PITS & ACCESSORIES 2-1
www.fultonindustries.com.au
PITS & ACCESSORIES
PART 2 YELLOW SECTION
2-2 PITS & ACCESSORIES
www.fultonindustries.com.au
Contents
PITS & ACCESSORIES
PITS PITS INFO .................................................................................................................................................................................... 3 FIBREGLASS PITS ...................................................................................................................................................................... 4 GLASS REINFORCED CONCRETE PITS ................................................................................................................................... 6 POLYMER CONCRETE PIT ...................................................................................................................................................... 10 EXTRA LARGE POLY PITS ....................................................................................................................................................... 11 TELECOMMUNICATIONS & ELECTRICAL PLASTIC PITS .................................................................................................. 12
VISCOUNT PITS GAS PLASTIC PITS ................................................................................................................................................................... 16 WATER PLASTIC PITS .............................................................................................................................................................. 18 RAIL PLASTIC PITS .................................................................................................................................................................. 20 ROAD PLASTIC PITS ................................................................................................................................................................ 22
ROUND PIT ROUND PLASTIC PITS ............................................................................................................................................................. 24 PIT LID LIFTERS ....................................................................................................................................................................... 25
CABLE MARKERS CABLE MARKER - CONCRETE ................................................................................................................................................ 26 CABLE MARKER - BRASS ......................................................................................................................................................... 27
PITS & ACCESSORIES 2-3
www.fultonindustries.com.au
WHICH ACCESS COVER OR GRATE IS RIGHT FOR YOUR JOB There is some confusion in the marketplace about selection of appropriate Access Covers and Grates for particular applications. It should be noted that there is an Australian Standard (AS3996- 2006) for Access Covers and Grates. The appropriate class for a cover or grate depends upon the place of installation. Some places of installation, relative to class, are outlined in the table below. The selection of the appropriate class is the responsibility of the contractor or purchaser of requested items, if there is any doubt on the typical loads applied to the access covers or grates, a stronger class should be selected. Please refer to the table below for load classifications, which is taken from AS3996-2006.
LOAD CLASSIFICATIONS OF COVERS AND GRATES
CLASS TYPICAL USE NOMINAL WHEEL
LOADING (kg)
SERVICEABILITY DESIGN LOAD
(kN)
ULTIMATE LIMIT STATE DESIGN
LOAD (kN)
A
Area (including footways) accessible only to pedestrians
and pedal cyclists and closed to other traffic (extra-light duty)
330 6.7 10
B
Areas (including footways and light tractor paths) accessible to vehicle (excluding commercial
vehicles) or livestock (light duty)
2670 53 80
C Malls and areas open to slow moving commercial vehicles
(medium duty) 5000 100 150
D Carriageways of roads and areas
open to commercial vehicles (heavy duty)
8000 140 210
E General docks and aircraft
pavements (extra heavy duty - E) 13700 267 400
F Docks and aircraft pavements
subject to high wheel loads (extra heavy duty - F)
20000 400 600
G Docks and aircraft pavements
subject to very high wheel loads (extra heavy duty - G)
30000 600 900
Notes:
1. Nominal wheel loads are given for guidance only. Consideration should be given to the type, size and pneumatic pressure of the load applied.
2. Class B design loads exceed AS5100.2 requirements for footway loading 3. Class D design loads exceed AS5100.2 requirements for a W80 wheel load. 4. Class C units are based on an intermediate load. 5. The serviceability load is set at 2/3 of the ultimate limit state design load. 6. A force of 1kN is approximately equal to the weight of 100kg.
PITS INFO PITS
2-4 PITS & ACCESSORIES
www.fultonindustries.com.au
PITS
CATALOGUE NO. DESCRIPTION
FUP1 FIBREGLASS PIT 310mm x 150mm x 230mm DEEP
AL1 5mm THICK ALUMINIUM TREADPLATE LID TO SUIT FUP1
FUP2 FIBREGLASS PIT 485mm x 220mm x 300mm
AL2 5mm THICK ALUMINIUM TREADPLATE LID TO SUIT FUP2
FUP8 FIBREGLASS PIT 600mm x 400mm x 490mm DEEP
AL8 5mm THICK ALUMINIUM TREADPLATE LID TO SUIT FUP8
FUP9 FIBREGLASS PIT 425mm x 300mm x 295mm DEEP
AL9 5mm THICK ALUMINIUM TREADPLATE LID TO SUIT FUP9
FUP10 FIBREGLASS PIT 800mm x 450mm x 470mm
SL10 8mm THICK STEEL CHEQUERPLATE LID TO SUIT FUP10
FUP11 FIBREGLASS PIT 1200mm x 1200mm x 1200mm DEEP
SL11 8mm THICK STEEL CHEQUERPLATE LID TO SUIT FUP11
FUP12 FIBREGLASS PIT 1500mm x 1500mm x 1400mm DEEP
SL12 8mm THICK STEEL CHEQUERPLATE LID TO SUIT FUP12
FUP13 FIBREGLASS PIT 2000mm x 1500mm x 800mm DEEP
SL13 8mm THICK STEEL CHEQUERPLATE LID TO SUIT FUP13
FUP14 FIBREGLASS PIT 2000mm x 1500mm x 1500mm DEEP
SL14 8mm THICK STEEL CHEQUERPLATE LID TO SUIT FUP14
*The range of Fibreglass Pits from FUP11 through to FUP14 are made with a steel frame, covered with fibreglass panels. Lids are blank and all Pits and Lids are made to order. Please choose the correct pit for your application as these are non-returnable items.
FIBREGLASS PITS
PITS & ACCESSORIES 2-5
www.fultonindustries.com.au
PITS
CONCRETE PITS
2-6 PITS & ACCESSORIES
www.fultonindustries.com.au
PITS PITS
GRCP450/5 & GRCP450/8 - Glass Reinforced Concrete 450mm x 450mm x 500mm depth 450mm x 450mm x 800mm depth
* Heavier Duty lids also available. * All Weights are approximate values. * Galvanised covers also available as ‘Boltdown’ or ‘Z’ Lock Padlock
GLASS REINFORCED CONCRETE PITS
PIT DATA
Description Part No. Weight (kg)
Item A: Glass Reinforced Concrete Pit
GRCP450/5 35
Item B: Glass Reinforced Concrete Pit
GRCP450/8 59
Item C: Riser - 600mm Deep
GRCR450/6 39
Item D: Riser - 300mm Deep
GRCR450/3 24
COVER DATA
Description Part No. Weight
(kg) Class Rating
Item E: Concrete Surround with Gastight Access Cover & Frame, 100mm Thick concrete
surround
GRCCSB450/45 (B for class B)
72 Class B & D
Available
Item F: Solid Top Ductile Iron Cover & GMS Frame
- Watertight GRCIC450/45 39, 60 Class B & C
Item G: Galvanised Mild Steel Cover
GRCGSC450/45B 8 Class B
Item G: Galvanised mild steel cover
GRCGSC450/45C 8 Class C
Item H: Lightweight Glass-Reinforced Concrete
Cover GRCGRC450/45 12 Class A
PITS & ACCESSORIES 2-7
www.fultonindustries.com.au
PITS GLASS REINFORCED CONCRETE PITS
GRCP600/6/5 & GRCP600/6/8 - Glass Reinforced Concrete 600mm x 600mm x 500mm depth 600mm x 600mm x 800mm depth
* Heavier Duty lids also available. * All Weights are approximate values. * Galvanised Steel Covers also available as ‘Boltdown’ or ‘Z’ Lock Padlock
PIT DATA
Description Part No. Weight (kg)
Item A: Glass Reinforced Concrete Pit
GRCP600/6/5 63
Item B: Glass Reinforced Concrete Pit
GRCP600/6/8 96
Item C: Riser - 600mm Deep GRCR600/6/6 52
Item D: Riser - 300mm Deep GRCR600/6/3 32
Item E: Riser - 175mm Deep GRCR600/6/175 29
COVER DATA
Description Part No. Weight
(kg) Class Rating
Item F: Concrete Surround with Gastight Access Cover & Frame, 100mm Thick concrete
surround
GRCCSB600/6 (B for class B)
100, 150
Class B & D
Available
Item G: Solid Top Ductile Iron Cover & GMS Frame -
Watertight GRCIC600/6
Class B & D
Item H: Galvanised Mild Steel Cover
GRCGSC600/6 12 Class B
Item H: Galvanised Mild Steel Cover
GRCGSC600/6C 12 Class C
Item I: Lightweight Glass-Reinforced Concrete Cover
GRCGRC600/6 20 Class A
2-8 PITS & ACCESSORIES
www.fultonindustries.com.au
PITS PITS GLASS REINFORCED CONCRETE PITS GRCP900/9/XX - Glass Reinforced Concrete 900mm x 900mm x 600mm depth 900mm x 900mm x 750mm depth 900mm x 900mm x 900mm depth
* Heavier Duty lids also available. * All Weights are approximate values. * Galvanised Steel Covers also available as ‘Boltdown’ or ‘Z’ Lock Padlock
PIT DATA
Description Part No. Weight (kg)
Item A: Glass Reinforced Concrete Pit
GRCP900/9/6 136
Item A: Glass Reinforced Concrete Pit
GRCP900/9/75 143
Item A: Glass Reinforced Concrete Pit
GRCP900/9/9 150
Item B: Riser - 900mm Deep GRCR900/9/9 135
Item C: Riser - 600mm Deep GRCR900/9/6 92
Item D: Riser - 300mm Deep GRCR900/9/3 49
Item E: Riser - 175mm Deep GRCR900/9/175 37
COVER DATA
Description Part No. Weight
(kg) Class Rating
Item F: Concrete Surround with Gastight Access Cover &
Frame,150mm Thick concrete surround
GRCCSB900/9 (B for class B)
280, 350 Class B & D
Available
Item H: Galvanised Mild Steel Cover (2 – Piece)
GRCGSC900/9 40, 44,
50 Class A,
B, C
Item G: Solid Top Ductile Iron Cover & GMS Frame - Watertight
GRCIC900/9 Class B
& D
PITS & ACCESSORIES 2-9
www.fultonindustries.com.au
PITS GLASS REINFORCED CONCRETE PITS GRCP1200/12/9 - Glass Reinforced Concrete 1200mm x 1200mm x 900mm depth
* Heavier Duty lids also available. * All Weights are approximate values. * Galvanised Steel Covers also available as ‘Boltdown’ or ‘Z’ Lock Padlock
PIT DATA
Description Part No. Weight (kg)
Item A: Glass Reinforced
Concrete Pit GRCP1200/12/9 289
Item B: Riser - 300mm Deep
GRCR12/12/3 94
Item B: Riser 600mm Deep
GRCR12/12/6 143
COVER DATA
Description Part No. Weight
(kg) Class Rating
Item C: Concrete Surround with
Gastight Access Cover & Frame, 200mm Thick
concrete surround
GRCCSB1200/12 (B for class B)
700 Class B, C & D
Available
Item E: Galvanised Mild
Steel Cover (2 – Piece)
GRCGSC1200/12 62, 75,
85 Class A, B & C
2-10 PITS & ACCESSORIES
www.fultonindustries.com.au
PIT DATA
Part No. Dimensions
L x W x D Clear Opening
L x W Weight
(kg)
P30 300 x 300 x 450 22.5
P45 450 x 450 x600 43
P60 600 x 600 x 600 60.5
P96 900 x 600 x 600 81
P90 900 x 900 x 600 135
RISER DATA
Part No. Dimensions
L x W x D Clear Opening
L x W Weight
(kg)
R30 300 x 300 300 13.6
R45 450 x 450 x 300 20
R60 600 x 600 x 300 28
R96 900 x 600 x 300 35
R90 900 x 900 x 300 70
LIDS - GALVANISED CHEQUER PLATE STEEL - CLASS 'A' & 'C'
Part No. Class 'A'
Part No. Class 'C'
Dimensions L x W x D
Weight (kg)
C30A C30C 335 x 335 x 31
C45A C45C 485 x 485 x 48
C60A C60C 635 x 635 x 50
C96A C96C 935 x 635 x 50
C90A C90C 935 x 935 x 65
LIDS - DUCTILE IRON COVERS - SOLID TOP - CLASS 'B' & 'D'
Part No. Class 'B'
Part No. Class 'D’
Dimensions L x W x D
Weight (kg)
A30SB A30SD 335 x 335 x 31
A45SB A45SD 485 x 485 x 48
A60SB A60SD 635 x 635 x 50
A96SB A96SD 935 x 935 x 50
A90SB A90SD 935 x 935 x 65
* RECESSED DUCTILE IRON COVERS IN CLASS ‘B’ & CLASS ‘D’ ALSO AVAILABLE
POLYMER CONCRETE PIT PITS
PITS & ACCESSORIES 2-11
www.fultonindustries.com.au
PITS
900 x 600
900 x 900
EXTRA LARGE POLY PITS
PRODUCT CODE
DESCRIPTION MASS (kg)
STORMWATER PITS – 900 x 600
97967 900 x 600 POLYMER STORMWATER PIT CASE ONLY 30
15145 900 x 600 GALVANISED STEEL GRATE ONLY CLASS B 55
97981 900 x 600 POLYMER STORMWATER PIT WITH GALVANISED 85
STORMWATER PITS – 900 x 900
97965 900 x 900 POLYMER STORMWATER PIT CASE ONLY 43
15146 900 x 900 GALVANISED STEEL GRATE ONLY CLASS B 74
97980 900 x 900 POLYMER STORMWATER PIT WITH GALVANISED
STEEL GRATE CLASS B 117
2-12 PITS & ACCESSORIES
www.fultonindustries.com.au
PITS
TELECOMMUNICATIONS & ELECTRICAL PLASTIC PITS
PRODUCT CODE
DESCRIPTION
INTERNAL DIMENSIONS EXTERNAL DIMENSIONS CAPACITY
(L) WEIGHT
(kg) CLEAR OPENING
DEPTH OF REBATE
TOP BASE OVERALL HEIGHT
84811 SERIES 300S STORMWATER
PIT CASE ONLY 315 x 315 300 357 x 357 292 x 292 326 26 1.8
84816 SERIES 300D STORMWATER
PIT CASE ONLY 315 x 315 425 357 x 357 292 x 292 452 37 2.3
84221 SERIES 300 STORMWATER
RISER 315 x 315 150 357 x 357 165 14 1.0
80034 SERIES 450S STORMWATER
PIT CASE ONLY 450 x 450 325 565 x 565 435 x 435 383 62 5.6
80001 SERIES 450D STORMWATER
PIT CASE ONLY 450 x 450 450 565 x 565 435 x 435 510 80 8.0
80035 SERIES 450 STORMWATER
PIT RISER 450 x 450 300 565 x 565 300 60 4.8
80010 SERIES 600 STORMWATER
PIT CASE ONLY 600 x 600 600 715 x 715 560 x 560 660 193 14.0
80036 SERIES 600 STORMWATER
PIT RISER 600 x 600 300 715 x 715 300 108 8.8
E300PP E300PPL E300PR
E450PP E450PR
E600PP E600PR
SERIES 300, 450, AND 600 STORMWATER PITS Designed for both commercial and domestic applications, stormwater pits are injection molded in strong, durable, uv resistant polypropylene and are ideal for many trafficable areas when properly installed. stormwater pits provide both an economical and efficient solution for the removal of surface water to comply with AS/NZS 3500-2003. The entire range of polymer stormwater pits can be used with confidence and permit easy installation.
GRATES & COVERS There are a range of grates and covers to suit the stormwater pits from light-weight aluminium for the series 300 to standard galvanised steel drop-in grates in class A, B and D for all sizes. There are also heel friendly galvanised steel grates in class B and stylish, heel friendly EURODESIGN 316 stainless steel for all sizes. Hard-wearing checkerplate covers for the series 450 and 600 are available in standard or lockable and polymer covers are available for series 300 and 450 for applications where the pit is not being used as a drainage inlet.
STORMWATER MANAGEMENT DEVICES Lightweight polymer leaf baskets are available for the series 300 stormwater pit. Trash screens and SQID devices are available for the series 300, 450, & 600 and are designed to be simple placed into position under the standard steel grate to provide an efficient cost effective guard against trash entering the stormwater drains. No modification is needed to existing pits, and no extra work in new installations.
PITS & ACCESSORIES 2-13
www.fultonindustries.com.au
PITS TELECOMMUNICATIONS & ELECTRICAL PLASTIC PITS
Catalogue
No. Description
Weight (kg)
E300PP 300mm x 300 mm x 300mm Deep - Series 300 Pit 1.8
E300PPL 300mm x 300 mm x 450mm Deep - Series 300 Pit - Long 2.3
E300PR 150mm Poly Riser to suit E300PP/E300PPL 1
E300SCLD Light Duty Blank Gal. Steel Lid to suit E300PP/L Pit 4.4
E450PP 450mm x 450mm x 450mm Deep - Series 450 Pit 8
E450PPS 450mm x 450mm x 300mm Deep - Series 450 Pit - Short 6
E450PR 300mm Poly Riser to suit E450PP/E450PPS Pits 2.7
E55CRL 546 x 546mm "Electricity" “Communications” Polymer Concrete Lid
to suit E450PP/S Pit 15.8
E450SCLD Light Duty Blank Gal. Steel Lid to suit E450PP/S Pit 13
E450SCMD Medium Duty Blank Gal. Steel Lid to suit E450PP/S Pit 19
E600PP 600mm x 600mm x 600mm Deep - Series 600 Pit 14
E600PR 300mm Poly Riser to suit E600PP Pit 4.6
E77CRL 690mm x 690mm Light Duty Resin Lid "Elec" "Comm" "Blank" to suit E600PP Pit 21
E600SCLD Light Duty Blank Gal. Steel Lid to suit E600PP Pit 19
E600SCMD Medium Duty Blank Gal. Steel Lid to suit E600PP Pit 34
** SECURITY LIDS AVAILABLE UPON REQUEST ** Pits and Risers are manufactured from polyethylene to 7mm wall thickness *When using these pits in trafficable area, pits must be installed with a concrete collar to fully support the top of the pit. This collar should be a minimum 150mm x 150mm around the top perimeter of the pit. A support brace is available, and when fixed as per instructions, will prevent deformation of the pit during backfill procedures. The support brace can be removed after installation is completed. Consult Appendix A for Installation Instructions.
E450PR RISER
E450SCLD LID
E450PP PIT E450PP PIT
CABLE JOINING PITS – POLYETHYLENE ‘E’ SERIES
2-14 PITS & ACCESSORIES
www.fultonindustries.com.au
PITS TELECOMMUNICATIONS & ELECTRICAL PLASTIC PITS
CABLE JOINING PITS – POLYETHYLENE “T” SERIES
PP01 PIT PP02 PIT PP03 PIT 505 L x 230 W x 408mm H 655 L x 287 W x 574mm H 780 L x 350 W x 625mm H Lid Opening: 475 x 195mm Lid Opening: 615 x 250mm Lid Opening: 735 x 295mm
PP04 PIT PP05 PIT 710 L x 400 W x 830mm H 710 L x 455 W x 635mm H Lid Opening: 650 x 350mm Lid Opening: 650 x 400mm
Catalogue No.
Description Weight
(kg)
PP01 505mm x 230mm x 408mm D Pit 3
CL01E Concrete Lid "Electricity" 470mm x 190mm x 40mm Thick 10
CL01C Concrete Lid "Communications" 470mm x 190mm x 40mm Thick 10
SC01 Drop in gal steel lid 470mm x 190mm x 40mm Thick
PP02 655mm x 287mm x 574mm D Pit 6
CL02E Concrete Lid "Electricity" 610mm x 245mm x 45mm Thick 13
CL02C Concrete Lid "Communications" 610mm x 245mm x 45mm Thick 13
SC02 Drop in gal steel lid 610mm x 245mm x 45mm Thick
PP03 780mm x 350mm x 625mm D Pit 8
CL03E Concrete Lid "Electricity" 725mm x 300mm x 50mm Thick 28
CL03C Concrete Lid "Communications" 725mm x 300mm x 50mm Thick 28
PP04 710mm x 400mm x 830mm D Pit 10
CL04E Concrete Lid "Electricity" 645mm x 345mm x 50mm Thick 27
CL04C Concrete Lid " Communications " 645mm x 345mm x 50mm Thick 27
SC04 Drop in gal steel lid 645mm x 345mm x 50mm Thick
PP05 710mm x 455mm x 635mm D pit 12
CL05E Concrete Lid "Electricity" 650mm x 400mm x 50mm Thick 30
CL05C Concrete Lid "Communications" 650mm x 400mm x 50mm Thick 30
CL05TC Telstra Composite Class ‘B’ Cover Suit PP05 Pit 20
SC05 Drop in gal steel lid 650mm x 400mm x 50mm Thick
** GALVANISED STEEL LIDS & GASKETS AVAILABLE UPON REQUEST ** **TELSTRA & NBN LIDS ALSO AVAILABLE UPON REQUEST**
PITS & ACCESSORIES 2-15
www.fultonindustries.com.au
PITS TELECOMMUNICATIONS & ELECTRICAL PLASTIC PITS
PP06 PIT PP07 PIT
1375 L x 615 W x 685mm H 1020 L x 550 W x 1110mm H Lid Opening: 1315 x 505mm Lid Opening: 960 x 500mm
PP08 PIT PP09 PIT
1375 L x 631 W x 900mm H 2100 L x 610 W x 920mm H Lid Opening: 1315 x 505mm Lid Opening: 1980 x 505mm
Catalogue No.
Description Weight
(kg)
PP06 1375mm x 615mm x 685mm D Pit 40
CL06E Concrete Lid "Electricity" 1315mm x 505mm x 50mm Thick –
Two Part Lid with Bridging Bar ‘T’ Support 83
CL06C Concrete Lid "Communications" 1315mm x 505mm x 50mm Thick –
Two Part Lid with Bridging Bar ‘T’ Support 83
CL06/8/9TC Telstra Composite Class ‘B’ Cover Suits PP06, PP08, & PP09 Pits 25
PP07 1020mm x 550mm x 1110mm D Pit 32
CL07E Concrete Lid "Electricity" 960mm x 500mm x 50mm Thick –
Two Part Lid with Bridging Bar ‘T’ Support 82
CL07C Concrete Lid " Communications" 960mm x 500mm x 50mm Thick –
Two Part Lid with Bridging Bar ‘T’ Support 82
PP08 1375mm x 631mm x 900mm D Pit 50
CL08E Concrete Lid "Electricity" 1315mm x 505mm x 50mm Thick –
Two Part Lid with Bridging Bar ‘T’ Support 83
CL08C Concrete Lid " Communications" 1315mm x 505mm x 50mm Thick –
Two Part Lid with Bridging Bar ‘T’ Support 83
PP09 2100mm x 610mm x 920mm D Pit 118
CL09E Concrete Lid "Electricity" 1980mm x 505mm x 50mm Thick –
Three Part Lid with Bridging Bar ‘T’ Support 192
CL09C Concrete Lid " Communications" 1980mm x 505mm x 50mm Thick –
Three Part Lid with 2 x Bridging Bar ‘T’ Support 192
** RISERS & GASKETS AVAILABLE UPON REQUEST ** **TELSTRA & NBN LIDS ALSO AVAILABLE UPON REQUEST**
Lightweight, easy to handle and install. Pits have specially designed ribbing for in-ground stability and strength. Concrete Lids suitable for pedestrian traffic only. Plastic Expansion Risers Available for PP04, PP05, PP06, & PP08 Pits. Please ensure that Pits ordered are correct and suitable for the job application, as they are supplied on a NO RETURN basis.
2-16 PITS & ACCESSORIES
www.fultonindustries.com.au
VISCOUNT PITS
Catalogue No. PRODUCT A A1 B B1 C C1 C2
UG2030 G3 COLLAR 710 660 550 502 230 70 285
UG2058 SHELF 450 - 230 - 70 - -
GAS PLASTIC PITS
Catalogue No. PRODUCT A A1 A2 A3 B B1 B2 B3 C C1
UG2031 G1 PIT 460 420 320 317 400 367 317 324 350 301
UG2032 G2 PIT 565 510 480 444 455 400 340 310 530 470
UG2032 G3 PIT 715 650 591 570 550 500 441 430 700 648
UG2031 - G1 PIT UG2032 - G2 PIT UG2033 - G3 PIT
UG2030 - G3 COLLAR UG2058 - SHELF TO
SUIT UG2033 - G3 PIT
ALL MEASUREMENTS IN MILLIMETRES
PITS & ACCESSORIES 2-17
www.fultonindustries.com.au
UG2038 - G1 LID CLASS ‘C’ UG2034 - G1 LID UG2350 - G3 LID
LOCKING MECHANISM FOR
G1 & G3 LIDS
UG2041 - G1 “GAS” RESIN LOCKABLE LID
UG2042 - G2 “GAS” RESIN LOCKABLE LID
UG2043 - G3 “GAS” RESIN LOCKABLE LID
UG2055 - G2 “GAS” RESIN LOCKABLE LID FRAME
UG2053 - G3 “GAS” RESIN LOCKABLE LID FRAME
UG2035 - GAS PIT KEY TO SUIT: RESIN LOCKABLE
LIDS
VISCOUNT PITS GAS PLASTIC PITS
Catalogue No. PRODUCT A B C C1
UG2034 G1 LID 418 366 83 44
UG2038 G1 LID CLASS ‘C’ 418 366 83 44
UG2350 G3 LID 650 495 115 50
Catalogue No. PRODUCT A B C
UG2041 G1 “GAS” RESIN LOCKABLE LID 410 360 50
UG2042 G2 “GAS” RESIN LOCKABLE LID 500 400 50
UG2043 G3 “GAS” RESIN LOCKABLE LID 650 500 50
UG2055 G4 “GAS” RESIN LOCKABLE LID FRAME 580 470 110
UG2053 G5 “GAS” RESIN LOCKABLE LID FRAME 715 565 110
ALL MEASUREMENTS IN MILLIMETRES
2-18 PITS & ACCESSORIES
www.fultonindustries.com.au
WA1501 - HYDRANT PIT
WA1520 - COLLARED HYDRANT PIT
WA1504 - RURAL VALVE PIT
WA1500 - 2 LEG PIT
UG2033 - G3 PIT UG2005 - P5 PIT WA1506 - FLUSHING BOX
WATER PLASTIC PITS
Catalogue No. PRODUCT B B1 B2 C C1
WA1501 HYDRANT PIT 430 395 - 425 -
WA1520 COLLARED
HYDRANT PIT 610 395 370 420 93
WA1504 RURAL VALVE PIT 430 398 375 735 85
WA1500 2 LEG PIT 435 398 315 620 90
Catalogue No. PRODUCT A A1 A2 A3 B B1 B2 B3 C C1 C2
UG2033 G3 PIT 700 652 591 570 550 502 441 420 700 648 290
UG2005 P5 PIT 705 650 - - 455 400 330 - 230 581 230
WA1506 FLUSHING BOX 585 545 455 435 375 340 235 320 350 305 -
ALL MEASUREMENTS IN MILLIMETRES
VISCOUNT PITS
PITS & ACCESSORIES 2-19
www.fultonindustries.com.au
UG2300 - P5 LOCKABLE LID WA1507 - FLUSHING BOX LID
VISCOUNT PITS WATER PLASTIC PITS
Catalogue No. PRODUCTS A B C C1
UG2300 P5 LOCKABLE LID 650 397 90 50
UG2350 G3 LID 650 495 115 50
WA1507 FLUSHING BOX LID 545 339 38 -
Catalogue No. PRODUCT A A1 C C1
SEE ABOVE LID 390 308 85 62
UG2350 - G3 LOCKABLE LID
WA1522 SNAP LOCK LID EMBOSSED ‘VALVE’
WA1510 LID EMBOSSED ‘VALVE’
WA1522 ‘VALVE’ SNAP LOCK LID WA1521 ‘HYDRANT’ SNAP LOCK LID UG2026 ‘DANGER ELECTRICITY’ SNAP LOCK LID UG2036 ‘TELECOMMUNICATIONS’ SNAP LOCK LID WA1502 ‘HYDRANT’ LID WA1503 ‘SEWER’ LID WA1505 ‘AIR VALVE’ LID WA1510 ‘VALVE’ LID WA1525 ‘SEWER’ SNAP LOCK LID
THE VRM LIDS COME IN A RANGE OF COLOURS AND EMBOSSED NAMES. CUSTOM MADE PLATES CAN BE PRODUCED TO SUIT BOTH CORPORATE AND SPECIAL APPLICATIONS
ALL MEASUREMENTS IN MILLIMETRES
2-20 PITS & ACCESSORIES
www.fultonindustries.com.au
UG2072 - RAILWAY CABLE TRAY
UG2071 - RAILWAY CABLE TRAY LID
UG2077 - RAILWAY
CABLE TRAY
UG2076 - RAILWAY CABLE TRAY LID
UG2073 - RAILWAY SINGLE SIGNAL BASE
UG2074 - RAILWAY DOUBLE SIGNAL BASE
UG2090 - RAILWAY PLATFORM PIT
VISCOUNT PITS
Catalogue No. PRODUCT A B C
UG2072 RAILWAY CABLE TRAY 2068 450 338
UG2071 RAILWAY CABLE TRAY LID 2070 450 70
UG2076 RAILWAY CABLE TRAY LID 1150 540 350
UG2077 RAILWAY CABLE TRAY 1150 430 75
RAIL PLASTIC PITS
Catalogue No. PRODUCT A A1 B B1 C
UG2073 RAILWAY SINGLE
SIGNAL BASE 1425 1245 1165 995 530
UG2074 RAILWAY DOUBLE
SIGNAL BASE 2440 2165 1120 850 740
Catalogue
No. PRODUCT A A1 B B1 C C1
UG2090 RAILWAY
PLATFORM PIT 1130 950 830 650 700 65
ALL MEASUREMENTS IN MILLIMETRES
PITS & ACCESSORIES 2-21
www.fultonindustries.com.au
UG2075 - RAILWAY PIT
1000mm
LOCKING MECHANISM
UG2070 - LID UG2104 - LOCKABLE LID
UG2550 - ‘SQUARE TO ROUND’ PIT
LOCKING MECHANISM
UG2350 - LOCKABLE LID
UG2078 - RAILWAY TYPE 1 PIT
LID DETAILS
VISCOUNT PITS RAIL PLASTIC PITS
Catalogue No. PRODUCT A A1 A2 B B1 B2 C C1
UG2070 LID 1000mm 1050 - - 1038 - - 50 -
UG2104 LOCKABLE LID 1000mm 1050 - - 1038 - - 50 -
UG2075 RAILWAY PIT 1000mm 1140 1080 - - 1040 - 1215 -
UG2550 ‘SQUARE TO ROUND’
PIT 700 652 593 550 502 443 1180 1123
UG2350 LOCKABLE LID 650 - - 495 - - 115 50
Catalogue No. PRODUCT A B C
UG2078 RAILWAY TYPE 1 PIT & LID 1120 820 960
ALL MEASUREMENTS IN MILLIMETRES
2-22 PITS & ACCESSORIES
www.fultonindustries.com.au
VISCOUNT PITS
ROAD PLASTIC PITS
Catalogue No. PRODUCT A A1 A2 B B1 B2 C C1
UG2080 VicRoads PITS 660 - - 620 - - 1045 -
UG2550 ‘SQUARE TO ROUND’ PIT
700 652 593 550 502 443 1180 1123
UG2350 LOCKABLE LID 650 - - 495 - - 115 50
UG2080 - VIC ROADS PIT
UG2550 - ‘SQUARE TO ROUND’ PIT
LOCKING MECHANISM
UG2350 - LOCKABLE LID
ALL MEASUREMENTS IN MILLIMETRES
PITS & ACCESSORIES 2-23
www.fultonindustries.com.au
VISCOUNT PITS
ROAD PLASTIC PITS
Catalogue No. PRODUCT A A1 A2 B B1 B2 C C1 C2
UG2086 J3 PIT 545 505 449 320 270 220 535 480 250
Catalogue No. PRODUCT A A1 B B1 C C1
UG2081 DETECTOR PIT 248 223 248 233 395 -
UG2082 DETECTOR PIT
LOCKABLE 248 223 248 233 395 -
UG2083 DETECTOR PIT LID 220 - 220 - 45 25
UG2084 DETECTOR PIT LID
LOCKABLE 220 - 220 - 45 25
UG2580 - P5 - 800 PIT UG2086 - J3 PIT
UG2082 - DETECTOR PIT LOCKABLE
UG2084 - DETECTOR LID LOCKABLE
UG2081 - DETECTOR PIT
UG2083 - DETECTOR LID
ALL MEASUREMENTS IN MILLIMETRES
2-24 PITS & ACCESSORIES
www.fultonindustries.com.au
ROUND PIT
CABLE JOINING PITS – POLYETHYLENE ROUND PIT
Catalogue No.
Description Weight (kg)
PRP01 Polyethylene Round Pit Size: ID 300mm x 600mm Deep 6
CRL01 Concrete Lid Round 60mm Thick marked "Electricity" 18
Knockouts – Polyethylene Pit can be supplied with drilled holes 100mm Diameter for Electrical or Communications use.
*ESSENTIAL ENERGY APPROVED PIT / LID / GASKET AVAILABLE ON CODE: PRP01LG ESSENTIAL CODES: 286600 / 114975 / 286658
ROUND PLASTIC PITS
PRP01 LID GASKET Catalogue No. GASPRP01 ESSENTIAL CODE: 286658
PIT LID LIFTER Catalogue No: 02LHFESS “YELLOW SHAFT”
PITS & ACCESSORIES 2-25
www.fultonindustries.com.au
PIT ACCESSORIES
FIBREGLASS PIT LID LIFTER Catalogue No: 02LHFGM “ORANGE SHAFT” FIBREGLASS INSULATED LIFTING KEY, USED FOR LIFTING OF CONCRETE PIT LIDS – TELSTRA TYPE. USED BY THE DEPARTMENT OF QUEENSLAND MAIN ROADS
Catalogue No: LKL Catalogue No: LKS
**NOTE: PIT LID LIFTERS ARE NOT TO BE USED AS A LEVERS **
PIT LID LIFTERS
LIFTING KEYS FOR GASTIGHT ‘GATIC’ ACCESS COVERS
PIT LID LIFTER Catalogue No: 02LHFESS “YELLOW SHAFT” ESSENTIAL ENERGY (Country Energy) APPROVED
2-26 PITS & ACCESSORIES
www.fultonindustries.com.au
CABLE MARKERS
CABLE MARKER - CONCRETE
CATALOGUE NO.
DESCRIPTION WEIGHT
(kg)
CM1-202 CABLE MARKING BRICK WITH SINGLE DIRECTIONAL ARROW SIZE:
202mm x 150mm x 38mm COLOUR: GREY 2.5
CM2-202 CABLE MARKING BRICK WITH DOUBLE DIRECTIONAL ARROW SIZE:
202mm x 150 x 38mm COLOUR: GREY 2.5
CM1220 CEMENT CABLE MARKING SLAB WITH SINGLE DIRECTIONAL ARROW
“CABLE” INSIDE ARROW. COLOUR: CEMENT GREY. SIZE: 200mm x 120mm TOP, 220mm x 140mm BOTTOM, 200mm HIGH
12
CCC100/15 CEMENT – DANGER ELECTRIC MARKING SLAB: SIZE: 1000mm x 150mm 17.5
CCC100/30 CEMENT – DANGER ELECTRIC MARKING SLAB: SIZE: 1000mm x 300mm 35
CCC100/30
CM1-202
CM1220
PITS & ACCESSORIES 2-27
www.fultonindustries.com.au
CABLE MARKERS
CABLE MARKERS
CABLE MARKERS
CABLE MARKERS
** BRASS PLATES CAN BE CUSTOM MADE TO ORDER IN DIFFERENT SIZES & WORDING**
CABLE MARKER - BRASS
CATALOGUE NO.
DESCRIPTION WEIGHT
(kg)
UCM - 2
UNDERGROUND CABLE MARKER CAST IN CORROSION-RESISTANT BRONZE. SUITABLE FOR SETTING INTO CONCRETE FOOTPATH OR
KERBING. RAISED LETTERS PROVIDED LONG TERM APPLICATION SIZE: 117.5mm x 50mm x 7mm THICK WORDING: "DANGER UNDERGROUND
ELECTRIC CABLES". PINS ON THE BACK: 21.5mm LONG
0.33
BPC BRASS PLATE 75mm x 75mm x 1.2mm "COMMUNICATIONS" 0.05
BPE BRASS PLATE 75mm x 75mm x 1.2mm "ELECTRICITY" 0.05
BPE
BPE
BPE
BPE
UCM-2
BPC
2-28 PITS & ACCESSORIES
www.fultonindustries.com.au
THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK
Top Related