www.prongtech.comwww.prongtech.com
Transformerless design
Light Weight Corrosion-ProofPowder Coated Aluminum Frame
Lower cost than 13% industrialbleach at $1.42 per gal in bulk.
No water softeners needed.
Eliminates maintenance associatedwith bulk chemical dosing.
Round plate design allows for cell life of10-12 years.
Small footprint compared to bulktanks/pumps.
Superior e�ciency over competition
Tubular plate design allows for extendedcell life of 10-12 years
Automated �ow control and remotemonitoring options available
Customizable cell capacity toward yourexact needs.
Optimized cell design for improved e�ciency
Scalable from 1-16 cells
Ability to isolate single cell module fortroubleshooting while continuing torun the system.
On-Site System:
1-16+ kg/Hr
ULTRA LONG-LIFE HYPOCHLORITE GENERATORS
HYPER-SERIES OVERVIEW
www.prongtech.comwww.prongtech.com
Our patented tubular-plate monopolar, multi-pass cells outperform
flat-plate designsby requiring less electricity to achieve greater production
of hypochlorite with much longer cell life compared to the competition.
TECHNICAL DESIGN: TUBULAR PLATE
www.prongtech.comwww.prongtech.com
Modular System Available
from 1 to 8 Cell Banks
AUTOMATED FLOW CONTROL& REMOTE MONITORING OPTIONS AVAILABLE
from 1 to 8 Cell Banks
Lorem ipsumLorem ipsum
Lorem ipsum
HYPER I HYPER II HYPER III Mark IV
Rated FAC Capacity 1kg/hr 2kg/hr 2kg/hr 4kg/hr Cell 1, 1000A 2, 1000A 1, 2000A 2, 2000A
Treatment 1000 m3/h (4403 GPM) at 1.0 mg/L 2000 m3/h (8806 GPM) at 1.0 mg/L 2000 m3/h (8806 GPM) at 1.0 mg/L 4000 m3/h (17611 GPM) at 1.0 mg/L
Typical 2.28 to 5.0 m3/h (10 to 22 GPM) Typical 2.28 to 5.0 m3/h (10 to 22 GPM) Typical 2.28 to 5.0 m3/h (10 to 22 GPM) Typical 2.28 to 5.0 m3/h (10 to 22 GPM)
2.5 m3/h (11.0 GPM) @ 400mg/L 2.5 m3/h (11.0 GPM) @ 800 mg/L 2.5 m3/h (11.0 GPM) @ 800 mg/L 2.5 m3/h (11.0 GPM) @ 1600 mg/L
5.0 m3/h (22.0 GPM) @ 200mg/L 5.0 m3/h (22.0 GPM) @ 400 mg/L 5.0 m3/h (22.0 GPM) @ 400 mg/L 5.0 m3/h (22.0 GPM) @ 800 mg/L
1" ANSI Flange 1” ANSI Flange 1” ANSI Flange 1” ANSI FlangeDrain 1" NPT 1” NPT 1” NPT 1” NPT
Power Consump�on 5.4 KW DC at max capacity 10.8 KW DC at max capacity 10 KW DC at max capacity
460V ±5% 50/60 Hz | 12.5A | 3 phase (site voltage to be verified by owner)
460V ±5% 50/60 Hz | 25A | 3 phase (site voltage to be verified by owner)
460V ±5% 50/60 Hz | 25A | 3 phase (site voltage to be verified by owner)
115V ±5% 60 Hz | 15A | 1 phase (site voltage to be verified by owner)
115V ±5% 60 Hz | 15A | 1 phase (site voltage to be verified by owner)
115V ±5% 60 Hz | 15A | 1 phase (site voltage to be verified by owner)
Footprint: 1041 mm wide x 813 mm deep Footprint: 1041 mm wide x 813 mm deep Footprint: 1270 mm wide x 851 mm deep 1270 mm wide x 851 mm deep
Envelope: 1041 mm wide x 813 mm deep x 1505 mm tall
Envelope: 1041 mm wide x 813 mm deep x 1505 mm tall
Envelope: 1270mm wide x 876 mm deep x 1676 mm tall
1270mm wide x 876 mm deep x
One EC1K-W Cell: 1 kg/hr, 1000A cell Two EC1K-W Cell: 1 kg/hr, 1000A cell One EC2KL-W Cell: 2 kg/hr, 2000A cell Op�mized for efficient opera�on from 20°C to 50°C
Op�mized for efficient opera�on from 20°C to 50°C
Op�mized for efficient opera�on from 20°C to 50°C
0.5m3/hr (2.2 GPM) @ 2000 mg/L 1.0m3/hr (4.4 GPM) @ 2000 mg/L 1.0m3/hr (4.4 GPM) @ 2000 mg/L 2.0m3/hr (8.8 GPM) @ 2000 mg/L
Coa�ng
One EC1K: Cold water MMO coa�ng on the electroly�c cell Op�mized for chlorina�on conversion efficiency from 0 to 50°C
Two EC1K: Cold water MMO coa�ng on the electroly�c cell Op�mized for chlorina�on conversion efficiency from 0 to 50°C
One EC2K: Cold water MMO coa�ng on the electroly�c cell Op�mized for chlorina�on conversion efficiency from 0 to 50°C
Internally wired 480V, 3-phase to 115V 1-phase transformer
Internally wired 480V, 3-phase to 115V 1-phase transformer
Internally wired 480V, 3-phase to 115V 1-phase transformer
Removes need for separate 115V 1-phase power
Removes need for separate 115V 1-phase power
Removes need for separate 115V 1-phase power
* Output rated at salinity (3.5%) and water temperature (65°F, 18.3°C)
* Output rated at salinity (3.5%) and water temperature (65°F, 18.3°C)
* Output rated at salinity (3.5%) and water temperature (65°F, 18.3°C)
* Output rated at salinity (3.5%) and water temperature (65°F, 18.3
Cell Details
Cell Flow Rate
Power Peak Opera�on
Dimensions
Rec�fier,water cooled SMPS
18VDC / 1000A18VDC / 1000A
Customizable Options
18VDC / 2000A 18VDC / 2000A
115V Transformer
www.prongtech.com
HYPER I HYPER II HYPER III
Rated FAC Capacity 1kg/hr 2kg/hr 2kg/hrCell 1, 1000A 2, 1000A 1, 2000A
Treatment 1000 m3/h (4403 GPM) at 1.0 mg/L 2000 m3/h (8806 GPM) at 1.0 mg/L 2000 m3/h (8806 GPM) at 1.0 mg/L
Typical 2.28 to 5.0 m3/h (10 to 22 GPM) Typical 2.28 to 5.0 m3/h (10 to 22 GPM) Typical 2.28 to 5.0 m3/h (10 to 22 GPM)
2.5 m3/h (11.0 GPM) @ 400mg/L 2.5 m3/h (11.0 GPM) @ 800 mg/L 2.5 m3/h (11.0 GPM) @ 800 mg/L
5.0 m3/h (22.0 GPM) @ 200mg/L 5.0 m3/h (22.0 GPM) @ 400 mg/L 5.0 m3/h (22.0 GPM) @ 400 mg/L
1" ANSI Flange 1” ANSI Flange 1” ANSI FlangeDrain 1" NPT 1” NPT 1” NPT
Power Consump�on 5.4 KW DC at max capacity 10.8 KW DC at max capacity 10 KW DC at max capacity
460V ±5% 50/0/0 60 Hz | 12.5A | 3 phase (sitevoltage to be verified by owner)
460V ±5% 50/0/0 60 Hz | 25A | 3 phase (sitevoltage to be verified by owner)
460V ±5% 50/0/0 60 Hz | 25A | 3 phase (sitevoltage to be verified by owner)
115V ±5% 60 Hz | 15A | 1 phase (site voltageto be verified by owner)
115V ±5% 60 Hz | 15A | 1 phase (sitevoltage to be verified by owner)
115V ±5% 60 Hz | 15A | 1 phase (sitevoltage to be verified by owner)
Footprint: 1041 mm wide x 813 mm deep Footprint: 1041 mm wide x 813 mm deep Footprint: 1270 mm wide x 851 mm deep
Envelope: 1041 mm wide x 813 mm deep x1505 mm tall
Envelope: 1041 mm wide x 813 mm deep x1505 mm tall
Envelope: 1270mm wide x 876 mm deep x1676 mm tall
One EC1K-W Cell: 1 kg/hr, 1000A cell TwTwT o EC1K-W Cell: 1 kg/hr, 1000A cell One EC2KL-W Cell: 2 kg/hr, 2000A cellOp�mized for efficient opera�on from 20°Cto 50°C
Op�mized for efficient opera�on from20°C to 50°C
Op�mized for efficient opera�on from20°C to 50°C
0.5m3/hr (2.2 GPM) @ 2000 mg/L 1.0m3/hr (4.4 GPM) @ 2000 mg/L 1.0m3/hr (4.4 GPM) @ 2000 mg/L
Coa�ng
One EC1K: Cold water MMO coa�ng on theelectroly�c cell Op�mized for chlorina�onconversion efficiency from 0 to 50°C
TwTwT o EC1K: Cold water MMO coa�ng on theelectroly�c cell Op�mized for chlorina�onconversion efficiency from 0 to 50°C
One EC2K: Cold water MMO coa�ng on theelectroly�c cell Op�mized for chlorina�onconversion efficiency from 0 to 50°C
Internally wired 480V, 3-phase to 115V 1-phase transformer
Internally wired 480V, 3-phase to 115V 1-phase transformer
Internally wired 480V, 3-phase to 115V 1-phase transformer
Removes need for separate 115V 1-phasepower
Removes need for separate 115V 1-phasepower
Removes need for separate 115V 1-phasepower
* Outptpt ut rated at salinitytyt (3.5%) and watertemperature (65°F,F,F 18.3°C)C)C
* Outptpt ut rated at salinitytyt (3.5%) and watertemperature (65°F,F,F 18.3°C)C)C
* Outptpt ut rated at salinitytyt (3.5%) and watertemperature (65°F,F,F 18.3°C)C)C
Cell Details
Cell Flow Rate
Power Peak Opera�on
Dimensions
Rec�fier,water cooled SMPS
18VDC / 1000A18VDC / 1000A 18VDC / 2000A
115V Transformer
www.prongtech.com
SYSTEM SPECIFICATIONS
www.prongtech.comwww.prongtech.com
Pronghorn Technologies, LLC1379 N. Cedar Street Suite #104 Laramie, Wyoming 82072 USA
https://prongtech.com/[email protected] /307-206-2330 /
* Output rated at salinity (3.5%) and water temperature (65°F, 18.3
Mark III HYPER IV HYPER V HYPER VI HYPER VI+ Custom
Systems4kg/hr 8kg/hr 16kg/hr 16kg/hr - 128kg/hr2, 2000A 2, 4000A 4, 4000A
3/h (8806 GPM) at 1.0 mg/L 4000 m3/h (17611 GPM) at 1.0 mg/L8,000 m3/h (35,224 GPM) at 1.0 mg/L
16,000 m3/h (70446 GPM) at 1.0 mg/L
Typical 2.28 to 5.0 m3/h (10 to 22 GPM) Typical 2.28 to 5.0 m3/h (10 to 22 GPM)Typical 4.0 to 10.0 m3/h (18 to 44 GPM)
Typical 8.0 to 10.0 m3/h (35 to 44 GPM)
3/h (11.0 GPM) @ 800 mg/L 2.5 m3/h (11.0 GPM) @ 1600 mg/L4 m3/h (18 GPM) @ 2000 mg/L
8 m3/h (35 GPM) @ 2000 mg/L
3/h (22.0 GPM) @ 400 mg/L 5.0 m3/h (22.0 GPM) @ 800 mg/L10 m3/h (44 GPM) @ 800 mg/L
10 m3/h (88 GPM) @ 1600 mg/L
1” ANSI Flange 1-1/2" ANSI Flange 1-1/2” ANSI Flange1” NPT 1" NPT 1” NPT
10 KW DC at max capacity 20 KW DC at max capacity 43.2 KW DC at max capacity 18 KW DC at max capacity
460V ±5% 50/60 Hz | 25A | 3 phase (site voltage to be verified by owner)
460V ±5% 50/60 Hz | 55A | 3 phase (site voltage to be verified by owner)
460V ±5% 50/60 Hz | 110A | 3 phase (site voltage to be verified by owner)
460V ±5% 50/60 Hz | 225A | 3 phase (site voltage to be verified by owner)
115V ±5% 60 Hz | 15A | 1 phase (site voltage to be verified by owner)
115V ±5% 60 Hz | 15A | 1 phase (site voltage to be verified by owner)
115V ±5% 60 Hz | 20A | 1 phase (site voltage to be verified by owner)
115V ±5% 60 Hz | 20A | 1 phase (site voltage to be verified by owner)
1270 mm wide x 851 mm deep Footprint: 1270 mm wide x 851 mm deep TBD TBD
1270mm wide x 876 mm deep x Envelope: 1270mm wide x 876 mm deep x 1676 mm tall
TBD TBD
One EC2KL-W Cell: 2 kg/hr, 2000A cell Two EC2KL-W Cell: 2 kg/hr, 2000A cell Op�mized for efficient opera�on from Op�mized for efficient opera�on from
20°C to 50°C1.0m3/hr (4.4 GPM) @ 2000 mg/L 2.0m3/hr (8.8 GPM) @ 2000 mg/L
Cold water MMO coa�ng on the electroly�c cell Op�mized for chlorina�on conversion efficiency from 0 to 50°C
Two EC2K: Cold water MMO coa�ng on the electroly�c cell Op�mized for chlorina�on conversion efficiency from 0 to 50°C
$5,000Internally wired 480V, 3-phase to 115V 1-
phase transformerInternally wired 480V, 3-phase to 115V 1-
phase transformer Removes need for separate 115V 1-phase
powerRemoves need for separate 115V 1-phase
power$1,000
* Output rated at salinity (3.5%) and water temperature (65°F, 18.3°C) ° C)
18VDC / 4000A 36VDC / 4000A18VDC / 2000A 18VDC / 2000A
SYSTEM SPECIFICATIONS
Top Related