANY GRAB BAR INSTALLATION SHALL BE ABLE TO SUPPORT 250 POUNDSAPPLIED IN ANY DIRECTION.
SIGNAGE
1) ALL ACCESSIBLE PERMANENT ROOMS AND SPACES, EXITWAYS AND EXITSTAIRWAYS, SHALL HAVE SIGNAGE THAT MEETS ACCESSIBLE SIGNAGEREQUIREMENTS FOR LETTER SIZE, LETTER AND NUMBER TYPESTYLE, RAISEDLETTERS, GRADE 2 BRAILLE, COLOR/CONTRAST, AND LOCATION. THE SIGNAGEAT EXITS, WHICH ARE REQUIRED TO MEET THESE REQUIREMENTS, ARE AT THEDOOR LOCATIONS ONLY, AND DOES NOT INCLUDE THE LIGHTED EXIT SIGNAGE.
2) ALL ACCESSIBLE TOILET ROOMS SHALL BE DESIGNATED WITH ACCESSIBLETEXT SIGNAGE FOR A PERMANENT ROOM, AND THE TEXT BE PLACED DIRECTLYBELOW THE PICTOGRAM SYMBOL WHEN PICTOGRAMS ARE USED. THE SIGNAGESHALL MEET THE ACCESSIBLE SIGNAGE REQUIREMENTS FOR LETTER SIZE,LETTER AND NUMBER TYPESTYLE, RAISED LETTERS, GRADE 2 BRAILLE,COLOR/CONTRAST, AND LOCATION. THE BORDER SURROUNDING APICTOGRAM, 6" MINIMUM IN HEIGHT, SHOULD NOT BE RAISED, BUT MAY BERAISED AS LONG AS IT DOES NOT SURROUND THE RAISED LETTERS ANDBRAILLE. ALL ACCESSIBLE TOILET ROOMS WHEN NOT ALL ARE ACCESSIBLE,SHALL BE DESIGNATED WITH THE INTERNATIONAL SYMBOL OF ACCESSIBILITY.IT IS SUGGESTED THAT THE INTERNATIONAL SYMBOL BE A RAISED SYMBOL.
3) ALL ACCESSIBLE PARKING SPACES, AND PUBLIC ENTRANCES, SHALL BEDESIGNATED WITH THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGNAGE INADDITION TO ANY OTHER SIGNAGE REQUIRED FOR ACCESSIBILITY. THISSIGNAGE SHALL MEET ACCESSIBILITY REQUIREMENTS FOR COLOR/CONTRASTAND LOCATION.
4) ALL OTHER SIGNAGE ALONG THE ACCESSIBLE ROUTE THAT PROVIDESEMERGENCY INFORMATION, DIRECTIONS, OR INFORMATION ABOUTFUNCTIONAL SPACES, SHALL MEET ACCESSIBLE SIGNAGE REQUIREMENTS FORLETTER SIZE, LETTER AND NUMBER TYPESTYLE, COLOR/CONTRAST, ANDLOCATION; AND RAISED LETTERS AND GRADE 2 BRAILLE WHEN PROVIDED. IT ISSUGGESTED THAT SIGNAGE USED FOR THIS PURPOSE, IN INTERIOR SPACESAND WITHIN REACH, SHOULD HAVE RAISED LETTERS; AND MAY HAVE GRADE 2BRAILLE (OPTIONAL). RAISED LETTERS AND GRADE 2 BRAILLE IS NOT REQUIREDFOR EXTERIOR SIGNAGE AND INTERIOR SIGNAGE NOT WITHIN REACH.
5) PICTOGRAMS, OTHER THAN THE INTERNATIONAL SYMBOL OF ACCESSIBILITY,ARE NOT REQUIRED. HOWEVER, WHEN THEY ARE PROVIDED, TEXT OF THEEQUIVALENT VERBAL DESCRIPTION SHOULD BE PLACED DIRECTLY BELOW THEPICTOGRAM. THE TEXT SHALL MEET ACCESSIBLE SIGNAGE REQUIREMENTSFOR LETTER SIZE, LETTER AND NUMBER TYPESTYLE, COLOR/CONTRAST, ANDLOCATION. IT IS SUGGESTED THAT PICTOGRAMS, WHEN PROVIDED WITHINREACH, ALSO SHOULD MEET ACCESSIBLE SIGNAGE REQUIREMENTS FORRAISED LETTERS, RAISED SYMBOLS, GRADE 2 BRAILLE; AND ARE NOT TO HAVEANY RAISED BORDERS (IF PROVIDED) SURROUNDING THE RAISED LETTERS ANDBRAILLE. ACCESSIBILITY STANDARDS DO NOT REQUIRE PICTOGRAMS, IN ANYLOCATION, TO HAVE RAISED PICTURES, SYMBOLS, OR BORDERS; BUT DOESREQUIRE RAISED LETTERS AND GRADE 2 BRAILLE WHEN THE PICTOGRAM ISPART OF OR ACCOMPANIES ACCESSIBLE SIGNAGE FOR PERMANENT ROOMSAND SPACES.
TABLES, COUNTERS, WORK SURFACES
1) THE TOP SURFACE OF ALL ACCESSIBLE TABLES, COUNTERS AND/OR WORKSURFACE SHALL BE BETWEEN 28" AND 34" AFF, AND AT LEAST 36" IN LENGTH.THIS NOTE SHALL GOVERN WHEN THERE IS A DISCREPANCY WITH THEDIMENSIONS SHOWN IN THE DRAWINGS. NOTIFY ARCHITECT WHEN ADISCREPANCY OCCURS, AND PRIOR TO FABRICATION.
CONTROLS AND OPERATING MECHANISMS
1) ALL NEW CONTROLS AND OPERATING MECHANISMS REQUIRED TO BEACCESSIBLE, SHALL COMPLY WITH THE HEIGHT RANGE AND CLEAR FLOORAREA REQUIREMENTS OF THE ADA GUIDELINES [AND TEXAS ACCESSIBILITYSTANDARDS]. THE FOLLOWING HEIGHTS WILL TAKE PRECEDENCE OVERDIFFERING AND UNACCESSIBLE HEIGHTS SPECIFIED BY CONSULTANTS ANDDESIGN/BUILD CONTRACTORS, AND WHEN A SPECIFIC HEIGHT IS NOT NOTEDON THE DRAWINGS FOR A PARTICULAR ITEM AND LOCATION:
a) ELECTRICAL, TELEPHONE, COMPUTER, AND CATV OUTLETS: CENTERLINE AT16 1/2" AFF (LOWEST REACH) AS STANDARD, AND NOT TO EXCEED 46 1/2" AFF(HIGHEST REACH) WHEN NOTED TO BE HIGHER AT A PARTICULAR LOCATION.
b) LIGHT SWITCHES: CENTERLINE AT 47 1/2" AFF (HIGH REACH).c) THERMOSTATS: TOP OF OPERATING MECHANISM NOT TO EXCEED 48" AFF
(HIGH REACH).d) FIRE ALARM PULLS/STATIONS: TOP OF OPERATING MECHANISM NOT TO
EXCEED 48" AFF (HIGH REACH).e) FIRE EXTINGUISHER CABINETS: OPENING LEVER NOT TO EXCEED 48" AFF
(HIGH REACH).f) TOP OF FIRE EXTINGUISHER NOT TO EXCEED 60" AFF (UNIFORM FIRE CODE).g) OTHER DISPENSERS: REFER TO DRAWING ELEVATIONS AND/OR NOTES FOR
HEIGHTS.h) BADGE/CARD READERS AND TIME CLOCKS 48" AFF TO HIGHEST OPERABLE
PART.
ALARM SYSTEMS
1) NEW ALARM SYSTEMS ALARM SYSTEMS, SHALL COMPLY WITH ACCESSIBILITYGUIDELINES AND REQUIREMENTS.
BUSINESS AND MERCANTILE COUNTERS
1) THE TOP SURFACE OF ALL ACCESSIBLE BUSINESS AND/OR MERCANTILECOUNTERS (NOT INCLUDING WORK COUNTERS) SHALL NOT EXCEED THEHEIGHT(S) DIMENSIONED ON THE DRAWING DETAIL(S), AND BE AT LEAST 36" INLENGTH. THIS NOTE SHALL GOVERN WHEN THERE IS A DISCREPANCY WITH THEDIMENSIONS SHOWN IN THE DRAWINGS. NOTIFY ARCHITECT WHEN ADISCREPANCY OCCURS, AND PRIOR TO FABRICATION.
[A]
A/C AIR CONDITIONER (ING)ACT ACOUSTICAL TILEADA AMERICANS WITH
DISABILITIES ACTADD ADDITIONADJ ADJUSTABLEAFF ABOVE FINISHED FLOORAHU AIR HANDLING UNITALT ALTERNATEALUM ALUMINUMANOD ANODIZEDAPPROX APPROXIMATE (LY)ARCH ARCHITECT (URAL)AUTO AUTOMATICAUX AUXILIARY
[B]
BD BOARDBIT BITUMINOUSBLDG BUILDINGBLK BLOCKBLKG BLOCKINGBM BEAMBTU BRITISH THERMAL UNITBUR BUILT UP ROOF
[C]
CB CHALKBOARDCF CUBIC FEETCFMF COLD FORMED
METAL FRAMINGCG CORNER GUARDCJ CONTROL JOINTCL CENTERLINECLG CEILINGCLR CLEARCMU CONCRETE MASONRY UNITCOL COLUMNCONC CONCRETECONT CONTINUOUSCPT CARPET (ED)CR COLD ROLLEDCT CERAMIC TILECTR CENTERCW COLD WATERCY CUBIC YARD
[D]
DED DEDICATE (D)DEMO DEMOLISH (TION)DEPT DEPARTMENTDF DRINKING FOUNTAINDIA DIAMETERDIAG DIAGONALDIFF DIFFUSERDIM DIMENSION (ED)DIV DIVISIONDN DOWNDP DAMP PROOFINGDR DOORDS DOWNSPOUTDW DISHWASHERDWG DRAWING (S)
[E]
E EASTEA EACHEFS EXTERIOR FINISH SYSTEMEIFS EXTERIOR INSULATION
FINISH SYSTEMEJ EXPANSION JOINTEL ELEVATIONELEC ELECTRIC (AL)ELEV ELEVATORENGR ENGINEER (ING)EQ EQUALEQUIP EQUIPMENTESCL ESCALATOREXIST EXISTINGEXT EXTERIOR
[F]
FA FIRE ALARMFAP FIRE ALARM PANELFD FLOOR DRAINFE FIRE EXTINGUISHERFEC FIRE EXTINGUISHER CABINETFF FINISHED FLOORFFE FINISHED FLOOR ELEVATIONFHC FIRE HOSE CABINETFHS FIRE HOSE STATIONFIXT FIXTUREFND FOUNDATIONFN FENCEFT FOOT, FEETFUR DN FURR DOWNFURN FURNITUREFVC FIRE VALVE CABINETFVS FIRE VALVE STATION
[G]
GA GAUGEGAL GALLONGALV GALVANIZEDGC GENERAL CONTRACTORGCMU GLAZED CONCRETE
MASONRY UNITGEN GENERALGYP BD GYPSUM BOARD
[H]
H HIGHHB HOSE BIBHC ACCESSIBLE FIXTUREHCWD HOLLOW CORE WOOD DOORHM HOLLOW METALHORIZ HORIZONTALHP HORSE POWERHR HOURHT HEIGHTHVAC HEATING, VENTILATION,
AIR CONDITIONINGHW HOT WATERHWY HIGHWAY
[I]
IN INCHINCAND INCANDESCENTINT INTERIOR
[J]
JAN JANITORJT JOINT
[K]
KD KNOCK DOWN
[L]
L LONG, LENGTHLAM LAMINATE (D)LB(S) POUND (S)LF LINEAR FEETLH LEFT HANDLT LIGHTLVR LOUVERLW LIGHT WEIGHT
[M]
MAX MAXIMUMMB MARKER BOARDMECH MECHANICALMET METALMEZZ MEZZANINEMFR MANUFACTURERMH MANHOLEMISC MISCELLANEOUSMM MILLIMETER (S)MO MASONRY OPENINGMS METAL STUD
[N]
N NORTHNEC NATIONAL ELECTRIC CODENIC NOT IN CONTRACTNO NUMBERNRC NOISE REDUCTION
COEFFICIENTNTS NOT TO SCALE
[O]
OD OUTSIDE DIAMETEROH OPPOSITE HANDOPNG OPENINGORIG ORIGINALOSHA OCCUPATIONAL SAFETY
AND HEALTH ACT
[P]
PFAB PREFABRICATE (D)PKG PACKAGEPL PROPERTY LINEPLAM PLASTIC LAMINATEPLUMB PLUMBINGPLYWD PLYWOODPNL PANELPNT PAINTPNTD PAINTEDPR PAIRPROP PROPERTYPSF POUNDS PER SQUARE FOOTPSI POUNDS PER SQUARE INCH
[Q]
QT QUARRY TILEQTR QUARTER
[R]
RA RETURN AIRRB RUBBER BASERD ROOF DRAINREBAR REINFORCING STEEL BARSREF REFER TOREFR REFRIGERATORREV REVISED, REVISIONRH RIGHT HANDRO ROUGH OPENINGROW RIGHT OF WAYRTU ROOF TOP UNIT
[S]
S SOUTHSCHED SCHEDULE (D)SCWD SOLID CORE WOOD DOORSF SQUARE FOOT (FEET)SHTH SHEATHINGSI SQUARE INCHSIM SIMILARSP SPEAKERSPKLR SPRINKLERSQ SQUARESSTL STAINLESS STEELSTC SOUND TRANSMISSION
CLASSSTD STANDARDSTL STEELSTOR STORAGESYS SYSTEM
[T]
TA TOILET ACCESSORIESTB TACK BOARDTERR TERRAZZOTHRU THROUGHTOB TOP OF BEAMTOJ TOP OF JOISTTOL TOLERANCETOM TOP OF MASONRYTOS TOP OF STEELTOW TOP OF WALLTS TUBE STEELTYP TYPICAL
[U]
UFIN UNFINISHEDUH UNIT HEATERUL UNDERWRITER'S
LABORATORYUNO UNLESS NOTED OTHERWISEUPNTD UNPAINTED
[V]
V VOLTVB VINYL BASEVCT VINYL COMPOSITION TILEVENT VENTILATE (ER) (ED) (TION)VERT VERTICALVEST VESTIBULEVJ VEE JOINTVOL VOLUMEVT VINYL TILEVWC VINYL WALL COVERING
[W]
W WEST, WATT, WIDE, WIDTHWB WOOD BASEWC WATER CLOSETWD WOODWH WATER HEATERWHD WALL HYDRANTWT WEIGHTW/ WITHW/O WITHOUT
[Y]
YD YARD
1. THE WORK OF THIS CONTRACT INCLUDES THAT SHOWN ON THE PLANS.2. CONTRACTORS ARE TO VISIT THE SITE AND BECOME FAMILIAR WITH THE SCOPE OF
WORK BEFORE SUBMITTING A COST ESTIMATE. PERFORM ALL WORK IN ACCORDANCEWITH APPLICABLE LOCAL CODES AND ORDINANCES AND UNDER CONDITIONSESTABLISHED BY AMERICAN INSTITUTE OF ARCHITECTS DOCUMENT AIA A201_87,GENERAL CONDITIONS OF THE CONTRACT.
3. ANY VARIATIONS FROM INDICATED DIMENSIONS OR FIELD CONDITIONS SHALL BEBROUGHT TO THE IMMEDIATE ATTENTION OF THE PROJECT MANAGER AND ARCHITECT.CEASE WORK IN ANY PROBLEM AREA UNTIL A DETERMINATION IS MADE ON HOW TOPROCEED.
4. CONTRACTORS ARE TO CARRY INSURANCE OF THE TYPES AND LIMITS AS SPECIFIEDBY THE PROPERTY OWNER.
5. SECURE BUILDING PERMIT AND ALL OTHER PERMITS AND APPROVALS AS REQUIRED BYAUTHORITIES HAVING JURISDICTION AND UTILITY COMPANIES PRIOR TO BEGINNINGWORK.
6. PROVIDE A ONE_YEAR GUARANTEE (5 YEARS ON SEALED COMPRESSORS) ON ALLMATERIALS AND WORKMANSHIP BEGINNING AT DATE OF SUBSTANTIAL COMPLETION.
7. PERFORM THE WORK WITH QUALIFIED MECHANICS, UNDER THE DIRECTION OFEXPERIENCED SUPERVISION HAVING EXPERIENCE IN INSTALLING PRODUCTS,EQUIPMENT, AND SYSTEMS OF SIMILAR TYPE.
8. REMOVE RUBBISH FROM PREMISES AS OFTEN AS NECESSARY OR AS DIRECTED INORDER TO KEEP PREMISES CLEAN AND EXIT-WAYS CLEAR. PROVIDE COMPLETE ANDTHOROUGH CLEANING OF ENTIRE LEASE SPACE UPON COMPLETION OFCONSTRUCTION INCLUDING CARPET VACUUMING AND STAIN REMOVAL, CLEANINGHVAC DIFFUSERS AND GRILLES, WIPING DOWN ALL WALL, CEILING, BASE, DOOR ANDFRAME SURFACES, PLUMBING FIXTURE SURFACES, CLEANING GLASS, WINDOWMULLIONS AND SILLS, WINDOW TREATMENTS, AND WAXING RESILIENT FLOORING.
9. COORDINATE THE WORK TO ALLOW FOR THE PROPER INTRODUCTION OF MATERIALS,EQUIPMENT AND SYSTEMS WITHOUT INTERFERENCE FROM ADJACENT CONSTRUCTION.UTILIZE SPACE EFFICIENTLY TO MAXIMIZE ACCESSIBILITY FOR OTHER INSTALLATIONS.
10. CONTRACTOR TO COORDINATE THE WORK WITH THE PROPERTY MANAGER TO ALLOWACCESS TO ADJACENT LEASES AND PUBLIC SPACES AND TO SCHEDULE DELIVERY OFMATERIALS WITHOUT INTERFERING WITH NORMAL OPERATIONS. CONTRACTOR IS TOKEEP INTERRUPTIONS OF UTILITIES AND RESTRICTED ACCESS TO PUBLIC SPACES TOA MINIMUM.
11. INSTALL WORK READILY ACCESSIBLE FOR OPERATION, MAINTENANCE, AND REPAIRS.PROVIDE ACCESS DOORS IN WALLS AND CEILINGS AS NEEDED TO ACCESS CONCEALEDITEMS.
12. CONNECT NEW WORK TO EXISTING WORK IN A NEAT AND CODE APPROVED MANNER.13. PERFORM DEMOLITION AS REQUIRED TO PRODUCE THE INTENDED RESULTS. PATCH
EXISTING AFFECTED SURFACES TO MATCH ADJACENT FINISHES AND TEXTURES.14. DRAWINGS ARE PREPARED TO A SCALE AS MUCH AS POSSIBLE; HOWEVER, INDICATED
DIMENSIONS AND NOTED RELATIONSHIPS (I.E. "EQUAL" "ALIGN" "CENTER") WILLGOVERN.
15. PROTECT COMMON AREA FINISHES AND TAKE OTHER PRECAUTIONS AS NEEDEDDURING CONDUCT OF THE WORK. IMMEDIATELY MAKE REPAIRS TO SUCH FINISHES, TOMATCH EXISTING, IF DAMAGE DOES OCCUR.
16. WHEREVER PENETRATIONS ARE REQUIRED TO BE MADE IN ANY EXTERIOR ELEMENTAS PART OF THIS WORK, MAKE PENETRATIONS WATERTIGHT AND AIRTIGHT. WHEREPENETRATIONS ARE MADE IN FIRE RATED ELEMENTS, SEAL ALL PENETRATIONSWITH MATERIALS WHICH WILL MAINTAIN THE RATING OF THE ELEMENT BEINGPENETRATED.
17. NEW WALLS ARE TO BE CONSTRUCTED OF 5/8" TYPE "X" FIRE RATED GYPSUM BOARDON METAL OR WOOD STUDS AS INDICATED BY WALL TYPES.
18. PROVIDE ANY REQUIRED SUPPORT MATERIAL TO PROPERLY INSTALL ALL NEWMILLWORK, ACCESSORIES, HARDWARE, AND OTHER ITEMS NEEDING SOLIDATTACHMENT. UTILIZE FIRE RETARDANT TREATED LUMBER AND PLYWOOD (CLASS AFLAME SPREAD RATED) UNLESS NOTED OR SHOWN OTHERWISE.
19. VERIFY WITH OWNER / ARCHITECT THAT ALL EXTERIOR WINDOWS HAVE BLINDS ON ALLEXTERIOR WINDOWS.
NOTE: TOP OF FIRE EXTING. MUST NOT EXCEED 60" AFF (FIRE CODE)
ELEC.HAND/HAIRDRYER
FIREEXTING.CABINET
PAPERTOWELDISP.
TRASHCAN
SEATCOVERDISPENSER
SANITARYNAPKINDISPENSERINCLUDES TOTOP OF COINSLOT
COATHOOK
BROOM/MOPHOLDER
SOAPDISP
SANITARYNAPKINDISPOSAL
MIRRORSTANDALONE
MIRROR ATLAV ORCOUNTERTOP
ELEVATORBUTTON
LIGHTSWITCH
OUTLETSIGNAGE TOILETTISSUEDISPENSER
WATERCOOLER(HIGH)
WATERCOOLER(LOW)
CLEAR FLOOR SPACE 18" MIN. X 18" MIN. CENTERED ON TACTILE CHARACTERS
NOTE: TOE CLEARANCE 6" BEYOND KNEE CLEARANCE NOT COUNTED
LAVATORY URINAL REAR GRABBAR 36" MIN
SIDE GRAB BARLENGTH 42" MIN.
TOILET - FLUSHLEVER ON WIDESIDE OF TOILET
ADULT ACCESSIBLE MOUNTING HEIGHT SCHEDULE
PLUMBINGWALL
T.O. FLUSHHANDLE
24"-
27"
33"-
36"
18"-
19"
54" MIN12" MAX
33"-
36"42"
GRAB BARHEIGHT TOTOP OFGRIPPINGSURFACE
PLUMBINGWALL
GRAB BARHEIGHT TOTOP OFGRIPPINGSURFACE
6" MAX
17" ACCESSIBLE18" AMBULATORY
GRAB BARHEIGHT TOTOP OFGRIPPINGSURFACE
12" MIN 24" MIN
33"-
36"
TRANSFER SIDE
CENTERLINEOF TOILET
SIDEWALL /PARTITION
44" M
AX13 1/2" MIN
17" M
AX
T.O. FLUSHHANDLE
7"-9"
15" M
IN
PLUMBINGWALL
17"-25"
27"-
34" KNEE
FOR 8"DEEP
TOEFOR 9"HIGH
HIGHER OFRIM ORCOUNTERSURFACE
33"-
43"
36" M
AX
15" MIN5" MAX
T.O
. SPO
UT
T.O
. SPO
UT
60" M
AX
TEXT
TEXT
48" M
IN
TO BASELINEOF HIGHESTTACTILECHARACTER
TO BASELINEOF LOWESTTACTILECHARACTER
48"
48"
15"
NOTE: DIMSEXCLUDE FRAME
35" M
AX
40" M
AX
74" M
IN T
.O. M
IRR
OR
74" M
IN T
.O. M
IRR
OR
NOTE: OPEN FLIPLID TO CLEAR
BOTTOM OFGRAB BAR
27" M
AX
TOP OFHOOK
48" M
AX
CENTERLINEOF HANDLE
NOTE: HEIGHT OFHIGHEST
OPERABLE PART
100'-0"FINISHED FLOOR
AT
TS
XETE FO
SA
BR
ENT E. KLINE
109 76
RE
GIS
TERED A RCHITEC
T
09/03/2021
PROJECT
ADDRESS
CITY STATE
ZIP
COPART OFFICE TOWER
14185 DALLAS PKWY #1150
FARMERS BRANCH TX
75254
JOB NO. 21030
DATE ISSUE FOR DRAWN BY
09.03.21 CONSTRUCTION BEK / KMD
ASHFORDREMINGTON
PREMIER
DALLAS EXPRESS7TH FLOOR
RENOVATION
GENERALNOTES
A0.01
OFFICE702
OFFICE703
RECEPTION701
OFFICEOPEN
704
LOBBYRECEPTION
704
CONFERENCE705
NOT IN SCOPEOF WORK
NOT IN SCOPEOF WORK
BUILDING OVERALL DIAGONAL
DISTANCE = 212'-3"
EXIT SEPARATION = 66'-5"
LIFE SAFETYPLAN
A0.02SCALE:LIFE SAFETY PLAN1 1/8" = 1'-0"
AT
TS
XETE FO
SA
BR
ENT E. KLINE
109 76
RE
GIS
TERED ARCHITECT
09/03/2021
PROJECT
ADDRESS
CITY STATE
ZIP
COPART OFFICE TOWER
14185 DALLAS PKWY #1150
FARMERS BRANCH TX
75254
JOB NO. 21030DATE ISSUE FOR DRAWN BY
09.03.21 CONSTRUCTION BEK / KMD
ASHFORDREMINGTON
PREMIER
DALLAS EXPRESS7TH FLOOR
RENOVATION
OFFICE702
OFFICE703
RECEPTION701
NOT IN SCOPEOF WORK
2.A3
.01
28'-8 7/8"
23'-3
"
9'-11" 9'-11" 15'-3 3/4"
13'-1
"
35'-1 1/2"
5"
703 702
701
A
B
B
A
3
2
1
3
1 1 1
1 1 1
2 2 2
PT-02
NOT IN SCOPEOF WORK
D3
D2
D1
GENERAL PLAN NOTESA. CONTRACTOR IS TO FILL ANY HOLES IN THE SLAB OR
REPAIR SLAB SURFACE WHERE WALL ORINFRASTRUCTURE WAS REMOVED BEFORE INSTALLINGNEW FLOORING.
B. EXISTING PARTITIONS AND SUBSTRATES, INCLUDINGFLOORS, SHALL BE SUFFICIENTLY PREPARED TO RECEIVENEW FINISHES AS SCHEDULED.
C. ALL SURFACES TO BE PAINTED ARE TO BE PROPERLYPREPARED BEFORE PAINTING. THIS INCLUDES THEREMOVAL OF LOOSE PAINT, OILS AND OTHER DEBRIS ASREQUIRED BY PAINT MANUFACTURER TO ASSUREPROPER ADHESION AND COAT CONSISTENCY. ALLSURFACES ARE TO BE PRIMED.
D. ALL WALL MOUNTED SIGNS AND REMOVABLE ITEMS (E.G.ARTWORK, PICTURES, CLOCKS, FACEPLATES TO LIGHTSWITCHES, OUTLETS, ETC.) ON SURFACES TO BE PAINTEDARE TO BE CAREFULLY REMOVED AND SECURELYSTORED BEFORE PAINTING & THEN REINSTALLED IN THESAME LOCATION.
E. OTHER ITEMS THAT REMAIN THAT DO NOT RECEIVE PAINTARE TO BE PROPERLY PROTECTED FROM THEAPPLICATION OF NEW PAINT, INCLUDING, BUT NOTLIMITED TO: CEILING TILE & GRID, DIFFUSERS, SPRINKLERHEADS, FIRE ALARM EQUIPMENT, SECURITY DEVICES,EXIT LIGHTS, LIGHT FIXTURES, WINDOW TREATMENTS,PROJECTION SCREENS & SUPPORTS, SPEAKERS,SIGNAGE, THERMOSTATS/SENSORS, WALL BASE, MISC.EQUIPMENT, ACOUSTICAL PANELS, ETC.
F. ALL ELECTRICAL AND DATA RECEPTACLES LOCATED ONWALLS ARE TO MATCH EXISTING BUILDING STANDARDS.
G. FOR SECURITY SYSTEM INSTALLATION COORDINATE WITHSECURITY VENDOR.
H. AT ALL MILLWORK, ORIENT ELECTRICAL AND DATARECEPTACLES HORIZONTALLY.
I. THE LOCATIONS AND CONFIGURATIONS OF THE MODULARFURNITURE IS FOR REFERENCE ONLY. MODULARFURNITURE SUPPLIER TO PROVIDE COMPLETE SET OFPLANS AND CONFIGURATIONS. THEY SHALL BE THERESPONSIBLE PARTY FOR REMOVING, RELOCATING, ANDRECONFIGURING THE FURNITURE.
DEMO PLAN NOTESD1. CAREFULLY DEMO EXISTING MILLWORK AND/OR
SHELVING. STORE AND PROTECT FOR RE-INSTALLATIONOR RETURN TO OWNER.
D2. EQUIPMENT TO BE RELOCATED.
D3. MODULAR FURNITURE SUPPLIER RESPONSIBLE OFREMOVAL OF MODULAR FURNITURE MARKED FORDEMOLITION.
A. WHERE WALLS ARE DEMOED, PATCH AND REPAIR ADJACENTWALLS AS NEEDED.
B. DEMOLISH DASHED WALLS TO DECK, IF APPLICABLE. REMOVEANY ELECTRICAL TO NEAREST JUNCTION BOX BEHIND ADJACENTSURFACES AND CAP PER CODE.
C. ANY LOOSE CABLING ABOVE CEILING IS TO BE SUPPORTED FROMSTRUCTURE AND PROTECTED DURING DEMOLITION.
D. "OWNER" REFERS TO BUILDING FACILITY MANAGER ORASHFORD, REMINGTON AND PREMIER.
E. GC TO COORDINATE DEMOLITION SCOPE WITH ABATEMENTREPORT AS PROVIDED BY THE OWNER.
F. REMOVE EXISTING FLOORING WITHIN SCOPE AREA ANDPREPARE SUB-FLOOR FOR NEW.
DEMO GENERAL NOTES
SCALE:
0
1/4" = 1'-0"
2 4 8
PLAN NOTES1. NEW CARPETING THROUGHOUT SPACE.
2. VERIFY ELECTRIC OUTLET LOCATION PRIOR TOINSTALLATION.
3. MODULAR FURNITURE SUPPLIER RESPONSIBLE OFINSTALLATION OF MODULAR FURNITURE.
AT
TS
XETE FO
SA
BR
ENT E. KLINE
109 76
RE
GIS
TERED A RCHITEC
T
09/03/2021
PROJECT
ADDRESS
CITY STATE
ZIP
COPART OFFICE TOWER
14185 DALLAS PKWY #1150
FARMERS BRANCH TX
75254
JOB NO. 21030
DATE ISSUE FOR DRAWN BY
09.03.21 CONSTRUCTION BEK / KMD
ASHFORDREMINGTON
PREMIER
DALLAS EXPRESS7TH FLOOR
RENOVATION
FLOOR PLANSSHEET TITLE-2
A1.01
SCALE:RENOVATION FLOOR PLAN2 1/4" = 1'-0" SCALE:
DEMOLITION FLOOR PLAN1 1/4" = 1'-0"
NOT IN SCOPEOF WORK
2 2 2
3
1 1 1
NOT IN SCOPEOF WORK
A. ALL EXISTING CEILING MOUNTED INFRASTRUCTURE TOREMAIN AND PROTECTED FOR FUTURE INSTALLATION AND ISTO BE SUPPORTED FROM STRUCTURE DURING DEMOLITION.DO NOT DISCONNECT FROM POWER, IF APPLICABLE.
B. DO NOT REMOVE FIRE ALARM DEVICES OR DISCONNECTFROM EXISTING SYSTEM, OR SPRINKLER HEADS. EACHDEVICE IS TO BE SUPPORTED AND PROTECTED (BAGGED)THROUGHOUT DEMOLITION, AS RECOMMENDED BY THE FIREMARSHALL. THIS INCLUDES SMOKE DETECTORS ANDSECURITY DEVICES.
C. ANY LOOSE CABLING ABOVE CEILING IS TO BE SUPPORTEDFROM STRUCTURE ABOVE AND PROTECTED.
D. WHERE CEILINGS ARE BEING REMOVED, ALSO CAREFULLYREMOVE ALL EXISTING SUPPLY AND RETURN GRILLS. STOREAND PROTECT SUPPLY AND RETURN GRILLS FORRE-INSTALLATION OR RETURN TO OWNER.
E. WHERE CEILING ARE BEING REMOVED, ALSO REMOVE ANYDEVICES THAT ARE NOT FUNCTIONAL AND HAVE BEENABANDONED.
F. "OWNER" REFERS TO BUILDING FACILITY MANAGER ORASHFORD, REMINGTON AND PREMIER.
G. GC TO COORDINATE DEMOLITION SCOPE WITH ABATEMENTREPORT AS PROVIDED BY THE OWNER.
GENERAL DEMO CEILING NOTESA. ANY NEW CEILING TILE AND GRID REQUIRED SHALL MATCH
EXISTING BUILDING STANDARDS, UNLESS OTHERWISE NOTED.
B. ALIGN NEW GRID TO MATCH EXISTING GRID.
C. REINSTALL EXISTING MEP, FIRE SPRINKLERS, SECURITY.VERIFY LOCATIONS IN FIELD.
D. COORDINATE WITH ALL TRADES THAT WILL NEED ACCESS TOTHE CEILING THIS INCLUDES, BUT IS NOT LIMITED TO AUDIO /VISUAL SPECIALIST, MEP, SPECIALITY LIGHTING ANDSECURITY.
GENERAL CEILING NOTES
SCALE:
0
1/4" = 1'-0"
2 4 8
1. SUPPLY 100 CFM AT ECH NEW REGISTER AND REBALANCESYSTEM.
2. MATCH EXISTING SUPPLY AND RETURN GRILLS.
3. RELOCATE THERMOSTAT AS DETERMINED BY CLIENT.
CEILING NOTES
AT
TS
XETE FO
SA
BR
ENT E. KLINE
109 76
RE
GIS
TERED A RCHITEC
T
09/03/2021
PROJECT
ADDRESS
CITY STATE
ZIP
COPART OFFICE TOWER
14185 DALLAS PKWY #1150
FARMERS BRANCH TX
75254
JOB NO. 21030
DATE ISSUE FOR DRAWN BY
09.03.21 CONSTRUCTION BEK / KMD
ASHFORDREMINGTON
PREMIER
DALLAS EXPRESS7TH FLOOR
RENOVATION
CEILINGPLAN
A2.01
SCALE:REFLECTED CEILING PLAN2 1/4" = 1'-0" SCALE:
DEMO REFLECTED CEILING PLAN1 1/4" = 1'-0"
8'-1
0"
3'-0"
8'-1
0"
2"
2" 2"
DOOR TYPE - A
3'-0"
2'-0
"3'
-0"
7'-1
0"
2'-1
0"
9'-9"5 SPACED EQUALLY
PT-01
3.A3
.01
4.A3
.01
PL-07
HD-1200
LIGHT(BELOW)PT-01SS-700 4"BACK & SIDESPLASHHD-1200PL-07
FRAME TYPE - 1
G.C. TO FIELD VERIFYTO MATCH EXISTING FRAME
1'-4"2"
B-01
8'-1
0"
3'-0"
DOOR TYPE - B
G.C. TO FIELD VERIFYTO MATCH EXISTING DOOR
1'-8"
2'-1"
1/4"2'-0 3/4"
3"
4"1'
-11
1/8"
1/4"
1 1/
2"
2'-1
0"
5"
1'-1"
2 1/
4"2'
-9 3
/4"
3'-0
"
PROVIDE 4" BACK & SIDESPLASHES TO MATCHCOUNTERTOP
WALL LINE
ANCHORING RAIL:3/4" X 2 1/2" PLYWD. OR 1X3 W/FINISH
CONT. STRINGER:3/4" X 3 1/2" PLYWD. OR 1X4 -TYP.
2X CONT. TREATEDWOOD BLOCKING
CONT. 2X TREATED WD.FRAMING SUPPORT - TYP.FRONT & BACK
PLAM OVER 3/4" PLYWD.DRAWER PANEL
2X CONT. TREATEDWOOD BLKG.
SOLID SURFACECOUNTERTOP
1/4" PLYWD. BACK PANEL
3/4" WD. ADJ. SHELF
3/4" X 1 1/2" WD. FACE FRAME
PLAM OVER 3/4" PLYWD.DOOR PANEL
BASE AS SCHED.
WALL LINE
ANCHORING RAIL:3/4" X 2 1/2" PLYWD. OR 1X3 W/FINISH
2X CONT. TREATEDWOOD BLKG.
1/4" PLYWD. BACK PANELBLACK MELAMINE OVER
3/4" PLYWD. ADJ. SHELF - TYP.
3/4" WD. FIXED SHELF
2X CONT. TREATEDWOOD BLKG.
3/4" WD. MOUNTING SURFACELIGHT - UNILUME LEDSLIMLINE BY TECH LIGHTING
FIXED TOP
PLAM OVER 3/4" PLYWD.DOOR PANEL
3/4" X 3 3/4" WD. FACE FRAME
END PANEL BEYOND
3/4" WD. FIXED SHELF
RUNNER TRACK
SUSPENDED CEILING
RUNNER TRACK -SECURE TO CLG. GRID.
MET. CASING BEAD- TYP. EACH SIDE
BASE - TYP. - REF. SCHEDULE.
5/8" TYPE-X GYP. BD.EACH SIDE OF STUDS
F.V.
2 1/2" MET. STUDS AT 16" O.C.
WALL TYPE "B" WALL TYPE "A"
2 1/2" MET. STUDS AT 16" O.C.W/ FULL SOUND BATT INSULATION
G.C.TO FIELD VERIFY AND MATCH NEW WALL WITH THE
WIDTH OF EXISTING WALL
G.C.TO FIELD VERIFY AND MATCH NEW WALL WITH THE
WIDTH OF EXISTING WALL
DOOR ASSCHEDULED
MTL. STUDS, REF.WALL TYPES FORSIZES AND WALLFINISHES
REF
WAL
L TY
PE
1X WOODBLOCKING
REF WALL TYPE
1X WOODBLOCKING
RUNNERTRACK
MTL. STUDSREF WALL TYPESFOR SIZES ANDWALL FINISHES
DOOR ASSCHEDULED
MATCHEXISTING
MATCHEXISTING
RUNNER TRACK
SUSPENDED CEILING
RUNNER TRACK -SECURE TO CLG. GRID.
MET. CASING BEAD- TYP. EACH SIDE
BASE - TYP. - REF. SCHEDULE.
5/8" TYPE-X GYP. BD.EACH SIDE OF STUDS
F.V.
SOUND BATTINSULATION ABOVECEILING ALONG WALLEXTENDING 2'-0"BEYOND ON EACHSIDE
DETAIL GENERAL NOTESA. ALL HARDWARE IS TO BE BUILDING STANDARD AND MATCH EXISTING.
B. ALL DEMOLISHED DOORS AND DOOR HARDWARE TO BE RETURN TO OWNER
FOR REUSE OR STORAGE.
C. ENSURE ALL EXISTING HARDWARE TO REMAIN IS IN GOOD OPERABLE
CONDITION.
D. ALL DOORS TO HAVE WALL STOP, FLOOR STOP, OR OVERHEAD STOP AS
NEEDED BY FUNCTION.
E. ALL LOCKS TO BE KEYED PER BUILDING STANDARD AND TENANT NEEDS.
F. PROVIDE SILENCERS ON ALL FRAMES. ENSURE EXISTING FRAMES HAVE
SILENCERS.
G. ALL DOORS TO HAVE LEVER HANDLES UNLESS NOTED OTHERWISE.
H. ALL INTERIOR SURFACES TO BE CLAD WITH BLACK MELAMINE.
AT
TS
XETE FO
SA
BR
ENT E. KLINE
10 9 76
RE
GIS
TERED ARCHITECT
09/03/2021
PROJECT
ADDRESS
CITY STATE
ZIP
COPART OFFICE TOWER
14185 DALLAS PKWY #1150
FARMERS BRANCH TX
75254
JOB NO. 21030DATE ISSUE FOR DRAWN BY
09.03.21 CONSTRUCTION BEK / KMD
ASHFORDREMINGTON
PREMIER
DALLAS EXPRESS7TH FLOOR
RENOVATION
DETAILS &ELEVATIONS
A3.01
09.28.21 REVISION BEK / KMD
SCALE:DOOR & FRAME TYPES1 1/4" = 1'-0"SCALE:
COFFEE / PRINTER2 1/4" = 1'-0"SCALE:DETAILS3 1/2" = 1'-0"SCALE:
DETAILS4 1/2" = 1'-0"
SCALE:DOOR HEAD5 3" = 1'-0"SCALE:
DOOR JAMB6 3" = 1'-0"SCALE:WALL TYPES7 3" = 1'-0"
1
1
AT
TS
XETE FO
SA
BR
ENT E. KLINE
10 9 76
RE
GIS
TERED ARCHITECT
09/03/2021
PROJECT
ADDRESS
CITY STATE
ZIP
COPART OFFICE TOWER
14185 DALLAS PKWY #1150
FARMERS BRANCH TX
75254
JOB NO. 21030DATE ISSUE FOR DRAWN BY
09.03.21 CONSTRUCTION BEK / KMD
ASHFORDREMINGTON
PREMIER
DALLAS EXPRESS7TH FLOOR
RENOVATION
FINISHSCHEDULES
A3.02
Top Related