Skanska Shimmick Herzog
Phone: 951.368.6402Milpitas, CA 95035
1436 California Circle
PROJECT:
JOB NO:CONTRACT NO:
98005
VTA Berryessa Extension ProjectC700
TRANSMITTALNo. 02466
TO: Mark T. Massman, PEValley Transportation Authority1436 California Circle
4/16/2014DATE:REF:
Milpitas, CA 95035
SENT VIA:
Shop Drawings Approval Approved as SubmittedWE ARE SENDING:
Letter Your Use Approved as NotedPrints As Requested Returned After LoanChange Order Review and Comment ResubmitPlans SubmitSamples ReturnedSpecifications Returned for Corrections
Other: Copy of Submittal
Attached
Separate Cover Via: Due Date:
ACTION TAKEN:SUBMITTED FOR:
ITEM NO. COPIES DATE ITEM NUMBER REV. NO. DESCRIPTION STATUS
101 FIO4/16/2014 Copy of Submittal 22 14 01 1.05C.003Plumbing Materials Product Data
Remarks: **NOTE** For Information Only
CC: Sent: Thomas W. Sutton
f_tr_01_usac_01_ws_098005
SVBX - Berryessa Extension
SUBMITTAL REVIEW
Submittal Title: Document Control
Spec Section & P a r a g r a p h # (i.e, 01 31 01-1.04B): Sub No.:
Discipline: Rev No.:
□ For EOR Approval □ For VTA Approval □ For VTA Information Only □ For Third Party
Description of Item Submitted
(Type size, model #, etc)
Type of Submittal( Shop
dwg, samples, matls)
Spec Parameter & Section #
(General Req, Contract, Performance Spec, Tech Spec)
Drawing Sheet #
Submittal Prepared By: Date Submitted: Requested Response Date:
Subcontractor/Supplier, If Applicable:
Deviation: No( ) Yes( ) See Notes Substitution: No( ) Yes( ) See Attached Information
Deviation/Substitution Notes (attach additional pages if necessary):
YES NO N/A
Submittal Reviewer's Checklist
1. Are specification and contract drawing references correct and included? (If not change or add them) □ □ □
2. Are the submittal date & requested return date included? (ASAP is not acceptable) □ □ □
3. Have you reviewed the specification section which requires this submittal? □ □ □
4. Do all materials submitted meet the applicable specification(s)? □ □ □
5. Are any deviations or substitutions clearly defined in the submittal notes above? □ □ □
6. Have all resubmittal comments been addressed? □ □ □
7. If required, does the submittal have a PE stamp from a Professional Engineer? □ □ □
8. Has the subcontractor/supplier signed and dated the submittal? □ □ □
9. Have you spot checked dimensions, unit weights, quantities, size, etcB with Plans? □ □ □
10. If required, are samples the correct quantity, size, type, and are labeled correctly? □ □ □
11. Is the presentation satisfactory (pages numbered, bound, tabs, spelling/grammar, etc.)? □ □ □
12. Is the correct number of legible copies being submitted? □ □ □
SSH Coordina
(PRINT NAME)
Signature:
Expected Rev
tor:
Date:
iew Hours:
Issue Cost Code:______________________________________
□ Civil □ Structures □ Utililities □ Stations □ Landscape □ Geotech □ Traffic □ Guideway □ Track□ Systems □ Electrical
22 14 01 Storm Drainage - Plumbing
22 14 01 - 1.05C 22 14 01-006
00
No Hub Class B Storm Drainage Product DataDrainage Pipe and Fittings - Below GradeDrains RD-1Drains OFD-1Drains OFD-1, DSN-1Drains PD-1
Product DataProduct DataProduct DataProduct Data
Product Data22 14 01 - 2.02A22 14 01 - 2.02A
22 14 01 - 2.03E22 14 01 - 2.03B
22 14 01 - 2.03G22 14 01 - 2.03F
Grace Li 4/11/14 4/18/14
Blocka
Substitution: Drainage Pipe and Fittings - Below Grade
✔
✔ ✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
Michael Sckreckengost
1
4/11/14
Approval
✔
APPROVAL ACTION (This Section to be completed by EOR)
Discipline Reviewed:
Initial Reviewer & Date: Hours Used Reviewing:
Final Reviewer & Title: Date: Review Code:
Engineer Review Code: ( ANN-Exceptions Noted, No Re-submittal Required), (ANR-Exceptions Noted, Re-submittal Required),
(FRO-For Record Only), (NET-No Exceptions Taken), (RRR-Rejected, Revised & Resubmit)
EOR Comments:
APPROVAL ACTION (This Section to be completed by EOR)
Discipline Reviewed:
Initial Reviewer & Title: Date: Hours Used Reviewing:
Final Reviewer & Title: Date: Review Code:
Engineer Review Code: ( ANN-Exceptions Noted, No Re-submittal Required), (ANR-Exceptions Noted, Re-submittal Required),
(FRO-For Record Only), (NET-No Exceptions Taken), (RRR-Rejected, Revised & Resubmit)
EOR Comments:
APPROVAL ACTION (This Section to be completed by EOR)
Discipline Reviewed:
Initial Reviewer & Title: Date: Hours Used Reviewing:
Final Reviewer & Title: Date: Review Code:
Engineer Review Code: ( ANN-Exceptions Noted, No Re-submittal Required), (ANR-Exceptions Noted, Re-submittal Required),
(FRO-For Record Only), (NET-No Exceptions Taken), (RRR-Rejected, Revised & Resubmit)
EOR Comments:
Reviewer & Title:
Design Coordinator :
Initial Reviewer &
Final Reviewer & Title:
Reviewer & Title:
Design Coordinator :
Initial Reviewer &
Final Reviewer & Title:
Reviewer & Title:
Design Coordinator :
Blocka Construction Inc.4455 Enterprise StreetFremont CA 94538510-657-3686
Submittal Cover Sheet
04/06/2014
To: Skanska-Shimmick-Herzog
License:
Submittal Description:
679326 Submittal Date:
Storm Drainage - Plumbing
Project:BART Berryessa ExtensionMilpitas & Berryessa StationsSanta Clara County
4182
22 14 01
1436 California CircleMilpitas CA 95035
BCI Record No: 3763
Item Status Notes
For Approval 22 14 01 - Storm Drainage - PlumbingNotes/Clarifications:
Spec Section/Submittal No.:
Grace Li
SSuubbmmiittttaallBBAARRTT -- BBeerrrryyeessssaa EExxtteennssiioonn PPrroojjeecctt
Milpitas Station - Montague Expressway and Capitol Avenue, Milpitas Berryessa Station - Berryessa and Mabury Roads, San Jose
Skanska/Shimmlck/Herzol JV (DBI1002F (C700))Blocka Construction Inc. Job No. 4182
Hellwig Plumbing Job No. 214-032
INDEX
Division 22 Plumbing
22 14 01 Storm Drainage
2.02 EXPOSED AND EMBEDDED DRAINAGE PIPE AND FITTINGSA. No Hub Class B Storm Drainage No Hub Pipe & Ftgs. / Std Cplgs.
A. SUBSTITUTION: Below Grade PVC-Schedule 40/DWV Ftgs
2.03 DRAINSB. Schedule (M311) RD-1 Zurn Z163
E. Schedule (M311) OFD-1 Zurn Z163
F. Schedule (M311) OFD-1, DSN-1 Zurn Z199
G. Schedule (M311) PD-1 Zurn Z348
x NO EXCEPTION TAKENMAKE CORRECTIONS NOTED
REVISE AND RESUBMITRESUBMITTAL NOT REQUIRED
SUBMITTALENGINEERS REVIEW
Engineer's review is for general conformance with the design build specifications and contract documents Markings or comments shall not be
H & M MECHANICAL GROUP
BY: DATE:
specifications and contract documents. Markings or comments shall not beconstrued as relieving the Contractor from compliance with the project plans and specifications nor departures therefrom. The Contractor remains responsible for the design and coordination with other trades.
Garry Hennings 4-10-2014
Final approval subject to BART/ VTA review and acceptance
Intentionally blank
©2012 Georg Fischer Harvel LLC • 300 Kuebler Road, Easton, PA 18040 • 610-252-7355 • Fax: 610-253-4436 • Harvel.com
Product Specifications
PVC Industrial Pipe: Schedule 80
Prod
uctS
pecif
icatio
nsPV
CSc
hedu
le80
Pipe
Application:Corrosion resistant pressure pipe, IPS sizes 1/8" through 24", for use at temperatures up to and including 140°F. Pressure rating (210 psi to 1230 psi) varies with schedule, pipe size, and temperature as stated in Georg Fischer Harvel LLC engineering bulletin (ProductBulletin 112/401). Generally resistant to most acids, bases, salts, aliphatic solutions, oxidants, and halogens. Chemical resistance data is available and should be referenced for proper material selection. Pipe exhibits excellent physical properties and flammability characteristics (independently tested flame and smoke characteristics-ULC). Typical applications include: chemical processing, plating,high purity applications, potable water systems, water and wastewater treatment, irrigation, agricultural, and other industrial applicationsinvolving corrosive fluid transfer.
Scope:This specification outlines minimum manufacturing requirements for Polyvinyl Chloride (PVC) Schedule 80 iron pipe size (IPS) pressurepipe. This pipe is intended for use in applications where the fluid conveyed does not exceed 140°F. This pipe meets and or exceeds theindustry standards and requirements as set forth by the American Society for Testing and Materials (ASTM) and the National SanitationFoundation (NSF International).
PVC Materials:The material used in the manufacture of the pipe shall be domestically produced rigid polyvinyl chloride (PVC) compound, Type I Grade I, with a Cell Classification of 12454 as defined in ASTM D1784, trade name designation H707 PVC. This compound shall be grayin color as specified, and shall be approved by NSF International for use with potable water (NSF Std 61).
Dimensions:PVC Schedule 80 pipe shall be manufactured in strict accordance to the requirements of ASTM D1785 for physical dimensions and tolerances. Each production run of pipe manufactured in compliance to this standard, shall also meet or exceed the test requirements formaterials, workmanship, burst pressure, flattening, and extrusion quality defined in ASTM D1785. All belled-end pipe shall have taperedsockets to create an interference-type fit, which meet or exceed the dimensional requirements and the minimum socket length for pressure-type sockets as defined in ASTM D2672. All PVC Schedule 80 pipe must also meet the requirements of NSF Standard 14 andCSA Standard B137.3 rigid PVC pipe for pressure applications, and shall bear the mark of these Listing agencies. This pipe shall have aflame spread rating of 0-25 when tested for surface burning characteristics in accordance with CAN/ULC-S102-2-M88 or equivalent.
Marking:Product marking shall meet the requirements of ASTM D1785 and shall include: the manufacturer’s name (or the manufacturer’s trademark when privately labeled); the nominal pipe size; the material designation code; the pipe schedule and pressure rating in psi for water @ 73°F; the ASTM designation D1785; the independent laboratory’s seal of approval for potable water usage; and the date andtime of manufacture.
Sample Specification:All PVC Schedule 80 pipe shall be manufactured from a Type I, Grade I Polyvinyl Chloride (PVC) compound with a Cell Classification of12454 per ASTM D1784. The pipe shall be manufactured in strict compliance to ASTM D1785, consistently meeting and/or exceeding theQuality Assurance test requirements of this standard with regard to material, workmanship, burst pressure, flattening, and extrusion quality. The pipe shall be manufactured in the USA, using domestic materials, by an ISO 9001 certified manufacturer. Standard lengths of pipe sizes 6" and larger shall be beveled each end by the pipe manufacturer. All pipe shall be stored indoors after production at themanufacturing site until shipped from factory. This pipe shall carry the National Sanitation Foundation (NSF) seal of approval for potablewater applications. All pipe shall be manufactured by Georg Fischer Harvel LLC.
©2012 Georg Fischer Harvel LLC • 300 Kuebler Road, Easton, PA 18040 • 610-252-7355 • Fax: 610-253-4436 • Harvel.com
Product Specifications
PVC Industrial Pipe: Schedule 80
PVC
Schedule80
PipeProductSpecifications
Schedule 80 Dimensions Nom. Pipe Average Min. Nom. Max.Size (in.) O.D. I.D. Wall Wt./Ft. W.P.
1/8 0.405 0.195 0.095 0.063 12301/4 0.540 0.282 0.119 0.105 11303/8 0.675 0.403 0.126 0.146 9201/2 0.840 0.526 0.147 0.213 8503/4 1.050 0.722 0.154 0.289 6901 1.315 0.936 0.179 0.424 6301-1/4 1.660 1.255 0.191 0.586 5201-1/2 1.900 1.476 0.200 0.711 4702 2.375 1.913 0.218 0.984 4002-1/2 2.875 2.290 0.276 1.500 4203 3.500 2.864 0.300 2.010 3703-1/2 4.000 3.326 0.318 2.452 3504 4.500 3.786 0.337 2.938 3205 5.563 4.768 0.375 4.078 2906 6.625 5.709 0.432 5.610 2808 8.625 7.565 0.500 8.522 250 10 10.750 9.493 0.593 12.635 230 12 12.750 11.294 0.687 17.384 23014 14.000 12.410 0.750 20.852 22016 16.000 14.213 0.843 26.810 22018 18.000 16.014 0.937 33.544 22020 20.000 17.814 1.031 41.047 22024 24.000 21.418 1.218 58.233 210
The pressure ratings given are for water, non-shock, @ 73°F. Thefollowing temperature de-rating factors are to be applied to theworking pressure ratings (WP) listed when operating at elevatedtemperatures.
Multiply the working pressurerating of the selected pipe at73°F, by the appropriate de-rating factor to determinethe maximum working pressurerating of the pipe at the elevated temperature chosen.
EX:10" PVC SCH 80 @ 120°F = ?230 psi x 0.40 = 92 psi max. @ 120°F
THE MAXIMUM SERVICE TEMPERATURE FOR PVC IS 140°F.
Solvent-cemented joints should be utilized when working at or near maximum temperatures. GF Harvel does not recommend the use of PVC for threaded connections at temperatures above 110°F; use flanged joints, unions, or rollgrooved couplings where disassembly is necessary at elevatedtemperatures.
Thread only Schedule 80 or heavier walls. Threading requires a 50% reduction in pressure rating stated for plain end pipe@73°F. Threading of Schedule 40 PVC pipe is not a recommendedpractice due to insufficient wall thickness.
Chemical resistance data should be referenced for proper material selection and possible de-rating when working with fluids other than water. Refer to GF Harvel 112/401 ProductBulletin for chemical resistance, installation data, and additionalinformation.
ASTM STANDARD D1784 MATERIAL EQUIVALENTS:
Cell Classification 12454 = PVC Type I Grade I = PVC1120
Pipe sizes shown are manufactured in strict compliance withASTM D1785.
De-Rating FactorOperating De-RatingTemp (°F) Factor
73 1.00 80 0.8890 0.75
100 0.62 110 0.51 120 0.40 130 0.31 140 0.22
SPEARS Schedule 80 PVC fitting designscombine years of proven experience withcomputer generated stress analysis to yieldthe optimum physical structure andperformance for each fitting. Materialreinforcement is uniformly placed in stressconcentration areas for substantiallyimproved pressure handling capability.Resulting products are subjected to numerousverification tests to assure obtaining the verybest PVC fittings available.
PVC SCHEDULE 80 FITTINGS
PROGRESSIVE PRODUCTS FROM SPEARS INNOVATION & TECHNOLOGY
Full 1/4" Through 12" AvailabilitySpears comprehensive line of injection molded PVCfittings offers a variety of configurations in moldedSchedule 80 sizes 1/4" through 12" conforming toASTM D 2467 and Spears exclusive CL150 Flangesin sizes 1/2" through 16".
Exceptional Chemical & CorrosionResistanceUnlike metal, PVC fittings never rust, scale, or pit,and will provide many years of maintenance-freeservice and extended system life.
High Temperature RatingsPVC thermoplastic can handle fluids at servicetemperatures up to 140°F (60°C), allowing a widerange of process applications, including corrosiveliquids.
Lower Installation CostsSubstantially lower material costs than steel alloysor lined steel, combined with lighter weight and easeof installation, can reduce installation costs by as
Performance Engineered & Tested80-2-0199
much as 60% over conventional metal systems.
Higher Flow CapacitySmooth interior walls result in lower pressure lossand higher volume than conventional metal fittings.
Additional Fabricated Configurationsthrough 36"Extra large, hard-to-find, and custom configurationsare fabricated from NSF Certified pipe. Fittings areengineered and tested to provide full pressure handlingcapabilities according to Spears specifications.
Advanced Design Specialty FittingsSpears wide range of innovative, improved productsinclude numerous metal-to-plastic transition fittingsand unions with Spears’ patented stainless steelreinforced (SR) plastic threads.
PVC ValvesSPEARS PVC Valve products are available for totalsystem compatibility and uniformity; see SPEARS’THERMOPLASTIC VALVES PRODUCT GUIDE &ENGINEERING SPECIFICATIONS (V-4).
Sample Engineering SpecificationsAll PVC Schedule 80 fittings shall be produced bySpears Manufacturing Company from PVC Type I,cell classification 12454, conforming to ASTMStandard D 1784. All injection molded PVCSchedule 80 fittings shall be Certified for potablewater service by NSF International andmanufactured in strict compliance to ASTM D 2467.All fabricated fittings shall be produced inaccordance with Spears General Specifications forFabricated Fittings. All PVC flanges shall be designedand manufactured to meet CL150 bolt pattern perANSI Standard B16.5 and rated for a maximuminternal pressure of 150 psi, non-shock at 73°F.
© Copyright 1999 Spears Manufacturing Company. All Rights Reserved. Printed in the United States of America 1/99. 80-2-0199
SPEARS® MANUFACTURING COMPANYCORPORATE OFFICES
15853 Olden Street, Sylmar, CA 91342P.O. Box 9203, Sylmar, CA 91392
(818) 364-1611 • http://www.spearsmfg.com
PACIFIC SOUTHWEST15860 Olden Street
Sylmar (Los Angeles), CA 91342P.O. Box 9203, Sylmar, CA 91392
(818) 364-1611(800) 862-1499
FAX: (818) 367-3014
NORTHEAST543 Industrial Drive
Lewisberry (Harrisburg), PA17339-9532
(717) 938-8844(800) 233-0275
FAX: (717) 938-6547
INTERNATIONAL SALES15853 Olden Street
Sylmar (Los Angeles), CA 91342P.O. Box 9203
Sylmar, CA 91392(818) 364-1611
FAX: (818) 898-3774E-mail: [email protected]
MIDWEST854 Fairway Drive
Bensenville (Chicago), IL60106
(630) 773-0075(800) 662-6330
FAX: (630) 773-0435
FLORIDA3445 Bartlett Boulevard
Orlando, FL32811
(407) 843-1960(800) 327-6390
FAX: (407) 425-3563
SOUTHEAST2751 Miller Road
Decatur (Atlanta), GA30035
(770) 981-7122(800) 662-6326
FAX: (770) 981-6106
UTAH1415 South 700 West #3
Salt Lake City, UT84104
(801) 972-0659FAX: (801) 972-0688
SOUTH CENTRAL1838 Forms Drive
Carrollton (Dallas), TX75006
(972) 245-0387(800) 441-1437
FAX: (972) 245-4205
ROCKY MOUNTAIN4800 Nome Street
Denver, CO80239
(303) 371-9430(800) 777-4154
FAX: (303) 375-9546
NORTHWEST3902 “B” Street N.W.Auburn (Seattle), WA
98002(253) 939-4433(800) 347-7327
FAX: (253) 939-7557
PVC Thermoplastic Pipe Temperature Pressure De-Rating
PVC Basic Physical Properties
gnitarepOmetsySerutarepmeT ° (F ° )C
37)32(
08)72(
09)23(
001)83(
011)34(
021)94(
031)45(
041)06(
CVP %001 %09 %57 %26 %05 %04 %03 %22
NOTE: Valves, Unions and Specialty Products have different elevated temperature ratings than pipe.
seitreporPMTSAtseT
dohteMCVP
37,seitreporPlacinahceM °Fmc/g,ytivarGcificepS 297D 04.1
isp,htgnertSelisneT 836D 000,7
isp,yticitsalEfosuludoM 836D 000,044
isp,htgnertSevisserpmoC 596D 000,9
isp,htgnertSlaruxelF 097D 002,31
ni/bl-tf,dehcton,tcapmIdozI 652D 56.
seitreporPlamrehT
,erutarepmeTnoitcelfeDtaeH ° isp66taF 846D 561
/tfqs/rh/UTB,ytivitcudnoClamrehT ° ni/F 771C 2.1
/ni/ni,noisnapxEraeniLfotneiciffeoC °F 696D 01x0.3 5-
ytilibammalF
%,xednInegyxOgnitimiL 3682D 34
gnitaR49LU 0-V49
seitreporPrehtO
.rh42%,noitprosbAretaW 075D 50.
roloCdradnatSyrtsudnI yarG/etihW
noitacifissalClleCMTSA 4871D 45421
devorppAretaWelbatoPFSN seY
NOT FOR USE WITHCOMPRESSED AIR OR GASES
Spears Manufacturing Company DOES NOTRECOMMEND the use of thermoplastic pipingproducts for systems to transport or storecompressed air or gases, or the testing ofthermoplastic piping systems with compressed airor gases in above and below ground locations. Theuse of our product in compressed air or gas systemsautomatically voids any warranty for such products,and its use against our recommendation is entirelythe responsibility and liability of the installer.
WARNING: DO NOT USE COMPRESSED AIR ORGAS TO TEST ANY PVC OR CPVCTHERMOPLASTIC PIPING PRODUCT OR SYSTEM,AND DO NOT USE DEVICES PROPELLED BYCOMPRESSED AIR OR GAS TO CLEAR SYSTEMS.THESE PRACTICES MAY RESULT IN EXPLOSIVEFRAGMENTATION OF SYSTEM PIPINGCOMPONENTS CAUSING SERIOUS OR FATALBODILY INJURY.
PVC Chemical ResistancePVC is generally inert to most mineral acids,bases, salts and paraffinic hydrocarbonsolutions. For more information on PVCchemical resistance refer to the ChemicalResistance of Rigid Geon® Vinyls Based onImmersion Test, published by the GEON®
company.
SUBMITTAL DATANo-Hub Pipe and Fittings
SV Hub & Spigot Pipe & FittingsAnaco Standard CouplingsHusky SD 4000 CouplingsHusky HD 2000 Couplings
Best-Set™ Closet RingsTy-Seal and EZ Tite Gaskets
Project:
Architect:
Engineer:
Contractor:
Date:
No-Hub Pipe and Fittings of 11/2” to 15” diameter. Soil waste, vent lines, rain water conductors andstorm drainage lines shall bear the registered insignia of the Cast Iron Soil Pipe Institute indicating thatthese items comply with CISPI Standard 301 or Federal Specification WW-P-401/E74, ASTM 888, asmanufactured by AB&I. IAPMO File No. 3270.
Made inUSA
7825 San Leandro Street • Oakland, CA 94621 • 800/GOT-IRON • 510/632-3467 • Fax 510/632-8035
95014 - 11/10 Rev.
Ty-Seal and EZ-Tite gaskets in sizes from 2” to 15” shall comply with all requirements of ASTM C-564.IAPMO File No. 0391.
■
■
■
■
SV Hub & Spigot Pipe and Fittings in sizes from 2” to 15”. Soil waste, vent lines, rain water conductorsand storm drainage lines shall bear the registered insignia of the Cast Iron Soil Pipe Institute indicatingthat these items comply with ASTM A-74 and HS 74. IAPMO File No. 3274.
Standard Couplings shall be made with clamp assemblies that comply with the Cast Iron Soil PipeInstitute Standard 310, with shields made from series 301 stainless steel, ASTM C-564, latest revision,as manufactured by Anaco. They shall bear either the Uniform Plumbing Code (UPC) or IAPMOtrademarks. IAPMO listed.
Husky SD 4000 Couplings shall be constructed from 304 stainless steel and provide a minimum shieldthickness of .015” or greater. Shield shall be 3” wide for sizes 11/2” through 4”, and 4” wide for 5”through 10.” Couplings shall have four sealing bands on 1 1/2 through 4” sizes, and six bands on 5”through 10” sizes. All bands shall require 80 in-lbs of torque. Gaskets shall comply with ASTM C-564.Couplings shall meet the requirements of Factory Mutual 1680 and ASTM 1277 standards. IAPMOlisted.
Husky HD 2000 Couplings shall be constructed from 304 stainless steel and provide a minimum shieldthickness of .010” or greater. Shield shall be 3” wide for sizes 11/2” through 4”, and 4” wide for 5”through 10.” Couplings shall have four sealing bands on 1 1/2 through 4” sizes, and six bands on 5”through 10” sizes. All bands shall require 80 in-lbs of torque. Gaskets shall comply with ASTM C-564.Shall meet the requirements of Factory Mutual 1680. IAPMO listed.
Best-Set™ Closet Ring is a cast iron ring manufactured by AB&I. The Best-Set features a neoprenegasket which fills the space around the pipe and the space between the pipe and the closet ring.IAPMO File No. 3209.
AB&I strongly recommends that its No-Hub cast iron pipe and fittings be joined with shielded couplings manufactured inaccordance with CISPI 310. The use of any coupling not meeting the above specifications will void the product warranty.
■
■
■
Intentionally blank
©2012 Georg Fischer Harvel LLC • 300 Kuebler Road, Easton, PA 18040 • 610-252-7355 • Fax: 610-253-4436 • Harvel.com
Product Specifications
PVC Industrial Pipe: Schedule 40
Prod
uctS
pecif
icatio
nsPV
CSc
hedu
le40
Pipe
Application:Corrosion resistant pressure pipe, IPS sizes 1/8" through 24", for use at temperatures up to and including 140°F. Pressure rating (120 psi to 810 psi) varies with schedule, pipe size, and temperature as stated in Georg Fischer Harvel LLC engineering bulletin (ProductBulletin 112/401). Pipe is also suitable for PVC plastic drain, waste, and vent (DWV) applications. Generally resistant to most acids, bases,salts, aliphatic solutions, oxidants, and halogens. Chemical resistance data is available and should be referenced for proper material selec-tion. Pipe exhibits excellent physical properties and flammability characteristics (independently tested flame and smoke characteristics-ULC). Typical applications include: chemical processing, plating, high purity applications, potable water systems, water and wastewatertreatment, drainage, irrigation, agricultural, and other applications involving corrosive fluid transfer.
Scope:This specification outlines minimum manufacturing requirements for Polyvinyl Chloride (PVC) Schedule 40 iron pipe size (IPS) pressurepipe. This pipe is intended for use in applications where the fluid conveyed does not exceed 140°F. This pipe meets and or exceeds theindustry standards and requirements as set forth by the American Society for Testing and Materials (ASTM D1785 & D2665) and theNational Sanitation Foundation (NSF International STD 61 & Std 14).
PVC Materials:The material used in the manufacture of the pipe shall be domestically produced rigid polyvinyl chloride (PVC) compound, Type I Grade I, with a Cell Classification of 12454 as defined in ASTM D1784, trade name designation H707 PVC. This compound shall be white or gray in color as specified, and shall be approved by NSF International for use with potable water (NSF Std 61).
Dimensions:All sizes of PVC Schedule 40 pipe shall be manufactured in strict accordance to the requirements of ASTM D1785 for physical dimensionsand tolerances. PVC Sch 40 pipe sizes 1-1/4" through 24" diameters shall also meet the requirements of ASTM D2665 Standard Specificationfor PVC plastic drain, waste and vent (DWV) pipe and shall be dual marked as such. Each production run of pipe manufactured in compliance to the standard, shall also meet or exceed the test requirements for materials, workmanship, burst pressure, flattening, and extrusion quality defined in ASTM D1785 and ASTM D2665 as applicable. All belled-end pipe shall have tapered sockets to create aninterference-type fit, which meet or exceed the dimensional requirements and the minimum socket length for pressure-type sockets asdefined in ASTM D2672. All PVC Schedule 40 pipe must also meet the requirements of NSF Standard 14 and CSA Standard B137.3 rigidPVC pipe for pressure applications, and shall bear the mark of these Listing agencies. This pipe shall have a flame spread rating of 0-25when tested for surface burning characteristics in accordance with CAN/ULC-S102-2-M88 or equivalent.
Marking:Product marking shall meet the requirements of ASTM D1785 and ASTM D2665 as applicable and shall include: the manufacturer’s name (or the manufacturer’s trademark when privately labeled); the nominal pipe size; the material designation code; the pipe schedule and pressure rating in psi for water @ 73°F; the ASTM designation D1785; the ASTM designation D2665 (when dual marked);the independent laboratory’s seal of approval for potable water usage; and the date and time of manufacture.
Sample Specification:All PVC Schedule 40 pipe shall be manufactured from a Type I, Grade I Polyvinyl Chloride (PVC) compound with a Cell Classification of12454 per ASTM D1784. The pipe shall be manufactured in strict compliance to ASTM D1785 and D2665 (where applicable), consistentlymeeting and/or exceeding the Quality Assurance test requirements of these standards with regard to material, workmanship, burst pressure, flattening, and extrusion quality. The pipe shall be manufactured in the USA, using domestic materials, by an ISO 9001 certified manufacturer. Standard lengths of pipe sizes 6" and larger shall be beveled each end by the pipe manufacturer. All pipe shall be stored indoors after production at the manufacturing site until shipped from factory. This pipe shall carry the National SanitationFoundation (NSF) seal of approval for potable water applications. All pipe shall be manufactured by Georg Fischer Harvel LLC.
©2012 Georg Fischer Harvel LLC • 300 Kuebler Road, Easton, PA 18040 • 610-252-7355 • Fax: 610-253-4436 • Harvel.com
Product Specifications
PVC Industrial Pipe: Schedule 40
PVC
Schedule40
PipeProductSpecifications
Schedule 40 Dimensions Nom. Pipe Average Min. Nom. Max.Size (in.) O.D. I.D. Wall Wt./Ft. W.P.
1/8 0.405 0.249 0.068 0.051 8101/4 0.540 0.344 0.088 0.086 7803/8 0.675 0.473 0.091 0.115 6201/2 0.840 0.602 0.109 0.170 6003/4 1.050 0.804 0.113 0.226 4801 1.315 1.029 0.133 0.333 450
* 1-1/4 1.660 1.360 0.140 0.450 370* 1-1/2 1.900 1.590 0.145 0.537 330* 2 2.375 2.047 0.154 0.720 280
2-1/2 2.875 2.445 0.203 1.136 300* 3 3.500 3.042 0.216 1.488 260
3-1/2 4.000 3.521 0.226 1.789 240* 4 4.500 3.998 0.237 2.118 220
5 5.563 5.016 0.258 2.874 190* 6 6.625 6.031 0.280 3.733 180* 8 8.625 7.942 0.322 5.619 160 * 10 10.750 9.976 0.365 7.966 140 * 12 12.750 11.889 0.406 10.534 130* 14 14.000 13.073 0.437 12.462 130* 16 16.000 14.940 0.500 16.286 130* 18 18.000 16.809 0.562 20.587 130* 20 20.000 18.743 0.593 24.183 120* 24 24.000 22.544 0.687 33.652 120
* Denotes these sizes are dual marked as being in compliance with both ASTM D1785 (pressurepipe) and ASTM D2665 (drain, waste & vent pipe- DWV).
The pressure ratings given are for water, non-shock, @ 73°F. The following temperature de-rating factors are to be applied to the working pressure ratings (WP) listed when operating at elevated temperatures.
Multiply the working pressurerating of the selected pipe at73°F, by the appropriate de-rating factor to determinethe maximum working pressurerating of the pipe at the elevated temperature chosen.
EX: 10" PVC SCH 40 @ 120°F = ?140 psi x 0.40 = 56 psi max. @ 120°F
THE MAXIMUM SERVICE TEMPERATURE FOR PVC IS 140°F.
Solvent-cemented joints should be utilized when working at or near maximum temperatures. GF Harvel does not recommend the use of PVC for threaded connections at temperatures above 110°F; use flanged joints, unions, or roll grooved couplings where disassembly is necessary at elevated temperatures.
Threading of Schedule 40 PVC pipe is not a recommended practice due to insufficient wall thickness. Thread only Schedule 80 or heavier walls. Threading requires a 50% reduction in pressure rating stated for plain end pipe @ 73°F.
Chemical resistance data should be referenced for proper material selection and possible de-rating when working with fluids other than water. Refer to GF Harvel 112/401 ProductBulletin for chemical resistance, installation data, and additionalinformation.
ASTM STANDARD D1784 MATERIAL EQUIVALENTS:
Cell Classification 12454 = PVC Type I Grade I = PVC1120
Pipe sizes shown are manufactured in strict compliance withASTM D1785 and ASTM D2665 where applicable.
De-Rating FactorOperating De-RatingTemp (°F) Factor
73 1.00 80 0.8890 0.75
100 0.62 110 0.51 120 0.40 130 0.31 140 0.22
Distributed by Mueller Streamline Co. • 8285 Tournament Drive, Memphis, TN 38125 • 800-348-8464 • www.muellerindustries.com page 1 of 8
Product Description:
Streamline® PVC DWV fittings for use in applications including sanitary drain, waste, and vent (DWV), sewer, and general drainage applications. Available in sizes ranging from 1-¼” to 8” in diameter, all fittings should be manufactured in the United States.
Material:
Virgin rigid polyvinyl chloride (PVC) compounds conform to cell class 12454 as defined in ASTM D1784.
Key Specifications:
Streamline® PVC DWV fittings shall be made to meet to ASTM D2665, F1498, and D3311. Third Party Certifications shall be in place for fittings in compliance with NSF Standard 14. Fittings shall be certified to the Uniform Plumbing Code (UPC) where applicable.
Installation:
Installation shall comply with the latest applicable building codes for the local jurisdiction. Solvent cement connections shall be made using a two-step process consisting of primer (in conformance with ASTM F656) and solvent cement (in conformance with ASTM D2564). For detailed installation instructions, consult the Plumbing Apprentice Training Manual available from PPFA (Plastic Pipe & Fitting Association) at ppfahome.org.
PVC DWV fittings are not designed for hot water systems but should discharge temperatures should not exceed 140°F. Systems shall be installed to avoid contact with thread sealants or other chemical agents which are not compatible with PVC. Hydrostatic testing of the system shall be completed prior to use.
Do not test or use Streamline® plastic products with compressed air or compressed gases.
References:
ASTM D1784 Standard Specification for Rigid Poly Vinyl Chloride (PVC) compoundsASTM D2665 Standard Specification for PVC drain, waste, and vent fittings ASTM F1498 Taper pipe threads for thermoplastic fittings/fitting threadsASTM D3311 Laying lengths of plastic fittings intended for use with outside diameter controlled pipes in DWV applicationASTM F656 Standard specification for primersASTM D2564 Standard specification for solvent cement
Other Applicable Standards:
CSA B181.1 ABS Drain, Waste, and Vent Pipe and Pipe FittingsNSF Standard 14 Plastic Piping System and Related ComponentsNSF International IAPMOUPC CSA
PVC DWV FITTINGS For PLUMBING AND MECHANICAL APPLICATIoNSJob Name Contractor
Job Location Wholesaler
Engineer Streamline® Rep
MadE iN USa
Distributed by Mueller Streamline Co. • 8285 Tournament Drive, Memphis, TN 38125 • 800-348-8464 • www.muellerindustries.com page 2 of 8
PVC DWV FITTINGS For PLUMBING AND MECHANICAL APPLICATIoNS
SOCKET DIMENSIONS AND TOLERANCES PVC-DWV
Trade Sizes
A B C D W R
Socket Entrance Diameter Socket Bottom DiameterMin Socket
DepthMin Internal
Thread LengthWall Thickness
Min.Radius or
45° ChamferTotal Average Tol. A Out of Round Total Average
Tol. A Out of Round
1-1/4” 1.675 0.024 1.655 0.024 0.687 0.687 0.156 1/16
1-1/2” 1.915 0.024 1.894 0.024 0.687 0.687 0.156 1/16
2” 2.390 0.024 2.639 0.024 0.750 0.750 0.156 3/32
3” 3.520 0.030 3.492 0.030 1.500 1.187 0.219 1/8
4” 4.520 0.030 4.491 0.030 1.750 1.281 0.250 1/8
6” 6.647 0.060 6.614 0.060 3.000 1.500 0.281 1/8
8” 8.655 0.090 8.610 0.090 4.000 1.687 0.328 3/16
Note: “A” Tolerance through 4” + 0.010, -0.005. 6” +0.015, -0.010, 8” +0.030, -0.000 “B” Tolerance 1-1/4” ±0.005, 1-1/2” & 2” ±0.006, 3” ±0.008, 4” ±0.009, 6” ±0.011, 8” ±0.015
SIZING NOMENCLATURE FOR DWV FITTINGSMulti-Joint Fittings
1 = Bottom Outlet2 = Top Inlet3 = Main Branch4 = Branch, Side Inlet
Two Joint Fittings
1 = Left Side of Fitting2 = Right Side of Fitting
CONNECTION DESCRIPTIONSH Hub
Sp Spigot (Pipe O.D.)
SJ Slip Joint
MPT Male Pipe Thread
FPT Female Pipe Thread
S/D Sewer & Drain
NPSM National Pipe Straight Mechanical Thread
CI Cast Iron
All 90° Openings Pitch 1/4” Per Foot(Exception - Vent Fittings)
Distributed by Mueller Streamline Co. • 8285 Tournament Drive, Memphis, TN 38125 • 800-348-8464 • www.muellerindustries.com page 3 of 8
PLASTIC FITTINGS – PLUMBINGPVC DWV
STYLE NO. P100COUPLING
H x H
Size Part # Ctn Plt1 1/4 05932 100 7,2001 1/2 05933 100 7,200 2 05934 100 4,8003 05935 60 1,4404 05936 25 7006 06143 15 1808 06145 4 80 STYLE NO. P101FEMALE ADAPTER
FPT x H
Size Part # Ctn Plt1 1/4 05868 50 4,5001 1/2 05866 100 7,200 2 05867 100 4,800 3 05869 30 1,2604 06396 10 7206 06147 10 240 STYLE NO. P102PIPE INCREASER / REDUCER
H x H
Size Part # Ctn Plt1 1/2 x 2 05948 25 3,600 1 1/2 x 3 05949 25 1,800 2 x 3 05950 20 1,440 2 x 4 05951 10 720 3 x 4 05952 20 8404 x 6 05981 5 270
STYLE NO. P103PTRAP ADAPTER, MALE, W / 1 PIECE POLY NUT SP x SJ
Size Part # Ctn Plt1 1/4 06309 50 7,200 1 1/2 06393 50 5,4001 1/2 x 1 1/4 06379 75 5,400 STYLE NO. P103RTRAP ADAPTER, MALE, W / PLASTIC NUT & 1 1/2 x 1 1/4 WASHERSP x SJ
Size Part # Ctn Plt1 1/2 x 1 1/4 06389 50 5,400 1 1/2 06389 50 5,400
STYLE NO. P103WTRAP ADAPTER, MALE, W / PLASTIC NUT AND WASHER
SP x SJ
Size Part # Ctn Plt1 1/4 06308 50 7,2001 1/2 06410 50 5,400 2 06390 25 3,6001 1/2 x 1 1/4 06409 50 5,400
STYLE NO. P103XTRAP ADAPTER, MALE, W / CHROME NUT & WASHER
SP x SJ
Size Part # Ctn Plt1 1/2 06392 50 5,4001 1/2 x 1 1/4 06378 100 7,200
STYLE NO. P104PTRAP ADAPTER, FEMALE, W / 1 PIECE POLY NUT H x SJ
Size Part # Ctn Plt1 1/4 06381 50 7,2001 1/2 06377 50 5,4001 1/2 x 1 1/4 06395 50 5,400
STYLE NO. P104WTRAP ADAPTER, FEMALE, W / PLASTIC NUT AND WASHER
H x SJ
Size Part # Ctn Plt1 1/4 06380 50 7,2001 1/2 06383 50 5,400 2 06382 25 3,600 1 1/2 x 1 1/4 06384 50 5,400 STYLE NO. P104XTRAP ADAPTER, FEMALE, W / CHROME NUT & WASHERH x SJ
Size Part # Ctn Plt1 1/2 06376 50 5,4002 06397 25 3,6001 1/2 x 1 1/4 06394 50 5,400
STYLE NO. P105FITTING CLEANOUT ADAPTER
SP x FPT
Size Part # Ctn Plt1 1/4 05918 50 7,2001 1/2 05922 50 7,200 2 05923 50 3,600 3 05924 25 1,3504 05925 10 720 6 06148 10 240
STYLE NO. P105XFITTING CLEANOUT ADAPTER, W / CLEANOUT PLUG SP x FPT
Size Part # Ctn Plt1 1/4 06007 50 7,200 1 1/2 06001 50 5,400 2 06002 50 3,6003 06003 25 1,200 4 06004 10 5406 06005 10 180
STYLE NO. P106CLEANOUT PLUG
MPT
Size Part # Ctn Plt1 1/4 05937 100 14,400 1 1/2 05938 50 7,2002 05939 50 7,200 3 05941 25 3,600 4 05942 30 2,160 6 06146 10 720 STYLE NO. P106PSLIP PLUG SP
Size Part # Ctn Plt1 1/2 06055 25 3,600 2 06056 50 7,200 STYLE NO. P107FLUSH BUSHING
SP x H STYLE #3
Size Part # Ctn Plt1 1/2 x 1 1/4 05904 100 14,400 2 x 1 1/4 05905 50 7,2002 x 1 1/2 05906 50 7,2003 x 1 1/2 05907 30 3,2403 x 2 05908 30 3,2404 x 2 05910 30 1,4404 x 3 05909 30 1,620
STYLE NO. P107SFLANGE BUSHING, W / TUBE STOP SP x H STYLE #1
Size Part # Ctn Plt6 x 4 06144 10 3608 x 6 06149 4 128 STYLE NO. P108FLUSH BUSHING
SP x FPT STYLE #1
Size Part # Ctn Plt
2 x 1 1/2 05913 50 7,200 STYLE NO. P109MALE ADAPTER
H x MPT
Size Part # Ctn Plt1 1/4 05931 50 4,500 1 1/2 05927 50 7,2002 05928 50 3,600 3 05929 25 1,8004 05930 25 900
REDUCING
1 1/4 x 1 1/2 05926 25 3,600
Distributed by Mueller Streamline Co. • 8285 Tournament Drive, Memphis, TN 38125 • 800-348-8464 • www.muellerindustries.com page 4 of 8
STYLE NO. P110FLUSH CLEANOUT PLUG
MPT
Size Part # Ctn Plt4 06015 25 3,6002 06017 25 7,2003 06018 50 7,200
STYLE NO. P111MALE FITTING ADAPTER
SP x MPT
Size Part # Ctn Plt1 1/4 06010 50 7,2001 1/2 06386 50 5,4002 06385 25 3,600 3 06366 25 1,350
REDUCING
1 1/2 x 1 1/4 06387 100 7,200
STYLE NO. P113TRAY PLUG ADAPTER
H x NPSM THREAD
Size Part # Ctn Plt1 1/2 06014 50 3,600
STYLE NO. P113STRAY PLUG ADAPTER, SPIGOT
SP x NPSM
Size Part # Ctn Plt1 1/2 06419 50 2,700
STYLE NO. P114THREADED CAP
FPT
Size Part # Ctn Plt1 1/2 05993 100 9,0002 05994 50 7,200
STYLE NO. P116SOCKET CAP
H
Size Part # Ctn Plt1 1/2 05977 50 7,2002 05978 25 3,6003 05979 25 1,8004 05980 5 7206 06057 5 360 8 06058 3 108
STYLE NO. P117ADAPTER COUPLING
S/D H x DWV H (ADAPTS SEWER & DRAIN PIPE TO DWV PIPE)
Size Part # Ctn Plt3 05970 10 7204 05963 10 480 4 x 3 05962 20 960
STYLE NO. P117XADAPTER COUPLING, S/D X DWV HUBS/D SP x DWV H (Adapts 4” S/D HUB TO 3” DWV Spigot PIPE)
Size Part # Ctn Plt4 x 3 05992 10 720
STYLE NO. P118ADAPTER BUSHING
DWV SP x SD H (Adapts DWV Hub to S/D Spigot)
Size Part # Ctn Plt3 05990 25 2,7004 05991 10 1,440 STYLE NO. P119NO HUB ADAPTER
NO H x H (Adapts CI NO HUB TO DWV PIPE)
Size Part # Ctn Plt1 1/2 05802 25 3,600 2 05954 25 3,600 3 05955 20 1,4404 05956 15 8104 x 3 05953 10 480
STYLE NO. P120 SCH 40 TO SCH 30 ADAPTER
(ADAPTS 3” SCH 30. HUB TO 3” PVC SCH 40)
Size Part # Ctn Plt3 05996 20 1,440
STYLE NO. P122 SPIGOT ADAPTER, CAST IRON
ALL HUB (ADAPTS CI SPIGOT TO DWV PIPE)
Size Part # Ctn Plt2 05944 50 3,6004 05946 10 320 STYLE NO. P123 HUB ADAPTER, CAST IRON
SP x H (ADAPTS CI HUB TO DWV PIPE)
Size Part # Ctn Plt2 05957 20 1,4403 05958 20 840 4 05959 20 480
STYLE NO. P123R HUB ADAPTER, CAST IRON, INCREASER SP x H (ADAPTS CI HUB TO DWV PIPE)
Size Part # Ctn Plt2 x 1 1/2 05961 10 1,440 3 x 1 1/2 05964 10 7203 x 2 06398 20 1,0804 x 3 05960 10 480
STYLE NO. P130REPAIR COUPLING
H x H
Size Part # Ctn Plt1 1/2 05965 20 4,8002 05966 25 3,6003 05967 10 1,0804 05968 5 540 6 05969 5 175
STYLE NO. P140SLIP JOINT NUT
Size Part # Ctn Plt1 1/4 05743 400 21,6001 1/2 05744 100 14,4002 05741 100 10,800
STYLE NO. P1421 PIECE POLY NUT
Size Part # Ctn Plt1 1/4 01036 150 21,600 1 1/2 01038 125 18,000
STYLE NO. P3001/4 BEND H x H
Size Part # Ctn Plt1 1/4 05875 50 3,0001 1/2 05876 100 3,2002 05877 50 1,8003 05878 25 4504 05879 10 2406 06130 5 808 06131 2 32 STYLE NO. P300R1/4 BEND
H x H
Size Part # Ctn Plt2 x 1 1/2 06092 10 1,440
STYLE NO. P300S1/4 BEND, W / SIDE INLET
H x H
Size Part # Ctn Plt3 x 3 x 1 1/2 06069 10 3603 x 3 x 2 06070 10 360 STYLE NO. P3021/4 BEND, STREET
SP x H
Size Part # Ctn Plt1 1/4 05894 50 3,0001 1/2 05880 100 3,6002 05881 50 1,8003 05882 20 5604 05883 10 2406 05889 5 80
STYLE NO. P3031/4 BEND, W / LOW HEEL INLET
H x H
Size Part # Ctn Plt3 x 3 x 1 1/2 06041 25 4503 x 3 x 2 06042 25 4504 x 4 x 2 06043 15 180 STYLE NO. P304LONG SWEEP 1/4 BEND
H x H
Size Part # Ctn Plt1 1/2 05871 50 1,8002 05872 25 1,2003 05873 10 360 4 05874 5 180 STYLE NO. P305 LONG SWEEP 1/4 BEND W / HIGH HEEL INLET H x H
Size Part # Ctn Plt3 x 3 x 1 1/2 06028 10 3603 x 3 x 2 06027 25 400
Distributed by Mueller Streamline Co. • 8285 Tournament Drive, Memphis, TN 38125 • 800-348-8464 • www.muellerindustries.com page 5 of 8Distributed by Mueller Streamline Co. • 8285 Tournament Drive, Memphis, TN 38125 • 800-348-8464 • www.muellerindustries.com
STYLE NO. P307 LONG SWEEP 1/4 BEND W / LOW HEEL INLET H x H
Size Part # Ctn Plt3 x 3 x 1 1/2 06025 10 360 3 x 3 x 2 06024 25 300
STYLE NO. P309 LONG SWEEP 1/4 BEND, STREET
SP x H
Size Part # Ctn Plt1 1/2 06060 50 2,4002 06061 25 1,200 3 06063 20 360 4 06064 10 160 STYLE NO. P310 1/4 BEND W / LOW HEEL INLET
H x H x SP
Size Part # Ctn Plt3 x 3 x 2 06026 15 420 91.78
STYLE NO. P311LONG SWEEP 1/4 BEND W / SIDE INLET H x H
Size Part # Ctn Plt3 x 3 x 2 06050 25 400
STYLE NO. P3191/6 BEND
H x H
Size Part # Ctn Plt1 1/2 05895 40 2,880 2 05896 25 1,8003 05897 20 3204 05982 10 320
STYLE NO. P320 1/6 BEND, STREET
SP x H
Size Part # Ctn Plt1 1/2 06020 50 3,000 2 06021 20 1,8003 06022 20 640 4 06023 5 160 STYLE NO. P3211/8 BEND
H x H
Size Part # Ctn Plt1 1/4 05884 50 3,600 1 1/2 05885 100 3,6002 05886 50 1,8003 05887 20 6404 05888 10 2806 06132 3 968 06134 3 48 STYLE NO. P3231/8 BEND, STREET
SP x H
Size Part # Ctn Plt1 1/4 06016 50 3,6001 1/2 05890 100 3,6002 05891 50 1,8003 05892 20 7204 05893 10 320 6 06133 3 96 8 06136 3 48
STYLE NO. P324 1/16 BEND
H x H
Size Part # Ctn Plt1 1/2 05899 50 3,600 2 05900 25 2,700 3 05901 20 7204 05983 15 4206 05988 3 108 STYLE NO. P3261/16 BEND, STREET
SP x H
Size Part # Ctn Plt1 1/2 05984 50 5,4002 05985 25 2,700 3 05986 20 960 4 05987 10 360 6 06011 5 90
STYLE NO. P327DOUBLE 1/4 BEND
H x H
Size Part # Ctn Plt1 1/2 06045 20 1,4402 06046 25 9003 06047 10 2804 06048 5 100
REDUCING2 x 1 1/2 x 1 1/2 06049 25 1,200
STYLE NO. P329 CLOSET BEND, REDUCING
H x H
Size Part # Ctn Plt44 x 3 06093 10 360
STYLE NO. P330 CLOSET BEND, REDUCING
H x S
Size Part # Ctn Plt4 x 3 06107 10 280
STYLE NO. P330X CLOSET BEND, REDUCING, W / TEST CAP H x S
Size Part # Ctn Plt4 x 3 06108 10 280
STYLE NO. P331 VENT ELL
H x H
Size Part # Ctn Plt1 1/2 06084 20 2,880 2 06085 30 1,620 3 06086 25 700 STYLE NO. P333 VENT ELL, STREET
H x SP
Size Part # Ctn Plt1 1/2 06088 25 3,6002 06089 20 1,440 3 06090 10 540
STYLE NO. P400 SANITARY TEE
ALL HUB
Size Part # Ctn Plt1 1/4 05751 50 2,000 1 1/2 05752 100 1,8002 05753 35 1,120 3 05754 30 360 4 05755 5 140 6 05756 5 60 8 05775 1 30 STYLE NO. P401 SANITARY TEE, REDUCING
ALL HUB
Size Part # Ctn Plt1 1/2 x 1 1/2 x 1 1/4 05757 20 1,4402 x 1 1/2 x 1 1/2 05761 25 1,350 2 x 1 1/2 x 2 05760 25 1,2002 x 2 x 1 1/2 05758 50 1,2003 x 3 x 1 1/2 05764 20 640 3 x 3 x 2 05763 10 4804 x 4 x 1 1/2 05767 5 3604 x 4 x 2 05765 10 2804 x 4 x 3 05766 10 1806 x 6 x 4 05768 5 60 STYLE NO. P403 SANITARY TEE, STREET
SP x H x H
Size Part # Ctn Plt1 1/2 06112 20 2,160 2 06113 25 1,200 3 06114 30 360 4 06120 10 180 STYLE NO. P404 SANITARY TEE, STREET, REDUCING SP x H x H
Size Part # Ctn Plt2 x 1 1/2 x 1 1/2 06115 25 1,350 2 x 1 1/2 x 2 06116 25 1,3502 x 2 x 1 1/2 06117 50 1,600 3 x 3 x 1 1/2 06118 10 5403 x 3 x 2 06119 20 5604 x 4 x 2 06121 5 270
STYLE NO. P416 SANITARY TEE W / LEFT SIDE INLET ALL HUB
Size Part # Ctn Plt3 x 3 x 3 x 1 1/2 05781 10 280 3 x 3 x 3 x 2 05782 10 2804 x 4 x 4 x 2 05784 5 120
STYLE NO. P417 SANITARY TEE W / RIGHT SIDE INLET ALL HUB
Size Part # Ctn Plt3 x 3 x 3 x 1 1/2 05795 10 2803 x 3 x 3 x 2 05796 10 280 4 x 4 x 4 x 2 05797 5 100
Distributed by Mueller Streamline Co. • 8285 Tournament Drive, Memphis, TN 38125 • 800-348-8464 • www.muellerindustries.com page 6 of 8
STYLE NO. P418 SANITARY TEE W / RIGHT & LEFT SIDE INLET ALL HUB
Size Part # Ctn Plt List3 x 3 x 3 x 1 1/2 x 1 1/2 05810 10 2403 x 3 x 3 x 2 x 2 05811 5 2104 x 4 x 4 x 1 1/2 x 1 1/2 05805 5 1204 x 4 x 4 x 2 x 2 05808 5 100
STYLE NO. P428 DOUBLE SANITARY TEE
ALL HUB
Size Part # Ctn Plt1 1/2 05812 25 1,3502 05813 20 7203 05814 20 2404 05815 4 112 STYLE NO. P429 DOUBLE SANITARY TEE, REDUCING ALL HUB
Size Part # Ctn Plt2 x 2 x 1 1/2 x 1 1/2 05817 20 8403 x 3 x 1 1/2 x 1 1/2 05818 20 480 3 x 3 x 2 x 2 05820 10 3604 x 4 x 2 x 2 05240 5 240 4 x 4 x 3 x 3 05821 5 160
STYLE NO. P431 DOUBLE SANITARY TEE, STREET, REDUCING SP x H x H x H
Size Part # Ctn Plt3 x 3 x 2 x 2 06310 10 360
STYLE NO. P438 DOUBLE SANITARY TEE W / SIDE INLET ALL HUB
Size Part # Ctn Plt3 x 3 x 3 x 3 x 2 05772 10 180
STYLE NO. P439 DOUBLE SANITARY TEE W / RIGHT & LEFT SIDE INLET ALL HUB
Size Part # Ctn Plt3 x 3 x 3 x 3 x 2 x 2 05770 10 180
STYLE NO. P441 VENT TEE
ALL HUB
Size Part # Ctn Plt1 1/2 06403 25 1,8002 06404 25 1,3503 06405 10 480 4 06406 5 180 STYLE NO. P444XCLEANOUT TEE WITH PLUG
H x H x FPT
Size Part # Ctn Plt1 1/2 05997 10 1,4402 05998 10 1,0803 05999 10 4804 06000 5 180
STYLE NO. P445 FLUSH CLEANOUT TEE
H x H x FPT
Size Part # Ctn Plt1 1/2 06413 20 2,1602 06414 20 1,440 3 06415 10 540 4 06416 10 240
STYLE NO. P445 XFLUSH CLEANOUT TEEW/ PLUG
H x H x FPT
Size Part # Ctn Plt2 05198 10 1,4403 05199 10 360 4 05200 5 180
STYLE NO. P447 HORIZONTAL TWIN TEE
ALL HUB
Size Part # Ctn Plt3 x 3 x 1 1/2 x 1 1/2 05235 5 400
STYLE NO. P448 TWO-WAY CLEANOUT
ALL HUB
Size Part # Ctn Plt3 05237 10 240 4 05238 5 120
STYLE NO. P500 DOUBLE FIXTURE FITTINGALL HUB
Size Part # Ctn Plt2 05246 25 5003 05249 5 135 2 x 1 1/2 x 1 1/2 x 1 1/2 05247 20 840 2 x 2 x 1 1/2 x 1 1/2 05244 20 7203 x 2 x 3 x 3 05250 5 135
STYLE NO. P501 COMBINATION WYE & 1/8 BEND – ONE PIECE ALL HUB
Size Part # Ctn Plt1 1/2 05853 50 1,2002 05858 20 560 3 05852 10 2404 05860 10 120
STYLE NO. P502 COMBINATION WYE & 1/8 BEND, REDUCING – ONE PIECE ALL HUB
Size Part # Ctn Plt2 x 1 1/2 x 1 1/2 05835 5 5402 x 1 1/2 x 2 05836 5 540 2 x 2 x 1 1/2 05865 20 840 3 x 3 x 1 1/2 05837 15 480 3 x 3 x 2 05857 10 360 4 x 4 x 2 05863 5 180 4 x 4 x 3 05864 5 140
STYLE NO. P503 COMBINATION WYE & 1/8 BEND – TWO PIECE ALL HUB
Size Part # Ctn Plt6 05266 2 24 STYLE NO. P504 COMBINATION WYE & 1/8 BEND, REDUCING – TWO PIECE ALL HUB
Size Part # Ctn Plt6 x 6 x 4 05267 4 486 x 6 x 3 05271 5 40
STYLE NO. P507 DOUBLE COMBINATION WYE & 1/8 BEND, ASSEMBLED ALL HUB
Size Part # Ctn Plt3 06032 10 120 4 06033 4 48 2 x 1 1/2 06034 10 490 3 x 2 06035 10 180 4 x 2 06036 5 90 4 x 3 06037 5 40
STYLE NO. P515 COMBO WYE & 1/8 BEND W / LEFT SIDE INLET ALL HUB
Size Part # Ctn Plt3 x 3 x 3 x 2 06009 10 180
STYLE NO. P516 COMBO WYE & 1/8 BEND W / RIGHT SIDE INLET ALL HUB
Size Part # Ctn Plt3 x 3 x 3 x 2 06008 10 180
STYLE NO. P600 WYE ALL HUB
Size Part # Ctn Plt1 1/4 05816 35 1,6801 1/2 05822 50 1,4002 05823 25 800 3 05824 25 300 4 05825 5 1406 06135 4 48 8 06139 1 12
STYLE NO. P601WYE, REDUCING ALL HUB
Size Part # Ctn Plt2 x 1 1/2 x 1 1/2 05831 25 1,0502 x 1 1/2 x 2 05832 50 9002 x 2 x 1 1/2 05826 25 1,0503 x 3 x 1 1/2 05827 15 4203 x 3 x 2 05828 25 400 4 x 4 x 1 1/2 05833 5 2104 x 4 x 2 05829 10 240 4 x 4 x 3 05830 10 160 6 x 6 x 3 06138 5 60 6 x 6 x 4 06137 5 608 x 8 x 6 05834 1 16
STYLE NO. P602 WYE, STREET
SP x H x H
Size Part # Ctn Plt1 1/2 06367 50 1,800 2 06368 30 960 3 06369 10 360 4 06370 5 140
Distributed by Mueller Streamline Co. • 8285 Tournament Drive, Memphis, TN 38125 • 800-348-8464 • www.muellerindustries.com page 7 of 8
STYLE NO. P603WYE, STREET, REDUCING
SP x H x H
Size Part # Ctn Plt3 x 3 x 1 1/2 06372 20 480 3 x 3 x 2 06373 30 4804 x 4 x 2 06374 10 2404 x 4 x 3 06375 10 180
STYLE NO. P611DOUBLE WYE
ALL HUB
Size Part # Ctn Plt1 1/2 05838 40 1,120 2 05839 20 560 3 05840 10 1604 05841 5 80 6 05842 2 24
STYLE NO. P611SDOUBLE WYE W / SIDE INLET
ALL HUB
Size Part # Ctn Plt3 x 3 x 3 x 3 x 2 05849 10 1604 x 4 x 4 x 4 x 2 06159 5 60
STYLE NO. P612DOUBLE WYE, REDUCING
ALL HUB
Size Part # Ctn Plt2 x 2 x 1 1/2 x 1 1/2 05847 10 7203 x 3 x 1 1/2 x 1 1/2 05843 10 360 3 x 3 x 2 x 2 05844 10 2804 x 4 x 2 x 2 05845 5 1804 x 4 x 3 x 3 05846 5 90 6 x 6 x 4 x 4 06142 3 54
STYLE NO. P625 WYE W / LEFT SIDE INLET
ALL HUB
Size Part # Ctn Plt3 x 3 x 3 x 2 06155 5 175 4 x 4 x 4 x 2 06157 5 90
STYLE NO. P626 WYE W / RIGHT SIDE INLET
ALL HUB
Size Part # Ctn Plt3 x 3 x 3 x 2 06156 5 1754 x 4 x 4 x 2 06158 5 90 STYLE NO. P700 RETURN BEND
H x H
Size Part # Ctn Plt1 1/2 06466 20 1,440 2 06467 35 8403 06468 10 280 4 06469 5 120
STYLE NO. P701 RETURN BEND W / CLEANOUT
H x H
Size Part # Ctn Plt1 1/2 06471 20 1,4402 06472 10 720
STYLE NO. P704PTAIL PIECE ADAPTER (Plastic Nut)
SP x SJ (FINISHED W/BOTH SIZES SJ WASHERS)
Size Part # Ctn Plt1 1/2 x 1 1/4 05975 25 2,7001 1/2 05975 25 2,700
STYLE NO. P706XP-TRAP W / SOLVENT WELD JOINT
H x H
Size Part # Ctn Plt1 1/2 05214 25 1,2002 05222 20 5603 05230 10 1804 05231 4 96 STYLE NO. P707XP-TRAP W / SOLVENT WELD JOINT & CLEAN OUT H x H
Size Part # Ctn Plt1 1/2 05223 10 1,0802 05224 10 540
STYLE NO. P708P P-TRAP W / UNION
H x H
Size Part # Ctn Plt1 1/4 05921 50 1,3501 1/2 05215 25 900 2 05216 20 480 STYLE NO. P710 P-TRAP LOW PROFILE
H x H
Size Part # Ctn Plt2 05225 20 720 STYLE NO. P711PLA P-TRAP W / UNION & 1 1/2 x 1 1/4 NUT & POLY WASHER SJ x H (FURNISHED W/BOTH SIZE SJ WASHERS)
Size Part # Ctn Plt1 1/4 x 1 1/2 05220 25 9001 1/2 05220 25 900
STYLE NO. P720XDRUM TRAP, W / CLEANOUT H x H (W/PLUG)
Size Part # Ctn Plt3 x 6 x 1 1/2 06100 10 320
STYLE NO. P800CLOSET FLANGE
H (ONE PIECE WITH SLOTS)
Size Part # Ctn Plt4 x 4 05902 25 700
STYLE NO. P800SCLOSET FLANGE, W / STOP (ONE PIECE WITH SLOTS)
Size Part # Ctn Plt4 x 3 05903 25 700
STYLE NO. P800KOCLOSET FLANGE, KNOCK OUT H (ONE PIECE WITH SLOTS & KNOCK OUT TEST CAP)
Size Part # Ctn Plt4 x 3 05254 25 7004 x 4 05253 25 700
STYLE NO. P801 CLOSET FLANGE, SPIGOT, REDUCING SP (ONE PIECE PLASTIC)
Size Part # Ctn Plt4 x 3 05919 25 800
STYLE NO. P810 CLOSET FLANGE, ADJUSTABLE, W / PLASTIC RING H (W / SLOTS)
Size Part # Ctn Plt4 x 4 05256 25 700
STYLE NO. P810SCLOSET FLANGE, W / STOP, ADJUSTABLE, W / PLASTIC RINGH (W / SLOTS)
Size Part # Ctn Plt4 x 3 05251 25 700 STYLE NO. P811 CLOSET FLANGE, ADJUSTABLE, W / METAL RING, EPOXY COATEDH (W / SLOTS)
Size Part # Ctn Plt4 x 3 05227 25 700 4 x 4 05226 25 700
STYLE NO. P812 CLOSET FLANGE, SPIGOT, ADJUSTABLE, W / METAL RING, EPOXY COATEDSP
Size Part # Ctn Plt4 x 3 05228 25 7004 x 4 05229 25 700
STYLE NO. P812PCLOSET FLANGE, SPIGOT, ADJUSTABLE, W / PLASTIC RING SP
Size Part # Ctn Plt4 x 3 05252 25 700 4 x 4 05264 25 700
Distributed by Mueller Streamline Co. • 8285 Tournament Drive, Memphis, TN 38125 • 800-348-8464 • www.muellerindustries.com page 8 of 8
STYLE NO. P815 FLUSH CLOSET FLANGE
H (FITS OVER 3” OR INSIDE 4” SCH 40 DWV PIPE)
Size Part # Ctn Plt4 x 4 / 4 x 3 05255 25 700
STYLE NO. P815KOFLUSH CLOSET FLANGE, KNOCK OUT H (FITS OVER 3” OR INSIDE 4” SCH 40 DWV PIPE)
Size Part # Ctn Plt4 x 4 / 4 x 3 05257 25 700
STYLE NO. P820 OFFSET CLOSET FLANGE, ADJUSTABLE, W / METAL RING, EPOXY COATEDH
Size Part # Ctn Plt4 x 3 05920 15 540
Z163 015 [381] COMBINATION MAIN ROOF &
OVERFLOW DRAIN WI LOW SILHOUETTE DOMES & DOUBLE TOP-SET® DECK PLATE
SPECIFICATION SHEET
TAG RD- I Dimensional Data (inches and [mm]) are Subject to Manufacturing Tolerances and Change Without Notice
1---------48 [1219J X 24 [6 10J--------1
12 [ 305J~i__---24 [610J----------i
Approx .
~A---l 01 1~ [292J
t---01 6~ [419 J---1
ENGINEERING SPECIFICATION: ZURN Z163 A - Pipe Size In . WI. Lbs .
Dome Open Area Sq. In . [cm2] 15 [381] Diameter roof drain and overflow drain, Dura-Coated cast iron
bodies with combination membrane flashing clamp/gravel guards, double
Top-Set® deck plate, and low silhouette Poly-Domes.
[kg]
1\ 2-3-4[51-76-102] 36 [16]
5-6[127-152] 37 [17] 103 [665] 38 [17]
OPTIONS (Check/specify appropriate options) 8 [203]
PIPE SIZE (Specify size/type) OUTLET E BODY HT. DIM.
2 thru 6, 8 [51 thru 152, 203] 2 thru 6, 8 [51 thru 152, 203] 2 thru 6, 8 [51 thru 152, 203]
------:r-2,3,4 [51,76,102]
PREFIXES Z ZA ZC ZRB
SUFFIXES -AR -BS -DE -DR
D.C.C.I. Body with Poly-Dome* D.C.C.I. Body with Aluminum Dome D.C.C.I. Body with Cast Iron Dome D.C.C.I. Body with Plain Bronze Dome
Acid Resistant Epoxy Coated Finish Bronze Mesh Screen Over Dome Deck Extension Top-Set® Drain Riser
IC IP NH NL
-E -EA
Static Extension 1 thru 4 [25 thru 102] (Specify Ht.) Adjustable Extension Assembly
-G -GD -HD
-SC -SS
2-1/8 thru 3-1/2 [54 thru 89] Galvanized Cast Iron Galvanized Cast Iron Dome 6-3/4 [171] High Aluminum Dome Strainer (148 sq. in. [955 cm2] Open Area)(ZA Only) Secondary Clamping Collar Stainless Steel Mesh Screen Over Dome
*REGULARL Y FURNISHED UNLESS OTHERWISE SPECIFIED
Inside Caulk 5-1/4 [133] Threaded No-Hub Neo-Loc
REV.D
3-3/4 [95] 5-1/4 [133] 4-5/8 [117]
-TC Neo-Loc Test Cap Gasket (2-4 [51-102] NL Bottom Outlet Only)
-VP Vandal Proof Secured Top -W3 3 [76] Internal Water Dam -W4 4 [1 02] Internal Water Dam -XJ Vertical Expansion Joint (See Z190) -84 Stainless Steel Perforated Gravel Guard -85 Stainless Steel Perforated Extension -89 2 [51] High External Water Dam
(Replaces Internal Dam)
DATE: 08/09/12 C.N. NO. 124643
DWG . NO. 67201 PRODUCT NO. Z163 ZURN INDUSTRIES, LLC. + SPECIFICATION DRAINAGE OPERATION + 1801 Pittsburgh Ave. + Erie, PA 16514
Phone: 814/455-0921 • Fax: 814/454-7929 + World Wide Web: www.zurn.com In Canada: ZURN INDUSTRIES LIMITED. 3544 Nashua Drive . Mississauga, Ontario L4V1L2 • Phone: 905/405-8272 Fax: 905/405·1292
Intentionally blank
Z163 015 [381] COMBINATION MAIN ROOF &
OVERFLOW DRAIN WI LOW SILHOUETTE DOMES & DOUBLE TOP-SET® DECK PLATE
SPECIFICATION SHEET
TAG OrQ-l Dimensional Data (inches and [mm]) are Subject to Manufacturing Tolerances and Change Without Notice
1---------48 [1 219 J X 24 [61 0 J------------I
-12 [305J-i---------24 [610J------;
Approx.
~-A-j
¢11~ [292J
01 6~ [41 9 J ----I
ENGINEERING SPECIFICATION: ZURN Z163 A - Pipe Size In . WI. Lbs .
Dome Open Area Sq. In. [cm2] 15 [381] Diameter roof drain and overflow drain, Dura-Coated cast iron
bodies with combination membrane flashing clamp/gravel guards, double Top-Set® deck plate, and low silhouette Poly-Domes.
\ [kg]
2-3-4 [51-76-1 02] 36 [16]
5-6 [127 -152] 37 [17] 103 [665] 38 [17]
OPTIONS (Check/specify appropriate options) 8 [203]
PIPE SIZE (Specify size/type) OUTLET E BODY HT. DIM.
2 thru 6, 8 [51 thru 152, 203] 2 thru 6, 8 [51 thru 152, 203] 2 thru 6, 8 [51 thru 152, 203] 2, 3,4 [51, 76, 102]
PREFIXES Z ZA ZC ZRB
SUFFIXES -AR -BS -DE -DR
D.C.C.1. Body with Poly-Dome* D.C.C.1. Body with Aluminum Dome D.C.C.1. Body with Cast Iron Dome D.C.C.1. Body with Plain Bronze Dome
Acid Resistant Epoxy Coated Finish Bronze Mesh Screen Over Dome Deck Extension Top-Set® Drain Riser
IC IP NH NL
-E -EA
Static Extension 1 thru 4 [25 thru 102] (Specify Ht.) Adjustable Extension Assembly
-G -GO -HD
-SC -SS
2-1/8 thru 3-1/2 [54 thru 89] Galvanized Cast Iron Galvanized Cast Iron Dome 6-3/4 [171] High Aluminum Dome Strainer (148 sq. in. [955 cm2] Open Area)(ZA Only) Secondary Clamping Collar Stainless Steel Mesh Screen Over Dome
*REGULARL Y FURNISHED UNLESS OTHERWISE SPECIFIED
Inside Caulk 5-1/4[133] Threaded No-Hub Neo-Loc
REV.D
3-3/4 [95] 5-1/4 [133] 4-5/8 [117]
-TC Neo-Loc Test Cap Gasket (2-4 [51-102] NL Bottom Outlet Only)
-VP Vandal Proof Secured Top -W3 3 [76] Internal Water Dam -W4 4 [102]1 nternal Water Dam -XJ Vertical Expansion Joint (See Z190) -84 Stainless Steel Perforated Gravel Guard -85 Stainless Steel Perforated Extension -89 2 [51] High External Water Dam
(Replaces Internal Dam)
DATE: 08/09/1 2 C.N. NO. 124643
DWG. NO. 67201 PRODUCT NO. Z163 ZURN INDUSTRIES, LLC . • SPECIFICATION DRAINAGE OPERATION . 1801 Pittsburgh Ave. + Erie, PA 16514
Phone: 814/455-0921 + Fax: 814/454-7929 • World Wide Web: lNWW.zurn.com In Canada: ZURN INDUSTRIES LIMITED ~ 3544 Nashua Drive + Miss issauga, Ontario L4V1L2 + Phone: 905/405-8272 Fax: 905/405-1292
Intentionally blank
SPECIFICATION SHEET
99 DOWNSPOUT NOZZLE
TAG OSf\J-/
Dimensional Data (inches and [ mm ]) are Subject to Manufacturing Tolerances and Change Without Notice
c I----C -0-
1----.-
-c-- ;z:,
iil
0B I' \0 0F A of A --
~ II li~ II;
~ , ----
(H_,-~ I l!J. 2 [51J
f--D~t NO HUB THREADED
A Dimensions in inches Approx.
Pipe Size D F Wt. Lbs. B C
IP NH IP NH [kg]
2 [51] 4-1/2 [114] 2-5/8 [67] 4-1/2 [114] 4-1/2 [114] 2-13/16 [71] 2-3/8 [60] 5 [2] 3 [76] 5-1/2 [140] 2-5/8 [67] 4-1/2 [114] 4-1/2 [114] 3-15/16 [100] 3-3/8 [86] 6 [3] 4 [102] 6-5/8 [102] 2-43/64 [69] 4-1/2 [114] 4-1/2 [114] 4-15/16 [125] 4-3/8[121] 7 [3] 5 [127] 7-5/8 [194] 3-1/16 [78] 4-59/64 [125] 5-15/32 [139] 6-1/16 [154] 5-5/16 [135] 12 [5] 6 [152] 8-5/8 [219] 3-3/32 [79] 4-59/64 [125] 5-15/32 [139] 7-1/8 [181] 6-5/16 [160] 13 [6] 8 [203] 10-5/8 [270] 2-31/32 [75] 4-59/64 [125] 5-25/32 [147] 9-1/8 [232] 8-3/8 [213] 14 [6]
10 [254] 12-5/8 [321] 3-1/2 [89] 5-53/64 [148] 6-5/16 [160] 11-5/32 [283] 10-9/16 [268] 15 [7] 12 [305] 14-5/8 [371] 4-5/64 [1 04] 6-13/32 [163] 6-57/64 [175] 13-5/32 [334] 12-1/2 [318] 18 [8]
ENGINEERING SPECIFICATION: ZURN ZANB 199 Downspout Nozzle, All nickel bronze body, optional threaded or No-Hub inlet and decorative face of wall flange and outlet nozzle.
OPTIONS (Check/specify appropriate options)
PIPE SIZE 2 thru 6,8,10,12 [51 thru 152,203,254,305]
,2 thru 6,8,10,12 [51 thru 152, 203, 254,305] \,
PREFIXES ;'\ ZANB
ZAB ZARB
SUFFIXES
All Nickel Bronze Body' All Polished Bronze Body All Plain Bronze Body
-PVC PVC Connection -SS Removable Stainless Screen
(Specify size/type) OUTLET _"_""_ IP Threaded
NH No-Hub
REV. I DATE: 12/09/10 C.N. NO. 120644
*REGULARL Y FURNISHED UNLESS OTHERWISE SPECIFIED DWG. NO. 58841 PRODUCT NO. Z199
ZURN INDUSTRIES, LLC • SPECIFICATION DRAINAGE OPERATION. 1801 Pittsburgh Ave. + Erie, PA 16514 Phone: 814/455-0921 • Fax: 814/454-7929 • World Wide Web: www.zurn.com
In Canada: ZURN INDUSTRIES LIMITED. 3544 Nashua Drive + Mississauga, Ontario L4V1L2 • Phone: 905/405-8272 Fax: 905/405-1292
Intentionally blank
Z348 SPECIFICATION SHEET
DOME TYPE PLANTING AREA DRAIN TAG PO" l
Dimensional Data (inches and [ mm ]) are Subject to Manufacturing Tolerances and Change Without Notice
~----012 [304J---~
r-----01011 [256J--~
r-----09~ [241J--~
A-Pipe Size Approx. DomeOpen ENGIN EERING SPECIFICATION: ZURN Z348
Inches Wt.
Lbs. [kg]
2-3-4-6 [51-76-102-152] 23 [10]
Area Sq. In. [cm2]
78 [503]
Dome type planting area drain, Dura-Coated cast iron body with bottom outlet complete with combination membrane flashing clamp/gravel guard, low silhouette dome and stainless steel mesh screen over dome.
OPTIONS (Check/specify appropriate options)
PIPE SIZE (Specify size/type) OUTLET 2-3-4-6 [51-76-102-152] 2-3-4-6 [51 -76-102-152] 2-3-4-6 [51-76-102-152] 2-3-4-6 [51-76-102-152] 2-3-4 [51 -76-102]
PREFIXES
IC Inside Caulk IG Inside Gasket IP Threaded NH No-Hub NL Neo-Loc
Z ZB
D.C.C.I Body, Clamping Collar and Dome (4-1/4 [108] Dome Height)** D.C.C.I Body, Clamping Collar and Bronze Dome (3-7/8 [98] Dome Height)*
SUFFIXES -G -SA -TC
Galvanized Cast Iron Stabi lizer Assembly (See Z1 036) Neo-Loc Test Cap Gasket (2 [51]- 4 [102] NL Bottom Outlet Only)
'E' BODY HT. DIM. 5-1/4 [133] 5-1/4 [133] 3-3/4 [95] 5-1 /4 [133] 4-5/8 [117]
REV. E DATE: 2/2111 2 C.N. NO. 122789
*REGULARL Y FURNISHED UNLESS OTHERWISE SPECIFIED DWG. NO. 58979 PRODUCT NO. Z348
ZURN INDUSTRIES, LLC. + SPECIFICATION DRAINAGE OPERATION . 1801 Pittsburgh Ave. + Erie, PA 16514 Phone: 8141455-0921 • Fax: 8141454-7929 • World Wide Web: www.zurn.com
In Canada: ZURN INDUSTRIES LIMITED . 3544 Nashua Drive . Mississauga, Ontario L4V1L2 • Phone: 9051405-8272 Fax: 9051405-1292
Intentionally blank
Top Related